Loading…
Loading…
1,291 results • Best match
JJM WATER SUPPLY SCHEME AT AT TEMBRUNBARI TAL YAWAL DIST. JALGAON
SOLAR PUMP Item No.-1Providing and erecting and Testing 2.0 H.P Solar submersible brushless D.C. pump suitable for borewell with all necessary attachment, rate are incluuded , transportation,erecting charges, solar panels & AMC of 5 year on site. As per model 1 MNRE benchmark coast for off-grid and decentralized solar PV system for year 2021-2022 14/08/2021 (7.50 H.P. without USPC) (1200 Wp PV Array)as per order of shobhit Srivastav , Scientist D,32/24/2022-SPV division, GOI, MNRE Date 18-08-2021) Note:- Buy only Grundfos or Lorentz company Solar Pump From the market (Solar Pump 2.0 H.P. DC) installation of Solar Pump at Hilly Area
CONSTRUCTION OF BUILDING FOR ECHS POLYCLINIC TYPE D AT SHERGARH (NON MILITARY STATION) UNDER GE (ARMY) NO. 02 JODHPUR
Supply, installation, testing, and commissioning of a 10 kWp grid-connected rooftop solar PV system utilizing 144-cell Bifacial Mono Crystalline Half-Cut PERC modules rated at 545 Wp per module, coupled with a 10 kWp string inverter for high-efficiency energy conversion. The system includes a robust galvanized iron mounting structure designed to optimize sunlight exposure and withstand wind speeds up to 150 km/h. Additional components include high-quality DC and AC cables, DC and AC distribution boxes with surge protection devices, copper-bonded earthing, lightning arrestors, and ISI-marked UPVC conduits for cable routing. The setup integrates an internet-based remote monitoring system and bi-directional net metering to enable seamless energy management and monitoring. The project ensures compliance with IEC standards, and commissioning support to promote efficient and reliable solar energy generation for long-term sustainability, complete as per below specifications:
Improvements to Hydro mechanical components
Suppling and Fixing of Solar Street light 60 W 2 IN 1 SOLAR STREET LIGHT, 12.8V 54 AH LITHUM FERRO BATTERY, 12 V 200 WATT PANEL AND OTHER ACCESSERIES. complete as per specifications and as per dire...
SH- Providing E.I. fire fighting system solar pole lights CCTV camera networking wi-fi system Lift therein.
Supply & installation of 500 Lpd solar water heater ECT Type Solar SS/GI tank with ceramic coating.58*2100 mm Thermal evocated tubes.5feet ms stand for hot water tank,5.5 feet ms stand for cold water tank. 500 ltr.cold water water tank.3 kv electrical backup system etc. as required complete in all respect and to the best satisfaction of Engineer-in-charge.Make:- TATA, Recold,Superme solar Jain Solar
INSTALLATION OF SOLAR DRINKING WATER TANK AT SANSAD IV SARKARPARA,PART NO-17/151,15TH FC (TIED),ACTIVITY ID-110940246
Power conditioning unit with enclosure: Supply, transportation, Installation and commissioning of Solar Power Conditioning Unit consisting of following components and features 1. Variable frequency Drive with inbuilt MPPT, Voltage range suitable for operation pump-motor set of 1HP to 20 HP, detail mentioned in cl 6.1 2. Power input: DC source for 1HP, 2HP and 3HP 3. Power input: AC/DC source or hybrid for 5HP and above 4. Incomer: DC MCB 2 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 5. Incomer: AC MCB 4 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 6. Type II DC SPD of 40 KA 7. Type II AC SPD 40 KA for AC/DC or Hybrid input 8. Dual input (Solar/Grid) 25 amp changeover switch for 5H and 7.5HP, 40 amp for 10HP, 63 amp for 15 to 20 HP 9. Reverse protection diode 1600 VDC with heat sink 10. Data logger 11. Remote monitoring system 12. Should have built –in EMC filters 13. IP 65 glands for cable in and out 14. Min. IP 54 enclosure. For details features, protection, RMS, communication architecture, security Data storage, tolerance or various parameters, standards to be qualified, etc. please refer to cl. 6.1 of technical qualification. For 1 HP capacity Pump-motor Set with DC input
INSTALLATION OF SOLAR DRINKING WATER TANK AT SANSAD VIII OLD PANDA PARA,PART NO-17/155(TIED),,15TH FC ,ACTIVITY ID-110941500,
Power conditioning unit with enclosure: Supply, transportation, Installation and commissioning of Solar Power Conditioning Unit consisting of following components and features 1. Variable frequency Drive with inbuilt MPPT, Voltage range suitable for operation pump-motor set of 1HP to 20 HP, detail mentioned in cl 6.1 2. Power input: DC source for 1HP, 2HP and 3HP 3. Power input: AC/DC source or hybrid for 5HP and above 4. Incomer: DC MCB 2 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 5. Incomer: AC MCB 4 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 6. Type II DC SPD of 40 KA 7. Type II AC SPD 40 KA for AC/DC or Hybrid input 8. Dual input (Solar/Grid) 25 amp changeover switch for 5H and 7.5HP, 40 amp for 10HP, 63 amp for 15 to 20 HP 9. Reverse protection diode 1600 VDC with heat sink 10. Data logger 11. Remote monitoring system 12. Should have built –in EMC filters 13. IP 65 glands for cable in and out 14. Min. IP 54 enclosure. For details features, protection, RMS, communication architecture, security Data storage, tolerance or various parameters, standards to be qualified, etc. please refer to cl. 6.1 of technical qualification. For 1 HP capacity Pump-motor Set with DC input