Loading…
Loading…
115 results • Latest
Janpad Ballia me srirampur ghat setu ke pahuch marg Shivpur diyer numbari se pranpur Bihar avam Uttar pradesh ki seema par prvesh dwar nirman me prakash vyvstha ka kary
S/F, testing and commissioning of 6 Mtr all in one Solar Intergrated pole system with aesthetically designed road lighting optic luminaire of IP 66 & Integrated Pole 6 mtr. Solar pole Light with 5 year warranty against any manufacturing defects Complete in all respect. 1. System lumen >6000Lm with efficacy of > 140 lm/watt, System wattage shall not be more than 45 W. Life expectancy > 50000 Hr. color temperature 4000 K, standard light profile 6 H 100% + 6 Hr 50%, working temperature-10 to +60, CRI>70 average lighting beam angle 120 degree, housing pressure die cast aluminium with corrosion resistance polyester powder coated, Impact resistance > IK 07, lamp starting time should be not more than 10 seconds, thermal management system should be provided and LED must be mounted on heat conductive sink with sufficient large surface area by means of fins to dissipate the heat to ambient air, Over voltage Protection. 2. Battery capacity minimum 100 Ah, Life PO4, life cycle minimum 2000 @ 90% DOD with IP 68, With minimum backup for Two days @ standard light profile 6 Hr 100 % + 6 Hr 50 % per day.dimension max 3. PV module- Monocrystalline minimum 360 Wp/23Voc Solar cell efficiency minimum 16.4%, 8 site string, total nominal peak power output minimum 360wp, Water proof connectors. 4. Total Aluminum alloy coloumn length 6 mtr. with minimum 20 mm thick reinforceced base plate, or Total column length 6 mtr with lower 2.0 mtr galvanised / powder coated MS Oipe of min 04 mm thick with minimum 12mm thick rainforced based plate, upper 4 mtr. Aluminium alloy to hold solar PV module and Luminiare. 5. Foundation 1:2:4 RCC Cross section: Minimum 2 times size of base plate Deep: Minimum 1/6 times length of pole Foundation Bolt: Minimum 20mm dia and 600mm long 6. Test Report 1. Standard fixture should confirm to applicable IEC 60598-1, IEC 61000-3-2, IEC 61547, LM 79 & LM 80 BIS 2. Test report for LED LM 80(IS-16105), Internal wiring, fiber glass, insulted multistrand wire. 3. Over voltage Protection Declaration of Conformity safety compliance report for charge controller and should be certified as per IEC 60598-1, IEC 61000-3-2, IEC 61547 4. Test report for vertical pole tested for shock & vibration, wind force to meet safety parameters. 5. Battery test report time 3rd party, along with other test reports. IEC 62133:2012, BIS Certification etc. 6. BIS, IEC 61215, IEC 61730 for Solar PV Panel
Civil works related to Maintenance and Repair for roof treatment and Inner side painting of Control Room Building at 400 KV Sub Station Azamgarh
Civil works related to Maintenance and Repair for roof treatment & Inner side painting of Control Room Building at 400 kv Sub Station Azamgarh.
Mobile Storage Compactors (Q3) (3 (3 ))
Mobile Storage Compactors (Q3) (3 (3 ))
Split Air Conditioner, Wall Mount Type (V3) ISI Marked to IS 1391 (Part 2) (Q2) (3 (3 ))
Split Air Conditioner
SETUP OF 08 NOS SMART CLASS IN DISTRICT AMBEDKAR NAGAR UP
DESCRIPTION OF WORK :
Construction work of (G plus 11) Barrack/Hostel for 200 personnel in the police line premises of Distt.-Azamgarh.
Excavation of Foundation- Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.0.00 LVL. TO 1.50 MTR. DSR. No:- 2.8.1