Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
Bid Security (EMD)
Refer Docs
Closing Date
5 Dec 2026, 06:30 (UTC)5 Dec 2026, 12:00 pm IST
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender description: Supply and Delivery of Electrical Equipment and Materials for UNOPS Afghanistan ----- IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
322991
ITB/2026/65471
Invitation to bid
Afghanistan
INVITATION
UTC
21 Nov 2026
18 Nov 2026
Supply and Delivery of Complete 40-ft High-Cube Containerized Cold Storage Unit
Supply and Delivery of 20 ft High Cube connnex container for electrical equipment
[insert RFQ reference number]
[insert name of bidder]
[insert submission date]
Bidder to complete
Details of goods offered. Bidder to complete
40 ft Containerized Cold Storage Unit | Unit: Set
KEY TECHNICAL REQUIREMENTS
Container size / construction
Walls and ceiling insulation
Insulated flooring
Complete refrigeration plant
Cooling duty / capacity
Temperature / humidity control
Cold-room access / ventilation
Electrical and personnel safety
Turnkey completion / acceptance
20 ft connnex container for electrical equipment | Unit: Set
KEY TECHNICAL REQUIREMENTS
Container structure / use
Air-conditioning
Safe installation arrangement
☐ Yes ☐ No
[insert full name of bidder]
[insert title]
[insert submission date]
[insert signature]
[bidder to insert]
[bidder to insert]
[bidder to insert]
UNOPS WERP Warehouse, end of Pule Charkhi Industrial Park, PD9, Kabul, Afghanistan
Description of item
Supply and Delivery of Poultry House Structure
Supply and Delivery of Egg Incubator & Hatcher
Supply and Delivery of Tunnel Fans
Supply and Delivery of Electrical Heaters
Supply and Delivery of Submersible Water Pumps
Supply and Delivery of Hatchery Lighting
Supply and Delivery of Small-Power Package
Supply and Delivery of Temperature & Humidity Monitoring Devices
Supply and Delivery of Complete Hatchery Feed Distribution System
Supply and Delivery of Complete Hatchery Water, Drinking & Medication System
Supply and Delivery of Hatchery Weighing & Disinfection Equipment Package
Supply and Delivery of 40-Foot Storage Container
[insert RFQ reference number]
[insert name of bidder]
[insert submission date]
Bidder to complete
Details of goods offered. Bidder to complete
Poultry House Structure | Unit: No.
KEY TECHNICAL REQUIREMENTS
Dimensions / construction
Connections / foundation interfaces
Roof / finishes / scope
Egg Incubator & Hatcher | Unit: No.
KEY TECHNICAL REQUIREMENTS
Type / automation
Egg capacity
Electrical rating / completeness
Tunnel Fans | Unit: No.
KEY TECHNICAL REQUIREMENTS
Airflow capacity
Electrical supply
Electrical Heaters | Unit: No.
KEY TECHNICAL REQUIREMENTS
Heating output
Controls / protection
Submersible Water Pumps | Unit: No.
KEY TECHNICAL REQUIREMENTS
Rated motor power
Pump duty / electrical compatibility
Controls / completeness
Hatchery Lighting | Unit: Set.
KEY TECHNICAL REQUIREMENTS
Lighting configuration
Installation completeness
Small-Power Package | Unit: Lot.
KEY TECHNICAL REQUIREMENTS
Scope / socket outlets
Electrical installation completeness
Temperature & Humidity Monitoring Devices | Unit: Set.
KEY TECHNICAL REQUIREMENTS
Measurement functions
Readout / suitability
Complete Hatchery Feed Distribution System | Unit: Lot.
KEY TECHNICAL REQUIREMENTS
Feeding configuration
Feeder configuration
Accessories / operation
Complete Hatchery Water, Drinking & Medication System | Unit: Lot.
KEY TECHNICAL REQUIREMENTS
Drinking / transfer configuration
Water storage / filtration
Medication delivery
Hatchery Weighing & Disinfection Equipment Package | Unit: Lot.
KEY TECHNICAL REQUIREMENTS
Weighing equipment
Disinfection equipment
40-Foot Storage Container | Unit: No.
KEY TECHNICAL REQUIREMENTS
Type / construction
Internal fit-out
☐ Yes ☐ No
[insert full name of bidder]
[insert title]
[insert submission date]
[insert signature]
[bidder to insert]
[bidder to insert]
[bidder to insert]
UNOPS WERP Warehouse, end of Pule Charkhi Industrial Park, PD9, Kabul, Afghanistan
Description of item
50 kW Three-Phase Hybrid Solar Inverter with All Standard Accessories
15 kW Three-Phase Hybrid Solar Inverter with Standard Accessories
HV LiFePO4 Battery Cabinet with DC Protection Panel and Standard Accessories
LiFePO4 Battery Storage Modules with Structural Steel Battery Cabinets/Racks
Central Master Battery Management System (BMS) & DC Safety Protection Switchboard for 64 LiFePO4 Battery Modules
AC power cable – 4C × 35 mm²
AC power cable – 4C × 120 mm²
AC power cable – 4C × 95 mm²
Solar PV string cable – 1C × 6 mm², 1500 V DC
Battery DC cable – 95 mm² copper (single-core basis)
PV DC combiner / independent string-protection boxes
Outdoor PV DC load-break isolator – 2P, 1500 V, 25 A
Main LV distribution board (MDB) – 630 A Cu busbar
Hatchery load distribution board – 250 A Cu busbar
Cold-store distribution panel A – 125 A Cu busbar
Auxiliary AC distribution board – 64 A main
Main AC inverter / grid distribution switchboard – 63/80 A feeders
Industrial inverter/BMS/EMS communication cable
Smart energy manager / inverter coordination package
Rigid uPVC electrical conduit – Ø50 mm
Flexible metallic liquid-tight electrical conduit – Ø32 mm
Galvanized cable tray/ladder – 200 mm width
Galvanized cable tray/ladder – 300 mm width
Underground cable-route markers / warning tape
Insulated green/yellow earth bonding conductor – 16 mm²
Complete Site Earthing & Lightning Protection System
Portable ABC fire extinguisher – 5 kg
[insert RFQ reference number]
[insert name of bidder]
[insert submission date]
Bidder to complete
Details of goods offered. Bidder to complete
50 kw Hybrid inverter with all standard accessories | Unit: No.
KEY TECHNICAL REQUIREMENTS
Rated AC output
Solar MPPT
Hybrid / parallel operation
Battery interface / metering
15 kW Three-Phase Hybrid Solar Inverter with Standard Accessories, Energy Meter and EMS | Unit: Unit
KEY TECHNICAL REQUIREMENTS
Power / AC output
PV input / MPPT
Battery DC compatibility
Efficiency / protection / warranty
Control / communications
HV LiFePO4 Battery Cabinet with DC Protection Panel and Standard Accessories | Unit: No.
KEY TECHNICAL REQUIREMENTS
Battery chemistry / capacity
DC electrical rating / enclosure
Integrated safety / communication
DC isolation / inverter coordination
LiFePO4 Battery Storage Modules with Structural Steel Battery Cabinets/Racks | Unit: Pcs
KEY TECHNICAL REQUIREMENTS
Module chemistry / energy rating
Cycle life / temperature
Module BMS / safety
Rack / documentation / warranty
Central Master Battery Management System (BMS) & DC Safety Protection Switchboard for 64 LiFePO4 Battery Modules | Unit: Set
KEY TECHNICAL REQUIREMENTS
Master BMS integration
DC protection
Protection design verification
AC power cable – 4C × 35 mm² | Unit: m
KEY TECHNICAL REQUIREMENTS
Conductor cross-section / material
Insulation / voltage / standard
Feeder performance
AC power cable – 4C × 120 mm² | Unit: m
KEY TECHNICAL REQUIREMENTS
Conductor cross-section / material
Insulation / voltage / standard
Feeder performance
AC power cable – 4C × 95 mm² | Unit: m
KEY TECHNICAL REQUIREMENTS
Conductor cross-section / material
Insulation / voltage / standard
Feeder performance
Solar PV string cable – 1C × 6 mm², 1500 V DC | Unit: m
KEY TECHNICAL REQUIREMENTS
Conductor cross-section / material
Insulation / DC rating
PV installation suitability
Battery DC cable – 95 mm² copper (single-core basis) | Unit: m
KEY TECHNICAL REQUIREMENTS
Conductor cross-section / material
Voltage / insulation rating
DC cable performance
PV DC combiner / independent string-protection boxes | Unit: Set
KEY TECHNICAL REQUIREMENTS
Box enclosure / DC withstand
String / MPPT topology
Protection / isolation
Outdoor PV DC load-break isolator – 2P, 1500 V, 25 A | Unit: Each
KEY TECHNICAL REQUIREMENTS
Isolation duty
Outdoor suitability
Main LV distribution board (MDB) – 630 A Cu busbar | Unit: Set
KEY TECHNICAL REQUIREMENTS
Voltage / busbar
Assembly compliance
Main / outgoing protection
Hatchery load distribution board – 250 A Cu busbar | Unit: Set
KEY TECHNICAL REQUIREMENTS
Voltage / busbar
Main breaker
Functional outgoing protection
Cold-store distribution panel A – 125 A Cu busbar | Unit: Set
KEY TECHNICAL REQUIREMENTS
Voltage / busbar
Incomer / outgoings
Safety / completion
Auxiliary AC distribution board – 64 A main | Unit: Set
KEY TECHNICAL REQUIREMENTS
Supply / panel
Main / outgoing breakers
Personnel / circuit protection
Main AC inverter / grid distribution switchboard – 63/80 A feeders | Unit: Set
KEY TECHNICAL REQUIREMENTS
Enclosure / electrical system
Incomer / feeders
Electrical protection
Industrial inverter/BMS/EMS communication cable | Unit: m
KEY TECHNICAL REQUIREMENTS
Cable type / protocol
Equipment compatibility
Smart energy manager / inverter coordination package | Unit: Lot
KEY TECHNICAL REQUIREMENTS
Control capability
Metering / communications
Rigid uPVC electrical conduit – Ø50 mm | Unit: m
KEY TECHNICAL REQUIREMENTS
Nominal conduit size
Material / mechanical rating
Flexible metallic liquid-tight electrical conduit – Ø32 mm | Unit: m
KEY TECHNICAL REQUIREMENTS
Nominal conduit size
Ingress / weather resistance
Galvanized cable tray/ladder – 200 mm width | Unit: m
KEY TECHNICAL REQUIREMENTS
Tray size / material
Mechanical construction
Galvanized cable tray/ladder – 300 mm width | Unit: m
KEY TECHNICAL REQUIREMENTS
Tray size / material
Mechanical construction
Underground cable-route markers / warning tape | Unit: m
KEY TECHNICAL REQUIREMENTS
Warning / identification
Outdoor performance
Insulated green/yellow earth bonding conductor – 16 mm² | Unit: m
KEY TECHNICAL REQUIREMENTS
Conductor size / insulation
Conductor material
Complete Site Earthing & Lightning Protection System | Unit: Set
KEY TECHNICAL REQUIREMENTS
Lightning terminals / design
Electrodes / pits / earth bars
Portable ABC fire extinguisher – 5 kg | Unit: Set
KEY TECHNICAL REQUIREMENTS
Fire extinguisher type / capacity
Installation / marking
☐ Yes ☐ No
[insert full name of bidder]
[insert title]
[insert submission date]
[insert signature]
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Lot 1_ Price Schedule (Form D)_Cold Storage Equipment for Additional Energy Component-ITB.xlsx
Bidding document • 0.02 MB
Lot 1_ Technical Bid (Form E)_Cold Storage Equipment for Additional Energy Component-ITB.xlsx
Bidding document • 0.03 MB
Lot 2_ Price Schedule (Form D)_Chicken Hatchery Equipment for Additional Energy Component-ITB.xlsx
Bidding document • 0.01 MB
Lot 2_ Technical Bid (Form E)_Chicken Hatchery Equipment for Additional Energy Component-ITB.xlsx
Bidding document • 0.03 MB
Lot 3_ Price Schedule (Form D)_Electrical Equipment for Additional Energy Component-ITB.xlsx
Bidding document • 0.02 MB
Lot 3_ Technical Bid (Form E)_Electrical Equipment for Additional Energy Component-ITB.xlsx
Bidding document • 0.04 MB
Section II_ Instruction to Bidders ITB65471.pdf
Bidding document • 0.20 MB
Section III_ Evaluation Criteria ITB65471.pdf
Bidding document • 0.07 MB
Section IV_ Schedule of Requirements ITB65471.pdf
Bidding document • 0.21 MB
Section V_ Returnable Bidding Forms.docx
Bidding document • 1.25 MB
Notice on UNGM.html
Notice page • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .