Loading…
Loading…
3,622 results • Best match
REPAIR AND MAINTENANCE OF RMU, VCB, TRANSFORMER STREET LIGHT FITTING, LT PANEL AND OTHER CONNECTED WORK AT HEMRL SUTARWADI PASHAN
Supply and fix in replacement Automatic Street Light Switch using NATURE SWITCH for automatic switching of Street Lights based on LUX level of Natural Light. The Sensor (Nature Switch) along with suitable Power Contactor32 Amps, MCB TPN 40 Amps, C curve 10 KA and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54.The Contactor, MCB and Circuit Wiring should suitable enough to take load of 6 kW three-Phase load . compelte all as specified and directed. Make: Swadeep/Havells
High Mast Shifting and Providing Street Light to Sri Jwalamukki Tripura Sundari amma Temple, Uthanahalli Village and Chamundi hill
High Mast Shifting and Providing Street Light to Sri Jwalamukki Tripura Sundari amma Temple, Uthanahalli Village
ward 19 mein kashiram colony ke samne se wet west hote hue power house tak 8 meter pole sahit street light adhishthapan karya.
Supply and fixing of LED Street Light Fitting with mandatory driver set having die cast aluminium body with toughend glass/UV stabilized PC Cover and lenses suitable for 110 watt to 130 Watt and Confirming to IP 66, and IK07 and above protection having Company LOGO Engraved complete in all respect including Labour. [S.R. No. 23.17]
Term contract for external electric supply like DG sets transformers street lights electric poles etc at Sect HQ Khatla Tuikhuatlang
Supplying of LED Ceiling light (round, small, med, large sizes) (supply)
REPAIR/MAINT OF UG CABLE, EARTHING,FEEDER PILLAR BOXES, LT PANEL AND STREET LIGHT AND GARDEN LIGHT SYSTEM AT HQ SNC SANJIVANI, ELLISION AVENUE, NSRY, SNC(O) MESS, NIAT, ASW, COMCEN, SIGNAL SCHOOL AND OTHER AREAS AT NAVAL BASE KOCHI.
(v) Contractor should ensure to rendering completion of all attended complaints to respective JEs/Engr-in Charge as day to day basis . (vi) Attending the fault/complaint and rectification will be on daily basis irrespective of number of complaints. The spare parts/items required for rectification will be measured in the respective item of schedule. (iv) Contractor should ensure all the street lights are functional before leaving the station and rep of contractor should check after all the street lights are switch ON after rendering completion to respective JEs/Engr-in Charge as day to day basis . (v) The Contractor/rep shall check the servicability of all the street lights under the mentioned areas of contract once in a week and inform to JE/AGE. The unservicability of any street light shall be made servicable within two days of complaint report. A penalty of Rs 1000.00 shall be imposed if the unserviciability reported above 25% of total lights. Note : - Contractor has to quote taking the below mentioned points into consideration and the rates of the above items are inclusive of the below mentioned points. (a) The contractor shall be provided Electricians and Helper for minimum 8 Hrs during working hours of Naval Base/ specified by JE/AGE (b) The contractor has to provide additional manpower as per site requirement / as directed by JE/AGE as when required (c) All the Lights / LT cable / Electrical components breakown complaints has to be attended immediately and completed on the same day. (d) Contractor has to note that the complaints will be raised everyday and the contractor staff has to attend the complaints on day to day everyday basis complete for the span of the contract. (e) Contractor has to arrange sufficient labours during major breakdowns as directed by the Engg-in-Charge
1278 - Providing and Fixing Interlocking Paver Blocks, Street lights poles, Boundary wall and other miscellaneous work in Staff Quarter near CIPET Murthal under MC Sonipat
[23.28.13.9]Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 9. 36 watt [Rate]