Loading…
Loading…
21 results • Latest
Construction of RCC ESR, UGR, Sunken Pump House, CC Road, Compound Wall, Laying of DI CWRM and Distribution Pipeline, External and Internal Electrification and Instrumentation Works with Pumping Arrangement, etc.
Construction of R.C.C Reservoir/ R.C.C ESR Supplying all materials, labour, T& P including design, construction, testing & commisioning of R.C.C Reservoir/ R.C.C ESR and piping arrangement up to 5.0 Running meter from external face, Raft/Pile foundation & Shaft/Column staging including all work such as soil investigation, earth work in excavation, back filling & disposal of earth, RCC & PCC of required grade, centering and shuttering, brick work, painting, finishing, connection pipes valves fitting, expansion joint, mechanical level indicator etc with lead of all materials to site as per the site requirement and as directed by the Engineer-in- Charge
Remedial measures to leakage and damaged structures for treatment and durability enhancement of Drainage Gallery of Lower Indra Irrigation Project
Cleaning & Surface preparation: Cleaning of concrete structure of Dam gallery by deploying expert labour having experience of working on Dam structures with using latest Machines, Tools. and T & P with all safety equipment and necessary arrangements as directed by the Engineer in Charge
Short Term Maintenance Contract (STMC) estimate from Km 90.000 to 145.630 Km of NH- 353 and from Km 0.000 to Km 12.370 of NH-59 in the state of Odisha for the year 2025-26
Grand Total of BOQ I/We agree to execute the above works on the tender premium % above/below the Grand Total of the Project Cost as given in Contract Document.
Provision of Aerosel base fire Extinguisher in the panels and DB of MCH building at SDH Khariar campus in the district of Nuapada.
Supply & Installation of 8 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.008 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Genefire/Stat-x/Equivalent
Provision of Aerosel base fire Extinguisher in the panels and DB of MCH building at DHH Nuapada campus in the district of Nuapada.
Supply & Installation of 8 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.008 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Genefire/Stat-x/Equivalent
Supply,Installation,Testing and Commissioning of 250 Watt LED Sports Light Fittings and 100 Watt LED Street Light fitting in side Multipurpose Hall at Khariar Road in the district of Nuapada for the year 2025-26.
Supply,Installation,Testing & Commissioning of 250 watt LED Flood light (Sports Light) fittings with non corrosive,high pressure die cast aluminium with UV resistnce lense,having efficiency of 120 LPW,CRI >80,50000 BH as per L70B50, CCT-5700K,IP66,IK 08 protected,4KV internal, 10 KV external surge protection,integral isolated, potted driver with IP66 protection,Driver should withstand high voltage upto 440Volt AC for 8 hours,driver should be vibration proof universal,Life of driver should be > 5 years, exxternal spd of 10 kv provided inside the housing for further surge protection which increase the relibility of the product in long run.Wrranty should be 3 years. Make:-Philips/ Bajaj/Havells.