Tender for Prov SOP to LWSS Kanti Mashwa at Village Dimnu by Prov. 11/.4 KV 100 KVA Sub Station and 11 KV HT Line alongwith CT PT unit in Electrical Section Kamrau under ESD Sataun
Tender for Prov SOP to LWSS Kanti Mashwa at Village Dimnu by Prov. 11/.4 KV 100 KVA Sub Station and 11 KV HT Line alongwith CT-PT unit in Electrical Section Kamrau under ESD Sataun .(Item wise detail attached in tender document as per Annexure "A")
E-Tender on partial turnkey basis for providing 11kV HT Line 11/.4 KV 100 KVA S/Stn for prov SOP to LIS Dhang upperli (Pump House near Mangta Plassi) under ESD No-I Nalagarh
Erection, Testing and Commissioing Construction for providing 11kV HT Line & 11/.4 KV 100 KVA S/Stn for prov SOP to LIS Dhang upperli (Pump House near Mangta Plassi) complete in all respect as per direction of Engineer-in-Charge . (Item wise detail attached in tender document as per Annexure "A")
Tender for Permanent restoration of damaged 11 KV HT LT Line at Village Sahargaon, Teer Teltu, Dhamla, Manwa, Khaniyoud, Thandidhar, Kotla Bangi, Leo Nana, Dhan Chukhriya, Jaghed,and S/area Damage due to Heavy Rain/Snow Fall On ESD Rajgarh
E-Tender for Permanent restoration of damaged 11 KV HT < Line at Village:- Sahargaon, Teer Teltu, Dhamla, Manwa, Khaniyoud, Thandidhar, Kotla Bangi, Leo Nana, Dhan Chukhriya, Jaghed,and S/area Damage due to Heavy Rain/Snow Fall On Dated 23/01/2026 & 24/01/2026 under ESD Rajgarh (Ch. to R/M of HT/LT Line under ESD Rajgarh for the Year 2025-26)
Supply survey erection testing and commissioning for creation of three 25 KVA pole mounted substations and HT LT laying at Dhak Numberdarpora Chaupanpora Lower Naikpora Neel B and Neel C for improvement works under scheme PDDSS2021101301 JPDCL Ba
Laying of HT Line with ACSR Weasel Conductor on ST Poles 9 mtr long AT DHAK NUMBERDARPORA W.NO. 6 PYT. DHANMASTA C under scheme code PDDSS2021101301 under the Jurisdiction of Electric Division, JPDCL Batote (Transformers & Poles available at site)
Shifting LT line of AMD DTR for construction of new gate for DC office building Hamirpur in (E) Section Local-I under ESD No-II HPSEBL Hamirpur. T.S. No. 113/2025-26 WBS no. D-25-1712 (ON Turn key Basis)
ERECTION OF LT LINE : Erection of LT Pole structure with Steel Tubular Pole 9 mtr. Long as per latest standard practices /specification of REC / HPSEBL : (including Digging of pit for pole, muffing of pole, erection of poles, refilling of pit & ramming , drilling of holes in pole and X-arm, fixing of X-arm, Shackle Insulators and painting of structure with Redoxide Primer & Aluminium Paint etc.Complete in all respect as per the standard practices / specifications of the REC /HPSEBL.
HED/05/2026-27
ply Part of 11/0.4 KV, 63 KVA Transformer(T.S no334 /2025-26)TProv. Distribution Transformer (Ordinary), 11/0.4 kV, 63 KVA(Supply by HPSEBL 1nos)RProv. Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) (Supply by HPSEBL 2nos)Prov. RCC Muff 2Prov. Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)Prov. Pipe Earthing SetýProv. LT Distribution Panel Box with MS Sheet of 1.6 mm ( 900x800x200 mm ) cubide Box complete with stand etc and Al Busbar (25x6mm)inside .painted /powder coated after primar coating MCCB 160 amp 3P 35kA , ICS =100 % ICU, Kit-Kit 200 Amp for 63 KVA DTR9Prov. LT Cable 3.5 X 120 mm² 1.1 kV XLPE Cable Unarmoured Prov. Energy Meter 3-x, 4 wire CT operated Static Tri- Vector meter with Box (CT-100/5A) Accuracy Class: 0.5S, Category-C, DLMS Compliant for 63 KVA Transformer+Capacitors Bank 415 V, 36+ KVAr for 63 KVA,Supply Part of 11 KV HT Line T.S No/2025-26oProv. Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) with Steel cap & Base Plate)Provided by HPSEBL 2Nos)DProv. (AAAC 7/3.81 mm 80 mm²) mm Conductor(Prov.by HPSEBL0.600 Kms.)HProv. Cross Arm (Channel Iron (100x50x6) Length 1270 mm for single pole(Prov. Stay Wire HT (10 kg. per Stay Set)Prov.G.I.Wire No. 8 SWG in mtr.Tapping Str. Supply Material nProv. Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) with Steel cap & Base PlateProvided by HPSEBL 2Nos)8Prov.Belt set -MS Angle Iron 50x50x6,Length 1800mm x2No.;Prov.X-Bracing set -MS Angle iron 50x50x6,length 2125mmx2noIProv.X-Arm (Horizontal )Ms Channel (100x50x6,Length 2340x2mm2no formationMProv. GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length: 460 mmBProv. GO AB Switch Unit (11kV, 400A, 25 KA) Tripple pole O/D type )Prov. Stay Wire HT (10.0 kg Per Stay Set)×Prov.Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Disc Polymeric,TC, 90 KN ) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)complete for double pole str in all respect.1Supply Part of 3-Phase LT Line(T.s NO :-/2025-26)«Prov. AAAC 7/3.15 (55mm²) {Includes 1 conductor lengths for 3¦ {Neutral conductor including 1% (Sag, Jumpering and wastage}(Prov.by HPSEBL 2.242kMS)Supply by HPSEBL 1.400)0Prov. ST Pole 9 mtr.long .Supply by HPSEBL 6NOS)+Prov. LT Stay Set Stay Wire(i/c Stay Clamp)JProv. stay wire (7/3.15 mm) (6.0 kg Per Stay Set)complete in all respect.LProv. Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/mProv. Spiral PVC SpacerCErection Part of 11/0.4 KV, 63 KVA Transformer (T.S no334 /2025-26)EachmPer/Set%Name of work:- Tender for prov. 11kV HT line & 3ph LT line to proposed 11/0.4kv 63 kva s/stn at village Chandpur near JSV Scheme for shifting domestic load from existing 250kva DTR to newly prop.63kva stn in (E) Section Kungrat UESD HPSEBL Tahliwal .Bid No 05/2026-27 Bid No. HED-05/2025-26$Contract No: Bid No. HED-05/2025-26