Loading…
Loading…
9,972 results • Best match
Maintaining of Water Supply under SM-12. (Re-invite)
Dismantling of defective tube wells by taking out defective sub. Pump set etc. from bore having depth up to 250 feet by doing following works: Lowering & lifting of sub/sets from bore by taking out double flanged GI pipes, submersible P/Set, Cable, cutting of rusted nuts and boltsetc and replacement of damaged D/F GI pipes, cable, defective pump set etc as per site requirement and lowering of sub P/set, sub cable, GI Pipe etc as required, jointing of cable from sub P/Set along with holding of cable with pipes and jointing of D/F pipes etc with nuts bolts and rubber packing etc. The job includes hiring of all T&P, tripod stand, chain pulley block and other material handling equipments, Safety gadgets ad required and consumable material (rubber packing and Nuts bolts) will be arranged by the firm as per site requirement. The other material required during execution will be provided by department.
WATER SUPPLY SCHEME AT MEHELKHEDI TAL YAWAL DIST. JALGAON
sub work:- -- R.C.C E.S.R. CAPACITY 25000 LTR. Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters centre to centre for E.S.R. having capacity 500 m3 & not more than 6 m c/c for E.S.R.having capacity above 500 m3 including excavation in all types of strata, foundation concret, cement plaster with water proofing compound to the inside face of the container including refilling disposing of the surplus stuff within a lead of 50 meters, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design. providing and fixing accessories such as Stainless steel ladder inside and M.S. ladder with G.I. railing outside, C. I. manhole frame and covers water level indicatiors, lightening conductor, G. I. pipe railing around walk way and top slab, providing spiral staire case from ground level to roof level, M.S.Grill gate of 2 Mtrs height with locking arrangement, B.B. masonry chambers for all valves, ventilating shafts, providing and applying three coats of acrylic emulsion with silicon additives paint to the structure including roof slab and epoxy paint to internal surface & anti-termite treatment for underground parts of the structures and giving satisfactory water tightness test as per I.S. code, The job to include painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in-charge. Notes: 1. The design of the structure be in accordance with relevent (I.S.3370 - 1965 or revised) 2. The design shall satisfy the stipulation as per IS 1893-1984 and I.S. 13920/1993 for seismic focrce and I.S.- 11682/1985 for R.C.C. staging of overhead tanks. 3. For design having more than 6 columns, Providing of internal bracing is obligatory,. External bracking is also obligatory. 4.. The entire structure shall be in M 300 mix only. 5. Plain round mild steel bars grade - I confirming to I.S,432 Part-I or high yield strengh deformed bars confirming to I.S. 1786 or I.S. 1139 shall be used, grade-II mild steel bars will not be allowed. 6. Irrespective of the type of foundation proposed in the design, one set of bracing be provided at the gound level. 7. These rates include providing, M.S. ladder for E.S.R's upto 2 lakhs liters capacity and providing sprial staircase for E.S.R. above 2 lakhs liters capacity. 8. Stagging shall have to be designed with stresses of M-250 for ESR. However all RCC construction should be done in M-300 9. These rates are including the cost of uplift pressure if any and entire dewatering during execution. In case of water logging area where water is struck at shallow depth extra provision of dewatering shall be made as per site condition. 10. All condition given in the Member Secretary"s Circular No.MJP/TS-I/350/1668 dt. 2.8.97 and MJP/S-I/350/2127 dt. 13.7.99 shall be strictly followed and additional cost, if any due to these conditions is included in the rates mentioned below. 11.. 75% part rate shall be payable for reinforced cocnrete and plastering items of containers of E.S.R. till satisfactory hydraulic testing for water tightness is given ; and till that work shall be treated as incomplete. 12. The rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet washout overflow and by-pass arrangement. The scope of work, however inclueds cost of erecting, laying and jointing of pipes and valvews including cost of jointing materials upto 5M beyond outer face of outermost column. 13. For ESR upto 500cum capacity C.I.D. double flanged pipes upto 300mm dia shall be provided and C.I.Specials shall be used.For ESR above 500 cum capacity C.I./M.S. pipes assembly with minimum 8mm thick ness up to 500mm dia. And minimum 10mm thickness above 500mm dia can be used with proper anti-corrosive epoxy teratment from inside and outside. 14. Below mentioned rates are for foundation, with individuals footing with bearing capacity of 30 tonnes per square metre. For raft foundations, these rates shall be increased by 7.5% wheresafebearing capacity ( SBC) is 5 M.T. per Sq.m and by 5% where SBC is more than 5 MT/Sqm. and upto 10MT/Sq.m. This percentage of 5% or 7,5% is applicable for estimation of amount of L.S. items ESR for Extra item due to change from individual footing foundation to raft actual increase in concrete and steel quantities be paid as per relevent SSR Item. 15. The rates shall be increase by 30% for brearing piles upto depth of 10m and for further increased in depth by 5M each it shall be increased by another 10% These rates are applicable where raft is not reasible for pile foundation sulfate resistant cement shall only be used. Single pile for the column is not permitted Group of piles shall be designed with pile cap for each column of ESR. 16. These rates are applicable for staging height of 12 M These rates shall be increased or decreased for per metre variation in the staging height as below 12 to 16 M staging 2% per metre 17. Following rates are for seismic zone-III for Zone-IV these rates shall be increased by 5% and for Zone-II, these rates shall be decreased by 5% concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zones plan before estimation and adopt appropriate rates as per actual seismic zones( Seismic maps attached in this C.S.R.) Note:- 1) Conditin from Sr.No.1 to 11 shall form a part and parcel of the tender papers and shall be included in the DTP for works of R.C.C.E.S.R. Note:- 2) Condition from Sr.No.12 to 17 are for estimation purpose only and shall not be appear in the tender. B.C. of Soil 10 MT/ M2 Stagging height = 12 m Total Net Cost of E.S.R.
WATER SUPPLY SCHEME AT WAGHZIRA TAL YAWAL DIST. JALGAON
RCC ESR Item No : - 1 Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters centre to centre for E.S.R. having capacity 500 m3 & not more than 6 m c/c for E.S.R.having capacity above 500 m3 including excavation in all types of strata, foundation concret, cement plaster with water proofing compound to the inside face of the container including refilling disposing of the surplus stuff within a lead of 50 meters, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design. For raft Fundation Increase vate by 7.5% 1. The design of the structure be in accordance with relevent (I.S.3370 - 1965 or revised) 2. For design having more than 6 columns, Providing of internal bracing is obligatory,. External bracking is also obligatory. 3. The entire structure shall be in M/300mix only. 4. Plain round mild steel bars grade - I confirming to I.S,432 Part-I or high yield strengh deformed bars confirming to I.S. 1786 or I.S. 1139 shall be used, grade-II mild steel bars will not be allowed. 5. Irrespective of the type of foundation proposed in the design, one set of bracing be provided at the gound level. 6. These rates include providing, M.S. ladder for E.S.R's upto 2 lakhs liters capacity and providing sprial staircase for E.S.R. above 2 lakhs liters capacity. 7. Stagging shall have to be designed with stresses of M-200 for ESR. However all RCC construction should be done in M-250 8. These rates are including the cost of uplift pressure if any and entire dewatering during execution. In case of water logging area where water is struck at shallow depth extra provision of dewatering shall be made as per site condition. 9. All condition given in the Member Secretary"s Circular No.MJP/TS-I/350/1668 dt. 2.8.97 and MJP/S-I/350/2127 dt. 13.7.99 shall be strictly followed and additional cost, if any due to these conditions is included in the rates mentioned below. 10. 75% part rate shall be payable for reinforced cocnrete and plastering items of containers of E.S.R. till satisfactory hydraulic testing for water tightness is given ; and till that work shall be treated as incomplete. 11. The rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet washout overflow and by-pass arrangement. The scope of work, however inclueds cost of erecting, laying and jointing of pipes and valvews including cost of jointing materials upto 5M beyond outer face of outermost column. 12. For ESR upto 500cum capacity C.I.D. double flanged pipes upto 300mm dia shall be provided and C.I.Specials shall be used.For ESR above 500 cum capacity C.I./M.S. pipes assembly with minimum 8mm thick ness up to 500mm dia. And minimum 10mm thickness above 500mm dia can be used with proper anti-corrosive epoxy teratment from inside and outside. 13.Below mentioned rates are for foundations with individual footing with bearing capacity of 20 tonnes per square metre. For raft foundations, these rates shall be increased by 7.5% where safe bearing capacity (SBC) is 5 MT per sqm and by 5% where SBC is more than 5 MT/sqm and upto 10 MT/sqm. This % of 5% or 7.5% is applicable for estimation of amount of lumpsum item of ESR. For extra item due to change from individual foundation to raft, actual increase in concrete and steel be paid as per relevant DSR item. 14.The rate shall be increased by 30% for bearing piles upto depth of 10 M and for further increased in depth by 5 M each, it shall be increased by another 10%. These rates are applicable where raft is not feasible. For pile foundations sulphate resistant cement shall only be used. Single pile for the column is not permitted, group of piles shall be designed with pile cap for each column of ESR. 15.The rates are applicable for staging height of 12 M. These rates shall be increased or decreased for per metre variation in this staging height as below 12 to 16 M staging - 2% per metre 16 to 20 M staging - 3% per metre 20 M and above - 4% per metre For 17 M staging height, percentage calculation will be like below : 12 to 16 M --- 4 x 2 = 8% 16 & 17 M --- 1 x 3% = 3% Total = 11% For 21 M staging height, percentage calculation will be like below : 12 to 16 M --- 4 x 2 = 8% 16 to 20 M --- 4 x 3% = 12% 20& 21 M --- 1 x 4% = 4% Total = 24% 16. Following rates are for seismic zone III.For zone IV, these rates shall be increased by 5% and for zone II, these rates shall be decreased by 5%. Concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zones plan before estimation and adopt appropriate rates as per actual seismic zones. (Seismic maps attached in this CSR). Capacity of ESR 124000 Lits. Cost of 10000 Litres capacity E.S.R. (for 01 no. ESR) Basic rate Rs. 10.57 per litre upto 150000 L
Please refer BOQ
Providing water supply to different water stressed areas of Gurha and Utterbehani of Vijaypur Sub Division by way of engagement of Tractor water tanker capacity 4 KL , 03 No. trips per day incl. cost of POL , Hire charges inclusive of salary of Drivers , all toll taxes, token and other taxes applicable for 75 days of peak summer season of the year 2026 (Rate to be quoted per trip)
Maintaining water supply by deployment of staff at various BPS in Sec 18 Rohini AC-13.
Maintain Water Supply – To maintain water supply from various booster pumping station (LT installation) as per prevalent schedule in break duty hrs ( Morning & Evening) as per direction of engineer-in-charge by operating all electrical and mechanical equipment, by deploying of semi- skilled, 1 no. in day shift break duty at each site detail of sites is as under:- 1. Paradise apartments Sec-18 Rohini BPS 2. Platinum Apartments Pkt-6 Sec-18 Rohini BPS. 3. Pump House No. 2 Block B Pkt-2 Sec 18 Rohini BPS 4. Pump House No. 3 Block B Pkt-2 Sec 18 Rohini BPS
Supply, Installation, Testing and Commissioning (SITC) of Energy Efficient Centrifugal Pumpsets at Nainital Urban Water Supply Scheme
Rates for SITC of Energy Efficient Centrifugal Pumpsets at Nainital Urban Water Supply Scheme.