Loading…
Loading…
3,916 results • Best match
GSU/SC: Provision of new crossing station between Kamalnagar and Udgir with standard layout (19km) on Vikarabad-Parli section - Electrical arrangements
Supply of 60W LED street light complete with necessary clamps and hardware etc. as per specification
CONSTRUCTION OF 04 X STORAGE SHED WITH PLINTH AT CSD DEPOT BAREILLY.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
REPAIR / REPLACEMENT OF INTERNAL WIRING WITH FITTING FOR SHED NO 3, 7 AND 11 AT COD MALAD UNDER GE (N) SANTACRUZ, MUMBAI
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with GI bracket min 32mm dia all as specified and as directed by Engr-in-Charge.Make:- Shakti Cat part No SZPSLPM045-SDC / Crompton Cat part No TRP-417-45-57-SL-LM-NBK / Philips Cat part No 9194159200_2(BRP031) as approved by GE
Janpad Hamirpur esthit Nirikshan Bhawan Parisar me Navnirmit 2 Suite va Metting Hall ke Vidhuyatikaran ka karya
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L, N, E as per IEC 61000-4-5, Driver efficiency >85%, THD 10% as per IEC 61000-3-2, P. F. =0. 95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1. 5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 40 watt
PROVISION OF DEFICIENT INFRASTRUCTURE FOR GDT OF HERON MK II AT NAVAL AIR ENCLAVE PORBANDAR
Supply and fixing LED street light fitting 70 Watt, 230 V AC outdoor type with high pressure die aluminium housing and heat resistant complete with driver, lamp, with impact and corrosion resistanct including thermal management in multiple optics, including suitable size mounting bracket, clamps,nut, bolts complete with IP 65/66 protection all as specified and directed by Engr-in-Charge.
Janpad Hamirpur esthit Nirikshan Bhawan Parisar me Navnirmit 2 Suite va Metting Hall ke Vidhuyatikaran ka karya
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L, N, E as per IEC 61000-4-5, Driver efficiency >85%, THD 10% as per IEC 61000-3-2, P. F. =0. 95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1. 5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 40 watt