Earthing Resistance screen train Bus, Rating Resistance-10Kilo Ohms +/-10 % , Max. voltage-500 Volt, Max. Current-0.05 Amps, Power 25 Watt as per CLW's Spec. No.-CLW/ES/3/SK-4/0014(Alt.-H) for 3phase locomotives.
Description :Earthing Resistance screen train Bus, Rating Resistance-10Kilo Ohms +/-10 % , Max. vol tage-500 Volt, Max. Current-0.05 Amps, Power 25 Watt as per CLW's Spec. No.-CLW/ES/3/SK-4/0014(Al t.-H) for 3phase locomotives. [ Warranty Period: 30 Months after the date of delivery ] ] Electric Loco Shed Stores/TATA, Jharkhand 100.00 Numbers Consignee SER UVAM Item ref. ( Item Id :- 2100065 - Earthing Resistor of Aux Converter, Earth Fault Detection 415/110V & Control Circuit in SB-1, Harmonic Filter, Screen Train Bus in SB-1. Resistor of Head Light + Dimmer, Maximum Current Relay in SB-1 and Primary Current Transformer. )
Procurement of different field instruments
CONTROL TRANSFORMER
2015 maint flt ord
3 Phase REF Transformer For Rectifier
SPARES FOR REQUIRED FOR ELECTRO TEKNIKA
CURRENT TRANSFORMER 3POINT3 KV GRADE RESIN PART NO NVCBP0042
Supplying, Installation, Testing and Commissioning of Equipments for Electrical measurement, Electrical workshop, Electrical Machine and Power System Laboratory at TTAADC Polytechnic Institute, Khumulwng, West Tripura
Power & Power Factor Measurement by CT & PT in Three Phase Circuit Technical specifications: Power Supplies: • AC Power Supply 0-415V AT 4A • Operated on Mains power 415V, 50Hz +10% Digital Meters: • Digital Voltmeter • Digital Ammeter , Digital Wattmeter (Analog), Digital Power Factor Meter Components are mounted on the panels are: • 3 Phase Capacitive Load (Inbuilt) • 3Phase Resistive Load (External) • 3Phase Inductive Load (External) • Emergency Stop • Current Transformer • Potential Transformer Salient Features: • Front panel built with high class insulated Bakelite sheet with Sticker well printed circuits and symbols. • Three Phase Indication through 25mm Indicators • Patch Cords 4mm (Heavy Duty) 1Meter Length. • High Voltage Test Points are Provided With 4mm Safety Sockets • The trainer is housed in Rack Type Channel Extruded Panel • Panel is modular based easy to place and remove the Module. • Short Circuit protection with the MCB. • Size of the trainer set 30” x 24” Scope of Supply: • Electrical Trainer • 3 Phase Auto Transformer • 3 Phase Resistive Load • 3 Phase Inductive Load • 4mm Patch Cords 1Mtr. Length, Potential Transformer
Amplifier to sensor oil circuit to CLW's Spec. No.- CLW/ES/3/0035 (Alt.-H).
Description :Amplifier to sensor oil circuit to CLW's Spec. No.- CLW/ES/3/0035 (Alt.-H). [ Warranty P eriod: 30 Months after the date of delivery ] ] Electic Loco Shed Stores/BKSC, Jharkhand 12.00 Numbers SER Electric Loco Shed Odisha 21.00 Numbers Stores/BNDM, SER Electric Loco Shed Stores/ROU, Odisha 9.00 Numbers SER Consignee Electric Loco Shed Stores/SRC, West Bengal 10.00 Numbers SER Electric Loco Shed Stores/TATA, Jharkhand 10.00 Numbers SER WS Electric Loco Stores/KGP, West Bengal 108.00 Numbers SER UVAM Item ref. ( Item Id :- 2100121 - Pressure Sensor Oil Circuit Transformer and Differential amplifier to Sensor Oil Circuit ) Inspection Stage Inspection Not Required Details