Loading…
Loading…
4,634 results • Latest
Chair for General Purpose (Q2), Composite Office Tables conforming To Is 8126 (V2) (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
Electronics & Hardware Kit (Q3) (3 (3 ))
Termination of 4c x 25 Sq mm CUAR XLPE Cable, Termination of 4c x 2.5 Sq mm CUAR XLPE Cable, Termination of 16 sqmm Copper Flexible Cable, Termination of 25 sqmm Copper Flexible Cable, 100 mm GI Raceway, 150 mm GI Raceway, 300 mm GI Raceway, Fabrications for Cable Tray Support, 900mm Linear Suspended 15 Watt LED, 1200mm Linear Suspended 20 Watt LED, 8FT Linear Suspended 40 Watt LED, 120 Degree Axeon V Connector, 120 Degree Axeon Y Connector, 1.0m Suspension for RCC Ceiling, Trim LED Tube Light 4Ft, Trim LED Tube Light 2Ft, 2x2 LED Fitting 32 to 36 Watt, Down Light Fitting 12 to 15 Watt LED, Recess Mounted Spot Light 1 to 3 Watt, LED Rope Light 5 Watt per Meter, Wall Fan 16 Inch, 250mm Exhaust Fan with Louvers, Ceiling Fan Sweep 1200mm, 80mm Dia GI Electrode 3 Meter Long, 8G GI Wire, 10 sqmm Copper Flexible Cable, 16 sqmm Copper Flexible Cable, Main Lighting and Power 12 Way VTPN DB, 8 Way ETPN DB, 4 Way ETPN DB, UPS IN OUT DB 63 Amps 4 Pole, IP 66 Enclosure for AC Outdoor Units, 4 Pair Cat 6 Shielded Computer Cable, Tag Block 100 Pair, Tag Block 20 Pair, 50 Pair Armoured PVC Cable, Telephone Outlet Box with Top Plate, IP PBX System Cloud Based, Standard Phone, Executive Phone, IP Phone, Krone Connector 60 Pairs, Cat 6 Computer Cable FR, RJ45 Computer Jack Cat6 Modular, 42U Rack with Accessories, 12U Rack with Accessories, Patch Panel, Network Switch 24 Port, Patch Cord 2 Meter, Patch Cord 1 Meter, Existing Smoke Detector Removing and Installation, HDMI Cable 15 Meter, HDMI Cable 20 Meter, 4MP IP Fixed Rugged Dome Camera, 32 Channel NVR with 4 SATA, 24 Port POE Switch with 4 SFP Ports, 32 Inch Flat Screen HD LED Monitor, 4 TB Surveillance Hard Disk, 12U Network Rack with Accessories, 24 Port Loaded Patch Panel, 5 Meter HDMI Cable, 3 Meter HDMI Cable, 1 Meter Patch Cord, PVC Square Junction Box for CCTV, Media Converter, 6 KVA Double Conversion Online UPS, Floor Popup Boxes 8 Module, Removing of Old Conduit, Removing of Old Light Point Wiring, Removing of Old Circuit Wiring, Removing of Old Switch Sockets RJ11 and RJ45, Removing of Cat 6 Cable, Removing and Shifting of Fire Alarm Panel and Smoke Detectors, Removing of Old 6 Way or 8 Way DB, Removing of 2x2 and Linear Light Fixtures, Installation and Testing of Old Light Fixtures, Installation and Testing of Old Power DBs, Removing of Old Power Cables, Removing and Shifting of Old Networking Rack, 20 HP Cooling Only VRF Unit, 4 TR Round Cassette Unit, 0.8 TR 1 Way Cassette Unit Wind Free, 1.0 TR 1 Way Cassette Unit Wind Free, 1.56 TR 1 Way Cassette Unit Wind Free, 2.0 TR 1 Way Cassette Unit Wind Free, Cordless Remote Controller, Cordless Remote Controller for Round Cassette, Y Joints, T Joints, Installation of 20 HP Outdoor Unit, Installation of 4 TR Round Cassette Unit, Installation of 0.8 TR 1 Way Cassette Unit Wind Free, Installation of 1.0 TR 1 Way Cassette Unit Wind Free, Installation of 1.56 TR 1 Way Cassette Unit Wind Free, Installation of 2.0 TR 1 Way Cassette Unit Wind Free, Copper Piping with Nitrile Rubber Insulation, Main Copper Piping for Outdoor to Y Joint, Control and Transmission Cabling 2 Core 1 sqmm, uPVC Insulated Drain Piping 25 mm, GI Cable Tray for Copper Piping and Cables, Refrigerant Gas Topping, Lifting of Units to Site, MS Stand for Outdoor Unit Floor Mounted, Freight and Transportation, Drier Filter, Core Cutting in RCC or Wall, Minor Civil Work for AC, Nitrogen Pressure Testing and Recommissioning 30 HP ODU, Dismantling and Installation of Round Cassette Unit 4 TR, Old VRF Copper Bid Details 2/111 Piping Modification, Old VRF Control Cabling Modification, Old VRF Drain Piping Modification, Old VRF GI Cable Tray Work, Old VRF Gas Topping, Installation of Split AC, Dismantling of Split AC, Installation of Cassette AC, Dismantling of Cassette AC, Copper Piping with Insulation 1.0 to 1.5 TR, Copper Piping with Insulation 2.0 TR, Copper Piping with Insulation 3.0 to 4.0 TR, 4 Core 2.5 sqmm Cable Indoor to Outdoor, Hard uPVC Drain Piping for Split or Cassette, Outdoor Unit Stand for 1.0 to 2.0 TR, Outdoor Unit Stand for 3.0 to 4.0 TR, Jhiri and Minor Civil Work, RCC Demolition and Disposal, Nano Coated Wall Hung Water Closet, Fluoro Polymer Coated Wash Basin with Auto Cock, Fluoro Polymer Coated Urinal, Health Faucet with Flexible Tube and Bracket, CP Brass Two Way Angle Cock, Floor and Wall Tile Dismantling, Vitrified Floor Tiles 800x800mm, Vitrified Floor Tiles 800x1200mm, CP Brass Soap Container with Bracket, Single Lever Shower Mixing Diverter, 20mm Diameter CPVC Pipe, 25mm Diameter CPVC Pipe, 32mm Diameter CPVC Pipe, Rigid PVC Waste Pipe 110mm
150 Watt 6.6 A isola isolating transformers, 300 Watt 6.6 A isolating transformers, 200 Watt 6.6 A isolating transformers, 15 Watt 6.6 A Isolating transformer, electronic convertor 80 Watt 2.5 Amp, Lamp Holder for 200 W, 200 Watt Bi pin PAPI Halogen Lamp, 105 Watt, bi pin pre-focused halogen lamp, 150W bi pin Halogen lamp, 150W bi pin lamp holder, O ring type rubber gasket for elevated fitting, 150W bi pin halogen lamp for Approach Light, Red filter of AMA make PAPI Units, Clear Prism with Prism gasket, O ring type rubber gasket for inset fitting, 2 pole plug Secondary with leed and suitable fixing gland, Orange filter for inset lights, Red filter for inset lights, Green filter for inset lights, Rubber Gasket for base plate, plug and receptacle of type I, class B, 6 sq.mm 5 KV Primary Circuit Cable, 16 sq.mm 5 KV Primary Circuit Cable, Outer Dom for edge Light fitting, Clinometer, impact spanner, SS bolt of M10 x 25 mm
Designing Software (V3) (Q2) MSE Relaxation for Years Of Experience and Turnover Yes | Complete Startup Relaxation for Years Of Experience and Turnover Yes | Complete Document required from seller Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2026/B/7153710 Dated : 28-01-2026 Bid Document 1/8 Number of Auto Extension count 1 Bid to RA enabled No Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 3 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Advisory Bank State Bank of India (%) ePBG Percentage(%) 5.00 ( ) Duration of ePBG required (Months). 3 (a)., EMD & Performance securityshould be in favour of Beneficiary, wherever it is applicable. Beneficiary : The President of India, Regional Director, P& S (Acting through President of India) Directorate Of Purchase And Stores, Department of Atomic Energy, Directorate of Purchase and Stores, PMO (.)