Loading…
Loading…
603 results • Best match
Procurement of specific Grade of Lubricants
TRANSFORMER OIL As per technical parameter sheet given under ATC
IGBT BASED 3-PHASE DRIVE PROPULSION EQUIPMENT WITH AMC
Description :SUPPLY AND COMMISSIONING OF IGBT BASED 3-PHASE DRIVE PROPULSION EQUIPMENT WITH PHYSICAL MEDIUM i.e. ESD/ EMD/ OFG FOR MULTI - FUNCTIONAL VEHICLE BUS (MVB) AS PER IEC 61375, TERMINAL BRACKET, BUS BAR LINK AND Cu BRAID REQUIRED FOR CONNECTION BETWEEN MAI N TRANSFORMER AND TRACTION CONVERTER, AUXILIARY CONVERTER, INTERFACING CONNECTORS, C ABLES AND CABLE LOOM REQUIRED FOR CONNECTION FROM VCU1/2 TO SB1/2 PANEL. AS PER SPEC. No. i) RDSO/2008/ EL/SPEC/0071, REV. 5 FOR IGBT BASED 3-PHASE DRIVE PROPULSION EQUIPMENT, ii ) CLW/ES/3/0458 ALT. E FOR CONT ROL CABLES, iii) CLW/ES/3/0459 ALT. C FOR SCREENED CABLE, iv) CLW/ES/3/0124 ALT. P. IN ADDITION TO ABOVE DESCRIPTION, THE PROPULSION SYSTEM SHOULD ALS O COMPLY REQUIREMENT MENTIONED IN "SCHEDULE OF REQUIREMENT" (SOR) DOC NO. PLW/EL/PROP ULSION SYSTEM/SOR/002 REV. 02 WITH ANNEXURE A, B , C , D & E [SEPT-25]., COPY ATTACHED WITH TENDER DOCUMENTS. ANNUAL MAINTENANCE FOR THREE (03) YEARS WILL BE AS PER COMPREHENSI VE ANNUAL MAINTENANCE SPECIFICATION NO. CLW/AMC/C-D&D/01 ISSUED IN MARCH 2016. [ Warra nty Period: 72 Months after the date of delivery ] ] Consignee STORES DEPOT 2, PLW Punjab 127.00 Set Inspection Stage Inspection Not Required Details
SUPPLY OF SPARES OF 155MM/45 CAL SOLTAM GUN SYS
ZTM-25111272 TRANSFORMER MAIN B
Accesories for water and electrical work
Transformer Starter assly 30kW
SUPPLY AND FIXING OF ONLINE UPS WITH BATTERY AT KOOTHANALLUR MUNICIPALITY
Performance Parameters: Description of Stores,Online UPS with IGBT-PWM ((Insulated Gate Bipolar Transistor – Pulse Width Modulation) switching technology and maximum 2% Total Harmonic Distortion at Linear Load,Rating (in KVA) - 6,Input Voltage (AC, 50 Hz) Single Phase, 160V - 260V,Output Voltage (AC, 50 Hz),Single Phase, 230V±1%,Construction:,Availability of Inbuilt Isolation Transformer,Yes,Overall Efficiency (in %),Greater than or equal to 90%,Minimum Overload Capacity of Online UPS,120% of Rating in KVA for 10 minutes,Standard Accessories,Input and Output Power Cables, Battery Connecting Cables and Lugs, Battery Rack, Communication Cable, Battery Fuse,Battery/Backup Bank,Type of Battery,SMF-VRLA (Sealed Maintenance Free-Valve Regulated Lead Acid) /Stationary Lead Acid ,atteries,Battery capacity (in Ah),100 (16nos) With Rack and link Accessories ,Features,Standard Protection For Online UPSwith Battery,Under Voltage Protection , Over Voltage Protection, Short Circuit Protection, Over Load Protection, Over Temperature Protection,Online UPS Metering Information,Input and Output Voltage, Output Power, Battery ,Voltage,Online UPS Alarms and Indicators,UPS Status, Battery Charging and Discharging, Overload Voltage, Audible Alarm for Low Battery/Battery Voltage,Type of Mounting of Online UPS Floor Standing,Ingress Protection,IP20,Operating Conditions Operating Temperature Range (Lower Limit),5°C to 10°C Operating Temperature Range (Upper Limit) 45°C to 50°C Minimum Relative Humidity (Non Condensing at 40 deg C) [in %] Warranty And Reports:,Minimum Standard Warranty,1 year Warranty,2 year,Availability of test report from Central Government Lab/ NABL accredited LAB / ILAC accredited LAB to prove conformity of the specification,Yes Agreed to furnish all the test reports and certificates to be buyer on demand Yes
Supply/Installation/ Testing and Commissioning of 20KVA, 3Phase Servo Stabilizer for Health Centre at Main Campus, University of Kashmir
Supply, Installation, Testing and Commissioning of 20KVA servo stabilizer Digital Microcontroller Servo Voltage Stabilizer In-door type with fresh dehydrated oil.With protection, complete in all respects.Technical Specifications of 3 Phase Servo Stabilizer:Capacity : 20 KVA, Type : Un-Balanced 4 wire system( with Buck- Boost Transformer)Method of Cooling : Oil Cooled, Phase : 3 Phase, 4 wire, Frequency :50 Hz, Input Voltage : (P-P) 250-460 (P-P), Output Voltage : 415 V +-1%, Efficiency : 98% at full load, Operation Temperature : 45 Degree Celsius above ambientRelative Humidity : Up to 90%, Correction Speed : Up to 35 V/secNo load current : Less than 1.5% of rated currentBBT : CRGO core material 0.23mm thickness Metering : LCD , Analogue or Digital ( as per requirement), Indication : Indicators for phase failure, over-load and over-voltageControls : Auto/Manual Selector Switch, Increase Decrease Toggle Switch for Manual Operation, Output SwitchProtection : Input High and low cut off, Output High and low cut off, Overload, Short-circuit protection, Time Delay Protection, Class of Insulation : “A”, Fabrication Box Paint : 7 Process Powder Coated, System construction : As per IS 9815Independent Phase Control : Maintain each phase voltage stable irrespective of unbalanced load, Transformer Winding : Copper 99.9% Pure, Duty Cycle : 100%, Container: 14 SWG with Stove enamelled paint, Cable Box : suitable size of cable box with (3 for input, 3 for output and 1 for neutral), Regulator : Toroidal Type, Oil capacity : As requiredPaint : Powder Coated, Color : RAL 7035 (Polyester Powder Coating)System Construction : AS per IS-9815Two years OEM Warranty Period