Loading…
Loading…
2,662 results • Best match
Manufacture, Testing, Supply and Delivery of SCADA compatible Numeric Differential Relays
Manufacture, Testing, Supply & Delivery of SCADA compatible Numeric Differential Relays for 66/11 kV Power Transformers
Meter Cum Protection Box Suitable for 25KVA DTRs
Meter Cum Protection Box Suitable for 25KVA Distribution Transformers
SUPPLY OF 600 NOS BIS MARK EEL2 NEW 11/0.433KV 250KVA COPPER WOUND DTRs THROUGH RATE CONTRACT OF TWO YEARS
DELIVERY SCHEDULE:- - The supply of 250KVA Distribution Transformers against the rate contract of two years shall be made as follows: The delivery of Transformers shall be completed @ 20 % quantity within two months from the date of LOI/ Counter offer and balance quantity @ 20 per month thereafter. However, earlier delivery shall be acceptable as per requirement of SE (MM), UPCL.
Stage Contract for Supply of Key materials required for maintenance of 33/11KV receiving stations along with their Lines under the jurisdiction of STD Bijbehara during the year 2026-27
Transormer Oil as per IS for Power Transformers,CT's,PTs etc
E quotation for seeking firm rates of Plant and Machinery and Materials category items for preperation/amendment of Schedule of Rate for the year 2026.
Power Transformer (with on load Tap changer) Supplying outdoor type copper wound transformer continuously rated for 3Ph, 50 Hz, at full load and temp. rise not exceeding 45 degree C by thermometer in oil and 50 degree C by the resistance in winding after continuous run at full load rating, the transformer should have oil immersed winding having vector group DY11, HT side connected in delta and LT side connected in star with neutral brought out connected to provide separate earthing. The Transformer shall have power terminal arrangement, bushing/ cable end box on HT side and cable end box on LT side. 2Nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. The transformer should have following standard fittings. The OLTC should be suitable for minimum 50 operations per day. Transformer shall be latest manufacturing standards as per amended IS specifications and the load & No load losses shall be limited to the values given below or as per IS or Norms issued by SEB which ever are lower-
CB200CMA Part No NEW CONTROL PANNEL ASSLY WITH 750 MA E L, CB200C1A Part No AUXILLIARY TRANSFORMER CB 200C 1, CB200C3MA Part No EARTH LEAKAGE RELAY 750 MA, CB200C5 Part No TEST MICRO SWITCH, CB200D1 Part No ISOLATOR ON OFF CB 200D 1, CB200D2MA Part No SENSITIVE CBT FOR EL RELAY 750 MA, CB200D12C Part No OUTGOING TERMINAL, CB200BC Part No AIR CIRCUIT BREAKER ASSY WITH C T and INCO, CB200C2 Part No MAGNETIC O L RELAY OIL DASH POT TYPE, CB200B Part No ACB SUB ASSLY TYPE CB 84, CB200B15 Part No SHUNT TRIP COIL UNDER VOLTAGE COIL, CB200C2BN Part No ELECTRONIC OVERLOAD RELAY, CB200B1 Part No FIXED CONTACT, CB200D23 Part No EMERGENCY TRIP RELAY, CB200C9 Part No BRIDGE RECTIFIER, CB200D1C Part No ISOLATOR FIXING PLATE CB 200D 1C
CB200C1A Part No AUXILLIARY TRANSFORMER CB 200C 1