Loading…
Loading…
3,751 results • Best match
Establishing 2X20 MVA, 110/11kV sub-station at Chalageri and construction of 110kV DC line from existing 110/11kV Aremallapura Substation to proposed 110/11kV Challageri substation using panther conductor for a distance of 18.169kms along with construction of 2 nos of 110kV terminal bays at existing110/11kV Aremallapura sub-station in Ranebennur Taluk, Haveri District
SS139 Supply & Fixing of LED Street light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material LED streetlight 200W. Note:1 No. of Lightning / Lighting Mast (LM) type are proposed for lightning protection and for illumination of the station Yard. The quantity of lightning / lighting mast indicated are located such that the entire station yard with equipments is protected against lightning. However any additional lighting masts may be provided for sufficient illumination and lightning protection (DSLP)of yard, if necessary. The design of lighting outdoor & indoor is also in the scope of the bidder as specified elsewhere in the technical specification. The scope also includes supply & erection of lighting fixtures, lighting mast panels with timer, contactor, control cable, etc. Nos 12 0 12
Upgradation of existing 2x5MVA, 33/11 kV sub-station to 2X20 MVA, 110/11kV sub-station at Mudenur and construction of 110kV DC line using Panther conductor from 110/33/11kV Tumminakatte Sub-station to proposed 110/11kV Mudenur Substation for a distance of 15.656kms along with construction of 2 nos. of 110kV terminal bays at existing 110/33/11 kV Tumminakatte sub-station in Ranebennur Taluk, Haveri District.
SS139 Supply & Fixing of LED Street light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material LED streetlight 200W. Note:1 No. of Lightning / Lighting Mast (LM) type are proposed for lightning protection and for illumination of the station Yard. The quantity of lightning / lighting mast indicated are located such that the entire station yard with equipments is protected against lightning. However any additional lighting masts may be provided for sufficient illumination and lightning protection (DSLP)of yard, if necessary. The design of lighting outdoor & indoor is also in the scope of the bidder as specified elsewhere in the technical specification. The scope also includes supply & erection of lighting fixtures, lighting mast panels with timer, contactor, control cable, etc. Nos 12 0 12
Construction Of Warehouse 510 M.T. and Machinery Shed for Silage and Maka Bharada (278.74 Sq. Mt.)
Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
PROVN OF STORAGE ROOM FOR SAND MODEL HALL AT BUILDING NO - 70 DSSC WELLINGTON
S&F in repair LED street light /security light luminaries fitting 1X30 watt LED with min 120 lumens/watt output including GI bracket made out of GI pipe light grade 25 mm dia 1.20 m long bent to shape with suitable size mild steel clamps of size 50 X 6mm with nut, bolt, & washers as required at site for fixing of street light on LT poles / wall including making connection with PVC insulated 3 single core of 1.5 sqmm size multistranded copper conductor cable complete all as specified and directed.
REPAIR/REPLACEMENT AND MAINTENANCE OF ELECTRICAL WIRING, SUB MAIN WIRING, DISTRIBUTION BOARDS AND MCBs, LIGHT FITTING/FIXTURES INCLUDING MISC ELECTRICAL WORKS AT CERTAIN OTM ACCN OF MIL STN KANCHRAPARA UNDER GE BARRACKPORE
S&F LED street light fitting of high-quality group control enabled integrated LED Bldg Security light with a minimum system lumen of min 4900 lm and system wattage not less than 35W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it's driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including taking down old unserviceable light fitting upto 9 metre height from the normal ground level complete all as specified and as directed.
REPAIR/REPLACEMENT AND MAINTENANCE OF ELECTRICAL WIRING, SUB MAIN WIRING, DISTRIBUTION BOARDS AND MCBs, LIGHT FITTING/FIXTURES INCLUDING MISC ELECTRICAL WORKS AT CERTAIN JCOs and ORs MD ACCN OF MIL STN KANCHRAPARA UNDER GE BARRACKPORE
S&F LED street light fitting of high-quality group control enabled integrated LED Bldg Security light with a minimum system lumen of min 4900 lm and system wattage not less than 35W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it's driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including taking down old unserviceable light fitting upto 9 metre height from the normal ground level complete all as specified and as directed.