Loading…
Loading…
577 results • Best match
25 Amps, 500 Volt AC, NH Knife Blade
Description :25 Amps, 500 Volt AC, NH Knife Blade Fuse (Din Type), size NH000 with caharacteristic:-gG/g L, breaking capacity 120 KA. confirming to IS: 13703/IEC 60269-2, suitable for 9KVA Transformer 415 outpu t side HRC fuses in underslung HV power panel. Accepted Makes: Siba/EFEN/Ferraz/ETI/Siemens /Bussmann /Schneider/GE /L&T Only as per item No. 7,8,9 of BOM in Annexure-A of EDTS 355 , Rev-1 or latest. [ Warra nty Period: 30 Months after the date of delivery ] ] Consignee SR. SE/E/TL/SYAE/LLH, ER West Bengal 300.00 Numbers
On Line 2 KVA UPS
Description :On Line 2 KVA UPS as per IS:9000 or latest with IGBT- PWM with inbuilt isolation transformer Technology suitable for Single Phase AC Input 160V-260V 50 Hz and Single-Phase AC Output 230V +/- 1%
Procurement of different field instruments
CONTROL TRANSFORMER
2015 maint flt ord
3 Phase REF Transformer For Rectifier
Supplying, Installation, Testing and Commissioning of Equipments for Electrical measurement, Electrical workshop, Electrical Machine and Power System Laboratory at TTAADC Polytechnic Institute, Khumulwng, West Tripura
Power & Power Factor Measurement by CT & PT in Three Phase Circuit Technical specifications: Power Supplies: • AC Power Supply 0-415V AT 4A • Operated on Mains power 415V, 50Hz +10% Digital Meters: • Digital Voltmeter • Digital Ammeter , Digital Wattmeter (Analog), Digital Power Factor Meter Components are mounted on the panels are: • 3 Phase Capacitive Load (Inbuilt) • 3Phase Resistive Load (External) • 3Phase Inductive Load (External) • Emergency Stop • Current Transformer • Potential Transformer Salient Features: • Front panel built with high class insulated Bakelite sheet with Sticker well printed circuits and symbols. • Three Phase Indication through 25mm Indicators • Patch Cords 4mm (Heavy Duty) 1Meter Length. • High Voltage Test Points are Provided With 4mm Safety Sockets • The trainer is housed in Rack Type Channel Extruded Panel • Panel is modular based easy to place and remove the Module. • Short Circuit protection with the MCB. • Size of the trainer set 30” x 24” Scope of Supply: • Electrical Trainer • 3 Phase Auto Transformer • 3 Phase Resistive Load • 3 Phase Inductive Load • 4mm Patch Cords 1Mtr. Length, Potential Transformer
Amplifier to sensor oil circuit to CLW's Spec. No.- CLW/ES/3/0035 (Alt.-H).
Description :Amplifier to sensor oil circuit to CLW's Spec. No.- CLW/ES/3/0035 (Alt.-H). [ Warranty P eriod: 30 Months after the date of delivery ] ] Electic Loco Shed Stores/BKSC, Jharkhand 12.00 Numbers SER Electric Loco Shed Odisha 21.00 Numbers Stores/BNDM, SER Electric Loco Shed Stores/ROU, Odisha 9.00 Numbers SER Consignee Electric Loco Shed Stores/SRC, West Bengal 10.00 Numbers SER Electric Loco Shed Stores/TATA, Jharkhand 10.00 Numbers SER WS Electric Loco Stores/KGP, West Bengal 108.00 Numbers SER UVAM Item ref. ( Item Id :- 2100121 - Pressure Sensor Oil Circuit Transformer and Differential amplifier to Sensor Oil Circuit ) Inspection Stage Inspection Not Required Details