Loading…
Loading…
3,611 results • Best match
Installation and Maintanance Work of Street Light in Ward no 13 for 100 street light under Nagar Parishad Triveniganj.
Installation and Maintanance Work of Street Light in Ward no 13 for 100 street light under Nagar Parishad Triveniganj.
In Ward No. 03 Palia, from Surendra Bari house to Lord Shankar temple via Raju Pandit house, interlocking, road and drain construction and street lighting work.
MAINTENANCE OF STREET LIGHTING ON VARIOUS ROADS IN VARIOUS SECTORS AT U.T., CHANDIGARH (REPLACEMENT OF EXISTING BURNT OUT CABLE, SWITCHGEAR, CASTING OF CEMENT COLLAR AND PAINTING OF POLES ON IRB ROAD AT U.T., CHANDIGARH)
DSR 8.13 LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
8525/E8 REPAIR/MAINT OF SOLAR LIGHTS, STREET LIGHTS, GARDEN LIGHTS, PTLs HIGH MAST LIGHTS, DG SET ETC AT MIL STN SHAHJAHANPUR CANTT UNDER GE (EAST) BAREILLY
Taking down existing non functional security/street light fittings from pole/wall/pipe of any type of LED fitting of any wattage for repairing by replacing of the street light including replacement/ unserviceable accessories like SPD,LED Driver etc & refixing the same with & including connecting cable of 3 core PVC sheathed cu wire conductor not less than 4 Sqmm from light fitting to cable loping box & tightening of brackets, clamp by nut, bolts and washer including testing complete all as specified and directed. NOTE : (i) Replacement and fixing of unserviceable component etc required will be measured & paid separately under respective items of this schedule.(ii) Fitting shall be connected with existing electric wire / cable, in case of existing wire / cable found unserviceable same shall be measured and paid in relevent items. (iii) Any type of Ladder or arrangement for dismantling of light from pole/ veh shall be arranged by the contractor for S/L complaints.
REPAIR/REPLACEMENT OF STREET LIGHTS, GARDEN LIGHTS, HIGH MAST LIGHTS AND CONNECTED WORKS IN ZONE B AREA, EAST OF AKBAR ROAD AT NEW CANTT PRAYAGRAJ
Supply, fixing, connecting & testing LED Street Light fitting of 120 Watt, fixture single piece Pressure Die Cast Aluminium Housing (LM6 Alloy) high quality integrated LED Luminaire. Urban Edge LED Street light fixture, rated wattage of 120 Watt, system efficacy>140lm/watt, system lumen: 16800 lm, The luminaire should be of Class B Serviceability. The LED used in the luminaire shall be SMD type only. IP66 & IK10, SDCM5, THD10%, CRI>70 & CCT: 5700K, Protection Class I, Operating temp: +0 to 50 degree C, Ambient temp.: 35Deg. C, Operating voltage of 120-277V (AC) at 50Hz, LED Life(L70B50): 75,000hrs, Inbuilt surge protection of 4KV & External SPD rating of 10KV, Power factor(pf)>0.95, Potted Driver with LED Driver efficacy>85%, complied with IEC 60598, Driver meets IEC61347 & BIS. The luminaire should have Integrated optics to provide a high quality glare free lighting system. Light fixture with HV/LV cut-off options complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 Amps connector and PVC copper cable 2.5 Sqmm 3 core from junction pole box to fitting complete all as specified and directed.
REPAIR / MAINTENANCE OF STREET LIGHT HIGH MAST LIGHT PERIMETER / STREET SECURITY LIGHT AND CONNECTED ITEMS AT MIL STN 39 FAD BHARATPUR
Supply and fixing of Lithium base Energy efficient integrated Solar street light of 30 watt in Aluminium Die casting body ,corrosion resistance,built in high efficiency solar panel and long life lithium ferro phosphate battery with high efficiency microprocessor based charge controlar Automatic dusk to input voltage 12.8 V with minimum 30 AH battery capacity ,Driver efficiency .85%,PV module minimum output capacity 60 W/h Mono itself will be used to sense the ambient light to switch ON/OFF the Lamp from outside from Light fittings and controled from Pole controlling switch,inbuilt MPPT charge controller,IP65,both PIR and fixed dimming available,4500 lumens (at full brightness) with grater than 150 lumen per watt,5700ANSI,,CRI.70,moptical used, Metal core PCB,Low voltage cutoff ,high power LED,wide beam Angle(135/85 degree) with PIR Sensor LED Life 50000 hrs (LM80 cerified LED),weight less than 15 kg with Green/Red indicator with with battery rating 12.8V-BIS standard along with 5 year warranty covered complete all as specified. Make : Orient / Tata PowerShakti fixtures / Phillips