Loading…
Loading…
871 results • Latest
VHF based approaching train warning system (RAKSHAK) in Jodhpur - Phulera Section of Jodhpur Division (As per RDSO Specifications)
A-Jodhpur Division: VHF based approaching train warning system
Improvement of staff quarters under ADEN/HQ/JU
Item Breakup - A-All Items of CPWD-DSR-2023
Supplying 65 mm guage hard stone machine crushed railway track ballast in stacks and loading in to railway ballast hoppers at DIDWANA ballast depot under ADEN/Degana of Jodhpur Division.
A-ALL ITEMS OF USSOR 2021
Electrification work of Defence Lab Road Baggikhana road Jodhpur
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
old sewerage line replacement and new sewerage line laying and road construction work at various places of sardarpura assembly area
Providing Barricading for Trenches using 80 - 100 mm dia Wooden Ballies as vertical post, atleast 1.5m above ground level and atleast 30-45 cm below ground level at a spacing of 3 m. Two rows of PVC Tape (preferabley red in colour) strip barricading horizontal strip securely tied by the vertical members. Vertical members shall be painted in red and white colour. Rate is inclusive removal and cleaning of site complete in all respect.
REPAIR/MAINT OF 33KV NETWORK OTHER ALLIED WORKS INCLUDING IMPROVEMENT OF INFRASTURCTURE AND REPAIR/MAINT/ASSESSMENT CALIBRATION OF HT SWTICH GEARS AT SECTOR D, E AND F AT ARMY AREA JODHPUR UNDER GE (ARMY) NO. 01
Maintenance and complete overhauling /Calibration of 11 KV VCB/RMU rating upto 800 Amp suitable for repturing capacity 350 MVA and remote control switch including dismantling of operating mechanism parts, well cleaning with petrol & CRC-226 and replacing moving parts including reassembling of parts after well cleaning of complete panel board, main bus bar, de-carbonizing all joints bus bar, CTs & PTs and spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete all as specified and directed by Engineer-in-Charge. Notes: (i) Spare parts required for replacement suitable capacity shall be measured and paid separately under respective items (Srl No.5 to 22) of BOQ. (ii) Calibration shall be done by authorised service technician/engineer and test report shall be submit accordingly. (iii) Single RMU each breaker / VCB shall be considered as one Job