Tender description: ITB for the construction of, Veterinary clinic in Red Sea State, Eastern Sudan, in Sudan ----- The United Nations Office for Project Services (hereinafter referred to as UNOPS) is pleased to invite competent Bidders/Contractors to submit their respective competitive bids for the ITB for the construction of, Veterinary clinic in Red Sea State, Eastern Sudan- (5) Five Veterinary clinics in accordance with the UNOPS General Conditions of Contract. ----- IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
321566
ITB/2026/65359
Invitation to bid
Sudan
INVITATION
UTC
21 Nov 2026
6 Nov 2026
United Nations Office for Project Services
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
Tender Reference:
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR),
CONSTRUCTION WORKS FOR VETERNARY PROJECT
BILL OF QUANTITIES (BOQ)
- Bill Nr.1 - Mobilization
- Bill Nr.2 to 10-Civil, Electrical & Sanitary Works-BoQ
- Bill Nr.10 - Day Works
NOTE: It is a MANDATORY requirement for bidders to complete and return both this excel BOQs and their respective duly signed pdf for further reference
Failure to complete all sections of the BOQ may result to automatic disqualification of your bid.
PREAMBLE TO BILLS OF QUANTITIES
1 Priliminary Condition
1.1 This Specification shall be read in conjunction with the Particular Technical Specifications provided under each work discipline, as well as the latest edition of the Sudan Standard Technical Specifications for Building Works, or any other internationally recognized standards commonly adopted in Sudan.
1.2 The Bill of Quantities (BoQ) shall be measured in accordance with the latest edition of the Sudan Standard Methods of Measurement for Building Works.Pro Memoria (PM): Indicates that the cost of the item is deemed to be included and distributed within other related work items in the BoQ. No separate payment will be made.Lump Sum (LS): Indicates that the item is priced as a fixed total amount, with no adjustment or variation permitted to the total price regardless of actual quantities executed.
1.3 The contractor has fully understood the scope of works by minutely having studied the drawings and Bill of Quantities with specifications, and by having visited the site. He will, on his own initiative and before the works start and in his best ability, notify the consultant of works which are not mentioned in the BoQ and/or the specifications and/or the drawings, which are necessary to execute the construction as envisioned in the drawings. Thus, after the works have started, the contractor cannot rely on incompletions in the consultants' work to make claims of any kind. Indeed, the contractor will add upon the specifications according to his own insight and professional experience. If there are works to be done which are not specified in this BoQ, it is up to the consultant to decide wether these works are variation works which need change orders, or wether these works are included in the items and their prices in the BoQ.
1.4 The contractor has to execute all works which have a direct or indirect impact on safety and availability of infrastructure (water, sewage, electricity, …) in as short a period as feasible.
1.5 The contractor will secure the structural and functional integrity of the exsiting buildings nearby the project site during construction work as well as of the building’s surroundings such as but not limited to public road, gate, lawn. He will study and execute the necessary scaffolding to support the building, in order to avoid any cracks, settlements, or crumbling. This scaffolding to support the building during the works are included in the prices given. Debris will be cart away to certified debris places in the area. In no way, debris will be stored, buried or burned on site.
1.6 After the works, the contractor will do a thorough cleaning of the construction site, this means cleaning of all excess mortars, cement bags, excess blockwork, excess tile jointing – in short any construction remnant which hinders the proper use of the house upon site hand-over.
NHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
1.7 In general the contractor will put his professional experience and craftsmanship to work, in order to get a holistically well-constructed building, to the highest and most up-to-date standards of Sudan Construction & international Culture.
2 Organisation of Construction Site
This includes all necessary preparations to execute the works; at least from the beginning until the end of the works; according to the best knowledge and experience of the contractor: at least conform local standards.
The objectives of the Bill of Quantities are
(a) to provide sufficient information on the quantities of Works to be performed to enable bids to be prepared efficiently and accurately; and
(b) when a Contract has been entered into, to provide a priced Bill of Quantities for use in the periodic valuation of Works executed.
In order to attain these objectives, Works have been itemized in the Bill of Quantities in sufficient detail to distinguish between the different classes of Works, or between Works of the same nature carried out in differently or in other circumstances which may give rise to different considerations of cost.
4 The Bills of Quantities for the Works comprise the following:
Preamble to Bill of Quantities
List of principal Quantities
Bill Nr. 1 Mobilization
Bill Nr. 2 - 9 Civil, Electrical Installation & Sanitary Installation
Bill Nr. 18 Day Works
5 The Contractor’s unit rates in these bills are to cover supplying of materials, taking delivery, transporting, loading and off loading inspection, storage, stacking, landing, preparation, installation including provision of all labour, requirement false work, temporary support, surface preparation and testing of the works. The rates shall include all applicable taxes and duty. The cost of testing of the materials to be used in the works unless otherwise provided is to be included in the rates of the respective Bill items.
6 Measurement for payment shall be for the complete installation and having passed all necessary tests.
7 Work shall not be executed on a Day work basis unless ordered in writing by the Consultant on approval by the Employer. The rates entered in the Day works Bill of Quantities shall apply to any quantity of Day work instructed by the Consultant. Nominal quantities have been indicated against each item to permit the extended total to be carried forward to the Grand Summary.
8 “Rates and prices shall be inserted in the rate and total columns of the Bill of Quantities in USD
9 Bills of Quantities are to be read in conjunction with the Instructions to Bidders, the Conditions of Contract Data, the Specifications and the Drawings. The quantities stated against each item in the Bills of Quantities, with the exception of those items specifically marked ‘sum’, are the estimated quantities of the Work to be executed by the Contractor in fulfillment of his obligations under the Contract.
10 The Contractor is required to check the number of the pages and should any be found to be missing or in duplicate he must inform the Engineer at once and have the same rectified.
11 No liability whatever will be admitted or claim allowed in respect of errors in the Contractor’s tender due to mistakes in the Bills of Quantities which should have been rectified in the manner described above.
12 The contractor shall not alter or otherwise qualify the text of these Bills of Quantities. Any alteration or qualification made without authority will be ignored and the text of the Bills of Quantities as printed will be adhered to.
13 Each item in the Bills of Quantities is to be priced. If any items are left un-priced it will be assumed that the value of the work described there under is elsewhere allowed for. The prices and rates to be inserted in the Bills of Quantities are to be fully inclusive of all costs and expenses which may be required for the construction of the work described, together with general risks, liabilities and obligations set forth or implied in these documents.
14 In no case will any claim for expenses incurred by the Contractor in preparation of this Tender be allowed.
15 The Contractor is solely responsible for the accurate ordering of materials in accordance with the Specifications, Drawings and Engineer’s Instructions and no claim for any loss or expense will be entertained for orders for materials based on the Bills of Quantities.
16 The quantities given in the Bills of Quantities are estimated and no claim by the Contractor for the final quantities being larger or smaller than the quantities given in the Bills of Quantities will be permitted except alows in accordance with the particular of the Conditions of Contract.
17 The dimensions given in the Drawings are generally in millimeters unless otherwise indicated. Levels are given in meters.
18 The term ‘provide’ or ‘supply’ used for any item shall be deemed to include transport to site, handling, storage and fixing complete, and the Bidder’s rate shall include for this.
19 The following abbreviations have been used in the Bills of Quantities:-
ml metre linear
m2 square metre
PS provisional Sum
Set Complete set of work with accessories & components
lot Complete set of work with accessories & components
PS provisional Sum
USD United States Dollar
uPVC un-plasticized poly vinyl chloride
HDPE high density polyethylene
GMS galvanized mild steel
PPE personal protective equipment
ASTM American society for testing & material
GW well-graded gravel
GP poorly-graded gravel
GM silty gravel, gravel-sand-silt mixtures
GC Clayey gravels, gravel sand-clay mixtures
SW well graded sands
SP poorly graded sands
SM silty sand, sand -silt-mixtures
SC clayey sands, sand-clay mixtures
AASHO American Association of State Highway and Transportation Officials,
ACI American Concrete Institue
RHS rectangular hollow section
PVD Physical Vapor Deposition
HCB hollow concret block
CBR california bearing ratio
MC medium curing
SDB sub distribution board
PDB pump distrbution board
20 Unless otherwise provided there are no separate measurement items for Contractual requirements. The Contractor is deemed to have included his costs for the Contractual requirement
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
PORT SUDAN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
GRAND SUMMARY Amount in USD
1 Bill Nr.1 - Mobilization USD 0.00
2 Bill Nr.2 -Model Veternary Building-
2.1 - Civil Work USD 0.00
2.2 - Electrical Installation Work USD 0.00
2.3 -Sanitaryl Installation Work USD 0.00
3 Bill Nr.3 - Solar PV USD 0.00
4 Bill Nr.4 Pump Control Swith Shed with platform-Civil Work USD 0.00
5 Bill Nr.5 Septic Tank & Soak Away Pit-Civil Work USD 0.00
6 Bill Nr.6 Cattle Waste Holding Tank-Civil Work USD 0.00
7 Bill Nr.7 Site Works-Civil USD 0.00
8 Bill Nr.8 Site Work-Electrical USD 0.00
9 Bill Nr.9 Site Work-Sanitary USD 0.00
10 Bill Nr.10 Signage USD 0.00
GRAND TOTAL USD 0.00
11 Bill Nr.11 - Day Works USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
PORT SUDAN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill Nr. 1- Moblization
1 SIGN BOARD USD 0.00
2 SITE SUPERVISOR TRANSPORTATION USD 0.00
3 SAFTEY HARNESS & PROTECTION USD 0.00
4 SAFTEY & SECURITY OF WORKS USD 0.00
5 SHOP DRAWINGS USD 0.00
6 Existing Condition/Demolishing Work USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 Contractor to provide a Project Identification sign size (200 cm × 200 cm), Contractor to submit shop drawing for UNOPS Engineer Approval, also 2 safety signs (120 cm x 120 cm). Saftey signed to be submitted to approval of Engineers. LS 1.00 0.00
2 Site Supervisor Office & Transportation
2.1 Providing offfice for supervion team completed with office Desk LS 1.00 0.00
3 Saftey Harness and Protection
3.1 2 No (Minimum) Safety Harness with lanyards , 3 fire powder 6Kg fire extinguishers, and selection of gloves & safety glasses to be kept in UNOPS Office at all time, also contractor should in his price include the cost of providing all his staff and work force with suitable PPEs ( i.e. Hard Hat, Safety Boot, Dust Masks, Safety Vests and Safety Glasses) Ls 1.00 0.00
4 Safety & Security of Works
4.1 Allow for providing safety and security for the Works and material as per the requirement laid under the Contract, including security lighting, lockable or open material storage areas, engaging security guards and / or any other measures as necessary. Cost shall include Road Safety awareness, and public traffic flow management during construction. LS 1.00 0.00
4.2 Providing, erecting, maintaining, and removing temporary site hoarding/fence made of corrugated iron sheets (C.I.S.) securely fixed to eucalyptus posts, including all posts, bracing, fixing materials, excavation, installation, maintenance, dismantling, and disposal upon completion. The hoarding shall be approximately 2.4 m high and installed along the site perimeter adjacent to the public road and other accessible areas, as directed by the Engineer, to prevent unauthorized access and ensure site security. ml 93.00 0.00
5 Shop Drawings
5.1 Allow for prepare and submit to the Engineer's Representative a complete set of Shop Drawings, as required to the specified scale(s), giving all details, as required by the Engineer's Representative, for the work executed. Submission shall be in 3 sets as hard copies, colour printed on A1 size paper and 01 set of soft copies in AutoCAD compatible version in a compact disc. LS 1.00 0.00
6 Existing Condition/Demolishing
6.1 Demolishing
The work shall be performed by qualified personnel who have ample experience in demolishing and safety work in order to avoid risk in the existing structure and in human life. Any useful dismantled materials shall be kept in proper manner and submitted to the client after proper cleaning. The contractor shall take all the responsibility of worker discipline in order to avoid disturbance and security issues at the work place and the entire compound. The contractor shall protect the existing area with approved standard plastic or other protective cover. Contractor is advised to investigate the scope of dismantling work before filling in prices.
The rate shall include breaking, cutting, dismantling, loading, hauling and disposal of all demolished materials, debris and unsuitable materials to an approved disposal area designated by the Engineer/Employer, including all labor, tools, plant, equipment, lifting and hauling facilities, water, temporary works, protection of adjacent structures and services, dust suppression, cleaning of the site, and all other incidental works necessary to complete the demolition safely and entirely in accordance with the drawings, specifications and Engineer’s instructions.
The contractor shall take all necessary precautions to prevent damage to adjacent buildings, utilities, pavements and other retained structures. Salvageable materials, if any, shall be separated and handed over to the Employer as directed by the Engineer. The area shall be left safe, clean, level and ready for subsequent construction works. The contractor shall submit methodology and work plan for approval by the Engineer before commencing the Works. contractor is advised to go through the detail of the building structure during pre-bid site visit.
A Demolition and complete removal of the Existing Building “D” as identified in the Architectural Drawing Legend, having a single story built up dimension of 4,000 mm × 4,750 mm and an average height of 2.80 m, comprising one store & pharmacy rooms. The work shall include, but not be limited to, all necessary preparation, protection, temporary support and safety measures; dismantling and demolition of approximately four (4) reinforced concrete columns, grade beams, roof/tie beams and associated reinforced concrete footings extending to approximately 1.50 m below existing ground level; demolition and removal of all HCB external envelope and internal partition walls; dismantling of the eucalyptus timber roof structure and removal of corrugated iron sheet (C.I.S.) roof covering; removal of all existing metal doors, windows, frames, fixtures and other associated building elements such as disconnecting electrical & sanitary system. Ls 1.00 0.00
B Demolition and complete removal of the existing wire mesh perimeter fence, comprising RHS steel structural framing with vertical supports spaced at approximately 4.00 m c/c and three (3) horizontal RHS support members between vertical posts. Each vertical support shall be dismantled and removed together with its approximately 400 × 400 × 500 mm reinforced/plain concrete foundation pad, including any embedded steelwork, fixing plates, bolts, ties and associated components. ml 57.00 0.00
6.2 Saw cutting and preparation of existing asphalt pavement at the interface with new entrance gate interlocking pavment, including straight-line cutting to full asphalt depth, removal of loose and deteriorated material, thorough cleaning by air compressor, application of concrete edge restrain, and proper bonding of new interlocking pavment to existing pavement to form a smooth, watertight, and durable joint, all complete as directed by the Engineer. Rate shall include all labor, materials, equipment, tack coat, cutting tools, compaction, protection of adjacent works, and all incidental works necessary to achieve a seamless transition between existing and new pavment surfaces. Ml 4.00 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
PORT SUDAN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.1- Veternary Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 GLAZING USD 0.00
8 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 294.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 75.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 202.00 0.00
1.4 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 23.00 0.00
1.5 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 126.00 0.00
1.6 Ditto as above item 1.5 but around isolated footing. m3 188.00 0.00
1.7 Ditto as above item 1.5 but around masonry foundation wall. m3 12.00 0.00
1.8 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 391.00 0.00
1.9 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 177.00 0.00
1.10 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 217.00 0.00
1.11 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 104.00 0.00
2.1.2 Under masonry foundation wall m2 47.00 0.00
2.1.3 Under grade beam m2 22.00 0.00
2.1.4 Under slab on grade including ramp & outdoor treatment m2 177.00 0.00
2.1.5 Under masonry steps on grade m2 2.00 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 39.00 0.00
2.2.2 In foundation column. m3 4.00 0.00
2.2.3 In grade beams. m3 15.00 0.00
2.2.4 In 15 cm thick ground floor slab including ramps & outdoor tratment. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 177.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 55.00 0.00
2.3.2 To foundation column m2 45.00 0.00
2.3.3 To grade beams & ramps edge m2 155.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 8 mm deformed bar Kg 17.00 0.00
Dia 10 mm deformed bar Kg 53.00 0.00
Dia 12 mm deformed bar Kg 2,117.00 0.00
Dia 14 mm deformed bar Kg 819.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 244.00 0.00
Dia 14 mm deformed bar Kg 170.00 0.00
Dia 16 mm deformed bar Kg 818.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 327.00 0.00
Dia 14 mm deformed bar Kg 331.00 0.00
Dia 16 mm deformed bar Kg 1,020.00 0.00
2.4.4 For floor slab on grade, ramp slab & outdoor tratment slab
Dia 8 mm deformed bar Kg 648.00 0.00
Dia 10 mm deformed bar Kg 173.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 46.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 2.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 8.60 0.00
1.1.2 In top tie beams m3 10.60 0.00
1.1.3 In water tanker slab with beams m3 1.20 0.00
1.1.4 In lintel beams including roof vent windows m3 0.30 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 91.00 0.00
1.2.2 To top tie beams m2 108.00 0.00
1.2.3 To water tank slab with tie beam m2 9.00 0.00
1.2.4 To lintel beams including for roof vent windows m2 3.00 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 182.00 0.00
Dia 16 mm deformed bar Kg 812.00 0.00
1.3.2 For top tie beam
Dia 8 mm deformed bar Kg 270.00 0.00
Dia 14 mm deformed bar Kg 294.00 0.00
Dia 16 mm deformed bar Kg 1,101.00 0.00
1.3.3 For water tanker slab & beam
Dia 8 mm deformed bar Kg 8.00 0.00
Dia 10 mm deformed bar Kg 100.00 0.00
Dia 16 mm deformed bar Kg 28.00 0.00
1.3.4 For water tanker slab & beam
Dia 6 mm deformed bar Kg 8.00 0.00
Dia 12 mm deformed bar Kg 31.00 0.00
Total carried to summary USD 0.00
Walls shall be constructed from class 'B' hollow concrete block (H.C.B.). The blocks shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the blocks shall be in such a way that good key for plasterer is obtained on both side.
2.1 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. m2 349.00 0.00
2.2 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B), the hollow part shall be fully grouted with cement sand mortar and jointed in cement sand mortar mix (1:3) one side left for appropriate finishing and the other side left for to fix sika joint or fiber board.Price shall include cement sand mortar fill inside hollow part of the wall. For X-ray room back wall m2 62.00 0.00
2.3 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) with vertical & horizontal stiffeners bedded and jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. The stiffening methods and application shall be as per the detail structural dwg. Price shall include stiffening concrete and reinforcement.Price shall also include the recessed decorative wall part showing on the right & left side of the building.-for parapet wall m2 48.00 0.00
2.4 Supply and lay 10 cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. m2 6.00 0.00
2.5 Supply, delivery, preparation, and installation of combined brick layers of ( 20 cm + 10 cm),total 30cm thick red burnet brick wall cladding for internal X-ray room walls surface shown on the Ar. Drawing.The construction must comply with radiation protection requirements and shall be proper sealed with sika or fiber board to prevent radiation leakage. The material physical property shall meet the minimal standard to suit the intended purpose. The installation work shall be as per the architectural detail plan and shall be install from bottom up. The contractor shall submit the material sample. Shop drawing showing fixing details. Installation method and mockup sample shall be constructed for the Architect approval.price shall include 10mm thick SIKA or fiber board joint filler (wall substrate) & bonding bar with HCB wall. m2 62.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 235.00 0.00
3.2 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet ridge hip at the roof slope direction changes. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of ridge cap: 80 cm. m.l. 9.00 0.00
3.3 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 50.00 0.00
3.4 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel vally gutter, supported by the side truss members the work shall include all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 450 mm ml 4.50 0.00
3.5 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet copping at the top roof ridge exposed HCB wall. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of copping: 410 mm. m.l. 24.00 0.00
3.6 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 44.00 0.00
3.7 Supply and fix diam 110mm PVC down pipe. Price shall include 900 elbow connection, PVC liner with all the necessary fixing accessories. ml 52.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors and windows all as per the drawing. All doors should have vertical metal grill 25x25x2mm c/c 15cm for burglar proofing and with 0.5mm thick steel louver at top welded to frames and covered with approved mosquito net. All windows should have RHS 10x10x2mm welded to frames and with steel mesh for burglar proofing. All roof vent should have steel mesh welded on the frame. Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint. (glazing measured separately).
TW-1 size 150 x 85 cm no 2.00 0.00
D-1 size 180 x 255 cm-doble leaf door no 1.00 0.00
D-2 size 90 x 255 cm-single leaf door no 6.00 0.00
D-3 size 85 x 255 cm-single leaf door no 2.00 0.00
4,2 Supply, deliver, install, test, and commission factory made steel-framed, lead-lined radiation shielding X-ray door with vision panel, complete with all accessories and certification. The material shall be Steel door frame and solid core door leaf, factory fabricated, Lead lining to door leaf and frame equivalent to 2.0 mm Pb minimum, Vision panel comprising lead glass with equivalent 2.0 mm Pb shielding, Complete set of heavy-duty ironmongery including hinges, lockset, handles, and door closer, Perimeter sealing with radiation-proof gaskets to prevent leakage, Proper installation including lead overlap at joints and shielding continuity and the work shall include Testing, commissioning, and submission of radiation protection compliance certificate. All are as per the detail door and window schedule and engineers approval.
D-1' size 180 x 255 cm-doble leaf door no 1.00 0.00
D-2' size 90 x 255 cm-single leaf door no 1.00 0.00
4,3 Supply, fabrication, and installation of rectangular roof ventilation unit, overall size 80 cm × 40 cm, consisting of fabricated from 38 mm LTZ-profile, 0.16 cm thick frame. Joints to be welded with 4 mm continuous fillet welds, ground smooth and free of sharp edges. Infill woven wire mesh aperture 1.4 mm × 1.4 mm, wire diameter 0.45 mm, securely fixed to frame by recessed groove or retaining clips. Entire vent unit to be cleaned, degreased, and painted with on coat of anti-rust followed by two coats of metal paint. The color shall be approved by the Engineer and the work shall complete as per drawing. no 8.00 0.00
4.4 Supply, fabricate and fix metal guard rail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 120 × 120 × 6 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 1000 mm above finished floor level; two horizontal balustrade rails CHS Ø20 × 2.5 mm welded to vertical RHS posts; top handrail CHS Ø50 × 2.5 mm welded continuously; infill: vertically spaced CHS Ø20 × 2.5 mm at c/c 100 mm between the two horizontal rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 21.00 0.00
4.5 Supply, fabricate and fix metal ramp handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 15.00 0.00
4.6 Supply, fabricate, deliver, install, and paint steel cattle fence (balustrade type) comprising CHS vertical posts, horizontal rails, and base plates, fixed to concrete floor, complete in all respects. The work shall be Steel fence consisting of Ø100 × 5 mm CHS vertical posts (900 mm height) fixed to concrete using 170 × 170 × 6 mm base plates, spaced at maximum 1000 mm centers, with 4 No. horizontal Ø80 × 2.5 mm CHS rails welded to posts, including all welding, anchoring bolts, alignment, and accessories, finished with anti-rust primer and final metal paint (minimum two coats each), complete as per drawings and Engineer’s approval. ml 14.00 0.00
4.7 Supply and fix elevated water tanker seat metal guard rail all according to size and shape specified on the drawing . Price shall include connection plates, bolt and one coat of primer & two coats of synthetic enamel paint. ml 8.00 0.00
4.8 Ditto as above item and supply, fabricate, deliver,instal and paint steel structure ladder as shown the At. detail drawing. ml 8.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect steel structures using RHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel Structure Column
Steel structure columns are vertical primary load-bearing members, transferring axial loads (and occasionally bending) from trusses to foundations. Since columns are in direct contact with water during cleaning, apply bituminous damp-proof paint at the column base up to a height of 300 mm (30 cm) to prevent corrosion and moisture penetration. price shall damproof paint and stiffening plates as shown in the drawing. for measurment net RHS post will be considered execluding stiffening plates.
A.1 Steel structure column RHS sections of 100 × 100 × 4mm for veranda post. kg 218.00 0.00
B. Steel Structure Column Beam
The beam shall be welded column to column just below the top plate level where truss and column connected. At the end of the beam where there is no steel column. it connected with the building it will be fixed with plate at the concrete column/tie beam
B.1 RHS 80 x 60 x 4mm beam for veranda kg 245.00 0.00
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards. Price shall include gusset plat, connection plate when truss members connect and bolts other than anchor/J-bolt bolts.
C.1 RHS 80 x 80 x 4mm upper & lower truss member for T1 & T2 Kg 1,701.00 0.00
C.2 RHS 60 x 60 x 3mm upper & lower truss member for T1', T3, T4 & T5 Kg 424.00 0.00
C.3 RHS 60 x 60 x 4mm diagonal & vertical truss member for T1 & T2 Kg 685.00 0.00
C.4 RHS 50 x 50 x 4mm diagonal & vertical truss member for T3, T4 & T5 Kg 151.00 0.00
D. RHS Purlins 0.00
D.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 100 x 100 x 3mm L= 60mm angle iron. Price include angle iron. Kg 2,145.00 0.00
E. RHS Solar PV Support System 0.00
Supply, fabricate, deliver and install solar panel steel support structure complete with all necessary connection components. The work shall include provision of gusset plates, bolts, nuts, washers, and all fixing accessories required for proper assembly and stability of the structure.The rate shall include surface preparation and application of approved anti-corrosion primer and finishing paint. It shall also include proper sealing and waterproofing treatment where steel members penetrate the roof covering, ensuring no water leakage. All works shall be executed in accordance with approved shop drawings, specifications, and engineer’s instructions.
E.1 RHS 80 x 80 x 4mm steell structure frame member Kg 2,267.00 0.00
E.2 RHS 60 x 60 x 4mm steell structure frame member Kg 409.00 0.00
E.3 RHS 40 x 40 x 4mm purlin Kg 637.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate for verenda post-size 250 x 250 x 6mm with 4 dia 22 slotted holes. The plated is welded to the RHS post (fillet weld of 3mm throat thickness) and connected to the other plate fixed on concrete column. No 12.00 0.00
A.2 Base plate size 250 x 200 x 6mm with 4 dia 18 slotted holes for truss & ring beam. The plate is welded to the truss (fillet weld of 3mm throat thickness) and connected to ring beam. No 90.00 0.00
A.3 Top plate size 150 x 150 x 8mm for veranda post and RHS beam connection with bolt & nut. No 12.00 0.00
B Bolt with nut
B.1 Base plate/Anchor bolt dia. 16 Length 250mm for truss beam connection and to be weld to ring beam steel reinforcement No 180.00 0.00
B.2 Base plate/Anchor bolt dia. 20 Length 450mm for veranda post No 24.00 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of gypsum finish to internal HCB wall surfaces. m2 535.00 0.00
6.2 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of gypsum finish to internal exposed beam and column surfaces. m2 69.00 0.00
6.3 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive rendering finish to externall HCB wall surfaces. m2 205.00 0.00
6.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final rendering finish to external exposed beam and column surfaces. m2 112.00 0.00
6.5 Prepare the surface and apply final a 3 mm to 5 mm thick final skim coat using a 1:3 cement-to-fine-sand mortar mix. Fine sand must be sieved through a 1.18 mm mesh. The surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks to internal wall, beam & column surfaces. m2 604.00 0.00
6.6 Prepare the surface and apply final apply 15mm thick cement and sand rendering (1:3 mix) for external wall surface. Price includes surface preparation, hacking of concrete surfaces, wire mesh for joints, curing for 7 days. The rendering pattern shall be as per the Architect approval. m2 317.00 0.00
6.7 Prepare the surface, supply and construct 2 cm thick x 25 cm wide polished marble threshold for doors bedded on cement sand mortar 1:3. Price include 30mm thick cement sand mortar backing and white cement grouting. All are as per the detail Ar. Dwg. ml 10.00 0.00
6.8 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 59.00 0.00
6.9 Prepare the surface, supply and fix nominal thickness of 0.85 cm approved standard 60 x 60 cm non-slippery ceramic floor tiles bedded in an average 4.15 cm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 12.00 0.00
6.10 Prepare the surface and apply epoxy resin coating flooring as shown in the drawing- the epoxy flooring shall be suitable type for veternary clinic:- Epoxy floor, shall be applied on the concrete floor or 4.6 cm thick cement sand screed flooring using OPC cement and Rheomix 141 strengthening additive in order to achieve the required bedding strength for animal hoof. The application of the screed shall be leveled and finished with a fine texture screening while the concrete is fresh and it is preferable to hold the proper application of epoxy floor finish with out any additional leveling. screed to the base floor shall be done with proper slope as instructed by the engineer and shall be done as per the advice and follow up of the epoxy supplier in order to assure the bonding between the concrete slab and screed. The contractor should use bonding chemical agent primer that shall be approved by the Engineer. Price shall include screed, Rheomix 141 strengthening additive and epoxy floor finish. m² 38.00 0.00 4800 0 0 4800 #REF! #REF! #REF! #REF! #REF! #REF!
6.11 Prepare the surface and construct belt & brace flooring as shown the detail Ar. Detail drawing. The work shall be 1 x 2 cm slip resistance diamond grooved finish with non metalic dry shake hardner. All are as per the detail drawing, manufacturere instruction and Engineer approval. m² 93.00 0.00
6.12 10cm high 1cm thick chamfered ceramic skirting of matching color to floor tiles. ml 106.00 0.00
6.13 Supply and fix 30 x 60 x 0.85 cm ceramic wall cladding, of matching color to floor, stuck to wall with cement sand mortar 1:3 backing and grouting with white cement wash. Price shall include rod anchors to backing. Size, color and pattern according to architect's drawings. m2 106.00 0.00
6.14 Supply and fix granite stair tread bedded on cement mortar 1:3 price include mortar bed, nosing and chamfering. Color and pattern shall be approved by the Architect.
a) For entrance step-tread
- Tread size: (33 x 3 cm) ml 8.00 0.00
6.15 Ditto as above but riser.
a) For entrance step-rise
- riser size: (13.4 x 2 cm) ml 8.00 0.00
6.16 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick marble window sill. Price shall include cement sand mortar bed and cement grouting. ml 12.00 0.00
6.17 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick marble short wall copping. Price shall include cement sand mortar bed and cement grouting. ml 12.00 0.00
6.18 Supply and fix chamfered, bullnose and water dripped 25 x 3cm thick marble edge trim for veranda edge. Price shall include cement sand mortar bed and cement grouting. ml 21.00 0.00
6.19 Supply and fix approved quality 0.8cm thick chip wood ceiling as per the detail drawing and engineers approval. The batten fixing method with steel truss shall be L-shaped or U-shaped steel brackets welded/bolted to the steel truss members. Battens are then nailed or screwed to the brackets. Price shall include 4 x 5 cm suspensions wooden battens with c/c spacing of 600mm both ways, middle and corner list, nails and all the necessary fixing accessories. m2 105.00 0.00
6.20 10 cm thick Concrete pavement around the building bedded on 10 cm thick red ash or fine aggregate and 20cm thick compacted granular materials. The work shall be mixing, placing, compacting, curing, and finishing of concrete with trowel finish while fresh. Price shall include red ash bed, selected fill and trowel finishing work. m2 90.00 0.00
Total Carried to summary USD 0.00
7.1 Supply and fix 0.5cm thick clear glass. Price shall include all the necessary fixing accessories. m2 15.00 0.00
7.2 Supply and fix 0.5cm thick figured glass. Price shall include all the necessary fixing accessories. m2 6.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
8.1 Apply three coats of plastic emulsion paint to internally gypsum plastered wall surfaces. m2 604.00 0.00
8.3 Ditto as item 8.1, but to chip wood ceiling. m2 105.00 0.00
8.3 Apply final acrylic emulsion paint to external rendered wall surface, exposed R.C columns and beams. m2 317.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
PORT SUDAN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.2- Veternary Building-Electrical Installation
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
9 ELECTRICAL WORKS
9.1 uPVC Pipes and Ducts
9.1.1 50mm diameter uPVC m 10.00 0.00
9.2 Earth Network (Grounding System)
9.2.1 Grounding pit 500x500x500mm with top cover inscribed "Grounding pit" as per the detail drawing No 1.00 0.00
9.2.2 Under ground termination network with bare copper cnductor of 1x70sq.mm ml 100.05 0.00
9.2.3 Insulated ground connecting copper cable of 1x70sq.mm ml 30.00 0.00
9.2.4 Earthing electrode diameter 20mm and length 3000mm
Note:If the earth resistence is more than 10 ohms
add additional electrode spaced at length of
the electrode (spaced at a minimum of 5m appart) No 5.00 0.00
9.3 DISTRIBUTION BOARDS
9.3.1 Factory assembled and tested surface-mounted main distribution Board, MDB in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting:
1pc main RCBO of 50A, 3ph , Icu=16KA, 30mA.
1pcs MCB of 32A, 3ph , Icu=10KA
2pcs MCB of 20A, 1ph , Icu=10KA
7pcs MCB of 16A, 1ph , Icu=10KA, coupled with RCD of 30mA. 0.00
8pcs MCB of 16A, 1ph , Icu=10KA
4pcs MCB of 10A, 1ph , Icu=10KA
2pcs MCB of 16A, 1ph (spare) Icu=10KA
1Pc of surge arrestor of 40KA
3 pcs current meters of 50/5A with 6A fuse
1 pc Volt meter of 500V with selector switch and 6A fuse
1 pc frequency meter
with 25% reserve space and busbar of 63A/3ph. No 1.00 0.00
9.4. Feeder Cables and PVC pipes
PVC Sheathed PVC Insulated power cable type NYY 0.6/1KV or equivalent to be drawn inside riser shaft or PVC conduit (measured elsewhere, tentative) and of:-
Cable sizes include: 0.00
9.4.1 5x10 mm2 From utility connection to MDB (Provesional Quantity) m 20.00 0.00
9.4.2 5x10 mm2 From Inverter to MDB m 5.00 0.00
9.5. Light & Switch Points 0.00
9.5.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 46.00 0.00
9.6. Light Fittings and Lamps 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved.
9.6.L1 LED Panel Light: 600x600mm, 22.5W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 6.00 0.00
9.6.L2 LED Panel Light: 300x1200mm, 27W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 8.00 0.00
9.6.L2E LED Panel Light: 300x1200mm, 27W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free, & ~1000 lumens (emergency), 4000K, 90 minute operation, No 3.00 0.00
9.6.L3 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 11.00 0.00
9.6.L4 LED Batten Light:L600mm, CRI > 80, ceiling-mounted, polycarbonate, IP44, flicker-free. No 2.00 0.00
9.6.L5 LED Slim Downlight: 10W, 1100 lumens, 4000K, CRI > 80, polycarbonate, IP44, 220VAC, driver included, No 8.00 0.00
9.6.L6 Mini LED Wall Pack for Toilet Mirror, 10W, 1000 lumens,4000K, CRI > 80, wall-mounted, polycarbonate, IP65 No 3.00 0.00
9.6.(E) Non-maintained LED emergency light (only activates during power failure). Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). Warranty: 3 years (components), 5 years (battery). No 4.00 0.00
9.6(ODL) Over door light bulk head to indicate occupancy of the xray room No 1.00 0.00
9.6. Socket Points 0.00
9.6. 10-16A/1P flush mounted/recessed socket outlets point fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 20.00 0.00
9.9.2 Dito but for Double Outlet No 10.00 0.00
9.7 Power outlet points.
9.7.1. 16A/1P power outlets point for exaust fan and booster pump fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 8.00 0.00
9.7.2 20A/1P power outlets point for split AC fed through PVC insulated conductors of 3x4mm² inside PVC conduits of 19mm inner diameter, including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type-approved. No 2.00 0.00
9.7.3. 32A/3P power outlets point for X-Ray Machine fed through PVC insulated conductors of 5x6 mm² inside PVC conduits of 32mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 1.00 0.00
9.7. Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard.
9.7. Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete.
9.7.1 Single Pole 1-Way Switch No 6.00 0.00
9.7.2 Double pole Switch No 6.00 0.00
9.7.3 Two Way Switch No 6.00 0.00
9.7.4 Two Way Switch Weather proof for outdoor installation No 2.00 0.00
9.7.4 Intermidiate Switch Weather proof for outdoor installation No 1.00 0.00
9.8. Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00
9.8.1 16A ,1ph ,220V 2p+e socket out let No 20.00 0.00
9.8.2 Dito but Double (Twin) Outlet No 10.00 0.00
9.9 Lightning Arrester System
(Eritech or Equivalent)
Shall include all metalic structures in the network with appropriate welding (ventpipes,ducts ,GIS roof & structures, solar PV panels, e.t.c)
9.9.1 Early Streamer Emmision(ESE) Protector SI 25 with mounting mast of H=3.0m and all necessary connecting acessories. No 1.00 0.00
9.9.2 25x3mm copper tape with all necessary roof connecting accessories m 90.00 0.00
9.9.3 25 x 3mm insulated copper tape with vertical supportings every 1m to the wall & all the necessary accessories coordinate the routing of down conductors with the building external skin and architectural features. ml 40.00 0.00
9.9.4 Lightening Event counter to be installed on the down conductor to count number of lightening strikes. No 2.00 0.00
9.9.5 Test point (junction box) with all necessary connection acessories to connect the down conduction with the earthing bare copper wire. at least 1.5m above floor finish. No 2.00 0.00
9.9.6 Prefabricated Crowsfeet 25x3mm tinned coper tape. In complienc with IEC-EN 62561-2, with L1=1000mm and L2= 3000mm No 2.00 0.00
9.9.7 50 x 50 x 50 cm test pit with top cover inscribed "Test pit" as per the detail drawing No 5.00 0.00
9.9.8 1 x 70 sq.mm bare copper wire. ml 10.00 0.00
9.9.9 Diameter 20mm & 3000mm long copper rod. No 2.00 0.00
9.10 DATA\ Telecome System
Tel/Data according to manufacturer’s and utility supplier’s requirements, supplied, installed, connected color coded including tags and tested, complete, all as specified and / or as shown on the drawings
Structured Cabling
Horizontal CAT6A Cabling
9.10.2 Tel/Data and Data/Data points fed through 2x(twisted pair category 6A UTP cable) inside FRLS PVC conduits of 20mm diameter and thickness not less than 1.5mm with conduits accessories (coupling, junction boxes) for tele/Data outlet socket. No 11.00 0.00
9.10.3 Cat 6A 24 port Patch Panel RJ 45 contact No 2.00 0.00
9.10.4 Cat 6A RJ 45 Patch Cord 0.5m, from switch to pantch panels No 48.00 0.00
9.10.5 Cat 6A RJ 45 Patch Cord 3m, from outlets to workstation computers. No 11.00 0.00
Equipment Racking
9.10.6 Wall Mount metallic rack of 15U pivoting cabinet swing 19" steel enclosure with transparent and lockable door, Built-in PDUs (8-10 Outlets, Grounded) and cooling fans. No 1.00 0.00
9.10.7 1U Horizontal Cable Management Bars, 5 Vertical Plastic Hoops with Cover No 3.00 0.00
Information Outlets: Data &Voice
Extra Over Data Socket Outlets with Detachable Frames & Corresponding Box
9.10.8 2 x RJ45 8 Contact CAT6a Socket Outlets No 11.00 0.00
Active components Type CISCO or approved equivalent.
9.10.10 48-port Gigabit Data +2x10G uplink Switch . No 1.00 0.00
9.10.15 Hybrid PBX with 24Analog, with 4 trunk, Extension including Operator Phone No 1.00 0.00
9.10.16 Cat 6A RJ 11 Patch Cord 1m No 24.00 0.00
9.11 FIRE ALARM SYSTEM
9.11.1 Convensional Fire alarm Control Panel, 2 zones Complete with power supply & battery backup. No 1.00 0.00
9.11.2 smoke detector; with Flash Scan and Detector Base, Complete No 10.00 0.00
9.11.4 Fire alarm sounder strobe (RED) No 2.00 0.00
9.11.5 Surface mounted manual break glass push button including back box No 2.00 0.00
9.11.6 Flush Mounted Fire Alarm Points fed in 2 x 1.5sq. mm Fire Alarm cable (SLC-detectors) inside FRLS PVC conduits of 16mm diameter and thickness not less than 1.5mm with conduits accessories (coupling, junction boxes) No 14.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
PORT SUDAN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.3- Veternary Building-Sanitary Installation
CLINIC BLOCK SANITARY WORKS
1.1 SANITARY EQUIPMENET ( FIXTURES ) USD 0.00
1.2 Water Supply Pipes and Valves USD 0.00
1.3 Waste Pipes and Accessories USD 0.00
1.4 HVAC System USD 0.00
1.5 Fire Fighting System USD 0.00
Total Veternary Clinic Building-Sanitary Installation USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 SANITARY EQUIPMENET ( FIXTURES )
All fixtures which are specified below is subject to the owner's / consultant's approval, based on samples, catalogues and brochures presented by the contractor. Unit price shall include all the necessary fixing brackets or hooks and all assistance civil works such as chiseling of walls, floors, beams and etc.
1.1.1 HAND WASH BASIN (ORDINARY)
Supply and fix R.A.K. or Equivalent, hand wash basins made of white glazed vitreious china with REMER/JAQUAR or Equivalent chrome plated cold water tap, pedastal stand ,complete with stop & arrest valves on water inlet pipe. mixing battery plug, chrome plated chain holder, P-smell trap with connection pipe, fittings, all other necessary etc.complete in all respects. Flexible hose to be REMER or Equivalent and should be capable of resisting pressure of 4 bar. P-smell trap should be brass chrome plated with 50mm height of water seal and trap. № 1.00 0.00
a) Size :- length X width (1000mm x 435mm)
1.1.2 Ditto No 1.1.1 but for animal health clinic medical laboratory and surgical purpose each with two bowl. № 2.00 0.00
1.1.3 Ditto No 1.1.1 but for cleaner room № 1.00 0.00
WATER CLOSET (ORDINARY)
1.1.4 Supply and fix wash-down action toilet squatting pans made of white vitreous china, complete with high-level flush cistern, vertical flush pipe connecting the cistern to the squatting pan, and all necessary accessories. The price shall include stop and arrest valves before water inlet; cistern of vitreous china with a capacity of 7 to 9 liters and maximum filling time of 2 minutes, complete with heavy-duty float valve suitable for water pressure up to 4 bar; chrome-plated steel flush valve; heavy-duty flexible pipes rated for a working pressure of 4 bar; and vertical flush pipe of durable corrosion-resistant material (e.g., galvanized steel, stainless steel, or UPVC) connecting the cistern outlet to the pan inlet, complete with necessary bends, brackets, and wall fixings. Where specified, a hygienic flush/bidet connection shall be provided, comprising a flexible hose, handheld spray nozzle, wall bracket, and appropriate isolating valve. № 2.00 0.00
SANITARY WARES FOR PERSONS WITH DISABILITY (PWD)
1.1.5 Supply and install complete set of sanitary wares for physically challenged toilet room fixtures and accessories including: *Vitreous china wc seat with brass or stainless steel hingedheavy duty plastic cover*Vitreous china hand wash basin with lever action faucet with mixer, brass or chrome smell traps and accessories * 6 liters capacity vitreous china cistern with long lever action flushing arm * 5 pieces of stainless steel grab rails (600x35mm) with slip resistant grip and concealed fixings* Blue Folding rails 850mm,760x305mm flush bends,cloth hooks * Stainless steel lever action hinged drop down rail * Color contrasted padded backrest * Automatic hand dryer * Soap Dispenser * Paper Towel Dispenser * Toilet Tissue Dispenser * Alarm Rest Button * Stainless steel Mirror 1000*400mm & all the necessary material to make the toilet functional. The sanitary ware set shall satisfy BS 8300-2 and BS EN 12182. № 1.00 0.00
1.1.6 WET ROOM ACCESSORIES
1.1.6.1 Supply and fix soap holder in white vitreous china of size 150 x 150 mm. Complete with the necessary fixing and other accessories. № 3.00 0.00
1.1.6.2 Supply and fix toilet paper holder from chrome plated brass wall flanged roll with chrome plated fastening screws and other accessories. № 2.00 0.00
1.1.6.3 Supply and fix crystal glass mirrors for toilets hand wash basins for changing rooms and private rooms with copper back protection, including chrome plated brass mirror clips with chrome plated screws and all the necessaary accessories. a) size 500 X 400 mm № 3.00 0.00
1.1.6.4 Supply, fix, test and commission floor drains made of polished steel, complete with P-smell trap /minimum seal depth 75mm/ and all other necessary fittings and accessories. № 4.00 0.00
Total carried to summary USD 0.00
1.2 Water Supply Pipes and Valves
Domestic water pipes shall be in PPR- PN 4 & be fixed to walls, beams or etc… with metal/ compatible straps. Unit price shall include all assistance civil works and necessary fittings such T, bends, Y, reducers Unions and other necessary valves shall be fixed properly as per the manufacturer's instruction and according to where shown on the drawing. Hot water supply shall be properly insulated and external PPR pipe has to be coated All water pipes shall be tested two times the working pressure or 100 meters head, which ever is greater at the expense of the contractor.
1.2.1 Supply and install PPR PN-4 pipes to internal domestic water distribution system pipes as where shown on the drawing. And external pipes shall be coated Complete with all the necessary fittings and accessories. The pipe shall be coated when applied on exposed surfaces
1.2.2 Supply and fix chrome service valves of approved standard before hand wash basins, water closets and other fixtures. Complete with unions, elastic water proofing, hand wheels of normal quality and with all other necessary accessories.
1.2.3 Ditto to item number 1.2.2 approved quality bronze gate valves on internal branch water pipes and pipe inlet to building of the following size and as where shown on the drawing
1.2.4 Supply, Installation, Testing, and Commissioning of Wall/Window Mounted Exhaust Fan: Fan Unit: The exhaust fan shall be a wall or window mounted type, specifically designed for bathroom/ toilet ventilation. Performance: Airflow Capacity: Minimum free air delivery of 200 cubic meters per hour (m³/hr) at 25 Pa static pressure. Sound Level: The maximum sound power level (Lw) shall not exceed 35 dB(A) when measured in accordance with relevant standards. Components & Accessories: The unit shall be complete with all necessary accessories for effective operation, including but not limited to: Multi-speed controller. Integral back-draft shutter. External rain guard/weather louvre. Grille or front cover. All required fixings, gaskets, and seals. Scope of Work: The unit rate shall be inclusive of, but not limited to, the following activities: Supply of the exhaust fan and all specified accessories. Necessary civil works to create or make good the opening, including sealing and making the installation weatherproof. Electrical wiring from the nearest power source, including a dedicated isolation switch, as per electrical codes. Final installation, testing, and commissioning of the system to ensure optimal performance. № 2.00 0.00
Total carried to summary USD 0.00
1.3 Waste & vent Pipes and Accessories
All domestic waste water pipe lines shall be uPVC (PN10) pipes and shall be provided with a minimum slope of 2% towards the outlet. All uPVC pipes and necessary fittings shall be standard quality and be free from damage during storage, construction and etc. Unit price shall include all the necessary assistance civil works, such as excavation cartaway, fixing or hanging to walls, beams or slabs.etc., necessary fittings such as bends, Y, T, etc.
1.3.1 Supply and lay internal uPVC waste according to where shown on the drawings. Complete with all the necessary fittings.
Dia. 50 mm ml 4.00 0.00
1.3.2 Ditto No 1.3.1 for vent pipes with appropriate end cap
1.3.3 FCO(FLOOR CLEAN OUT)
Supply and fix approved quality screw type under slab Clean Out on waste water as where shown on the drawing. Price shall include all the necessary
1.3.4 Animal waste open dith with galvanized steel grate for cattles out door treatment area ml 4.00 0.00
DITCH-: SIZE[mmXmm] = 300 X 300
1.3.5 Dito 1.3.4 but for animal health clinic cattles recovery room treatment area ml 4.00 0.00
DITCH-: SIZE[mmXmm] = 300 X 300
1.3.6 Dito 1.3.4 but for animal health clinic treatment room & X ray rooms.
DITCH-: SIZE[mmXmm] = 300 X 300 ml 8.00 0.00
Total carried to summary USD 0.00
1.40 HVAC System
Supply, installation, testing, and commissioning of HVAC and mechanical ventilation systems for four (4) distinct room types considering high ambient operation temperature of 52 ºC.The items shall be Anti-corrosion treatment for coastal sites, refrigerant pre-charged for up to 15m piping length, Service valves with Schrader ports. The scope of the work include power cabling work from power point to HVAC equipment.
1.4.1 Supply, install, test and commission a complete high ambient split-type air conditioning unit of 1.5 TR (5.3 kW cooling capacity, equivalent to 18,000 BTU/h). The unit shall be inverter type, utilizing R32 or R410A refrigerant (R22 is strictly prohibited), and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 1.3 kW. The system is designed for cooling only and shall be factory-rated for continuous operation in high ambient temperatures up to 52°C. The system shall consist of one (1) wall-mounted indoor evaporator unit and one (1) outdoor condensing unit, complete with all interconnecting refrigerant piping, control wiring, condensate drain line, remote control handset, and all necessary accessories for a complete and functional installation. Indoor Unit (Evaporator): The indoor unit shall be constructed of UV-stabilized ABS plastic with a white finish. It shall include automatic horizontal and vertical swing louvers, a washable antimicrobial pre-filter, and a cross-flow fan designed for silent operation.
Outdoor Unit (Condenser): The outdoor unit shall be an inverter-driven condensing unit with digital inverter (variable speed) compressor, specifically rated for high ambient operation. The unit shall include corrosion-resistant condenser coil and fan motor. Refrigerant Piping: Interconnecting refrigerant piping shall be provided for a distance of not less than 15 meters (49 feet) between the indoor and outdoor units. The piping shall consist of seamless copper tubing, with liquid line of 6.35 mm (1/4 inch) OD and suction line of 12.7 mm (1/2 inch) OD. The suction line shall be insulated with 13 mm (0.5 inch) thick closed-cell elastomeric foam. Control and Operation: The system shall include a wireless infrared remote control handset enabling full functionality. Features shall include LED display with temperature readout, sleep mode, turbo cooling mode, on/off timer (1-24 hours), auto restart after power failure, and self-diagnostic fault code display. Electrical Characteristics: The unit shall have rated load amps (RLA) of approximately 6.0 A, minimum circuit ampacity (MCA) of 8.0 A, and maximum overcurrent protection (MOP) of 15 A. All electrical components shall be rated for 230V / 50Hz supply. Condensate Drain: The unit shall include a condensate drain line of 25 mm (1 inch) nominal diameter PVC pipe, properly trapped and sloped at minimum 1:100 gradient to designated drainage point. Compliance: The equipment shall satisfy conformity with European health and safety standards (IEC 60335-2-40) or equivalent international certification acceptable in Sudan. The Contractor shall submit manufacturer cut sheets and conformity certificates for engineer's approval prior to procurement. Acceptable Brands: Gree, Midea, LG, Carrier, Daikin, or approved equivalent. № 1.00 0.00
1.4.2 Supply, install, test and commission a complete wall-mounted, high ambient exhaust fan for the X-Ray room, designed to provide mechanical extraction of air while maintaining negative pressure and preventing radiation leakage. The fan shall be mounted directly on the exterior wall face over a specially constructed shielded labyrinth penetration through the brick wall. No external ductwork shall be required. The fan shall be centrifugal or axial type,The fan shall deliver a minimum airflow of 150 m³/h (approximately 90 CFM) at static pressure of 100 Pa (10 mmH₂O or 0.4 inches w.g.) rated for continuous operation in high ambient temperatures, and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 0.08 kW (80 Watts) . The system is designed for exhaust-only ventilation (no supply fan) and shall be installed in conjunction with a passive labyrinth intake for fresh air. The system shall consist of one (1) wall-mounted exhaust fan (maximum power: 0.08 kW), one (1) shielded labyrinth penetration constructed through the brick wall, one (1) interior exhaust grille (high-level mounted), one (1) exterior weatherproof louver, one (1) backdraft damper, and all necessary accessories for a complete and functional installation. No ductwork (rigid or flexible) is required between the fan and the room. The Contractor shall construct a shielded labyrinth penetration of "S" or "Z" configuration (offset path) through the 450 mm thick wall. No straight line of sight shall exist from the interior of the X-Ray room to the exterior fan housing or to the outside environment. № 1.00 0.00
1.4.3 Ditto No 1.4.1 but for laboratory room and with cooling capacity of 2.0 TR (7.0 kW cooling capacity, equivalent to 24,000 BTU/h) and maximum power input of 1.80 kW (1,800 Watts) . № 1.00 0.00
1.4.4 Supply, install, test and commission a wall-mounted fresh air supply fan for the Laboratory Room, designed to provide forced filtered(with MERV 8 filter (replaceable type) to filter incoming outdoor air) outdoor air to meet the ventilation requirement. The fan shall be mounted directly on an exterior wall or window, requiring no ductwork. The fan shall be rated for continuous operation in high ambient temperatures up to 52°C, and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 0.1 kW (100 Watts) . Performance Characteristics: The fan shall deliver a minimum airflow of 200 m³/h (approximately 120 CFM) at static pressure of 50 Pa (5 mmH₂O or 0.2 inches w.g.) – lower static pressure is acceptable because no ductwork is attached. Construction: The fan shall be of wall-mounted type, suitable for through-wall or through-window installation. The fan casing shall be constructed of UV-stabilized ABS or galvanized steel with corrosion-resistant coating. The motor shall be sealed type, IP44 minimum (or IP54 for exterior exposure). The fan shall include: Integral backdraft damper (gravity-operated) to prevent reverse airflow when fan is off, Integral insect screen on exterior side,Exterior weatherproof louver (may be integral or separate),Interior grille (may be integral or separate) with manual damper for airflow adjustment, Mounting: The fan shall be mounted on a wall or window frame on one side of the room (e.g., the 4.8 m wall). A circular or rectangular hole shall be cut through the wall or window frame to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. The fan shall be installed level and plumb. № 1.00 0.00
1.4.5 Ditto No 1.4.4 but for exhaust air system designed to maintain negative pressure and remove airborne contaminants from laboratory room and shall deliver a minimum airflow of 500 m³/h (approximately 300 CFM) at static pressure of 50 Pa (5 mmH₂O or 0.2 inches w.g.) – lower static pressure is acceptable because no ductwork is attached. The fan shall consume maximum 0.1 kW (100 W) . Low-Level Mounting: For effective removal of heavier-than-air contaminants (e.g., chemical vapors, dust), the exhaust fan should be mounted low on the wall, approximately 200 mm to 500 mm above finished floor level. The Contractor shall confirm the mounting height with the Engineer prior to installation. Mounting: The fan shall be mounted on the wall opposite the supply fan (e.g., on the opposite 4.8 m wall). A circular or rectangular hole shall be cut through the wall to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. The fan shall be installed level and plumb. № 1.00 0.00
1.4.6 Ditto No 1.4.4 but for tretment room and shall deliver a minimum airflow of 900 m³/h (approximately 530 CFM) at static pressure of 50 Pa (5 mmH₂O), while consuming maximum 0.37 kW (370 W) . № 1.00 0.00
1.4.7 Ditto No 1.4.5 but for tretment room and shall deliver a minimum airflow of 150 m³/h (approximately 90 CFM) at static pressure of 50 Pa (5 mmH₂O), while consuming maximum 0.08 kW (80 W . The fan shall be mounted on the wall opposite the supply fan to achieve cross-ventilation. The fan may be mounted at mid-height (1.5 m AFF) or high level. A circular or rectangular hole shall be cut through the wall to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. № 1.00 0.00
1.4.8 Ditto No 1.4.5 but for a complete exhaust-only ventilation system for the Animal Clinic Isolation Room, designed to deliver a minimum airflow of 1,000 m³/h (approximately 590 CFM) at static pressure of 150 Pa (15 mmH₂O), while consuming maximum 0.2 kW (200 W) maintain negative pressure for containment of airborne pathogens.The fan shall be mounted directly on an exterior wall, requiring no ductwork (or minimal ductwork for distribution). The fan shall be rated for continuous 24/7 operation, and shall operate on a single-phase 230V / 50Hz power supply. № 1.00 0.00
1.4.9 Ditto No 1.4.1 but for electric/battery room and with cooling capacity of 0.85 TR (2.5 kW cooling capacity, equivalent to 8530.36 BTU/h) and maximum power input of 0.60 kW (600 Watts) . № 1.00 0.00
1.4.10 Ditto No 1.4.5 but for a complete exhaust-only ventilation system for the toilet cubicles, designed to deliver a maximum airflow of 300 m³/h (approximately 176.57 CFM) at static pressure of 60 Pa (0.45 mmH₂O), while consuming maximum 0.06 kW (60 W) maintain negative pressure for containment of airborne pathogens.The fan shall be mounted directly on an exterior wall, requiring no ductwork (or minimal ductwork for distribution). The fan shall be rated for continuous 24/7 operation, and shall operate on a single-phase 230V / 50Hz power supply. № 2.00 0.00
1.4.11 Ditto No 1.4.10 but for janitory room. № 1.00 0.00
Total carried to summary USD 0.00
1.50 FIR FIGHTING SYSTEM
4.10 Supply and fix 5kg of ABC type fire extinguisher with metal protection cover as per shown location on the drawing. № 6.00 0.00
4.20 Ditto ( 4.1) but CO2 type for solar electrical control room № 1.00 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
PORT SUDAN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.3 Solar PV Installation
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
Supply, install, test, and commission a roof-mounted solar photovoltaic (PV) system with a total installed capacity of 22.78kWp, complete with battery storage and a three-phase inverter, designed for reliable off-grid operation. The system shall be engineered for a minimum service life of 20 years, and shall include all required components, accessories, protections, and ancillary works necessary to deliver a fully functional and complete installation, consisting of the following:
1 PV Modules Type Longi solar or approved Equivalent
Monocrystalline bifacial module, 670 Wp, efficiency ≈24.8%, Voc ≈54.6 V, Vmpp ≈45.27 V, IEC 61215/61730 certified. 2 rows × 16 modules roof-mounted; Tier-1 quality and high reliability. Type Longi solar or approved Equivalent. No 32.00 0.00
3 Hybrid Inverter Type Huawei or approved equivalent
3-phase hybrid inverter, 25kW output, 2 MPPT (200–1000 V DC), efficiency ≥ 98.4 %. Integrated battery interface & smart monitoring. No 1.00 0.00
4 Battery System, Type Huawei or approved equivalent
Lithium Iron Phosphate (LFP) stack 15 kWh nominal (14.25kWh usable), 600 V DC nominal range (600–980 V) for 3Ph system. Safe chemistry >4000 cycles. stacks 2.00 0.00
5 Battery Control Modules (PCM)
Power Control Module per stack, manages communication and charge/discharge interface to the hybrid inverter. pcs 2.00 0.00
6 DC protection panel
IP65, 1000V DC protection panel (PV Rated) with busbar ≥ array Isc , 63A, earthing terminal, and all associated accessories consisting of:
2pc DC-rated MCB of 25A
2pc DC-rated String isolator of 32A
1pc, PV rated DC SPD, Type II, In ≥ 20KA pcs 1.00 0.00
All components shall be rated for a minimum of 1000 VDC and suitable for photovoltaic applications. pcs 1.00 0.00
7 DC & AC Cabling
Cu XLPE cables rated 1 kV DC/AC; Includes MC4 connectors, lugs, glands, and labels. ≤ 1.5 % V-drop. 0.00
7.1 1x 4mm2 1kv/DC cables, PV string, and from DC protection Panel to Hybrid inverter. ml 60.00
7.2 2x 6mm2 1kv/DC cables, PV string, and from DC protection Panel to Hybrid inverter. ml 10.00 0.00
7.3 2x 10mm2 1kv/DC cables from Hybrid inverter to Battery stacks. ml 10.00 0.00
7.4 5x 10mm2 0.6/1kv AC cables from Hybrid inverter(HIN) to MDB ml 10.00 0.00
8 Monitoring & Communication
Smart Dongle / Gateway (Wi-Fi or Ethernet). Real-time data, alarms, remote monitoring and system analytics. Type Huawei FusionSolar or approved equivalent. set 1.00 0.00
9 Earthing & Lightning Protection
The Solar PV strings shall be bonded to the Early Streamer Emission (ESE) lightning protection roof network using 25 × 3 mm copper tape to ensure effective lightning protection. The PV array structure shall also be bonded to the main earthing network through 70 mm² copper earthing cables, bonding bars, and lightning down conductors. The overall earthing system shall achieve an earth resistance not exceeding 5 Ω. LS 1.00 0.00
10 Installation, Testing & Commissioning
Complete installation of PV array, battery, inverter, wiring, earthing. Includes polarity, insulation, I-V curve, and BMS integration tests, training & handover. LS 1.00 0.00
11 Contingency / Miscellaneous
Spare connectors, cable glands, fasteners, transport, minor site materials. Covers unforeseen adjustments during installation. LS 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
PORT SUDAN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.4-Water Reservior Plat form & Pump Control Switch Room-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A 0.00
B. SUPER-STRUCTURE
1 BLOCK WORK USD 0.00
2 ROOFING USD 0.00
3 METAL WORK USD 0.00
4 STEEL STRUCTURE USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No additional allowance for working space to be considered for measurement. The site clearing area shall be the net built-up area including aprons, open ditch, entrance step and ramp. m2 10.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for the ground floor from the Average Natural Ground Floor Level (A.N.G.F.L.) to a depth not exceeding 150 cm. The volume of excavation shall be measured only over the net built-up area of the building footprint, excluding aprons, open ditches, and ramps. Working allowance: An additional 0.50 m width on each side of the excavation shall be included to allow for proper working space. Reference level (A.N.G.F.L.): The A.N.G.F.L. is defined as the average of the topographic ground levels taken at the building footprint prior to any excavation works, reduced by 20 cm to account for above work item site clearing. m3 3.50 0.00
1.3 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level. Note: measurement shall include 150 cm working space in each side for trench excavation. m3 3.10 0.00
1.4 Back fill under hard core and around the building with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 3.00 0.00
1.5 Back fill around masonry wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 2.00 0.00
1.6 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material. Disposal shall be measured as the net volume arising from the void created by the excavation, less excavated material backfill, filled and wheel spread within site or left stockpiled. m3 8.60 0.00
1.7 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone.only under concrete channel. m2 1.50 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately.
2.1 5 cm thick lean concrete in grade/class C-5 concrete, minimum cement content of 150 kg/m3 :
A. Under ground floor slab m2 6.00 0.00
B. Under masonry foundation wall m2 5.40 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
A. In 20 cm thick slab m2 6.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
To slab edge m2 2.20 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
A. For slab on grade
Dia 10 mm deformed bar Kg 74.04 0.00
Total carried to summary USD 0.00
3.1 50 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 4.28 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
Walls shall be constructed from class 'B' hollow concrete block (H.C.B.). The blocks shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the blocks shall be in such a way that good key for plasterer is obtained on both side.
1.1 Supply and lay 20cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for pointing.Price shall include recessed pointing. m2 9.12 0.00
Total carried to summary USD 0.00
1.1 Supply and fix approved standard pre-painted 0.35mm thick corrugated iron sheet (C.I.S.) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). m2 4.62 0.00
Total carried to summary USD 0.00
3.1 Double-leaf metal door constructed from 40×40×3 mm RHS steel for vertical and horizontal framing, fully welded and braced with similar RHS sections as shown in the Architectural drawings. Door to be infilled with galvanized steel wire mesh 2.5 mm dia. at 25 mm c/c, welded to frame. Include all necessary welding, surface preparation, one coat of primer, and two coats of synthetic enamel paint to all steel surfaces. All work to conform to detailed drawings and relevant standards.
A. Door D1 size 170 x 150 cm. no 1.00 0.00
3.2 Wire mesh covering for pump control switch side walls made of galvanized steel wire mesh 2.5 mm diameter, spaced at 25 mm c/c, fixed securely to RHS structural frame using appropriate clamps or welding as shown on the drawings. The work includes cutting, fitting, welding (where required), surface preparation, one coat of metal primer, and two coats of synthetic enamel paint on all steel members. All materials and workmanship shall comply with the relevant standards and detailed drawings. m2 2.00 0.00
Total carried to summary USD 0.00
4 STEEL STRUCTURE
4.1 Supply, fabricate, assemble, and erect steel structures using RHS and CHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel Structure Column
Steel structure columns are vertical primary load-bearing members, transferring axial loads (and occasionally bending) from trusses to foundations. Since columns are in direct contact with water during cleaning, apply bituminous damp-proof paint at the column base up to a height of 300 mm (30 cm) to prevent corrosion and moisture penetration.
A.1 steel structure column using two RHS sections, 60 × 60 × 3 mm. not welded part single unit. ml 6.90 0.00
B. Steel Structure Column Beam
The beam shall be welded column to column just below the top plate level where truss and column connected. At the end of the beam where there is no steel column. it connected with the existing building it will be fixed with plate at the concrete column/tie beam
B.1 RHS 60 x 60 x 3mm beam ml 6.00 0.00
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards.
C.1 RHS 80 x 60 x 3mm rafter ml 4.00 0.00
D. RHS Purlins 0.00
D.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 100 x 40 x 3mm L= 60mm angle iron. Price include angle iron. ml 5.70 0.00
4.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate size 150 x 150 x 8mm with 4 dia.18 slotted holes for dia. 16 J-bolt No 8.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
PORT SUDAN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.5-Septic Tank & Soak Away Pit-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. Price shall include all working space allowances deemed necessary. m2 25.00 0.00
1.2 Bulk excavation in ordinary soil to a depth not exceeding 150 cm starting from the natural ground level. Note: measurement shall include 25 cm working space for bulk excavation. m3 69.00 0.00
1.3 Ditto but from 150 cm to 300 cm m3 41.00 0.00
1.4 Back fill around retaining wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 27.00 0.00
1.5 Spread coars gravel at the bottom of soak away m3 1.41 0.00
1.6 Ditto as above but spread fine gravel fill between coarse gravel and 0.4 cm average sand fill. m3 0.35 0.00
1.7 Ditto as above but spread 0.4cm average sand fill between fine gravel & 0.2cm diameter fine sand. m3 0.35 0.00
1.8 Ditto as above but spread top layer soak away 0.2cm average fine sand fill. m3 0.55 0.00
1.9 Cart away excavated material from the site as approved by the Engineer. Soil shall be damped more than 1km. m3 115.00 0.00
1.10 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
A) The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube moulds necessary for the purpose and for submitting reports of the tests to the Engineer.
B) Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/ class C-5 concrete, minimum cement content of 150 kg/m3 :
2.1.1 Under septic tank bottom slab m2 13.00 0.00
2.1.2 Unde soak away pit m2 7.60 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In 20 cm thick septic tank bottom slab m2 13.00 0.00
2.2.2 In 20 cm thick septic tank top slab including ring beam m2 10.00 0.00
2.2.3 In 15 cm thick soak away top slab m2 5.00 0.00
2.3 Formwork shall be timbered or steel or a combination of two, sufficient to contain the wet concrete without leakage. Enough to support temporary loading and pressure from placing Compaction or vibration without displacement or appreciable deflection.
2.3.1 To septic tank bottom slab m2 3.20 0.00
2.3.2 To septic tank top slab including ring beam m2 7.00 0.00
2.3.4 To k top slab including ring beam m2 3.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 Bottom Slab
A. Diam 12mm Deformed bar. kg 214.00 0.00
A. Diam 12mm Deformed bar. kg 147.00 0.00
2.4.3 Tie submerged beam
A. Diam 10mm Deformed bar. kg 77.00 0.00
B. Diam 8mm Deformed bar for distribution bar kg 45.00 0.00
2.4.4 Soak away top slab
A. Diam 12mm Deformed bar. kg 75.00 0.00
B. Diam 8mm Deformed bar for distribution bar kg 31.00 0.00
2.10 Allow lump sum amount 60 x 60 cm concrete manhole cover Ls 2.00 0.00
2.11 Supply & fix wooden or equivalent 6,, thick wooden baffle as shown the detail drawing and Engineer’s approval Ls 1.00 0.00
Total carried to summary USD 0.00
3.1 Construct average 60 cm at bottom up to 120 cm & 50 cm thick width thick Basaltic or equivalent stone masonry septic tank retaining foundation wall bedded in cement sand mortar (1:4) below NGL. For septic wall. m3 15.00 0.00
3.2 Ditto as above but 50 cm thick masonry wall for soak away pit m3 9.00 0.00
3.3 Septic tank chamber partition:-Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) with stiffeners bedded and jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. Price shall include plastering m2 2.00 0.00
3.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to internal & external masonry wall surfaces. m2 52.00 0.00
3.5 Ditto as above item but for HCB chamber partition wall. m2 4.00 0.00
3.6 Allow lumps amount of sanitary uPVC work for septic tank inlet, chamber partition and out let pipes to soak away pit. ls 1.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
PORT SUDAN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.6-Cattle Waste Holding Tank
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including 25 cm thick working allowance in each side. m2 21.90 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to an average depth of 150 cm. Note: measurement shall include the net area of the site clearing work. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. m3 32.85 0.00
1.3 Ditto as above item but to a depth above 150 cm but not exceeding 300 cm from reduced ground level. m3 18.61 0.00
1.4 Selected borrow fill around retaining wall with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 24.24 0.00
1.5 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 55.85 0.00
1.6 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described. All works shall be as per the structural general note.
2.1 5 cm thick lean concrete in grade/class C-5, minimum cement content of 150 kg/m3 :
2.1.1 Under bottom holding tank m2 17.00 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In 30 cm thick bottom slab m2 17.00 0.00
2.2.2 In 20 cm thick retaining/shear wall. m2 30.80 0.00
2.2.3 In 20 cm thick suspended top slab m2 11.78 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To bottom slab m2 5.58 0.00
2.3.2 To retaining/shear wall. m2 61.60 0.00
2.3.3 To suspended top slab m2 11.94 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For bottom slab
Dia 12 mm deformed bar Kg 444.00 0.00
2.4.2 For retaining/shear wall
Dia 8 mm deformed bar Kg 89.00 0.00
Dia 12 mm deformed bar Kg 1,025.00 0.00
2.4.3 For floor slab on grade
Dia 8 mm deformed bar Kg 12.00 0.00
Dia 12 mm deformed bar Kg 271.00 0.00
2.5 Internal surfaces of concrete cattle waste holing tank to be thoroughly cleaned and prepared by removing all dirt, laitance, grease, oil, algae, and loose material; all honeycombed, defective, or uneven surfaces to be repaired and made good with approved cement–sand mortar to provide a sound and smooth substrate. Supply and apply a two-component elastomeric cementitious waterproofing coating, potable-water approved, such as Nitocote CM210 or approved equivalent, to floors and walls, strictly in accordance with the manufacturer’s written instructions regarding surface preparation, priming, number of coats, minimum dry film thickness, curing, and protection. All pipe penetrations and exposed services within the tank to be treated with approved bituminous paint or compatible sealing system prior to application of the waterproofing coating. Item to include all materials, labor, tools, equipment, surface preparation, application, testing, protection, and completion of the works. Waterproofing system to be applied by the manufacturer or an approved authorized applicator, providing material and workmanship guarantees to the Employer. m2 38.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
PORT SUDAN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.7-Site Works-Civil
1.1-Hard-scaping USD 0.00
1.2- Soft Scaping USD 0.00
2 Perimeter Fence with Gate USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 Hard-scaping
1.1.1 Clearing and grubbing of existing surface, including removal of vegetation, topsoil, and debris, to a depth of 40 cm and disposal as directed by the Engineer. m2 179.10 0.00
1.1.2 Selected fill to 95% MDD, including watering and rolling as shown the drawing m3 35.82 0.00
1.1.3 Supply, place, spread, water, and compact approved selected gravel material as capping layer to compound surface floor, including leveling, dressing to required camber/slope, and compaction to specified density as per specification and Engineer’s approval. m2 179.10 0.00
1.1.4 Supply and place crushed stone base course (C-4) 10 cm thick, including spreading, watering, and compaction to 95% MDD. m3 30.45 0.00
1.1.5 Supply, lay, and compact 7 cm thick Asphalt Binder Course using approved bituminous mix, laid in well-prepared and compacted layers over an approved base, in accordance with specifications and Engineer’s instructions. m2 179.10 0.00
1.1.6 Edge restraint using concrete curb (15 × 40 cm) including excavation, formwork, placing, and finishing. ml 71.00 0.00
1.1.7 Supply and install resin bound gravel surface comprising washed and dried natural aggregates mixed with UV-stable polyurethane resin, laid to specified thickness over a prepared and approved base, including finishing to a smooth, permeable, and durable surface in accordance with the specifications and Engineer’s instructions. m2 179.10 0.00
1.1.8 Supply and lay hand-dressed natural basalt/granite cobblestones (approx. 150×150×150 mm), tightly packed with joints filled with sand or cement-sand slurry as directed by the Engineer. The work shall includes all the necessary incidental works to complete the work such as surface preparation work. excavation, fill and cement sand slurry as per the detail Ar. drawing. The edge restaint curb stone measured in item 1.1.6. m2 45.50 0.00
Total Carried to Summary (USD) 0.00
1.2 Soft-soaping
1.2.1 Clearing and grubbing of existing surface, including removal of vegetation, topsoil, and debris, to a depth of 60 cm and disposal as directed by the Engineer. m3 37.80 0.00
1.2.2 Supply, place, spread, water, and lightly compact approved loamy (loam) soil for soft landscaping works, free from stones larger than 20 mm, roots, debris, weeds, and other deleterious materials, and suitable for plant growth. Loam soil shall have good drainage and adequate organic content, as approved by the Engineer. The rate shall include supply of soil, transportation, placement to the required levels and thicknesses, watering, light compaction, trimming, leveling, and all labor, tools, and equipment necessary to complete the work as specified. avg. depth 300mm m3 18.90 0.00
1.2.3 Supply, well decomposed animal manure or equivalent organic material to be mixed with the topsoil averagely 300mm and to use in backfilling of planting pits. Price shall include all the necessary works to complete the work. Provide 1kg sample and details of supplier With quotation for Landscape Architect’s approval. m3 18.90 0.00
1.2.4 Provide and plant grass as selected by the landscape architect. price includes grass as per the detail Architectural drawing. m2 63.00 0.00
1.2.5 Maintenance of lawn , grass, trees, shrubs, seasonal flower bed, other plantation and horticultural operations for weeding, watering, spreading of manure, good earth , fertilizers, spray of insecticides, fungicides, hoeing, pruning of tree/shrubs/hedge plants grassing garden swords, anti-termite treatment. Rates to include cost of material, all labor, tools & tackles, cost of manure, earth, fertilizer, pesticides etc. and also providing complete arrangement at site/sites for grass cutting by brand new power run lawn mower with skilled machine man & labor, diesel, lubricant to ensure mowing on barns and by manual labor through garden sward on the slop of under pass of the grass at least 3 times / month complete Month 2.00 0.00
1.2.6 Provide plants specially selected and nursery grown shade trees. Price supply of plants and planting as per the detail Architectural drawing. No 11.00 0.00
Total Carried to Summary (USD) 0.00
2 Galvanized Steel Wire Mesh Perimeter Fence with Gate
2.1 Supply, fabricate, and install galvanized steel wire mesh perimeter fence comprising 60 × 60 × 3 mm RHS vertical posts spaced at 2500 mm centers, fixed in concrete pad foundations, with top and bottom horizontal rails (60 × 60 × 3 mm RHS). The fence infill to be galvanized steel wire mesh (Ø 2.5 mm, 25 × 25 mm grid) securely fixed to the frame.The rate shall include excavation, concrete works, anti-rust treatment, metal painting, and provision of a main gate (2700 mm width) fabricated from similar materials, complete with all accessories, in accordance with specifications and Engineer’s instructions. ml 90.00 0.00
Total Carried to Summary (USD) 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
PORT SUDAN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.8-Site Works-Electrical
ITEM DESCRIPTION UNIT QTY RATE TOTAL
1 Manhole for Electrical Systems
. Construct rectangular double red burnt brick electrical manholes of internal dimensions 800mm × 800mm × 700mm in accordance with the detail drawings and specifications. The manhole shall comprise 250mm thick double red burnt brick masonry walls, internally plastered with cement-sand mortar, a 100mm thick reinforced concrete base slab, and a 100mm thick removable reinforced concrete cover slab complete with flush-type cover, all as approved by the Engineer. The rate shall include excavation to the required depth, disposal/cart-away of surplus excavated material, back-filling and compaction around the structure, supply and placement of concrete, reinforcement, form-work, brick masonry, plastering, curing, and all associated civil works, labor, materials, tools, and incidentals necessary for the complete and proper construction and functioning of the electrical manhole system. Set 7.00 0.00
2 Light Fittings and Lamps 0.00
. Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing. IEC 60969 standards or equivalent and type approved 0.00
LED Solar Street Lights for Outdoor, atleast 15000 Lumens DA high-brightness, all-in-one solar street light for perimeter lighting, powered by sunlight with no electricity costs. Key Specifications Brightness: ≥15,000 lumens (bright as daylight) Light Type: LED (SMD 2835 or CREE 3030 chips) Color: Cool white (6000K–6500K) Solar Panel: 150-watt monocrystalline (charges in 6 hours) Battery: LiFePO4, ≥7-year lifespan, 3-day backup capacity. Operation: Dusk-to-dawn (auto on/off with daylight sensor) Motion sensor (full brightness on movement, dims to save energy) Remote control (adjust brightness, set timers) Weatherproof: IP65 (waterproof, dustproof, works in rain or heat) Material: Aluminum housing, tempered glass cover Runtime: 11 hours after 6-hour charge; up to 18 hours in dim mode Installation: Pole or wall mount (6ms height), no wiring needed Durability: Works in -22°F to 140°F; 50,000+ hour lifespan Warranty: 3–5 years No 8.00 0.00
3 Documentation 0.00
. Engineering, electrical installation as built drawings and O&M manuals. Qualified Set 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
PORT SUDAN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.9-Site Works-Sanitary
SITE SANITARY WORKS
1 SITE WATER SUPPLY SYSTEMS USD 0.00
2 SITE WASTE WATER DRAINAGE SYSTEMS USD 0.00
3 ROOF & SURFACE RAIN WATER DRAINAGE SYSTEM USD 0.00
4 GENERAL ITEMS USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 WATER SUPPLY SYSTEMS
1.1 Site Water Supply Piping Systems
1.1.1 Supply,laying and test Cold drinking water pipes from municipality line to ground water tank(GWT). The pipe shall be PN16 DN50 High Density Polyethylene (HDPE) made of pure PE 100 rawmaterial and be laid in trench as shown in the sanitary site drawing. Provide 100mm thick sand bedding material rammed and tamped and 150mm thick approved material to cover the pipe all as per the typical site trench section and detail.Unit price shall include excavation, backfilling and cart away the excess quantity with all assistance civil works and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 10.00 0.00
1.1.2 Supply,laying and test Cold drinking water pipes from ground water tank(GWT) to transfer pump and to elevated water tank(EWT). The pipe shall be PN16 DN32 High Density Polyethylene (HDPE) made of pure PE 100 rawmaterial and be laid in trench as shown in the sanitary site drawing. Provide 100mm thick sand bedding material rammed and tamped and 150mm thick approved material to cover the pipe all as per the typical site trench section and detail.Unit price shall include excavation, backfilling and cart away the excess quantity with all assistance civil works and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 12.00 0.00
1.1.3 Supply,laying and test Cold drinking water pipes from gelevated water tank(EWT) to building block entrance where branched to water points (usable water supply)and nearby drainage lines (for overflow & washout piping). The pipe shall be PN10 DN40 PPR made of pure original rawmaterial and be laid in trench as shown in the sanitary site drawing. The unit price shall include piping bottom drain with valves piping system from EWT connected with overflow and connected to near by drainage ditch, air vent with insect screen and all support fixting work with related civil works. The unit price shall also consider and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 20.00 0.00
1.2 Supply and fix chrome service valves/isolation valve of approved standard before wet areas, or hand wash basins, water closets and other fixtures. Complete with unions, elastic water proofing, hand wheels of normal quality and with all other necessary accessories.
1.3 Construct standard a double brick wall,R.C base slab & R.C cover valve chamber compatible to valve size at specific position shown on the drawing with the respective PN6 bronze isolating valve.The price shall include excavation of a pit, cart away and backfilling.
1.3.1 Valve chamber with DN : variable isolation valves. № 4.00 0.00
1.4 Supply, installation, testing, and commissioning of domestic cold-water meter of multi-jet or volumetric type, suitable for potable water application in the animal health clinic water distribution system, complying with ISO 4064 / OIML R49 standards.Water meter shall be of DN50 nominal size, with brass or epoxy-coated ductile iron body, sealed dry dial register, and corrosion-resistant internal components. The meter shall be Class B or R80 accuracy, with a nominal working pressure of 16 bar, and maximum temperature 30°C.Each meter shall include couplings, strainer, and non-return valve, islation valve at each end and be installed in an accessible, ventilated, and protected meter chamber.All meters shall be factory-calibrated, certified, and permanently marked with serial number, flow class, size, and manufacturer identification. № 1.00 0.00
1.4 Water Reservoirs
1.4.1 Elevated water tank[EWT]
Supply, install, and commission a high-quality fiberglass (or equivalent) water tank with a nominal capacity of 2,500 liters for potable water storage, elevated 6 meters above ground on a support structure as per the provided sanitary and structural detail drawings. Tank Specifications: Material: Fiberglass reinforced plastic (FRP) or equivalent, approved for potable water storage, compliant with relevant standards ( BS EN 13280 or equivalent). Capacity: 2,500 liters (nominal). Design: Vertical seated(bottom diameter < 2m , suitable for external exposure with UV-resistant coating to withstand harsh weather conditions. Accessories: Manhole: Watertight manhole (minimum 600 mm diameter) with a lockable, weather-resistant cover to prevent contamination and ensure safety. Overflow Pipe: Minimum DN50, directed to a near by rain water drainage point with insect-proof mesh. Level Sensor: Automatic water level sensor/controller to start/stop the transfer pump. Inlet Pipe: Minimum DN32, fitted with a PN16 bronze gate valve. Outlet Pipe: Minimum DN40, fitted with a PN16 bronze gate valve and an expansion joint to accommodate to absorb any pipe movement. Drain Pipe: Minimum DN50, fitted with a PN16 bronze gate valve for complete tank drainage, directed to a designated drainage point. Fittings: All pipes and fittings shall be corrosion-resistant, suitable for potable water, and compliant with relevant standards (BS EN 545 or equivalent). Set 1.00 0.00
1.4.2 Ground water tank[GWT]
Supply, install, and commission a high-quality fiberglass (or equivalent) water tank with a nominal capacity of 5000 liters for potable water storage, at ground level as per the provided sanitary and structural detail drawings. Tank Specifications: Material: Fiberglass reinforced plastic (FRP) or equivalent, approved for potable water storage, compliant with relevant standards ( BS EN 13280 or equivalent). Capacity: 5000 liters (nominal). Design: Vertical seated(bottom diameter < 2m , suitable for external exposure with UV-resistant coating to withstand harsh weather conditions. Accessories: Manhole: Watertight manhole (minimum 600 mm diameter) with a lockable, weather-resistant cover to prevent contamination and ensure safety. Overflow Pipe: Minimum DN50, directed to a near by rain water drainage point with insect-proof mesh. Level Sensor: Automatic water level sensor/controller to start/stop the transfer pump. Inlet Pipe: Minimum DN50, fitted with a PN16 bronze gate valve. Outlet Pipe: Minimum DN32, fitted with a PN16 bronze gate valve and an expansion joint to accommodate to absorb any pipe movement. Drain Pipe: Minimum DN50, fitted with a PN16 bronze gate valve for complete tank drainage, directed to a designated drainage point. Fittings: All pipes and fittings shall be corrosion-resistant, suitable for potable water, and compliant with relevant standards (BS EN 545 or equivalent). set 1.00 0.00
1.5 Potable Cold Water Pumping system
1.5.1 Supply, fix, test and commission approved quality duplex vertical inline water pumps to push potable water to elevated water tanks to be distributed to every demanding buildings of the compound .As per the manufacturer's instruction and drawing shown . Price shall include all the necessary valves( one-way and stop valves), water hammer arrestor , common base plate ,automatic level control sensors & switches to start/off & to protect pumps from dry running & control panel .The price shall include all the necessary accessories required for the proper operation of the system but not specified or shown on the drawing. The pump shall be equiped with a single-phase transfer pump control board to manage water levels in an elevated water tank and ground water tank, featuring a compact IP65-rated enclosure (stainless steel or powder-coated mild steel), industrial-grade PLC, 4-inch touchscreen HMI for real-time monitoring and manual override, ultrasonic or float-type level sensors (2 nos. per tank) for accurate water level detection, control logic for automatic pump start/stop based on setpoints with sequential operation to minimize load, thermal overload relays, dry run protection via sensors or current monitoring, single-phase failure protection, surge arrestors, flame-retardant copper wiring, dedicated earthing, real-time pump status and alarm monitoring (high/low water levels, pump faults) on HMI, compliant with IEC standards and local regulations, complete with installation, testing, as-built drawings, operation manuals, training, and a 2-year warranty, designed for a 10-year operational life. Flow rate[LPS] = 0.694 @ 10 meter head Reference Model : Brand: DAB Model:KLPE 40-1200 with respective control systems and sensors. Set 1.00 0.00
1.5.2 SUPPLY, INSTALL, TEST & COMMISSION MUNICIPAL WATER CONNECTION TO GROUND WATER TANK Scope includes but not limited to: • Supply and installation of HDPE PE100 PN16 DN50 pipe (maximum 20 m total trench length from municipal main to groundwater tank inlet). • Supply and installation of municipality-approved water meter (DN50, with calibration certificate and serial number registration). • Supply and installation of isolation valve (gate/ball type, PN16, DN50, with flange or compression ends). • Supply and installation of all necessary fittings (elbows, tees, reducers, flanges, couplings, anchor blocks, thrust blocks, gaskets, bolts, and nuts). • Supply and installation of above-ground fence enclosure (galvanized steel or powder-coated mild steel) around the meter & valve assembly, with lockable access door, minimum 1.2 m height. • Excavation, backfilling, and compaction of trench (depth as per local municipality code, including sand bedding and warning tape). • Connection to municipal main (including tapping, saddle, or tee as required) and connection to tank inlet (with appropriate adapter). • Pressure testing (1.5x working pressure for minimum 24 hour), flushing, and chlorination/disinfection of pipeline. • All civil works (concrete pads for meter/fence posts, gravel base, and surface restoration to original condition). • All permits, inspections, and approvals from the local municipality (including meter registration and final sign-off). • As-built drawings and operation/maintenance manuals submission. Note: All materials shall be new, certified, and compliant with municipality standards. Contractor to verify all site dimensions and municipal point of connection prior to execution. ls 1.00 0.00
Total Carried to summary USD 0.00
2 WASTE WATER DRAINAGE SYSTEMS
2.1 Providing, laying and jointing of internal uPVC PN-10 waste pipes with all uPVC pipe fittings including jointing with solvent cement joints and testing of joints etc. according to where shown on the drawings.Complete with all the necessary fittings. Provide cleaning detail for all waste water riser pipes as per the detail drawing.
2.1.2 Diameter 110mm ml 14.00 0.00
2.1.3 Diameter 160mm ml 37.00 0.00
2.1.3 Diameter 300mm ml 14.00 0.00
2.1.4 Construct rectangular manhole out of 250mm thick double brick walls,internal dimension 600mm x 600mm x 850mm (average depth),internally plastered with three coats of cement/sand mix ratio1:3 ,on a base of precast R.C slab of size ,1300mm x 1300mm x100mm , including benching and bottom channeling with mass concrete.Slab shall be reinforced with dia.8mm reinforcement bar c/c 130mm bothways. Provide 150mm thick granular materials beneath the slab,on a compacted earth . Manhole shall have precast R.C cover slab, each,size, 740mm x 740mm x 100mmreinforced with diameter 8mm steel barc/c140mm bothways,including diameter 14mm steel ring handle with supporter bar all in accordance with the given detail drawings .Unit price shall include excavation of the pitto a depth of 800mm (average) and cart away of the excavated soil. № 8.00 0.00
2.1.5 Ditto No 2.1.4 but size(length x width x depth)[mm]= 400 x 400 x 400 gully trap for gray water drainage № 3.00 0.00
Total Carried to summary USD 0.00
3 ROOF WATER DRAINAGE SYSTEM
3.10 Construct a rectangular open channel designed to collect and convey storm water runoff from around the building perimeter. The channel is made of 20cm thick masonry bed, 40cm thick side masonry wall and whenever the walk way, ramp and car way crossing the top part will be covered with pre case concrete cover. The internal part of the channel shall be plastered. The work shall include excavation, cart away , fill, masonry bed, wall, plastering , pre-cast concrete cover at crossing and all incidental work to complete work as per the project’s detailed drawings. The channel longitudinal slope of 1% (1:100) shall be maintained. Where the natural ground slope exceeds 1%, the contractor shall follow the greater natural ground slope to ensure positive drainage and avoid ponding. ml 90.00 0.00
Minimum Ditch-: SIZE[mmXmm] = 225 X 200
3.20 Ditto No 2.1.3 but for roof and surface water drainage system. № 10.00 0.00
3.30 Ditto No 2.1.4 but for roof and surface water drainage system. № 2.00 0.00
3.40 SURFACE WATER DRAINAGE CONNECTION TO ROADSIDE DRAINAGE LINE Scope includes but is not limited to: • Supply and installation of DN300 uPVC pipe (Class/SN as per local municipality standard for underground non-pressure drainage) from the manhole inside the clinic compound to the roadside drainage line. Total length to be verified on-site. • Pipe shall be laid at a gradient of 0.5% to 1% (1 in 200 to 1 in 100) to ensure self-cleansing velocity and prevent siltation. • Connection to existing manhole inside clinic compound (600mm x 600mm internal size, with invert level above road side drainage invert). Includes breaking into manhole wall, making good, and providing a proper connection. • Connection to roadside drainage line (standard road side channel/drain). Includes forming a proper junction at the outfall point. The connecting pipe's invert level shall be set above the soffit (crown) of the roadside drain to prevent backflow during high-flow conditions in the main drain. • Supply and installation of all necessary fittings (bends, junctions, couplings, adaptors) as required for directional changes and connections. • All civil works: Excavation (including breaking existing surfaces), trenching, pipe bedding (sand/gravel), backfilling, compaction, and surface restoration to original condition. • Testing of the installed pipeline by means of water or air testing to ensure leak-tightness prior to backfilling. • All necessary permits, approvals, and inspections as required by the local municipality for connection to the public drainage system. Note: Contractor to verify all site levels, invert levels of the existing manhole and roadside drain, and confirm the required slope is achievable before commencement. All works to be carried out as per local municipality standards and approved drawings. ls 1.00 0.00
Total carried to summary USD 0.00
4 GENERAL ITEMS
4.1 Allow for Testing and commissioning of the entire plumbing installation by a Chartered Mechanical Engineer and obtaining a Test Certificate (3rd party testing to approval of the Engineer) including all off-site and factory testing; inspections to demonstrate compliance with relevant standards, operating the completed installation and submitting all relevant test records and authority approval. LS 1.00 0.00
4.2 All sanitary fittings supplied shall be provided with a minimum 5 year warranty, issued jointly and severally by the local supplier and the manufacturer. LS 1.00 0.00
4.3 Allow for preparation of Operationa and Maintenance Manual including site users training for the O & M Maual of all plumbing and mechanical appliances. LS 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
PORT SUDAN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bill No.10-Signage
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 Directory Signs
Design, supply and install international standard Boy's, Girl's & PWD Toilet directional sign complete with pictogram (Girl's, Girl's & PWD toilet sign symbol) plus directional arrow that leading to the toilets. The sign shall also consist text “Boy's , Girl's & PWDToilet.” Sign shall be minimum size 300 mm × 400 mm, high quality tin: tin sign with retro design, metal tin, long-term use, not easy to damage, smooth surface, ...with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 1.00 0.00
2 Room Identication Signs
Design and supply signage with room number in accordance with this specification and as directed by the Architect. The material shall be made of 3-5mm thick wall mounted Acrylic signs. The size shall be 250mm x 30mm and letter height shall be 50-70mm for room number, 25-40mm room name letters and braille and tactile characters where applicable. The color and contrast between the text and background shall be high and the color shall be consistent with the veternary clinic branding (if any) or as per the Architect approval. The topography and information shall be Room number: Bold, large font (sans serif preferred), Room function/name: Smaller font beneath the number (e.g., Room 101 – Office) and Braille/tactile lettering placed below the printed text. The signage shall be fixed to the wall at 1.4–1.5 m above floor to centerline of sign on the latch side of the door, or directly on the door if wall space is not available and it shall be fixed with secure concealed fasteners or adhesive (depending on wall/door material). The supplier shall produce and submit Mock-ups for approval before mass production. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect.
2.1 Isolation Room No 1.00 0.00
2.2 Office No 1.00 0.00
2.3 X-ray room No 1.00 0.00
2.4 Preparation room No 1.00 0.00
2.5 Electric Room No 1.00 0.00
2.6 Rest rooms and Janitors with pictogram of gents, ladies and PWD No 4.00 0.00
2.7 Treatment room No 1.00 0.00
2.8 laboratory No 1.00 0.00
3 Safety and Compliance Signs
4.1 Design, supply and install Emergency Exit Sign in accordance with this specification and as directed by the Architect. The material shall be made of flame-retardant, impact-resistant ABS clear acrylic plate and shall comply with BS EN ISO 7010 Exit Symbol (E001) and shall have Multi-installation system: Hanging, wall or surface mounted depending on the location. The size of the letter height shall be minimum 150mm with a stroke width 19mm, color contrast to be white letters on green background and the sign shall consist pictogram of running man symbol + directional arrow that leading to exit doors depending the location of the Emergency sign plan on the drawing. The sign shall support internally illuminated and visible in smoke and low light and are powered by dual power 220-240V AC (primary), automatic 90 minutes minimum battery backup (Lithium-ion battery).The sign shall be fixed to exist access point at 2.00–2.50 m above floor level. The supplier shall produce and submit Mock-ups for approval before mass production or procurement. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect. No 4.00 0.00
4.2 Design, supply and install Entrance Sign in accordance with this specification and as directed by the Architect. The material shall be made of flame-retardant, impact-resistant ABS clear acrylic plate and shall comply with BS EN ISO 7010 Exit Symbol (E001) and shall have Multi-installation system: Hanging, wall or surface mounted depending on the location. The size of the letter height shall be minimum 150mm with a stroke width 19mm, color contrast to be white letters on green background and the sign shall consist text+ directional arrow that leading to entrance.The sign shall be fixed to entrance access point at 2.00–2.50 m above floor level. The supplier shall produce and submit Mock-ups for approval before mass production or procurement. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect. No 3.00 0.00
4.3 Supply and fix 3mm rigid PVC/acrylic Fire Extinguisher sign (300mm x 100mm) with 50mm high ISO-compliant white lettering on red background, including all fixings and installation. No 7.00 0.00
4.4 Supply directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. Supply and install directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. No 1.00 0.00
4.5 Supply emergency assembly point safety sign complete with standard ISO 7010 pictogram (E007: four people symbol) and text “EMERGENCY ASSEMBLY POINT.” Sign shall be fabricated from 3 mm thick photo luminescent rigid PVC or aluminum composite panel, minimum size 600 mm × 600 mm, with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
PORT SUDAN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.10-Day Works
1 LABOUR USD 0.00
2 MATERIAL USD 0.00
3 PLANT USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
(ALL PROVISIONAL)
In accordance with the Conditions of Contract, the Contractor will be paid day work rates for extra work that cannot properly be measured and valued, and the Contractor is to insert in the space provided below the basic rates and costs of labour,materials and plant as described hereunder:-
1.1 MASON hours 1 0.00
1.2 CARPENTER hours 1 0.00
1.3 SCAFFOLDER hours 1 0.00
1.4 JOINER hours 1 0.00
1.5 PLUMBER hours 1 0.00
1.6 ELECTRICIAN hours 1 0.00
1.7 PLASTERER hours 1 0.00
1.8 PAINTER hours 1 0.00
1.9 LABOURER hours 1 0.00
TOTAL in USD 0.00
1.10 To the basic net rates of labor used for work carried out on day works, an addition 25% percent which is to include for task work and incentive schemes, tools, standing, scaffolding, supervision, insurance, transport profit and overheads.
To collection of Labour Day works 0.00
2.1 Cement Per Tonne 1 0.00
2.3 Aggregate (grade 25 - 5mm) m3 14 0.00
2.4 Steel reinforcement
(i) Mild steel bar Kg 1 0.00
(ii) High tensile bar Kg 1 0.00
2.5 Timber formwork Per SQ.M 1 0.00
2.6 Paint, Gloss Per 4 Litres 1 0.00
2.7 Paint, Emulsion Per 4 Litres 1 0.00
2.8 Mahogany Varnish Per 4 Litres 1 0.00
2.9 100mm diameter uPVC rainwater downpipe 6M Per Each 1 0.00
2.10 Ditto bends Per Each 1 0.00
2.11 Ditto offsets Per Each 1 0.00
2.12 Ditto watershoe Per Each 1 0.00
2.13 Fixing brackets Per Each 1 0.00
2.14 Fixing screws Per Packet 1 0.00
2.15 75mm thick x 375mm wide weather/throated cills Per M 1 0.00
2.16 4 mm Clear sheet glass Per SQ.M. 1 0.00
2.17 100mm long Flush bolt Per Each 1 0.00
2.18 Indicator Signage Per Each 1 0.00
2.19 400mm x 200mm x 100mm hollow concrete blocks Per 1000 1 0.00
2.20 300mm x300mm x 8mm Ceramic floor tiles Per SQ.M. 1 0.00
2.21 150mm x 150mm x 6mm white glazed wall tiles Per SQ.M. 1 0.00
2.22 25mm x 3mm earth copper tape Per M 1 0.00
2.23 35mmsq bare copper cable Per M 1 0.00
2.24 6mmsq bare copper cable Per M 1 0.00
2.25 2.5mmsq. TWE copper cable Per M 1 0.00
2.26 2.5mmsq. SC PVC-I copper cable Per M 1 0.00
2.27 4.0mmsq. SC PVC-I copper cable Per M 1 0.00
2.28 10.0mmsq. 3C PVC-SWA-PVC copper cable Per M 1 0.00
2.29 20mm diameter galvanised steel tubing 6M Per M 1 0.00
2.30 20mm diameter galvanised steel tee Per Each 1 0.00
2.31 20-15mm diameter reducer Per Each 1 0.00
2.32 110mm diameter uPVC soil pipe 6M Per Each 1 0.00
2.33 50mm ditto waste pipe 6M Per Each 1 0.00
2.34 110mm ditto single branch access Per Each 1 0.00
2.35 50mm ditto sweep tee Per Each 1 0.00
2.36 Single bowl, single drainer stainless steel sink size 2000 x 600mm Per Each 1 0.00
To Collection 0.00
2.37 To the basic nett rates of materials used for work carried out on dayworks, an addition of 25% which is to include for unloading and storing as necessary, the use of hand plant, and machinery etc. available on site, profit and overheads.
To collection of Material Day works 0.00
3.1 Portable Compressor with 2 breakers or equivalent with 1500 mm hoses and reels hours 40 0.00
3.2 Damp Truck (0.75 tonne) hours 40 0.00
3.3 Lorry seven tonne tipper hours 40 0.00
3.4 Concrete Mixer (14/10) complete for weight batch mixing hours 40 0.00
3.5 50 mm self priming centrifugal pump with hose and ancillary equipment hours 40 0.00
3.6 Concrete Vibrators hours 40 0.00
To Collection 0.00
3.7 To the basic rates of plant used for work carried out on dayworks, an addition of 25% per cent, which is to include for driver and/or attendance, fuel and consumable stores supervision, insurance, road licence,profit and overheads.
To collection of Plant Day works 0.00
Name of Signatory:
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Exavation Work
ITEM TYPE SIZE No M3
Exavation & Earthwork
1.01 site clear
cad area including appron,ditch
1.02. Bulk Excavation to reduce level
1.03. Footing Excavation
1.04. ditto but from 1.50-3.00m
1.05.Trench Excavation
with 0.15 allowance each side
1.05. Back fill under hard core
ddt stone masonry wall
1.06.Ditto but around footing
Excavation Volume
ddt lean concrete
ddt footing pad
ddt column 0.00
1.07.Ditto but around masonry
with 0.25 allowance each side
1.08. Cart away
1.09. hard core
1.10. Dewatering
3.01. construction joint
10mm thich joint filler/sila or fiber board
4. Masonry Item
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Sub-Structure Concrete
CONCRETE FORM WORK
Type Size No Total Size Total
2.1. Lean Concrete
Total 118.86 m2
Under masonry wall
Under hard core
2.2 C -25 CONCRETE
Foundation Column
Total 5.04 67.20
200mm thick slab
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Super-Structure Concrete
CONCRETE FORM WORK
1.1. C-250 Concrete
A. Elevation Column
From Ground-roof floor
150mm Concrete gutter
Total 9.05 m3 129.05 m2
100mmSun breaker
Total 22.11 m3 23.32 m2
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Architectural
ITEM TYPE SIZE No Total
2.01. 20cm thick H.C.B wall screening
2.01. 20cm thick H.C.B wall
ddt opening 0.00
3. Roofing Work
3.04. Valley gutter
Gutter light wt concrete
Gutter water proofing
B. Steel Structure Beam
C. RHS Truss system
C.1 RHS 60 x 60 x 3mm upper and lower member
Total length 188.60
Unit Wt. for the section 5.37
Total Kg 1,012.67
C.2 RHS 50 x 50 x 3mm upper and lower member
Total length 24.00
Unit Wt. for the section 4.43
Total Kg 106.26
C.3 RHS 40 x 40 x 3mm Diagonal & verical member
Total length 181.85
Unit Wt. for the section 3.49
Total Kg 633.82
D.1 80 x 4 x 3mm fixed
Total length 434.10
Unit Wt. for the section 5.37
Total Kg 2,330.86
Base plate 200 x 200 x 6mm
Total plate 56.00
7. Finishing work
6.0 Two coats of plastering
Internal HCB wall plastering
to receive gypsum chuck
ddt opening 0.00
External plastering
ddt opening 0.00
Bill No.2 Staff Residence Block
For Ariya kayisa Primary School
Summary of Reinforcement for Sub-structures & Super-Srructure
Foundation Footing
Foundation Column
Ground Floor Beam
Ground Floor Slab
Super-Structure
Elevation Column
REINFORCING BAR SCHEDULE
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Date , Sep 28,2025
Bill No.-2-Staff Residence Block Consultant;- UNOPS-ETMCO
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Foundation Colum --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Foundation Column --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Ground floor slab --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
internal partiton area --- --- --- --- --- --- --- ---
REINFORCING BAR SCHEDULE
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Date , Sep 28,2025
Bill No.-2-Staff Residence Block Consultant;- UNOPS-ETMCO
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Elevation Column --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
United Nations Office for Project Services
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
Tender Reference:
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR),
CONSTRUCTION WORKS FOR VETERNARY PROJECT
At AL WALEEB & GUNUB
BILL OF QUANTITIES (BOQ)
- Bill Nr.1 - Mobilization
- Bill Nr.2 to 10-Civil, Electrical & Sanitary Works-BoQ
- Bill Nr.11 - Day Works
NOTE: It is a MANDATORY requirement for bidders to complete and return both this excel BOQs and their respective duly signed pdf for further reference
Failure to complete all sections of the BOQ may result to automatic disqualification of your bid.
PREAMBLE TO BILLS OF QUANTITIES
1 Priliminary Condition
1.1 This Specification shall be read in conjunction with the Particular Technical Specifications provided under each work discipline, as well as the latest edition of the Sudan Standard Technical Specifications for Building Works, or any other internationally recognized standards commonly adopted in Sudan.
1.2 The Bill of Quantities (BoQ) shall be measured in accordance with the latest edition of the Sudan Standard Methods of Measurement for Building Works.Pro Memoria (PM): Indicates that the cost of the item is deemed to be included and distributed within other related work items in the BoQ. No separate payment will be made.Lump Sum (LS): Indicates that the item is priced as a fixed total amount, with no adjustment or variation permitted to the total price regardless of actual quantities executed.
1.3 The contractor has fully understood the scope of works by minutely having studied the drawings and Bill of Quantities with specifications, and by having visited the site. He will, on his own initiative and before the works start and in his best ability, notify the consultant of works which are not mentioned in the BoQ and/or the specifications and/or the drawings, which are necessary to execute the construction as envisioned in the drawings. Thus, after the works have started, the contractor cannot rely on incompletions in the consultants' work to make claims of any kind. Indeed, the contractor will add upon the specifications according to his own insight and professional experience. If there are works to be done which are not specified in this BoQ, it is up to the consultant to decide wether these works are variation works which need change orders, or wether these works are included in the items and their prices in the BoQ.
1.4 The contractor has to execute all works which have a direct or indirect impact on safety and availability of infrastructure (water, sewage, electricity, …) in as short a period as feasible.
1.5 The contractor will secure the structural and functional integrity of the exsiting buildings nearby the project site during construction work as well as of the building’s surroundings such as but not limited to public road, gate, lawn. He will study and execute the necessary scaffolding to support the building, in order to avoid any cracks, settlements, or crumbling. This scaffolding to support the building during the works are included in the prices given. Debris will be cart away to certified debris places in the area. In no way, debris will be stored, buried or burned on site.
1.6 After the works, the contractor will do a thorough cleaning of the construction site, this means cleaning of all excess mortars, cement bags, excess blockwork, excess tile jointing – in short any construction remnant which hinders the proper use of the house upon site hand-over.
NHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
1.7 In general the contractor will put his professional experience and craftsmanship to work, in order to get a holistically well-constructed building, to the highest and most up-to-date standards of Sudan Construction & international Culture.
2 Organisation of Construction Site
This includes all necessary preparations to execute the works; at least from the beginning until the end of the works; according to the best knowledge and experience of the contractor: at least conform local standards.
The objectives of the Bill of Quantities are
(a) to provide sufficient information on the quantities of Works to be performed to enable bids to be prepared efficiently and accurately; and
(b) when a Contract has been entered into, to provide a priced Bill of Quantities for use in the periodic valuation of Works executed.
In order to attain these objectives, Works have been itemized in the Bill of Quantities in sufficient detail to distinguish between the different classes of Works, or between Works of the same nature carried out in differently or in other circumstances which may give rise to different considerations of cost.
4 The Bills of Quantities for the Works comprise the following:
Preamble to Bill of Quantities
List of principal Quantities
Bill Nr. 1 Mobilization
Bill Nr. 2 - 10 Civil, Electrical Installation & Sanitary Installation
Bill Nr. 11 Day Works
5 The Contractor’s unit rates in these bills are to cover supplying of materials, taking delivery, transporting, loading and off loading inspection, storage, stacking, landing, preparation, installation including provision of all labour, requirement false work, temporary support, surface preparation and testing of the works. The rates shall include all applicable taxes and duty. The cost of testing of the materials to be used in the works unless otherwise provided is to be included in the rates of the respective Bill items.
6 Measurement for payment shall be for the complete installation and having passed all necessary tests.
7 Work shall not be executed on a Day work basis unless ordered in writing by the Consultant on approval by the Employer. The rates entered in the Day works Bill of Quantities shall apply to any quantity of Day work instructed by the Consultant. Nominal quantities have been indicated against each item to permit the extended total to be carried forward to the Grand Summary.
8 “Rates and prices shall be inserted in the rate and total columns of the Bill of Quantities in USD
9 Bills of Quantities are to be read in conjunction with the Instructions to Bidders, the Conditions of Contract Data, the Specifications and the Drawings. The quantities stated against each item in the Bills of Quantities, with the exception of those items specifically marked ‘sum’, are the estimated quantities of the Work to be executed by the Contractor in fulfillment of his obligations under the Contract.
10 The Contractor is required to check the number of the pages and should any be found to be missing or in duplicate he must inform the Engineer at once and have the same rectified.
11 No liability whatever will be admitted or claim allowed in respect of errors in the Contractor’s tender due to mistakes in the Bills of Quantities which should have been rectified in the manner described above.
12 The contractor shall not alter or otherwise qualify the text of these Bills of Quantities. Any alteration or qualification made without authority will be ignored and the text of the Bills of Quantities as printed will be adhered to.
13 Each item in the Bills of Quantities is to be priced. If any items are left un-priced it will be assumed that the value of the work described there under is elsewhere allowed for. The prices and rates to be inserted in the Bills of Quantities are to be fully inclusive of all costs and expenses which may be required for the construction of the work described, together with general risks, liabilities and obligations set forth or implied in these documents.
14 In no case will any claim for expenses incurred by the Contractor in preparation of this Tender be allowed.
15 The Contractor is solely responsible for the accurate ordering of materials in accordance with the Specifications, Drawings and Engineer’s Instructions and no claim for any loss or expense will be entertained for orders for materials based on the Bills of Quantities.
16 The quantities given in the Bills of Quantities are estimated and no claim by the Contractor for the final quantities being larger or smaller than the quantities given in the Bills of Quantities will be permitted except alows in accordance with the particular of the Conditions of Contract.
17 The dimensions given in the Drawings are generally in millimeters unless otherwise indicated. Levels are given in meters.
18 The term ‘provide’ or ‘supply’ used for any item shall be deemed to include transport to site, handling, storage and fixing complete, and the Bidder’s rate shall include for this.
19 The following abbreviations have been used in the Bills of Quantities:-
ml metre linear
m2 square metre
PS provisional Sum
Set Complete set of work with accessories & components
lot Complete set of work with accessories & components
PS provisional Sum
USD United States Dollar
uPVC un-plasticized poly vinyl chloride
HDPE high density polyethylene
GMS galvanized mild steel
PPE personal protective equipment
ASTM American society for testing & material
GW well-graded gravel
GP poorly-graded gravel
GM silty gravel, gravel-sand-silt mixtures
GC Clayey gravels, gravel sand-clay mixtures
SW well graded sands
SP poorly graded sands
SM silty sand, sand -silt-mixtures
SC clayey sands, sand-clay mixtures
AASHO American Association of State Highway and Transportation Officials,
ACI American Concrete Institue
RHS rectangular hollow section
PVD Physical Vapor Deposition
HCB hollow concret block
CBR california bearing ratio
MC medium curing
SDB sub distribution board
PDB pump distrbution board
20 Unless otherwise provided there are no separate measurement items for Contractual requirements. The Contractor is deemed to have included his costs for the Contractual requirement
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
AL WALEEB & GUNUB VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
GRAND SUMMARY Amount in USD
1 Bill Nr.1 - Mobilization USD 0.00
2 Bill Nr.2 -Model Veternary Building-
2.1 - Civil Work USD 0.00
2.2 - Electrical Installation Work USD 0.00
2.3 -Sanitaryl Installation Work USD 0.00
3 Bill Nr.3 - Solar PV USD 0.00
4 Bill Nr.4 Pump Control Swith Shed with platform-Civil Work USD 0.00
5 Bill Nr.5 Septic Tank & Soak Away Pit-Civil Work USD 0.00
6 Bill Nr.6 Cattle Waste Holding Tank-Civil Work USD 0.00
7 Bill Nr.7 Site Works-Civil USD 0.00
8 Bill Nr.8 Site Work-Electrical USD 0.00
9 Bill Nr.9 Site Work-Sanitary USD 0.00
10 Bill Nr.10 Signage USD 0.00
GRAND TOTAL USD 0.00
11 Bill Nr.11 - Day Works USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
AL WALEEB & GUNUB VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill Nr. 1- Mobilization & Existing Condition
1 SIGN BOARD USD 0.00
2 SITE SUPERVISOR TRANSPORTATION USD 0.00
3 SAFTEY HARNESS & PROTECTION USD 0.00
4 SAFTEY & SECURITY OF WORKS USD 0.00
5 SHOP DRAWINGS USD 0.00
6 Existing Condition/Demolishing Work USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 Contractor to provide a Project Identification sign size (200 cm × 200 cm), Contractor to submit shop drawing for UNOPS Engineer Approval, also 2 safety signs (120 cm x 120 cm). Safety signed to be submitted to approval of Engineers. LS 1.00 0.00
2 Site Supervisor Office & Transportation
2.1 Providing office for supervisor team completed with office Desk LS 1.00 0.00
3 Safety Harness and Protection
3.1 2 No (Minimum) Safety Harness with lanyards , 3 fire powder 6Kg fire extinguishers, and selection of gloves & safety glasses to be kept in UNOPS Office at all time, also contractor should in his price include the cost of providing all his staff and work force with suitable PPEs ( i.e. Hard Hat, Safety Boot, Dust Masks, Safety Vests and Safety Glasses) Ls 1.00 0.00
4 Safety & Security of Works
4.1 Allow for providing safety and security for the Works and material as per the requirement laid under the Contract, including security lighting, lockable or open material storage areas, engaging security guards and / or any other measures as necessary. Cost shall include Road Safety awareness, and public traffic flow management during construction. LS 1.00 0.00
4.2 Providing, erecting, maintaining, and removing temporary site hoarding/fence made of corrugated iron sheets (C.I.S.) securely fixed to eucalyptus posts, including all posts, bracing, fixing materials, excavation, installation, maintenance, dismantling, and disposal upon completion. The hoarding shall be approximately 2.4 m high and installed along the site perimeter adjacent to the public road and other accessible areas, as directed by the Engineer, to prevent unauthorized access and ensure site security. ml 93.00 0.00
5 Shop Drawings
5.1 Allow for prepare and submit to the Engineer's Representative a complete set of Shop Drawings, as required to the specified scale(s), giving all details, as required by the Engineer's Representative, for the work executed. Submission shall be in 3 sets as hard copies, color printed on A1 size paper and 01 set of soft copies in AutoCAD compatible version in a compact disc. LS 1.00 0.00
6 Existing Condition/Demolishing
6.1 Demolishing
The work shall be performed by qualified personnel who have ample experience in demolishing and safety work in order to avoid risk in the existing structure and in human life. Any useful dismantled materials shall be kept in proper manner and submitted to the client after proper cleaning. The contractor shall take all the responsibility of worker discipline in order to avoid disturbance and security issues at the work place and the entire compound. The contractor shall protect the existing area with approved standard plastic or other protective cover. Contractor is advised to investigate the scope of dismantling work before filling in prices.
The rate shall include breaking, cutting, dismantling, loading, hauling and disposal of all demolished materials, debris and unsuitable materials to an approved disposal area designated by the Engineer/Employer, including all labor, tools, plant, equipment, lifting and hauling facilities, water, temporary works, protection of adjacent structures and services, dust suppression, cleaning of the site, and all other incidental works necessary to complete the demolition safely and entirely in accordance with the drawings, specifications and Engineer’s instructions.
The contractor shall take all necessary precautions to prevent damage to adjacent buildings, utilities, pavements and other retained structures. Salvageable materials, if any, shall be separated and handed over to the Employer as directed by the Engineer. The area shall be left safe, clean, level and ready for subsequent construction works. The contractor shall submit methodology and work plan for approval by the Engineer before commencing the Works. contractor is advised to go through the detail of the building structure during pre-bid site visit.
A Demolition and complete removal of the Existing Building “A” as identified in the Architectural Drawing Legend, having a single story built up dimension of 6,300 mm × 4,200 mm and an average height of 2.80 m, comprising two rooms. The work shall include, but not be limited to, all necessary preparation, protection, temporary support and safety measures; dismantling and demolition of approximately six (6) reinforced concrete columns, grade beams, roof/tie beams and associated reinforced concrete footings extending to approximately 1.50 m below existing ground level; demolition and removal of all HCB external envelope and internal partition walls; dismantling of the eucalyptus timber roof structure and removal of corrugated iron sheet (C.I.S.) roof covering; removal of all existing metal doors, windows, frames, fixtures and other associated building elements such as disconnecting electrical & sanitary system. Ls 1.00 0.00
B Ditto but Existing Building labeled "B" in the Architectural drawing legend having a built up dimension of 6,400 mm × 6,100 mm and an average height of 2.80 m, comprising two rooms. Ls 1.00 0.00
C Ditto but Existing Building labeled "C" in the Architectural drawing legend having a built up dimension of 8900 x 3700mm.+ 2400 x 4200mm and an average height of 2.80m comprising three rooms and nine foundation column with footing. Ls 1.00 0.00
6.2 Preparation of the existing dirt road at the interface with the new entrance gate interlocking pavement, including trimming and shaping the existing road edge to a firm and straight profile, removal of loose, soft, or unsuitable soil and debris, thorough cleaning and preparation of the interface, excavation and formation of the required transition area, provision and compaction of suitable subgrade and granular base material, installation of concrete edge restraint and proper connection of the new interlocking pavement to the existing dirt road to form a smooth, stable, and durable transition, all complete as directed by the Engineer. The rate shall include all labor, materials, equipment, excavation, supply and placement of selected fill and base course, watering and compaction, concrete edge restraint, hand tools, protection of adjacent works, trimming and grading, and all incidental works necessary to achieve a proper and durable transition between the existing dirt road and the new interlocking pavement. Ml 4.00 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
AL WALEEB & GUNUB VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.1- Veternary Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 GLAZING USD 0.00
8 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 294.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 75.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 202.00 0.00
1.4 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 23.00 0.00
1.5 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 126.00 0.00
1.6 Ditto as above item 1.5 but around isolated footing. m3 188.00 0.00
1.7 Ditto as above item 1.5 but around masonry foundation wall. m3 12.00 0.00
1.8 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 391.00 0.00
1.9 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 177.00 0.00
1.10 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 217.00 0.00
1.11 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 104.00 0.00
2.1.2 Under masonry foundation wall m2 47.00 0.00
2.1.3 Under grade beam m2 22.00 0.00
2.1.4 Under slab on grade including ramp & outdoor treatment m2 177.00 0.00
2.1.5 Under masonry steps on grade m2 2.00 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 39.00 0.00
2.2.2 In foundation column. m3 4.00 0.00
2.2.3 In grade beams. m3 15.00 0.00
2.2.4 In 15 cm thick ground floor slab including ramps & outdoor tratment. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 177.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 55.00 0.00
2.3.2 To foundation column m2 45.00 0.00
2.3.3 To grade beams & ramps edge m2 155.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 8 mm deformed bar Kg 17.00 0.00
Dia 10 mm deformed bar Kg 53.00 0.00
Dia 12 mm deformed bar Kg 2,117.00 0.00
Dia 14 mm deformed bar Kg 819.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 244.00 0.00
Dia 14 mm deformed bar Kg 170.00 0.00
Dia 16 mm deformed bar Kg 818.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 327.00 0.00
Dia 14 mm deformed bar Kg 331.00 0.00
Dia 16 mm deformed bar Kg 1,020.00 0.00
2.4.4 For floor slab on grade, ramp slab & outdoor tratment slab
Dia 8 mm deformed bar Kg 648.00 0.00
Dia 10 mm deformed bar Kg 173.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 46.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 2.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 8.60 0.00
1.1.2 In top tie beams m3 10.60 0.00
1.1.3 In water tanker slab with beams m3 1.20 0.00
1.1.4 In lintel beams including roof vent windows m3 0.30 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 91.00 0.00
1.2.2 To top tie beams m2 108.00 0.00
1.2.3 To water tank slab with tie beam m2 9.00 0.00
1.2.4 To lintel beams including for roof vent windows m2 3.00 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 182.00 0.00
Dia 16 mm deformed bar Kg 812.00 0.00
1.3.2 For top tie beam
Dia 8 mm deformed bar Kg 270.00 0.00
Dia 14 mm deformed bar Kg 294.00 0.00
Dia 16 mm deformed bar Kg 1,101.00 0.00
1.3.3 For water tanker slab & beam
Dia 8 mm deformed bar Kg 8.00 0.00
Dia 10 mm deformed bar Kg 100.00 0.00
Dia 16 mm deformed bar Kg 28.00 0.00
1.3.4 For water tanker slab & beam
Dia 6 mm deformed bar Kg 8.00 0.00
Dia 12 mm deformed bar Kg 31.00 0.00
Total carried to summary USD 0.00
Walls shall be constructed from class 'B' hollow concrete block (H.C.B.). The blocks shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the blocks shall be in such a way that good key for plasterer is obtained on both side.
2.1 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. m2 349.00 0.00
2.2 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B), the hollow part shall be fully grouted with cement sand mortar and jointed in cement sand mortar mix (1:3) one side left for appropriate finishing and the other side left for to fix sika joint or fiber board.Price shall include cement sand mortar fill inside hollow part of the wall. For X-ray room back wall m2 62.00 0.00
2.3 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) with vertical & horizontal stiffeners bedded and jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. The stiffening methods and application shall be as per the detail structural dwg. Price shall include stiffening concrete and reinforcement.Price shall also include the recessed decorative wall part showing on the right & left side of the building.-for parapet wall m2 48.00 0.00
2.4 Supply and lay 10 cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. m2 6.00 0.00
2.5 Supply, delivery, preparation, and installation of combined brick layers of ( 20 cm + 10 cm),total 30cm thick red burnet brick wall cladding for internal X-ray room walls surface shown on the Ar. Drawing.The construction must comply with radiation protection requirements and shall be proper sealed with sika or fiber board to prevent radiation leakage. The material physical property shall meet the minimal standard to suit the intended purpose. The installation work shall be as per the architectural detail plan and shall be install from bottom up. The contractor shall submit the material sample. Shop drawing showing fixing details. Installation method and mockup sample shall be constructed for the Architect approval.price shall include 10mm thick SIKA or fiber board joint filler (wall substrate) & bonding bar with HCB wall. m2 62.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 235.00 0.00
3.2 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet ridge hip at the roof slope direction changes. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of ridge cap: 80 cm. m.l. 9.00 0.00
3.3 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 50.00 0.00
3.4 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel vally gutter, supported by the side truss members the work shall include all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 450 mm ml 4.50 0.00
3.5 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet copping at the top roof ridge exposed HCB wall. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of copping: 410 mm. m.l. 24.00 0.00
3.6 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 44.00 0.00
3.7 Supply and fix diam 110mm PVC down pipe. Price shall include 900 elbow connection, PVC liner with all the necessary fixing accessories. ml 52.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors and windows all as per the drawing. All doors should have vertical metal grill 25x25x2mm c/c 15cm for burglar proofing and with 0.5mm thick steel louver at top welded to frames and covered with approved mosquito net. All windows should have RHS 10x10x2mm welded to frames and with steel mesh for burglar proofing. All roof vent should have steel mesh welded on the frame. Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint. (glazing measured separately).
TW-1 size 150 x 85 cm no 2.00 0.00
D-1 size 180 x 255 cm-doble leaf door no 1.00 0.00
D-2 size 90 x 255 cm-single leaf door no 6.00 0.00
D-3 size 85 x 255 cm-single leaf door no 2.00 0.00
4,2 Supply, deliver, install, test, and commission factory made steel-framed, lead-lined radiation shielding X-ray door with vision panel, complete with all accessories and certification. The material shall be Steel door frame and solid core door leaf, factory fabricated, Lead lining to door leaf and frame equivalent to 2.0 mm Pb minimum, Vision panel comprising lead glass with equivalent 2.0 mm Pb shielding, Complete set of heavy-duty ironmongery including hinges, lockset, handles, and door closer, Perimeter sealing with radiation-proof gaskets to prevent leakage, Proper installation including lead overlap at joints and shielding continuity and the work shall include Testing, commissioning, and submission of radiation protection compliance certificate. All are as per the detail door and window schedule and engineers approval.
D-1' size 180 x 255 cm-doble leaf door no 1.00 0.00
D-2' size 90 x 255 cm-single leaf door no 1.00 0.00
4,3 Supply, fabrication, and installation of rectangular roof ventilation unit, overall size 80 cm × 40 cm, consisting of fabricated from 38 mm LTZ-profile, 0.16 cm thick frame. Joints to be welded with 4 mm continuous fillet welds, ground smooth and free of sharp edges. Infill woven wire mesh aperture 1.4 mm × 1.4 mm, wire diameter 0.45 mm, securely fixed to frame by recessed groove or retaining clips. Entire vent unit to be cleaned, degreased, and painted with on coat of anti-rust followed by two coats of metal paint. The color shall be approved by the Engineer and the work shall complete as per drawing. no 8.00 0.00
4.4 Supply, fabricate and fix metal guard rail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 120 × 120 × 6 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 1000 mm above finished floor level; two horizontal balustrade rails CHS Ø20 × 2.5 mm welded to vertical RHS posts; top handrail CHS Ø50 × 2.5 mm welded continuously; infill: vertically spaced CHS Ø20 × 2.5 mm at c/c 100 mm between the two horizontal rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 21.00 0.00
4.5 Supply, fabricate and fix metal ramp handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 15.00 0.00
4.6 Supply, fabricate, deliver, install, and paint steel cattle fence (balustrade type) comprising CHS vertical posts, horizontal rails, and base plates, fixed to concrete floor, complete in all respects. The work shall be Steel fence consisting of Ø100 × 5 mm CHS vertical posts (900 mm height) fixed to concrete using 170 × 170 × 6 mm base plates, spaced at maximum 1000 mm centers, with 4 No. horizontal Ø80 × 2.5 mm CHS rails welded to posts, including all welding, anchoring bolts, alignment, and accessories, finished with anti-rust primer and final metal paint (minimum two coats each), complete as per drawings and Engineer’s approval. ml 14.00 0.00
4.7 Supply and fix elevated water tanker seat metal guard rail all according to size and shape specified on the drawing . Price shall include connection plates, bolt and one coat of primer & two coats of synthetic enamel paint. ml 8.00 0.00
4.8 Ditto as above item and supply, fabricate, deliver,instal and paint steel structure ladder as shown the At. detail drawing. ml 8.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect steel structures using RHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel Structure Column
Steel structure columns are vertical primary load-bearing members, transferring axial loads (and occasionally bending) from trusses to foundations. Since columns are in direct contact with water during cleaning, apply bituminous damp-proof paint at the column base up to a height of 300 mm (30 cm) to prevent corrosion and moisture penetration. price shall damproof paint and stiffening plates as shown in the drawing. for measurment net RHS post will be considered execluding stiffening plates.
A.1 Steel structure column RHS sections of 100 × 100 × 4mm for veranda post. kg 218.00 0.00
B. Steel Structure Column Beam
The beam shall be welded column to column just below the top plate level where truss and column connected. At the end of the beam where there is no steel column. it connected with the building it will be fixed with plate at the concrete column/tie beam
B.1 RHS 80 x 60 x 4mm beam for veranda kg 245.00 0.00
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards. Price shall include gusset plat, connection plate when truss members connect and bolts other than anchor/J-bolt bolts.
C.1 RHS 80 x 80 x 4mm upper & lower truss member for T1, T1' & T2-for T-1' includes vertical member Kg 1,701.00 0.00
C.2 RHS 60 x 60 x 3mm upper & lower truss member for T3, T4 & T5 Kg 434.00 0.00
C.3 RHS 60 x 60 x 4mm diagonal & vertical truss member for T1 & T2 Kg 685.00 0.00
C.4 RHS 50 x 50 x 4mm diagonal & vertical truss member for T3, T4 & T5 Kg 149.00 0.00
D. RHS Purlins 0.00
D.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 100 x 100 x 3mm L= 60mm angle iron. Price include angle iron. Kg 2,145.00 0.00
E. RHS Solar PV Support System 0.00
Supply, fabricate, deliver and install solar panel steel support structure complete with all necessary connection components. The work shall include provision of gusset plates, bolts, nuts, washers, and all fixing accessories required for proper assembly and stability of the structure.The rate shall include surface preparation and application of approved anti-corrosion primer and finishing paint. It shall also include proper sealing and waterproofing treatment where steel members penetrate the roof covering, ensuring no water leakage. All works shall be executed in accordance with approved shop drawings, specifications, and engineer’s instructions.
E.1 RHS 80 x 80 x 4mm steell structure frame member Kg 2,072.00 0.00
E.2 RHS 40 x 40 x 4mm purlin Kg 536.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate for verenda post-size 250 x 250 x 6mm with 4 dia 22 slotted holes. The plated is welded to the RHS post (fillet weld of 3mm throat thickness) and connected to the other plate fixed on concrete column. No 12.00 0.00
A.2 Base plate size 250 x 200 x 6mm with 4 dia 18 slotted holes for truss & ring beam. The plate is welded to the truss (fillet weld of 3mm throat thickness) and connected to ring beam. No 86.00 0.00
A.3 Top plate size 150 x 150 x 8mm for veranda post and RHS beam connection with bolt & nut. No 12.00 0.00
B Bolt with nut
B.1 Base plate/Anchor bolt dia. 16 Length 250mm for truss beam connection and to be weld to ring beam steel reinforcement No 172.00 0.00
B.2 Base plate/Anchor bolt dia. 20 Length 450mm for veranda post No 24.00 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of gypsum finish to internal HCB wall surfaces. m2 535.00 0.00
6.2 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of gypsum finish to internal exposed beam and column surfaces. m2 69.00 0.00
6.3 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive rendering finish to externall HCB wall surfaces. m2 205.00 0.00
6.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final rendering finish to external exposed beam and column surfaces. m2 112.00 0.00
6.5 Prepare the surface and apply final a 3 mm to 5 mm thick final skim coat using a 1:3 cement-to-fine-sand mortar mix. Fine sand must be sieved through a 1.18 mm mesh. The surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks to internal wall, beam & column surfaces. m2 604.00 0.00
6.6 Prepare the surface and apply final apply 15mm thick cement and sand rendering (1:3 mix) for external wall surface. Price includes surface preparation, hacking of concrete surfaces, wire mesh for joints, curing for 7 days. The rendering pattern shall be as per the Architect approval. m2 317.00 0.00
6.7 Prepare the surface, supply and construct 2 cm thick x 25 cm wide polished marble threshold for doors bedded on cement sand mortar 1:3. Price include 30mm thick cement sand mortar backing and white cement grouting. All are as per the detail Ar. Dwg. ml 10.00 0.00
6.8 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 59.00 0.00
6.9 Prepare the surface, supply and fix nominal thickness of 0.85 cm approved standard 60 x 60 cm non-slippery ceramic floor tiles bedded in an average 4.15 cm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 12.00 0.00
6.10 Prepare the surface and apply epoxy resin coating flooring as shown in the drawing- the epoxy flooring shall be suitable type for veternary clinic:- Epoxy floor, shall be applied on the concrete floor or 4.6 cm thick cement sand screed flooring using OPC cement and Rheomix 141 strengthening additive in order to achieve the required bedding strength for animal hoof. The application of the screed shall be leveled and finished with a fine texture screening while the concrete is fresh and it is preferable to hold the proper application of epoxy floor finish with out any additional leveling. screed to the base floor shall be done with proper slope as instructed by the engineer and shall be done as per the advice and follow up of the epoxy supplier in order to assure the bonding between the concrete slab and screed. The contractor should use bonding chemical agent primer that shall be approved by the Engineer. Price shall include screed, Rheomix 141 strengthening additive and epoxy floor finish. m² 38.00 0.00 4800 0 0 4800 #REF! #REF! #REF! #REF! #REF! #REF!
6.11 Prepare the surface and construct belt & brace flooring as shown the detail Ar. Detail drawing. The work shall be 1 x 2 cm slip resistance diamond grooved finish with non metalic dry shake hardner. All are as per the detail drawing, manufacturere instruction and Engineer approval. m² 93.00 0.00
6.12 10cm high 1cm thick chamfered ceramic skirting of matching color to floor tiles. ml 106.00 0.00
6.13 Supply and fix 30 x 60 x 0.85 cm ceramic wall cladding, of matching color to floor, stuck to wall with cement sand mortar 1:3 backing and grouting with white cement wash. Price shall include rod anchors to backing. Size, color and pattern according to architect's drawings. m2 106.00 0.00
6.14 Supply and fix granite stair tread bedded on cement mortar 1:3 price include mortar bed, nosing and chamfering. Color and pattern shall be approved by the Architect.
a) For entrance step-tread
- Tread size: (33 x 3 cm) ml 8.00 0.00
6.15 Ditto as above but riser.
a) For entrance step-rise
- riser size: (13.4 x 2 cm) ml 8.00 0.00
6.16 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick marble window sill. Price shall include cement sand mortar bed and cement grouting. ml 12.00 0.00
6.17 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick marble short wall copping. Price shall include cement sand mortar bed and cement grouting. ml 12.00 0.00
6.18 Supply and fix chamfered, bullnose and water dripped 25 x 3cm thick marble edge trim for veranda edge. Price shall include cement sand mortar bed and cement grouting. ml 21.00 0.00
6.19 Supply and fix approved quality 0.8cm thick chip wood ceiling as per the detail drawing and engineers approval. The batten fixing method with steel truss shall be L-shaped or U-shaped steel brackets welded/bolted to the steel truss members. Battens are then nailed or screwed to the brackets. Price shall include 4 x 5 cm suspensions wooden battens with c/c spacing of 600mm both ways, middle and corner list, nails and all the necessary fixing accessories. m2 105.00 0.00
6.20 10 cm thick Concrete pavement around the building bedded on 10 cm thick red ash or fine aggregate and 20cm thick compacted granular materials. The work shall be mixing, placing, compacting, curing, and finishing of concrete with trowel finish while fresh. Price shall include red ash bed, selected fill and trowel finishing work. m2 90.00 0.00
Total Carried to summary USD 0.00
7.1 Supply and fix 0.5cm thick clear glass. Price shall include all the necessary fixing accessories. m2 15.00 0.00
7.2 Supply and fix 0.5cm thick figured glass. Price shall include all the necessary fixing accessories. m2 6.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
8.1 Apply three coats of plastic emulsion paint to internally gypsum plastered wall surfaces. m2 604.00 0.00
8.3 Ditto as item 8.1, but to chip wood ceiling. m2 105.00 0.00
8.3 Apply final acrylic emulsion paint to external rendered wall surface, exposed R.C columns and beams. m2 317.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
AL WALEEB & GUNUB VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.2- Veternary Building-Electrical Installation
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
9 ELECTRICAL WORKS
9.1 uPVC Pipes and Ducts
9.1.1 50mm diameter uPVC m 10.00 0.00
9.2 Earth Network (Grounding System)
9.2.1 Grounding pit 500x500x500mm with top cover inscribed "Grounding pit" as per the detail drawing No 1.00 0.00
9.2.2 Under ground termination network with bare copper cnductor of 1x70sq.mm ml 100.05 0.00
9.2.3 Insulated ground connecting copper cable of 1x70sq.mm ml 30.00 0.00
9.2.4 Earthing electrode diameter 20mm and length 3000mm
Note:If the earth resistence is more than 10 ohms
add additional electrode spaced at length of
the electrode (spaced at a minimum of 5m appart) No 5.00 0.00
9.3 DISTRIBUTION BOARDS
9.3.1 Factory assembled and tested surface-mounted main distribution Board, MDB in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting:
1pc main RCBO of 50A, 3ph , Icu=16KA, 30mA.
1pcs MCB of 32A, 3ph , Icu=10KA
2pcs MCB of 20A, 1ph , Icu=10KA
7pcs MCB of 16A, 1ph , Icu=10KA, coupled with RCD of 30mA. 0.00
8pcs MCB of 16A, 1ph , Icu=10KA
4pcs MCB of 10A, 1ph , Icu=10KA
2pcs MCB of 16A, 1ph (spare) Icu=10KA
1Pc of surge arrestor of 40KA
3 pcs current meters of 50/5A with 6A fuse
1 pc Volt meter of 500V with selector switch and 6A fuse
1 pc frequency meter
with 25% reserve space and busbar of 63A/3ph. No 1.00 0.00
9.4. Feeder Cables and PVC pipes
PVC Sheathed PVC Insulated power cable type NYY 0.6/1KV or equivalent to be drawn inside riser shaft or PVC conduit (measured elsewhere, tentative) and of:-
Cable sizes include: 0.00
9.4.2 5x10 mm2 From Inverter to MDB m 5.00 0.00
9.5. Light & Switch Points 0.00
9.5.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 46.00 0.00
9.6. Light Fittings and Lamps 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved.
9.6.L1 LED Panel Light: 600x600mm, 22.5W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 6.00 0.00
9.6.L2 LED Panel Light: 300x1200mm, 27W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 8.00 0.00
9.6.L2E LED Panel Light: 300x1200mm, 27W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free, & ~1000 lumens (emergency), 4000K, 90 minute operation, No 3.00 0.00
9.6.L3 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 11.00 0.00
9.6.L4 LED Batten Light:L600mm, CRI > 80, ceiling-mounted, polycarbonate, IP44, flicker-free. No 2.00 0.00
9.6.L5 LED Slim Downlight: 10W, 1100 lumens, 4000K, CRI > 80, polycarbonate, IP44, 220VAC, driver included, No 8.00 0.00
9.6.L6 Mini LED Wall Pack for Toilet Mirror, 10W, 1000 lumens,4000K, CRI > 80, wall-mounted, polycarbonate, IP65 No 3.00 0.00
9.6.(E) Non-maintained LED emergency light (only activates during power failure). Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). Warranty: 3 years (components), 5 years (battery). No 4.00 0.00
9.6(ODL) Over door light bulk head to indicate occupancy of the xray room No 1.00 0.00
9.6. Socket Points
9.6. 10-16A/1P flush mounted/recessed socket outlets point fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 20.00 0.00
9.9.2 Dito but for Double Outlet No 10.00 0.00
9.7 Power outlet points.
9.7.1. 16A/1P power outlets point for exaust fan and booster pump fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 8.00 0.00
9.7.2 20A/1P power outlets point for split AC fed through PVC insulated conductors of 3x4mm² inside PVC conduits of 19mm inner diameter, including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type-approved. No 2.00 0.00
9.7.3. 32A/3P power outlets point for X-Ray Machine fed through PVC insulated conductors of 5x6 mm² inside PVC conduits of 32mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 1.00 0.00
9.7. Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard.
9.7. Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete.
9.7.1 Single Pole 1-Way Switch No 6.00 0.00
9.7.2 Double pole Switch No 6.00 0.00
9.7.3 Two Way Switch No 6.00 0.00
9.7.4 Two Way Switch Weather proof for outdoor installation No 2.00 0.00
9.7.4 Intermidiate Switch Weather proof for outdoor installation No 1.00 0.00
9.8. Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00
9.8.1 16A ,1ph ,220V 2p+e socket out let No 20.00 0.00
9.8.2 Dito but Double (Twin) Outlet No 10.00 0.00
9.9 Lightning Arrester System
(Eritech or Equivalent)
Shall include all metalic structures in the network with appropriate welding (ventpipes,ducts ,GIS roof & structures, solar PV panels, e.t.c)
9.9.1 Early Streamer Emmision(ESE) Protector SI 25 with mounting mast of H=3.0m and all necessary connecting acessories. No 1.00 0.00
9.9.2 25x3mm copper tape with all necessary roof connecting accessories m 90.00 0.00
9.9.3 25 x 3mm insulated copper tape with vertical supportings every 1m to the wall & all the necessary accessories coordinate the routing of down conductors with the building external skin and architectural features. ml 40.00 0.00
9.9.4 Lightening Event counter to be installed on the down conductor to count number of lightening strikes. No 2.00 0.00
9.9.5 Test point (junction box) with all necessary connection acessories to connect the down conduction with the earthing bare copper wire. at least 1.5m above floor finish. No 2.00 0.00
9.9.6 Prefabricated Crowsfeet 25x3mm tinned coper tape. In complienc with IEC-EN 62561-2, with L1=1000mm and L2= 3000mm No 2.00 0.00
9.9.7 50 x 50 x 50 cm test pit with top cover inscribed "Test pit" as per the detail drawing No 5.00 0.00
9.9.8 1 x 70 sq.mm bare copper wire. ml 10.00 0.00
9.9.9 Diameter 20mm & 3000mm long copper rod. No 2.00 0.00
9.10 DATA\ Telecome System
Tel/Data according to manufacturer’s and utility supplier’s requirements, supplied, installed, connected color coded including tags and tested, complete, all as specified and / or as shown on the drawings.
Structured Cabling
Horizontal CAT6A Cabling
9.10.2 Tel/Data and Data/Data points fed through 2x(twisted pair category 6A UTP cable) inside FRLS PVC conduits of 20mm diameter and thickness not less than 1.5mm with conduits accessories (coupling, junction boxes) for tele/Data outlet socket. No 11.00 0.00
9.10.3 Cat 6A 24 port Patch Panel RJ 45 contact No 2.00 0.00
9.10.4 Cat 6A RJ 45 Patch Cord 0.5m, from switch to pantch panels No 48.00 0.00
9.10.5 Cat 6A RJ 45 Patch Cord 3m, from outlets to workstation computers. No 11.00 0.00
Equipment Racking
9.10.6 Wall Mount metallic rack of 15U pivoting cabinet swing 19" steel enclosure with transparent and lockable door, Built-in PDUs (8-10 Outlets, Grounded) and cooling fans. No 1.00 0.00
9.10.7 1U Horizontal Cable Management Bars, 5 Vertical Plastic Hoops with Cover No 3.00 0.00
Information Outlets: Data &Voice
Extra Over Data Socket Outlets with Detachable Frames & Corresponding Box
9.10.8 2 x RJ45 8 Contact CAT6a Socket Outlets No 11.00 0.00
Active components Type CISCO or approved equivalent.
9.10.10 48-port Gigabit Data +2x10G uplink Switch . No 1.00 0.00
9.10.15 Hybrid PBX with 24Analog, with 4 trunk, Extension including Operator Phone No 1.00 0.00
9.10.16 Cat 6A RJ 11 Patch Cord 1m No 24.00 0.00
9.11 FIRE ALARM SYSTEM
9.11.1 Convensional Fire alarm Control Panel, 2 zones Complete with power supply & battery backup. No 1.00 0.00
9.11.2 smoke detector; with Flash Scan and Detector Base, Complete No 10.00 0.00
9.11.4 Fire alarm sounder strobe (RED) No 2.00 0.00
9.11.5 Surface mounted manual break glass push button including back box No 2.00 0.00
9.11.6 Flush Mounted Fire Alarm Points fed in 2 x 1.5sq. mm Fire Alarm cable (SLC-detectors) inside FRLS PVC conduits of 16mm diameter and thickness not less than 1.5mm with conduits accessories (coupling, junction boxes) No 14.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
AL WALEEB & GUNUB VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.3- Veternary Building-Sanitary Installation
CLINIC BLOCK SANITARY WORKS
1.1 SANITARY EQUIPMENET ( FIXTURES ) USD 0.00
1.2 Water Supply Pipes and Valves USD 0.00
1.3 Waste Pipes and Accessories USD 0.00
1.4 HVAC System USD 0.00
1.5 Fire Fighting System USD 0.00
Total Veternary Clinic Building-Sanitary Installation USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 SANITARY EQUIPMENET ( FIXTURES )
All fixtures which are specified below is subject to the owner's / consultant's approval, based on samples, catalogues and brochures presented by the contractor. Unit price shall include all the necessary fixing brackets or hooks and all assistance civil works such as chiseling of walls, floors, beams and etc.
1.1.1 HAND WASH BASIN (ORDINARY)
Supply and fix R.A.K. or Equivalent, hand wash basins made of white glazed vitreious china with REMER/JAQUAR or Equivalent chrome plated cold water tap, pedastal stand ,complete with stop & arrest valves on water inlet pipe. mixing battery plug, chrome plated chain holder, P-smell trap with connection pipe, fittings, all other necessary etc.complete in all respects. Flexible hose to be REMER or Equivalent and should be capable of resisting pressure of 4 bar. P-smell trap should be brass chrome plated with 50mm height of water seal and trap. № 1.00 0.00
a) Size :- length X width (1000mm x 435mm)
1.1.2 Ditto No 1.1.1 but for animal health clinic medical laboratory and surgical purpose each with two bowl. № 2.00 0.00
1.1.3 Ditto No 1.1.1 but for cleaner room № 1.00 0.00
WATER CLOSET (ORDINARY)
1.1.4 Supply and fix wash-down action toilet squatting pans made of white vitreous china, complete with high-level flush cistern, vertical flush pipe connecting the cistern to the squatting pan, and all necessary accessories. The price shall include stop and arrest valves before water inlet; cistern of vitreous china with a capacity of 7 to 9 liters and maximum filling time of 2 minutes, complete with heavy-duty float valve suitable for water pressure up to 4 bar; chrome-plated steel flush valve; heavy-duty flexible pipes rated for a working pressure of 4 bar; and vertical flush pipe of durable corrosion-resistant material (e.g., galvanized steel, stainless steel, or UPVC) connecting the cistern outlet to the pan inlet, complete with necessary bends, brackets, and wall fixings. Where specified, a hygienic flush/bidet connection shall be provided, comprising a flexible hose, handheld spray nozzle, wall bracket, and appropriate isolating valve. № 2.00 0.00
SANITARY WARES FOR PERSONS WITH DISABILITY (PWD)
1.1.5 Supply and install complete set of sanitary wares for physically challenged toilet room fixtures and accessories including: *Vitreous china wc seat with brass or stainless steel hingedheavy duty plastic cover*Vitreous china hand wash basin with lever action faucet with mixer, brass or chrome smell traps and accessories * 6 liters capacity vitreous china cistern with long lever action flushing arm * 5 pieces of stainless steel grab rails (600x35mm) with slip resistant grip and concealed fixings* Blue Folding rails 850mm,760x305mm flush bends,cloth hooks * Stainless steel lever action hinged drop down rail * Color contrasted padded backrest * Automatic hand dryer * Soap Dispenser * Paper Towel Dispenser * Toilet Tissue Dispenser * Alarm Rest Button * Stainless steel Mirror 1000*400mm & all the necessary material to make the toilet functional. The sanitary ware set shall satisfy BS 8300-2 and BS EN 12182. № 1.00 0.00
1.1.6 WET ROOM ACCESSORIES
1.1.6.1 Supply and fix soap holder in white vitreous china of size 150 x 150 mm. Complete with the necessary fixing and other accessories. № 3.00 0.00
1.1.6.2 Supply and fix toilet paper holder from chrome plated brass wall flanged roll with chrome plated fastening screws and other accessories. № 2.00 0.00
1.1.6.3 Supply and fix crystal glass mirrors for toilets hand wash basins for changing rooms and private rooms with copper back protection, including chrome plated brass mirror clips with chrome plated screws and all the necessaary accessories. a) size 500 X 400 mm № 3.00 0.00
1.1.6.4 Supply, fix, test and commission floor drains made of polished steel, complete with P-smell trap /minimum seal depth 75mm/ and all other necessary fittings and accessories. № 4.00 0.00
Total carried to summary USD 0.00
1.2 Water Supply Pipes and Valves
Domestic water pipes shall be in PPR- PN 4 & be fixed to walls, beams or etc… with metal/ compatible straps. Unit price shall include all assistance civil works and necessary fittings such T, bends, Y, reducers Unions and other necessary valves shall be fixed properly as per the manufacturer's instruction and according to where shown on the drawing. Hot water supply shall be properly insulated and external PPR pipe has to be coated All water pipes shall be tested two times the working pressure or 100 meters head, which ever is greater at the expense of the contractor.
1.2.1 Supply and install PPR PN-4 pipes to internal domestic water distribution system pipes as where shown on the drawing. And external pipes shall be coated Complete with all the necessary fittings and accessories. The pipe shall be coated when applied on exposed surfaces.
1.2.2 Supply and fix chrome service valves of approved standard before hand wash basins, water closets and other fixtures. Complete with unions, elastic water proofing, hand wheels of normal quality and with all other necessary accessories.
1.2.3 Ditto to item number 1.2.2 approved quality bronze gate valves on internal branch water pipes and pipe inlet to building of the following size and as where shown on the drawing.
1.2.4 Supply, Installation, Testing, and Commissioning of Wall/Window Mounted Exhaust Fan: Fan Unit: The exhaust fan shall be a wall or window mounted type, specifically designed for bathroom/ toilet ventilation. Performance: Airflow Capacity: Minimum free air delivery of 200 cubic meters per hour (m³/hr) at 25 Pa static pressure. Sound Level: The maximum sound power level (Lw) shall not exceed 35 dB(A) when measured in accordance with relevant standards. Components & Accessories: The unit shall be complete with all necessary accessories for effective operation, including but not limited to: Multi-speed controller. Integral back-draft shutter. External rain guard/weather louvre. Grille or front cover. All required fixings, gaskets, and seals. Scope of Work: The unit rate shall be inclusive of, but not limited to, the following activities: Supply of the exhaust fan and all specified accessories. Necessary civil works to create or make good the opening, including sealing and making the installation weatherproof. Electrical wiring from the nearest power source, including a dedicated isolation switch, as per electrical codes. Final installation, testing, and commissioning of the system to ensure optimal performance. № 2.00 0.00
Total carried to summary USD 0.00
1.3 Waste & vent Pipes and Accessories
All domestic waste water pipe lines shall be uPVC (PN10) pipes and shall be provided with a minimum slope of 2% towards the outlet. All uPVC pipes and necessary fittings shall be standard quality and be free from damage during storage, construction and etc. Unit price shall include all the necessary assistance civil works, such as excavation cartaway, fixing or hanging to walls, beams or slabs.etc., necessary fittings such as bends, Y, T, etc.
1.3.1 Supply and lay internal uPVC waste according to where shown on the drawings. Complete with all the necessary fittings.
Dia. 50 mm ml 4.00 0.00
1.3.2 Ditto No 1.3.1 for vent pipes with appropriate end cap
1.3.3 FCO(FLOOR CLEAN OUT)
Supply and fix approved quality screw type under slab Clean Out on waste water as where shown on the drawing. Price shall include all the necessary
1.3.4 Animal waste open dith with galvanized steel grate for cattles out door treatment area ml 4.00 0.00
DITCH-: SIZE[mmXmm] = 300 X 300
1.3.5 Dito 1.3.4 but for animal health clinic cattles recovery room treatment area ml 4.00 0.00
DITCH-: SIZE[mmXmm] = 300 X 300
1.3.6 Dito 1.3.4 but for animal health clinic treatment room & X ray rooms.
DITCH-: SIZE[mmXmm] = 300 X 300 ml 8.00 0.00
Total carried to summary USD 0.00
1.4 HVAC System
Supply, installation, testing, and commissioning of HVAC and mechanical ventilation systems for four (4) distinct room types considering high ambient operation temperature of 52 ºC.The items shall be Anti-corrosion treatment for coastal sites, refrigerant pre-charged for up to 15m piping length, Service valves with Schrader ports. The scope of the work include power cabling work from power point to HVAC equipment.
1.4.1 Supply, install, test and commission a complete high ambient split-type air conditioning unit of 1.5 TR (5.3 kW cooling capacity, equivalent to 18,000 BTU/h). The unit shall be inverter type, utilizing R32 or R410A refrigerant (R22 is strictly prohibited), and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 1.3 kW. The system is designed for cooling only and shall be factory-rated for continuous operation in high ambient temperatures up to 52°C. The system shall consist of one (1) wall-mounted indoor evaporator unit and one (1) outdoor condensing unit, complete with all interconnecting refrigerant piping, control wiring, condensate drain line, remote control handset, and all necessary accessories for a complete and functional installation. Indoor Unit (Evaporator): The indoor unit shall be constructed of UV-stabilized ABS plastic with a white finish. It shall include automatic horizontal and vertical swing louvers, a washable antimicrobial pre-filter, and a cross-flow fan designed for silent operation.
Outdoor Unit (Condenser): The outdoor unit shall be an inverter-driven condensing unit with digital inverter (variable speed) compressor, specifically rated for high ambient operation. The unit shall include corrosion-resistant condenser coil and fan motor. Refrigerant Piping: Interconnecting refrigerant piping shall be provided for a distance of not less than 15 meters (49 feet) between the indoor and outdoor units. The piping shall consist of seamless copper tubing, with liquid line of 6.35 mm (1/4 inch) OD and suction line of 12.7 mm (1/2 inch) OD. The suction line shall be insulated with 13 mm (0.5 inch) thick closed-cell elastomeric foam. Control and Operation: The system shall include a wireless infrared remote control handset enabling full functionality. Features shall include LED display with temperature readout, sleep mode, turbo cooling mode, on/off timer (1-24 hours), auto restart after power failure, and self-diagnostic fault code display. Electrical Characteristics: The unit shall have rated load amps (RLA) of approximately 6.0 A, minimum circuit ampacity (MCA) of 8.0 A, and maximum overcurrent protection (MOP) of 15 A. All electrical components shall be rated for 230V / 50Hz supply. Condensate Drain: The unit shall include a condensate drain line of 25 mm (1 inch) nominal diameter PVC pipe, properly trapped and sloped at minimum 1:100 gradient to designated drainage point. Compliance: The equipment shall satisfy conformity with European health and safety standards (IEC 60335-2-40) or equivalent international certification acceptable in Sudan. The Contractor shall submit manufacturer cut sheets and conformity certificates for engineer's approval prior to procurement. Acceptable Brands: Gree, Midea, LG, Carrier, Daikin, or approved equivalent. № 1.00 0.00
1.4.2 Supply, install, test and commission a complete wall-mounted, high ambient exhaust fan for the X-Ray room, designed to provide mechanical extraction of air while maintaining negative pressure and preventing radiation leakage. The fan shall be mounted directly on the exterior wall face over a specially constructed shielded labyrinth penetration through the brick wall. No external ductwork shall be required. The fan shall be centrifugal or axial type,The fan shall deliver a minimum airflow of 150 m³/h (approximately 90 CFM) at static pressure of 100 Pa (10 mmH₂O or 0.4 inches w.g.) rated for continuous operation in high ambient temperatures, and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 0.08 kW (80 Watts) . The system is designed for exhaust-only ventilation (no supply fan) and shall be installed in conjunction with a passive labyrinth intake for fresh air. The system shall consist of one (1) wall-mounted exhaust fan (maximum power: 0.08 kW), one (1) shielded labyrinth penetration constructed through the brick wall, one (1) interior exhaust grille (high-level mounted), one (1) exterior weatherproof louver, one (1) backdraft damper, and all necessary accessories for a complete and functional installation. No ductwork (rigid or flexible) is required between the fan and the room. The Contractor shall construct a shielded labyrinth penetration of "S" or "Z" configuration (offset path) through the 450 mm thick wall. No straight line of sight shall exist from the interior of the X-Ray room to the exterior fan housing or to the outside environment. № 1.00 0.00
1.4.3 Ditto No 1.4.1 but for laboratory room and with cooling capacity of 2.0 TR (7.0 kW cooling capacity, equivalent to 24,000 BTU/h) and maximum power input of 1.80 kW (1,800 Watts) . № 1.00 0.00
1.4.4 Supply, install, test and commission a wall-mounted fresh air supply fan for the Laboratory Room, designed to provide forced filtered(with MERV 8 filter (replaceable type) to filter incoming outdoor air) outdoor air to meet the ventilation requirement. The fan shall be mounted directly on an exterior wall or window, requiring no ductwork. The fan shall be rated for continuous operation in high ambient temperatures up to 52°C, and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 0.1 kW (100 Watts) . Performance Characteristics: The fan shall deliver a minimum airflow of 200 m³/h (approximately 120 CFM) at static pressure of 50 Pa (5 mmH₂O or 0.2 inches w.g.) – lower static pressure is acceptable because no ductwork is attached. Construction: The fan shall be of wall-mounted type, suitable for through-wall or through-window installation. The fan casing shall be constructed of UV-stabilized ABS or galvanized steel with corrosion-resistant coating. The motor shall be sealed type, IP44 minimum (or IP54 for exterior exposure). The fan shall include: Integral backdraft damper (gravity-operated) to prevent reverse airflow when fan is off, Integral insect screen on exterior side,Exterior weatherproof louver (may be integral or separate),Interior grille (may be integral or separate) with manual damper for airflow adjustment, Mounting: The fan shall be mounted on a wall or window frame on one side of the room (e.g., the 4.8 m wall). A circular or rectangular hole shall be cut through the wall or window frame to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. The fan shall be installed level and plumb. № 1.00 0.00
1.4.5 Ditto No 1.4.4 but for exhaust air system designed to maintain negative pressure and remove airborne contaminants from laboratory room and shall deliver a minimum airflow of 500 m³/h (approximately 300 CFM) at static pressure of 50 Pa (5 mmH₂O or 0.2 inches w.g.) – lower static pressure is acceptable because no ductwork is attached. The fan shall consume maximum 0.1 kW (100 W) . Low-Level Mounting: For effective removal of heavier-than-air contaminants (e.g., chemical vapors, dust), the exhaust fan should be mounted low on the wall, approximately 200 mm to 500 mm above finished floor level. The Contractor shall confirm the mounting height with the Engineer prior to installation. Mounting: The fan shall be mounted on the wall opposite the supply fan (e.g., on the opposite 4.8 m wall). A circular or rectangular hole shall be cut through the wall to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. The fan shall be installed level and plumb. № 1.00 0.00
1.4.6 Ditto No 1.4.4 but for tretment room and shall deliver a minimum airflow of 900 m³/h (approximately 530 CFM) at static pressure of 50 Pa (5 mmH₂O), while consuming maximum 0.37 kW (370 W) . № 1.00 0.00
1.4.7 Ditto No 1.4.5 but for tretment room and shall deliver a minimum airflow of 150 m³/h (approximately 90 CFM) at static pressure of 50 Pa (5 mmH₂O), while consuming maximum 0.08 kW (80 W . The fan shall be mounted on the wall opposite the supply fan to achieve cross-ventilation. The fan may be mounted at mid-height (1.5 m AFF) or high level. A circular or rectangular hole shall be cut through the wall to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. № 1.00 0.00
1.4.8 Ditto No 1.4.5 but for a complete exhaust-only ventilation system for the Animal Clinic Isolation Room, designed to deliver a minimum airflow of 1,000 m³/h (approximately 590 CFM) at static pressure of 150 Pa (15 mmH₂O), while consuming maximum 0.2 kW (200 W) maintain negative pressure for containment of airborne pathogens.The fan shall be mounted directly on an exterior wall, requiring no ductwork (or minimal ductwork for distribution). The fan shall be rated for continuous 24/7 operation, and shall operate on a single-phase 230V / 50Hz power supply. № 1.00 0.00
1.4.9 Ditto No 1.4.1 but for electric/battery room and with cooling capacity of 0.85 TR (2.5 kW cooling capacity, equivalent to 8530.36 BTU/h) and maximum power input of 0.60 kW (600 Watts) . № 1.00 0.00
1.4.10 Ditto No 1.4.5 but for a complete exhaust-only ventilation system for the toilet cubicles, designed to deliver a maximum airflow of 300 m³/h (approximately 176.57 CFM) at static pressure of 60 Pa (0.45 mmH₂O), while consuming maximum 0.06 kW (60 W) maintain negative pressure for containment of airborne pathogens.The fan shall be mounted directly on an exterior wall, requiring no ductwork (or minimal ductwork for distribution). The fan shall be rated for continuous 24/7 operation, and shall operate on a single-phase 230V / 50Hz power supply. № 2.00 0.00
1.4.11 Ditto No 1.4.10 but for janitory room. № 1.00 0.00
Total carried to summary USD 0.00
1.50 FIR FIGHTING SYSTEM
4.10 Supply and fix 5kg of ABC type fire extinguisher with metal protection cover as per shown location on the drawing. № 6.00 0.00
4.20 Ditto ( 4.1) but CO2 type for solar electrical control room № 1.00 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
AL WALEEB & GUNUB VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.3 Solar PV Installation
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
Supply, install, test, and commission a roof-mounted solar photovoltaic (PV) system with a total installed capacity of 22.78kWp, complete with battery storage and a three-phase inverter, designed for reliable off-grid operation. The system shall be engineered for a minimum service life of 20 years, and shall include all required components, accessories, protections, and ancillary works necessary to deliver a fully functional and complete installation, consisting of the following:
1 PV Modules Type Longi solar or approved Equivalent
Monocrystalline bifacial module, 670 Wp, efficiency ≈24.8%, Voc ≈54.6 V, Vmpp ≈45.27 V, IEC 61215/61730 certified. 2 rows × 16 modules roof-mounted; Tier-1 quality and high reliability. Type Longi solar or approved Equivalent. No 34.00 0.00
3 Hybrid Inverter Type Huawei or approved equivalent
3-phase hybrid inverter, 25kW output, 2 MPPT (200–1000 V DC), efficiency ≥ 98.4 %. Integrated battery interface & smart monitoring. No 1.00 0.00
4 Battery System, Type Huawei or approved equivalent
Lithium Iron Phosphate (LFP) stack 15 kWh nominal (14.25kWh usable), 600 V DC nominal range (600–980 V) for 3Ph system. Safe chemistry >4000 cycles. stacks 2.00 0.00
5 Battery Control Modules (PCM)
Power Control Module per stack, manages communication and charge/discharge interface to the hybrid inverter. pcs 2.00 0.00
6 DC protection panel
IP65, 1000V DC protection panel (PV Rated) with busbar ≥ array Isc , 63A, earthing terminal, and all associated accessories consisting of:
2pc DC-rated MCB of 25A
2pc DC-rated String isolator of 32A
1pc, PV rated DC SPD, Type II, In ≥ 20KA pcs 1.00 0.00
All components shall be rated for a minimum of 1000 VDC and suitable for photovoltaic applications. pcs 1.00 0.00
7 DC & AC Cabling
Cu XLPE cables rated 1 kV DC/AC; Includes MC4 connectors, lugs, glands, and labels. ≤ 1.5 % V-drop. 0.00
7.1 1x 4mm2 1kv/DC cables, for PV string connection. ml 60.00
7.2 2x 6mm2 1kv/DC cables, PV string, and from DC protection Panel to Hybrid inverter. ml 10.00 0.00
7.3 2x 10mm2 1kv/DC cables from Hybrid inverter to Battery stacks. ml 10.00 0.00
7.4 5x 10mm2 0.6/1kv AC cables from Hybrid inverter(HIN) to MDB ml 10.00 0.00
8 Monitoring & Communication
Smart Dongle / Gateway (Wi-Fi or Ethernet). Real-time data, alarms, remote monitoring and system analytics. Type Huawei FusionSolar or approved equivalent. set 1.00 0.00
9 Earthing & Lightning Protection
The Solar PV strings shall be bonded to the Early Streamer Emission (ESE) lightning protection roof network using 25 × 3 mm copper tape to ensure effective lightning protection. The PV array structure shall also be bonded to the main earthing network through 70 mm² copper earthing cables, bonding bars, and lightning down conductors. The overall earthing system shall achieve an earth resistance not exceeding 5 Ω. LS 1.00 0.00
10 Installation, Testing & Commissioning
Complete installation of PV array, battery, inverter, wiring, earthing. Includes polarity, insulation, I-V curve, and BMS integration tests, training & handover. LS 1.00 0.00
11 Contingency / Miscellaneous
Spare connectors, cable glands, fasteners, transport, minor site materials. Covers unforeseen adjustments during installation. LS 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
AL WALEEB & GUNUB VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.4-Water Reservior Plat form & Pump Control Switch Room-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A 0.00
B. SUPER-STRUCTURE
1 BLOCK WORK USD 0.00
2 ROOFING USD 0.00
3 METAL WORK USD 0.00
4 STEEL STRUCTURE USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No additional allowance for working space to be considered for measurement. The site clearing area shall be the net built-up area including aprons, open ditch, entrance step and ramp. m2 10.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for the ground floor from the Average Natural Ground Floor Level (A.N.G.F.L.) to a depth not exceeding 150 cm. The volume of excavation shall be measured only over the net built-up area of the building footprint, excluding aprons, open ditches, and ramps. Working allowance: An additional 0.50 m width on each side of the excavation shall be included to allow for proper working space. Reference level (A.N.G.F.L.): The A.N.G.F.L. is defined as the average of the topographic ground levels taken at the building footprint prior to any excavation works, reduced by 20 cm to account for above work item site clearing. m3 3.50 0.00
1.3 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level. Note: measurement shall include 150 cm working space in each side for trench excavation. m3 3.10 0.00
1.4 Back fill under hard core and around the building with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 3.00 0.00
1.5 Back fill around masonry wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 2.00 0.00
1.6 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material. Disposal shall be measured as the net volume arising from the void created by the excavation, less excavated material backfill, filled and wheel spread within site or left stockpiled. m3 8.60 0.00
1.7 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone.only under concrete channel. m2 1.50 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately.
2.1 5 cm thick lean concrete in grade/class C-5 concrete, minimum cement content of 150 kg/m3 :
A. Under ground floor slab m2 6.00 0.00
B. Under masonry foundation wall m2 5.40 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
A. In 20 cm thick slab m2 6.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
To slab edge m2 2.20 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
A. For slab on grade
Dia 10 mm deformed bar Kg 74.04 0.00
Total carried to summary USD 0.00
3.1 50 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 4.28 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
Walls shall be constructed from class 'B' hollow concrete block (H.C.B.). The blocks shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the blocks shall be in such a way that good key for plasterer is obtained on both side.
1.1 Supply and lay 20cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for pointing.Price shall include recessed pointing. m2 9.12 0.00
Total carried to summary USD 0.00
1.1 Supply and fix approved standard pre-painted 0.35mm thick corrugated iron sheet (C.I.S.) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). m2 4.62 0.00
Total carried to summary USD 0.00
3.1 Double-leaf metal door constructed from 40×40×3 mm RHS steel for vertical and horizontal framing, fully welded and braced with similar RHS sections as shown in the Architectural drawings. Door to be infilled with galvanized steel wire mesh 2.5 mm dia. at 25 mm c/c, welded to frame. Include all necessary welding, surface preparation, one coat of primer, and two coats of synthetic enamel paint to all steel surfaces. All work to conform to detailed drawings and relevant standards.
A. Door D1 size 170 x 150 cm. no 1.00 0.00
3.2 Wire mesh covering for pump control switch side walls made of galvanized steel wire mesh 2.5 mm diameter, spaced at 25 mm c/c, fixed securely to RHS structural frame using appropriate clamps or welding as shown on the drawings. The work includes cutting, fitting, welding (where required), surface preparation, one coat of metal primer, and two coats of synthetic enamel paint on all steel members. All materials and workmanship shall comply with the relevant standards and detailed drawings. m2 2.00 0.00
Total carried to summary USD 0.00
4 STEEL STRUCTURE
4.1 Supply, fabricate, assemble, and erect steel structures using RHS and CHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel Structure Column
Steel structure columns are vertical primary load-bearing members, transferring axial loads (and occasionally bending) from trusses to foundations. Since columns are in direct contact with water during cleaning, apply bituminous damp-proof paint at the column base up to a height of 300 mm (30 cm) to prevent corrosion and moisture penetration.
A.1 steel structure column using two RHS sections, 60 × 60 × 3 mm. not welded part single unit. ml 6.90 0.00
B. Steel Structure Column Beam
The beam shall be welded column to column just below the top plate level where truss and column connected. At the end of the beam where there is no steel column. it connected with the existing building it will be fixed with plate at the concrete column/tie beam
B.1 RHS 60 x 60 x 3mm beam ml 6.00 0.00
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards.
C.1 RHS 80 x 60 x 3mm rafter ml 4.00 0.00
D. RHS Purlins 0.00
D.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 100 x 40 x 3mm L= 60mm angle iron. Price include angle iron. ml 5.70 0.00
4.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate size 150 x 150 x 8mm with 4 dia.18 slotted holes for dia. 16 J-bolt No 8.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
AL WALEEB & GUNUB VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.5-Septic Tank & Soak Away Pit-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. Price shall include all working space allowances deemed necessary. m2 25.00 0.00
1.2 Bulk excavation in ordinary soil to a depth not exceeding 150 cm starting from the natural ground level. Note: measurement shall include 25 cm working space for bulk excavation. m3 69.00 0.00
1.3 Ditto but from 150 cm to 300 cm m3 41.00 0.00
1.4 Back fill around retaining wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 27.00 0.00
1.5 Spread coars gravel at the bottom of soak away m3 1.41 0.00
1.6 Ditto as above but spread fine gravel fill between coarse gravel and 0.4 cm average sand fill. m3 0.35 0.00
1.7 Ditto as above but spread 0.4cm average sand fill between fine gravel & 0.2cm diameter fine sand. m3 0.35 0.00
1.8 Ditto as above but spread top layer soak away 0.2cm average fine sand fill. m3 0.55 0.00
1.9 Cart away excavated material from the site as approved by the Engineer. Soil shall be damped more than 1km. m3 115.00 0.00
1.10 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
A) The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube moulds necessary for the purpose and for submitting reports of the tests to the Engineer.
B) Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/ class C-5 concrete, minimum cement content of 150 kg/m3 :
2.1.1 Under septic tank bottom slab m2 13.00 0.00
2.1.2 Unde soak away pit m2 7.60 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In 20 cm thick septic tank bottom slab m2 13.00 0.00
2.2.2 In 20 cm thick septic tank top slab including ring beam m2 10.00 0.00
2.2.3 In 15 cm thick soak away top slab m2 5.00 0.00
2.3 Formwork shall be timbered or steel or a combination of two, sufficient to contain the wet concrete without leakage. Enough to support temporary loading and pressure from placing Compaction or vibration without displacement or appreciable deflection.
2.3.1 To septic tank bottom slab m2 3.20 0.00
2.3.2 To septic tank top slab including ring beam m2 7.00 0.00
2.3.4 To k top slab including ring beam m2 3.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 Bottom Slab
A. Diam 12mm Deformed bar. kg 214.00 0.00
A. Diam 12mm Deformed bar. kg 147.00 0.00
2.4.3 Tie submerged beam
A. Diam 10mm Deformed bar. kg 77.00 0.00
B. Diam 8mm Deformed bar for distribution bar kg 45.00 0.00
2.4.4 Soak away top slab
A. Diam 12mm Deformed bar. kg 75.00 0.00
B. Diam 8mm Deformed bar for distribution bar kg 31.00 0.00
2.10 Allow lump sum amount 60 x 60 cm concrete manhole cover Ls 2.00 0.00
2.11 Supply & fix wooden or equivalent 6,, thick wooden baffle as shown the detail drawing and Engineer’s approval Ls 1.00 0.00
Total carried to summary USD 0.00
3.1 Construct average 60 cm at bottom up to 120 cm & 50 cm thick width thick Basaltic or equivalent stone masonry septic tank retaining foundation wall bedded in cement sand mortar (1:4) below NGL. For septic wall. m3 15.00 0.00
3.2 Ditto as above but 50 cm thick masonry wall for soak away pit m3 9.00 0.00
3.3 Septic tank chamber partition:-Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) with stiffeners bedded and jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. Price shall include plastering m2 2.00 0.00
3.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to internal & external masonry wall surfaces. m2 52.00 0.00
3.5 Ditto as above item but for HCB chamber partition wall. m2 4.00 0.00
3.6 Allow lumps amount of sanitary uPVC work for septic tank inlet, chamber partition and out let pipes to soak away pit. ls 1.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
AL WALEEB & GUNUB VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.6-Cattle Waste Holding Tank
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including 25 cm thick working allowance in each side. m2 21.90 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to an average depth of 150 cm. Note: measurement shall include the net area of the site clearing work. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. m3 32.85 0.00
1.3 Ditto as above item but to a depth above 150 cm but not exceeding 300 cm from reduced ground level. m3 18.61 0.00
1.4 Selected borrow fill around retaining wall with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 24.24 0.00
1.5 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 55.85 0.00
1.6 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described. All works shall be as per the structural general note.
2.1 5 cm thick lean concrete in grade/class C-5, minimum cement content of 150 kg/m3 :
2.1.1 Under bottom holding tank m2 17.00 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In 30 cm thick bottom slab m2 17.00 0.00
2.2.2 In 20 cm thick retaining/shear wall. m2 30.80 0.00
2.2.3 In 20 cm thick suspended top slab m2 11.78 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To bottom slab m2 5.58 0.00
2.3.2 To retaining/shear wall. m2 61.60 0.00
2.3.3 To suspended top slab m2 11.94 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For bottom slab
Dia 12 mm deformed bar Kg 444.00 0.00
2.4.2 For retaining/shear wall
Dia 8 mm deformed bar Kg 89.00 0.00
Dia 12 mm deformed bar Kg 1,025.00 0.00
2.4.3 For floor slab on grade
Dia 8 mm deformed bar Kg 12.00 0.00
Dia 12 mm deformed bar Kg 271.00 0.00
2.5 Internal surfaces of concrete cattle waste holing tank to be thoroughly cleaned and prepared by removing all dirt, laitance, grease, oil, algae, and loose material; all honeycombed, defective, or uneven surfaces to be repaired and made good with approved cement–sand mortar to provide a sound and smooth substrate. Supply and apply a two-component elastomeric cementitious waterproofing coating, potable-water approved, such as Nitocote CM210 or approved equivalent, to floors and walls, strictly in accordance with the manufacturer’s written instructions regarding surface preparation, priming, number of coats, minimum dry film thickness, curing, and protection. All pipe penetrations and exposed services within the tank to be treated with approved bituminous paint or compatible sealing system prior to application of the waterproofing coating. Item to include all materials, labor, tools, equipment, surface preparation, application, testing, protection, and completion of the works. Waterproofing system to be applied by the manufacturer or an approved authorized applicator, providing material and workmanship guarantees to the Employer. m2 38.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
AL WALEEB & GUNUB VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.7-Site Works-Civil
1.1-Hard-scaping USD 0.00
1.2- Soft Scaping USD 0.00
2 Perimeter Fence with Gate USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 Hard-scaping
1.1.1 Clearing and grubbing of existing surface, including removal of vegetation, topsoil, and debris, to a depth of 40 cm and disposal as directed by the Engineer. m2 135.80 0.00
1.1.2 Selected fill to 95% MDD, including watering and rolling as shown the drawing m3 27.16 0.00
1.1.3 Supply, place, spread, water, and compact approved selected gravel material as capping layer to compound surface floor, including leveling, dressing to required camber/slope, and compaction to specified density as per specification and Engineer’s approval. m2 135.80 0.00
1.1.4 Supply and place crushed stone base course (C-4) 10 cm thick, including spreading, watering, and compaction to 95% MDD. m3 23.09 0.00
1.1.5 Supply, lay, and compact 7 cm thick Asphalt Binder Course using approved bituminous mix, laid in well-prepared and compacted layers over an approved base, in accordance with specifications and Engineer’s instructions. m2 135.80 0.00
1.1.6 Edge restraint using concrete curb (15 × 40 cm) including excavation, formwork, placing, and finishing. ml 56.20 0.00
1.1.7 Supply and install resin bound gravel surface comprising washed and dried natural aggregates mixed with UV-stable polyurethane resin, laid to specified thickness over a prepared and approved base, including finishing to a smooth, permeable, and durable surface in accordance with the specifications and Engineer’s instructions. m2 135.80 0.00
1.1.8 Supply and lay hand-dressed natural basalt/granite cobblestones (approx. 150×150×150 mm), tightly packed with joints filled with sand or cement-sand slurry as directed by the Engineer. The work shall includes all the necessary incidental works to complete the work such as surface preparation work. excavation, fill and cement sand slurry as per the detail Ar. drawing. The edge restaint curb stone measured in item 1.1.6. m2 19.60 0.00
Total Carried to Summary (USD) 0.00
1.2 Soft-soaping
1.2.1 Clearing and grubbing of existing surface, including removal of vegetation, topsoil, and debris, to a depth of 60 cm and disposal as directed by the Engineer. m3 37.80 0.00
1.2.2 Supply, place, spread, water, and lightly compact approved loamy (loam) soil for soft landscaping works, free from stones larger than 20 mm, roots, debris, weeds, and other deleterious materials, and suitable for plant growth. Loam soil shall have good drainage and adequate organic content, as approved by the Engineer. The rate shall include supply of soil, transportation, placement to the required levels and thicknesses, watering, light compaction, trimming, leveling, and all labor, tools, and equipment necessary to complete the work as specified. avg. depth 300mm m3 18.90 0.00
1.2.3 Supply, well decomposed animal manure or equivalent organic material to be mixed with the topsoil averagely 300mm and to use in backfilling of planting pits. Price shall include all the necessary works to complete the work. Provide 1kg sample and details of supplier With quotation for Landscape Architect’s approval. m3 18.90 0.00
1.2.4 Provide and plant grass as selected by the landscape architect. price includes grass as per the detail Architectural drawing. m2 63.00 0.00
1.2.5 Maintenance of lawn , grass, trees, shrubs, seasonal flower bed, other plantation and horticultural operations for weeding, watering, spreading of manure, good earth , fertilizers, spray of insecticides, fungicides, hoeing, pruning of tree/shrubs/hedge plants grassing garden swords, anti-termite treatment. Rates to include cost of material, all labor, tools & tackles, cost of manure, earth, fertilizer, pesticides etc. and also providing complete arrangement at site/sites for grass cutting by brand new power run lawn mower with skilled machine man & labor, diesel, lubricant to ensure mowing on barns and by manual labor through garden sward on the slop of under pass of the grass at least 3 times / month complete Month 2.00 0.00
1.2.6 Provide plants specially selected and nursery grown shade trees. Price supply of plants and planting as per the detail Architectural drawing. No 11.00 0.00
Total Carried to Summary (USD) 0.00
2 Galvanized Steel Wire Mesh Perimeter Fence with Gate
2.1 Supply, fabricate, and install galvanized steel wire mesh perimeter fence comprising 60 × 60 × 3 mm RHS vertical posts spaced at 2500 mm centers, fixed in concrete pad foundations, with top and bottom horizontal rails (60 × 60 × 3 mm RHS). The fence infill to be galvanized steel wire mesh (Ø 2.5 mm, 25 × 25 mm grid) securely fixed to the frame. The rate shall include excavation, concrete works, anti-rust treatment, metal painting, and provision of a main gate (2700 mm width) fabricated from similar materials, complete with all accessories, in accordance with specifications and Engineer’s instructions. ml 90.00 0.00
Total Carried to Summary (USD) 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
AL WALEEB & GUNUB VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.8-Site Works-Electrical
ITEM DESCRIPTION UNIT QTY RATE TOTAL
1 Manhole for Electrical Systems
. Construct rectangular double red burnt brick electrical manholes of internal dimensions 800mm × 800mm × 700mm in accordance with the detail drawings and specifications. The manhole shall comprise 250mm thick double red burnt brick masonry walls, internally plastered with cement-sand mortar, a 100mm thick reinforced concrete base slab, and a 100mm thick removable reinforced concrete cover slab complete with flush-type cover, all as approved by the Engineer. The rate shall include excavation to the required depth, disposal/cart-away of surplus excavated material, back-filling and compaction around the structure, supply and placement of concrete, reinforcement, form-work, brick masonry, plastering, curing, and all associated civil works, labor, materials, tools, and incidentals necessary for the complete and proper construction and functioning of the electrical manhole system. Set 7.00 0.00
2 Light Fittings and Lamps 0.00
. Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing. IEC 60969 standards or equivalent and type approved 0.00
LED Solar Street Lights for Outdoor, atleast 15000 Lumens DA high-brightness, all-in-one solar street light for perimeter lighting, powered by sunlight with no electricity costs. Key Specifications Brightness: ≥15,000 lumens (bright as daylight) Light Type: LED (SMD 2835 or CREE 3030 chips) Color: Cool white (6000K–6500K) Solar Panel: 150-watt monocrystalline (charges in 6 hours) Battery: LiFePO4, ≥7-year lifespan, 3-day backup capacity. Operation: Dusk-to-dawn (auto on/off with daylight sensor) Motion sensor (full brightness on movement, dims to save energy) Remote control (adjust brightness, set timers) Weatherproof: IP65 (waterproof, dustproof, works in rain or heat) Material: Aluminum housing, tempered glass cover Runtime: 11 hours after 6-hour charge; up to 18 hours in dim mode Installation: Pole or wall mount (6ms height), no wiring needed Durability: Works in -22°F to 140°F; 50,000+ hour lifespan Warranty: 3–5 years No 8.00 0.00
3 Documentation 0.00
. Engineering, electrical installation as built drawings and O&M manuals. Qualified Set 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
AL WALEEB & GUNUB VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.9-Site Works-Sanitary
SITE SANITARY WORKS
1 SITE WATER SUPPLY SYSTEMS USD 0.00
2 SITE WASTE WATER DRAINAGE SYSTEMS USD 0.00
3 ROOF & SURFACE RAIN WATER DRAINAGE SYSTEM USD 0.00
4 GENERAL ITEMS USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 WATER SUPPLY SYSTEMS
1.1 Site Water Supply Piping Systems
1.1.1 Supply,laying and test Cold drinking water pipes from municipality line to ground water tank(GWT). The pipe shall be PN16 DN50 High Density Polyethylene (HDPE) made of pure PE 100 rawmaterial and be laid in trench as shown in the sanitary site drawing. Provide 100mm thick sand bedding material rammed and tamped and 150mm thick approved material to cover the pipe all as per the typical site trench section and detail.Unit price shall include excavation, backfilling and cart away the excess quantity with all assistance civil works and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 10.00 0.00
1.1.2 Supply,laying and test Cold drinking water pipes from ground water tank(GWT) to transfer pump and to elevated water tank(EWT). The pipe shall be PN16 DN32 High Density Polyethylene (HDPE) made of pure PE 100 rawmaterial and be laid in trench as shown in the sanitary site drawing. Provide 100mm thick sand bedding material rammed and tamped and 150mm thick approved material to cover the pipe all as per the typical site trench section and detail.Unit price shall include excavation, backfilling and cart away the excess quantity with all assistance civil works and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 12.00 0.00
1.1.3 Supply,laying and test Cold drinking water pipes from gelevated water tank(EWT) to building block entrance where branched to water points (usable water supply)and nearby drainage lines (for overflow & washout piping). The pipe shall be PN10 DN40 PPR made of pure original rawmaterial and be laid in trench as shown in the sanitary site drawing. The unit price shall include piping bottom drain with valves piping system from EWT connected with overflow and connected to near by drainage ditch, air vent with insect screen and all support fixting work with related civil works. The unit price shall also consider and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 20.00 0.00
1.2 Supply and fix chrome service valves/isolation valve of approved standard before wet areas, or hand wash basins, water closets and other fixtures. Complete with unions, elastic water proofing, hand wheels of normal quality and with all other necessary accessories.
1.3 Construct standard a double brick wall,R.C base slab & R.C cover valve chamber compatible to valve size at specific position shown on the drawing with the respective PN6 bronze isolating valve.The price shall include excavation of a pit, cart away and backfilling.
1.3.1 Valve chamber with DN : variable isolation valves. № 4.00 0.00
1.4 Supply, installation, testing, and commissioning of domestic cold-water meter of multi-jet or volumetric type, suitable for potable water application in the animal health clinic water distribution system, complying with ISO 4064 / OIML R49 standards.Water meter shall be of DN50 nominal size, with brass or epoxy-coated ductile iron body, sealed dry dial register, and corrosion-resistant internal components. The meter shall be Class B or R80 accuracy, with a nominal working pressure of 16 bar, and maximum temperature 30°C.Each meter shall include couplings, strainer, and non-return valve, islation valve at each end and be installed in an accessible, ventilated, and protected meter chamber.All meters shall be factory-calibrated, certified, and permanently marked with serial number, flow class, size, and manufacturer identification. № 1.00 0.00
1.4 Water Reservoirs
1.4.1 Elevated water tank[EWT]
Supply, install, and commission a high-quality fiberglass (or equivalent) water tank with a nominal capacity of 2,500 liters for potable water storage, elevated 6 meters above ground on a support structure as per the provided sanitary and structural detail drawings. Tank Specifications: Material: Fiberglass reinforced plastic (FRP) or equivalent, approved for potable water storage, compliant with relevant standards ( BS EN 13280 or equivalent). Capacity: 2,500 liters (nominal). Design: Vertical seated(bottom diameter < 2m , suitable for external exposure with UV-resistant coating to withstand harsh weather conditions. Accessories: Manhole: Watertight manhole (minimum 600 mm diameter) with a lockable, weather-resistant cover to prevent contamination and ensure safety. Overflow Pipe: Minimum DN50, directed to a near by rain water drainage point with insect-proof mesh. Level Sensor: Automatic water level sensor/controller to start/stop the transfer pump. Inlet Pipe: Minimum DN32, fitted with a PN16 bronze gate valve. Outlet Pipe: Minimum DN40, fitted with a PN16 bronze gate valve and an expansion joint to accommodate to absorb any pipe movement. Drain Pipe: Minimum DN50, fitted with a PN16 bronze gate valve for complete tank drainage, directed to a designated drainage point. Fittings: All pipes and fittings shall be corrosion-resistant, suitable for potable water, and compliant with relevant standards (BS EN 545 or equivalent). Set 1.00 0.00
1.4.2 Ground water tank[GWT]
Supply, install, and commission a high-quality fiberglass (or equivalent) water tank with a nominal capacity of 5000 liters for potable water storage, at ground level as per the provided sanitary and structural detail drawings. Tank Specifications: Material: Fiberglass reinforced plastic (FRP) or equivalent, approved for potable water storage, compliant with relevant standards ( BS EN 13280 or equivalent). Capacity: 5000 liters (nominal). Design: Vertical seated(bottom diameter < 2m , suitable for external exposure with UV-resistant coating to withstand harsh weather conditions. Accessories: Manhole: Watertight manhole (minimum 600 mm diameter) with a lockable, weather-resistant cover to prevent contamination and ensure safety. Overflow Pipe: Minimum DN50, directed to a near by rain water drainage point with insect-proof mesh. Level Sensor: Automatic water level sensor/controller to start/stop the transfer pump. Inlet Pipe: Minimum DN50, fitted with a PN16 bronze gate valve. Outlet Pipe: Minimum DN32, fitted with a PN16 bronze gate valve and an expansion joint to accommodate to absorb any pipe movement. Drain Pipe: Minimum DN50, fitted with a PN16 bronze gate valve for complete tank drainage, directed to a designated drainage point. Fittings: All pipes and fittings shall be corrosion-resistant, suitable for potable water, and compliant with relevant standards (BS EN 545 or equivalent). set 1.00 0.00
1.5 Potable Cold Water Pumping system
1.5.1 Supply, fix, test and commission approved quality duplex vertical inline water pumps to push potable water to elevated water tanks to be distributed to every demanding buildings of the compound .As per the manufacturer's instruction and drawing shown . Price shall include all the necessary valves( one-way and stop valves), water hammer arrestor , common base plate ,automatic level control sensors & switches to start/off & to protect pumps from dry running & control panel .The price shall include all the necessary accessories required for the proper operation of the system but not specified or shown on the drawing. The pump shall be equiped with a single-phase transfer pump control board to manage water levels in an elevated water tank and ground water tank, featuring a compact IP65-rated enclosure (stainless steel or powder-coated mild steel), industrial-grade PLC, 4-inch touchscreen HMI for real-time monitoring and manual override, ultrasonic or float-type level sensors (2 nos. per tank) for accurate water level detection, control logic for automatic pump start/stop based on setpoints with sequential operation to minimize load, thermal overload relays, dry run protection via sensors or current monitoring, single-phase failure protection, surge arrestors, flame-retardant copper wiring, dedicated earthing, real-time pump status and alarm monitoring (high/low water levels, pump faults) on HMI, compliant with IEC standards and local regulations, complete with installation, testing, as-built drawings, operation manuals, training, and a 2-year warranty, designed for a 10-year operational life. Flow rate[LPS] = 0.694 @ 10 meter head Reference Model : Brand: DAB Model:KLPE 40-1200 with respective control systems and sensors. Set 1.00 0.00
Total Carried to summary USD 0.00
2 WASTE WATER DRAINAGE SYSTEMS
2.1 Providing, laying and jointing of internal uPVC PN-10 waste pipes with all uPVC pipe fittings including jointing with solvent cement joints and testing of joints etc. according to where shown on the drawings.Complete with all the necessary fittings. Provide cleaning detail for all waste water riser pipes as per the detail drawing.
2.1.2 Diameter 110mm ml 14.00 0.00
2.1.3 Diameter 160mm ml 37.00 0.00
2.1.3 Diameter 300mm ml 14.00 0.00
2.1.4 Construct rectangular manhole out of 250mm thick double brick walls,internal dimension 600mm x 600mm x 850mm (average depth),internally plastered with three coats of cement/sand mix ratio1:3 ,on a base of precast R.C slab of size ,1300mm x 1300mm x100mm , including benching and bottom channeling with mass concrete.Slab shall be reinforced with dia.8mm reinforcement bar c/c 130mm bothways. Provide 150mm thick granular materials beneath the slab,on a compacted earth . Manhole shall have precast R.C cover slab, each,size, 740mm x 740mm x 100mmreinforced with diameter 8mm steel barc/c140mm bothways,including diameter 14mm steel ring handle with supporter bar all in accordance with the given detail drawings .Unit price shall include excavation of the pitto a depth of 800mm (average) and cart away of the excavated soil. № 8.00 0.00
2.1.5 Ditto No 2.1.4 but size(length x width x depth)[mm]= 400 x 400 x 400 gully trap for gray water drainage № 3.00 0.00
Total Carried to summary USD 0.00
3 ROOF WATER DRAINAGE SYSTEM
3.10 Construct a rectangular open channel designed to collect and convey storm water runoff from around the building perimeter. The channel is made of 20cm thick masonry bed, 40cm thick side masonry wall and whenever the walk way, ramp and car way crossing the top part will be covered with pre case concrete cover. The internal part of the channel shall be plastered. The work shall include excavation, cart away , fill, masonry bed, wall, plastering , pre-cast concrete cover at crossing and all incidental work to complete work as per the project’s detailed drawings. The channel longitudinal slope of 1% (1:100) shall be maintained. Where the natural ground slope exceeds 1%, the contractor shall follow the greater natural ground slope to ensure positive drainage and avoid ponding. ml 90.00 0.00
Minimum Ditch-: SIZE[mmXmm] = 225 X 200
3.20 Ditto No 2.1.3 but for roof and surface water drainage system. № 10.00 0.00
3.30 Ditto No 2.1.4 but for roof and surface water drainage system. № 2.00 0.00
3.40 SURFACE WATER DRAINAGE CONNECTION TO ROADSIDE DRAINAGE LINE Scope includes but is not limited to: • Supply and installation of DN300 uPVC pipe (Class/SN as per local municipality standard for underground non-pressure drainage) from the manhole inside the clinic compound to the roadside drainage line. Total length to be verified on-site. • Pipe shall be laid at a gradient of 0.5% to 1% (1 in 200 to 1 in 100) to ensure self-cleansing velocity and prevent siltation. • Connection to existing manhole inside clinic compound (600mm x 600mm internal size, with invert level above road side drainage invert). Includes breaking into manhole wall, making good, and providing a proper connection. • Connection to roadside drainage line (standard road side channel/drain). Includes forming a proper junction at the outfall point. The connecting pipe's invert level shall be set above the soffit (crown) of the roadside drain to prevent backflow during high-flow conditions in the main drain. • Supply and installation of all necessary fittings (bends, junctions, couplings, adaptors) as required for directional changes and connections. • All civil works: Excavation (including breaking existing surfaces), trenching, pipe bedding (sand/gravel), backfilling, compaction, and surface restoration to original condition. • Testing of the installed pipeline by means of water or air testing to ensure leak-tightness prior to backfilling. • All necessary permits, approvals, and inspections as required by the local municipality for connection to the public drainage system. Note: Contractor to verify all site levels, invert levels of the existing manhole and roadside drain, and confirm the required slope is achievable before commencement. All works to be carried out as per local municipality standards and approved drawings. ls 1.00 0.00
Total carried to summary USD 0.00
4 GENERAL ITEMS
4.1 Allow for Testing and commissioning of the entire plumbing installation by a Chartered Mechanical Engineer and obtaining a Test Certificate (3rd party testing to approval of the Engineer) including all off-site and factory testing; inspections to demonstrate compliance with relevant standards, operating the completed installation and submitting all relevant test records and authority approval. LS 1.00 0.00
4.2 All sanitary fittings supplied shall be provided with a minimum 5 year warranty, issued jointly and severally by the local supplier and the manufacturer. LS 1.00 0.00
4.3 Allow for preparation of Operationa and Maintenance Manual including site users training for the O & M Maual of all plumbing and mechanical appliances. LS 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
AL WALEEB & GUNUB VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bill No.10-Signage
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 Directory Signs
Design, supply and install international standard Boy's, Girl's & PWD Toilet directional sign complete with pictogram (Girl's, Girl's & PWD toilet sign symbol) plus directional arrow that leading to the toilets. The sign shall also consist text “Boy's , Girl's & PWDToilet.” Sign shall be minimum size 300 mm × 400 mm, high quality tin: tin sign with retro design, metal tin, long-term use, not easy to damage, smooth surface, ...with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 1.00 0.00
2 Room Identication Signs
Design and supply signage with room number in accordance with this specification and as directed by the Architect. The material shall be made of 3-5mm thick wall mounted Acrylic signs. The size shall be 250mm x 30mm and letter height shall be 50-70mm for room number, 25-40mm room name letters and braille and tactile characters where applicable. The color and contrast between the text and background shall be high and the color shall be consistent with the veternary clinic branding (if any) or as per the Architect approval. The topography and information shall be Room number: Bold, large font (sans serif preferred), Room function/name: Smaller font beneath the number (e.g., Room 101 – Office) and Braille/tactile lettering placed below the printed text. The signage shall be fixed to the wall at 1.4–1.5 m above floor to centerline of sign on the latch side of the door, or directly on the door if wall space is not available and it shall be fixed with secure concealed fasteners or adhesive (depending on wall/door material). The supplier shall produce and submit Mock-ups for approval before mass production. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect.
2.1 Isolation Room No 1.00 0.00
2.2 Office No 1.00 0.00
2.3 X-ray room No 1.00 0.00
2.4 Preparation room No 1.00 0.00
2.5 Electric Room No 1.00 0.00
2.6 Rest rooms and Janitors with pictogram of gents, ladies and PWD No 4.00 0.00
2.7 Treatment room No 1.00 0.00
2.8 laboratory No 1.00 0.00
3 Safety and Compliance Signs
4.1 Design, supply and install Emergency Exit Sign in accordance with this specification and as directed by the Architect. The material shall be made of flame-retardant, impact-resistant ABS clear acrylic plate and shall comply with BS EN ISO 7010 Exit Symbol (E001) and shall have Multi-installation system: Hanging, wall or surface mounted depending on the location. The size of the letter height shall be minimum 150mm with a stroke width 19mm, color contrast to be white letters on green background and the sign shall consist pictogram of running man symbol + directional arrow that leading to exit doors depending the location of the Emergency sign plan on the drawing. The sign shall support internally illuminated and visible in smoke and low light and are powered by dual power 220-240V AC (primary), automatic 90 minutes minimum battery backup (Lithium-ion battery).The sign shall be fixed to exist access point at 2.00–2.50 m above floor level. The supplier shall produce and submit Mock-ups for approval before mass production or procurement. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect. No 4.00 0.00
4.2 Design, supply and install Entrance Sign in accordance with this specification and as directed by the Architect. The material shall be made of flame-retardant, impact-resistant ABS clear acrylic plate and shall comply with BS EN ISO 7010 Exit Symbol (E001) and shall have Multi-installation system: Hanging, wall or surface mounted depending on the location. The size of the letter height shall be minimum 150mm with a stroke width 19mm, color contrast to be white letters on green background and the sign shall consist text+ directional arrow that leading to entrance.The sign shall be fixed to entrance access point at 2.00–2.50 m above floor level. The supplier shall produce and submit Mock-ups for approval before mass production or procurement. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect. No 3.00 0.00
4.3 Supply and fix 3mm rigid PVC/acrylic Fire Extinguisher sign (300mm x 100mm) with 50mm high ISO-compliant white lettering on red background, including all fixings and installation. No 7.00 0.00
4.4 Supply directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. Supply and install directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. No 1.00 0.00
4.5 Supply emergency assembly point safety sign complete with standard ISO 7010 pictogram (E007: four people symbol) and text “EMERGENCY ASSEMBLY POINT.” Sign shall be fabricated from 3 mm thick photo luminescent rigid PVC or aluminum composite panel, minimum size 600 mm × 600 mm, with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
AL WALEEB & GUNUB VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.10-Day Works
1 LABOUR USD 0.00
2 MATERIAL USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
(ALL PROVISIONAL)
In accordance with the Conditions of Contract, the Contractor will be paid day work rates for extra work that cannot properly be measured and valued, and the Contractor is to insert in the space provided below the basic rates and costs of labour,materials and plant as described hereunder:-
1.1 MASON hours 1 0.00
1.2 CARPENTER hours 1 0.00
1.3 SCAFFOLDER hours 1 0.00
1.4 JOINER hours 1 0.00
1.5 PLUMBER hours 1 0.00
1.6 ELECTRICIAN hours 1 0.00
1.7 PLASTERER hours 1 0.00
1.8 PAINTER hours 1 0.00
1.9 LABOURER hours 1 0.00
TOTAL in USD 0.00
1.10 To the basic net rates of labor used for work carried out on day works, an addition 25% percent which is to include for task work and incentive schemes, tools, standing, scaffolding, supervision, insurance, transport profit and overheads.
To collection of Labour Day works 0.00
2.1 Cement Per Tonne 1 0.00
2.3 Aggregate (grade 25 - 5mm) m3 14 0.00
2.4 Steel reinforcement
(i) Mild steel bar Kg 1 0.00
(ii) High tensile bar Kg 1 0.00
2.5 Timber formwork Per SQ.M 1 0.00
2.6 Paint, Gloss Per 4 Litres 1 0.00
2.7 Paint, Emulsion Per 4 Litres 1 0.00
2.8 Mahogany Varnish Per 4 Litres 1 0.00
2.9 100mm diameter uPVC rainwater downpipe 6M Per Each 1 0.00
2.10 Ditto bends Per Each 1 0.00
2.11 Ditto offsets Per Each 1 0.00
2.12 Ditto watershoe Per Each 1 0.00
2.13 Fixing brackets Per Each 1 0.00
2.14 Fixing screws Per Packet 1 0.00
2.15 75mm thick x 375mm wide weather/throated cills Per M 1 0.00
2.16 4 mm Clear sheet glass Per SQ.M. 1 0.00
2.17 100mm long Flush bolt Per Each 1 0.00
2.18 Indicator Signage Per Each 1 0.00
2.19 400mm x 200mm x 100mm hollow concrete blocks Per 1000 1 0.00
2.20 300mm x300mm x 8mm Ceramic floor tiles Per SQ.M. 1 0.00
2.21 150mm x 150mm x 6mm white glazed wall tiles Per SQ.M. 1 0.00
2.22 25mm x 3mm earth copper tape Per M 1 0.00
2.23 35mmsq bare copper cable Per M 1 0.00
2.24 6mmsq bare copper cable Per M 1 0.00
2.25 2.5mmsq. TWE copper cable Per M 1 0.00
2.26 2.5mmsq. SC PVC-I copper cable Per M 1 0.00
2.27 4.0mmsq. SC PVC-I copper cable Per M 1 0.00
2.28 10.0mmsq. 3C PVC-SWA-PVC copper cable Per M 1 0.00
2.29 20mm diameter galvanised steel tubing 6M Per M 1 0.00
2.30 20mm diameter galvanised steel tee Per Each 1 0.00
2.31 20-15mm diameter reducer Per Each 1 0.00
2.32 110mm diameter uPVC soil pipe 6M Per Each 1 0.00
2.33 50mm ditto waste pipe 6M Per Each 1 0.00
2.34 110mm ditto single branch access Per Each 1 0.00
2.35 50mm ditto sweep tee Per Each 1 0.00
2.36 Single bowl, single drainer stainless steel sink size 2000 x 600mm Per Each 1 0.00
To Collection 0.00
2.37 To the basic nett rates of materials used for work carried out on dayworks, an addition of 25% which is to include for unloading and storing as necessary, the use of hand plant, and machinery etc. available on site, profit and overheads.
To collection of Material Day works 0.00
3.1 Portable Compressor with 2 breakers or equivalent with 1500 mm hoses and reels hours 40 0.00
3.2 Damp Truck (0.75 tonne) hours 40 0.00
3.3 Lorry seven tonne tipper hours 40 0.00
3.4 Concrete Mixer (14/10) complete for weight batch mixing hours 40 0.00
3.5 50 mm self priming centrifugal pump with hose and ancillary equipment hours 40 0.00
3.6 Concrete Vibrators hours 40 0.00
To Collection 0.00
3.7 To the basic rates of plant used for work carried out on dayworks, an addition of 25% per cent, which is to include for driver and/or attendance, fuel and consumable stores supervision, insurance, road licence,profit and overheads.
To collection of Plant Day works 0.00
Name of Signatory:
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Exavation Work
ITEM TYPE SIZE No M3
Exavation & Earthwork
1.01 site clear
cad area including appron,ditch
1.02. Bulk Excavation to reduce level
1.03. Footing Excavation
1.04. ditto but from 1.50-3.00m
1.05.Trench Excavation
with 0.15 allowance each side
1.05. Back fill under hard core
ddt stone masonry wall
1.06.Ditto but around footing
Excavation Volume
ddt lean concrete
ddt footing pad
ddt column 0.00
1.07.Ditto but around masonry
with 0.25 allowance each side
1.08. Cart away
1.09. hard core
1.10. Dewatering
3.01. construction joint
10mm thich joint filler/sila or fiber board
4. Masonry Item
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Sub-Structure Concrete
CONCRETE FORM WORK
Type Size No Total Size Total
2.1. Lean Concrete
Total 118.86 m2
Under masonry wall
Under hard core
2.2 C -25 CONCRETE
Foundation Column
Total 5.04 67.20
200mm thick slab
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Super-Structure Concrete
CONCRETE FORM WORK
1.1. C-250 Concrete
A. Elevation Column
From Ground-roof floor
150mm Concrete gutter
Total 9.05 m3 129.05 m2
100mmSun breaker
Total 22.11 m3 23.32 m2
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Architectural
ITEM TYPE SIZE No Total
2.01. 20cm thick H.C.B wall screening
2.01. 20cm thick H.C.B wall
ddt opening 0.00
3. Roofing Work
3.04. Valley gutter
Gutter light wt concrete
Gutter water proofing
B. Steel Structure Beam
C. RHS Truss system
C.1 RHS 60 x 60 x 3mm upper and lower member
Total length 188.60
Unit Wt. for the section 5.37
Total Kg 1,012.67
C.2 RHS 50 x 50 x 3mm upper and lower member
Total length 24.00
Unit Wt. for the section 4.43
Total Kg 106.26
C.3 RHS 40 x 40 x 3mm Diagonal & verical member
Total length 181.85
Unit Wt. for the section 3.49
Total Kg 633.82
D.1 80 x 4 x 3mm fixed
Total length 434.10
Unit Wt. for the section 5.37
Total Kg 2,330.86
Base plate 200 x 200 x 6mm
Total plate 56.00
7. Finishing work
6.0 Two coats of plastering
Internal HCB wall plastering
to receive gypsum chuck
ddt opening 0.00
External plastering
ddt opening 0.00
Bill No.2 Staff Residence Block
For Ariya kayisa Primary School
Summary of Reinforcement for Sub-structures & Super-Srructure
Foundation Footing
Foundation Column
Ground Floor Beam
Ground Floor Slab
Super-Structure
Elevation Column
REINFORCING BAR SCHEDULE
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Date , Sep 28,2025
Bill No.-2-Staff Residence Block Consultant;- UNOPS-ETMCO
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Foundation Colum --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Foundation Column --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Ground floor slab --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
internal partiton area --- --- --- --- --- --- --- ---
REINFORCING BAR SCHEDULE
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Date , Sep 28,2025
Bill No.-2-Staff Residence Block Consultant;- UNOPS-ETMCO
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Elevation Column --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
United Nations Office for Project Services
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
Tender Reference:
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR),
CONSTRUCTION WORKS FOR VETERNARY PROJECT
BILL OF QUANTITIES (BOQ)
- Bill Nr.1 - Mobilization
- Bill Nr.2 to 10-Civil, Electrical & Sanitary Works-BoQ
- Bill Nr.11 - Day Works
NOTE: It is a MANDATORY requirement for bidders to complete and return both this excel BOQs and their respective duly signed pdf for further reference
Failure to complete all sections of the BOQ may result to automatic disqualification of your bid.
PREAMBLE TO BILLS OF QUANTITIES
1 Priliminary Condition
1.1 This Specification shall be read in conjunction with the Particular Technical Specifications provided under each work discipline, as well as the latest edition of the Sudan Standard Technical Specifications for Building Works, or any other internationally recognized standards commonly adopted in Sudan.
1.2 The Bill of Quantities (BoQ) shall be measured in accordance with the latest edition of the Sudan Standard Methods of Measurement for Building Works.Pro Memoria (PM): Indicates that the cost of the item is deemed to be included and distributed within other related work items in the BoQ. No separate payment will be made.Lump Sum (LS): Indicates that the item is priced as a fixed total amount, with no adjustment or variation permitted to the total price regardless of actual quantities executed.
1.3 The contractor has fully understood the scope of works by minutely having studied the drawings and Bill of Quantities with specifications, and by having visited the site. He will, on his own initiative and before the works start and in his best ability, notify the consultant of works which are not mentioned in the BoQ and/or the specifications and/or the drawings, which are necessary to execute the construction as envisioned in the drawings. Thus, after the works have started, the contractor cannot rely on incompletions in the consultants' work to make claims of any kind. Indeed, the contractor will add upon the specifications according to his own insight and professional experience. If there are works to be done which are not specified in this BoQ, it is up to the consultant to decide wether these works are variation works which need change orders, or wether these works are included in the items and their prices in the BoQ.
1.4 The contractor has to execute all works which have a direct or indirect impact on safety and availability of infrastructure (water, sewage, electricity, …) in as short a period as feasible.
1.5 The contractor will secure the structural and functional integrity of the exsiting buildings nearby the project site during construction work as well as of the building’s surroundings such as but not limited to public road, gate, lawn. He will study and execute the necessary scaffolding to support the building, in order to avoid any cracks, settlements, or crumbling. This scaffolding to support the building during the works are included in the prices given. Debris will be cart away to certified debris places in the area. In no way, debris will be stored, buried or burned on site.
1.6 After the works, the contractor will do a thorough cleaning of the construction site, this means cleaning of all excess mortars, cement bags, excess blockwork, excess tile jointing – in short any construction remnant which hinders the proper use of the house upon site hand-over.
NHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
1.7 In general the contractor will put his professional experience and craftsmanship to work, in order to get a holistically well-constructed building, to the highest and most up-to-date standards of Sudan Construction & international Culture.
2 Organisation of Construction Site
This includes all necessary preparations to execute the works; at least from the beginning until the end of the works; according to the best knowledge and experience of the contractor: at least conform local standards.
The objectives of the Bill of Quantities are
(a) to provide sufficient information on the quantities of Works to be performed to enable bids to be prepared efficiently and accurately; and
(b) when a Contract has been entered into, to provide a priced Bill of Quantities for use in the periodic valuation of Works executed.
In order to attain these objectives, Works have been itemized in the Bill of Quantities in sufficient detail to distinguish between the different classes of Works, or between Works of the same nature carried out in differently or in other circumstances which may give rise to different considerations of cost.
4 The Bills of Quantities for the Works comprise the following:
Preamble to Bill of Quantities
List of principal Quantities
Bill Nr. 1 Mobilization
Bill Nr. 2 - 10 Civil, Electrical Installation & Sanitary Installation
Bill Nr. 11 Day Works
5 The Contractor’s unit rates in these bills are to cover supplying of materials, taking delivery, transporting, loading and off loading inspection, storage, stacking, landing, preparation, installation including provision of all labour, requirement false work, temporary support, surface preparation and testing of the works. The rates shall include all applicable taxes and duty. The cost of testing of the materials to be used in the works unless otherwise provided is to be included in the rates of the respective Bill items.
6 Measurement for payment shall be for the complete installation and having passed all necessary tests.
7 Work shall not be executed on a Day work basis unless ordered in writing by the Consultant on approval by the Employer. The rates entered in the Day works Bill of Quantities shall apply to any quantity of Day work instructed by the Consultant. Nominal quantities have been indicated against each item to permit the extended total to be carried forward to the Grand Summary.
8 “Rates and prices shall be inserted in the rate and total columns of the Bill of Quantities in USD
9 Bills of Quantities are to be read in conjunction with the Instructions to Bidders, the Conditions of Contract Data, the Specifications and the Drawings. The quantities stated against each item in the Bills of Quantities, with the exception of those items specifically marked ‘sum’, are the estimated quantities of the Work to be executed by the Contractor in fulfillment of his obligations under the Contract.
10 The Contractor is required to check the number of the pages and should any be found to be missing or in duplicate he must inform the Engineer at once and have the same rectified.
11 No liability whatever will be admitted or claim allowed in respect of errors in the Contractor’s tender due to mistakes in the Bills of Quantities which should have been rectified in the manner described above.
12 The contractor shall not alter or otherwise qualify the text of these Bills of Quantities. Any alteration or qualification made without authority will be ignored and the text of the Bills of Quantities as printed will be adhered to.
13 Each item in the Bills of Quantities is to be priced. If any items are left un-priced it will be assumed that the value of the work described there under is elsewhere allowed for. The prices and rates to be inserted in the Bills of Quantities are to be fully inclusive of all costs and expenses which may be required for the construction of the work described, together with general risks, liabilities and obligations set forth or implied in these documents.
14 In no case will any claim for expenses incurred by the Contractor in preparation of this Tender be allowed.
15 The Contractor is solely responsible for the accurate ordering of materials in accordance with the Specifications, Drawings and Engineer’s Instructions and no claim for any loss or expense will be entertained for orders for materials based on the Bills of Quantities.
16 The quantities given in the Bills of Quantities are estimated and no claim by the Contractor for the final quantities being larger or smaller than the quantities given in the Bills of Quantities will be permitted except alows in accordance with the particular of the Conditions of Contract.
17 The dimensions given in the Drawings are generally in millimeters unless otherwise indicated. Levels are given in meters.
18 The term ‘provide’ or ‘supply’ used for any item shall be deemed to include transport to site, handling, storage and fixing complete, and the Bidder’s rate shall include for this.
19 The following abbreviations have been used in the Bills of Quantities:-
ml metre linear
m2 square metre
PS provisional Sum
Set Complete set of work with accessories & components
lot Complete set of work with accessories & components
PS provisional Sum
USD United States Dollar
uPVC un-plasticized poly vinyl chloride
HDPE high density polyethylene
GMS galvanized mild steel
PPE personal protective equipment
ASTM American society for testing & material
GW well-graded gravel
GP poorly-graded gravel
GM silty gravel, gravel-sand-silt mixtures
GC Clayey gravels, gravel sand-clay mixtures
SW well graded sands
SP poorly graded sands
SM silty sand, sand -silt-mixtures
SC clayey sands, sand-clay mixtures
AASHO American Association of State Highway and Transportation Officials,
ACI American Concrete Institue
RHS rectangular hollow section
PVD Physical Vapor Deposition
HCB hollow concret block
CBR california bearing ratio
MC medium curing
SDB sub distribution board
PDB pump distrbution board
20 Unless otherwise provided there are no separate measurement items for Contractual requirements. The Contractor is deemed to have included his costs for the Contractual requirement
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
SAWAKIN- VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
GRAND SUMMARY Amount in USD
1 Bill Nr.1 - Mobilization USD 0.00
2 Bill Nr.2 -Model Veternary Building-
2.1 - Civil Work USD 0.00
2.2 - Electrical Installation Work USD 0.00
2.3 -Sanitaryl Installation Work USD 0.00
3 Bill Nr.3 - Solar PV USD 0.00
4 Bill Nr.4 Pump Control Swith Shed with platform-Civil Work USD 0.00
5 Bill Nr.5 Septic Tank & Soak Away Pit-Civil Work USD 0.00
6 Bill Nr.6 Cattle Waste Holding Tank-Civil Work USD 0.00
7 Bill Nr.7 Site Works-Civil USD 0.00
8 Bill Nr.8 Site Work-Electrical USD 0.00
9 Bill Nr.9 Site Work-Sanitary USD 0.00
10 Bill Nr.10 Signage USD 0.00
GRAND TOTAL USD 0.00
11 Bill Nr.11 - Day Works USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
SAWAKIN VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill Nr. 1- Mobilization & Existing Condition
1 SIGN BOARD USD 0.00
2 SITE SUPERVISOR TRANSPORTATION USD 0.00
3 SAFTEY HARNESS & PROTECTION USD 0.00
4 SAFTEY & SECURITY OF WORKS USD 0.00
5 SHOP DRAWINGS USD 0.00
6 Existing Condition/Demolishing Work USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 Contractor to provide a Project Identification sign size (200 cm × 200 cm), Contractor to submit shop drawing for UNOPS Engineer Approval, also 2 safety signs (120 cm x 120 cm). Safety signed to be submitted to approval of Engineers. LS 1.00 0.00
2 Site Supervisor Office & Transportation
2.1 Providing office for supervisor team completed with office Desk LS 1.00 0.00
3 Safety Harness and Protection
3.1 2 No (Minimum) Safety Harness with lanyards , 3 fire powder 6Kg fire extinguishers, and selection of gloves & safety glasses to be kept in UNOPS Office at all time, also contractor should in his price include the cost of providing all his staff and work force with suitable PPEs ( i.e. Hard Hat, Safety Boot, Dust Masks, Safety Vests and Safety Glasses) Ls 1.00 0.00
4 Safety & Security of Works
4.1 Allow for providing safety and security for the Works and material as per the requirement laid under the Contract, including security lighting, lockable or open material storage areas, engaging security guards and / or any other measures as necessary. Cost shall include Road Safety awareness, and public traffic flow management during construction. LS 1.00 0.00
4.2 Providing, erecting, maintaining, and removing temporary site hoarding/fence made of corrugated iron sheets (C.I.S.) securely fixed to eucalyptus posts, including all posts, bracing, fixing materials, excavation, installation, maintenance, dismantling, and disposal upon completion. The hoarding shall be approximately 2.4 m high and installed along the site perimeter adjacent to the public road and other accessible areas, as directed by the Engineer, to prevent unauthorized access and ensure site security. ml 93.00 0.00
5 Shop Drawings
5.1 Allow for prepare and submit to the Engineer's Representative a complete set of Shop Drawings, as required to the specified scale(s), giving all details, as required by the Engineer's Representative, for the work executed. Submission shall be in 3 sets as hard copies, color printed on A1 size paper and 01 set of soft copies in AutoCAD compatible version in a compact disc. LS 1.00 0.00
6 Existing Condition/Demolishing
6.1 Demolishing
The work shall be performed by qualified personnel who have ample experience in demolishing and safety work in order to avoid risk in the existing structure and in human life. Any useful dismantled materials shall be kept in proper manner and submitted to the client after proper cleaning. The contractor shall take all the responsibility of worker discipline in order to avoid disturbance and security issues at the work place and the entire compound. The contractor shall protect the existing area with approved standard plastic or other protective cover. Contractor is advised to investigate the scope of dismantling work before filling in prices.
The rate shall include breaking, cutting, dismantling, loading, hauling and disposal of all demolished materials, debris and unsuitable materials to an approved disposal area designated by the Engineer/Employer, including all labor, tools, plant, equipment, lifting and hauling facilities, water, temporary works, protection of adjacent structures and services, dust suppression, cleaning of the site, and all other incidental works necessary to complete the demolition safely and entirely in accordance with the drawings, specifications and Engineer’s instructions.
The contractor shall take all necessary precautions to prevent damage to adjacent buildings, utilities, pavements and other retained structures. Salvageable materials, if any, shall be separated and handed over to the Employer as directed by the Engineer. The area shall be left safe, clean, level and ready for subsequent construction works. The contractor shall submit methodology and work plan for approval by the Engineer before commencing the Works. contractor is advised to go through the detail of the building structure during pre-bid site visit.
A Demolition and complete removal of the existing wire mesh perimeter fence, comprising RHS steel structural framing with vertical supports spaced at approximately 4.00 m c/c and three (3) horizontal RHS support members between vertical posts. Each vertical support shall be dismantled and removed together with its approximately 400 × 400 × 500 mm reinforced/plain concrete foundation pad, including any embedded steelwork, fixing plates, bolts, ties and associated components. ml 27.00 0.00
6.2 Preparation of the existing dirt road at the interface with the new entrance gate interlocking pavement, including trimming and shaping the existing road edge to a firm and straight profile, removal of loose, soft, or unsuitable soil and debris, thorough cleaning and preparation of the interface, excavation and formation of the required transition area, provision and compaction of suitable subgrade and granular base material, installation of concrete edge restraint and proper connection of the new interlocking pavement to the existing dirt road to form a smooth, stable, and durable transition, all complete as directed by the Engineer. The rate shall include all labor, materials, equipment, excavation, supply and placement of selected fill and base course, watering and compaction, concrete edge restraint, hand tools, protection of adjacent works, trimming and grading, and all incidental works necessary to achieve a proper and durable transition between the existing dirt road and the new interlocking pavement. Ml 4.00 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
SAWAKIN- VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.1- Veternary Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 GLAZING USD 0.00
8 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 294.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 75.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 202.00 0.00
1.4 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 23.00 0.00
1.5 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 126.00 0.00
1.6 Ditto as above item 1.5 but around isolated footing. m3 188.00 0.00
1.7 Ditto as above item 1.5 but around masonry foundation wall. m3 12.00 0.00
1.8 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 391.00 0.00
1.9 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 177.00 0.00
1.10 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 217.00 0.00
1.11 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 104.00 0.00
2.1.2 Under masonry foundation wall m2 47.00 0.00
2.1.3 Under grade beam m2 22.00 0.00
2.1.4 Under slab on grade including ramp & outdoor treatment m2 177.00 0.00
2.1.5 Under masonry steps on grade m2 2.00 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 39.00 0.00
2.2.2 In foundation column. m3 4.00 0.00
2.2.3 In grade beams. m3 15.00 0.00
2.2.4 In 15 cm thick ground floor slab including ramps & outdoor tratment. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 177.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 55.00 0.00
2.3.2 To foundation column m2 45.00 0.00
2.3.3 To grade beams & ramps edge m2 155.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 8 mm deformed bar Kg 17.00 0.00
Dia 10 mm deformed bar Kg 53.00 0.00
Dia 12 mm deformed bar Kg 2,117.00 0.00
Dia 14 mm deformed bar Kg 819.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 244.00 0.00
Dia 14 mm deformed bar Kg 170.00 0.00
Dia 16 mm deformed bar Kg 818.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 327.00 0.00
Dia 14 mm deformed bar Kg 331.00 0.00
Dia 16 mm deformed bar Kg 1,020.00 0.00
2.4.4 For floor slab on grade, ramp slab & outdoor tratment slab
Dia 8 mm deformed bar Kg 648.00 0.00
Dia 10 mm deformed bar Kg 173.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 46.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 2.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 8.60 0.00
1.1.2 In top tie beams m3 10.60 0.00
1.1.3 In water tanker slab with beams m3 1.20 0.00
1.1.4 In lintel beams including roof vent windows m3 0.30 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 91.00 0.00
1.2.2 To top tie beams m2 108.00 0.00
1.2.3 To water tank slab with tie beam m2 9.00 0.00
1.2.4 To lintel beams including for roof vent windows m2 3.00 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 182.00 0.00
Dia 16 mm deformed bar Kg 812.00 0.00
1.3.2 For top tie beam
Dia 8 mm deformed bar Kg 270.00 0.00
Dia 14 mm deformed bar Kg 294.00 0.00
Dia 16 mm deformed bar Kg 1,101.00 0.00
1.3.3 For water tanker slab & beam
Dia 8 mm deformed bar Kg 8.00 0.00
Dia 10 mm deformed bar Kg 100.00 0.00
Dia 16 mm deformed bar Kg 28.00 0.00
1.3.4 For water tanker slab & beam
Dia 6 mm deformed bar Kg 8.00 0.00
Dia 12 mm deformed bar Kg 31.00 0.00
Total carried to summary USD 0.00
Walls shall be constructed from class 'B' hollow concrete block (H.C.B.). The blocks shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the blocks shall be in such a way that good key for plasterer is obtained on both side.
2.1 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. m2 349.00 0.00
2.2 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B), the hollow part shall be fully grouted with cement sand mortar and jointed in cement sand mortar mix (1:3) one side left for appropriate finishing and the other side left for to fix sika joint or fiber board.Price shall include cement sand mortar fill inside hollow part of the wall. For X-ray room back wall m2 62.00 0.00
2.3 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) with vertical & horizontal stiffeners bedded and jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. The stiffening methods and application shall be as per the detail structural dwg. Price shall include stiffening concrete and reinforcement.Price shall also include the recessed decorative wall part showing on the right & left side of the building.-for parapet wall m2 48.00 0.00
2.4 Supply and lay 10 cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. m2 6.00 0.00
2.5 Supply, delivery, preparation, and installation of combined brick layers of ( 20 cm + 10 cm),total 30cm thick red burnet brick wall cladding for internal X-ray room walls surface shown on the Ar. Drawing.The construction must comply with radiation protection requirements and shall be proper sealed with sika or fiber board to prevent radiation leakage. The material physical property shall meet the minimal standard to suit the intended purpose. The installation work shall be as per the architectural detail plan and shall be install from bottom up. The contractor shall submit the material sample. Shop drawing showing fixing details. Installation method and mockup sample shall be constructed for the Architect approval.price shall include 10mm thick SIKA or fiber board joint filler (wall substrate) & bonding bar with HCB wall. m2 62.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 235.00 0.00
3.2 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet ridge hip at the roof slope direction changes. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of ridge cap: 80 cm. m.l. 9.00 0.00
3.3 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 50.00 0.00
3.4 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel vally gutter, supported by the side truss members the work shall include all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 450 mm ml 4.50 0.00
3.5 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet copping at the top roof ridge exposed HCB wall. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of copping: 410 mm. m.l. 24.00 0.00
3.6 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 44.00 0.00
3.7 Supply and fix diam 110mm PVC down pipe. Price shall include 900 elbow connection, PVC liner with all the necessary fixing accessories. ml 52.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors and windows all as per the drawing. All doors should have vertical metal grill 25x25x2mm c/c 15cm for burglar proofing and with 0.5mm thick steel louver at top welded to frames and covered with approved mosquito net. All windows should have RHS 10x10x2mm welded to frames and with steel mesh for burglar proofing. All roof vent should have steel mesh welded on the frame. Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint. (glazing measured separately).
TW-1 size 150 x 85 cm no 2.00 0.00
D-1 size 180 x 255 cm-doble leaf door no 1.00 0.00
D-2 size 90 x 255 cm-single leaf door no 6.00 0.00
D-3 size 85 x 255 cm-single leaf door no 2.00 0.00
4,2 Supply, deliver, install, test, and commission factory made steel-framed, lead-lined radiation shielding X-ray door with vision panel, complete with all accessories and certification. The material shall be Steel door frame and solid core door leaf, factory fabricated, Lead lining to door leaf and frame equivalent to 2.0 mm Pb minimum, Vision panel comprising lead glass with equivalent 2.0 mm Pb shielding, Complete set of heavy-duty ironmongery including hinges, lockset, handles, and door closer, Perimeter sealing with radiation-proof gaskets to prevent leakage, Proper installation including lead overlap at joints and shielding continuity and the work shall include Testing, commissioning, and submission of radiation protection compliance certificate. All are as per the detail door and window schedule and engineers approval.
D-1' size 180 x 255 cm-doble leaf door no 1.00 0.00
D-2' size 90 x 255 cm-single leaf door no 1.00 0.00
4,3 Supply, fabrication, and installation of rectangular roof ventilation unit, overall size 80 cm × 40 cm, consisting of fabricated from 38 mm LTZ-profile, 0.16 cm thick frame. Joints to be welded with 4 mm continuous fillet welds, ground smooth and free of sharp edges. Infill woven wire mesh aperture 1.4 mm × 1.4 mm, wire diameter 0.45 mm, securely fixed to frame by recessed groove or retaining clips. Entire vent unit to be cleaned, degreased, and painted with on coat of anti-rust followed by two coats of metal paint. The color shall be approved by the Engineer and the work shall complete as per drawing. no 8.00 0.00
4.4 Supply, fabricate and fix metal guard rail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 120 × 120 × 6 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 1000 mm above finished floor level; two horizontal balustrade rails CHS Ø20 × 2.5 mm welded to vertical RHS posts; top handrail CHS Ø50 × 2.5 mm welded continuously; infill: vertically spaced CHS Ø20 × 2.5 mm at c/c 100 mm between the two horizontal rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 21.00 0.00
4.5 Supply, fabricate and fix metal ramp handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 15.00 0.00
4.6 Supply, fabricate, deliver, install, and paint steel cattle fence (balustrade type) comprising CHS vertical posts, horizontal rails, and base plates, fixed to concrete floor, complete in all respects. The work shall be Steel fence consisting of Ø100 × 5 mm CHS vertical posts (900 mm height) fixed to concrete using 170 × 170 × 6 mm base plates, spaced at maximum 1000 mm centers, with 4 No. horizontal Ø80 × 2.5 mm CHS rails welded to posts, including all welding, anchoring bolts, alignment, and accessories, finished with anti-rust primer and final metal paint (minimum two coats each), complete as per drawings and Engineer’s approval. ml 14.00 0.00
4.7 Supply and fix elevated water tanker seat metal guard rail all according to size and shape specified on the drawing . Price shall include connection plates, bolt and one coat of primer & two coats of synthetic enamel paint. ml 8.00 0.00
4.8 Ditto as above item and supply, fabricate, deliver,instal and paint steel structure ladder as shown the At. detail drawing. ml 8.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect steel structures using RHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel Structure Column
Steel structure columns are vertical primary load-bearing members, transferring axial loads (and occasionally bending) from trusses to foundations. Since columns are in direct contact with water during cleaning, apply bituminous damp-proof paint at the column base up to a height of 300 mm (30 cm) to prevent corrosion and moisture penetration. price shall damproof paint and stiffening plates as shown in the drawing. for measurment net RHS post will be considered execluding stiffening plates.
A.1 Steel structure column RHS sections of 100 × 100 × 4mm for veranda post. kg 218.00 0.00
B. Steel Structure Column Beam
The beam shall be welded column to column just below the top plate level where truss and column connected. At the end of the beam where there is no steel column. it connected with the building it will be fixed with plate at the concrete column/tie beam
B.1 RHS 80 x 60 x 4mm beam for veranda kg 245.00 0.00
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards. Price shall include gusset plat, connection plate when truss members connect and bolts other than anchor/J-bolt bolts.
C.1 RHS 80 x 80 x 4mm upper & lower truss member for T1, T1' & T2-for T-1' includes vertical member Kg 1,701.00 0.00
C.2 RHS 60 x 60 x 3mm upper & lower truss member for T3, T4 & T5 Kg 434.00 0.00
C.3 RHS 60 x 60 x 4mm diagonal & vertical truss member for T1 & T2 Kg 685.00 0.00
C.4 RHS 50 x 50 x 4mm diagonal & vertical truss member for T3, T4 & T5 Kg 149.00 0.00
D. RHS Purlins 0.00
D.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 100 x 100 x 3mm L= 60mm angle iron. Price include angle iron. Kg 2,145.00 0.00
E. RHS Solar PV Support System 0.00
Supply, fabricate, deliver and install solar panel steel support structure complete with all necessary connection components. The work shall include provision of gusset plates, bolts, nuts, washers, and all fixing accessories required for proper assembly and stability of the structure.The rate shall include surface preparation and application of approved anti-corrosion primer and finishing paint. It shall also include proper sealing and waterproofing treatment where steel members penetrate the roof covering, ensuring no water leakage. All works shall be executed in accordance with approved shop drawings, specifications, and engineer’s instructions.
E.1 RHS 80 x 80 x 4mm steell structure frame member Kg 2,072.00 0.00
E.2 RHS 40 x 40 x 4mm purlin Kg 536.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate for verenda post-size 250 x 250 x 6mm with 4 dia 22 slotted holes. The plated is welded to the RHS post (fillet weld of 3mm throat thickness) and connected to the other plate fixed on concrete column. No 12.00 0.00
A.2 Base plate size 250 x 200 x 6mm with 4 dia 18 slotted holes for truss & ring beam. The plate is welded to the truss (fillet weld of 3mm throat thickness) and connected to ring beam. No 86.00 0.00
A.3 Top plate size 150 x 150 x 8mm for veranda post and RHS beam connection with bolt & nut. No 12.00 0.00
B Bolt with nut
B.1 Base plate/Anchor bolt dia. 16 Length 250mm for truss beam connection and to be weld to ring beam steel reinforcement No 172.00 0.00
B.2 Base plate/Anchor bolt dia. 20 Length 450mm for veranda post No 24.00 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of gypsum finish to internal HCB wall surfaces. m2 535.00 0.00
6.2 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of gypsum finish to internal exposed beam and column surfaces. m2 69.00 0.00
6.3 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive rendering finish to externall HCB wall surfaces. m2 205.00 0.00
6.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final rendering finish to external exposed beam and column surfaces. m2 112.00 0.00
6.5 Prepare the surface and apply final a 3 mm to 5 mm thick final skim coat using a 1:3 cement-to-fine-sand mortar mix. Fine sand must be sieved through a 1.18 mm mesh. The surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks to internal wall, beam & column surfaces. m2 604.00 0.00
6.6 Prepare the surface and apply final apply 15mm thick cement and sand rendering (1:3 mix) for external wall surface. Price includes surface preparation, hacking of concrete surfaces, wire mesh for joints, curing for 7 days. The rendering pattern shall be as per the Architect approval. m2 317.00 0.00
6.7 Prepare the surface, supply and construct 2 cm thick x 25 cm wide polished marble threshold for doors bedded on cement sand mortar 1:3. Price include 30mm thick cement sand mortar backing and white cement grouting. All are as per the detail Ar. Dwg. ml 10.00 0.00
6.8 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 59.00 0.00
6.9 Prepare the surface, supply and fix nominal thickness of 0.85 cm approved standard 60 x 60 cm non-slippery ceramic floor tiles bedded in an average 4.15 cm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 12.00 0.00
6.10 Prepare the surface and apply epoxy resin coating flooring as shown in the drawing- the epoxy flooring shall be suitable type for veternary clinic:- Epoxy floor, shall be applied on the concrete floor or 4.6 cm thick cement sand screed flooring using OPC cement and Rheomix 141 strengthening additive in order to achieve the required bedding strength for animal hoof. The application of the screed shall be leveled and finished with a fine texture screening while the concrete is fresh and it is preferable to hold the proper application of epoxy floor finish with out any additional leveling. screed to the base floor shall be done with proper slope as instructed by the engineer and shall be done as per the advice and follow up of the epoxy supplier in order to assure the bonding between the concrete slab and screed. The contractor should use bonding chemical agent primer that shall be approved by the Engineer. Price shall include screed, Rheomix 141 strengthening additive and epoxy floor finish. m² 38.00 0.00 4800 0 0 4800 #REF! #REF! #REF! #REF! #REF! #REF!
6.11 Prepare the surface and construct belt & brace flooring as shown the detail Ar. Detail drawing. The work shall be 1 x 2 cm slip resistance diamond grooved finish with non metalic dry shake hardner. All are as per the detail drawing, manufacturere instruction and Engineer approval. m² 93.00 0.00
6.12 10cm high 1cm thick chamfered ceramic skirting of matching color to floor tiles. ml 106.00 0.00
6.13 Supply and fix 30 x 60 x 0.85 cm ceramic wall cladding, of matching color to floor, stuck to wall with cement sand mortar 1:3 backing and grouting with white cement wash. Price shall include rod anchors to backing. Size, color and pattern according to architect's drawings. m2 106.00 0.00
6.14 Supply and fix granite stair tread bedded on cement mortar 1:3 price include mortar bed, nosing and chamfering. Color and pattern shall be approved by the Architect.
a) For entrance step-tread
- Tread size: (33 x 3 cm) ml 8.00 0.00
6.15 Ditto as above but riser.
a) For entrance step-rise
- riser size: (13.4 x 2 cm) ml 8.00 0.00
6.16 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick marble window sill. Price shall include cement sand mortar bed and cement grouting. ml 12.00 0.00
6.17 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick marble short wall copping. Price shall include cement sand mortar bed and cement grouting. ml 12.00 0.00
6.18 Supply and fix chamfered, bullnose and water dripped 25 x 3cm thick marble edge trim for veranda edge. Price shall include cement sand mortar bed and cement grouting. ml 21.00 0.00
6.19 Supply and fix approved quality 0.8cm thick chip wood ceiling as per the detail drawing and engineers approval. The batten fixing method with steel truss shall be L-shaped or U-shaped steel brackets welded/bolted to the steel truss members. Battens are then nailed or screwed to the brackets. Price shall include 4 x 5 cm suspensions wooden battens with c/c spacing of 600mm both ways, middle and corner list, nails and all the necessary fixing accessories. m2 105.00 0.00
6.20 10 cm thick Concrete pavement around the building bedded on 10 cm thick red ash or fine aggregate and 20cm thick compacted granular materials. The work shall be mixing, placing, compacting, curing, and finishing of concrete with trowel finish while fresh. Price shall include red ash bed, selected fill and trowel finishing work. m2 90.00 0.00
Total Carried to summary USD 0.00
7.1 Supply and fix 0.5cm thick clear glass. Price shall include all the necessary fixing accessories. m2 15.00 0.00
7.2 Supply and fix 0.5cm thick figured glass. Price shall include all the necessary fixing accessories. m2 6.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
8.1 Apply three coats of plastic emulsion paint to internally gypsum plastered wall surfaces. m2 604.00 0.00
8.3 Ditto as item 8.1, but to chip wood ceiling. m2 105.00 0.00
8.3 Apply final acrylic emulsion paint to external rendered wall surface, exposed R.C columns and beams. m2 317.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
SAWAKIN- VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.2- Veternary Building-Electrical Installation
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
9 ELECTRICAL WORKS
9.1 uPVC Pipes and Ducts
9.1.1 50mm diameter uPVC m 10.00 0.00
9.2 Earth Network (Grounding System)
9.2.1 Grounding pit 500x500x500mm with top cover inscribed "Grounding pit" as per the detail drawing No 1.00 0.00
9.2.2 Under ground termination network with bare copper cnductor of 1x70sq.mm ml 100.05 0.00
9.2.3 Insulated ground connecting copper cable of 1x70sq.mm ml 30.00 0.00
9.2.4 Earthing electrode diameter 20mm and length 3000mm
Note:If the earth resistence is more than 10 ohms
add additional electrode spaced at length of
the electrode (spaced at a minimum of 5m appart) No 5.00 0.00
9.3 DISTRIBUTION BOARDS
9.3.1 Factory assembled and tested surface-mounted main distribution Board, MDB in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting:
1pc main RCBO of 50A, 3ph , Icu=16KA, 30mA.
1pcs MCB of 32A, 3ph , Icu=10KA
2pcs MCB of 20A, 1ph , Icu=10KA
7pcs MCB of 16A, 1ph , Icu=10KA, coupled with RCD of 30mA. 0.00
8pcs MCB of 16A, 1ph , Icu=10KA
4pcs MCB of 10A, 1ph , Icu=10KA
2pcs MCB of 16A, 1ph (spare) Icu=10KA
1Pc of surge arrestor of 40KA
3 pcs current meters of 50/5A with 6A fuse
1 pc Volt meter of 500V with selector switch and 6A fuse
1 pc frequency meter
with 25% reserve space and busbar of 63A/3ph. No 1.00 0.00
9.4. Feeder Cables and PVC pipes
PVC Sheathed PVC Insulated power cable type NYY 0.6/1KV or equivalent to be drawn inside riser shaft or PVC conduit (measured elsewhere, tentative) and of:-
Cable sizes include: 0.00
9.4.2 5x10 mm2 From Inverter to MDB m 5.00 0.00
9.5. Light & Switch Points 0.00
9.5.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 46.00 0.00
9.6. Light Fittings and Lamps 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved.
9.6.L1 LED Panel Light: 600x600mm, 22.5W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 6.00 0.00
9.6.L2 LED Panel Light: 300x1200mm, 27W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 8.00 0.00
9.6.L2E LED Panel Light: 300x1200mm, 27W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free, & ~1000 lumens (emergency), 4000K, 90 minute operation, No 3.00 0.00
9.6.L3 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 11.00 0.00
9.6.L4 LED Batten Light:L600mm, CRI > 80, ceiling-mounted, polycarbonate, IP44, flicker-free. No 2.00 0.00
9.6.L5 LED Slim Downlight: 10W, 1100 lumens, 4000K, CRI > 80, polycarbonate, IP44, 220VAC, driver included, No 8.00 0.00
9.6.L6 Mini LED Wall Pack for Toilet Mirror, 10W, 1000 lumens,4000K, CRI > 80, wall-mounted, polycarbonate, IP65 No 3.00 0.00
9.6.(E) Non-maintained LED emergency light (only activates during power failure). Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). Warranty: 3 years (components), 5 years (battery). No 4.00 0.00
9.6(ODL) Over door light bulk head to indicate occupancy of the xray room No 1.00 0.00
9.6. Socket Points
9.6. 10-16A/1P flush mounted/recessed socket outlets point fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 20.00 0.00
9.9.2 Dito but for Double Outlet No 10.00 0.00
9.7 Power outlet points.
9.7.1. 16A/1P power outlets point for exaust fan and booster pump fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 8.00 0.00
9.7.2 20A/1P power outlets point for split AC fed through PVC insulated conductors of 3x4mm² inside PVC conduits of 19mm inner diameter, including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type-approved. No 2.00 0.00
9.7.3. 32A/3P power outlets point for X-Ray Machine fed through PVC insulated conductors of 5x6 mm² inside PVC conduits of 32mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 1.00 0.00
9.7. Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard.
9.7. Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete.
9.7.1 Single Pole 1-Way Switch No 6.00 0.00
9.7.2 Double pole Switch No 6.00 0.00
9.7.3 Two Way Switch No 6.00 0.00
9.7.4 Two Way Switch Weather proof for outdoor installation No 2.00 0.00
9.7.4 Intermidiate Switch Weather proof for outdoor installation No 1.00 0.00
9.8. Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00
9.8.1 16A ,1ph ,220V 2p+e socket out let No 20.00 0.00
9.8.2 Dito but Double (Twin) Outlet No 10.00 0.00
9.9 Lightning Arrester System
(Eritech or Equivalent)
Shall include all metalic structures in the network with appropriate welding (ventpipes,ducts ,GIS roof & structures, solar PV panels, e.t.c)
9.9.1 Early Streamer Emmision(ESE) Protector SI 25 with mounting mast of H=3.0m and all necessary connecting acessories. No 1.00 0.00
9.9.2 25x3mm copper tape with all necessary roof connecting accessories m 90.00 0.00
9.9.3 25 x 3mm insulated copper tape with vertical supportings every 1m to the wall & all the necessary accessories coordinate the routing of down conductors with the building external skin and architectural features. ml 40.00 0.00
9.9.4 Lightening Event counter to be installed on the down conductor to count number of lightening strikes. No 2.00 0.00
9.9.5 Test point (junction box) with all necessary connection acessories to connect the down conduction with the earthing bare copper wire. at least 1.5m above floor finish. No 2.00 0.00
9.9.6 Prefabricated Crowsfeet 25x3mm tinned coper tape. In complienc with IEC-EN 62561-2, with L1=1000mm and L2= 3000mm No 2.00 0.00
9.9.7 50 x 50 x 50 cm test pit with top cover inscribed "Test pit" as per the detail drawing No 5.00 0.00
9.9.8 1 x 70 sq.mm bare copper wire. ml 10.00 0.00
9.9.9 Diameter 20mm & 3000mm long copper rod. No 2.00 0.00
9.10 DATA\ Telecome System
Tel/Data according to manufacturer’s and utility supplier’s requirements, supplied, installed, connected color coded including tags and tested, complete, all as specified and / or as shown on the drawings
Structured Cabling
Horizontal CAT6A Cabling
9.10.2 Tel/Data and Data/Data points fed through 2x(twisted pair category 6A UTP cable) inside FRLS PVC conduits of 20mm diameter and thickness not less than 1.5mm with conduits accessories (coupling, junction boxes) for tele/Data outlet socket. No 11.00 0.00
9.10.3 Cat 6A 24 port Patch Panel RJ 45 contact No 2.00 0.00
9.10.4 Cat 6A RJ 45 Patch Cord 0.5m, from switch to pantch panels No 48.00 0.00
9.10.5 Cat 6A RJ 45 Patch Cord 3m, from outlets to workstation computers. No 11.00 0.00
Equipment Racking
9.10.6 Wall Mount metallic rack of 15U pivoting cabinet swing 19" steel enclosure with transparent and lockable door, Built-in PDUs (8-10 Outlets, Grounded) and cooling fans. No 1.00 0.00
9.10.7 1U Horizontal Cable Management Bars, 5 Vertical Plastic Hoops with Cover No 3.00 0.00
Information Outlets: Data &Voice
Extra Over Data Socket Outlets with Detachable Frames & Corresponding Box
9.10.8 2 x RJ45 8 Contact CAT6a Socket Outlets No 11.00 0.00
Active components Type CISCO or approved equivalent.
9.10.10 48-port Gigabit Data +2x10G uplink Switch . No 1.00 0.00
9.10.15 Hybrid PBX with 24Analog, with 4 trunk, Extension including Operator Phone No 1.00 0.00
9.10.16 Cat 6A RJ 11 Patch Cord 1m No 24.00 0.00
9.11 FIRE ALARM SYSTEM
9.11.1 Convensional Fire alarm Control Panel, 2 zones Complete with power supply & battery backup. No 1.00 0.00
9.11.2 smoke detector; with Flash Scan and Detector Base, Complete No 10.00 0.00
9.11.4 Fire alarm sounder strobe (RED) No 2.00 0.00
9.11.5 Surface mounted manual break glass push button including back box No 2.00 0.00
9.11.6 Flush Mounted Fire Alarm Points fed in 2 x 1.5sq. mm Fire Alarm cable (SLC-detectors) inside FRLS PVC conduits of 16mm diameter and thickness not less than 1.5mm with conduits accessories (coupling, junction boxes) No 14.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
SAWAKIN- VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.3- Veternary Building-Sanitary Installation
CLINIC BLOCK SANITARY WORKS
1.1 SANITARY EQUIPMENET ( FIXTURES ) USD 0.00
1.2 Water Supply Pipes and Valves USD 0.00
1.3 Waste Pipes and Accessories USD 0.00
1.4 HVAC System USD 0.00
1.5 Fire Fighting System USD 0.00
Total Veternary Clinic Building-Sanitary Installation USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 SANITARY EQUIPMENET ( FIXTURES )
All fixtures which are specified below is subject to the owner's / consultant's approval, based on samples, catalogues and brochures presented by the contractor. Unit price shall include all the necessary fixing brackets or hooks and all assistance civil works such as chiseling of walls, floors, beams and etc.
1.1.1 HAND WASH BASIN (ORDINARY)
Supply and fix R.A.K. or Equivalent, hand wash basins made of white glazed vitreious china with REMER/JAQUAR or Equivalent chrome plated cold water tap, pedastal stand ,complete with stop & arrest valves on water inlet pipe. mixing battery plug, chrome plated chain holder, P-smell trap with connection pipe, fittings, all other necessary etc.complete in all respects. Flexible hose to be REMER or Equivalent and should be capable of resisting pressure of 4 bar. P-smell trap should be brass chrome plated with 50mm height of water seal and trap. № 1.00 0.00
a) Size :- length X width (1000mm x 435mm)
1.1.2 Ditto No 1.1.1 but for animal health clinic medical laboratory and surgical purpose each with two bowl. № 2.00 0.00
1.1.3 Ditto No 1.1.1 but for cleaner room № 1.00 0.00
WATER CLOSET (ORDINARY)
1.1.4 Supply and fix wash-down action toilet squatting pans made of white vitreous china, complete with high-level flush cistern, vertical flush pipe connecting the cistern to the squatting pan, and all necessary accessories. The price shall include stop and arrest valves before water inlet; cistern of vitreous china with a capacity of 7 to 9 liters and maximum filling time of 2 minutes, complete with heavy-duty float valve suitable for water pressure up to 4 bar; chrome-plated steel flush valve; heavy-duty flexible pipes rated for a working pressure of 4 bar; and vertical flush pipe of durable corrosion-resistant material (e.g., galvanized steel, stainless steel, or UPVC) connecting the cistern outlet to the pan inlet, complete with necessary bends, brackets, and wall fixings. Where specified, a hygienic flush/bidet connection shall be provided, comprising a flexible hose, handheld spray nozzle, wall bracket, and appropriate isolating valve. № 2.00 0.00
SANITARY WARES FOR PERSONS WITH DISABILITY (PWD)
1.1.5 Supply and install complete set of sanitary wares for physically challenged toilet room fixtures and accessories including: *Vitreous china wc seat with brass or stainless steel hingedheavy duty plastic cover*Vitreous china hand wash basin with lever action faucet with mixer, brass or chrome smell traps and accessories * 6 liters capacity vitreous china cistern with long lever action flushing arm * 5 pieces of stainless steel grab rails (600x35mm) with slip resistant grip and concealed fixings* Blue Folding rails 850mm,760x305mm flush bends,cloth hooks * Stainless steel lever action hinged drop down rail * Color contrasted padded backrest * Automatic hand dryer * Soap Dispenser * Paper Towel Dispenser * Toilet Tissue Dispenser * Alarm Rest Button * Stainless steel Mirror 1000*400mm & all the necessary material to make the toilet functional. The sanitary ware set shall satisfy BS 8300-2 and BS EN 12182. № 1.00 0.00
1.1.6 WET ROOM ACCESSORIES
1.1.6.1 Supply and fix soap holder in white vitreous china of size 150 x 150 mm. Complete with the necessary fixing and other accessories. № 3.00 0.00
1.1.6.2 Supply and fix toilet paper holder from chrome plated brass wall flanged roll with chrome plated fastening screws and other accessories. № 2.00 0.00
1.1.6.3 Supply and fix crystal glass mirrors for toilets hand wash basins for changing rooms and private rooms with copper back protection, including chrome plated brass mirror clips with chrome plated screws and all the necessaary accessories. a) size 500 X 400 mm № 3.00 0.00
1.1.6.4 Supply, fix, test and commission floor drains made of polished steel, complete with P-smell trap /minimum seal depth 75mm/ and all other necessary fittings and accessories. № 4.00 0.00
Total carried to summary USD 0.00
1.2 Water Supply Pipes and Valves
Domestic water pipes shall be in PPR- PN 4 & be fixed to walls, beams or etc… with metal/ compatible straps. Unit price shall include all assistance civil works and necessary fittings such T, bends, Y, reducers Unions and other necessary valves shall be fixed properly as per the manufacturer's instruction and according to where shown on the drawing. Hot water supply shall be properly insulated and external PPR pipe has to be coated All water pipes shall be tested two times the working pressure or 100 meters head, which ever is greater at the expense of the contractor.
1.2.1 Supply and install PPR PN-4 pipes to internal domestic water distribution system pipes as where shown on the drawing. And external pipes shall be coated Complete with all the necessary fittings and accessories. The pipe shall be coated when applied on exposed surfaces
1.2.2 Supply and fix chrome service valves of approved standard before hand wash basins, water closets and other fixtures. Complete with unions, elastic water proofing, hand wheels of normal quality and with all other necessary accessories.
1.2.3 Ditto to item number 1.2.2 approved quality bronze gate valves on internal branch water pipes and pipe inlet to building of the following size and as where shown on the drawing
1.2.4 Supply, Installation, Testing, and Commissioning of Wall/Window Mounted Exhaust Fan: Fan Unit: The exhaust fan shall be a wall or window mounted type, specifically designed for bathroom/ toilet ventilation. Performance: Airflow Capacity: Minimum free air delivery of 200 cubic meters per hour (m³/hr) at 25 Pa static pressure. Sound Level: The maximum sound power level (Lw) shall not exceed 35 dB(A) when measured in accordance with relevant standards. Components & Accessories: The unit shall be complete with all necessary accessories for effective operation, including but not limited to: Multi-speed controller. Integral back-draft shutter. External rain guard/weather louvre. Grille or front cover. All required fixings, gaskets, and seals. Scope of Work: The unit rate shall be inclusive of, but not limited to, the following activities: Supply of the exhaust fan and all specified accessories. Necessary civil works to create or make good the opening, including sealing and making the installation weatherproof. Electrical wiring from the nearest power source, including a dedicated isolation switch, as per electrical codes. Final installation, testing, and commissioning of the system to ensure optimal performance. № 2.00 0.00
Total carried to summary USD 0.00
1.3 Waste & vent Pipes and Accessories
All domestic waste water pipe lines shall be uPVC (PN10) pipes and shall be provided with a minimum slope of 2% towards the outlet. All uPVC pipes and necessary fittings shall be standard quality and be free from damage during storage, construction and etc. Unit price shall include all the necessary assistance civil works, such as excavation cartaway, fixing or hanging to walls, beams or slabs.etc., necessary fittings such as bends, Y, T, etc.
1.3.1 Supply and lay internal uPVC waste according to where shown on the drawings. Complete with all the necessary fittings.
Dia. 50 mm ml 4.00 0.00
1.3.2 Ditto No 1.3.1 for vent pipes with appropriate end cap
1.3.3 FCO(FLOOR CLEAN OUT)
Supply and fix approved quality screw type under slab Clean Out on waste water as where shown on the drawing. Price shall include all the necessary
1.3.4 Animal waste open dith with galvanized steel grate for cattles out door treatment area ml 4.00 0.00
DITCH-: SIZE[mmXmm] = 300 X 300
1.3.5 Dito 1.3.4 but for animal health clinic cattles recovery room treatment area ml 4.00 0.00
DITCH-: SIZE[mmXmm] = 300 X 300
1.3.6 Dito 1.3.4 but for animal health clinic treatment room & X ray rooms.
DITCH-: SIZE[mmXmm] = 300 X 300 ml 8.00 0.00
Total carried to summary USD 0.00
1.40 HVAC System
Supply, installation, testing, and commissioning of HVAC and mechanical ventilation systems for four (4) distinct room types considering high ambient operation temperature of 52 ºC.The items shall be Anti-corrosion treatment for coastal sites, refrigerant pre-charged for up to 15m piping length, Service valves with Schrader ports. The scope of the work include power cabling work from power point to HVAC equipment.
1.4.1 Supply, install, test and commission a complete high ambient split-type air conditioning unit of 1.5 TR (5.3 kW cooling capacity, equivalent to 18,000 BTU/h). The unit shall be inverter type, utilizing R32 or R410A refrigerant (R22 is strictly prohibited), and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 1.3 kW. The system is designed for cooling only and shall be factory-rated for continuous operation in high ambient temperatures up to 52°C. The system shall consist of one (1) wall-mounted indoor evaporator unit and one (1) outdoor condensing unit, complete with all interconnecting refrigerant piping, control wiring, condensate drain line, remote control handset, and all necessary accessories for a complete and functional installation. Indoor Unit (Evaporator): The indoor unit shall be constructed of UV-stabilized ABS plastic with a white finish. It shall include automatic horizontal and vertical swing louvers, a washable antimicrobial pre-filter, and a cross-flow fan designed for silent operation.
Outdoor Unit (Condenser): The outdoor unit shall be an inverter-driven condensing unit with digital inverter (variable speed) compressor, specifically rated for high ambient operation. The unit shall include corrosion-resistant condenser coil and fan motor. Refrigerant Piping: Interconnecting refrigerant piping shall be provided for a distance of not less than 15 meters (49 feet) between the indoor and outdoor units. The piping shall consist of seamless copper tubing, with liquid line of 6.35 mm (1/4 inch) OD and suction line of 12.7 mm (1/2 inch) OD. The suction line shall be insulated with 13 mm (0.5 inch) thick closed-cell elastomeric foam. Control and Operation: The system shall include a wireless infrared remote control handset enabling full functionality. Features shall include LED display with temperature readout, sleep mode, turbo cooling mode, on/off timer (1-24 hours), auto restart after power failure, and self-diagnostic fault code display. Electrical Characteristics: The unit shall have rated load amps (RLA) of approximately 6.0 A, minimum circuit ampacity (MCA) of 8.0 A, and maximum overcurrent protection (MOP) of 15 A. All electrical components shall be rated for 230V / 50Hz supply. Condensate Drain: The unit shall include a condensate drain line of 25 mm (1 inch) nominal diameter PVC pipe, properly trapped and sloped at minimum 1:100 gradient to designated drainage point. Compliance: The equipment shall satisfy conformity with European health and safety standards (IEC 60335-2-40) or equivalent international certification acceptable in Sudan. The Contractor shall submit manufacturer cut sheets and conformity certificates for engineer's approval prior to procurement. Acceptable Brands: Gree, Midea, LG, Carrier, Daikin, or approved equivalent. № 1.00 0.00
1.4.2 Supply, install, test and commission a complete wall-mounted, high ambient exhaust fan for the X-Ray room, designed to provide mechanical extraction of air while maintaining negative pressure and preventing radiation leakage. The fan shall be mounted directly on the exterior wall face over a specially constructed shielded labyrinth penetration through the brick wall. No external ductwork shall be required. The fan shall be centrifugal or axial type,The fan shall deliver a minimum airflow of 150 m³/h (approximately 90 CFM) at static pressure of 100 Pa (10 mmH₂O or 0.4 inches w.g.) rated for continuous operation in high ambient temperatures, and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 0.08 kW (80 Watts) . The system is designed for exhaust-only ventilation (no supply fan) and shall be installed in conjunction with a passive labyrinth intake for fresh air. The system shall consist of one (1) wall-mounted exhaust fan (maximum power: 0.08 kW), one (1) shielded labyrinth penetration constructed through the brick wall, one (1) interior exhaust grille (high-level mounted), one (1) exterior weatherproof louver, one (1) backdraft damper, and all necessary accessories for a complete and functional installation. No ductwork (rigid or flexible) is required between the fan and the room. The Contractor shall construct a shielded labyrinth penetration of "S" or "Z" configuration (offset path) through the 450 mm thick wall. No straight line of sight shall exist from the interior of the X-Ray room to the exterior fan housing or to the outside environment. № 1.00 0.00
1.4.3 Ditto No 1.4.1 but for laboratory room and with cooling capacity of 2.0 TR (7.0 kW cooling capacity, equivalent to 24,000 BTU/h) and maximum power input of 1.80 kW (1,800 Watts) . № 1.00 0.00
1.4.4 Supply, install, test and commission a wall-mounted fresh air supply fan for the Laboratory Room, designed to provide forced filtered(with MERV 8 filter (replaceable type) to filter incoming outdoor air) outdoor air to meet the ventilation requirement. The fan shall be mounted directly on an exterior wall or window, requiring no ductwork. The fan shall be rated for continuous operation in high ambient temperatures up to 52°C, and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 0.1 kW (100 Watts) . Performance Characteristics: The fan shall deliver a minimum airflow of 200 m³/h (approximately 120 CFM) at static pressure of 50 Pa (5 mmH₂O or 0.2 inches w.g.) – lower static pressure is acceptable because no ductwork is attached. Construction: The fan shall be of wall-mounted type, suitable for through-wall or through-window installation. The fan casing shall be constructed of UV-stabilized ABS or galvanized steel with corrosion-resistant coating. The motor shall be sealed type, IP44 minimum (or IP54 for exterior exposure). The fan shall include: Integral backdraft damper (gravity-operated) to prevent reverse airflow when fan is off, Integral insect screen on exterior side,Exterior weatherproof louver (may be integral or separate),Interior grille (may be integral or separate) with manual damper for airflow adjustment, Mounting: The fan shall be mounted on a wall or window frame on one side of the room (e.g., the 4.8 m wall). A circular or rectangular hole shall be cut through the wall or window frame to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. The fan shall be installed level and plumb. № 1.00 0.00
1.4.5 Ditto No 1.4.4 but for exhaust air system designed to maintain negative pressure and remove airborne contaminants from laboratory room and shall deliver a minimum airflow of 500 m³/h (approximately 300 CFM) at static pressure of 50 Pa (5 mmH₂O or 0.2 inches w.g.) – lower static pressure is acceptable because no ductwork is attached. The fan shall consume maximum 0.1 kW (100 W) . Low-Level Mounting: For effective removal of heavier-than-air contaminants (e.g., chemical vapors, dust), the exhaust fan should be mounted low on the wall, approximately 200 mm to 500 mm above finished floor level. The Contractor shall confirm the mounting height with the Engineer prior to installation. Mounting: The fan shall be mounted on the wall opposite the supply fan (e.g., on the opposite 4.8 m wall). A circular or rectangular hole shall be cut through the wall to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. The fan shall be installed level and plumb. № 1.00 0.00
1.4.6 Ditto No 1.4.4 but for tretment room and shall deliver a minimum airflow of 900 m³/h (approximately 530 CFM) at static pressure of 50 Pa (5 mmH₂O), while consuming maximum 0.37 kW (370 W) . № 1.00 0.00
1.4.7 Ditto No 1.4.5 but for tretment room and shall deliver a minimum airflow of 150 m³/h (approximately 90 CFM) at static pressure of 50 Pa (5 mmH₂O), while consuming maximum 0.08 kW (80 W . The fan shall be mounted on the wall opposite the supply fan to achieve cross-ventilation. The fan may be mounted at mid-height (1.5 m AFF) or high level. A circular or rectangular hole shall be cut through the wall to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. № 1.00 0.00
1.4.8 Ditto No 1.4.5 but for a complete exhaust-only ventilation system for the Animal Clinic Isolation Room, designed to deliver a minimum airflow of 1,000 m³/h (approximately 590 CFM) at static pressure of 150 Pa (15 mmH₂O), while consuming maximum 0.2 kW (200 W) maintain negative pressure for containment of airborne pathogens.The fan shall be mounted directly on an exterior wall, requiring no ductwork (or minimal ductwork for distribution). The fan shall be rated for continuous 24/7 operation, and shall operate on a single-phase 230V / 50Hz power supply. № 1.00 0.00
1.4.9 Ditto No 1.4.1 but for electric/battery room and with cooling capacity of 0.85 TR (2.5 kW cooling capacity, equivalent to 8530.36 BTU/h) and maximum power input of 0.60 kW (600 Watts) . № 1.00 0.00
1.4.10 Ditto No 1.4.5 but for a complete exhaust-only ventilation system for the toilet cubicles, designed to deliver a maximum airflow of 300 m³/h (approximately 176.57 CFM) at static pressure of 60 Pa (0.45 mmH₂O), while consuming maximum 0.06 kW (60 W) maintain negative pressure for containment of airborne pathogens.The fan shall be mounted directly on an exterior wall, requiring no ductwork (or minimal ductwork for distribution). The fan shall be rated for continuous 24/7 operation, and shall operate on a single-phase 230V / 50Hz power supply. № 2.00 0.00
1.4.11 Ditto No 1.4.10 but for janitory room. № 1.00 0.00
Total carried to summary USD 0.00
1.50 FIR FIGHTING SYSTEM
4.10 Supply and fix 5kg of ABC type fire extinguisher with metal protection cover as per shown location on the drawing. № 6.00 0.00
4.20 Ditto ( 4.1) but CO2 type for solar electrical control room № 1.00 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
SAWAKIN- VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.3 Solar PV Installation
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
Supply, install, test, and commission a roof-mounted solar photovoltaic (PV) system with a total installed capacity of 22.78kWp, complete with battery storage and a three-phase inverter, designed for reliable off-grid operation. The system shall be engineered for a minimum service life of 20 years, and shall include all required components, accessories, protections, and ancillary works necessary to deliver a fully functional and complete installation, consisting of the following:
1 PV Modules Type Longi solar or approved Equivalent
Monocrystalline bifacial module, 670 Wp, efficiency ≈24.8%, Voc ≈54.6 V, Vmpp ≈45.27 V, IEC 61215/61730 certified. 2 rows × 16 modules roof-mounted; Tier-1 quality and high reliability. Type Longi solar or approved Equivalent. No 34.00 0.00
3 Hybrid Inverter Type Huawei or approved equivalent
3-phase hybrid inverter, 25kW output, 2 MPPT (200–1000 V DC), efficiency ≥ 98.4 %. Integrated battery interface & smart monitoring. No 1.00 0.00
4 Battery System, Type Huawei or approved equivalent
Lithium Iron Phosphate (LFP) stack 15 kWh nominal (14.25kWh usable), 600 V DC nominal range (600–980 V) for 3Ph system. Safe chemistry >4000 cycles. stacks 2.00 0.00
5 Battery Control Modules (PCM)
Power Control Module per stack, manages communication and charge/discharge interface to the hybrid inverter. pcs 2.00 0.00
6 DC protection panel
IP65, 1000V DC protection panel (PV Rated) with busbar ≥ array Isc , 63A, earthing terminal, and all associated accessories consisting of:
2pc DC-rated MCB of 25A
2pc DC-rated String isolator of 32A
1pc, PV rated DC SPD, Type II, In ≥ 20KA pcs 1.00 0.00
All components shall be rated for a minimum of 1000 VDC and suitable for photovoltaic applications. pcs 1.00 0.00
7 DC & AC Cabling
Cu XLPE cables rated 1 kV DC/AC; Includes MC4 connectors, lugs, glands, and labels. ≤ 1.5 % V-drop. 0.00
7.1 1x 4mm2 1kv/DC cables, for PV string connection. ml 60.00
7.2 2x 6mm2 1kv/DC cables, PV string, and from DC protection Panel to Hybrid inverter. ml 10.00 0.00
7.3 2x 10mm2 1kv/DC cables from Hybrid inverter to Battery stacks. ml 10.00 0.00
7.4 5x 10mm2 0.6/1kv AC cables from Hybrid inverter(HIN) to MDB ml 10.00 0.00
8 Monitoring & Communication
Smart Dongle / Gateway (Wi-Fi or Ethernet). Real-time data, alarms, remote monitoring and system analytics. Type Huawei FusionSolar or approved equivalent. set 1.00 0.00
9 Earthing & Lightning Protection
The Solar PV strings shall be bonded to the Early Streamer Emission (ESE) lightning protection roof network using 25 × 3 mm copper tape to ensure effective lightning protection. The PV array structure shall also be bonded to the main earthing network through 70 mm² copper earthing cables, bonding bars, and lightning down conductors. The overall earthing system shall achieve an earth resistance not exceeding 5 Ω. LS 1.00 0.00
10 Installation, Testing & Commissioning
Complete installation of PV array, battery, inverter, wiring, earthing. Includes polarity, insulation, I-V curve, and BMS integration tests, training & handover. LS 1.00 0.00
11 Contingency / Miscellaneous
Spare connectors, cable glands, fasteners, transport, minor site materials. Covers unforeseen adjustments during installation. LS 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
SAWAKIN- VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.4-Water Reservior Plat form & Pump Control Switch Room-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A 0.00
B. SUPER-STRUCTURE
1 BLOCK WORK USD 0.00
2 ROOFING USD 0.00
3 METAL WORK USD 0.00
4 STEEL STRUCTURE USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No additional allowance for working space to be considered for measurement. The site clearing area shall be the net built-up area including aprons, open ditch, entrance step and ramp. m2 10.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for the ground floor from the Average Natural Ground Floor Level (A.N.G.F.L.) to a depth not exceeding 150 cm. The volume of excavation shall be measured only over the net built-up area of the building footprint, excluding aprons, open ditches, and ramps. Working allowance: An additional 0.50 m width on each side of the excavation shall be included to allow for proper working space. Reference level (A.N.G.F.L.): The A.N.G.F.L. is defined as the average of the topographic ground levels taken at the building footprint prior to any excavation works, reduced by 20 cm to account for above work item site clearing. m3 3.50 0.00
1.3 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level. Note: measurement shall include 150 cm working space in each side for trench excavation. m3 3.10 0.00
1.4 Back fill under hard core and around the building with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 3.00 0.00
1.5 Back fill around masonry wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 2.00 0.00
1.6 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material. Disposal shall be measured as the net volume arising from the void created by the excavation, less excavated material backfill, filled and wheel spread within site or left stockpiled. m3 8.60 0.00
1.7 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone.only under concrete channel. m2 1.50 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately.
2.1 5 cm thick lean concrete in grade/class C-5 concrete, minimum cement content of 150 kg/m3 :
A. Under ground floor slab m2 6.00 0.00
B. Under masonry foundation wall m2 5.40 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
A. In 20 cm thick slab m2 6.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
To slab edge m2 2.20 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
A. For slab on grade
Dia 10 mm deformed bar Kg 74.04 0.00
Total carried to summary USD 0.00
3.1 50 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 4.28 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
Walls shall be constructed from class 'B' hollow concrete block (H.C.B.). The blocks shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the blocks shall be in such a way that good key for plasterer is obtained on both side.
1.1 Supply and lay 20cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for pointing.Price shall include recessed pointing. m2 9.12 0.00
Total carried to summary USD 0.00
1.1 Supply and fix approved standard pre-painted 0.35mm thick corrugated iron sheet (C.I.S.) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). m2 4.62 0.00
Total carried to summary USD 0.00
3.1 Double-leaf metal door constructed from 40×40×3 mm RHS steel for vertical and horizontal framing, fully welded and braced with similar RHS sections as shown in the Architectural drawings. Door to be infilled with galvanized steel wire mesh 2.5 mm dia. at 25 mm c/c, welded to frame. Include all necessary welding, surface preparation, one coat of primer, and two coats of synthetic enamel paint to all steel surfaces. All work to conform to detailed drawings and relevant standards.
A. Door D1 size 170 x 150 cm. no 1.00 0.00
3.2 Wire mesh covering for pump control switch side walls made of galvanized steel wire mesh 2.5 mm diameter, spaced at 25 mm c/c, fixed securely to RHS structural frame using appropriate clamps or welding as shown on the drawings. The work includes cutting, fitting, welding (where required), surface preparation, one coat of metal primer, and two coats of synthetic enamel paint on all steel members. All materials and workmanship shall comply with the relevant standards and detailed drawings. m2 2.00 0.00
Total carried to summary USD 0.00
4 STEEL STRUCTURE
4.1 Supply, fabricate, assemble, and erect steel structures using RHS and CHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel Structure Column
Steel structure columns are vertical primary load-bearing members, transferring axial loads (and occasionally bending) from trusses to foundations. Since columns are in direct contact with water during cleaning, apply bituminous damp-proof paint at the column base up to a height of 300 mm (30 cm) to prevent corrosion and moisture penetration.
A.1 steel structure column using two RHS sections, 60 × 60 × 3 mm. not welded part single unit. ml 6.90 0.00
B. Steel Structure Column Beam
The beam shall be welded column to column just below the top plate level where truss and column connected. At the end of the beam where there is no steel column. it connected with the existing building it will be fixed with plate at the concrete column/tie beam
B.1 RHS 60 x 60 x 3mm beam ml 6.00 0.00
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards.
C.1 RHS 80 x 60 x 3mm rafter ml 4.00 0.00
D. RHS Purlins 0.00
D.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 100 x 40 x 3mm L= 60mm angle iron. Price include angle iron. ml 5.70 0.00
4.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate size 150 x 150 x 8mm with 4 dia.18 slotted holes for dia. 16 J-bolt No 8.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
SAWAKIN- VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.5-Septic Tank & Soak Away Pit-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. Price shall include all working space allowances deemed necessary. m2 25.00 0.00
1.2 Bulk excavation in ordinary soil to a depth not exceeding 150 cm starting from the natural ground level. Note: measurement shall include 25 cm working space for bulk excavation. m3 69.00 0.00
1.3 Ditto but from 150 cm to 300 cm m3 41.00 0.00
1.4 Back fill around retaining wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 27.00 0.00
1.5 Spread coars gravel at the bottom of soak away m3 1.41 0.00
1.6 Ditto as above but spread fine gravel fill between coarse gravel and 0.4 cm average sand fill. m3 0.35 0.00
1.7 Ditto as above but spread 0.4cm average sand fill between fine gravel & 0.2cm diameter fine sand. m3 0.35 0.00
1.8 Ditto as above but spread top layer soak away 0.2cm average fine sand fill. m3 0.55 0.00
1.9 Cart away excavated material from the site as approved by the Engineer. Soil shall be damped more than 1km. m3 115.00 0.00
1.10 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
A) The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube moulds necessary for the purpose and for submitting reports of the tests to the Engineer.
B) Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/ class C-5 concrete, minimum cement content of 150 kg/m3 :
2.1.1 Under septic tank bottom slab m2 13.00 0.00
2.1.2 Unde soak away pit m2 7.60 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In 20 cm thick septic tank bottom slab m2 13.00 0.00
2.2.2 In 20 cm thick septic tank top slab including ring beam m2 10.00 0.00
2.2.3 In 15 cm thick soak away top slab m2 5.00 0.00
2.3 Formwork shall be timbered or steel or a combination of two, sufficient to contain the wet concrete without leakage. Enough to support temporary loading and pressure from placing Compaction or vibration without displacement or appreciable deflection.
2.3.1 To septic tank bottom slab m2 3.20 0.00
2.3.2 To septic tank top slab including ring beam m2 7.00 0.00
2.3.4 To k top slab including ring beam m2 3.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 Bottom Slab
A. Diam 12mm Deformed bar. kg 214.00 0.00
A. Diam 12mm Deformed bar. kg 147.00 0.00
2.4.3 Tie submerged beam
A. Diam 10mm Deformed bar. kg 77.00 0.00
B. Diam 8mm Deformed bar for distribution bar kg 45.00 0.00
2.4.4 Soak away top slab
A. Diam 12mm Deformed bar. kg 75.00 0.00
B. Diam 8mm Deformed bar for distribution bar kg 31.00 0.00
2.10 Allow lump sum amount 60 x 60 cm concrete manhole cover Ls 2.00 0.00
2.11 Supply & fix wooden or equivalent 6,, thick wooden baffle as shown the detail drawing and Engineer’s approval Ls 1.00 0.00
Total carried to summary USD 0.00
3.1 Construct average 60 cm at bottom up to 120 cm & 50 cm thick width thick Basaltic or equivalent stone masonry septic tank retaining foundation wall bedded in cement sand mortar (1:4) below NGL. For septic wall. m3 15.00 0.00
3.2 Ditto as above but 50 cm thick masonry wall for soak away pit m3 9.00 0.00
3.3 Septic tank chamber partition:-Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) with stiffeners bedded and jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. Price shall include plastering m2 2.00 0.00
3.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to internal & external masonry wall surfaces. m2 52.00 0.00
3.5 Ditto as above item but for HCB chamber partition wall. m2 4.00 0.00
3.6 Allow lumps amount of sanitary uPVC work for septic tank inlet, chamber partition and out let pipes to soak away pit. ls 1.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
SAWAKIN- VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.6-Cattle Waste Holding Tank
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including 25 cm thick working allowance in each side. m2 21.90 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to an average depth of 150 cm. Note: measurement shall include the net area of the site clearing work. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. m3 32.85 0.00
1.3 Ditto as above item but to a depth above 150 cm but not exceeding 300 cm from reduced ground level. m3 18.61 0.00
1.4 Selected borrow fill around retaining wall with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 24.24 0.00
1.5 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 55.85 0.00
1.6 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described. All works shall be as per the structural general note.
2.1 5 cm thick lean concrete in grade/class C-5, minimum cement content of 150 kg/m3 :
2.1.1 Under bottom holding tank m2 17.00 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In 30 cm thick bottom slab m2 17.00 0.00
2.2.2 In 20 cm thick retaining/shear wall. m2 30.80 0.00
2.2.3 In 20 cm thick suspended top slab m2 11.78 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To bottom slab m2 5.58 0.00
2.3.2 To retaining/shear wall. m2 61.60 0.00
2.3.3 To suspended top slab m2 11.94 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For bottom slab
Dia 12 mm deformed bar Kg 444.00 0.00
2.4.2 For retaining/shear wall
Dia 8 mm deformed bar Kg 89.00 0.00
Dia 12 mm deformed bar Kg 1,025.00 0.00
2.4.3 For floor slab on grade
Dia 8 mm deformed bar Kg 12.00 0.00
Dia 12 mm deformed bar Kg 271.00 0.00
2.5 Internal surfaces of concrete cattle waste holing tank to be thoroughly cleaned and prepared by removing all dirt, laitance, grease, oil, algae, and loose material; all honeycombed, defective, or uneven surfaces to be repaired and made good with approved cement–sand mortar to provide a sound and smooth substrate. Supply and apply a two-component elastomeric cementitious waterproofing coating, potable-water approved, such as Nitocote CM210 or approved equivalent, to floors and walls, strictly in accordance with the manufacturer’s written instructions regarding surface preparation, priming, number of coats, minimum dry film thickness, curing, and protection. All pipe penetrations and exposed services within the tank to be treated with approved bituminous paint or compatible sealing system prior to application of the waterproofing coating. Item to include all materials, labor, tools, equipment, surface preparation, application, testing, protection, and completion of the works. Waterproofing system to be applied by the manufacturer or an approved authorized applicator, providing material and workmanship guarantees to the Employer. m2 38.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
SAWAKIN- VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.7-Site Works-Civil
1.1-Hard-scaping USD 0.00
1.2- Soft Scaping USD 0.00
2 Perimeter Fence with Gate USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 Hard-scaping
1.1.1 Clearing and grubbing of existing surface, including removal of vegetation, topsoil, and debris, to a depth of 40 cm and disposal as directed by the Engineer. m2 114.35 0.00
1.1.2 Selected fill to 95% MDD, including watering and rolling as shown the drawing m3 22.87 0.00
1.1.3 Supply, place, spread, water, and compact approved selected gravel material as capping layer to compound surface floor, including leveling, dressing to required camber/slope, and compaction to specified density as per specification and Engineer’s approval. m2 114.35 0.00
1.1.4 Supply and place crushed stone base course (C-4) 10 cm thick, including spreading, watering, and compaction to 95% MDD. m3 19.44 0.00
1.1.5 Supply, lay, and compact 7 cm thick Asphalt Binder Course using approved bituminous mix, laid in well-prepared and compacted layers over an approved base, in accordance with specifications and Engineer’s instructions. m2 114.35 0.00
1.1.6 Edge restraint using concrete curb (15 × 40 cm) including excavation, formwork, placing, and finishing. ml 48.40 0.00
1.1.7 Supply and install resin bound gravel surface comprising washed and dried natural aggregates mixed with UV-stable polyurethane resin, laid to specified thickness over a prepared and approved base, including finishing to a smooth, permeable, and durable surface in accordance with the specifications and Engineer’s instructions. m2 114.35 0.00
1.1.8 Supply and lay hand-dressed natural basalt/granite cobblestones (approx. 150×150×150 mm), tightly packed with joints filled with sand or cement-sand slurry as directed by the Engineer. The work shall includes all the necessary incidental works to complete the work such as surface preparation work. excavation, fill and cement sand slurry as per the detail Ar. drawing. The edge restaint curb stone measured in item 1.1.6. m2 5.95 0.00
Total Carried to Summary (USD) 0.00
1.2 Soft-soaping
1.2.1 Clearing and grubbing of existing surface, including removal of vegetation, topsoil, and debris, to a depth of 60 cm and disposal as directed by the Engineer. m3 37.80 0.00
1.2.2 Supply, place, spread, water, and lightly compact approved loamy (loam) soil for soft landscaping works, free from stones larger than 20 mm, roots, debris, weeds, and other deleterious materials, and suitable for plant growth. Loam soil shall have good drainage and adequate organic content, as approved by the Engineer. The rate shall include supply of soil, transportation, placement to the required levels and thicknesses, watering, light compaction, trimming, leveling, and all labor, tools, and equipment necessary to complete the work as specified. avg. depth 300mm m3 18.90 0.00
1.2.3 Supply, well decomposed animal manure or equivalent organic material to be mixed with the topsoil averagely 300mm and to use in backfilling of planting pits. Price shall include all the necessary works to complete the work. Provide 1kg sample and details of supplier With quotation for Landscape Architect’s approval. m3 18.90 0.00
1.2.4 Provide and plant grass as selected by the landscape architect. price includes grass as per the detail Architectural drawing. m2 63.00 0.00
1.2.5 Maintenance of lawn , grass, trees, shrubs, seasonal flower bed, other plantation and horticultural operations for weeding, watering, spreading of manure, good earth , fertilizers, spray of insecticides, fungicides, hoeing, pruning of tree/shrubs/hedge plants grassing garden swords, anti-termite treatment. Rates to include cost of material, all labor, tools & tackles, cost of manure, earth, fertilizer, pesticides etc. and also providing complete arrangement at site/sites for grass cutting by brand new power run lawn mower with skilled machine man & labor, diesel, lubricant to ensure mowing on barns and by manual labor through garden sward on the slop of under pass of the grass at least 3 times / month complete Month 2.00 0.00
1.2.6 Provide plants specially selected and nursery grown shade trees. Price supply of plants and planting as per the detail Architectural drawing. No 11.00 0.00
Total Carried to Summary (USD) 0.00
2 Galvanized Steel Wire Mesh Perimeter Fence with Gate
2.1 Supply, fabricate, and install galvanized steel wire mesh perimeter fence comprising 60 × 60 × 3 mm RHS vertical posts spaced at 2500 mm centers, fixed in concrete pad foundations, with top and bottom horizontal rails (60 × 60 × 3 mm RHS). The fence infill to be galvanized steel wire mesh (Ø 2.5 mm, 25 × 25 mm grid) securely fixed to the frame.The rate shall include excavation, concrete works, anti-rust treatment, metal painting, and provision of a main gate (2700 mm width) fabricated from similar materials, complete with all accessories, in accordance with specifications and Engineer’s instructions. ml 90.00 0.00
Total Carried to Summary (USD) 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
SAWAKIN- VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.8-Site Works-Electrical
ITEM DESCRIPTION UNIT QTY RATE TOTAL
1 Manhole for Electrical Systems
. Construct rectangular double red burnt brick electrical manholes of internal dimensions 800mm × 800mm × 700mm in accordance with the detail drawings and specifications. The manhole shall comprise 250mm thick double red burnt brick masonry walls, internally plastered with cement-sand mortar, a 100mm thick reinforced concrete base slab, and a 100mm thick removable reinforced concrete cover slab complete with flush-type cover, all as approved by the Engineer. The rate shall include excavation to the required depth, disposal/cart-away of surplus excavated material, back-filling and compaction around the structure, supply and placement of concrete, reinforcement, form-work, brick masonry, plastering, curing, and all associated civil works, labor, materials, tools, and incidentals necessary for the complete and proper construction and functioning of the electrical manhole system. Set 7.00 0.00
2 Light Fittings and Lamps 0.00
. Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing. IEC 60969 standards or equivalent and type approved 0.00
LED Solar Street Lights for Outdoor, atleast 15000 Lumens DA high-brightness, all-in-one solar street light for perimeter lighting, powered by sunlight with no electricity costs. Key Specifications Brightness: ≥15,000 lumens (bright as daylight) Light Type: LED (SMD 2835 or CREE 3030 chips) Color: Cool white (6000K–6500K) Solar Panel: 150-watt monocrystalline (charges in 6 hours) Battery: LiFePO4, ≥7-year lifespan, 3-day backup capacity. Operation: Dusk-to-dawn (auto on/off with daylight sensor) Motion sensor (full brightness on movement, dims to save energy) Remote control (adjust brightness, set timers) Weatherproof: IP65 (waterproof, dustproof, works in rain or heat) Material: Aluminum housing, tempered glass cover Runtime: 11 hours after 6-hour charge; up to 18 hours in dim mode Installation: Pole or wall mount (6ms height), no wiring needed Durability: Works in -22°F to 140°F; 50,000+ hour lifespan Warranty: 3–5 years No 8.00 0.00
3 Documentation 0.00
. Engineering, electrical installation as built drawings and O&M manuals. Qualified Set 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
SAWAKIN- VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.9-Site Works-Sanitary
SITE SANITARY WORKS
1 SITE WATER SUPPLY SYSTEMS USD 0.00
2 SITE WASTE WATER DRAINAGE SYSTEMS USD 0.00
3 ROOF & SURFACE RAIN WATER DRAINAGE SYSTEM USD 0.00
4 GENERAL ITEMS USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 WATER SUPPLY SYSTEMS
1.1 Site Water Supply Piping Systems
1.1.1 Supply,laying and test Cold drinking water pipes from municipality line to ground water tank(GWT). The pipe shall be PN16 DN50 High Density Polyethylene (HDPE) made of pure PE 100 rawmaterial and be laid in trench as shown in the sanitary site drawing. Provide 100mm thick sand bedding material rammed and tamped and 150mm thick approved material to cover the pipe all as per the typical site trench section and detail.Unit price shall include excavation, backfilling and cart away the excess quantity with all assistance civil works and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 10.00 0.00
1.1.2 Supply,laying and test Cold drinking water pipes from ground water tank(GWT) to transfer pump and to elevated water tank(EWT). The pipe shall be PN16 DN32 High Density Polyethylene (HDPE) made of pure PE 100 rawmaterial and be laid in trench as shown in the sanitary site drawing. Provide 100mm thick sand bedding material rammed and tamped and 150mm thick approved material to cover the pipe all as per the typical site trench section and detail.Unit price shall include excavation, backfilling and cart away the excess quantity with all assistance civil works and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 12.00 0.00
1.1.3 Supply,laying and test Cold drinking water pipes from gelevated water tank(EWT) to building block entrance where branched to water points (usable water supply)and nearby drainage lines (for overflow & washout piping). The pipe shall be PN10 DN40 PPR made of pure original rawmaterial and be laid in trench as shown in the sanitary site drawing. The unit price shall include piping bottom drain with valves piping system from EWT connected with overflow and connected to near by drainage ditch, air vent with insect screen and all support fixting work with related civil works. The unit price shall also consider and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 20.00 0.00
1.2 Supply and fix chrome service valves/isolation valve of approved standard before wet areas, or hand wash basins, water closets and other fixtures. Complete with unions, elastic water proofing, hand wheels of normal quality and with all other necessary accessories.
1.3 Construct standard a double brick wall,R.C base slab & R.C cover valve chamber compatible to valve size at specific position shown on the drawing with the respective PN6 bronze isolating valve.The price shall include excavation of a pit, cart away and backfilling.
1.3.1 Valve chamber with DN : variable isolation valves. № 4.00 0.00
1.4 Supply, installation, testing, and commissioning of domestic cold-water meter of multi-jet or volumetric type, suitable for potable water application in the animal health clinic water distribution system, complying with ISO 4064 / OIML R49 standards.Water meter shall be of DN50 nominal size, with brass or epoxy-coated ductile iron body, sealed dry dial register, and corrosion-resistant internal components. The meter shall be Class B or R80 accuracy, with a nominal working pressure of 16 bar, and maximum temperature 30°C.Each meter shall include couplings, strainer, and non-return valve, islation valve at each end and be installed in an accessible, ventilated, and protected meter chamber.All meters shall be factory-calibrated, certified, and permanently marked with serial number, flow class, size, and manufacturer identification. № 1.00 0.00
1.4 Water Reservoirs
1.4.1 Elevated water tank[EWT]
Supply, install, and commission a high-quality fiberglass (or equivalent) water tank with a nominal capacity of 2,500 liters for potable water storage, elevated 6 meters above ground on a support structure as per the provided sanitary and structural detail drawings. Tank Specifications: Material: Fiberglass reinforced plastic (FRP) or equivalent, approved for potable water storage, compliant with relevant standards ( BS EN 13280 or equivalent). Capacity: 2,500 liters (nominal). Design: Vertical seated(bottom diameter < 2m , suitable for external exposure with UV-resistant coating to withstand harsh weather conditions. Accessories: Manhole: Watertight manhole (minimum 600 mm diameter) with a lockable, weather-resistant cover to prevent contamination and ensure safety. Overflow Pipe: Minimum DN50, directed to a near by rain water drainage point with insect-proof mesh. Level Sensor: Automatic water level sensor/controller to start/stop the transfer pump. Inlet Pipe: Minimum DN32, fitted with a PN16 bronze gate valve. Outlet Pipe: Minimum DN40, fitted with a PN16 bronze gate valve and an expansion joint to accommodate to absorb any pipe movement. Drain Pipe: Minimum DN50, fitted with a PN16 bronze gate valve for complete tank drainage, directed to a designated drainage point. Fittings: All pipes and fittings shall be corrosion-resistant, suitable for potable water, and compliant with relevant standards (BS EN 545 or equivalent). Set 1.00 0.00
1.4.2 Ground water tank[GWT]
Supply, install, and commission a high-quality fiberglass (or equivalent) water tank with a nominal capacity of 5000 liters for potable water storage, at ground level as per the provided sanitary and structural detail drawings. Tank Specifications: Material: Fiberglass reinforced plastic (FRP) or equivalent, approved for potable water storage, compliant with relevant standards ( BS EN 13280 or equivalent). Capacity: 5000 liters (nominal). Design: Vertical seated(bottom diameter < 2m , suitable for external exposure with UV-resistant coating to withstand harsh weather conditions. Accessories: Manhole: Watertight manhole (minimum 600 mm diameter) with a lockable, weather-resistant cover to prevent contamination and ensure safety. Overflow Pipe: Minimum DN50, directed to a near by rain water drainage point with insect-proof mesh. Level Sensor: Automatic water level sensor/controller to start/stop the transfer pump. Inlet Pipe: Minimum DN50, fitted with a PN16 bronze gate valve. Outlet Pipe: Minimum DN32, fitted with a PN16 bronze gate valve and an expansion joint to accommodate to absorb any pipe movement. Drain Pipe: Minimum DN50, fitted with a PN16 bronze gate valve for complete tank drainage, directed to a designated drainage point. Fittings: All pipes and fittings shall be corrosion-resistant, suitable for potable water, and compliant with relevant standards (BS EN 545 or equivalent). set 1.00 0.00
1.5 Potable Cold Water Pumping system
1.5.1 Supply, fix, test and commission approved quality duplex vertical inline water pumps to push potable water to elevated water tanks to be distributed to every demanding buildings of the compound .As per the manufacturer's instruction and drawing shown . Price shall include all the necessary valves( one-way and stop valves), water hammer arrestor , common base plate ,automatic level control sensors & switches to start/off & to protect pumps from dry running & control panel .The price shall include all the necessary accessories required for the proper operation of the system but not specified or shown on the drawing. The pump shall be equiped with a single-phase transfer pump control board to manage water levels in an elevated water tank and ground water tank, featuring a compact IP65-rated enclosure (stainless steel or powder-coated mild steel), industrial-grade PLC, 4-inch touchscreen HMI for real-time monitoring and manual override, ultrasonic or float-type level sensors (2 nos. per tank) for accurate water level detection, control logic for automatic pump start/stop based on setpoints with sequential operation to minimize load, thermal overload relays, dry run protection via sensors or current monitoring, single-phase failure protection, surge arrestors, flame-retardant copper wiring, dedicated earthing, real-time pump status and alarm monitoring (high/low water levels, pump faults) on HMI, compliant with IEC standards and local regulations, complete with installation, testing, as-built drawings, operation manuals, training, and a 2-year warranty, designed for a 10-year operational life. Flow rate[LPS] = 0.694 @ 10 meter head Reference Model : Brand: DAB Model:KLPE 40-1200 with respective control systems and sensors. Set 1.00 0.00
Total Carried to summary USD 0.00
2 WASTE WATER DRAINAGE SYSTEMS
2.1 Providing, laying and jointing of internal uPVC PN-10 waste pipes with all uPVC pipe fittings including jointing with solvent cement joints and testing of joints etc. according to where shown on the drawings.Complete with all the necessary fittings. Provide cleaning detail for all waste water riser pipes as per the detail drawing.
2.1.2 Diameter 110mm ml 14.00 0.00
2.1.3 Diameter 160mm ml 37.00 0.00
2.1.3 Diameter 300mm ml 14.00 0.00
2.1.4 Construct rectangular manhole out of 250mm thick double brick walls,internal dimension 600mm x 600mm x 850mm (average depth),internally plastered with three coats of cement/sand mix ratio1:3 ,on a base of precast R.C slab of size ,1300mm x 1300mm x100mm , including benching and bottom channeling with mass concrete.Slab shall be reinforced with dia.8mm reinforcement bar c/c 130mm bothways. Provide 150mm thick granular materials beneath the slab,on a compacted earth . Manhole shall have precast R.C cover slab, each,size, 740mm x 740mm x 100mmreinforced with diameter 8mm steel barc/c140mm bothways,including diameter 14mm steel ring handle with supporter bar all in accordance with the given detail drawings .Unit price shall include excavation of the pitto a depth of 800mm (average) and cart away of the excavated soil. № 8.00 0.00
2.1.5 Ditto No 2.1.4 but size(length x width x depth)[mm]= 400 x 400 x 400 gully trap for gray water drainage № 3.00 0.00
Total Carried to summary USD 0.00
3 ROOF WATER DRAINAGE SYSTEM
3.10 Construct a rectangular open channel designed to collect and convey storm water runoff from around the building perimeter. The channel is made of 20cm thick masonry bed, 40cm thick side masonry wall and whenever the walk way, ramp and car way crossing the top part will be covered with pre case concrete cover. The internal part of the channel shall be plastered. The work shall include excavation, cart away , fill, masonry bed, wall, plastering , pre-cast concrete cover at crossing and all incidental work to complete work as per the project’s detailed drawings. The channel longitudinal slope of 1% (1:100) shall be maintained. Where the natural ground slope exceeds 1%, the contractor shall follow the greater natural ground slope to ensure positive drainage and avoid ponding. ml 90.00 0.00
Minimum Ditch-: SIZE[mmXmm] = 225 X 200
3.20 Ditto No 2.1.3 but for roof and surface water drainage system. № 10.00 0.00
3.30 Ditto No 2.1.4 but for roof and surface water drainage system. № 2.00 0.00
3.40 SURFACE WATER DRAINAGE CONNECTION TO ROADSIDE DRAINAGE LINE Scope includes but is not limited to: • Supply and installation of DN300 uPVC pipe (Class/SN as per local municipality standard for underground non-pressure drainage) from the manhole inside the clinic compound to the roadside drainage line. Total length to be verified on-site. • Pipe shall be laid at a gradient of 0.5% to 1% (1 in 200 to 1 in 100) to ensure self-cleansing velocity and prevent siltation. • Connection to existing manhole inside clinic compound (600mm x 600mm internal size, with invert level above road side drainage invert). Includes breaking into manhole wall, making good, and providing a proper connection. • Connection to roadside drainage line (standard road side channel/drain). Includes forming a proper junction at the outfall point. The connecting pipe's invert level shall be set above the soffit (crown) of the roadside drain to prevent backflow during high-flow conditions in the main drain. • Supply and installation of all necessary fittings (bends, junctions, couplings, adaptors) as required for directional changes and connections. • All civil works: Excavation (including breaking existing surfaces), trenching, pipe bedding (sand/gravel), backfilling, compaction, and surface restoration to original condition. • Testing of the installed pipeline by means of water or air testing to ensure leak-tightness prior to backfilling. • All necessary permits, approvals, and inspections as required by the local municipality for connection to the public drainage system. Note: Contractor to verify all site levels, invert levels of the existing manhole and roadside drain, and confirm the required slope is achievable before commencement. All works to be carried out as per local municipality standards and approved drawings. ls 1.00 0.00
Total carried to summary USD 0.00
4 GENERAL ITEMS
4.1 Allow for Testing and commissioning of the entire plumbing installation by a Chartered Mechanical Engineer and obtaining a Test Certificate (3rd party testing to approval of the Engineer) including all off-site and factory testing; inspections to demonstrate compliance with relevant standards, operating the completed installation and submitting all relevant test records and authority approval. LS 1.00 0.00
4.2 All sanitary fittings supplied shall be provided with a minimum 5 year warranty, issued jointly and severally by the local supplier and the manufacturer. LS 1.00 0.00
4.3 Allow for preparation of Operationa and Maintenance Manual including site users training for the O & M Maual of all plumbing and mechanical appliances. LS 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
SAWAKIN- VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bill No.10-Signage
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 Directory Signs
Design, supply and install international standard Boy's, Girl's & PWD Toilet directional sign complete with pictogram (Girl's, Girl's & PWD toilet sign symbol) plus directional arrow that leading to the toilets. The sign shall also consist text “Boy's , Girl's & PWDToilet.” Sign shall be minimum size 300 mm × 400 mm, high quality tin: tin sign with retro design, metal tin, long-term use, not easy to damage, smooth surface, ...with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 1.00 0.00
2 Room Identication Signs
Design and supply signage with room number in accordance with this specification and as directed by the Architect. The material shall be made of 3-5mm thick wall mounted Acrylic signs. The size shall be 250mm x 30mm and letter height shall be 50-70mm for room number, 25-40mm room name letters and braille and tactile characters where applicable. The color and contrast between the text and background shall be high and the color shall be consistent with the veternary clinic branding (if any) or as per the Architect approval. The topography and information shall be Room number: Bold, large font (sans serif preferred), Room function/name: Smaller font beneath the number (e.g., Room 101 – Office) and Braille/tactile lettering placed below the printed text. The signage shall be fixed to the wall at 1.4–1.5 m above floor to centerline of sign on the latch side of the door, or directly on the door if wall space is not available and it shall be fixed with secure concealed fasteners or adhesive (depending on wall/door material). The supplier shall produce and submit Mock-ups for approval before mass production. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect.
2.1 Isolation Room No 1.00 0.00
2.2 Office No 1.00 0.00
2.3 X-ray room No 1.00 0.00
2.4 Preparation room No 1.00 0.00
2.5 Electric Room No 1.00 0.00
2.6 Rest rooms and Janitors with pictogram of gents, ladies and PWD No 4.00 0.00
2.7 Treatment room No 1.00 0.00
2.8 laboratory No 1.00 0.00
3 Safety and Compliance Signs
4.1 Design, supply and install Emergency Exit Sign in accordance with this specification and as directed by the Architect. The material shall be made of flame-retardant, impact-resistant ABS clear acrylic plate and shall comply with BS EN ISO 7010 Exit Symbol (E001) and shall have Multi-installation system: Hanging, wall or surface mounted depending on the location. The size of the letter height shall be minimum 150mm with a stroke width 19mm, color contrast to be white letters on green background and the sign shall consist pictogram of running man symbol + directional arrow that leading to exit doors depending the location of the Emergency sign plan on the drawing. The sign shall support internally illuminated and visible in smoke and low light and are powered by dual power 220-240V AC (primary), automatic 90 minutes minimum battery backup (Lithium-ion battery).The sign shall be fixed to exist access point at 2.00–2.50 m above floor level. The supplier shall produce and submit Mock-ups for approval before mass production or procurement. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect. No 4.00 0.00
4.2 Design, supply and install Entrance Sign in accordance with this specification and as directed by the Architect. The material shall be made of flame-retardant, impact-resistant ABS clear acrylic plate and shall comply with BS EN ISO 7010 Exit Symbol (E001) and shall have Multi-installation system: Hanging, wall or surface mounted depending on the location. The size of the letter height shall be minimum 150mm with a stroke width 19mm, color contrast to be white letters on green background and the sign shall consist text+ directional arrow that leading to entrance.The sign shall be fixed to entrance access point at 2.00–2.50 m above floor level. The supplier shall produce and submit Mock-ups for approval before mass production or procurement. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect. No 3.00 0.00
4.3 Supply and fix 3mm rigid PVC/acrylic Fire Extinguisher sign (300mm x 100mm) with 50mm high ISO-compliant white lettering on red background, including all fixings and installation. No 7.00 0.00
4.4 Supply directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. Supply and install directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. No 1.00 0.00
4.5 Supply emergency assembly point safety sign complete with standard ISO 7010 pictogram (E007: four people symbol) and text “EMERGENCY ASSEMBLY POINT.” Sign shall be fabricated from 3 mm thick photo luminescent rigid PVC or aluminum composite panel, minimum size 600 mm × 600 mm, with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
SAWAKIN- VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.10-Day Works
1 LABOUR USD 0.00
2 MATERIAL USD 0.00
3 PLANT USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
(ALL PROVISIONAL)
In accordance with the Conditions of Contract, the Contractor will be paid day work rates for extra work that cannot properly be measured and valued, and the Contractor is to insert in the space provided below the basic rates and costs of labour,materials and plant as described hereunder:-
1.1 MASON hours 1 0.00
1.2 CARPENTER hours 1 0.00
1.3 SCAFFOLDER hours 1 0.00
1.4 JOINER hours 1 0.00
1.5 PLUMBER hours 1 0.00
1.6 ELECTRICIAN hours 1 0.00
1.7 PLASTERER hours 1 0.00
1.8 PAINTER hours 1 0.00
1.9 LABOURER hours 1 0.00
TOTAL in USD 0.00
1.10 To the basic net rates of labor used for work carried out on day works, an addition 25% percent which is to include for task work and incentive schemes, tools, standing, scaffolding, supervision, insurance, transport profit and overheads.
To collection of Labour Day works 0.00
2.1 Cement Per Tonne 1 0.00
2.3 Aggregate (grade 25 - 5mm) m3 14 0.00
2.4 Steel reinforcement
(i) Mild steel bar Kg 1 0.00
(ii) High tensile bar Kg 1 0.00
2.5 Timber formwork Per SQ.M 1 0.00
2.6 Paint, Gloss Per 4 Litres 1 0.00
2.7 Paint, Emulsion Per 4 Litres 1 0.00
2.8 Mahogany Varnish Per 4 Litres 1 0.00
2.9 100mm diameter uPVC rainwater downpipe 6M Per Each 1 0.00
2.10 Ditto bends Per Each 1 0.00
2.11 Ditto offsets Per Each 1 0.00
2.12 Ditto watershoe Per Each 1 0.00
2.13 Fixing brackets Per Each 1 0.00
2.14 Fixing screws Per Packet 1 0.00
2.15 75mm thick x 375mm wide weather/throated cills Per M 1 0.00
2.16 4 mm Clear sheet glass Per SQ.M. 1 0.00
2.17 100mm long Flush bolt Per Each 1 0.00
2.18 Indicator Signage Per Each 1 0.00
2.19 400mm x 200mm x 100mm hollow concrete blocks Per 1000 1 0.00
2.20 300mm x300mm x 8mm Ceramic floor tiles Per SQ.M. 1 0.00
2.21 150mm x 150mm x 6mm white glazed wall tiles Per SQ.M. 1 0.00
2.22 25mm x 3mm earth copper tape Per M 1 0.00
2.23 35mmsq bare copper cable Per M 1 0.00
2.24 6mmsq bare copper cable Per M 1 0.00
2.25 2.5mmsq. TWE copper cable Per M 1 0.00
2.26 2.5mmsq. SC PVC-I copper cable Per M 1 0.00
2.27 4.0mmsq. SC PVC-I copper cable Per M 1 0.00
2.28 10.0mmsq. 3C PVC-SWA-PVC copper cable Per M 1 0.00
2.29 20mm diameter galvanised steel tubing 6M Per M 1 0.00
2.30 20mm diameter galvanised steel tee Per Each 1 0.00
2.31 20-15mm diameter reducer Per Each 1 0.00
2.32 110mm diameter uPVC soil pipe 6M Per Each 1 0.00
2.33 50mm ditto waste pipe 6M Per Each 1 0.00
2.34 110mm ditto single branch access Per Each 1 0.00
2.35 50mm ditto sweep tee Per Each 1 0.00
2.36 Single bowl, single drainer stainless steel sink size 2000 x 600mm Per Each 1 0.00
To Collection 0.00
2.37 To the basic nett rates of materials used for work carried out on dayworks, an addition of 25% which is to include for unloading and storing as necessary, the use of hand plant, and machinery etc. available on site, profit and overheads.
To collection of Material Day works 0.00
3.1 Portable Compressor with 2 breakers or equivalent with 1500 mm hoses and reels hours 40 0.00
3.2 Damp Truck (0.75 tonne) hours 40 0.00
3.3 Lorry seven tonne tipper hours 40 0.00
3.4 Concrete Mixer (14/10) complete for weight batch mixing hours 40 0.00
3.5 50 mm self priming centrifugal pump with hose and ancillary equipment hours 40 0.00
3.6 Concrete Vibrators hours 40 0.00
To Collection 0.00
3.7 To the basic rates of plant used for work carried out on dayworks, an addition of 25% per cent, which is to include for driver and/or attendance, fuel and consumable stores supervision, insurance, road licence,profit and overheads.
To collection of Plant Day works 0.00
Name of Signatory:
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Exavation Work
ITEM TYPE SIZE No M3
Exavation & Earthwork
1.01 site clear
cad area including appron,ditch
1.02. Bulk Excavation to reduce level
1.03. Footing Excavation
1.04. ditto but from 1.50-3.00m
1.05.Trench Excavation
with 0.15 allowance each side
1.05. Back fill under hard core
ddt stone masonry wall
1.06.Ditto but around footing
Excavation Volume
ddt lean concrete
ddt footing pad
ddt column 0.00
1.07.Ditto but around masonry
with 0.25 allowance each side
1.08. Cart away
1.09. hard core
1.10. Dewatering
3.01. construction joint
10mm thich joint filler/sila or fiber board
4. Masonry Item
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Sub-Structure Concrete
CONCRETE FORM WORK
Type Size No Total Size Total
2.1. Lean Concrete
Total 118.86 m2
Under masonry wall
Under hard core
2.2 C -25 CONCRETE
Foundation Column
Total 5.04 67.20
200mm thick slab
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Super-Structure Concrete
CONCRETE FORM WORK
1.1. C-250 Concrete
A. Elevation Column
From Ground-roof floor
150mm Concrete gutter
Total 9.05 m3 129.05 m2
100mmSun breaker
Total 22.11 m3 23.32 m2
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Architectural
ITEM TYPE SIZE No Total
2.01. 20cm thick H.C.B wall screening
2.01. 20cm thick H.C.B wall
ddt opening 0.00
3. Roofing Work
3.04. Valley gutter
Gutter light wt concrete
Gutter water proofing
B. Steel Structure Beam
C. RHS Truss system
C.1 RHS 60 x 60 x 3mm upper and lower member
Total length 188.60
Unit Wt. for the section 5.37
Total Kg 1,012.67
C.2 RHS 50 x 50 x 3mm upper and lower member
Total length 24.00
Unit Wt. for the section 4.43
Total Kg 106.26
C.3 RHS 40 x 40 x 3mm Diagonal & verical member
Total length 181.85
Unit Wt. for the section 3.49
Total Kg 633.82
D.1 80 x 4 x 3mm fixed
Total length 434.10
Unit Wt. for the section 5.37
Total Kg 2,330.86
Base plate 200 x 200 x 6mm
Total plate 56.00
7. Finishing work
6.0 Two coats of plastering
Internal HCB wall plastering
to receive gypsum chuck
ddt opening 0.00
External plastering
ddt opening 0.00
Bill No.2 Staff Residence Block
For Ariya kayisa Primary School
Summary of Reinforcement for Sub-structures & Super-Srructure
Foundation Footing
Foundation Column
Ground Floor Beam
Ground Floor Slab
Super-Structure
Elevation Column
REINFORCING BAR SCHEDULE
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Date , Sep 28,2025
Bill No.-2-Staff Residence Block Consultant;- UNOPS-ETMCO
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Foundation Colum --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Foundation Column --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Ground floor slab --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
internal partiton area --- --- --- --- --- --- --- ---
REINFORCING BAR SCHEDULE
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Date , Sep 28,2025
Bill No.-2-Staff Residence Block Consultant;- UNOPS-ETMCO
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Elevation Column --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
United Nations Office for Project Services
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
Tender Reference:
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR),
CONSTRUCTION WORKS FOR VETERNARY PROJECT
BILL OF QUANTITIES (BOQ)
- Bill Nr.1 - Mobilization
- Bill Nr.2 to 10-Civil, Electrical & Sanitary Works-BoQ
- Bill Nr.10 - Day Works
NOTE: It is a MANDATORY requirement for bidders to complete and return both this excel BOQs and their respective duly signed pdf for further reference
Failure to complete all sections of the BOQ may result to automatic disqualification of your bid.
PREAMBLE TO BILLS OF QUANTITIES
1 Priliminary Condition
1.1 This Specification shall be read in conjunction with the Particular Technical Specifications provided under each work discipline, as well as the latest edition of the Sudan Standard Technical Specifications for Building Works, or any other internationally recognized standards commonly adopted in Sudan.
1.2 The Bill of Quantities (BoQ) shall be measured in accordance with the latest edition of the Sudan Standard Methods of Measurement for Building Works.Pro Memoria (PM): Indicates that the cost of the item is deemed to be included and distributed within other related work items in the BoQ. No separate payment will be made.Lump Sum (LS): Indicates that the item is priced as a fixed total amount, with no adjustment or variation permitted to the total price regardless of actual quantities executed.
1.3 The contractor has fully understood the scope of works by minutely having studied the drawings and Bill of Quantities with specifications, and by having visited the site. He will, on his own initiative and before the works start and in his best ability, notify the consultant of works which are not mentioned in the BoQ and/or the specifications and/or the drawings, which are necessary to execute the construction as envisioned in the drawings. Thus, after the works have started, the contractor cannot rely on incompletions in the consultants' work to make claims of any kind. Indeed, the contractor will add upon the specifications according to his own insight and professional experience. If there are works to be done which are not specified in this BoQ, it is up to the consultant to decide wether these works are variation works which need change orders, or wether these works are included in the items and their prices in the BoQ.
1.4 The contractor has to execute all works which have a direct or indirect impact on safety and availability of infrastructure (water, sewage, electricity, …) in as short a period as feasible.
1.5 The contractor will secure the structural and functional integrity of the exsiting buildings nearby the project site during construction work as well as of the building’s surroundings such as but not limited to public road, gate, lawn. He will study and execute the necessary scaffolding to support the building, in order to avoid any cracks, settlements, or crumbling. This scaffolding to support the building during the works are included in the prices given. Debris will be cart away to certified debris places in the area. In no way, debris will be stored, buried or burned on site.
1.6 After the works, the contractor will do a thorough cleaning of the construction site, this means cleaning of all excess mortars, cement bags, excess blockwork, excess tile jointing – in short any construction remnant which hinders the proper use of the house upon site hand-over.
NHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
1.7 In general the contractor will put his professional experience and craftsmanship to work, in order to get a holistically well-constructed building, to the highest and most up-to-date standards of Sudan Construction & international Culture.
2 Organisation of Construction Site
This includes all necessary preparations to execute the works; at least from the beginning until the end of the works; according to the best knowledge and experience of the contractor: at least conform local standards.
The objectives of the Bill of Quantities are
(a) to provide sufficient information on the quantities of Works to be performed to enable bids to be prepared efficiently and accurately; and
(b) when a Contract has been entered into, to provide a priced Bill of Quantities for use in the periodic valuation of Works executed.
In order to attain these objectives, Works have been itemized in the Bill of Quantities in sufficient detail to distinguish between the different classes of Works, or between Works of the same nature carried out in differently or in other circumstances which may give rise to different considerations of cost.
4 The Bills of Quantities for the Works comprise the following:
Preamble to Bill of Quantities
List of principal Quantities
Bill Nr. 1 Mobilization
Bill Nr. 2 - 9 Civil, Electrical Installation & Sanitary Installation
Bill Nr. 18 Day Works
5 The Contractor’s unit rates in these bills are to cover supplying of materials, taking delivery, transporting, loading and off loading inspection, storage, stacking, landing, preparation, installation including provision of all labour, requirement false work, temporary support, surface preparation and testing of the works. The rates shall include all applicable taxes and duty. The cost of testing of the materials to be used in the works unless otherwise provided is to be included in the rates of the respective Bill items.
6 Measurement for payment shall be for the complete installation and having passed all necessary tests.
7 Work shall not be executed on a Day work basis unless ordered in writing by the Consultant on approval by the Employer. The rates entered in the Day works Bill of Quantities shall apply to any quantity of Day work instructed by the Consultant. Nominal quantities have been indicated against each item to permit the extended total to be carried forward to the Grand Summary.
8 “Rates and prices shall be inserted in the rate and total columns of the Bill of Quantities in USD
9 Bills of Quantities are to be read in conjunction with the Instructions to Bidders, the Conditions of Contract Data, the Specifications and the Drawings. The quantities stated against each item in the Bills of Quantities, with the exception of those items specifically marked ‘sum’, are the estimated quantities of the Work to be executed by the Contractor in fulfillment of his obligations under the Contract.
10 The Contractor is required to check the number of the pages and should any be found to be missing or in duplicate he must inform the Engineer at once and have the same rectified.
11 No liability whatever will be admitted or claim allowed in respect of errors in the Contractor’s tender due to mistakes in the Bills of Quantities which should have been rectified in the manner described above.
12 The contractor shall not alter or otherwise qualify the text of these Bills of Quantities. Any alteration or qualification made without authority will be ignored and the text of the Bills of Quantities as printed will be adhered to.
13 Each item in the Bills of Quantities is to be priced. If any items are left un-priced it will be assumed that the value of the work described there under is elsewhere allowed for. The prices and rates to be inserted in the Bills of Quantities are to be fully inclusive of all costs and expenses which may be required for the construction of the work described, together with general risks, liabilities and obligations set forth or implied in these documents.
14 In no case will any claim for expenses incurred by the Contractor in preparation of this Tender be allowed.
15 The Contractor is solely responsible for the accurate ordering of materials in accordance with the Specifications, Drawings and Engineer’s Instructions and no claim for any loss or expense will be entertained for orders for materials based on the Bills of Quantities.
16 The quantities given in the Bills of Quantities are estimated and no claim by the Contractor for the final quantities being larger or smaller than the quantities given in the Bills of Quantities will be permitted except alows in accordance with the particular of the Conditions of Contract.
17 The dimensions given in the Drawings are generally in millimeters unless otherwise indicated. Levels are given in meters.
18 The term ‘provide’ or ‘supply’ used for any item shall be deemed to include transport to site, handling, storage and fixing complete, and the Bidder’s rate shall include for this.
19 The following abbreviations have been used in the Bills of Quantities:-
ml metre linear
m2 square metre
PS provisional Sum
Set Complete set of work with accessories & components
lot Complete set of work with accessories & components
PS provisional Sum
USD United States Dollar
uPVC un-plasticized poly vinyl chloride
HDPE high density polyethylene
GMS galvanized mild steel
PPE personal protective equipment
ASTM American society for testing & material
GW well-graded gravel
GP poorly-graded gravel
GM silty gravel, gravel-sand-silt mixtures
GC Clayey gravels, gravel sand-clay mixtures
SW well graded sands
SP poorly graded sands
SM silty sand, sand -silt-mixtures
SC clayey sands, sand-clay mixtures
AASHO American Association of State Highway and Transportation Officials,
ACI American Concrete Institue
RHS rectangular hollow section
PVD Physical Vapor Deposition
HCB hollow concret block
CBR california bearing ratio
MC medium curing
SDB sub distribution board
PDB pump distrbution board
20 Unless otherwise provided there are no separate measurement items for Contractual requirements. The Contractor is deemed to have included his costs for the Contractual requirement
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
TOKER VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
GRAND SUMMARY Amount in USD
1 Bill Nr.1 - Mobilization USD 0.00
2 Bill Nr.2 -Model Veternary Building-
2.1 - Civil Work USD 0.00
2.2 - Electrical Installation Work USD 0.00
2.3 -Sanitaryl Installation Work USD 0.00
3 Bill Nr.3 - Solar PV USD 0.00
4 Bill Nr.4 Pump Control Swith Shed with platform-Civil Work USD 0.00
5 Bill Nr.5 Septic Tank & Soak Away Pit-Civil Work USD 0.00
6 Bill Nr.6 Cattle Waste Holding Tank-Civil Work USD 0.00
7 Bill Nr.7 Site Works-Civil USD 0.00
8 Bill Nr.8 Site Work-Electrical USD 0.00
9 Bill Nr.9 Site Work-Sanitary USD 0.00
10 Bill Nr.10 Signage USD 0.00
GRAND TOTAL USD 0.00
11 Bill Nr.11 - Day Works USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
TOKER VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill Nr. 1- Moblization
1 SIGN BOARD USD 0.00
2 SITE SUPERVISOR TRANSPORTATION USD 0.00
3 SAFTEY HARNESS & PROTECTION USD 0.00
4 SAFTEY & SECURITY OF WORKS USD 0.00
5 SHOP DRAWINGS USD 0.00
6 Existing Condition/Demolishing Work USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 Contractor to provide a Project Identification sign size (200 cm × 200 cm), Contractor to submit shop drawing for UNOPS Engineer Approval, also 2 safety signs (120 cm x 120 cm). Saftey signed to be submitted to approval of Engineers. LS 1.00 0.00
2 Site Supervisor Office & Transportation
2.1 Providing offfice for supervion team completed with office Desk LS 1.00 0.00
3 Saftey Harness and Protection
3.1 2 No (Minimum) Safety Harness with lanyards , 3 fire powder 6Kg fire extinguishers, and selection of gloves & safety glasses to be kept in UNOPS Office at all time, also contractor should in his price include the cost of providing all his staff and work force with suitable PPEs ( i.e. Hard Hat, Safety Boot, Dust Masks, Safety Vests and Safety Glasses) Ls 1.00 0.00
4 Safety & Security of Works
4.1 Allow for providing safety and security for the Works and material as per the requirement laid under the Contract, including security lighting, lockable or open material storage areas, engaging security guards and / or any other measures as necessary. Cost shall include Road Safety awareness, and public traffic flow management during construction. LS 1.00 0.00
4.2 Providing, erecting, maintaining, and removing temporary site hoarding/fence made of corrugated iron sheets (C.I.S.) securely fixed to eucalyptus posts, including all posts, bracing, fixing materials, excavation, installation, maintenance, dismantling, and disposal upon completion. The hoarding shall be approximately 2.4 m high and installed along the site perimeter adjacent to the public road and other accessible areas, as directed by the Engineer, to prevent unauthorized access and ensure site security. ml 93.00 0.00
5 Shop Drawings
5.1 Allow for prepare and submit to the Engineer's Representative a complete set of Shop Drawings, as required to the specified scale(s), giving all details, as required by the Engineer's Representative, for the work executed. Submission shall be in 3 sets as hard copies, colour printed on A1 size paper and 01 set of soft copies in AutoCAD compatible version in a compact disc. LS 1.00 0.00
6 Existing Condition/Demolishing
6.1 Demolishing
The work shall be performed by qualified personnel who have ample experience in demolishing and safety work in order to avoid risk in the existing structure and in human life. Any useful dismantled materials shall be kept in proper manner and submitted to the client after proper cleaning. The contractor shall take all the responsibility of worker discipline in order to avoid disturbance and security issues at the work place and the entire compound. The contractor shall protect the existing area with approved standard plastic or other protective cover. Contractor is advised to investigate the scope of dismantling work before filling in prices.
The rate shall include breaking, cutting, dismantling, loading, hauling and disposal of all demolished materials, debris and unsuitable materials to an approved disposal area designated by the Engineer/Employer, including all labor, tools, plant, equipment, lifting and hauling facilities, water, temporary works, protection of adjacent structures and services, dust suppression, cleaning of the site, and all other incidental works necessary to complete the demolition safely and entirely in accordance with the drawings, specifications and Engineer’s instructions.
The contractor shall take all necessary precautions to prevent damage to adjacent buildings, utilities, pavements and other retained structures. Salvageable materials, if any, shall be separated and handed over to the Employer as directed by the Engineer. The area shall be left safe, clean, level and ready for subsequent construction works. The contractor shall submit methodology and work plan for approval by the Engineer before commencing the Works. contractor is advised to go through the detail of the building structure during pre-bid site visit.
A Demolition and complete removal of the Existing Building “B” as identified in the Architectural Drawing Legend, having a single story built up dimension of 9,100 mm × 5,200 mm and an average height of 2.80 m, comprising two rooms. The work shall include, but not be limited to, all necessary preparation, protection, temporary support and safety measures; dismantling and demolition of approximately six (6) reinforced concrete columns, grade beams, roof/tie beams and associated reinforced concrete footings extending to approximately 1.50 m below existing ground level; demolition and removal of all concrete prefab external envelope and internal partition walls; dismantling of the eucalyptus timber roof structure and removal of corrugated iron sheet (C.I.S.) roof covering; removal of all existing metal doors, windows, frames, fixtures and other associated building elements such as disconnecting electrical & sanitary system. Ls 1.00 0.00
B Existing Office Building labeled "C" in the Architectural drawing legend the horizontal projection size is 5200 x 5000mm Ls 1.00 0.00
C Demolition and complete removal of the existing wire mesh perimeter fence, comprising RHS steel structural framing with vertical supports spaced at approximately 4.00 m c/c and three (3) horizontal RHS support members between vertical posts. Each vertical support shall be dismantled and removed together with its approximately 400 × 400 × 500 mm reinforced/plain concrete foundation pad, including any embedded steelwork, fixing plates, bolts, ties and associated components. ml 75.00 0.00
6.2 Preparation of the existing dirt road at the interface with the new entrance gate interlocking pavement, including trimming and shaping the existing road edge to a firm and straight profile, removal of loose, soft, or unsuitable soil and debris, thorough cleaning and preparation of the interface, excavation and formation of the required transition area, provision and compaction of suitable subgrade and granular base material, installation of concrete edge restraint and proper connection of the new interlocking pavement to the existing dirt road to form a smooth, stable, and durable transition, all complete as directed by the Engineer. The rate shall include all labor, materials, equipment, excavation, supply and placement of selected fill and base course, watering and compaction, concrete edge restraint, hand tools, protection of adjacent works, trimming and grading, and all incidental works necessary to achieve a proper and durable transition between the existing dirt road and the new interlocking pavement. Ml 4.00 0.00
6.3 Removal and disposal of existing trees having a trunk diameter greater than 80 mm, including cutting, uprooting, complete removal of stump and roots, loading, transportation and disposal, backfilling and compaction of holes, and making good the affected area. Trees with a diameter 80 mm or less shall be considered under site clearing works. Where required by the Engineer, the Contractor shall replace removed trees by re-planting approved tree species in accordance with the landscaping plan. pcs 3.00 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
TOKER VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.1- Veternary Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 GLAZING USD 0.00
8 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 294.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 75.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 202.00 0.00
1.4 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 23.00 0.00
1.5 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 126.00 0.00
1.6 Ditto as above item 1.5 but around isolated footing. m3 188.00 0.00
1.7 Ditto as above item 1.5 but around masonry foundation wall. m3 12.00 0.00
1.8 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 391.00 0.00
1.9 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 177.00 0.00
1.10 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 217.00 0.00
1.11 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 104.00 0.00
2.1.2 Under masonry foundation wall m2 47.00 0.00
2.1.3 Under grade beam m2 22.00 0.00
2.1.4 Under slab on grade including ramp & outdoor treatment m2 177.00 0.00
2.1.5 Under masonry steps on grade m2 2.00 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 39.00 0.00
2.2.2 In foundation column. m3 4.00 0.00
2.2.3 In grade beams. m3 15.00 0.00
2.2.4 In 15 cm thick ground floor slab including ramps & outdoor tratment. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 177.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 55.00 0.00
2.3.2 To foundation column m2 45.00 0.00
2.3.3 To grade beams & ramps edge m2 155.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 8 mm deformed bar Kg 17.00 0.00
Dia 10 mm deformed bar Kg 53.00 0.00
Dia 12 mm deformed bar Kg 2,117.00 0.00
Dia 14 mm deformed bar Kg 819.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 244.00 0.00
Dia 14 mm deformed bar Kg 170.00 0.00
Dia 16 mm deformed bar Kg 818.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 327.00 0.00
Dia 14 mm deformed bar Kg 331.00 0.00
Dia 16 mm deformed bar Kg 1,020.00 0.00
2.4.4 For floor slab on grade, ramp slab & outdoor tratment slab
Dia 8 mm deformed bar Kg 648.00 0.00
Dia 10 mm deformed bar Kg 173.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 46.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 2.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 8.60 0.00
1.1.2 In top tie beams m3 10.60 0.00
1.1.3 In water tanker slab with beams m3 1.20 0.00
1.1.4 In lintel beams including roof vent windows m3 0.30 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 91.00 0.00
1.2.2 To top tie beams m2 108.00 0.00
1.2.3 To water tank slab with tie beam m2 9.00 0.00
1.2.4 To lintel beams including for roof vent windows m2 3.00 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 182.00 0.00
Dia 16 mm deformed bar Kg 812.00 0.00
1.3.2 For top tie beam
Dia 8 mm deformed bar Kg 270.00 0.00
Dia 14 mm deformed bar Kg 294.00 0.00
Dia 16 mm deformed bar Kg 1,101.00 0.00
1.3.3 For water tanker slab & beam
Dia 8 mm deformed bar Kg 8.00 0.00
Dia 10 mm deformed bar Kg 100.00 0.00
Dia 16 mm deformed bar Kg 28.00 0.00
1.3.4 For water tanker slab & beam
Dia 6 mm deformed bar Kg 8.00 0.00
Dia 12 mm deformed bar Kg 31.00 0.00
Total carried to summary USD 0.00
Walls shall be constructed from class 'B' hollow concrete block (H.C.B.). The blocks shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the blocks shall be in such a way that good key for plasterer is obtained on both side.
2.1 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. m2 349.00 0.00
2.2 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B), the hollow part shall be fully grouted with cement sand mortar and jointed in cement sand mortar mix (1:3) one side left for appropriate finishing and the other side left for to fix sika joint or fiber board.Price shall include cement sand mortar fill inside hollow part of the wall. For X-ray room back wall m2 62.00 0.00
2.3 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) with vertical & horizontal stiffeners bedded and jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. The stiffening methods and application shall be as per the detail structural dwg. Price shall include stiffening concrete and reinforcement.Price shall also include the recessed decorative wall part showing on the right & left side of the building.-for parapet wall m2 48.00 0.00
2.4 Supply and lay 10 cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. m2 6.00 0.00
2.5 Supply, delivery, preparation, and installation of combined brick layers of ( 20 cm + 10 cm),total 30cm thick red burnet brick wall cladding for internal X-ray room walls surface shown on the Ar. Drawing.The construction must comply with radiation protection requirements and shall be proper sealed with sika or fiber board to prevent radiation leakage. The material physical property shall meet the minimal standard to suit the intended purpose. The installation work shall be as per the architectural detail plan and shall be install from bottom up. The contractor shall submit the material sample. Shop drawing showing fixing details. Installation method and mockup sample shall be constructed for the Architect approval.price shall include 10mm thick SIKA or fiber board joint filler (wall substrate) & bonding bar with HCB wall. m2 62.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 235.00 0.00
3.2 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet ridge hip at the roof slope direction changes. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of ridge cap: 80 cm. m.l. 9.00 0.00
3.3 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 50.00 0.00
3.4 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel vally gutter, supported by the side truss members the work shall include all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 450 mm ml 4.50 0.00
3.5 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet copping at the top roof ridge exposed HCB wall. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of copping: 410 mm. m.l. 24.00 0.00
3.6 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 44.00 0.00
3.7 Supply and fix diam 110mm PVC down pipe. Price shall include 900 elbow connection, PVC liner with all the necessary fixing accessories. ml 52.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors and windows all as per the drawing. All doors should have vertical metal grill 25x25x2mm c/c 15cm for burglar proofing and with 0.5mm thick steel louver at top welded to frames and covered with approved mosquito net. All windows should have RHS 10x10x2mm welded to frames and with steel mesh for burglar proofing. All roof vent should have steel mesh welded on the frame. Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint. (glazing measured separately).
TW-1 size 150 x 85 cm no 2.00 0.00
D-1 size 180 x 255 cm-doble leaf door no 1.00 0.00
D-2 size 90 x 255 cm-single leaf door no 6.00 0.00
D-3 size 85 x 255 cm-single leaf door no 2.00 0.00
4,2 Supply, deliver, install, test, and commission factory made steel-framed, lead-lined radiation shielding X-ray door with vision panel, complete with all accessories and certification. The material shall be Steel door frame and solid core door leaf, factory fabricated, Lead lining to door leaf and frame equivalent to 2.0 mm Pb minimum, Vision panel comprising lead glass with equivalent 2.0 mm Pb shielding, Complete set of heavy-duty ironmongery including hinges, lockset, handles, and door closer, Perimeter sealing with radiation-proof gaskets to prevent leakage, Proper installation including lead overlap at joints and shielding continuity and the work shall include Testing, commissioning, and submission of radiation protection compliance certificate. All are as per the detail door and window schedule and engineers approval.
D-1' size 180 x 255 cm-doble leaf door no 1.00 0.00
D-2' size 90 x 255 cm-single leaf door no 1.00 0.00
4,3 Supply, fabrication, and installation of rectangular roof ventilation unit, overall size 80 cm × 40 cm, consisting of fabricated from 38 mm LTZ-profile, 0.16 cm thick frame. Joints to be welded with 4 mm continuous fillet welds, ground smooth and free of sharp edges. Infill woven wire mesh aperture 1.4 mm × 1.4 mm, wire diameter 0.45 mm, securely fixed to frame by recessed groove or retaining clips. Entire vent unit to be cleaned, degreased, and painted with on coat of anti-rust followed by two coats of metal paint. The color shall be approved by the Engineer and the work shall complete as per drawing. no 8.00 0.00
4.4 Supply, fabricate and fix metal guard rail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 120 × 120 × 6 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 1000 mm above finished floor level; two horizontal balustrade rails CHS Ø20 × 2.5 mm welded to vertical RHS posts; top handrail CHS Ø50 × 2.5 mm welded continuously; infill: vertically spaced CHS Ø20 × 2.5 mm at c/c 100 mm between the two horizontal rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 21.00 0.00
4.5 Supply, fabricate and fix metal ramp handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 15.00 0.00
4.6 Supply, fabricate, deliver, install, and paint steel cattle fence (balustrade type) comprising CHS vertical posts, horizontal rails, and base plates, fixed to concrete floor, complete in all respects. The work shall be Steel fence consisting of Ø100 × 5 mm CHS vertical posts (900 mm height) fixed to concrete using 170 × 170 × 6 mm base plates, spaced at maximum 1000 mm centers, with 4 No. horizontal Ø80 × 2.5 mm CHS rails welded to posts, including all welding, anchoring bolts, alignment, and accessories, finished with anti-rust primer and final metal paint (minimum two coats each), complete as per drawings and Engineer’s approval. ml 14.00 0.00
4.7 Supply and fix elevated water tanker seat metal guard rail all according to size and shape specified on the drawing . Price shall include connection plates, bolt and one coat of primer & two coats of synthetic enamel paint. ml 8.00 0.00
4.8 Ditto as above item and supply, fabricate, deliver,instal and paint steel structure ladder as shown the At. detail drawing. ml 8.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect steel structures using RHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel Structure Column
Steel structure columns are vertical primary load-bearing members, transferring axial loads (and occasionally bending) from trusses to foundations. Since columns are in direct contact with water during cleaning, apply bituminous damp-proof paint at the column base up to a height of 300 mm (30 cm) to prevent corrosion and moisture penetration. price shall damproof paint and stiffening plates as shown in the drawing. for measurment net RHS post will be considered execluding stiffening plates.
A.1 Steel structure column RHS sections of 100 × 100 × 4mm for veranda post. kg 218.00 0.00
B. Steel Structure Column Beam
The beam shall be welded column to column just below the top plate level where truss and column connected. At the end of the beam where there is no steel column. it connected with the building it will be fixed with plate at the concrete column/tie beam
B.1 RHS 80 x 60 x 4mm beam for veranda kg 280.00 0.00
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards. Price shall include gusset plat, connection plate when truss members connect and bolts other than anchor/J-bolt bolts.
C.1 RHS 80 x 80 x 4mm upper & lower truss member for T1 & T2 Kg 1,701.00 0.00
C.2 RHS 60 x 60 x 3mm upper & lower truss member for T1', T3, T4 & T5 Kg 424.00 0.00
C.3 RHS 60 x 60 x 4mm diagonal & vertical truss member for T1 & T2 Kg 685.00 0.00
C.4 RHS 50 x 50 x 4mm diagonal & vertical truss member for T3, T4 & T5 Kg 151.00 0.00
D. RHS Purlins 0.00
D.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 100 x 100 x 3mm L= 60mm angle iron. Price include angle iron. Kg 2,145.00 0.00
E. RHS Solar PV Support System 0.00
Supply, fabricate, deliver and install solar panel steel support structure complete with all necessary connection components. The work shall include provision of gusset plates, bolts, nuts, washers, and all fixing accessories required for proper assembly and stability of the structure.The rate shall include surface preparation and application of approved anti-corrosion primer and finishing paint. It shall also include proper sealing and waterproofing treatment where steel members penetrate the roof covering, ensuring no water leakage. All works shall be executed in accordance with approved shop drawings, specifications, and engineer’s instructions.
E.1 RHS 80 x 80 x 4mm steell structure frame member Kg 2,153.00 0.00
E.2 RHS 60 x 60 x 4mm steell structure frame member Kg 492.00 0.00
E.3 RHS 40 x 40 x 4mm purlin Kg 658.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate for verenda post-size 250 x 250 x 6mm with 4 dia 22 slotted holes. The plated is welded to the RHS post (fillet weld of 3mm throat thickness) and connected to the other plate fixed on concrete column. No 12.00 0.00
A.2 Base plate size 250 x 200 x 6mm with 4 dia 18 slotted holes for truss & ring beam. The plate is welded to the truss (fillet weld of 3mm throat thickness) and connected to ring beam. No 90.00 0.00
A.3 Top plate size 150 x 150 x 8mm for veranda post and RHS beam connection with bolt & nut. No 12.00 0.00
B Bolt with nut
B.1 Base plate/Anchor bolt dia. 16 Length 250mm for truss beam connection and to be weld to ring beam steel reinforcement No 180.00 0.00
B.2 Base plate/Anchor bolt dia. 20 Length 450mm for veranda post No 24.00 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of gypsum finish to internal HCB wall surfaces. m2 535.00 0.00
6.2 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of gypsum finish to internal exposed beam and column surfaces. m2 69.00 0.00
6.3 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive rendering finish to externall HCB wall surfaces. m2 205.00 0.00
6.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final rendering finish to external exposed beam and column surfaces. m2 112.00 0.00
6.5 Prepare the surface and apply final a 3 mm to 5 mm thick final skim coat using a 1:3 cement-to-fine-sand mortar mix. Fine sand must be sieved through a 1.18 mm mesh. The surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks to internal wall, beam & column surfaces. m2 604.00 0.00
6.6 Prepare the surface and apply final apply 15mm thick cement and sand rendering (1:3 mix) for external wall surface. Price includes surface preparation, hacking of concrete surfaces, wire mesh for joints, curing for 7 days. The rendering pattern shall be as per the Architect approval. m2 317.00 0.00
6.7 Prepare the surface, supply and construct 2 cm thick x 25 cm wide polished marble threshold for doors bedded on cement sand mortar 1:3. Price include 30mm thick cement sand mortar backing and white cement grouting. All are as per the detail Ar. Dwg. ml 10.00 0.00
6.8 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 59.00 0.00
6.9 Prepare the surface, supply and fix nominal thickness of 0.85 cm approved standard 60 x 60 cm non-slippery ceramic floor tiles bedded in an average 4.15 cm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 12.00 0.00
6.10 Prepare the surface and apply epoxy resin coating flooring as shown in the drawing- the epoxy flooring shall be suitable type for veternary clinic:- Epoxy floor, shall be applied on the concrete floor or 4.6 cm thick cement sand screed flooring using OPC cement and Rheomix 141 strengthening additive in order to achieve the required bedding strength for animal hoof. The application of the screed shall be leveled and finished with a fine texture screening while the concrete is fresh and it is preferable to hold the proper application of epoxy floor finish with out any additional leveling. screed to the base floor shall be done with proper slope as instructed by the engineer and shall be done as per the advice and follow up of the epoxy supplier in order to assure the bonding between the concrete slab and screed. The contractor should use bonding chemical agent primer that shall be approved by the Engineer. Price shall include screed, Rheomix 141 strengthening additive and epoxy floor finish. m² 38.00 0.00 4800 0 0 4800 #REF! #REF! #REF! #REF! #REF! #REF!
6.11 Prepare the surface and construct belt & brace flooring as shown the detail Ar. Detail drawing. The work shall be 1 x 2 cm slip resistance diamond grooved finish with non metalic dry shake hardner. All are as per the detail drawing, manufacturere instruction and Engineer approval. m² 93.00 0.00
6.12 10cm high 1cm thick chamfered ceramic skirting of matching color to floor tiles. ml 106.00 0.00
6.13 Supply and fix 30 x 60 x 0.85 cm ceramic wall cladding, of matching color to floor, stuck to wall with cement sand mortar 1:3 backing and grouting with white cement wash. Price shall include rod anchors to backing. Size, color and pattern according to architect's drawings. m2 106.00 0.00
6.14 Supply and fix granite stair tread bedded on cement mortar 1:3 price include mortar bed, nosing and chamfering. Color and pattern shall be approved by the Architect.
a) For entrance step-tread
- Tread size: (33 x 3 cm) ml 8.00 0.00
6.15 Ditto as above but riser.
a) For entrance step-rise
- riser size: (13.4 x 2 cm) ml 8.00 0.00
6.16 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick marble window sill. Price shall include cement sand mortar bed and cement grouting. ml 12.00 0.00
6.17 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick marble short wall copping. Price shall include cement sand mortar bed and cement grouting. ml 12.00 0.00
6.18 Supply and fix chamfered, bullnose and water dripped 25 x 3cm thick marble edge trim for veranda edge. Price shall include cement sand mortar bed and cement grouting. ml 21.00 0.00
6.19 Supply and fix approved quality 0.8cm thick chip wood ceiling as per the detail drawing and engineers approval. The batten fixing method with steel truss shall be L-shaped or U-shaped steel brackets welded/bolted to the steel truss members. Battens are then nailed or screwed to the brackets. Price shall include 4 x 5 cm suspensions wooden battens with c/c spacing of 600mm both ways, middle and corner list, nails and all the necessary fixing accessories. m2 105.00 0.00
6.20 10 cm thick Concrete pavement around the building bedded on 10 cm thick red ash or fine aggregate and 20cm thick compacted granular materials. The work shall be mixing, placing, compacting, curing, and finishing of concrete with trowel finish while fresh. Price shall include red ash bed, selected fill and trowel finishing work. m2 90.00 0.00
Total Carried to summary USD 0.00
7.1 Supply and fix 0.5cm thick clear glass. Price shall include all the necessary fixing accessories. m2 15.00 0.00
7.2 Supply and fix 0.5cm thick figured glass. Price shall include all the necessary fixing accessories. m2 6.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
8.1 Apply three coats of plastic emulsion paint to internally gypsum plastered wall surfaces. m2 604.00 0.00
8.3 Ditto as item 8.1, but to chip wood ceiling. m2 105.00 0.00
8.3 Apply final acrylic emulsion paint to external rendered wall surface, exposed R.C columns and beams. m2 317.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
TOKER VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.2- Veternary Building-Electrical Installation
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
9 ELECTRICAL WORKS
9.1 uPVC Pipes and Ducts
9.1.1 50mm diameter uPVC m 10.00 0.00
9.2 Earth Network (Grounding System)
9.2.1 Grounding pit 500x500x500mm with top cover inscribed "Grounding pit" as per the detail drawing No 1.00 0.00
9.2.2 Under ground termination network with bare copper cnductor of 1x70sq.mm ml 100.05 0.00
9.2.3 Insulated ground connecting copper cable of 1x70sq.mm ml 30.00 0.00
9.2.4 Earthing electrode diameter 20mm and length 3000mm
Note:If the earth resistence is more than 10 ohms
add additional electrode spaced at length of
the electrode (spaced at a minimum of 5m appart) No 5.00 0.00
9.3 DISTRIBUTION BOARDS
9.3.1 Factory assembled and tested surface-mounted main distribution Board, MDB in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting:
1pc main RCBO of 50A, 3ph , Icu=16KA, 30mA.
1pcs MCB of 32A, 3ph , Icu=10KA
2pcs MCB of 20A, 1ph , Icu=10KA
7pcs MCB of 16A, 1ph , Icu=10KA, coupled with RCD of 30mA. 0.00
8pcs MCB of 16A, 1ph , Icu=10KA
4pcs MCB of 10A, 1ph , Icu=10KA
2pcs MCB of 16A, 1ph (spare) Icu=10KA
1Pc of surge arrestor of 40KA
3 pcs current meters of 50/5A with 6A fuse
1 pc Volt meter of 500V with selector switch and 6A fuse
1 pc frequency meter
with 25% reserve space and busbar of 63A/3ph. No 1.00 0.00
9.4. Feeder Cables and PVC pipes
PVC Sheathed PVC Insulated power cable type NYY 0.6/1KV or equivalent to be drawn inside riser shaft or PVC conduit (measured elsewhere, tentative) and of:-
Cable sizes include: 0.00
9.4.1 5x10 mm2 From utility connection to MDB (Provesional Quantity) m 20.00 0.00
9.4.2 5x10 mm2 From Inverter to MDB m 5.00 0.00
9.5. Light & Switch Points 0.00
9.5.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 46.00 0.00
9.6. Light Fittings and Lamps 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved.
9.6.L1 LED Panel Light: 600x600mm, 22.5W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 6.00 0.00
9.6.L2 LED Panel Light: 300x1200mm, 27W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 8.00 0.00
9.6.L2E LED Panel Light: 300x1200mm, 27W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free, & ~1000 lumens (emergency), 4000K, 90 minute operation, No 3.00 0.00
9.6.L3 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 11.00 0.00
9.6.L4 LED Batten Light:L600mm, CRI > 80, ceiling-mounted, polycarbonate, IP44, flicker-free. No 2.00 0.00
9.6.L5 LED Slim Downlight: 10W, 1100 lumens, 4000K, CRI > 80, polycarbonate, IP44, 220VAC, driver included, No 8.00 0.00
9.6.L6 Mini LED Wall Pack for Toilet Mirror, 10W, 1000 lumens,4000K, CRI > 80, wall-mounted, polycarbonate, IP65 No 3.00 0.00
9.6.(E) Non-maintained LED emergency light (only activates during power failure). Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). Warranty: 3 years (components), 5 years (battery). No 4.00 0.00
9.6(ODL) Over door light bulk head to indicate occupancy of the xray room No 1.00 0.00
9.6. Socket Points 0.00
9.6. 10-16A/1P flush mounted/recessed socket outlets point fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 20.00 0.00
9.9.2 Dito but for Double Outlet No 10.00 0.00
9.7 Power outlet points.
9.7.1. 16A/1P power outlets point for exaust fan and booster pump fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 8.00 0.00
9.7.2 20A/1P power outlets point for split AC fed through PVC insulated conductors of 3x4mm² inside PVC conduits of 19mm inner diameter, including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type-approved. No 2.00 0.00
9.7.3. 32A/3P power outlets point for X-Ray Machine fed through PVC insulated conductors of 5x6 mm² inside PVC conduits of 32mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 1.00 0.00
9.7. Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard.
9.7. Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete.
9.7.1 Single Pole 1-Way Switch No 6.00 0.00
9.7.2 Double pole Switch No 6.00 0.00
9.7.3 Two Way Switch No 6.00 0.00
9.7.4 Two Way Switch Weather proof for outdoor installation No 2.00 0.00
9.7.4 Intermidiate Switch Weather proof for outdoor installation No 1.00 0.00
9.8. Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00
9.8.1 16A ,1ph ,220V 2p+e socket out let No 20.00 0.00
9.8.2 Dito but Double (Twin) Outlet No 10.00 0.00
9.9 Lightning Arrester System
(Eritech or Equivalent)
Shall include all metalic structures in the network with appropriate welding (ventpipes,ducts ,GIS roof & structures, solar PV panels, e.t.c)
9.9.1 Early Streamer Emmision(ESE) Protector SI 25 with mounting mast of H=3.0m and all necessary connecting acessories. No 1.00 0.00
9.9.2 25x3mm copper tape with all necessary roof connecting accessories m 90.00 0.00
9.9.3 25 x 3mm insulated copper tape with vertical supportings every 1m to the wall & all the necessary accessories coordinate the routing of down conductors with the building external skin and architectural features. ml 40.00 0.00
9.9.4 Lightening Event counter to be installed on the down conductor to count number of lightening strikes. No 2.00 0.00
9.9.5 Test point (junction box) with all necessary connection acessories to connect the down conduction with the earthing bare copper wire. at least 1.5m above floor finish. No 2.00 0.00
9.9.6 Prefabricated Crowsfeet 25x3mm tinned coper tape. In complienc with IEC-EN 62561-2, with L1=1000mm and L2= 3000mm No 2.00 0.00
9.9.7 50 x 50 x 50 cm test pit with top cover inscribed "Test pit" as per the detail drawing No 5.00 0.00
9.9.8 1 x 70 sq.mm bare copper wire. ml 10.00 0.00
9.9.9 Diameter 20mm & 3000mm long copper rod. No 2.00 0.00
9.10 DATA\ Telecome System
Tel/Data according to manufacturer’s and utility supplier’s requirements, supplied, installed, connected color coded including tags and tested, complete, all as specified and / or as shown on the drawings
Structured Cabling
Horizontal CAT6A Cabling
9.10.2 Tel/Data and Data/Data points fed through 2x(twisted pair category 6A UTP cable) inside FRLS PVC conduits of 20mm diameter and thickness not less than 1.5mm with conduits accessories (coupling, junction boxes) for tele/Data outlet socket. No 11.00 0.00
9.10.3 Cat 6A 24 port Patch Panel RJ 45 contact No 2.00 0.00
9.10.4 Cat 6A RJ 45 Patch Cord 0.5m, from switch to pantch panels No 48.00 0.00
9.10.5 Cat 6A RJ 45 Patch Cord 3m, from outlets to workstation computers. No 11.00 0.00
Equipment Racking
9.10.6 Wall Mount metallic rack of 15U pivoting cabinet swing 19" steel enclosure with transparent and lockable door, Built-in PDUs (8-10 Outlets, Grounded) and cooling fans. No 1.00 0.00
9.10.7 1U Horizontal Cable Management Bars, 5 Vertical Plastic Hoops with Cover No 3.00 0.00
Information Outlets: Data &Voice
Extra Over Data Socket Outlets with Detachable Frames & Corresponding Box
9.10.8 2 x RJ45 8 Contact CAT6a Socket Outlets No 11.00 0.00
Active components Type CISCO or approved equivalent.
9.10.10 48-port Gigabit Data +2x10G uplink Switch . No 1.00 0.00
9.10.15 Hybrid PBX with 24Analog, with 4 trunk, Extension including Operator Phone No 1.00 0.00
9.10.16 Cat 6A RJ 11 Patch Cord 1m No 24.00 0.00
9.11 FIRE ALARM SYSTEM
9.11.1 Convensional Fire alarm Control Panel, 2 zones Complete with power supply & battery backup. No 1.00 0.00
9.11.2 smoke detector; with Flash Scan and Detector Base, Complete No 10.00 0.00
9.11.4 Fire alarm sounder strobe (RED) No 2.00 0.00
9.11.5 Surface mounted manual break glass push button including back box No 2.00 0.00
9.11.6 Flush Mounted Fire Alarm Points fed in 2 x 1.5sq. mm Fire Alarm cable (SLC-detectors) inside FRLS PVC conduits of 16mm diameter and thickness not less than 1.5mm with conduits accessories (coupling, junction boxes) No 14.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
TOKER VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.3- Veternary Building-Sanitary Installation
CLINIC BLOCK SANITARY WORKS
1.1 SANITARY EQUIPMENET ( FIXTURES ) USD 0.00
1.2 Water Supply Pipes and Valves USD 0.00
1.3 Waste Pipes and Accessories USD 0.00
1.4 HVAC System USD 0.00
1.5 Fire Fighting System USD 0.00
Total Veternary Clinic Building-Sanitary Installation USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 SANITARY EQUIPMENET ( FIXTURES )
All fixtures which are specified below is subject to the owner's / consultant's approval, based on samples, catalogues and brochures presented by the contractor. Unit price shall include all the necessary fixing brackets or hooks and all assistance civil works such as chiseling of walls, floors, beams and etc.
1.1.1 HAND WASH BASIN (ORDINARY)
Supply and fix R.A.K. or Equivalent, hand wash basins made of white glazed vitreious china with REMER/JAQUAR or Equivalent chrome plated cold water tap, pedastal stand ,complete with stop & arrest valves on water inlet pipe. mixing battery plug, chrome plated chain holder, P-smell trap with connection pipe, fittings, all other necessary etc.complete in all respects. Flexible hose to be REMER or Equivalent and should be capable of resisting pressure of 4 bar. P-smell trap should be brass chrome plated with 50mm height of water seal and trap. № 1.00 0.00
a) Size :- length X width (1000mm x 435mm)
1.1.2 Ditto No 1.1.1 but for animal health clinic medical laboratory and surgical purpose each with two bowl. № 2.00 0.00
1.1.3 Ditto No 1.1.1 but for cleaner room № 1.00 0.00
WATER CLOSET (ORDINARY)
1.1.4 Supply and fix wash-down action toilet squatting pans made of white vitreous china, complete with high-level flush cistern, vertical flush pipe connecting the cistern to the squatting pan, and all necessary accessories. The price shall include stop and arrest valves before water inlet; cistern of vitreous china with a capacity of 7 to 9 liters and maximum filling time of 2 minutes, complete with heavy-duty float valve suitable for water pressure up to 4 bar; chrome-plated steel flush valve; heavy-duty flexible pipes rated for a working pressure of 4 bar; and vertical flush pipe of durable corrosion-resistant material (e.g., galvanized steel, stainless steel, or UPVC) connecting the cistern outlet to the pan inlet, complete with necessary bends, brackets, and wall fixings. Where specified, a hygienic flush/bidet connection shall be provided, comprising a flexible hose, handheld spray nozzle, wall bracket, and appropriate isolating valve. № 2.00 0.00
SANITARY WARES FOR PERSONS WITH DISABILITY (PWD)
1.1.5 Supply and install complete set of sanitary wares for physically challenged toilet room fixtures and accessories including: *Vitreous china wc seat with brass or stainless steel hingedheavy duty plastic cover*Vitreous china hand wash basin with lever action faucet with mixer, brass or chrome smell traps and accessories * 6 liters capacity vitreous china cistern with long lever action flushing arm * 5 pieces of stainless steel grab rails (600x35mm) with slip resistant grip and concealed fixings* Blue Folding rails 850mm,760x305mm flush bends,cloth hooks * Stainless steel lever action hinged drop down rail * Color contrasted padded backrest * Automatic hand dryer * Soap Dispenser * Paper Towel Dispenser * Toilet Tissue Dispenser * Alarm Rest Button * Stainless steel Mirror 1000*400mm & all the necessary material to make the toilet functional. The sanitary ware set shall satisfy BS 8300-2 and BS EN 12182. № 1.00 0.00
1.1.6 WET ROOM ACCESSORIES
1.1.6.1 Supply and fix soap holder in white vitreous china of size 150 x 150 mm. Complete with the necessary fixing and other accessories. № 3.00 0.00
1.1.6.2 Supply and fix toilet paper holder from chrome plated brass wall flanged roll with chrome plated fastening screws and other accessories. № 2.00 0.00
1.1.6.3 Supply and fix crystal glass mirrors for toilets hand wash basins for changing rooms and private rooms with copper back protection, including chrome plated brass mirror clips with chrome plated screws and all the necessaary accessories. a) size 500 X 400 mm № 3.00 0.00
1.1.6.4 Supply, fix, test and commission floor drains made of polished steel, complete with P-smell trap /minimum seal depth 75mm/ and all other necessary fittings and accessories. № 4.00 0.00
Total carried to summary USD 0.00
1.2 Water Supply Pipes and Valves
Domestic water pipes shall be in PPR- PN 4 & be fixed to walls, beams or etc… with metal/ compatible straps. Unit price shall include all assistance civil works and necessary fittings such T, bends, Y, reducers Unions and other necessary valves shall be fixed properly as per the manufacturer's instruction and according to where shown on the drawing. Hot water supply shall be properly insulated and external PPR pipe has to be coated All water pipes shall be tested two times the working pressure or 100 meters head, which ever is greater at the expense of the contractor.
1.2.1 Supply and install PPR PN-4 pipes to internal domestic water distribution system pipes as where shown on the drawing. And external pipes shall be coated Complete with all the necessary fittings and accessories. The pipe shall be coated when applied on exposed surfaces
1.2.2 Supply and fix chrome service valves of approved standard before hand wash basins, water closets and other fixtures. Complete with unions, elastic water proofing, hand wheels of normal quality and with all other necessary accessories.
1.2.3 Ditto to item number 1.2.2 approved quality bronze gate valves on internal branch water pipes and pipe inlet to building of the following size and as where shown on the drawing
1.2.4 Supply, Installation, Testing, and Commissioning of Wall/Window Mounted Exhaust Fan: Fan Unit: The exhaust fan shall be a wall or window mounted type, specifically designed for bathroom/ toilet ventilation. Performance: Airflow Capacity: Minimum free air delivery of 200 cubic meters per hour (m³/hr) at 25 Pa static pressure. Sound Level: The maximum sound power level (Lw) shall not exceed 35 dB(A) when measured in accordance with relevant standards. Components & Accessories: The unit shall be complete with all necessary accessories for effective operation, including but not limited to: Multi-speed controller. Integral back-draft shutter. External rain guard/weather louvre. Grille or front cover. All required fixings, gaskets, and seals. Scope of Work: The unit rate shall be inclusive of, but not limited to, the following activities: Supply of the exhaust fan and all specified accessories. Necessary civil works to create or make good the opening, including sealing and making the installation weatherproof. Electrical wiring from the nearest power source, including a dedicated isolation switch, as per electrical codes. Final installation, testing, and commissioning of the system to ensure optimal performance. № 2.00 0.00
Total carried to summary USD 0.00
1.3 Waste & vent Pipes and Accessories
All domestic waste water pipe lines shall be uPVC (PN10) pipes and shall be provided with a minimum slope of 2% towards the outlet. All uPVC pipes and necessary fittings shall be standard quality and be free from damage during storage, construction and etc. Unit price shall include all the necessary assistance civil works, such as excavation cartaway, fixing or hanging to walls, beams or slabs.etc., necessary fittings such as bends, Y, T, etc.
1.3.1 Supply and lay internal uPVC waste according to where shown on the drawings. Complete with all the necessary fittings.
Dia. 50 mm ml 4.00 0.00
1.3.2 Ditto No 1.3.1 for vent pipes with appropriate end cap
1.3.3 FCO(FLOOR CLEAN OUT)
Supply and fix approved quality screw type under slab Clean Out on waste water as where shown on the drawing. Price shall include all the necessary
1.3.4 Animal waste open dith with galvanized steel grate for cattles out door treatment area ml 4.00 0.00
DITCH-: SIZE[mmXmm] = 300 X 300
1.3.5 Dito 1.3.4 but for animal health clinic cattles recovery room treatment area ml 4.00 0.00
DITCH-: SIZE[mmXmm] = 300 X 300
1.3.6 Dito 1.3.4 but for animal health clinic treatment room & X ray rooms.
DITCH-: SIZE[mmXmm] = 300 X 300 ml 8.00 0.00
Total carried to summary USD 0.00
1.40 HVAC System
Supply, installation, testing, and commissioning of HVAC and mechanical ventilation systems for four (4) distinct room types considering high ambient operation temperature of 52 ºC.The items shall be Anti-corrosion treatment for coastal sites, refrigerant pre-charged for up to 15m piping length, Service valves with Schrader ports. The scope of the work include power cabling work from power point to HVAC equipment.
1.4.1 Supply, install, test and commission a complete high ambient split-type air conditioning unit of 1.5 TR (5.3 kW cooling capacity, equivalent to 18,000 BTU/h). The unit shall be inverter type, utilizing R32 or R410A refrigerant (R22 is strictly prohibited), and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 1.3 kW. The system is designed for cooling only and shall be factory-rated for continuous operation in high ambient temperatures up to 52°C. The system shall consist of one (1) wall-mounted indoor evaporator unit and one (1) outdoor condensing unit, complete with all interconnecting refrigerant piping, control wiring, condensate drain line, remote control handset, and all necessary accessories for a complete and functional installation. Indoor Unit (Evaporator): The indoor unit shall be constructed of UV-stabilized ABS plastic with a white finish. It shall include automatic horizontal and vertical swing louvers, a washable antimicrobial pre-filter, and a cross-flow fan designed for silent operation.
Outdoor Unit (Condenser): The outdoor unit shall be an inverter-driven condensing unit with digital inverter (variable speed) compressor, specifically rated for high ambient operation. The unit shall include corrosion-resistant condenser coil and fan motor. Refrigerant Piping: Interconnecting refrigerant piping shall be provided for a distance of not less than 15 meters (49 feet) between the indoor and outdoor units. The piping shall consist of seamless copper tubing, with liquid line of 6.35 mm (1/4 inch) OD and suction line of 12.7 mm (1/2 inch) OD. The suction line shall be insulated with 13 mm (0.5 inch) thick closed-cell elastomeric foam. Control and Operation: The system shall include a wireless infrared remote control handset enabling full functionality. Features shall include LED display with temperature readout, sleep mode, turbo cooling mode, on/off timer (1-24 hours), auto restart after power failure, and self-diagnostic fault code display. Electrical Characteristics: The unit shall have rated load amps (RLA) of approximately 6.0 A, minimum circuit ampacity (MCA) of 8.0 A, and maximum overcurrent protection (MOP) of 15 A. All electrical components shall be rated for 230V / 50Hz supply. Condensate Drain: The unit shall include a condensate drain line of 25 mm (1 inch) nominal diameter PVC pipe, properly trapped and sloped at minimum 1:100 gradient to designated drainage point. Compliance: The equipment shall satisfy conformity with European health and safety standards (IEC 60335-2-40) or equivalent international certification acceptable in Sudan. The Contractor shall submit manufacturer cut sheets and conformity certificates for engineer's approval prior to procurement. Acceptable Brands: Gree, Midea, LG, Carrier, Daikin, or approved equivalent. № 1.00 0.00
1.4.2 Supply, install, test and commission a complete wall-mounted, high ambient exhaust fan for the X-Ray room, designed to provide mechanical extraction of air while maintaining negative pressure and preventing radiation leakage. The fan shall be mounted directly on the exterior wall face over a specially constructed shielded labyrinth penetration through the brick wall. No external ductwork shall be required. The fan shall be centrifugal or axial type,The fan shall deliver a minimum airflow of 150 m³/h (approximately 90 CFM) at static pressure of 100 Pa (10 mmH₂O or 0.4 inches w.g.) rated for continuous operation in high ambient temperatures, and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 0.08 kW (80 Watts) . The system is designed for exhaust-only ventilation (no supply fan) and shall be installed in conjunction with a passive labyrinth intake for fresh air. The system shall consist of one (1) wall-mounted exhaust fan (maximum power: 0.08 kW), one (1) shielded labyrinth penetration constructed through the brick wall, one (1) interior exhaust grille (high-level mounted), one (1) exterior weatherproof louver, one (1) backdraft damper, and all necessary accessories for a complete and functional installation. No ductwork (rigid or flexible) is required between the fan and the room. The Contractor shall construct a shielded labyrinth penetration of "S" or "Z" configuration (offset path) through the 450 mm thick wall. No straight line of sight shall exist from the interior of the X-Ray room to the exterior fan housing or to the outside environment. № 1.00 0.00
1.4.3 Ditto No 1.4.1 but for laboratory room and with cooling capacity of 2.0 TR (7.0 kW cooling capacity, equivalent to 24,000 BTU/h) and maximum power input of 1.80 kW (1,800 Watts) . № 1.00 0.00
1.4.4 Supply, install, test and commission a wall-mounted fresh air supply fan for the Laboratory Room, designed to provide forced filtered(with MERV 8 filter (replaceable type) to filter incoming outdoor air) outdoor air to meet the ventilation requirement. The fan shall be mounted directly on an exterior wall or window, requiring no ductwork. The fan shall be rated for continuous operation in high ambient temperatures up to 52°C, and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 0.1 kW (100 Watts) . Performance Characteristics: The fan shall deliver a minimum airflow of 200 m³/h (approximately 120 CFM) at static pressure of 50 Pa (5 mmH₂O or 0.2 inches w.g.) – lower static pressure is acceptable because no ductwork is attached. Construction: The fan shall be of wall-mounted type, suitable for through-wall or through-window installation. The fan casing shall be constructed of UV-stabilized ABS or galvanized steel with corrosion-resistant coating. The motor shall be sealed type, IP44 minimum (or IP54 for exterior exposure). The fan shall include: Integral backdraft damper (gravity-operated) to prevent reverse airflow when fan is off, Integral insect screen on exterior side,Exterior weatherproof louver (may be integral or separate),Interior grille (may be integral or separate) with manual damper for airflow adjustment, Mounting: The fan shall be mounted on a wall or window frame on one side of the room (e.g., the 4.8 m wall). A circular or rectangular hole shall be cut through the wall or window frame to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. The fan shall be installed level and plumb. № 1.00 0.00
1.4.5 Ditto No 1.4.4 but for exhaust air system designed to maintain negative pressure and remove airborne contaminants from laboratory room and shall deliver a minimum airflow of 500 m³/h (approximately 300 CFM) at static pressure of 50 Pa (5 mmH₂O or 0.2 inches w.g.) – lower static pressure is acceptable because no ductwork is attached. The fan shall consume maximum 0.1 kW (100 W) . Low-Level Mounting: For effective removal of heavier-than-air contaminants (e.g., chemical vapors, dust), the exhaust fan should be mounted low on the wall, approximately 200 mm to 500 mm above finished floor level. The Contractor shall confirm the mounting height with the Engineer prior to installation. Mounting: The fan shall be mounted on the wall opposite the supply fan (e.g., on the opposite 4.8 m wall). A circular or rectangular hole shall be cut through the wall to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. The fan shall be installed level and plumb. № 1.00 0.00
1.4.6 Ditto No 1.4.4 but for tretment room and shall deliver a minimum airflow of 900 m³/h (approximately 530 CFM) at static pressure of 50 Pa (5 mmH₂O), while consuming maximum 0.37 kW (370 W) . № 1.00 0.00
1.4.7 Ditto No 1.4.5 but for tretment room and shall deliver a minimum airflow of 150 m³/h (approximately 90 CFM) at static pressure of 50 Pa (5 mmH₂O), while consuming maximum 0.08 kW (80 W . The fan shall be mounted on the wall opposite the supply fan to achieve cross-ventilation. The fan may be mounted at mid-height (1.5 m AFF) or high level. A circular or rectangular hole shall be cut through the wall to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. № 1.00 0.00
1.4.8 Ditto No 1.4.5 but for a complete exhaust-only ventilation system for the Animal Clinic Isolation Room, designed to deliver a minimum airflow of 1,000 m³/h (approximately 590 CFM) at static pressure of 150 Pa (15 mmH₂O), while consuming maximum 0.2 kW (200 W) maintain negative pressure for containment of airborne pathogens.The fan shall be mounted directly on an exterior wall, requiring no ductwork (or minimal ductwork for distribution). The fan shall be rated for continuous 24/7 operation, and shall operate on a single-phase 230V / 50Hz power supply. № 1.00 0.00
1.4.9 Ditto No 1.4.1 but for electric/battery room and with cooling capacity of 0.85 TR (2.5 kW cooling capacity, equivalent to 8530.36 BTU/h) and maximum power input of 0.60 kW (600 Watts) . № 1.00 0.00
1.4.10 Ditto No 1.4.5 but for a complete exhaust-only ventilation system for the toilet cubicles, designed to deliver a maximum airflow of 300 m³/h (approximately 176.57 CFM) at static pressure of 60 Pa (0.45 mmH₂O), while consuming maximum 0.06 kW (60 W) maintain negative pressure for containment of airborne pathogens.The fan shall be mounted directly on an exterior wall, requiring no ductwork (or minimal ductwork for distribution). The fan shall be rated for continuous 24/7 operation, and shall operate on a single-phase 230V / 50Hz power supply. № 2.00 0.00
1.4.11 Ditto No 1.4.10 but for janitory room. № 1.00 0.00
Total carried to summary USD 0.00
1.50 FIR FIGHTING SYSTEM
4.10 Supply and fix 5kg of ABC type fire extinguisher with metal protection cover as per shown location on the drawing. № 6.00 0.00
4.20 Ditto ( 4.1) but CO2 type for solar electrical control room № 1.00 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
TOKER VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.3 Solar PV Installation
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
Supply, install, test, and commission a roof-mounted solar photovoltaic (PV) system with a total installed capacity of 24.12kWp, complete with battery storage and a three-phase inverter, designed for reliable off-grid operation. The system shall be engineered for a minimum service life of 20 years, and shall include all required components, accessories, protections, and ancillary works necessary to deliver a fully functional and complete installation, consisting of the following:
1 PV Modules Type Longi solar or approved Equivalent
Monocrystalline bifacial module, 670 Wp, efficiency ≈24.8%, Voc ≈54.6 V, Vmpp ≈45.27 V, IEC 61215/61730 certified. 2 rows × 16 modules roof-mounted; Tier-1 quality and high reliability. Type Longi solar or approved Equivalent. No 36.00 0.00
3 Hybrid Inverter Type Huawei or approved equivalent
3-phase hybrid inverter, 25kW output, 2 MPPT (200–1000 V DC), efficiency ≥ 98.4 %. Integrated battery interface & smart monitoring. No 1.00 0.00
4 Battery System, Type Huawei or approved equivalent
Lithium Iron Phosphate (LFP) stack 15 kWh nominal (14.25kWh usable), 600 V DC nominal range (600–980 V) for 3Ph system. Safe chemistry >4000 cycles. stacks 2.00 0.00
5 Battery Control Modules (PCM)
Power Control Module per stack, manages communication and charge/discharge interface to the hybrid inverter. pcs 2.00 0.00
6 DC protection panel
IP65, 1000V DC protection panel (PV Rated) with busbar ≥ array Isc , 63A, earthing terminal, and all associated accessories consisting of:
2pc DC-rated MCB of 25A
2pc DC-rated String isolator of 32A
1pc, PV rated DC SPD, Type II, In ≥ 20KA pcs 1.00 0.00
All components shall be rated for a minimum of 1000 VDC and suitable for photovoltaic applications. pcs 1.00 0.00
7 DC & AC Cabling
Cu XLPE cables rated 1 kV DC/AC; Includes MC4 connectors, lugs, glands, and labels. ≤ 1.5 % V-drop. 0.00
7.1 1x 4mm2 1kv/DC cables, PV string connection ml 75.00
7.2 2x 6mm2 1kv/DC cables, PV string, and from DC protection Panel to Hybrid inverter. ml 15.00 0.00
7.3 2x 10mm2 1kv/DC cables from Hybrid inverter to Battery stacks. ml 10.00 0.00
7.4 5x 10mm2 0.6/1kv AC cables from Hybrid inverter(HIN) to MDB ml 10.00 0.00
8 Monitoring & Communication
Smart Dongle / Gateway (Wi-Fi or Ethernet). Real-time data, alarms, remote monitoring and system analytics. Type Huawei FusionSolar or approved equivalent. set 1.00 0.00
9 Earthing & Lightning Protection
The Solar PV strings shall be bonded to the Early Streamer Emission (ESE) lightning protection roof network using 25 × 3 mm copper tape to ensure effective lightning protection. The PV array structure shall also be bonded to the main earthing network through 70 mm² copper earthing cables, bonding bars, and lightning down conductors. The overall earthing system shall achieve an earth resistance not exceeding 5 Ω. LS 1.00 0.00
10 Installation, Testing & Commissioning
Complete installation of PV array, battery, inverter, wiring, earthing. Includes polarity, insulation, I-V curve, and BMS integration tests, training & handover. LS 1.00 0.00
11 Contingency / Miscellaneous
Spare connectors, cable glands, fasteners, transport, minor site materials. Covers unforeseen adjustments during installation. LS 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
TOKER VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.4-Water Reservior Plat form & Pump Control Switch Room-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A 0.00
B. SUPER-STRUCTURE
1 BLOCK WORK USD 0.00
2 ROOFING USD 0.00
3 METAL WORK USD 0.00
4 STEEL STRUCTURE USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No additional allowance for working space to be considered for measurement. The site clearing area shall be the net built-up area including aprons, open ditch, entrance step and ramp. m2 10.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for the ground floor from the Average Natural Ground Floor Level (A.N.G.F.L.) to a depth not exceeding 150 cm. The volume of excavation shall be measured only over the net built-up area of the building footprint, excluding aprons, open ditches, and ramps. Working allowance: An additional 0.50 m width on each side of the excavation shall be included to allow for proper working space. Reference level (A.N.G.F.L.): The A.N.G.F.L. is defined as the average of the topographic ground levels taken at the building footprint prior to any excavation works, reduced by 20 cm to account for above work item site clearing. m3 3.50 0.00
1.3 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level. Note: measurement shall include 150 cm working space in each side for trench excavation. m3 3.10 0.00
1.4 Back fill under hard core and around the building with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 3.00 0.00
1.5 Back fill around masonry wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 2.00 0.00
1.6 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material. Disposal shall be measured as the net volume arising from the void created by the excavation, less excavated material backfill, filled and wheel spread within site or left stockpiled. m3 8.60 0.00
1.7 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone.only under concrete channel. m2 1.50 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately.
2.1 5 cm thick lean concrete in grade/class C-5 concrete, minimum cement content of 150 kg/m3 :
A. Under ground floor slab m2 6.00 0.00
B. Under masonry foundation wall m2 5.40 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
A. In 20 cm thick slab m2 6.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
To slab edge m2 2.20 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
A. For slab on grade
Dia 10 mm deformed bar Kg 74.04 0.00
Total carried to summary USD 0.00
3.1 50 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 4.28 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
Walls shall be constructed from class 'B' hollow concrete block (H.C.B.). The blocks shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the blocks shall be in such a way that good key for plasterer is obtained on both side.
1.1 Supply and lay 20cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for pointing.Price shall include recessed pointing. m2 9.12 0.00
Total carried to summary USD 0.00
1.1 Supply and fix approved standard pre-painted 0.35mm thick corrugated iron sheet (C.I.S.) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). m2 4.62 0.00
Total carried to summary USD 0.00
3.1 Double-leaf metal door constructed from 40×40×3 mm RHS steel for vertical and horizontal framing, fully welded and braced with similar RHS sections as shown in the Architectural drawings. Door to be infilled with galvanized steel wire mesh 2.5 mm dia. at 25 mm c/c, welded to frame. Include all necessary welding, surface preparation, one coat of primer, and two coats of synthetic enamel paint to all steel surfaces. All work to conform to detailed drawings and relevant standards.
A. Door D1 size 170 x 150 cm. no 1.00 0.00
3.2 Wire mesh covering for pump control switch side walls made of galvanized steel wire mesh 2.5 mm diameter, spaced at 25 mm c/c, fixed securely to RHS structural frame using appropriate clamps or welding as shown on the drawings. The work includes cutting, fitting, welding (where required), surface preparation, one coat of metal primer, and two coats of synthetic enamel paint on all steel members. All materials and workmanship shall comply with the relevant standards and detailed drawings. m2 2.00 0.00
Total carried to summary USD 0.00
4 STEEL STRUCTURE
4.1 Supply, fabricate, assemble, and erect steel structures using RHS and CHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel Structure Column
Steel structure columns are vertical primary load-bearing members, transferring axial loads (and occasionally bending) from trusses to foundations. Since columns are in direct contact with water during cleaning, apply bituminous damp-proof paint at the column base up to a height of 300 mm (30 cm) to prevent corrosion and moisture penetration.
A.1 steel structure column using two RHS sections, 60 × 60 × 3 mm. not welded part single unit. ml 6.90 0.00
B. Steel Structure Column Beam
The beam shall be welded column to column just below the top plate level where truss and column connected. At the end of the beam where there is no steel column. it connected with the existing building it will be fixed with plate at the concrete column/tie beam
B.1 RHS 60 x 60 x 3mm beam ml 6.00 0.00
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards.
C.1 RHS 80 x 60 x 3mm rafter ml 4.00 0.00
D. RHS Purlins 0.00
D.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 100 x 40 x 3mm L= 60mm angle iron. Price include angle iron. ml 5.70 0.00
4.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate size 150 x 150 x 8mm with 4 dia.18 slotted holes for dia. 16 J-bolt No 8.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
TOKER VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.5-Septic Tank & Soak Away Pit-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. Price shall include all working space allowances deemed necessary. m2 25.00 0.00
1.2 Bulk excavation in ordinary soil to a depth not exceeding 150 cm starting from the natural ground level. Note: measurement shall include 25 cm working space for bulk excavation. m3 69.00 0.00
1.3 Ditto but from 150 cm to 300 cm m3 41.00 0.00
1.4 Back fill around retaining wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 27.00 0.00
1.5 Spread coars gravel at the bottom of soak away m3 1.41 0.00
1.6 Ditto as above but spread fine gravel fill between coarse gravel and 0.4 cm average sand fill. m3 0.35 0.00
1.7 Ditto as above but spread 0.4cm average sand fill between fine gravel & 0.2cm diameter fine sand. m3 0.35 0.00
1.8 Ditto as above but spread top layer soak away 0.2cm average fine sand fill. m3 0.55 0.00
1.9 Cart away excavated material from the site as approved by the Engineer. Soil shall be damped more than 1km. m3 115.00 0.00
1.10 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
A) The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube moulds necessary for the purpose and for submitting reports of the tests to the Engineer.
B) Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/ class C-5 concrete, minimum cement content of 150 kg/m3 :
2.1.1 Under septic tank bottom slab m2 13.00 0.00
2.1.2 Unde soak away pit m2 7.60 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In 20 cm thick septic tank bottom slab m2 13.00 0.00
2.2.2 In 20 cm thick septic tank top slab including ring beam m2 10.00 0.00
2.2.3 In 15 cm thick soak away top slab m2 5.00 0.00
2.3 Formwork shall be timbered or steel or a combination of two, sufficient to contain the wet concrete without leakage. Enough to support temporary loading and pressure from placing Compaction or vibration without displacement or appreciable deflection.
2.3.1 To septic tank bottom slab m2 3.20 0.00
2.3.2 To septic tank top slab including ring beam m2 7.00 0.00
2.3.4 To k top slab including ring beam m2 3.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 Bottom Slab
A. Diam 12mm Deformed bar. kg 214.00 0.00
A. Diam 12mm Deformed bar. kg 147.00 0.00
2.4.3 Tie submerged beam
A. Diam 10mm Deformed bar. kg 77.00 0.00
B. Diam 8mm Deformed bar for distribution bar kg 45.00 0.00
2.4.4 Soak away top slab
A. Diam 12mm Deformed bar. kg 75.00 0.00
B. Diam 8mm Deformed bar for distribution bar kg 31.00 0.00
2.10 Allow lump sum amount 60 x 60 cm concrete manhole cover Ls 2.00 0.00
2.11 Supply & fix wooden or equivalent 6,, thick wooden baffle as shown the detail drawing and Engineer’s approval Ls 1.00 0.00
Total carried to summary USD 0.00
3.1 Construct average 60 cm at bottom up to 120 cm & 50 cm thick width thick Basaltic or equivalent stone masonry septic tank retaining foundation wall bedded in cement sand mortar (1:4) below NGL. For septic wall. m3 15.00 0.00
3.2 Ditto as above but 50 cm thick masonry wall for soak away pit m3 9.00 0.00
3.3 Septic tank chamber partition:-Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) with stiffeners bedded and jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. Price shall include plastering m2 2.00 0.00
3.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to internal & external masonry wall surfaces. m2 52.00 0.00
3.5 Ditto as above item but for HCB chamber partition wall. m2 4.00 0.00
3.6 Allow lumps amount of sanitary uPVC work for septic tank inlet, chamber partition and out let pipes to soak away pit. ls 1.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
TOKER VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.6-Cattle Waste Holding Tank
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including 25 cm thick working allowance in each side. m2 21.90 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to an average depth of 150 cm. Note: measurement shall include the net area of the site clearing work. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. m3 32.85 0.00
1.3 Ditto as above item but to a depth above 150 cm but not exceeding 300 cm from reduced ground level. m3 18.61 0.00
1.4 Selected borrow fill around retaining wall with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 24.24 0.00
1.5 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 55.85 0.00
1.6 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described. All works shall be as per the structural general note.
2.1 5 cm thick lean concrete in grade/class C-5, minimum cement content of 150 kg/m3 :
2.1.1 Under bottom holding tank m2 17.00 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In 30 cm thick bottom slab m2 17.00 0.00
2.2.2 In 20 cm thick retaining/shear wall. m2 30.80 0.00
2.2.3 In 20 cm thick suspended top slab m2 11.78 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To bottom slab m2 5.58 0.00
2.3.2 To retaining/shear wall. m2 61.60 0.00
2.3.3 To suspended top slab m2 11.94 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For bottom slab
Dia 12 mm deformed bar Kg 444.00 0.00
2.4.2 For retaining/shear wall
Dia 8 mm deformed bar Kg 89.00 0.00
Dia 12 mm deformed bar Kg 1,025.00 0.00
2.4.3 For floor slab on grade
Dia 8 mm deformed bar Kg 12.00 0.00
Dia 12 mm deformed bar Kg 271.00 0.00
2.5 Internal surfaces of concrete cattle waste holing tank to be thoroughly cleaned and prepared by removing all dirt, laitance, grease, oil, algae, and loose material; all honeycombed, defective, or uneven surfaces to be repaired and made good with approved cement–sand mortar to provide a sound and smooth substrate. Supply and apply a two-component elastomeric cementitious waterproofing coating, potable-water approved, such as Nitocote CM210 or approved equivalent, to floors and walls, strictly in accordance with the manufacturer’s written instructions regarding surface preparation, priming, number of coats, minimum dry film thickness, curing, and protection. All pipe penetrations and exposed services within the tank to be treated with approved bituminous paint or compatible sealing system prior to application of the waterproofing coating. Item to include all materials, labor, tools, equipment, surface preparation, application, testing, protection, and completion of the works. Waterproofing system to be applied by the manufacturer or an approved authorized applicator, providing material and workmanship guarantees to the Employer. m2 38.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
TOKER VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.7-Site Works-Civil
1.1-Hard-scaping USD 0.00
1.2- Soft Scaping USD 0.00
2 Perimeter Fence with Gate USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 Hard-scaping
1.1.1 Clearing and grubbing of existing surface, including removal of vegetation, topsoil, and debris, to a depth of 40 cm and disposal as directed by the Engineer. m2 105.00 0.00
1.1.2 Selected fill to 95% MDD, including watering and rolling as shown the drawing m3 21.00 0.00
1.1.3 Supply, place, spread, water, and compact approved selected gravel material as capping layer to compound surface floor, including leveling, dressing to required camber/slope, and compaction to specified density as per specification and Engineer’s approval. m2 105.00 0.00
1.1.4 Supply and place crushed stone base course (C-4) 10 cm thick, including spreading, watering, and compaction to 95% MDD. m3 17.85 0.00
1.1.5 Supply, lay, and compact 7 cm thick Asphalt Binder Course using approved bituminous mix, laid in well-prepared and compacted layers over an approved base, in accordance with specifications and Engineer’s instructions. m2 105.00 0.00
1.1.6 Edge restraint using concrete curb (15 × 40 cm) including excavation, formwork, placing, and finishing. ml 45.00 0.00
1.1.7 Supply and install resin bound gravel surface comprising washed and dried natural aggregates mixed with UV-stable polyurethane resin, laid to specified thickness over a prepared and approved base, including finishing to a smooth, permeable, and durable surface in accordance with the specifications and Engineer’s instructions. m2 105.00 0.00
Total Carried to Summary (USD) 0.00
1.2 Soft-soaping
1.2.1 Clearing and grubbing of existing surface, including removal of vegetation, topsoil, and debris, to a depth of 60 cm and disposal as directed by the Engineer. m3 37.80 0.00
1.2.2 Supply, place, spread, water, and lightly compact approved loamy (loam) soil for soft landscaping works, free from stones larger than 20 mm, roots, debris, weeds, and other deleterious materials, and suitable for plant growth. Loam soil shall have good drainage and adequate organic content, as approved by the Engineer. The rate shall include supply of soil, transportation, placement to the required levels and thicknesses, watering, light compaction, trimming, leveling, and all labor, tools, and equipment necessary to complete the work as specified. avg. depth 300mm m3 18.90 0.00
1.2.3 Supply, well decomposed animal manure or equivalent organic material to be mixed with the topsoil averagely 300mm and to use in backfilling of planting pits. Price shall include all the necessary works to complete the work. Provide 1kg sample and details of supplier With quotation for Landscape Architect’s approval. m3 18.90 0.00
1.2.4 Provide and plant grass as selected by the landscape architect. price includes grass as per the detail Architectural drawing. m2 63.00 0.00
1.2.5 Maintenance of lawn , grass, trees, shrubs, seasonal flower bed, other plantation and horticultural operations for weeding, watering, spreading of manure, good earth , fertilizers, spray of insecticides, fungicides, hoeing, pruning of tree/shrubs/hedge plants grassing garden swords, anti-termite treatment. Rates to include cost of material, all labor, tools & tackles, cost of manure, earth, fertilizer, pesticides etc. and also providing complete arrangement at site/sites for grass cutting by brand new power run lawn mower with skilled machine man & labor, diesel, lubricant to ensure mowing on barns and by manual labor through garden sward on the slop of under pass of the grass at least 3 times / month complete Month 2.00 0.00
1.2.6 Provide plants specially selected and nursery grown shade trees. Price supply of plants and planting as per the detail Architectural drawing. No 11.00 0.00
Total Carried to Summary (USD) 0.00
2 Galvanized Steel Wire Mesh Perimeter Fence with Gate
2.1 Supply, fabricate, and install galvanized steel wire mesh perimeter fence comprising 60 × 60 × 3 mm RHS vertical posts spaced at 2500 mm centers, fixed in concrete pad foundations, with top and bottom horizontal rails (60 × 60 × 3 mm RHS). The fence infill to be galvanized steel wire mesh (Ø 2.5 mm, 25 × 25 mm grid) securely fixed to the frame.The rate shall include excavation, concrete works, anti-rust treatment, metal painting, and provision of a main gate (2700 mm width) fabricated from similar materials, complete with all accessories, in accordance with specifications and Engineer’s instructions. ml 90.00 0.00
Total Carried to Summary (USD) 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
TOKER VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.8-Site Works-Electrical
ITEM DESCRIPTION UNIT QTY RATE TOTAL
1 Manhole for Electrical Systems
. Construct rectangular double red burnt brick electrical manholes of internal dimensions 800mm × 800mm × 700mm in accordance with the detail drawings and specifications. The manhole shall comprise 250mm thick double red burnt brick masonry walls, internally plastered with cement-sand mortar, a 100mm thick reinforced concrete base slab, and a 100mm thick removable reinforced concrete cover slab complete with flush-type cover, all as approved by the Engineer. The rate shall include excavation to the required depth, disposal/cart-away of surplus excavated material, back-filling and compaction around the structure, supply and placement of concrete, reinforcement, form-work, brick masonry, plastering, curing, and all associated civil works, labor, materials, tools, and incidentals necessary for the complete and proper construction and functioning of the electrical manhole system. Set 7.00 0.00
2 Light Fittings and Lamps 0.00
. Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing. IEC 60969 standards or equivalent and type approved 0.00
LED Solar Street Lights for Outdoor, atleast 15000 Lumens DA high-brightness, all-in-one solar street light for perimeter lighting, powered by sunlight with no electricity costs. Key Specifications Brightness: ≥15,000 lumens (bright as daylight) Light Type: LED (SMD 2835 or CREE 3030 chips) Color: Cool white (6000K–6500K) Solar Panel: 150-watt monocrystalline (charges in 6 hours) Battery: LiFePO4, ≥7-year lifespan, 3-day backup capacity. Operation: Dusk-to-dawn (auto on/off with daylight sensor) Motion sensor (full brightness on movement, dims to save energy) Remote control (adjust brightness, set timers) Weatherproof: IP65 (waterproof, dustproof, works in rain or heat) Material: Aluminum housing, tempered glass cover Runtime: 11 hours after 6-hour charge; up to 18 hours in dim mode Installation: Pole or wall mount (6ms height), no wiring needed Durability: Works in -22°F to 140°F; 50,000+ hour lifespan Warranty: 3–5 years No 8.00 0.00
3 Documentation 0.00
. Engineering, electrical installation as built drawings and O&M manuals. Qualified Set 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
TOKER VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.9-Site Works-Sanitary
SITE SANITARY WORKS
1 SITE WATER SUPPLY SYSTEMS USD 0.00
2 SITE WASTE WATER DRAINAGE SYSTEMS USD 0.00
3 ROOF & SURFACE RAIN WATER DRAINAGE SYSTEM USD 0.00
4 GENERAL ITEMS USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 WATER SUPPLY SYSTEMS
1.1 Site Water Supply Piping Systems
1.1.1 Supply,laying and test Cold drinking water pipes from municipality line to ground water tank(GWT). The pipe shall be PN16 DN50 High Density Polyethylene (HDPE) made of pure PE 100 rawmaterial and be laid in trench as shown in the sanitary site drawing. Provide 100mm thick sand bedding material rammed and tamped and 150mm thick approved material to cover the pipe all as per the typical site trench section and detail.Unit price shall include excavation, backfilling and cart away the excess quantity with all assistance civil works and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 10.00 0.00
1.1.2 Supply,laying and test Cold drinking water pipes from ground water tank(GWT) to transfer pump and to elevated water tank(EWT). The pipe shall be PN16 DN32 High Density Polyethylene (HDPE) made of pure PE 100 rawmaterial and be laid in trench as shown in the sanitary site drawing. Provide 100mm thick sand bedding material rammed and tamped and 150mm thick approved material to cover the pipe all as per the typical site trench section and detail.Unit price shall include excavation, backfilling and cart away the excess quantity with all assistance civil works and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 12.00 0.00
1.1.3 Supply,laying and test Cold drinking water pipes from gelevated water tank(EWT) to building block entrance where branched to water points (usable water supply)and nearby drainage lines (for overflow & washout piping). The pipe shall be PN10 DN40 PPR made of pure original rawmaterial and be laid in trench as shown in the sanitary site drawing. The unit price shall include piping bottom drain with valves piping system from EWT connected with overflow and connected to near by drainage ditch, air vent with insect screen and all support fixting work with related civil works. The unit price shall also consider and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 20.00 0.00
1.2 Supply and fix chrome service valves/isolation valve of approved standard before wet areas, or hand wash basins, water closets and other fixtures. Complete with unions, elastic water proofing, hand wheels of normal quality and with all other necessary accessories.
1.3 Construct standard a double brick wall,R.C base slab & R.C cover valve chamber compatible to valve size at specific position shown on the drawing with the respective PN6 bronze isolating valve.The price shall include excavation of a pit, cart away and backfilling.
1.3.1 Valve chamber with DN : variable isolation valves. № 4.00 0.00
1.4 Supply, installation, testing, and commissioning of domestic cold-water meter of multi-jet or volumetric type, suitable for potable water application in the animal health clinic water distribution system, complying with ISO 4064 / OIML R49 standards.Water meter shall be of DN50 nominal size, with brass or epoxy-coated ductile iron body, sealed dry dial register, and corrosion-resistant internal components. The meter shall be Class B or R80 accuracy, with a nominal working pressure of 16 bar, and maximum temperature 30°C.Each meter shall include couplings, strainer, and non-return valve, islation valve at each end and be installed in an accessible, ventilated, and protected meter chamber.All meters shall be factory-calibrated, certified, and permanently marked with serial number, flow class, size, and manufacturer identification. № 1.00 0.00
1.4 Water Reservoirs
1.4.1 Elevated water tank[EWT]
Supply, install, and commission a high-quality fiberglass (or equivalent) water tank with a nominal capacity of 2,500 liters for potable water storage, elevated 6 meters above ground on a support structure as per the provided sanitary and structural detail drawings. Tank Specifications: Material: Fiberglass reinforced plastic (FRP) or equivalent, approved for potable water storage, compliant with relevant standards ( BS EN 13280 or equivalent). Capacity: 2,500 liters (nominal). Design: Vertical seated(bottom diameter < 2m , suitable for external exposure with UV-resistant coating to withstand harsh weather conditions. Accessories: Manhole: Watertight manhole (minimum 600 mm diameter) with a lockable, weather-resistant cover to prevent contamination and ensure safety. Overflow Pipe: Minimum DN50, directed to a near by rain water drainage point with insect-proof mesh. Level Sensor: Automatic water level sensor/controller to start/stop the transfer pump. Inlet Pipe: Minimum DN32, fitted with a PN16 bronze gate valve. Outlet Pipe: Minimum DN40, fitted with a PN16 bronze gate valve and an expansion joint to accommodate to absorb any pipe movement. Drain Pipe: Minimum DN50, fitted with a PN16 bronze gate valve for complete tank drainage, directed to a designated drainage point. Fittings: All pipes and fittings shall be corrosion-resistant, suitable for potable water, and compliant with relevant standards (BS EN 545 or equivalent). Set 1.00 0.00
1.4.2 Ground water tank[GWT]
Supply, install, and commission a high-quality fiberglass (or equivalent) water tank with a nominal capacity of 5000 liters for potable water storage, at ground level as per the provided sanitary and structural detail drawings. Tank Specifications: Material: Fiberglass reinforced plastic (FRP) or equivalent, approved for potable water storage, compliant with relevant standards ( BS EN 13280 or equivalent). Capacity: 5000 liters (nominal). Design: Vertical seated(bottom diameter < 2m , suitable for external exposure with UV-resistant coating to withstand harsh weather conditions. Accessories: Manhole: Watertight manhole (minimum 600 mm diameter) with a lockable, weather-resistant cover to prevent contamination and ensure safety. Overflow Pipe: Minimum DN50, directed to a near by rain water drainage point with insect-proof mesh. Level Sensor: Automatic water level sensor/controller to start/stop the transfer pump. Inlet Pipe: Minimum DN50, fitted with a PN16 bronze gate valve. Outlet Pipe: Minimum DN32, fitted with a PN16 bronze gate valve and an expansion joint to accommodate to absorb any pipe movement. Drain Pipe: Minimum DN50, fitted with a PN16 bronze gate valve for complete tank drainage, directed to a designated drainage point. Fittings: All pipes and fittings shall be corrosion-resistant, suitable for potable water, and compliant with relevant standards (BS EN 545 or equivalent). set 1.00 0.00
1.5 Potable Cold Water Pumping system
1.5.1 Supply, fix, test and commission approved quality duplex vertical inline water pumps to push potable water to elevated water tanks to be distributed to every demanding buildings of the compound .As per the manufacturer's instruction and drawing shown . Price shall include all the necessary valves( one-way and stop valves), water hammer arrestor , common base plate ,automatic level control sensors & switches to start/off & to protect pumps from dry running & control panel .The price shall include all the necessary accessories required for the proper operation of the system but not specified or shown on the drawing. The pump shall be equiped with a single-phase transfer pump control board to manage water levels in an elevated water tank and ground water tank, featuring a compact IP65-rated enclosure (stainless steel or powder-coated mild steel), industrial-grade PLC, 4-inch touchscreen HMI for real-time monitoring and manual override, ultrasonic or float-type level sensors (2 nos. per tank) for accurate water level detection, control logic for automatic pump start/stop based on setpoints with sequential operation to minimize load, thermal overload relays, dry run protection via sensors or current monitoring, single-phase failure protection, surge arrestors, flame-retardant copper wiring, dedicated earthing, real-time pump status and alarm monitoring (high/low water levels, pump faults) on HMI, compliant with IEC standards and local regulations, complete with installation, testing, as-built drawings, operation manuals, training, and a 2-year warranty, designed for a 10-year operational life. Flow rate[LPS] = 0.694 @ 10 meter head Reference Model : Brand: DAB Model:KLPE 40-1200 with respective control systems and sensors. Set 1.00 0.00
1.5.2 SUPPLY, INSTALL, TEST & COMMISSION MUNICIPAL WATER CONNECTION TO GROUND WATER TANK Scope includes but not limited to: • Supply and installation of HDPE PE100 PN16 DN50 pipe (maximum 20 m total trench length from municipal main to groundwater tank inlet). • Supply and installation of municipality-approved water meter (DN50, with calibration certificate and serial number registration). • Supply and installation of isolation valve (gate/ball type, PN16, DN50, with flange or compression ends). • Supply and installation of all necessary fittings (elbows, tees, reducers, flanges, couplings, anchor blocks, thrust blocks, gaskets, bolts, and nuts). • Supply and installation of above-ground fence enclosure (galvanized steel or powder-coated mild steel) around the meter & valve assembly, with lockable access door, minimum 1.2 m height. • Excavation, backfilling, and compaction of trench (depth as per local municipality code, including sand bedding and warning tape). • Connection to municipal main (including tapping, saddle, or tee as required) and connection to tank inlet (with appropriate adapter). • Pressure testing (1.5x working pressure for minimum 24 hour), flushing, and chlorination/disinfection of pipeline. • All civil works (concrete pads for meter/fence posts, gravel base, and surface restoration to original condition). • All permits, inspections, and approvals from the local municipality (including meter registration and final sign-off). • As-built drawings and operation/maintenance manuals submission. Note: All materials shall be new, certified, and compliant with municipality standards. Contractor to verify all site dimensions and municipal point of connection prior to execution. ls 1.00 0.00
Total Carried to summary USD 0.00
2 WASTE WATER DRAINAGE SYSTEMS
2.1 Providing, laying and jointing of internal uPVC PN-10 waste pipes with all uPVC pipe fittings including jointing with solvent cement joints and testing of joints etc. according to where shown on the drawings.Complete with all the necessary fittings. Provide cleaning detail for all waste water riser pipes as per the detail drawing.
2.1.2 Diameter 110mm ml 14.00 0.00
2.1.3 Diameter 160mm ml 37.00 0.00
2.1.3 Diameter 300mm ml 14.00 0.00
2.1.4 Construct rectangular manhole out of 250mm thick double brick walls,internal dimension 600mm x 600mm x 850mm (average depth),internally plastered with three coats of cement/sand mix ratio1:3 ,on a base of precast R.C slab of size ,1300mm x 1300mm x100mm , including benching and bottom channeling with mass concrete.Slab shall be reinforced with dia.8mm reinforcement bar c/c 130mm bothways. Provide 150mm thick granular materials beneath the slab,on a compacted earth . Manhole shall have precast R.C cover slab, each,size, 740mm x 740mm x 100mmreinforced with diameter 8mm steel barc/c140mm bothways,including diameter 14mm steel ring handle with supporter bar all in accordance with the given detail drawings .Unit price shall include excavation of the pitto a depth of 800mm (average) and cart away of the excavated soil. № 8.00 0.00
2.1.5 Ditto No 2.1.4 but size(length x width x depth)[mm]= 400 x 400 x 400 gully trap for gray water drainage № 3.00 0.00
Total Carried to summary USD 0.00
3 ROOF WATER DRAINAGE SYSTEM
3.10 Construct a rectangular open channel designed to collect and convey storm water runoff from around the building perimeter. The channel is made of 20cm thick masonry bed, 40cm thick side masonry wall and whenever the walk way, ramp and car way crossing the top part will be covered with pre case concrete cover. The internal part of the channel shall be plastered. The work shall include excavation, cart away , fill, masonry bed, wall, plastering , pre-cast concrete cover at crossing and all incidental work to complete work as per the project’s detailed drawings. The channel longitudinal slope of 1% (1:100) shall be maintained. Where the natural ground slope exceeds 1%, the contractor shall follow the greater natural ground slope to ensure positive drainage and avoid ponding. ml 90.00 0.00
Minimum Ditch-: SIZE[mmXmm] = 225 X 200
3.20 Ditto No 2.1.3 but for roof and surface water drainage system. № 10.00 0.00
3.30 Ditto No 2.1.4 but for roof and surface water drainage system. № 2.00 0.00
3.40 SURFACE WATER DRAINAGE CONNECTION TO ROADSIDE DRAINAGE LINE Scope includes but is not limited to: • Supply and installation of DN300 uPVC pipe (Class/SN as per local municipality standard for underground non-pressure drainage) from the manhole inside the clinic compound to the roadside drainage line. Total length to be verified on-site. • Pipe shall be laid at a gradient of 0.5% to 1% (1 in 200 to 1 in 100) to ensure self-cleansing velocity and prevent siltation. • Connection to existing manhole inside clinic compound (600mm x 600mm internal size, with invert level above road side drainage invert). Includes breaking into manhole wall, making good, and providing a proper connection. • Connection to roadside drainage line (standard road side channel/drain). Includes forming a proper junction at the outfall point. The connecting pipe's invert level shall be set above the soffit (crown) of the roadside drain to prevent backflow during high-flow conditions in the main drain. • Supply and installation of all necessary fittings (bends, junctions, couplings, adaptors) as required for directional changes and connections. • All civil works: Excavation (including breaking existing surfaces), trenching, pipe bedding (sand/gravel), backfilling, compaction, and surface restoration to original condition. • Testing of the installed pipeline by means of water or air testing to ensure leak-tightness prior to backfilling. • All necessary permits, approvals, and inspections as required by the local municipality for connection to the public drainage system. Note: Contractor to verify all site levels, invert levels of the existing manhole and roadside drain, and confirm the required slope is achievable before commencement. All works to be carried out as per local municipality standards and approved drawings. ls 1.00 0.00
Total carried to summary USD 0.00
4 GENERAL ITEMS
4.1 Allow for Testing and commissioning of the entire plumbing installation by a Chartered Mechanical Engineer and obtaining a Test Certificate (3rd party testing to approval of the Engineer) including all off-site and factory testing; inspections to demonstrate compliance with relevant standards, operating the completed installation and submitting all relevant test records and authority approval. LS 1.00 0.00
4.2 All sanitary fittings supplied shall be provided with a minimum 5 year warranty, issued jointly and severally by the local supplier and the manufacturer. LS 1.00 0.00
4.3 Allow for preparation of Operationa and Maintenance Manual including site users training for the O & M Maual of all plumbing and mechanical appliances. LS 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
TOKER VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bill No.10-Signage
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 Directory Signs
Design, supply and install international standard Boy's, Girl's & PWD Toilet directional sign complete with pictogram (Girl's, Girl's & PWD toilet sign symbol) plus directional arrow that leading to the toilets. The sign shall also consist text “Boy's , Girl's & PWDToilet.” Sign shall be minimum size 300 mm × 400 mm, high quality tin: tin sign with retro design, metal tin, long-term use, not easy to damage, smooth surface, ...with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 1.00 0.00
2 Room Identication Signs
Design and supply signage with room number in accordance with this specification and as directed by the Architect. The material shall be made of 3-5mm thick wall mounted Acrylic signs. The size shall be 250mm x 30mm and letter height shall be 50-70mm for room number, 25-40mm room name letters and braille and tactile characters where applicable. The color and contrast between the text and background shall be high and the color shall be consistent with the veternary clinic branding (if any) or as per the Architect approval. The topography and information shall be Room number: Bold, large font (sans serif preferred), Room function/name: Smaller font beneath the number (e.g., Room 101 – Office) and Braille/tactile lettering placed below the printed text. The signage shall be fixed to the wall at 1.4–1.5 m above floor to centerline of sign on the latch side of the door, or directly on the door if wall space is not available and it shall be fixed with secure concealed fasteners or adhesive (depending on wall/door material). The supplier shall produce and submit Mock-ups for approval before mass production. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect.
2.1 Isolation Room No 1.00 0.00
2.2 Office No 1.00 0.00
2.3 X-ray room No 1.00 0.00
2.4 Preparation room No 1.00 0.00
2.5 Electric Room No 1.00 0.00
2.6 Rest rooms and Janitors with pictogram of gents, ladies and PWD No 4.00 0.00
2.7 Treatment room No 1.00 0.00
2.8 laboratory No 1.00 0.00
3 Safety and Compliance Signs
4.1 Design, supply and install Emergency Exit Sign in accordance with this specification and as directed by the Architect. The material shall be made of flame-retardant, impact-resistant ABS clear acrylic plate and shall comply with BS EN ISO 7010 Exit Symbol (E001) and shall have Multi-installation system: Hanging, wall or surface mounted depending on the location. The size of the letter height shall be minimum 150mm with a stroke width 19mm, color contrast to be white letters on green background and the sign shall consist pictogram of running man symbol + directional arrow that leading to exit doors depending the location of the Emergency sign plan on the drawing. The sign shall support internally illuminated and visible in smoke and low light and are powered by dual power 220-240V AC (primary), automatic 90 minutes minimum battery backup (Lithium-ion battery).The sign shall be fixed to exist access point at 2.00–2.50 m above floor level. The supplier shall produce and submit Mock-ups for approval before mass production or procurement. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect. No 4.00 0.00
4.2 Design, supply and install Entrance Sign in accordance with this specification and as directed by the Architect. The material shall be made of flame-retardant, impact-resistant ABS clear acrylic plate and shall comply with BS EN ISO 7010 Exit Symbol (E001) and shall have Multi-installation system: Hanging, wall or surface mounted depending on the location. The size of the letter height shall be minimum 150mm with a stroke width 19mm, color contrast to be white letters on green background and the sign shall consist text+ directional arrow that leading to entrance.The sign shall be fixed to entrance access point at 2.00–2.50 m above floor level. The supplier shall produce and submit Mock-ups for approval before mass production or procurement. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect. No 3.00 0.00
4.3 Supply and fix 3mm rigid PVC/acrylic Fire Extinguisher sign (300mm x 100mm) with 50mm high ISO-compliant white lettering on red background, including all fixings and installation. No 7.00 0.00
4.4 Supply directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. Supply and install directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. No 1.00 0.00
4.5 Supply emergency assembly point safety sign complete with standard ISO 7010 pictogram (E007: four people symbol) and text “EMERGENCY ASSEMBLY POINT.” Sign shall be fabricated from 3 mm thick photo luminescent rigid PVC or aluminum composite panel, minimum size 600 mm × 600 mm, with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
TOKER VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.10-Day Works
1 LABOUR USD 0.00
2 MATERIAL USD 0.00
3 PLANT USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
(ALL PROVISIONAL)
In accordance with the Conditions of Contract, the Contractor will be paid day work rates for extra work that cannot properly be measured and valued, and the Contractor is to insert in the space provided below the basic rates and costs of labour,materials and plant as described hereunder:-
1.1 MASON hours 1 0.00
1.2 CARPENTER hours 1 0.00
1.3 SCAFFOLDER hours 1 0.00
1.4 JOINER hours 1 0.00
1.5 PLUMBER hours 1 0.00
1.6 ELECTRICIAN hours 1 0.00
1.7 PLASTERER hours 1 0.00
1.8 PAINTER hours 1 0.00
1.9 LABOURER hours 1 0.00
TOTAL in USD 0.00
1.10 To the basic net rates of labor used for work carried out on day works, an addition 25% percent which is to include for task work and incentive schemes, tools, standing, scaffolding, supervision, insurance, transport profit and overheads.
To collection of Labour Day works 0.00
2.1 Cement Per Tonne 1 0.00
2.3 Aggregate (grade 25 - 5mm) m3 14 0.00
2.4 Steel reinforcement
(i) Mild steel bar Kg 1 0.00
(ii) High tensile bar Kg 1 0.00
2.5 Timber formwork Per SQ.M 1 0.00
2.6 Paint, Gloss Per 4 Litres 1 0.00
2.7 Paint, Emulsion Per 4 Litres 1 0.00
2.8 Mahogany Varnish Per 4 Litres 1 0.00
2.9 100mm diameter uPVC rainwater downpipe 6M Per Each 1 0.00
2.10 Ditto bends Per Each 1 0.00
2.11 Ditto offsets Per Each 1 0.00
2.12 Ditto watershoe Per Each 1 0.00
2.13 Fixing brackets Per Each 1 0.00
2.14 Fixing screws Per Packet 1 0.00
2.15 75mm thick x 375mm wide weather/throated cills Per M 1 0.00
2.16 4 mm Clear sheet glass Per SQ.M. 1 0.00
2.17 100mm long Flush bolt Per Each 1 0.00
2.18 Indicator Signage Per Each 1 0.00
2.19 400mm x 200mm x 100mm hollow concrete blocks Per 1000 1 0.00
2.20 300mm x300mm x 8mm Ceramic floor tiles Per SQ.M. 1 0.00
2.21 150mm x 150mm x 6mm white glazed wall tiles Per SQ.M. 1 0.00
2.22 25mm x 3mm earth copper tape Per M 1 0.00
2.23 35mmsq bare copper cable Per M 1 0.00
2.24 6mmsq bare copper cable Per M 1 0.00
2.25 2.5mmsq. TWE copper cable Per M 1 0.00
2.26 2.5mmsq. SC PVC-I copper cable Per M 1 0.00
2.27 4.0mmsq. SC PVC-I copper cable Per M 1 0.00
2.28 10.0mmsq. 3C PVC-SWA-PVC copper cable Per M 1 0.00
2.29 20mm diameter galvanised steel tubing 6M Per M 1 0.00
2.30 20mm diameter galvanised steel tee Per Each 1 0.00
2.31 20-15mm diameter reducer Per Each 1 0.00
2.32 110mm diameter uPVC soil pipe 6M Per Each 1 0.00
2.33 50mm ditto waste pipe 6M Per Each 1 0.00
2.34 110mm ditto single branch access Per Each 1 0.00
2.35 50mm ditto sweep tee Per Each 1 0.00
2.36 Single bowl, single drainer stainless steel sink size 2000 x 600mm Per Each 1 0.00
To Collection 0.00
2.37 To the basic nett rates of materials used for work carried out on dayworks, an addition of 25% which is to include for unloading and storing as necessary, the use of hand plant, and machinery etc. available on site, profit and overheads.
To collection of Material Day works 0.00
3.1 Portable Compressor with 2 breakers or equivalent with 1500 mm hoses and reels hours 40 0.00
3.2 Damp Truck (0.75 tonne) hours 40 0.00
3.3 Lorry seven tonne tipper hours 40 0.00
3.4 Concrete Mixer (14/10) complete for weight batch mixing hours 40 0.00
3.5 50 mm self priming centrifugal pump with hose and ancillary equipment hours 40 0.00
3.6 Concrete Vibrators hours 40 0.00
To Collection 0.00
3.7 To the basic rates of plant used for work carried out on dayworks, an addition of 25% per cent, which is to include for driver and/or attendance, fuel and consumable stores supervision, insurance, road licence,profit and overheads.
To collection of Plant Day works 0.00
Name of Signatory:
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Exavation Work
ITEM TYPE SIZE No M3
Exavation & Earthwork
1.01 site clear
cad area including appron,ditch
1.02. Bulk Excavation to reduce level
1.03. Footing Excavation
1.04. ditto but from 1.50-3.00m
1.05.Trench Excavation
with 0.15 allowance each side
1.05. Back fill under hard core
ddt stone masonry wall
1.06.Ditto but around footing
Excavation Volume
ddt lean concrete
ddt footing pad
ddt column 0.00
1.07.Ditto but around masonry
with 0.25 allowance each side
1.08. Cart away
1.09. hard core
1.10. Dewatering
3.01. construction joint
10mm thich joint filler/sila or fiber board
4. Masonry Item
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Sub-Structure Concrete
CONCRETE FORM WORK
Type Size No Total Size Total
2.1. Lean Concrete
Total 118.86 m2
Under masonry wall
Under hard core
2.2 C -25 CONCRETE
Foundation Column
Total 5.04 67.20
200mm thick slab
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Super-Structure Concrete
CONCRETE FORM WORK
1.1. C-250 Concrete
A. Elevation Column
From Ground-roof floor
150mm Concrete gutter
Total 9.05 m3 129.05 m2
100mmSun breaker
Total 22.11 m3 23.32 m2
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Architectural
ITEM TYPE SIZE No Total
2.01. 20cm thick H.C.B wall screening
2.01. 20cm thick H.C.B wall
ddt opening 0.00
3. Roofing Work
3.04. Valley gutter
Gutter light wt concrete
Gutter water proofing
B. Steel Structure Beam
C. RHS Truss system
C.1 RHS 60 x 60 x 3mm upper and lower member
Total length 188.60
Unit Wt. for the section 5.37
Total Kg 1,012.67
C.2 RHS 50 x 50 x 3mm upper and lower member
Total length 24.00
Unit Wt. for the section 4.43
Total Kg 106.26
C.3 RHS 40 x 40 x 3mm Diagonal & verical member
Total length 181.85
Unit Wt. for the section 3.49
Total Kg 633.82
D.1 80 x 4 x 3mm fixed
Total length 434.10
Unit Wt. for the section 5.37
Total Kg 2,330.86
Base plate 200 x 200 x 6mm
Total plate 56.00
7. Finishing work
6.0 Two coats of plastering
Internal HCB wall plastering
to receive gypsum chuck
ddt opening 0.00
External plastering
ddt opening 0.00
Bill No.2 Staff Residence Block
For Ariya kayisa Primary School
Summary of Reinforcement for Sub-structures & Super-Srructure
Foundation Footing
Foundation Column
Ground Floor Beam
Ground Floor Slab
Super-Structure
Elevation Column
REINFORCING BAR SCHEDULE
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Date , Sep 28,2025
Bill No.-2-Staff Residence Block Consultant;- UNOPS-ETMCO
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Foundation Colum --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Foundation Column --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Ground floor slab --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
internal partiton area --- --- --- --- --- --- --- ---
REINFORCING BAR SCHEDULE
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Date , Sep 28,2025
Bill No.-2-Staff Residence Block Consultant;- UNOPS-ETMCO
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Elevation Column --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
United Nations Office for Project Services
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
Tender Reference:
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR),
CONSTRUCTION WORKS FOR VETERNARY PROJECT
BILL OF QUANTITIES (BOQ)
- Bill Nr.1 - Mobilization
- Bill Nr.2 to 10-Civil, Electrical & Sanitary Works-BoQ
- Bill Nr.11 - Day Works
NOTE: It is a MANDATORY requirement for bidders to complete and return both this excel BOQs and their respective duly signed pdf for further reference
Failure to complete all sections of the BOQ may result to automatic disqualification of your bid.
PREAMBLE TO BILLS OF QUANTITIES
1 Priliminary Condition
1.1 This Specification shall be read in conjunction with the Particular Technical Specifications provided under each work discipline, as well as the latest edition of the Sudan Standard Technical Specifications for Building Works, or any other internationally recognized standards commonly adopted in Sudan.
1.2 The Bill of Quantities (BoQ) shall be measured in accordance with the latest edition of the Sudan Standard Methods of Measurement for Building Works.Pro Memoria (PM): Indicates that the cost of the item is deemed to be included and distributed within other related work items in the BoQ. No separate payment will be made.Lump Sum (LS): Indicates that the item is priced as a fixed total amount, with no adjustment or variation permitted to the total price regardless of actual quantities executed.
1.3 The contractor has fully understood the scope of works by minutely having studied the drawings and Bill of Quantities with specifications, and by having visited the site. He will, on his own initiative and before the works start and in his best ability, notify the consultant of works which are not mentioned in the BoQ and/or the specifications and/or the drawings, which are necessary to execute the construction as envisioned in the drawings. Thus, after the works have started, the contractor cannot rely on incompletions in the consultants' work to make claims of any kind. Indeed, the contractor will add upon the specifications according to his own insight and professional experience. If there are works to be done which are not specified in this BoQ, it is up to the consultant to decide wether these works are variation works which need change orders, or wether these works are included in the items and their prices in the BoQ.
1.4 The contractor has to execute all works which have a direct or indirect impact on safety and availability of infrastructure (water, sewage, electricity, …) in as short a period as feasible.
1.5 The contractor will secure the structural and functional integrity of the exsiting buildings nearby the project site during construction work as well as of the building’s surroundings such as but not limited to public road, gate, lawn. He will study and execute the necessary scaffolding to support the building, in order to avoid any cracks, settlements, or crumbling. This scaffolding to support the building during the works are included in the prices given. Debris will be cart away to certified debris places in the area. In no way, debris will be stored, buried or burned on site.
1.6 After the works, the contractor will do a thorough cleaning of the construction site, this means cleaning of all excess mortars, cement bags, excess blockwork, excess tile jointing – in short any construction remnant which hinders the proper use of the house upon site hand-over.
NHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
1.7 In general the contractor will put his professional experience and craftsmanship to work, in order to get a holistically well-constructed building, to the highest and most up-to-date standards of Sudan Construction & international Culture.
2 Organisation of Construction Site
This includes all necessary preparations to execute the works; at least from the beginning until the end of the works; according to the best knowledge and experience of the contractor: at least conform local standards.
The objectives of the Bill of Quantities are
(a) to provide sufficient information on the quantities of Works to be performed to enable bids to be prepared efficiently and accurately; and
(b) when a Contract has been entered into, to provide a priced Bill of Quantities for use in the periodic valuation of Works executed.
In order to attain these objectives, Works have been itemized in the Bill of Quantities in sufficient detail to distinguish between the different classes of Works, or between Works of the same nature carried out in differently or in other circumstances which may give rise to different considerations of cost.
4 The Bills of Quantities for the Works comprise the following:
Preamble to Bill of Quantities
List of principal Quantities
Bill Nr. 1 Mobilization
Bill Nr. 2 - 10 Civil, Electrical Installation & Sanitary Installation
Bill Nr. 11 Day Works
5 The Contractor’s unit rates in these bills are to cover supplying of materials, taking delivery, transporting, loading and off loading inspection, storage, stacking, landing, preparation, installation including provision of all labour, requirement false work, temporary support, surface preparation and testing of the works. The rates shall include all applicable taxes and duty. The cost of testing of the materials to be used in the works unless otherwise provided is to be included in the rates of the respective Bill items.
6 Measurement for payment shall be for the complete installation and having passed all necessary tests.
7 Work shall not be executed on a Day work basis unless ordered in writing by the Consultant on approval by the Employer. The rates entered in the Day works Bill of Quantities shall apply to any quantity of Day work instructed by the Consultant. Nominal quantities have been indicated against each item to permit the extended total to be carried forward to the Grand Summary.
8 “Rates and prices shall be inserted in the rate and total columns of the Bill of Quantities in USD
9 Bills of Quantities are to be read in conjunction with the Instructions to Bidders, the Conditions of Contract Data, the Specifications and the Drawings. The quantities stated against each item in the Bills of Quantities, with the exception of those items specifically marked ‘sum’, are the estimated quantities of the Work to be executed by the Contractor in fulfillment of his obligations under the Contract.
10 The Contractor is required to check the number of the pages and should any be found to be missing or in duplicate he must inform the Engineer at once and have the same rectified.
11 No liability whatever will be admitted or claim allowed in respect of errors in the Contractor’s tender due to mistakes in the Bills of Quantities which should have been rectified in the manner described above.
12 The contractor shall not alter or otherwise qualify the text of these Bills of Quantities. Any alteration or qualification made without authority will be ignored and the text of the Bills of Quantities as printed will be adhered to.
13 Each item in the Bills of Quantities is to be priced. If any items are left un-priced it will be assumed that the value of the work described there under is elsewhere allowed for. The prices and rates to be inserted in the Bills of Quantities are to be fully inclusive of all costs and expenses which may be required for the construction of the work described, together with general risks, liabilities and obligations set forth or implied in these documents.
14 In no case will any claim for expenses incurred by the Contractor in preparation of this Tender be allowed.
15 The Contractor is solely responsible for the accurate ordering of materials in accordance with the Specifications, Drawings and Engineer’s Instructions and no claim for any loss or expense will be entertained for orders for materials based on the Bills of Quantities.
16 The quantities given in the Bills of Quantities are estimated and no claim by the Contractor for the final quantities being larger or smaller than the quantities given in the Bills of Quantities will be permitted except alows in accordance with the particular of the Conditions of Contract.
17 The dimensions given in the Drawings are generally in millimeters unless otherwise indicated. Levels are given in meters.
18 The term ‘provide’ or ‘supply’ used for any item shall be deemed to include transport to site, handling, storage and fixing complete, and the Bidder’s rate shall include for this.
19 The following abbreviations have been used in the Bills of Quantities:-
ml metre linear
m2 square metre
PS provisional Sum
Set Complete set of work with accessories & components
lot Complete set of work with accessories & components
PS provisional Sum
USD United States Dollar
uPVC un-plasticized poly vinyl chloride
HDPE high density polyethylene
GMS galvanized mild steel
PPE personal protective equipment
ASTM American society for testing & material
GW well-graded gravel
GP poorly-graded gravel
GM silty gravel, gravel-sand-silt mixtures
GC Clayey gravels, gravel sand-clay mixtures
SW well graded sands
SP poorly graded sands
SM silty sand, sand -silt-mixtures
SC clayey sands, sand-clay mixtures
AASHO American Association of State Highway and Transportation Officials,
ACI American Concrete Institue
RHS rectangular hollow section
PVD Physical Vapor Deposition
HCB hollow concret block
CBR california bearing ratio
MC medium curing
SDB sub distribution board
PDB pump distrbution board
20 Unless otherwise provided there are no separate measurement items for Contractual requirements. The Contractor is deemed to have included his costs for the Contractual requirement
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
HAYA VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
GRAND SUMMARY Amount in USD
1 Bill Nr.1 - Mobilization USD 0.00
2 Bill Nr.2 -Model Veternary Building-
2.1 - Civil Work USD 0.00
2.2 - Electrical Installation Work USD 0.00
2.3 -Sanitaryl Installation Work USD 0.00
3 Bill Nr.3 - Solar PV USD 0.00
4 Bill Nr.4 Pump Control Swith Shed with platform-Civil Work USD 0.00
5 Bill Nr.5 Septic Tank & Soak Away Pit-Civil Work USD 0.00
6 Bill Nr.6 Cattle Waste Holding Tank-Civil Work USD 0.00
7 Bill Nr.7 Site Works-Civil USD 0.00
8 Bill Nr.8 Site Work-Electrical USD 0.00
9 Bill Nr.9 Site Work-Sanitary USD 0.00
10 Bill Nr.10 Signage USD 0.00
GRAND TOTAL USD 0.00
11 Bill Nr.11 - Day Works USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
HAYA VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill Nr. 1- Moblization
1 SIGN BOARD USD 0.00
2 SITE SUPERVISOR TRANSPORTATION USD 0.00
3 SAFTEY HARNESS & PROTECTION USD 0.00
4 SAFTEY & SECURITY OF WORKS USD 0.00
5 SHOP DRAWINGS USD 0.00
6 Existing Condition/Demolishing Work USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 Contractor to provide a Project Identification sign size (200 cm × 200 cm), Contractor to submit shop drawing for UNOPS Engineer Approval, also 2 safety signs (120 cm x 120 cm). Saftey signed to be submitted to approval of Engineers. LS 1.00 0.00
2 Site Supervisor Office & Transportation
2.1 Providing offfice for supervion team completed with office Desk LS 1.00 0.00
3 Saftey Harness and Protection
3.1 2 No (Minimum) Safety Harness with lanyards , 3 fire powder 6Kg fire extinguishers, and selection of gloves & safety glasses to be kept in UNOPS Office at all time, also contractor should in his price include the cost of providing all his staff and work force with suitable PPEs ( i.e. Hard Hat, Safety Boot, Dust Masks, Safety Vests and Safety Glasses) Ls 1.00 0.00
4 Safety & Security of Works
4.1 Allow for providing safety and security for the Works and material as per the requirement laid under the Contract, including security lighting, lockable or open material storage areas, engaging security guards and / or any other measures as necessary. Cost shall include Road Safety awareness, and public traffic flow management during construction. LS 1.00 0.00
4.2 Providing, erecting, maintaining, and removing temporary site hoarding/fence made of corrugated iron sheets (C.I.S.) securely fixed to eucalyptus posts, including all posts, bracing, fixing materials, excavation, installation, maintenance, dismantling, and disposal upon completion. The hoarding shall be approximately 2.4 m high and installed along the site perimeter adjacent to the public road and other accessible areas, as directed by the Engineer, to prevent unauthorized access and ensure site security. ml 93.00 0.00
5 Shop Drawings
5.1 Allow for prepare and submit to the Engineer's Representative a complete set of Shop Drawings, as required to the specified scale(s), giving all details, as required by the Engineer's Representative, for the work executed. Submission shall be in 3 sets as hard copies, colour printed on A1 size paper and 01 set of soft copies in AutoCAD compatible version in a compact disc. LS 1.00 0.00
6 Existing Condition/Demolishing
6.1 Demolishing
The work shall be performed by qualified personnel who have ample experience in demolishing and safety work in order to avoid risk in the existing structure and in human life. Any useful dismantled materials shall be kept in proper manner and submitted to the client after proper cleaning. The contractor shall take all the responsibility of worker discipline in order to avoid disturbance and security issues at the work place and the entire compound. The contractor shall protect the existing area with approved standard plastic or other protective cover. Contractor is advised to investigate the scope of dismantling work before filling in prices.
The rate shall include breaking, cutting, dismantling, loading, hauling and disposal of all demolished materials, debris and unsuitable materials to an approved disposal area designated by the Engineer/Employer, including all labor, tools, plant, equipment, lifting and hauling facilities, water, temporary works, protection of adjacent structures and services, dust suppression, cleaning of the site, and all other incidental works necessary to complete the demolition safely and entirely in accordance with the drawings, specifications and Engineer’s instructions.
The contractor shall take all necessary precautions to prevent damage to adjacent buildings, utilities, pavements and other retained structures. Salvageable materials, if any, shall be separated and handed over to the Employer as directed by the Engineer. The area shall be left safe, clean, level and ready for subsequent construction works. The contractor shall submit methodology and work plan for approval by the Engineer before commencing the Works. contractor is advised to go through the detail of the building structure during pre-bid site visit.
A Demolition and complete removal of the Existing Building “B” as identified in the Architectural Drawing Legend, having a single story building with built up dimension of 7800 x 8000mm + 3200 x 3600mm and an average height of 2.80 m, comprising three rooms & verenda. The work shall include, but not be limited to, all necessary preparation, protection, temporary support and safety measures; dismantling and demolition of approximately nine (9) reinforced concrete columns, grade beams, roof/tie beams and associated reinforced concrete footings extending to approximately 1.50 m below existing ground level; demolition and removal of all concrete prefab external envelope and internal partition walls; dismantling of the eucalyptus timber roof structure and removal of corrugated iron sheet (C.I.S.) roof covering; removal of all existing metal doors, windows, frames, fixtures and other associated building elements such as disconnecting electrical & sanitary system. Ls 1.00 0.00
B Demolition and complete removal of the existing wire mesh perimeter fence, comprising RHS steel structural framing with vertical supports spaced at approximately 4.00 m c/c and three (3) horizontal RHS support members between vertical posts. Each vertical support shall be dismantled and removed together with its approximately 400 × 400 × 500 mm reinforced/plain concrete foundation pad, including any embedded steelwork, fixing plates, bolts, ties and associated components. ml 86.00 0.00
6.2 Saw cutting and preparation of existing asphalt pavement at the interface with new entrance gate interlocking pavment, including straight-line cutting to full asphalt depth, removal of loose and deteriorated material, thorough cleaning by air compressor, application of concrete edge restrain, and proper bonding of new interlocking pavment to existing pavement to form a smooth, watertight, and durable joint, all complete as directed by the Engineer. Rate shall include all labor, materials, equipment, tack coat, cutting tools, compaction, protection of adjacent works, and all incidental works necessary to achieve a seamless transition between existing and new pavment surfaces. Ml 4.00 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
HAYA VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.1- Veternary Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 GLAZING USD 0.00
8 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 294.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 75.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 202.00 0.00
1.4 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 23.00 0.00
1.5 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 126.00 0.00
1.6 Ditto as above item 1.5 but around isolated footing. m3 188.00 0.00
1.7 Ditto as above item 1.5 but around masonry foundation wall. m3 12.00 0.00
1.8 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 391.00 0.00
1.9 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 177.00 0.00
1.10 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 217.00 0.00
1.11 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 104.00 0.00
2.1.2 Under masonry foundation wall m2 47.00 0.00
2.1.3 Under grade beam m2 22.00 0.00
2.1.4 Under slab on grade including ramp & outdoor treatment m2 177.00 0.00
2.1.5 Under masonry steps on grade m2 2.00 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 39.00 0.00
2.2.2 In foundation column. m3 4.00 0.00
2.2.3 In grade beams. m3 15.00 0.00
2.2.4 In 15 cm thick ground floor slab including ramps & outdoor tratment. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 177.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 55.00 0.00
2.3.2 To foundation column m2 45.00 0.00
2.3.3 To grade beams & ramps edge m2 155.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 8 mm deformed bar Kg 17.00 0.00
Dia 10 mm deformed bar Kg 53.00 0.00
Dia 12 mm deformed bar Kg 2,117.00 0.00
Dia 14 mm deformed bar Kg 819.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 244.00 0.00
Dia 14 mm deformed bar Kg 170.00 0.00
Dia 16 mm deformed bar Kg 818.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 327.00 0.00
Dia 14 mm deformed bar Kg 331.00 0.00
Dia 16 mm deformed bar Kg 1,020.00 0.00
2.4.4 For floor slab on grade, ramp slab & outdoor tratment slab
Dia 8 mm deformed bar Kg 648.00 0.00
Dia 10 mm deformed bar Kg 173.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 46.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 2.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 8.60 0.00
1.1.2 In top tie beams m3 10.60 0.00
1.1.3 In water tanker slab with beams m3 1.20 0.00
1.1.4 In lintel beams including roof vent windows m3 0.30 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 91.00 0.00
1.2.2 To top tie beams m2 108.00 0.00
1.2.3 To water tank slab with tie beam m2 9.00 0.00
1.2.4 To lintel beams including for roof vent windows m2 3.00 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 182.00 0.00
Dia 16 mm deformed bar Kg 812.00 0.00
1.3.2 For top tie beam
Dia 8 mm deformed bar Kg 270.00 0.00
Dia 14 mm deformed bar Kg 294.00 0.00
Dia 16 mm deformed bar Kg 1,101.00 0.00
1.3.3 For water tanker slab & beam
Dia 8 mm deformed bar Kg 8.00 0.00
Dia 10 mm deformed bar Kg 100.00 0.00
Dia 16 mm deformed bar Kg 28.00 0.00
1.3.4 For water tanker slab & beam
Dia 6 mm deformed bar Kg 8.00 0.00
Dia 12 mm deformed bar Kg 31.00 0.00
Total carried to summary USD 0.00
Walls shall be constructed from class 'B' hollow concrete block (H.C.B.). The blocks shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the blocks shall be in such a way that good key for plasterer is obtained on both side.
2.1 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. m2 349.00 0.00
2.2 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B), the hollow part shall be fully grouted with cement sand mortar and jointed in cement sand mortar mix (1:3) one side left for appropriate finishing and the other side left for to fix sika joint or fiber board.Price shall include cement sand mortar fill inside hollow part of the wall. For X-ray room back wall m2 62.00 0.00
2.3 Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) with vertical & horizontal stiffeners bedded and jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. The stiffening methods and application shall be as per the detail structural dwg. Price shall include stiffening concrete and reinforcement.Price shall also include the recessed decorative wall part showing on the right & left side of the building.-for parapet wall m2 48.00 0.00
2.4 Supply and lay 10 cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. m2 6.00 0.00
2.5 Supply, delivery, preparation, and installation of combined brick layers of ( 20 cm + 10 cm),total 30cm thick red burnet brick wall cladding for internal X-ray room walls surface shown on the Ar. Drawing.The construction must comply with radiation protection requirements and shall be proper sealed with sika or fiber board to prevent radiation leakage. The material physical property shall meet the minimal standard to suit the intended purpose. The installation work shall be as per the architectural detail plan and shall be install from bottom up. The contractor shall submit the material sample. Shop drawing showing fixing details. Installation method and mockup sample shall be constructed for the Architect approval.price shall include 10mm thick SIKA or fiber board joint filler (wall substrate) & bonding bar with HCB wall. m2 62.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 235.00 0.00
3.2 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet ridge hip at the roof slope direction changes. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of ridge cap: 80 cm. m.l. 9.00 0.00
3.3 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 50.00 0.00
3.4 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel vally gutter, supported by the side truss members the work shall include all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 450 mm ml 4.50 0.00
3.5 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet copping at the top roof ridge exposed HCB wall. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of copping: 410 mm. m.l. 24.00 0.00
3.6 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 44.00 0.00
3.7 Supply and fix diam 110mm PVC down pipe. Price shall include 900 elbow connection, PVC liner with all the necessary fixing accessories. ml 52.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors and windows all as per the drawing. All doors should have vertical metal grill 25x25x2mm c/c 15cm for burglar proofing and with 0.5mm thick steel louver at top welded to frames and covered with approved mosquito net. All windows should have RHS 10x10x2mm welded to frames and with steel mesh for burglar proofing. All roof vent should have steel mesh welded on the frame. Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint. (glazing measured separately).
TW-1 size 150 x 85 cm no 2.00 0.00
D-1 size 180 x 255 cm-doble leaf door no 1.00 0.00
D-2 size 90 x 255 cm-single leaf door no 6.00 0.00
D-3 size 85 x 255 cm-single leaf door no 2.00 0.00
4,2 Supply, deliver, install, test, and commission factory made steel-framed, lead-lined radiation shielding X-ray door with vision panel, complete with all accessories and certification. The material shall be Steel door frame and solid core door leaf, factory fabricated, Lead lining to door leaf and frame equivalent to 2.0 mm Pb minimum, Vision panel comprising lead glass with equivalent 2.0 mm Pb shielding, Complete set of heavy-duty ironmongery including hinges, lockset, handles, and door closer, Perimeter sealing with radiation-proof gaskets to prevent leakage, Proper installation including lead overlap at joints and shielding continuity and the work shall include Testing, commissioning, and submission of radiation protection compliance certificate. All are as per the detail door and window schedule and engineers approval.
D-1' size 180 x 255 cm-doble leaf door no 1.00 0.00
D-2' size 90 x 255 cm-single leaf door no 1.00 0.00
4,3 Supply, fabrication, and installation of rectangular roof ventilation unit, overall size 80 cm × 40 cm, consisting of fabricated from 38 mm LTZ-profile, 0.16 cm thick frame. Joints to be welded with 4 mm continuous fillet welds, ground smooth and free of sharp edges. Infill woven wire mesh aperture 1.4 mm × 1.4 mm, wire diameter 0.45 mm, securely fixed to frame by recessed groove or retaining clips. Entire vent unit to be cleaned, degreased, and painted with on coat of anti-rust followed by two coats of metal paint. The color shall be approved by the Engineer and the work shall complete as per drawing. no 8.00 0.00
4.4 Supply, fabricate and fix metal guard rail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 120 × 120 × 6 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 1000 mm above finished floor level; two horizontal balustrade rails CHS Ø20 × 2.5 mm welded to vertical RHS posts; top handrail CHS Ø50 × 2.5 mm welded continuously; infill: vertically spaced CHS Ø20 × 2.5 mm at c/c 100 mm between the two horizontal rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 21.00 0.00
4.5 Supply, fabricate and fix metal ramp handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 15.00 0.00
4.6 Supply, fabricate, deliver, install, and paint steel cattle fence (balustrade type) comprising CHS vertical posts, horizontal rails, and base plates, fixed to concrete floor, complete in all respects. The work shall be Steel fence consisting of Ø100 × 5 mm CHS vertical posts (900 mm height) fixed to concrete using 170 × 170 × 6 mm base plates, spaced at maximum 1000 mm centers, with 4 No. horizontal Ø80 × 2.5 mm CHS rails welded to posts, including all welding, anchoring bolts, alignment, and accessories, finished with anti-rust primer and final metal paint (minimum two coats each), complete as per drawings and Engineer’s approval. ml 14.00 0.00
4.7 Supply and fix elevated water tanker seat metal guard rail all according to size and shape specified on the drawing . Price shall include connection plates, bolt and one coat of primer & two coats of synthetic enamel paint. ml 8.00 0.00
4.8 Ditto as above item and supply, fabricate, deliver,instal and paint steel structure ladder as shown the At. detail drawing. ml 8.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect steel structures using RHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel Structure Column
Steel structure columns are vertical primary load-bearing members, transferring axial loads (and occasionally bending) from trusses to foundations. Since columns are in direct contact with water during cleaning, apply bituminous damp-proof paint at the column base up to a height of 300 mm (30 cm) to prevent corrosion and moisture penetration. price shall damproof paint and stiffening plates as shown in the drawing. for measurment net RHS post will be considered execluding stiffening plates.
A.1 Steel structure column RHS sections of 100 × 100 × 4mm for veranda post. kg 218.00 0.00
B. Steel Structure Column Beam
The beam shall be welded column to column just below the top plate level where truss and column connected. At the end of the beam where there is no steel column. it connected with the building it will be fixed with plate at the concrete column/tie beam
B.1 RHS 80 x 60 x 4mm beam for veranda kg 245.00 0.00
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards. Price shall include gusset plat, connection plate when truss members connect and bolts other than anchor/J-bolt bolts.
C.1 RHS 80 x 80 x 4mm upper & lower truss member for T1, T-1',T-2' & T2 Kg 1,701.00 0.00
C.2 RHS 60 x 60 x 3mm upper & lower truss member for T3, T4 & T5 Kg 434.00 0.00
C.3 RHS 60 x 60 x 4mm diagonal & vertical truss member for T1, T-1', T-2' & T2 Kg 685.00 0.00
C.4 RHS 50 x 50 x 4mm diagonal & vertical truss member for T3, T4 & T5 Kg 149.00 0.00
D. RHS Purlins 0.00
D.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 100 x 100 x 3mm L= 60mm angle iron. Price include angle iron. Kg 2,145.00 0.00
E. RHS Solar PV Support System 0.00
Supply, fabricate, deliver and install solar panel steel support structure complete with all necessary connection components. The work shall include provision of gusset plates, bolts, nuts, washers, and all fixing accessories required for proper assembly and stability of the structure.The rate shall include surface preparation and application of approved anti-corrosion primer and finishing paint. It shall also include proper sealing and waterproofing treatment where steel members penetrate the roof covering, ensuring no water leakage. All works shall be executed in accordance with approved shop drawings, specifications, and engineer’s instructions.
E.1 RHS 80 x 80 x 4mm steell structure frame member Kg 3,005.00 0.00
E.2 RHS 40 x 40 x 4mm purlin Kg 553.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate for verenda post-size 250 x 250 x 6mm with 4 dia 22 slotted holes. The plated is welded to the RHS post (fillet weld of 3mm throat thickness) and connected to the other plate fixed on concrete column. No 12.00 0.00
A.2 Base plate size 250 x 200 x 6mm with 4 dia 18 slotted holes for truss & ring beam. The plate is welded to the truss (fillet weld of 3mm throat thickness) and connected to ring beam. No 98.00 0.00
A.3 Top plate size 150 x 150 x 8mm for veranda post and RHS beam connection with bolt & nut. No 12.00 0.00
B Bolt with nut
B.1 Base plate/Anchor bolt dia. 16 Length 250mm for truss beam connection and to be weld to ring beam steel reinforcement No 196.00 0.00
B.2 Base plate/Anchor bolt dia. 20 Length 450mm for veranda post No 24.00 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of gypsum finish to internal HCB wall surfaces. m2 535.00 0.00
6.2 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of gypsum finish to internal exposed beam and column surfaces. m2 69.00 0.00
6.3 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive rendering finish to externall HCB wall surfaces. m2 205.00 0.00
6.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final rendering finish to external exposed beam and column surfaces. m2 112.00 0.00
6.5 Prepare the surface and apply final a 3 mm to 5 mm thick final skim coat using a 1:3 cement-to-fine-sand mortar mix. Fine sand must be sieved through a 1.18 mm mesh. The surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks to internal wall, beam & column surfaces. m2 604.00 0.00
6.6 Prepare the surface and apply final apply 15mm thick cement and sand rendering (1:3 mix) for external wall surface. Price includes surface preparation, hacking of concrete surfaces, wire mesh for joints, curing for 7 days. The rendering pattern shall be as per the Architect approval. m2 317.00 0.00
6.7 Prepare the surface, supply and construct 2 cm thick x 25 cm wide polished marble threshold for doors bedded on cement sand mortar 1:3. Price include 30mm thick cement sand mortar backing and white cement grouting. All are as per the detail Ar. Dwg. ml 10.00 0.00
6.8 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 59.00 0.00
6.9 Prepare the surface, supply and fix nominal thickness of 0.85 cm approved standard 60 x 60 cm non-slippery ceramic floor tiles bedded in an average 4.15 cm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 12.00 0.00
6.10 Prepare the surface and apply epoxy resin coating flooring as shown in the drawing- the epoxy flooring shall be suitable type for veternary clinic:- Epoxy floor, shall be applied on the concrete floor or 4.6 cm thick cement sand screed flooring using OPC cement and Rheomix 141 strengthening additive in order to achieve the required bedding strength for animal hoof. The application of the screed shall be leveled and finished with a fine texture screening while the concrete is fresh and it is preferable to hold the proper application of epoxy floor finish with out any additional leveling. screed to the base floor shall be done with proper slope as instructed by the engineer and shall be done as per the advice and follow up of the epoxy supplier in order to assure the bonding between the concrete slab and screed. The contractor should use bonding chemical agent primer that shall be approved by the Engineer. Price shall include screed, Rheomix 141 strengthening additive and epoxy floor finish. m² 38.00 0.00 4800 0 0 4800 #REF! #REF! #REF! #REF! #REF! #REF!
6.11 Prepare the surface and construct belt & brace flooring as shown the detail Ar. Detail drawing. The work shall be 1 x 2 cm slip resistance diamond grooved finish with non metalic dry shake hardner. All are as per the detail drawing, manufacturere instruction and Engineer approval. m² 93.00 0.00
6.12 10cm high 1cm thick chamfered ceramic skirting of matching color to floor tiles. ml 106.00 0.00
6.13 Supply and fix 30 x 60 x 0.85 cm ceramic wall cladding, of matching color to floor, stuck to wall with cement sand mortar 1:3 backing and grouting with white cement wash. Price shall include rod anchors to backing. Size, color and pattern according to architect's drawings. m2 106.00 0.00
6.14 Supply and fix granite stair tread bedded on cement mortar 1:3 price include mortar bed, nosing and chamfering. Color and pattern shall be approved by the Architect.
a) For entrance step-tread
- Tread size: (33 x 3 cm) ml 8.00 0.00
6.15 Ditto as above but riser.
a) For entrance step-rise
- riser size: (13.4 x 2 cm) ml 8.00 0.00
6.16 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick marble window sill. Price shall include cement sand mortar bed and cement grouting. ml 12.00 0.00
6.17 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick marble short wall copping. Price shall include cement sand mortar bed and cement grouting. ml 12.00 0.00
6.18 Supply and fix chamfered, bullnose and water dripped 25 x 3cm thick marble edge trim for veranda edge. Price shall include cement sand mortar bed and cement grouting. ml 21.00 0.00
6.19 Supply and fix approved quality 0.8cm thick chip wood ceiling as per the detail drawing and engineers approval. The batten fixing method with steel truss shall be L-shaped or U-shaped steel brackets welded/bolted to the steel truss members. Battens are then nailed or screwed to the brackets. Price shall include 4 x 5 cm suspensions wooden battens with c/c spacing of 600mm both ways, middle and corner list, nails and all the necessary fixing accessories. m2 105.00 0.00
6.20 10 cm thick Concrete pavement around the building bedded on 10 cm thick red ash or fine aggregate and 20cm thick compacted granular materials. The work shall be mixing, placing, compacting, curing, and finishing of concrete with trowel finish while fresh. Price shall include red ash bed, selected fill and trowel finishing work. m2 90.00 0.00
Total Carried to summary USD 0.00
7.1 Supply and fix 0.5cm thick clear glass. Price shall include all the necessary fixing accessories. m2 15.00 0.00
7.2 Supply and fix 0.5cm thick figured glass. Price shall include all the necessary fixing accessories. m2 6.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
8.1 Apply three coats of plastic emulsion paint to internally gypsum plastered wall surfaces. m2 604.00 0.00
8.3 Ditto as item 8.1, but to chip wood ceiling. m2 105.00 0.00
8.3 Apply final acrylic emulsion paint to external rendered wall surface, exposed R.C columns and beams. m2 317.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
HAYA VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.2- Veternary Building-Electrical Installation
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
9 ELECTRICAL WORKS
9.1 uPVC Pipes and Ducts
9.1.1 50mm diameter uPVC m 10.00 0.00
9.2 Earth Network (Grounding System)
9.2.1 Grounding pit 500x500x500mm with top cover inscribed "Grounding pit" as per the detail drawing No 1.00 0.00
9.2.2 Under ground termination network with bare copper cnductor of 1x70sq.mm ml 100.05 0.00
9.2.3 Insulated ground connecting copper cable of 1x70sq.mm ml 30.00 0.00
9.2.4 Earthing electrode diameter 20mm and length 3000mm
Note:If the earth resistence is more than 10 ohms
add additional electrode spaced at length of
the electrode (spaced at a minimum of 5m appart) No 5.00 0.00
9.3 DISTRIBUTION BOARDS
9.3.1 Factory assembled and tested surface-mounted main distribution Board, MDB in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting:
1pc main RCBO of 50A, 3ph , Icu=16KA, 30mA.
1pcs MCB of 32A, 3ph , Icu=10KA
2pcs MCB of 20A, 1ph , Icu=10KA
7pcs MCB of 16A, 1ph , Icu=10KA, coupled with RCD of 30mA. 0.00
8pcs MCB of 16A, 1ph , Icu=10KA
4pcs MCB of 10A, 1ph , Icu=10KA
2pcs MCB of 16A, 1ph (spare) Icu=10KA
1Pc of surge arrestor of 40KA
3 pcs current meters of 50/5A with 6A fuse
1 pc Volt meter of 500V with selector switch and 6A fuse
1 pc frequency meter
with 25% reserve space and busbar of 63A/3ph. No 1.00 0.00
9.4. Feeder Cables and PVC pipes
PVC Sheathed PVC Insulated power cable type NYY 0.6/1KV or equivalent to be drawn inside riser shaft or PVC conduit (measured elsewhere, tentative) and of:-
Cable sizes include: 0.00
9.4.1 5x10 mm2 From utility connection to MDB (Provesional Quantity) m 20.00 0.00
9.4.2 5x10 mm2 From Inverter to MDB m 5.00 0.00
9.5. Light & Switch Points 0.00
9.5.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 46.00 0.00
9.6. Light Fittings and Lamps 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved.
9.6.L1 LED Panel Light: 600x600mm, 22.5W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 6.00 0.00
9.6.L2 LED Panel Light: 300x1200mm, 27W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 8.00 0.00
9.6.L2E LED Panel Light: 300x1200mm, 27W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free, & ~1000 lumens (emergency), 4000K, 90 minute operation, No 3.00 0.00
9.6.L3 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 11.00 0.00
9.6.L4 LED Batten Light:L600mm, CRI > 80, ceiling-mounted, polycarbonate, IP44, flicker-free. No 2.00 0.00
9.6.L5 LED Slim Downlight: 10W, 1100 lumens, 4000K, CRI > 80, polycarbonate, IP44, 220VAC, driver included, No 8.00 0.00
9.6.L6 Mini LED Wall Pack for Toilet Mirror, 10W, 1000 lumens,4000K, CRI > 80, wall-mounted, polycarbonate, IP65 No 3.00 0.00
9.6.(E) Non-maintained LED emergency light (only activates during power failure). Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). Warranty: 3 years (components), 5 years (battery). No 4.00 0.00
9.6(ODL) Over door light bulk head to indicate occupancy of the xray room No 1.00 0.00
9.6. Socket Points 0.00
9.6. 10-16A/1P flush mounted/recessed socket outlets point fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 20.00 0.00
9.9.2 Dito but for Double Outlet No 10.00 0.00
9.7 Power outlet points.
9.7.1. 16A/1P power outlets point for exaust fan and booster pump fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 8.00 0.00
9.7.2 20A/1P power outlets point for split AC fed through PVC insulated conductors of 3x4mm² inside PVC conduits of 19mm inner diameter, including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type-approved. No 2.00 0.00
9.7.3. 32A/3P power outlets point for X-Ray Machine fed through PVC insulated conductors of 5x6 mm² inside PVC conduits of 32mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 1.00 0.00
9.7. Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard.
9.7. Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete.
9.7.1 Single Pole 1-Way Switch No 6.00 0.00
9.7.2 Double pole Switch No 6.00 0.00
9.7.3 Two Way Switch No 6.00 0.00
9.7.4 Two Way Switch Weather proof for outdoor installation No 2.00 0.00
9.7.4 Intermidiate Switch Weather proof for outdoor installation No 1.00 0.00
9.8. Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00
9.8.1 16A ,1ph ,220V 2p+e socket out let No 20.00 0.00
9.8.2 Dito but Double (Twin) Outlet No 10.00 0.00
9.9 Lightning Arrester System
(Eritech or Equivalent)
Shall include all metalic structures in the network with appropriate welding (ventpipes,ducts ,GIS roof & structures, solar PV panels, e.t.c)
9.9.1 Early Streamer Emmision(ESE) Protector SI 25 with mounting mast of H=3.0m and all necessary connecting acessories. No 1.00 0.00
9.9.2 25x3mm copper tape with all necessary roof connecting accessories m 90.00 0.00
9.9.3 25 x 3mm insulated copper tape with vertical supportings every 1m to the wall & all the necessary accessories coordinate the routing of down conductors with the building external skin and architectural features. ml 40.00 0.00
9.9.4 Lightening Event counter to be installed on the down conductor to count number of lightening strikes. No 2.00 0.00
9.9.5 Test point (junction box) with all necessary connection acessories to connect the down conduction with the earthing bare copper wire. at least 1.5m above floor finish. No 2.00 0.00
9.9.6 Prefabricated Crowsfeet 25x3mm tinned coper tape. In complienc with IEC-EN 62561-2, with L1=1000mm and L2= 3000mm No 2.00 0.00
9.9.7 50 x 50 x 50 cm test pit with top cover inscribed "Test pit" as per the detail drawing No 5.00 0.00
9.9.8 1 x 70 sq.mm bare copper wire. ml 10.00 0.00
9.9.9 Diameter 20mm & 3000mm long copper rod. No 2.00 0.00
9.10 DATA\ Telecome System
Tel/Data according to manufacturer’s and utility supplier’s requirements, supplied, installed, connected color coded including tags and tested, complete, all as specified and / or as shown on the drawings
Structured Cabling
Horizontal CAT6A Cabling
9.10.2 Tel/Data and Data/Data points fed through 2x(twisted pair category 6A UTP cable) inside FRLS PVC conduits of 20mm diameter and thickness not less than 1.5mm with conduits accessories (coupling, junction boxes) for tele/Data outlet socket. No 11.00 0.00
9.10.3 Cat 6A 24 port Patch Panel RJ 45 contact No 2.00 0.00
9.10.4 Cat 6A RJ 45 Patch Cord 0.5m, from switch to pantch panels No 48.00 0.00
9.10.5 Cat 6A RJ 45 Patch Cord 3m, from outlets to workstation computers. No 11.00 0.00
Equipment Racking
9.10.6 Wall Mount metallic rack of 15U pivoting cabinet swing 19" steel enclosure with transparent and lockable door, Built-in PDUs (8-10 Outlets, Grounded) and cooling fans. No 1.00 0.00
9.10.7 1U Horizontal Cable Management Bars, 5 Vertical Plastic Hoops with Cover No 3.00 0.00
Information Outlets: Data &Voice
Extra Over Data Socket Outlets with Detachable Frames & Corresponding Box
9.10.8 2 x RJ45 8 Contact CAT6a Socket Outlets No 11.00 0.00
Active components Type CISCO or approved equivalent.
9.10.10 48-port Gigabit Data +2x10G uplink Switch . No 1.00 0.00
9.10.15 Hybrid PBX with 24Analog, with 4 trunk, Extension including Operator Phone No 1.00 0.00
9.10.16 Cat 6A RJ 11 Patch Cord 1m No 24.00 0.00
9.11 FIRE ALARM SYSTEM
9.11.1 Convensional Fire alarm Control Panel, 2 zones Complete with power supply & battery backup. No 1.00 0.00
9.11.2 smoke detector; with Flash Scan and Detector Base, Complete No 10.00 0.00
9.11.4 Fire alarm sounder strobe (RED) No 2.00 0.00
9.11.5 Surface mounted manual break glass push button including back box No 2.00 0.00
9.11.6 Flush Mounted Fire Alarm Points fed in 2 x 1.5sq. mm Fire Alarm cable (SLC-detectors) inside FRLS PVC conduits of 16mm diameter and thickness not less than 1.5mm with conduits accessories (coupling, junction boxes) No 14.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
HAYA VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.3- Veternary Building-Sanitary Installation
CLINIC BLOCK SANITARY WORKS
1.1 SANITARY EQUIPMENET ( FIXTURES ) USD 0.00
1.2 Water Supply Pipes and Valves USD 0.00
1.3 Waste Pipes and Accessories USD 0.00
1.4 HVAC System USD 0.00
1.5 Fire Fighting System USD 0.00
Total Veternary Clinic Building-Sanitary Installation USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 SANITARY EQUIPMENET ( FIXTURES )
All fixtures which are specified below is subject to the owner's / consultant's approval, based on samples, catalogues and brochures presented by the contractor. Unit price shall include all the necessary fixing brackets or hooks and all assistance civil works such as chiseling of walls, floors, beams and etc.
1.1.1 HAND WASH BASIN (ORDINARY)
Supply and fix R.A.K. or Equivalent, hand wash basins made of white glazed vitreious china with REMER/JAQUAR or Equivalent chrome plated cold water tap, pedastal stand ,complete with stop & arrest valves on water inlet pipe. mixing battery plug, chrome plated chain holder, P-smell trap with connection pipe, fittings, all other necessary etc.complete in all respects. Flexible hose to be REMER or Equivalent and should be capable of resisting pressure of 4 bar. P-smell trap should be brass chrome plated with 50mm height of water seal and trap. № 1.00 0.00
a) Size :- length X width (1000mm x 435mm)
1.1.2 Ditto No 1.1.1 but for animal health clinic medical laboratory and surgical purpose each with two bowl. № 2.00 0.00
1.1.3 Ditto No 1.1.1 but for cleaner room № 1.00 0.00
WATER CLOSET (ORDINARY)
1.1.4 Supply and fix wash-down action toilet squatting pans made of white vitreous china, complete with high-level flush cistern, vertical flush pipe connecting the cistern to the squatting pan, and all necessary accessories. The price shall include stop and arrest valves before water inlet; cistern of vitreous china with a capacity of 7 to 9 liters and maximum filling time of 2 minutes, complete with heavy-duty float valve suitable for water pressure up to 4 bar; chrome-plated steel flush valve; heavy-duty flexible pipes rated for a working pressure of 4 bar; and vertical flush pipe of durable corrosion-resistant material (e.g., galvanized steel, stainless steel, or UPVC) connecting the cistern outlet to the pan inlet, complete with necessary bends, brackets, and wall fixings. Where specified, a hygienic flush/bidet connection shall be provided, comprising a flexible hose, handheld spray nozzle, wall bracket, and appropriate isolating valve. № 2.00 0.00
SANITARY WARES FOR PERSONS WITH DISABILITY (PWD)
1.1.5 Supply and install complete set of sanitary wares for physically challenged toilet room fixtures and accessories including: *Vitreous china wc seat with brass or stainless steel hingedheavy duty plastic cover*Vitreous china hand wash basin with lever action faucet with mixer, brass or chrome smell traps and accessories * 6 liters capacity vitreous china cistern with long lever action flushing arm * 5 pieces of stainless steel grab rails (600x35mm) with slip resistant grip and concealed fixings* Blue Folding rails 850mm,760x305mm flush bends,cloth hooks * Stainless steel lever action hinged drop down rail * Color contrasted padded backrest * Automatic hand dryer * Soap Dispenser * Paper Towel Dispenser * Toilet Tissue Dispenser * Alarm Rest Button * Stainless steel Mirror 1000*400mm & all the necessary material to make the toilet functional. The sanitary ware set shall satisfy BS 8300-2 and BS EN 12182. № 1.00 0.00
1.1.6 WET ROOM ACCESSORIES
1.1.6.1 Supply and fix soap holder in white vitreous china of size 150 x 150 mm. Complete with the necessary fixing and other accessories. № 3.00 0.00
1.1.6.2 Supply and fix toilet paper holder from chrome plated brass wall flanged roll with chrome plated fastening screws and other accessories. № 2.00 0.00
1.1.6.3 Supply and fix crystal glass mirrors for toilets hand wash basins for changing rooms and private rooms with copper back protection, including chrome plated brass mirror clips with chrome plated screws and all the necessaary accessories. a) size 500 X 400 mm № 3.00 0.00
1.1.6.4 Supply, fix, test and commission floor drains made of polished steel, complete with P-smell trap /minimum seal depth 75mm/ and all other necessary fittings and accessories. № 4.00 0.00
Total carried to summary USD 0.00
1.2 Water Supply Pipes and Valves
Domestic water pipes shall be in PPR- PN 4 & be fixed to walls, beams or etc… with metal/ compatible straps. Unit price shall include all assistance civil works and necessary fittings such T, bends, Y, reducers Unions and other necessary valves shall be fixed properly as per the manufacturer's instruction and according to where shown on the drawing. Hot water supply shall be properly insulated and external PPR pipe has to be coated All water pipes shall be tested two times the working pressure or 100 meters head, which ever is greater at the expense of the contractor.
1.2.1 Supply and install PPR PN-4 pipes to internal domestic water distribution system pipes as where shown on the drawing. And external pipes shall be coated Complete with all the necessary fittings and accessories. The pipe shall be coated when applied on exposed surfaces
1.2.2 Supply and fix chrome service valves of approved standard before hand wash basins, water closets and other fixtures. Complete with unions, elastic water proofing, hand wheels of normal quality and with all other necessary accessories.
1.2.3 Ditto to item number 1.2.2 approved quality bronze gate valves on internal branch water pipes and pipe inlet to building of the following size and as where shown on the drawing
1.2.4 Supply, Installation, Testing, and Commissioning of Wall/Window Mounted Exhaust Fan: Fan Unit: The exhaust fan shall be a wall or window mounted type, specifically designed for bathroom/ toilet ventilation. Performance: Airflow Capacity: Minimum free air delivery of 200 cubic meters per hour (m³/hr) at 25 Pa static pressure. Sound Level: The maximum sound power level (Lw) shall not exceed 35 dB(A) when measured in accordance with relevant standards. Components & Accessories: The unit shall be complete with all necessary accessories for effective operation, including but not limited to: Multi-speed controller. Integral back-draft shutter. External rain guard/weather louvre. Grille or front cover. All required fixings, gaskets, and seals. Scope of Work: The unit rate shall be inclusive of, but not limited to, the following activities: Supply of the exhaust fan and all specified accessories. Necessary civil works to create or make good the opening, including sealing and making the installation weatherproof. Electrical wiring from the nearest power source, including a dedicated isolation switch, as per electrical codes. Final installation, testing, and commissioning of the system to ensure optimal performance. № 2.00 0.00
Total carried to summary USD 0.00
1.3 Waste & vent Pipes and Accessories
All domestic waste water pipe lines shall be uPVC (PN10) pipes and shall be provided with a minimum slope of 2% towards the outlet. All uPVC pipes and necessary fittings shall be standard quality and be free from damage during storage, construction and etc. Unit price shall include all the necessary assistance civil works, such as excavation cartaway, fixing or hanging to walls, beams or slabs.etc., necessary fittings such as bends, Y, T, etc.
1.3.1 Supply and lay internal uPVC waste according to where shown on the drawings. Complete with all the necessary fittings.
Dia. 50 mm ml 4.00 0.00
1.3.2 Ditto No 1.3.1 for vent pipes with appropriate end cap
1.3.3 FCO(FLOOR CLEAN OUT)
Supply and fix approved quality screw type under slab Clean Out on waste water as where shown on the drawing. Price shall include all the necessary
1.3.4 Animal waste open dith with galvanized steel grate for cattles out door treatment area ml 4.00 0.00
DITCH-: SIZE[mmXmm] = 300 X 300
1.3.5 Dito 1.3.4 but for animal health clinic cattles recovery room treatment area ml 4.00 0.00
DITCH-: SIZE[mmXmm] = 300 X 300
1.3.6 Dito 1.3.4 but for animal health clinic treatment room & X ray rooms.
DITCH-: SIZE[mmXmm] = 300 X 300 ml 8.00 0.00
Total carried to summary USD 0.00
1.40 HVAC System
Supply, installation, testing, and commissioning of HVAC and mechanical ventilation systems for four (4) distinct room types considering high ambient operation temperature of 52 ºC.The items shall be Anti-corrosion treatment for coastal sites, refrigerant pre-charged for up to 15m piping length, Service valves with Schrader ports. The scope of the work include power cabling work from power point to HVAC equipment.
1.4.1 Supply, install, test and commission a complete high ambient split-type air conditioning unit of 1.5 TR (5.3 kW cooling capacity, equivalent to 18,000 BTU/h). The unit shall be inverter type, utilizing R32 or R410A refrigerant (R22 is strictly prohibited), and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 1.3 kW. The system is designed for cooling only and shall be factory-rated for continuous operation in high ambient temperatures up to 52°C. The system shall consist of one (1) wall-mounted indoor evaporator unit and one (1) outdoor condensing unit, complete with all interconnecting refrigerant piping, control wiring, condensate drain line, remote control handset, and all necessary accessories for a complete and functional installation. Indoor Unit (Evaporator): The indoor unit shall be constructed of UV-stabilized ABS plastic with a white finish. It shall include automatic horizontal and vertical swing louvers, a washable antimicrobial pre-filter, and a cross-flow fan designed for silent operation.
Outdoor Unit (Condenser): The outdoor unit shall be an inverter-driven condensing unit with digital inverter (variable speed) compressor, specifically rated for high ambient operation. The unit shall include corrosion-resistant condenser coil and fan motor. Refrigerant Piping: Interconnecting refrigerant piping shall be provided for a distance of not less than 15 meters (49 feet) between the indoor and outdoor units. The piping shall consist of seamless copper tubing, with liquid line of 6.35 mm (1/4 inch) OD and suction line of 12.7 mm (1/2 inch) OD. The suction line shall be insulated with 13 mm (0.5 inch) thick closed-cell elastomeric foam. Control and Operation: The system shall include a wireless infrared remote control handset enabling full functionality. Features shall include LED display with temperature readout, sleep mode, turbo cooling mode, on/off timer (1-24 hours), auto restart after power failure, and self-diagnostic fault code display. Electrical Characteristics: The unit shall have rated load amps (RLA) of approximately 6.0 A, minimum circuit ampacity (MCA) of 8.0 A, and maximum overcurrent protection (MOP) of 15 A. All electrical components shall be rated for 230V / 50Hz supply. Condensate Drain: The unit shall include a condensate drain line of 25 mm (1 inch) nominal diameter PVC pipe, properly trapped and sloped at minimum 1:100 gradient to designated drainage point. Compliance: The equipment shall satisfy conformity with European health and safety standards (IEC 60335-2-40) or equivalent international certification acceptable in Sudan. The Contractor shall submit manufacturer cut sheets and conformity certificates for engineer's approval prior to procurement. Acceptable Brands: Gree, Midea, LG, Carrier, Daikin, or approved equivalent. № 1.00 0.00
1.4.2 Supply, install, test and commission a complete wall-mounted, high ambient exhaust fan for the X-Ray room, designed to provide mechanical extraction of air while maintaining negative pressure and preventing radiation leakage. The fan shall be mounted directly on the exterior wall face over a specially constructed shielded labyrinth penetration through the brick wall. No external ductwork shall be required. The fan shall be centrifugal or axial type,The fan shall deliver a minimum airflow of 150 m³/h (approximately 90 CFM) at static pressure of 100 Pa (10 mmH₂O or 0.4 inches w.g.) rated for continuous operation in high ambient temperatures, and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 0.08 kW (80 Watts) . The system is designed for exhaust-only ventilation (no supply fan) and shall be installed in conjunction with a passive labyrinth intake for fresh air. The system shall consist of one (1) wall-mounted exhaust fan (maximum power: 0.08 kW), one (1) shielded labyrinth penetration constructed through the brick wall, one (1) interior exhaust grille (high-level mounted), one (1) exterior weatherproof louver, one (1) backdraft damper, and all necessary accessories for a complete and functional installation. No ductwork (rigid or flexible) is required between the fan and the room. The Contractor shall construct a shielded labyrinth penetration of "S" or "Z" configuration (offset path) through the 450 mm thick wall. No straight line of sight shall exist from the interior of the X-Ray room to the exterior fan housing or to the outside environment. № 1.00 0.00
1.4.3 Ditto No 1.4.1 but for laboratory room and with cooling capacity of 2.0 TR (7.0 kW cooling capacity, equivalent to 24,000 BTU/h) and maximum power input of 1.80 kW (1,800 Watts) . № 1.00 0.00
1.4.4 Supply, install, test and commission a wall-mounted fresh air supply fan for the Laboratory Room, designed to provide forced filtered(with MERV 8 filter (replaceable type) to filter incoming outdoor air) outdoor air to meet the ventilation requirement. The fan shall be mounted directly on an exterior wall or window, requiring no ductwork. The fan shall be rated for continuous operation in high ambient temperatures up to 52°C, and shall operate on a single-phase 230V / 50Hz power supply with maximum power input of 0.1 kW (100 Watts) . Performance Characteristics: The fan shall deliver a minimum airflow of 200 m³/h (approximately 120 CFM) at static pressure of 50 Pa (5 mmH₂O or 0.2 inches w.g.) – lower static pressure is acceptable because no ductwork is attached. Construction: The fan shall be of wall-mounted type, suitable for through-wall or through-window installation. The fan casing shall be constructed of UV-stabilized ABS or galvanized steel with corrosion-resistant coating. The motor shall be sealed type, IP44 minimum (or IP54 for exterior exposure). The fan shall include: Integral backdraft damper (gravity-operated) to prevent reverse airflow when fan is off, Integral insect screen on exterior side,Exterior weatherproof louver (may be integral or separate),Interior grille (may be integral or separate) with manual damper for airflow adjustment, Mounting: The fan shall be mounted on a wall or window frame on one side of the room (e.g., the 4.8 m wall). A circular or rectangular hole shall be cut through the wall or window frame to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. The fan shall be installed level and plumb. № 1.00 0.00
1.4.5 Ditto No 1.4.4 but for exhaust air system designed to maintain negative pressure and remove airborne contaminants from laboratory room and shall deliver a minimum airflow of 500 m³/h (approximately 300 CFM) at static pressure of 50 Pa (5 mmH₂O or 0.2 inches w.g.) – lower static pressure is acceptable because no ductwork is attached. The fan shall consume maximum 0.1 kW (100 W) . Low-Level Mounting: For effective removal of heavier-than-air contaminants (e.g., chemical vapors, dust), the exhaust fan should be mounted low on the wall, approximately 200 mm to 500 mm above finished floor level. The Contractor shall confirm the mounting height with the Engineer prior to installation. Mounting: The fan shall be mounted on the wall opposite the supply fan (e.g., on the opposite 4.8 m wall). A circular or rectangular hole shall be cut through the wall to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. The fan shall be installed level and plumb. № 1.00 0.00
1.4.6 Ditto No 1.4.4 but for tretment room and shall deliver a minimum airflow of 900 m³/h (approximately 530 CFM) at static pressure of 50 Pa (5 mmH₂O), while consuming maximum 0.37 kW (370 W) . № 1.00 0.00
1.4.7 Ditto No 1.4.5 but for tretment room and shall deliver a minimum airflow of 150 m³/h (approximately 90 CFM) at static pressure of 50 Pa (5 mmH₂O), while consuming maximum 0.08 kW (80 W . The fan shall be mounted on the wall opposite the supply fan to achieve cross-ventilation. The fan may be mounted at mid-height (1.5 m AFF) or high level. A circular or rectangular hole shall be cut through the wall to accommodate the fan body. The annular space shall be sealed with expanding foam or silicone sealant. № 1.00 0.00
1.4.8 Ditto No 1.4.5 but for a complete exhaust-only ventilation system for the Animal Clinic Isolation Room, designed to deliver a minimum airflow of 1,000 m³/h (approximately 590 CFM) at static pressure of 150 Pa (15 mmH₂O), while consuming maximum 0.2 kW (200 W) maintain negative pressure for containment of airborne pathogens.The fan shall be mounted directly on an exterior wall, requiring no ductwork (or minimal ductwork for distribution). The fan shall be rated for continuous 24/7 operation, and shall operate on a single-phase 230V / 50Hz power supply. № 1.00 0.00
1.4.9 Ditto No 1.4.1 but for electric/battery room and with cooling capacity of 0.85 TR (2.5 kW cooling capacity, equivalent to 8530.36 BTU/h) and maximum power input of 0.60 kW (600 Watts) . № 1.00 0.00
1.4.10 Ditto No 1.4.5 but for a complete exhaust-only ventilation system for the toilet cubicles, designed to deliver a maximum airflow of 300 m³/h (approximately 176.57 CFM) at static pressure of 60 Pa (0.45 mmH₂O), while consuming maximum 0.06 kW (60 W) maintain negative pressure for containment of airborne pathogens.The fan shall be mounted directly on an exterior wall, requiring no ductwork (or minimal ductwork for distribution). The fan shall be rated for continuous 24/7 operation, and shall operate on a single-phase 230V / 50Hz power supply. № 2.00 0.00
1.4.11 Ditto No 1.4.10 but for janitory room. № 1.00 0.00
Total carried to summary USD 0.00
1.50 FIR FIGHTING SYSTEM
4.10 Supply and fix 5kg of ABC type fire extinguisher with metal protection cover as per shown location on the drawing. № 6.00 0.00
4.20 Ditto ( 4.1) but CO2 type for solar electrical control room № 1.00 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
HAYA VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.3 Solar PV Installation
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
Supply, install, test, and commission a roof-mounted solar photovoltaic (PV) system with a total installed capacity of 20.10kWp, complete with battery storage and a three-phase inverter, designed for reliable off-grid operation. The system shall be engineered for a minimum service life of 20 years, and shall include all required components, accessories, protections, and ancillary works necessary to deliver a fully functional and complete installation, consisting of the following:
1 PV Modules Type Longi solar or approved Equivalent
Monocrystalline bifacial module, 670 Wp, efficiency ≈24.8%, Voc ≈54.6 V, Vmpp ≈45.27 V, IEC 61215/61730 certified. 2 rows × 16 modules roof-mounted; Tier-1 quality and high reliability. Type Longi solar or approved Equivalent. No 30.00 0.00
3 Hybrid Inverter Type Huawei or approved equivalent
3-phase hybrid inverter, 25kW output, 2 MPPT (200–1000 V DC), efficiency ≥ 98.4 %. Integrated battery interface & smart monitoring. No 1.00 0.00
4 Battery System, Type Huawei or approved equivalent
Lithium Iron Phosphate (LFP) stack 15 kWh nominal (14.25kWh usable), 600 V DC nominal range (600–980 V) for 3Ph system. Safe chemistry >4000 cycles. stacks 2.00 0.00
5 Battery Control Modules (PCM)
Power Control Module per stack, manages communication and charge/discharge interface to the hybrid inverter. pcs 2.00 0.00
6 DC protection panel
IP65, 1000V DC protection panel (PV Rated) with busbar ≥ array Isc , 63A, earthing terminal, and all associated accessories consisting of:
2pc DC-rated MCB of 25A
2pc DC-rated String isolator of 32A
1pc, PV rated DC SPD, Type II, In ≥ 20KA pcs 1.00 0.00
All components shall be rated for a minimum of 1000 VDC and suitable for photovoltaic applications. pcs 1.00 0.00
7 DC & AC Cabling
Cu XLPE cables rated 1 kV DC/AC; Includes MC4 connectors, lugs, glands, and labels. ≤ 1.5 % V-drop. 0.00
7.1 1x 4mm2 1kv/DC cables, PV string connection ml 55.00
7.2 2x 6mm2 1kv/DC cables, PV string, and from DC protection Panel to Hybrid inverter. ml 15.00 0.00
7.3 2x 10mm2 1kv/DC cables from Hybrid inverter to Battery stacks. ml 10.00 0.00
7.4 5x 10mm2 0.6/1kv AC cables from Hybrid inverter(HIN) to MDB ml 10.00 0.00
8 Monitoring & Communication
Smart Dongle / Gateway (Wi-Fi or Ethernet). Real-time data, alarms, remote monitoring and system analytics. Type Huawei FusionSolar or approved equivalent. set 1.00 0.00
9 Earthing & Lightning Protection
The Solar PV strings shall be bonded to the Early Streamer Emission (ESE) lightning protection roof network using 25 × 3 mm copper tape to ensure effective lightning protection. The PV array structure shall also be bonded to the main earthing network through 70 mm² copper earthing cables, bonding bars, and lightning down conductors. The overall earthing system shall achieve an earth resistance not exceeding 5 Ω. LS 1.00 0.00
10 Installation, Testing & Commissioning
Complete installation of PV array, battery, inverter, wiring, earthing. Includes polarity, insulation, I-V curve, and BMS integration tests, training & handover. LS 1.00 0.00
11 Contingency / Miscellaneous
Spare connectors, cable glands, fasteners, transport, minor site materials. Covers unforeseen adjustments during installation. LS 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
HAYA VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.4-Water Reservior Plat form & Pump Control Switch Room-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A 0.00
B. SUPER-STRUCTURE
1 BLOCK WORK USD 0.00
2 ROOFING USD 0.00
3 METAL WORK USD 0.00
4 STEEL STRUCTURE USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No additional allowance for working space to be considered for measurement. The site clearing area shall be the net built-up area including aprons, open ditch, entrance step and ramp. m2 10.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for the ground floor from the Average Natural Ground Floor Level (A.N.G.F.L.) to a depth not exceeding 150 cm. The volume of excavation shall be measured only over the net built-up area of the building footprint, excluding aprons, open ditches, and ramps. Working allowance: An additional 0.50 m width on each side of the excavation shall be included to allow for proper working space. Reference level (A.N.G.F.L.): The A.N.G.F.L. is defined as the average of the topographic ground levels taken at the building footprint prior to any excavation works, reduced by 20 cm to account for above work item site clearing. m3 3.50 0.00
1.3 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level. Note: measurement shall include 150 cm working space in each side for trench excavation. m3 3.10 0.00
1.4 Back fill under hard core and around the building with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 3.00 0.00
1.5 Back fill around masonry wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 2.00 0.00
1.6 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material. Disposal shall be measured as the net volume arising from the void created by the excavation, less excavated material backfill, filled and wheel spread within site or left stockpiled. m3 8.60 0.00
1.7 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone.only under concrete channel. m2 1.50 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately.
2.1 5 cm thick lean concrete in grade/class C-5 concrete, minimum cement content of 150 kg/m3 :
A. Under ground floor slab m2 6.00 0.00
B. Under masonry foundation wall m2 5.40 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
A. In 20 cm thick slab m2 6.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
To slab edge m2 2.20 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
A. For slab on grade
Dia 10 mm deformed bar Kg 74.04 0.00
Total carried to summary USD 0.00
3.1 50 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 4.28 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
Walls shall be constructed from class 'B' hollow concrete block (H.C.B.). The blocks shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the blocks shall be in such a way that good key for plasterer is obtained on both side.
1.1 Supply and lay 20cm thick approved type Hollow Concrete Block wall (Class-B) jointed in cement sand mortar mix (1:3) both side left for pointing.Price shall include recessed pointing. m2 9.12 0.00
Total carried to summary USD 0.00
1.1 Supply and fix approved standard pre-painted 0.35mm thick corrugated iron sheet (C.I.S.) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). m2 4.62 0.00
Total carried to summary USD 0.00
3.1 Double-leaf metal door constructed from 40×40×3 mm RHS steel for vertical and horizontal framing, fully welded and braced with similar RHS sections as shown in the Architectural drawings. Door to be infilled with galvanized steel wire mesh 2.5 mm dia. at 25 mm c/c, welded to frame. Include all necessary welding, surface preparation, one coat of primer, and two coats of synthetic enamel paint to all steel surfaces. All work to conform to detailed drawings and relevant standards.
A. Door D1 size 170 x 150 cm. no 1.00 0.00
3.2 Wire mesh covering for pump control switch side walls made of galvanized steel wire mesh 2.5 mm diameter, spaced at 25 mm c/c, fixed securely to RHS structural frame using appropriate clamps or welding as shown on the drawings. The work includes cutting, fitting, welding (where required), surface preparation, one coat of metal primer, and two coats of synthetic enamel paint on all steel members. All materials and workmanship shall comply with the relevant standards and detailed drawings. m2 2.00 0.00
Total carried to summary USD 0.00
4 STEEL STRUCTURE
4.1 Supply, fabricate, assemble, and erect steel structures using RHS and CHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel Structure Column
Steel structure columns are vertical primary load-bearing members, transferring axial loads (and occasionally bending) from trusses to foundations. Since columns are in direct contact with water during cleaning, apply bituminous damp-proof paint at the column base up to a height of 300 mm (30 cm) to prevent corrosion and moisture penetration.
A.1 steel structure column using two RHS sections, 60 × 60 × 3 mm. not welded part single unit. ml 6.90 0.00
B. Steel Structure Column Beam
The beam shall be welded column to column just below the top plate level where truss and column connected. At the end of the beam where there is no steel column. it connected with the existing building it will be fixed with plate at the concrete column/tie beam
B.1 RHS 60 x 60 x 3mm beam ml 6.00 0.00
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards.
C.1 RHS 80 x 60 x 3mm rafter ml 4.00 0.00
D. RHS Purlins 0.00
D.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 100 x 40 x 3mm L= 60mm angle iron. Price include angle iron. ml 5.70 0.00
4.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate size 150 x 150 x 8mm with 4 dia.18 slotted holes for dia. 16 J-bolt No 8.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
HAYA VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.5-Septic Tank & Soak Away Pit-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. Price shall include all working space allowances deemed necessary. m2 25.00 0.00
1.2 Bulk excavation in ordinary soil to a depth not exceeding 150 cm starting from the natural ground level. Note: measurement shall include 25 cm working space for bulk excavation. m3 69.00 0.00
1.3 Ditto but from 150 cm to 300 cm m3 41.00 0.00
1.4 Back fill around retaining wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 27.00 0.00
1.5 Spread coars gravel at the bottom of soak away m3 1.41 0.00
1.6 Ditto as above but spread fine gravel fill between coarse gravel and 0.4 cm average sand fill. m3 0.35 0.00
1.7 Ditto as above but spread 0.4cm average sand fill between fine gravel & 0.2cm diameter fine sand. m3 0.35 0.00
1.8 Ditto as above but spread top layer soak away 0.2cm average fine sand fill. m3 0.55 0.00
1.9 Cart away excavated material from the site as approved by the Engineer. Soil shall be damped more than 1km. m3 115.00 0.00
1.10 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
A) The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube moulds necessary for the purpose and for submitting reports of the tests to the Engineer.
B) Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/ class C-5 concrete, minimum cement content of 150 kg/m3 :
2.1.1 Under septic tank bottom slab m2 13.00 0.00
2.1.2 Unde soak away pit m2 7.60 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In 20 cm thick septic tank bottom slab m2 13.00 0.00
2.2.2 In 20 cm thick septic tank top slab including ring beam m2 10.00 0.00
2.2.3 In 15 cm thick soak away top slab m2 5.00 0.00
2.3 Formwork shall be timbered or steel or a combination of two, sufficient to contain the wet concrete without leakage. Enough to support temporary loading and pressure from placing Compaction or vibration without displacement or appreciable deflection.
2.3.1 To septic tank bottom slab m2 3.20 0.00
2.3.2 To septic tank top slab including ring beam m2 7.00 0.00
2.3.4 To k top slab including ring beam m2 3.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 Bottom Slab
A. Diam 12mm Deformed bar. kg 214.00 0.00
A. Diam 12mm Deformed bar. kg 147.00 0.00
2.4.3 Tie submerged beam
A. Diam 10mm Deformed bar. kg 77.00 0.00
B. Diam 8mm Deformed bar for distribution bar kg 45.00 0.00
2.4.4 Soak away top slab
A. Diam 12mm Deformed bar. kg 75.00 0.00
B. Diam 8mm Deformed bar for distribution bar kg 31.00 0.00
2.10 Allow lump sum amount 60 x 60 cm concrete manhole cover Ls 2.00 0.00
2.11 Supply & fix wooden or equivalent 6,, thick wooden baffle as shown the detail drawing and Engineer’s approval Ls 1.00 0.00
Total carried to summary USD 0.00
3.1 Construct average 60 cm at bottom up to 120 cm & 50 cm thick width thick Basaltic or equivalent stone masonry septic tank retaining foundation wall bedded in cement sand mortar (1:4) below NGL. For septic wall. m3 15.00 0.00
3.2 Ditto as above but 50 cm thick masonry wall for soak away pit m3 9.00 0.00
3.3 Septic tank chamber partition:-Supply and lay 20 cm thick approved type Hollow Concrete Block wall (Class-B) with stiffeners bedded and jointed in cement sand mortar mix (1:3) both side left for appropriate finishing. Price shall include plastering m2 2.00 0.00
3.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to internal & external masonry wall surfaces. m2 52.00 0.00
3.5 Ditto as above item but for HCB chamber partition wall. m2 4.00 0.00
3.6 Allow lumps amount of sanitary uPVC work for septic tank inlet, chamber partition and out let pipes to soak away pit. ls 1.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
HAYA VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.6-Cattle Waste Holding Tank
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
TOTAL CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including 25 cm thick working allowance in each side. m2 21.90 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to an average depth of 150 cm. Note: measurement shall include the net area of the site clearing work. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. m3 32.85 0.00
1.3 Ditto as above item but to a depth above 150 cm but not exceeding 300 cm from reduced ground level. m3 18.61 0.00
1.4 Selected borrow fill around retaining wall with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 24.24 0.00
1.5 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 55.85 0.00
1.6 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described. All works shall be as per the structural general note.
2.1 5 cm thick lean concrete in grade/class C-5, minimum cement content of 150 kg/m3 :
2.1.1 Under bottom holding tank m2 17.00 0.00
2.2 Reinforced concrete grade/class C-25 (With a 28 day 150mm cube crushing strength of 25Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In 30 cm thick bottom slab m2 17.00 0.00
2.2.2 In 20 cm thick retaining/shear wall. m2 30.80 0.00
2.2.3 In 20 cm thick suspended top slab m2 11.78 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To bottom slab m2 5.58 0.00
2.3.2 To retaining/shear wall. m2 61.60 0.00
2.3.3 To suspended top slab m2 11.94 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For bottom slab
Dia 12 mm deformed bar Kg 444.00 0.00
2.4.2 For retaining/shear wall
Dia 8 mm deformed bar Kg 89.00 0.00
Dia 12 mm deformed bar Kg 1,025.00 0.00
2.4.3 For floor slab on grade
Dia 8 mm deformed bar Kg 12.00 0.00
Dia 12 mm deformed bar Kg 271.00 0.00
2.5 Internal surfaces of concrete cattle waste holing tank to be thoroughly cleaned and prepared by removing all dirt, laitance, grease, oil, algae, and loose material; all honeycombed, defective, or uneven surfaces to be repaired and made good with approved cement–sand mortar to provide a sound and smooth substrate. Supply and apply a two-component elastomeric cementitious waterproofing coating, potable-water approved, such as Nitocote CM210 or approved equivalent, to floors and walls, strictly in accordance with the manufacturer’s written instructions regarding surface preparation, priming, number of coats, minimum dry film thickness, curing, and protection. All pipe penetrations and exposed services within the tank to be treated with approved bituminous paint or compatible sealing system prior to application of the waterproofing coating. Item to include all materials, labor, tools, equipment, surface preparation, application, testing, protection, and completion of the works. Waterproofing system to be applied by the manufacturer or an approved authorized applicator, providing material and workmanship guarantees to the Employer. m2 38.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
HAYA VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.7-Site Works-Civil
1.1-Hard-scaping USD 0.00
1.2- Soft Scaping USD 0.00
2 Perimeter Fence with Gate USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 Hard-scaping
1.1.1 Clearing and grubbing of existing surface, including removal of vegetation, topsoil, and debris, to a depth of 40 cm and disposal as directed by the Engineer. m2 127.00 0.00
1.1.2 Selected fill to 95% MDD, including watering and rolling as shown the drawing m3 25.40 0.00
1.1.3 Supply, place, spread, water, and compact approved selected gravel material as capping layer to compound surface floor, including leveling, dressing to required camber/slope, and compaction to specified density as per specification and Engineer’s approval. m2 127.00 0.00
1.1.4 Supply and place crushed stone base course (C-4) 10 cm thick, including spreading, watering, and compaction to 95% MDD. m3 21.59 0.00
1.1.5 Supply, lay, and compact 7 cm thick Asphalt Binder Course using approved bituminous mix, laid in well-prepared and compacted layers over an approved base, in accordance with specifications and Engineer’s instructions. m2 127.00 0.00
1.1.6 Edge restraint using concrete curb (15 × 40 cm) including excavation, formwork, placing, and finishing. ml 53.00 0.00
1.1.7 Supply and install resin bound gravel surface comprising washed and dried natural aggregates mixed with UV-stable polyurethane resin, laid to specified thickness over a prepared and approved base, including finishing to a smooth, permeable, and durable surface in accordance with the specifications and Engineer’s instructions. m2 127.00 0.00
1.1.8 Supply and lay hand-dressed natural basalt/granite cobblestones (approx. 150×150×150 mm), tightly packed with joints filled with sand or cement-sand slurry as directed by the Engineer. The work shall includes all the necessary incidental works to complete the work such as surface preparation work. excavation, fill and cement sand slurry as per the detail Ar. drawing. The edge restaint curb stone measured in item 1.1.6. m2 13.13 0.00
Total Carried to Summary (USD) 0.00
1.2 Soft-soaping
1.2.1 Clearing and grubbing of existing surface, including removal of vegetation, topsoil, and debris, to a depth of 60 cm and disposal as directed by the Engineer. m3 37.80 0.00
1.2.2 Supply, place, spread, water, and lightly compact approved loamy (loam) soil for soft landscaping works, free from stones larger than 20 mm, roots, debris, weeds, and other deleterious materials, and suitable for plant growth. Loam soil shall have good drainage and adequate organic content, as approved by the Engineer. The rate shall include supply of soil, transportation, placement to the required levels and thicknesses, watering, light compaction, trimming, leveling, and all labor, tools, and equipment necessary to complete the work as specified. avg. depth 300mm m3 18.90 0.00
1.2.3 Supply, well decomposed animal manure or equivalent organic material to be mixed with the topsoil averagely 300mm and to use in backfilling of planting pits. Price shall include all the necessary works to complete the work. Provide 1kg sample and details of supplier With quotation for Landscape Architect’s approval. m3 18.90 0.00
1.2.4 Provide and plant grass as selected by the landscape architect. price includes grass as per the detail Architectural drawing. m2 63.00 0.00
1.2.5 Maintenance of lawn , grass, trees, shrubs, seasonal flower bed, other plantation and horticultural operations for weeding, watering, spreading of manure, good earth , fertilizers, spray of insecticides, fungicides, hoeing, pruning of tree/shrubs/hedge plants grassing garden swords, anti-termite treatment. Rates to include cost of material, all labor, tools & tackles, cost of manure, earth, fertilizer, pesticides etc. and also providing complete arrangement at site/sites for grass cutting by brand new power run lawn mower with skilled machine man & labor, diesel, lubricant to ensure mowing on barns and by manual labor through garden sward on the slop of under pass of the grass at least 3 times / month complete Month 2.00 0.00
1.2.6 Provide plants specially selected and nursery grown shade trees. Price supply of plants and planting as per the detail Architectural drawing. No 11.00 0.00
Total Carried to Summary (USD) 0.00
2 Galvanized Steel Wire Mesh Perimeter Fence with Gate
2.1 Supply, fabricate, and install galvanized steel wire mesh perimeter fence comprising 60 × 60 × 3 mm RHS vertical posts spaced at 2500 mm centers, fixed in concrete pad foundations, with top and bottom horizontal rails (60 × 60 × 3 mm RHS). The fence infill to be galvanized steel wire mesh (Ø 2.5 mm, 25 × 25 mm grid) securely fixed to the frame.The rate shall include excavation, concrete works, anti-rust treatment, metal painting, and provision of a main gate (2700 mm width) fabricated from similar materials, complete with all accessories, in accordance with specifications and Engineer’s instructions. ml 90.00 0.00
Total Carried to Summary (USD) 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
HAYA VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.8-Site Works-Electrical
ITEM DESCRIPTION UNIT QTY RATE TOTAL
1 Manhole for Electrical Systems
. Construct rectangular double red burnt brick electrical manholes of internal dimensions 800mm × 800mm × 700mm in accordance with the detail drawings and specifications. The manhole shall comprise 250mm thick double red burnt brick masonry walls, internally plastered with cement-sand mortar, a 100mm thick reinforced concrete base slab, and a 100mm thick removable reinforced concrete cover slab complete with flush-type cover, all as approved by the Engineer. The rate shall include excavation to the required depth, disposal/cart-away of surplus excavated material, back-filling and compaction around the structure, supply and placement of concrete, reinforcement, form-work, brick masonry, plastering, curing, and all associated civil works, labor, materials, tools, and incidentals necessary for the complete and proper construction and functioning of the electrical manhole system. Set 7.00 0.00
2 Light Fittings and Lamps 0.00
. Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing. IEC 60969 standards or equivalent and type approved 0.00
LED Solar Street Lights for Outdoor, atleast 15000 Lumens DA high-brightness, all-in-one solar street light for perimeter lighting, powered by sunlight with no electricity costs. Key Specifications Brightness: ≥15,000 lumens (bright as daylight) Light Type: LED (SMD 2835 or CREE 3030 chips) Color: Cool white (6000K–6500K) Solar Panel: 150-watt monocrystalline (charges in 6 hours) Battery: LiFePO4, ≥7-year lifespan, 3-day backup capacity. Operation: Dusk-to-dawn (auto on/off with daylight sensor) Motion sensor (full brightness on movement, dims to save energy) Remote control (adjust brightness, set timers) Weatherproof: IP65 (waterproof, dustproof, works in rain or heat) Material: Aluminum housing, tempered glass cover Runtime: 11 hours after 6-hour charge; up to 18 hours in dim mode Installation: Pole or wall mount (6ms height), no wiring needed Durability: Works in -22°F to 140°F; 50,000+ hour lifespan Warranty: 3–5 years No 8.00 0.00
3 Documentation 0.00
. Engineering, electrical installation as built drawings and O&M manuals. Qualified Set 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
HAYA VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.9-Site Works-Sanitary
SITE SANITARY WORKS
1 SITE WATER SUPPLY SYSTEMS USD 0.00
2 SITE WASTE WATER DRAINAGE SYSTEMS USD 0.00
3 ROOF & SURFACE RAIN WATER DRAINAGE SYSTEM USD 0.00
4 GENERAL ITEMS USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 WATER SUPPLY SYSTEMS
1.1 Site Water Supply Piping Systems
1.1.1 Supply,laying and test Cold drinking water pipes from municipality line to ground water tank(GWT). The pipe shall be PN16 DN50 High Density Polyethylene (HDPE) made of pure PE 100 rawmaterial and be laid in trench as shown in the sanitary site drawing. Provide 100mm thick sand bedding material rammed and tamped and 150mm thick approved material to cover the pipe all as per the typical site trench section and detail.Unit price shall include excavation, backfilling and cart away the excess quantity with all assistance civil works and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 10.00 0.00
1.1.2 Supply,laying and test Cold drinking water pipes from ground water tank(GWT) to transfer pump and to elevated water tank(EWT). The pipe shall be PN16 DN32 High Density Polyethylene (HDPE) made of pure PE 100 rawmaterial and be laid in trench as shown in the sanitary site drawing. Provide 100mm thick sand bedding material rammed and tamped and 150mm thick approved material to cover the pipe all as per the typical site trench section and detail.Unit price shall include excavation, backfilling and cart away the excess quantity with all assistance civil works and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 12.00 0.00
1.1.3 Supply,laying and test Cold drinking water pipes from gelevated water tank(EWT) to building block entrance where branched to water points (usable water supply)and nearby drainage lines (for overflow & washout piping). The pipe shall be PN10 DN40 PPR made of pure original rawmaterial and be laid in trench as shown in the sanitary site drawing. The unit price shall include piping bottom drain with valves piping system from EWT connected with overflow and connected to near by drainage ditch, air vent with insect screen and all support fixting work with related civil works. The unit price shall also consider and necessary fittings such as T branches, adapter, isolation valve, valve box, bends etc. where ever needed. All water pipes shall be tested according to the standard requirement at the expense of the contractor. lm 20.00 0.00
1.2 Supply and fix chrome service valves/isolation valve of approved standard before wet areas, or hand wash basins, water closets and other fixtures. Complete with unions, elastic water proofing, hand wheels of normal quality and with all other necessary accessories.
1.3 Construct standard a double brick wall,R.C base slab & R.C cover valve chamber compatible to valve size at specific position shown on the drawing with the respective PN6 bronze isolating valve.The price shall include excavation of a pit, cart away and backfilling.
1.3.1 Valve chamber with DN : variable isolation valves. № 4.00 0.00
1.4 Supply, installation, testing, and commissioning of domestic cold-water meter of multi-jet or volumetric type, suitable for potable water application in the animal health clinic water distribution system, complying with ISO 4064 / OIML R49 standards.Water meter shall be of DN50 nominal size, with brass or epoxy-coated ductile iron body, sealed dry dial register, and corrosion-resistant internal components. The meter shall be Class B or R80 accuracy, with a nominal working pressure of 16 bar, and maximum temperature 30°C.Each meter shall include couplings, strainer, and non-return valve, islation valve at each end and be installed in an accessible, ventilated, and protected meter chamber.All meters shall be factory-calibrated, certified, and permanently marked with serial number, flow class, size, and manufacturer identification. № 1.00 0.00
1.4 Water Reservoirs
1.4.1 Elevated water tank[EWT]
Supply, install, and commission a high-quality fiberglass (or equivalent) water tank with a nominal capacity of 2,500 liters for potable water storage, elevated 6 meters above ground on a support structure as per the provided sanitary and structural detail drawings. Tank Specifications: Material: Fiberglass reinforced plastic (FRP) or equivalent, approved for potable water storage, compliant with relevant standards ( BS EN 13280 or equivalent). Capacity: 2,500 liters (nominal). Design: Vertical seated(bottom diameter < 2m , suitable for external exposure with UV-resistant coating to withstand harsh weather conditions. Accessories: Manhole: Watertight manhole (minimum 600 mm diameter) with a lockable, weather-resistant cover to prevent contamination and ensure safety. Overflow Pipe: Minimum DN50, directed to a near by rain water drainage point with insect-proof mesh. Level Sensor: Automatic water level sensor/controller to start/stop the transfer pump. Inlet Pipe: Minimum DN32, fitted with a PN16 bronze gate valve. Outlet Pipe: Minimum DN40, fitted with a PN16 bronze gate valve and an expansion joint to accommodate to absorb any pipe movement. Drain Pipe: Minimum DN50, fitted with a PN16 bronze gate valve for complete tank drainage, directed to a designated drainage point. Fittings: All pipes and fittings shall be corrosion-resistant, suitable for potable water, and compliant with relevant standards (BS EN 545 or equivalent). Set 1.00 0.00
1.4.2 Ground water tank[GWT]
Supply, install, and commission a high-quality fiberglass (or equivalent) water tank with a nominal capacity of 5000 liters for potable water storage, at ground level as per the provided sanitary and structural detail drawings. Tank Specifications: Material: Fiberglass reinforced plastic (FRP) or equivalent, approved for potable water storage, compliant with relevant standards ( BS EN 13280 or equivalent). Capacity: 5000 liters (nominal). Design: Vertical seated(bottom diameter < 2m , suitable for external exposure with UV-resistant coating to withstand harsh weather conditions. Accessories: Manhole: Watertight manhole (minimum 600 mm diameter) with a lockable, weather-resistant cover to prevent contamination and ensure safety. Overflow Pipe: Minimum DN50, directed to a near by rain water drainage point with insect-proof mesh. Level Sensor: Automatic water level sensor/controller to start/stop the transfer pump. Inlet Pipe: Minimum DN50, fitted with a PN16 bronze gate valve. Outlet Pipe: Minimum DN32, fitted with a PN16 bronze gate valve and an expansion joint to accommodate to absorb any pipe movement. Drain Pipe: Minimum DN50, fitted with a PN16 bronze gate valve for complete tank drainage, directed to a designated drainage point. Fittings: All pipes and fittings shall be corrosion-resistant, suitable for potable water, and compliant with relevant standards (BS EN 545 or equivalent). set 1.00 0.00
1.5 Potable Cold Water Pumping system
1.5.1 Supply, fix, test and commission approved quality duplex vertical inline water pumps to push potable water to elevated water tanks to be distributed to every demanding buildings of the compound .As per the manufacturer's instruction and drawing shown . Price shall include all the necessary valves( one-way and stop valves), water hammer arrestor , common base plate ,automatic level control sensors & switches to start/off & to protect pumps from dry running & control panel .The price shall include all the necessary accessories required for the proper operation of the system but not specified or shown on the drawing. The pump shall be equiped with a single-phase transfer pump control board to manage water levels in an elevated water tank and ground water tank, featuring a compact IP65-rated enclosure (stainless steel or powder-coated mild steel), industrial-grade PLC, 4-inch touchscreen HMI for real-time monitoring and manual override, ultrasonic or float-type level sensors (2 nos. per tank) for accurate water level detection, control logic for automatic pump start/stop based on setpoints with sequential operation to minimize load, thermal overload relays, dry run protection via sensors or current monitoring, single-phase failure protection, surge arrestors, flame-retardant copper wiring, dedicated earthing, real-time pump status and alarm monitoring (high/low water levels, pump faults) on HMI, compliant with IEC standards and local regulations, complete with installation, testing, as-built drawings, operation manuals, training, and a 2-year warranty, designed for a 10-year operational life. Flow rate[LPS] = 0.694 @ 10 meter head Reference Model : Brand: DAB Model:KLPE 40-1200 with respective control systems and sensors. Set 1.00 0.00
1.5.2 SUPPLY, INSTALL, TEST & COMMISSION MUNICIPAL WATER CONNECTION TO GROUND WATER TANK Scope includes but not limited to: • Supply and installation of HDPE PE100 PN16 DN50 pipe (maximum 20 m total trench length from municipal main to groundwater tank inlet). • Supply and installation of municipality-approved water meter (DN50, with calibration certificate and serial number registration). • Supply and installation of isolation valve (gate/ball type, PN16, DN50, with flange or compression ends). • Supply and installation of all necessary fittings (elbows, tees, reducers, flanges, couplings, anchor blocks, thrust blocks, gaskets, bolts, and nuts). • Supply and installation of above-ground fence enclosure (galvanized steel or powder-coated mild steel) around the meter & valve assembly, with lockable access door, minimum 1.2 m height. • Excavation, backfilling, and compaction of trench (depth as per local municipality code, including sand bedding and warning tape). • Connection to municipal main (including tapping, saddle, or tee as required) and connection to tank inlet (with appropriate adapter). • Pressure testing (1.5x working pressure for minimum 24 hour), flushing, and chlorination/disinfection of pipeline. • All civil works (concrete pads for meter/fence posts, gravel base, and surface restoration to original condition). • All permits, inspections, and approvals from the local municipality (including meter registration and final sign-off). • As-built drawings and operation/maintenance manuals submission. Note: All materials shall be new, certified, and compliant with municipality standards. Contractor to verify all site dimensions and municipal point of connection prior to execution. ls 1.00 0.00
Total Carried to summary USD 0.00
2 WASTE WATER DRAINAGE SYSTEMS
2.1 Providing, laying and jointing of internal uPVC PN-10 waste pipes with all uPVC pipe fittings including jointing with solvent cement joints and testing of joints etc. according to where shown on the drawings.Complete with all the necessary fittings. Provide cleaning detail for all waste water riser pipes as per the detail drawing.
2.1.2 Diameter 110mm ml 14.00 0.00
2.1.3 Diameter 160mm ml 37.00 0.00
2.1.3 Diameter 300mm ml 14.00 0.00
2.1.4 Construct rectangular manhole out of 250mm thick double brick walls,internal dimension 600mm x 600mm x 850mm (average depth),internally plastered with three coats of cement/sand mix ratio1:3 ,on a base of precast R.C slab of size ,1300mm x 1300mm x100mm , including benching and bottom channeling with mass concrete.Slab shall be reinforced with dia.8mm reinforcement bar c/c 130mm bothways. Provide 150mm thick granular materials beneath the slab,on a compacted earth . Manhole shall have precast R.C cover slab, each,size, 740mm x 740mm x 100mmreinforced with diameter 8mm steel barc/c140mm bothways,including diameter 14mm steel ring handle with supporter bar all in accordance with the given detail drawings .Unit price shall include excavation of the pitto a depth of 800mm (average) and cart away of the excavated soil. № 8.00 0.00
2.1.5 Ditto No 2.1.4 but size(length x width x depth)[mm]= 400 x 400 x 400 gully trap for gray water drainage № 3.00 0.00
Total Carried to summary USD 0.00
3 ROOF WATER DRAINAGE SYSTEM
3.10 Construct a rectangular open channel designed to collect and convey storm water runoff from around the building perimeter. The channel is made of 20cm thick masonry bed, 40cm thick side masonry wall and whenever the walk way, ramp and car way crossing the top part will be covered with pre case concrete cover. The internal part of the channel shall be plastered. The work shall include excavation, cart away , fill, masonry bed, wall, plastering , pre-cast concrete cover at crossing and all incidental work to complete work as per the project’s detailed drawings. The channel longitudinal slope of 1% (1:100) shall be maintained. Where the natural ground slope exceeds 1%, the contractor shall follow the greater natural ground slope to ensure positive drainage and avoid ponding. ml 90.00 0.00
Minimum Ditch-: SIZE[mmXmm] = 225 X 200
3.20 Ditto No 2.1.3 but for roof and surface water drainage system. № 10.00 0.00
3.30 Ditto No 2.1.4 but for roof and surface water drainage system. № 2.00 0.00
3.40 SURFACE WATER DRAINAGE CONNECTION TO ROADSIDE DRAINAGE LINE Scope includes but is not limited to: • Supply and installation of DN300 uPVC pipe (Class/SN as per local municipality standard for underground non-pressure drainage) from the manhole inside the clinic compound to the roadside drainage line. Total length to be verified on-site. • Pipe shall be laid at a gradient of 0.5% to 1% (1 in 200 to 1 in 100) to ensure self-cleansing velocity and prevent siltation. • Connection to existing manhole inside clinic compound (600mm x 600mm internal size, with invert level above road side drainage invert). Includes breaking into manhole wall, making good, and providing a proper connection. • Connection to roadside drainage line (standard road side channel/drain). Includes forming a proper junction at the outfall point. The connecting pipe's invert level shall be set above the soffit (crown) of the roadside drain to prevent backflow during high-flow conditions in the main drain. • Supply and installation of all necessary fittings (bends, junctions, couplings, adaptors) as required for directional changes and connections. • All civil works: Excavation (including breaking existing surfaces), trenching, pipe bedding (sand/gravel), backfilling, compaction, and surface restoration to original condition. • Testing of the installed pipeline by means of water or air testing to ensure leak-tightness prior to backfilling. • All necessary permits, approvals, and inspections as required by the local municipality for connection to the public drainage system. Note: Contractor to verify all site levels, invert levels of the existing manhole and roadside drain, and confirm the required slope is achievable before commencement. All works to be carried out as per local municipality standards and approved drawings. ls 1.00 0.00
Total carried to summary USD 0.00
4 GENERAL ITEMS
4.1 Allow for Testing and commissioning of the entire plumbing installation by a Chartered Mechanical Engineer and obtaining a Test Certificate (3rd party testing to approval of the Engineer) including all off-site and factory testing; inspections to demonstrate compliance with relevant standards, operating the completed installation and submitting all relevant test records and authority approval. LS 1.00 0.00
4.2 All sanitary fittings supplied shall be provided with a minimum 5 year warranty, issued jointly and severally by the local supplier and the manufacturer. LS 1.00 0.00
4.3 Allow for preparation of Operationa and Maintenance Manual including site users training for the O & M Maual of all plumbing and mechanical appliances. LS 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
HAYA VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bill No.10-Signage
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 Directory Signs
Design, supply and install international standard Boy's, Girl's & PWD Toilet directional sign complete with pictogram (Girl's, Girl's & PWD toilet sign symbol) plus directional arrow that leading to the toilets. The sign shall also consist text “Boy's , Girl's & PWDToilet.” Sign shall be minimum size 300 mm × 400 mm, high quality tin: tin sign with retro design, metal tin, long-term use, not easy to damage, smooth surface, ...with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 1.00 0.00
2 Room Identication Signs
Design and supply signage with room number in accordance with this specification and as directed by the Architect. The material shall be made of 3-5mm thick wall mounted Acrylic signs. The size shall be 250mm x 30mm and letter height shall be 50-70mm for room number, 25-40mm room name letters and braille and tactile characters where applicable. The color and contrast between the text and background shall be high and the color shall be consistent with the veternary clinic branding (if any) or as per the Architect approval. The topography and information shall be Room number: Bold, large font (sans serif preferred), Room function/name: Smaller font beneath the number (e.g., Room 101 – Office) and Braille/tactile lettering placed below the printed text. The signage shall be fixed to the wall at 1.4–1.5 m above floor to centerline of sign on the latch side of the door, or directly on the door if wall space is not available and it shall be fixed with secure concealed fasteners or adhesive (depending on wall/door material). The supplier shall produce and submit Mock-ups for approval before mass production. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect.
2.1 Isolation Room No 1.00 0.00
2.2 Office No 1.00 0.00
2.3 X-ray room No 1.00 0.00
2.4 Preparation room No 1.00 0.00
2.5 Electric Room No 1.00 0.00
2.6 Rest rooms and Janitors with pictogram of gents, ladies and PWD No 4.00 0.00
2.7 Treatment room No 1.00 0.00
2.8 laboratory No 1.00 0.00
3 Safety and Compliance Signs
4.1 Design, supply and install Emergency Exit Sign in accordance with this specification and as directed by the Architect. The material shall be made of flame-retardant, impact-resistant ABS clear acrylic plate and shall comply with BS EN ISO 7010 Exit Symbol (E001) and shall have Multi-installation system: Hanging, wall or surface mounted depending on the location. The size of the letter height shall be minimum 150mm with a stroke width 19mm, color contrast to be white letters on green background and the sign shall consist pictogram of running man symbol + directional arrow that leading to exit doors depending the location of the Emergency sign plan on the drawing. The sign shall support internally illuminated and visible in smoke and low light and are powered by dual power 220-240V AC (primary), automatic 90 minutes minimum battery backup (Lithium-ion battery).The sign shall be fixed to exist access point at 2.00–2.50 m above floor level. The supplier shall produce and submit Mock-ups for approval before mass production or procurement. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect. No 4.00 0.00
4.2 Design, supply and install Entrance Sign in accordance with this specification and as directed by the Architect. The material shall be made of flame-retardant, impact-resistant ABS clear acrylic plate and shall comply with BS EN ISO 7010 Exit Symbol (E001) and shall have Multi-installation system: Hanging, wall or surface mounted depending on the location. The size of the letter height shall be minimum 150mm with a stroke width 19mm, color contrast to be white letters on green background and the sign shall consist text+ directional arrow that leading to entrance.The sign shall be fixed to entrance access point at 2.00–2.50 m above floor level. The supplier shall produce and submit Mock-ups for approval before mass production or procurement. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect. No 3.00 0.00
4.3 Supply and fix 3mm rigid PVC/acrylic Fire Extinguisher sign (300mm x 100mm) with 50mm high ISO-compliant white lettering on red background, including all fixings and installation. No 7.00 0.00
4.4 Supply directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. Supply and install directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. No 1.00 0.00
4.5 Supply emergency assembly point safety sign complete with standard ISO 7010 pictogram (E007: four people symbol) and text “EMERGENCY ASSEMBLY POINT.” Sign shall be fabricated from 3 mm thick photo luminescent rigid PVC or aluminum composite panel, minimum size 600 mm × 600 mm, with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
HAYA VETERNARY PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.10-Day Works
1 LABOUR USD 0.00
2 MATERIAL USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
(ALL PROVISIONAL)
In accordance with the Conditions of Contract, the Contractor will be paid day work rates for extra work that cannot properly be measured and valued, and the Contractor is to insert in the space provided below the basic rates and costs of labour,materials and plant as described hereunder:-
1.1 MASON hours 1 0.00
1.2 CARPENTER hours 1 0.00
1.3 SCAFFOLDER hours 1 0.00
1.4 JOINER hours 1 0.00
1.5 PLUMBER hours 1 0.00
1.6 ELECTRICIAN hours 1 0.00
1.7 PLASTERER hours 1 0.00
1.8 PAINTER hours 1 0.00
1.9 LABOURER hours 1 0.00
TOTAL in USD 0.00
1.10 To the basic net rates of labor used for work carried out on day works, an addition 25% percent which is to include for task work and incentive schemes, tools, standing, scaffolding, supervision, insurance, transport profit and overheads.
To collection of Labour Day works 0.00
2.1 Cement Per Tonne 1 0.00
2.3 Aggregate (grade 25 - 5mm) m3 14 0.00
2.4 Steel reinforcement
(i) Mild steel bar Kg 1 0.00
(ii) High tensile bar Kg 1 0.00
2.5 Timber formwork Per SQ.M 1 0.00
2.6 Paint, Gloss Per 4 Litres 1 0.00
2.7 Paint, Emulsion Per 4 Litres 1 0.00
2.8 Mahogany Varnish Per 4 Litres 1 0.00
2.9 100mm diameter uPVC rainwater downpipe 6M Per Each 1 0.00
2.10 Ditto bends Per Each 1 0.00
2.11 Ditto offsets Per Each 1 0.00
2.12 Ditto watershoe Per Each 1 0.00
2.13 Fixing brackets Per Each 1 0.00
2.14 Fixing screws Per Packet 1 0.00
2.15 75mm thick x 375mm wide weather/throated cills Per M 1 0.00
2.16 4 mm Clear sheet glass Per SQ.M. 1 0.00
2.17 100mm long Flush bolt Per Each 1 0.00
2.18 Indicator Signage Per Each 1 0.00
2.19 400mm x 200mm x 100mm hollow concrete blocks Per 1000 1 0.00
2.20 300mm x300mm x 8mm Ceramic floor tiles Per SQ.M. 1 0.00
2.21 150mm x 150mm x 6mm white glazed wall tiles Per SQ.M. 1 0.00
2.22 25mm x 3mm earth copper tape Per M 1 0.00
2.23 35mmsq bare copper cable Per M 1 0.00
2.24 6mmsq bare copper cable Per M 1 0.00
2.25 2.5mmsq. TWE copper cable Per M 1 0.00
2.26 2.5mmsq. SC PVC-I copper cable Per M 1 0.00
2.27 4.0mmsq. SC PVC-I copper cable Per M 1 0.00
2.28 10.0mmsq. 3C PVC-SWA-PVC copper cable Per M 1 0.00
2.29 20mm diameter galvanised steel tubing 6M Per M 1 0.00
2.30 20mm diameter galvanised steel tee Per Each 1 0.00
2.31 20-15mm diameter reducer Per Each 1 0.00
2.32 110mm diameter uPVC soil pipe 6M Per Each 1 0.00
2.33 50mm ditto waste pipe 6M Per Each 1 0.00
2.34 110mm ditto single branch access Per Each 1 0.00
2.35 50mm ditto sweep tee Per Each 1 0.00
2.36 Single bowl, single drainer stainless steel sink size 2000 x 600mm Per Each 1 0.00
To Collection 0.00
2.37 To the basic nett rates of materials used for work carried out on dayworks, an addition of 25% which is to include for unloading and storing as necessary, the use of hand plant, and machinery etc. available on site, profit and overheads.
To collection of Material Day works 0.00
3.1 Portable Compressor with 2 breakers or equivalent with 1500 mm hoses and reels hours 40 0.00
3.2 Damp Truck (0.75 tonne) hours 40 0.00
3.3 Lorry seven tonne tipper hours 40 0.00
3.4 Concrete Mixer (14/10) complete for weight batch mixing hours 40 0.00
3.5 50 mm self priming centrifugal pump with hose and ancillary equipment hours 40 0.00
3.6 Concrete Vibrators hours 40 0.00
To Collection 0.00
3.7 To the basic rates of plant used for work carried out on dayworks, an addition of 25% per cent, which is to include for driver and/or attendance, fuel and consumable stores supervision, insurance, road licence,profit and overheads.
To collection of Plant Day works 0.00
Name of Signatory:
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Exavation Work
ITEM TYPE SIZE No M3
Exavation & Earthwork
1.01 site clear
cad area including appron,ditch
1.02. Bulk Excavation to reduce level
1.03. Footing Excavation
1.04. ditto but from 1.50-3.00m
1.05.Trench Excavation
with 0.15 allowance each side
1.05. Back fill under hard core
ddt stone masonry wall
1.06.Ditto but around footing
Excavation Volume
ddt lean concrete
ddt footing pad
ddt column 0.00
1.07.Ditto but around masonry
with 0.25 allowance each side
1.08. Cart away
1.09. hard core
1.10. Dewatering
3.01. construction joint
10mm thich joint filler/sila or fiber board
4. Masonry Item
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Sub-Structure Concrete
CONCRETE FORM WORK
Type Size No Total Size Total
2.1. Lean Concrete
Total 118.86 m2
Under masonry wall
Under hard core
2.2 C -25 CONCRETE
Foundation Column
Total 5.04 67.20
200mm thick slab
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Super-Structure Concrete
CONCRETE FORM WORK
1.1. C-250 Concrete
A. Elevation Column
From Ground-roof floor
150mm Concrete gutter
Total 9.05 m3 129.05 m2
100mmSun breaker
Total 22.11 m3 23.32 m2
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Sep 28,2025
Bill No.-2-Staff Residence Block Architectural
ITEM TYPE SIZE No Total
2.01. 20cm thick H.C.B wall screening
2.01. 20cm thick H.C.B wall
ddt opening 0.00
3. Roofing Work
3.04. Valley gutter
Gutter light wt concrete
Gutter water proofing
B. Steel Structure Beam
C. RHS Truss system
C.1 RHS 60 x 60 x 3mm upper and lower member
Total length 188.60
Unit Wt. for the section 5.37
Total Kg 1,012.67
C.2 RHS 50 x 50 x 3mm upper and lower member
Total length 24.00
Unit Wt. for the section 4.43
Total Kg 106.26
C.3 RHS 40 x 40 x 3mm Diagonal & verical member
Total length 181.85
Unit Wt. for the section 3.49
Total Kg 633.82
D.1 80 x 4 x 3mm fixed
Total length 434.10
Unit Wt. for the section 5.37
Total Kg 2,330.86
Base plate 200 x 200 x 6mm
Total plate 56.00
7. Finishing work
6.0 Two coats of plastering
Internal HCB wall plastering
to receive gypsum chuck
ddt opening 0.00
External plastering
ddt opening 0.00
Bill No.2 Staff Residence Block
For Ariya kayisa Primary School
Summary of Reinforcement for Sub-structures & Super-Srructure
Foundation Footing
Foundation Column
Ground Floor Beam
Ground Floor Slab
Super-Structure
Elevation Column
REINFORCING BAR SCHEDULE
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Date , Sep 28,2025
Bill No.-2-Staff Residence Block Consultant;- UNOPS-ETMCO
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Foundation Colum --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Foundation Column --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Ground floor slab --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
internal partiton area --- --- --- --- --- --- --- ---
REINFORCING BAR SCHEDULE
Project :-Ariya Kayisa Primary School Location:- South Omo, SSSP
Employer :- Date , Sep 28,2025
Bill No.-2-Staff Residence Block Consultant;- UNOPS-ETMCO
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Elevation Column --- --- --- --- --- --- --- ---
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Item Position Dia (mm) No. of bars No of bar member Length 6 8 10 12 14 16 20 24
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
01- LOT 01 PORTSUDAN VETERINARY_TECHNICAL DRAWING.dwg
Bidding document • 6.66 MB
01- LOT 02 AWLEEB & GUNUB VETERINARY_MECHANICAL TECHNICAL DRAWING.dwg
Bidding document • 16.31 MB
01- LOT 03 SAWAKIN VETERINARY_MECHANICAL TECHNICAL DRAWING.dwg
Bidding document • 13.35 MB
01- LOT 04 TOKER VETERINARY_TECHNICAL DRAWING.dwg
Bidding document • 10.41 MB
01- LOT 05 HAYA VETERINARY_TECHNICAL DRAWING.dwg
Bidding document • 11.74 MB
02- LOT 01 PORTSUDAN WATER RESERVOIR PLATFORM.dwg
Bidding document • 1.08 MB
02- LOT 02 AWLEEB & GUNUB WATER RESERVOIR PLATFORM.dwg
Bidding document • 1.07 MB
02- LOT 04TOKER WATER RESERVOIR PLATFORM.dwg
Bidding document • 1.04 MB
02- LOT 05 HAYA WATER RESERVOIR PLATFORM.dwg
Bidding document • 1.06 MB
02-LOT 03 SAWAKIN WATER RESERVOIR PLATFORM.dwg
Bidding document • 1.33 MB
03- LOT 02 AWLEEB & GUNUB SEPTIC TANK & SOAKAWAY PIT.dwg
Bidding document • 1.03 MB
03- LOT 03 SAWAKIN SEPTIC TANK & SOAKAWAY PIT.dwg
Bidding document • 1.03 MB
03- LOT 04 TOKER SEPTIC TANK & SOAKAWAY PIT.dwg
Bidding document • 1.01 MB
03- LOT 05 HAYA SEPTIC TANK & SOAKAWAY PIT.dwg
Bidding document • 1.01 MB
03-LOT 01 PORTSUDAN SEPTIC TANK & SOAKAWAY PIT.dwg
Bidding document • 1.01 MB
04- LOT 01 PORTSUDAN CATTLE WASTE HOLDING TANK.dwg
Bidding document • 0.52 MB
04- LOT 02 AWLEEB & GUNUB CATTLE WASTE HOLDING TANK.dwg
Bidding document • 0.52 MB
04- LOT 04 TOKER CATTLE WASTE HOLDING TANK.dwg
Bidding document • 0.52 MB
04-LOT 03 SAWAKIN CATTLE WASTE HOLDING TANK.dwg
Bidding document • 0.52 MB
04-LOT 05 HAYA CATTLE WASTE HOLDING TANK.dwg
Bidding document • 0.52 MB
05- LOT 01 PORTSUDAN DETAILS.dwg
Bidding document • 0.99 MB
05- LOT 02 AWLEEB & GUNUB DETAILS.dwg
Bidding document • 0.98 MB
05- LOT 03 SAWAKIN DETAILS.dwg
Bidding document • 0.98 MB
05- LOT 04 TOKER DETAILS.dwg
Bidding document • 0.96 MB
05- LOT 05 HAYA DETAILS.dwg
Bidding document • 0.96 MB
ITB_2026_65359 Small Works - 6 Solicitation - ITB 04 Sections II, III, IV, V (1).docx.pdf
Bidding document • 0.91 MB
ITB_2026_65359 Small Works - 6 Solicitation - ITB 02 Particulars.docx.pdf
Bidding document • 0.30 MB
ITB_2026_65359 Small Works - 6 Solicitation - ITB 05 Section VI - .docx
Bidding document • 0.61 MB
ITB202665359 Small Works - 6 Solicitation - ITB 03 Section I - Instructions to Bidders.pdf
Bidding document • 2.21 MB
LOT 01 2026.08.13_PORT SUDAN VETERINARY UNIT_ELECTRICAL_R1..pdf
Bidding document • 5.86 MB
LOT 01 2026.08.13_PORT SUDAN VETERINARY UNIT_ELECTRICAL_R1.dwg
Bidding document • 15.99 MB
LOT 01 2026.08.13_PORT SUDAN VET UNIT_ARCHITECTURAL_R1.dwg
Bidding document • 15.36 MB
LOT 01 20260607 Electrical Design Report EFSR PORT SUDAN R2.pdf
Bidding document • 1.19 MB
LOT 01 2026-08-14_PORT SUDAN VET UNIT_ARCHITECTURAL_R1.PDF
Bidding document • 9.51 MB
LOT 01 Civil Spec.pdf
Bidding document • 0.74 MB
LOT 01 Geotechnical _ Soil Investigations and Topographic Survey .docx.pdf
Bidding document • 13.14 MB
LOT 01 Port Sudan Veterinary Clinic ST Design Drawing.dwg
Bidding document • 3.59 MB
LOT 01 Port Sudan Veterinary Clinic ST Design Drawing.pdf
Bidding document • 3.23 MB
LOT 01 Port Sudan Veterinary Clinic ST Design Report.pdf
Bidding document • 18.92 MB
LOT 01 PORTSUDAN SANITARY DESIGN REPORT FOR SUDAN ANIMAL HEALTH CENTER.pdf
Bidding document • 1.79 MB
LOT 01 PORTSUDAN VETERNARY MECHANICAL LAYOUT.pdf
Bidding document • 5.05 MB
LOT 01 Septic Tank.dwg
Bidding document • 0.91 MB
LOT 01 Technical Specifications C-Mechanical & Sanitary Works.pdf
Bidding document • 0.51 MB
LOT 01 Water Reservoir Platform.dwg
Bidding document • 1.02 MB
LOT 01bTechnical_Specification_for_Electrical_Work_ EFSR PORT SUDAN R2.pdf
Bidding document • 0.46 MB
LOT 01cCattle Waste Tank.dwg
Bidding document • 0.87 MB
LOT 02 2026.08.13_AWLEEB & GUNUB VET UNIT_ELECTRICAL_R1.PDF
Bidding document • 5.99 MB
LOT 02 2026.08.13_AWLEEB & GUNUB VETERINARY UNIT_ELECTRICAL_R1.dwg
Bidding document • 13.96 MB
LOT 02 2026-07-10_AL WALEEB & GUNUB VET UNIT_ARCHITECTURAL_R1.dwg
Bidding document • 14.20 MB
LOT 02 20260711 Electrical Design Report EFSR GUNUB R2.pdf
Bidding document • 1.19 MB
LOT 02 20260711_Technical_Specification_for_Electrical_Work_ EFSR GUNUB R2.pdf
Bidding document • 0.45 MB
LOT 02 2026-08-14_AL WALEEB & GUNUB VET UNIT_ARCHITECTURAL_R1.PDF
Bidding document • 7.76 MB
LOT 02 Al Walleb & Gunub Veterinary Clinic ST Design Drawing.pdf
Bidding document • 3.27 MB
LOT 02 Al Walleb & Gunub Veterinary Clinic ST Design Report.pdf
Bidding document • 18.92 MB
LOT 02 Al Walleb & Gunub Veterinary Unit ST Design Drawing.dwg
Bidding document • 3.66 MB
LOT 02 AWLEEB & GUNUB SANITARY DESIGN REPORT FOR ANIMAL HEALTH CENTER.pdf
Bidding document • 1.78 MB
LOT 02 AWLEEB & GUNUB VETERNARY MECHANICAL (1).pdf
Bidding document • 5.09 MB
LOT 02 AWLEEB & GUNUB VETERNARY MECHANICAL.pdf
Bidding document • 5.09 MB
LOT 02 Cattle Waste Tank.dwg
Bidding document • 0.90 MB
LOT 02 Civil Spec.pdf
Bidding document • 0.74 MB
LOT 02 Geotechnical _ Soil Investigations and Topographic Survey .docx.pdf
Bidding document • 13.14 MB
LOT 02 Septic Tank.dwg
Bidding document • 0.91 MB
LOT 02 Technical Specifications C-Mechanical & Sanitary Works (1).pdf
Bidding document • 0.51 MB
LOT 02 Water Reservoir Platform.dwg
Bidding document • 1.02 MB
LOT 03 2026.08.13_SAWAKIN VET UNIT_ELECTRICAL_R1.PDF
Bidding document • 5.94 MB
LOT 03 2026.08.13_SWAKINI VETERINARY UNIT_ELECTRICAL_R1.dwg
Bidding document • 14.50 MB
LOT 03 20260711 Electrical Design Report EFSR SWAKINI R2.pdf
Bidding document • 1.19 MB
LOT 03 20260711_Technical_Specification_for_Electrical_Work_ EFSR SWAKINI R2.pdf
Bidding document • 0.45 MB
LOT 03 2026-07-23_SAWAKIN VET UNIT_ARCHITECTURAL_R1.dwg
Bidding document • 8.69 MB
LOT 03 2026-08-14_SAWAKIN VET UNIT_ARCHITECTURAL_R1.PDF
Bidding document • 7.47 MB
LOT 03 Cattle Waste Tank.dwg
Bidding document • 0.87 MB
LOT 03 Civil Spec.pdf
Bidding document • 0.74 MB
LOT 03 Geotechnical _ Soil Investigations and Topographic Survey .docx.pdf
Bidding document • 13.14 MB
LOT 03 Sawakin Veterinary Unit ST Design Drawing.dwg
Bidding document • 3.12 MB
LOT 03 SAWAKIN SANITARY DESIGN REPORT FOR ANIMAL HEALTH CENTER.pdf
Bidding document • 1.80 MB
LOT 03 Sawakin Veterinary Clinic ST Design Drawing.pdf
Bidding document • 3.16 MB
LOT 03 Sawakin Veterinary Clinic ST Design Report.pdf
Bidding document • 18.92 MB
LOT 03 SAWAKIN VETERINARY_MECHANICAL TECHNICAL DRAWING-MODEL VETERINARY SN-merged.pdf
Bidding document • 5.07 MB
LOT 03 Septic Tank.dwg
Bidding document • 0.91 MB
LOT 03 Technical Specifications C-Mechanical & Sanitary Works (1).pdf
Bidding document • 0.51 MB
LOT 03 Water Reservoir Platform.dwg
Bidding document • 1.02 MB
LOT 04 2026.08.13_TOKER VET UNIT_ELECTRICAL_R1.PDF
Bidding document • 5.97 MB
LOT 04 2026.08.13_TOKER VETERINARY UNIT_ELECTRICAL_R1.dwg
Bidding document • 13.91 MB
LOT 04 20260607 Electrical Design Report EFSR TOKER R2.pdf
Bidding document • 1.21 MB
LOT 04 20260607_Technical_Specification_for_Electrical_Work_ EFSR TOKER R2.pdf
Bidding document • 0.45 MB
LOT 04 2026-08-13_TOKER VET UNIT_AR.dwg
Bidding document • 8.34 MB
LOT 04 2026-08-14_TOKER VET UNIT_ARCHITECTURAL_R1.PDF
Bidding document • 7.87 MB
LOT 04 Cattle Waste Tank.dwg
Bidding document • 0.87 MB
LOT 04 Civil Spec.pdf
Bidding document • 0.74 MB
LOT 04 Geotechnical _ Soil Investigations and Topographic Survey .docx.pdf
Bidding document • 13.14 MB
LOT 04 Septic Tank.dwg
Bidding document • 0.91 MB
LOT 04 Technical Specifications C-Mechanical & Sanitary Works (1).pdf
Bidding document • 0.51 MB
LOT 04 Tokar Veterinary Clinic ST Design Drawing.dwg
Bidding document • 3.71 MB
LOT 04 Tokar Veterinary Clinic ST Design Drawing.pdf
Bidding document • 4.22 MB
LOT 04 TOKER SANITARY DESIGN REPORT FOR ANIMAL HEALTH CENTER.pdf
Bidding document • 1.79 MB
LOT 04 TOKER VETERNARY MECHANICAL LAYOUT DRAWINGS.pdf
Bidding document • 5.06 MB
LOT 04 Water Reservoir Platform.dwg
Bidding document • 1.02 MB
LOT 05 2026.08.13_HAYA VET UNIT_ARCHITECTURAL_R1.dwg
Bidding document • 14.03 MB
LOT 05 2026.08.13_HAYA VET UNIT_ELECTRICSL_R1.PDF
Bidding document • 5.92 MB
LOT 05 2026.08.13_HAYA VETERINARY UNIT_ELECTRICAL_R1.dwg
Bidding document • 14.05 MB
LOT 05 20260607 Electrical Design Report EFSR HAYA R2.pdf
Bidding document • 1.24 MB
LOT 05 20260711_Technical_Specification_for_Electrical_Work_ EFSR HAYA R2.pdf
Bidding document • 0.46 MB
LOT 05 2026-08-14_HAYA VET UNIT_ARCHITECTURAL_R1.PDF
Bidding document • 7.80 MB
LOT 05 Cattle Waste Tank.dwg
Bidding document • 0.90 MB
LOT 05 Civil Spec.pdf
Bidding document • 0.74 MB
LOT 05 Geotechnical _ Soil Investigations and Topographic Survey .docx.pdf
Bidding document • 13.14 MB
LOT 05 Haiya Veterinary Clinic ST Design Report.pdf
Bidding document • 18.92 MB
LOT 05 HAYA SANITARY DESIGN REPORT FOR ANIMAL HEALTH CENTER.pdf
Bidding document • 1.80 MB
LOT 05 Haya Veterinary Clinic ST Design Drawing.dwg
Bidding document • 3.35 MB
LOT 05 Haya Veterinary Clinic ST Design Drawing.pdf
Bidding document • 3.20 MB
LOT 05 HAYA VETERNARY MECHANICAL LAYOUT DARWING.pdf
Bidding document • 5.07 MB
LOT 05 Septic Tank.dwg
Bidding document • 0.91 MB
LOT 05 Technical Specifications C-Mechanical & Sanitary Works (1).pdf
Bidding document • 0.51 MB
LOT 05 Water Reservoir Platform.dwg
Bidding document • 1.03 MB
LOT 1 - Port Sudan-Veterinary Clinic- Unpriced BoQ-16-August.-2026.pdf
Bidding document • 0.79 MB
LOT 1 - Port Sudan-Veterinary Clinic- Unpriced BoQ-16-August.-2026.xlsx
Bidding document • 2.02 MB
LOT 2 - Al Waleeb & Gunub-Veterinary Clinic- Unpriced BoQ-16-Aug.-2026.pdf
Bidding document • 0.78 MB
LOT 2 - Al Waleeb & Gunub-Veterinary Clinic- Unpriced BoQ-16-Aug.-2026.xlsx
Bidding document • 2.02 MB
LOT 3 - Sawakin-Veterinary Clinic- Unpriced BoQ-16-Aug.-2026.pdf
Bidding document • 1.53 MB
LOT 3 - Sawakin-Veterinary Clinic- Unpriced BoQ-16-Aug.-2026.xlsx
Bidding document • 1.97 MB
LOT 4 - Tokar-Veterinary Clinic- Unpriced BoQ-16-Aug.-2026.pdf
Bidding document • 1.52 MB
LOT 4 - Tokar-Veterinary Clinic- Unpriced BoQ-16-Aug.-2026.xlsx
Bidding document • 1.97 MB
LOT 5 - Haya-Veterinary Clinic- Unpriced BoQ-16-Aug.-2026.pdf
Bidding document • 0.79 MB
LOT 5 - Haya-Veterinary Clinic- Unpriced BoQ-16-Aug.-2026.xlsx
Bidding document • 2.02 MB
LOT Small Animal Health Unit_EFSR_SUDAN_compressed (1).pdf
Bidding document • 1.76 MB
Notice on UNGM.html
Notice page • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .