Loading…
Loading…
3,984 results • Best match
Reconducting at Kungudi DTR With Covered and ABC under electrical section pallickathodu
Dismantling one ordinary street light/CFL/LED fitting from existing pole and refitting the same on newly erected pole including disconnecting and reconnecting wires.
Reconductoring 11KV Korani Feeder and Kalamachal Feeder with Covered Conductor CW-4532- 202526-30 CW-4532-202526-28 under Electrical Section, Avanavancherry of Electrical Division, Attingal under Electrical circle, Thiruvananthapuram
Dismantling one ordinary street light/CFL/LED fitting from existing pole and refitting the same on newly erected pole including disconnecting and reconnecting wires.
Electrical work for Interlocking of 3 nos. of level crossing gates (KA-48, RC-2 & MR-35) where TVU is greater than 10000 over Adra division.
Installation, & commissioning of LED street light CAP- 48W as per site Numbers requrement with the directives of the Railway site Incharge. Details in Expl note.
PROCUREMENT OF MAINT ITEMS
LED Street Light 60 Watt 240 volt IP 66 Item description all as per BOQ specification document uploaded
electrical equipments repairing and light arrangement work at gaushala ground
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED/ integrated lens diffuser & should be High power LED of 3 to 5 watt each . The System efficacy >=125 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current 750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required.
Drawing 11KV Covered Conductor from Palipuzha Transformer to Poovathussery at Electrical Section Annamanada
Dismantling one ordinary street light/CFL/LED fitting from existing pole and refitting the same on newly erected pole including disconnecting and reconnecting wires.