Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Clarification
Dear Bidder, Thank you for your interest in this tender. Question: Dear Sir we would like to clarify the following, 2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa) is this concerte without steel Answer: Item 2.2, "Reinforced concrete grade/class C‑30," is concrete With Steel Reinforcement. However, Reinforcement bars and formwork are measured and paid for separately, as indicated in the Concrete Work pricing notes ."C‑30" refers only to the concrete's strength: a minimum 28‑day compressive strength of 30 MPa on 150 mm cubes. "Reinforced" means the concrete is cast into formwork and vibrated around steel reinforcement bars, as given in the item description.Concrete: Item 2.2 (C‑30 concrete): the rate covers the concrete only. This includes supply of all concrete materials, moisture sealing, placing, vibration, curing, sampling and testing.Formwork: Item 2.3: priced per m².Steel Rebars Item 2.4 (Steel bar reinforcement): Various sizes - priced per kg, by bar diameter, as shown on the structural drawings. The rate includes supply, cutting, bending, placing in position and tying wire.Bidders are reminded to read the BoQ together with the drawings, technical specifications and pricing notes.Best regards,Procurement UnitUNOPS Sudan Office
Clarification
Question: Dear Sir/Madam,We are interested in participating in the tender; therefore, we kindly request you to extend the closing date.Dear Bidder, Thank you for your interest in this tender. Answer: Unfortunately, we are unable to extend the bid submission deadline because of project timelines. The deadline remains unchanged.Best regards,Procurement UnitUNOPS Sudan Office
Clarification
Dear Bidder, Thank you for your interest in this tender. Question: Dear UNOPS Procurement Team,Approach Engineering Co. Ltd. confirms its interest in participating in the above-referenced tender.We kindly request an extension of the bid submission deadline, to allow sufficient time to thoroughly review the tender documents, obtain supplier quotations, and prepare a comprehensive and competitive bid.We would appreciate your consideration and confirmation of the requested extension.Answer: Unfortunately, we are unable to extend the bid submission deadline because of project timelines. The deadline remains unchanged.Best regards,Procurement UnitUNOPS Sudan Office
Amendment #1
Dear Bidders,Thank you to all bidders who participated in the pre-bid meeting.Please note that the tender has been amended to include the Pre-Bid Meeting presentation and Meeting Summary Document, which have been uploaded to the system for reference, particularly for bidders who were unable to attend.Bidders are requested to review the uploaded documents and take them into consideration when preparing their submissions.All the bestProcurement UnitUNOPS Sudan Office.
Tender Value
Refer Docs
Bid Security (EMD)
Refer Docs
Closing Date
26 Nov 2026, 10:00 (UTC)4d left26 Nov 2026, 3:30 pm IST
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender description: Construction of Crops and Vegetables Markets in Kassala Gadaref and Red Sea States, Eastern Sudan. 3 Lots: Lot 1: Construction of Crops and Vegetables Market in Wad Alhiliw, Kassala State. Lot 2: Construction of Crops and Vegetables Market in East Galabat (Doka), Gedaref State. Lot 3: Construction of Crops and Vegetables Market in Tokar, Red Sea Stat. ----- The United Nations Office for Project Services (hereinafter referred to as UNOPS) is pleased to invite competent Bidders/Contractors to submit their respective competitive bids for the Construction of Crops and Vegetables Markets in Kassala Gadaref and Red Sea States, Eastern Sudan (3 Lots) – EFSR Project. in accordance with the UNOPS General Conditions of Contract. ----- IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
321993
ITB/2026/65456
Invitation to bid
Sudan
INVITATION
UTC
21 Nov 2026
10 Nov 2026
United Nations Office for Project Services
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
Tender Reference:
ENHANCING FOOD SECURITY & RESILIENCE OF RURAL COMMUNITIES (EFSR),
CONSTRUCTION WORKS FOR MODEL CROP & VEGETABLE MARKET PROJECT
BILL OF QUANTITIES (BOQ)
- Bill Nr.1 - Mobilization
- Bill Nr.2 to 12-Civil, Electrical & Sanitary Works-BoQ
- Bill Nr.13 - Day Works
NOTE: It is a MANDATORY requirement for bidders to complete and return both this excel BOQs and their respective duly signed pdf for further reference
Failure to complete all sections of the BOQ may result to automatic disqualification of your bid.
September, 2026
PREAMBLE TO BILLS OF QUANTITIES
1 Priliminary Condition
1.1 This Specification shall be read in conjunction with the Particular Technical Specifications provided under each work discipline, as well as the latest edition of the Sudan Standard Technical Specifications for Building Works, or any other internationally recognized standards commonly adopted in Sudan.
1.2 The Bill of Quantities (BoQ) shall be measured in accordance with the latest edition of the Sudan Standard Methods of Measurement for Building Works.Pro Memoria (PM): Indicates that the cost of the item is deemed to be included and distributed within other related work items in the BoQ. No separate payment will be made.Lump Sum (LS): Indicates that the item is priced as a fixed total amount, with no adjustment or variation permitted to the total price regardless of actual quantities executed.
1.3 The contractor has fully understood the scope of works by minutely having studied the drawings and Bill of Quantities with specifications, and by having visited the site. He will, on his own initiative and before the works start and in his best ability, notify the consultant of works which are not mentioned in the BoQ and/or the specifications and/or the drawings, which are necessary to execute the construction as envisioned in the drawings. Thus, after the works have started, the contractor cannot rely on incompletions in the consultants' work to make claims of any kind. Indeed, the contractor will add upon the specifications according to his own insight and professional experience. If there are works to be done which are not specified in this BoQ, it is up to the consultant to decide wether these works are variation works which need change orders, or wether these works are included in the items and their prices in the BoQ.
1.4 The contractor has to execute all works which have a direct or indirect impact on safety and availability of infrastructure (water, sewage, electricity, …) in as short a period as feasible.
1.5 The contractor will secure the structural and functional integrity of the exsiting buildings nearby the project site during construction work as well as of the building’s surroundings such as but not limited to public road, gate, lawn. He will study and execute the necessary scaffolding to support the building, in order to avoid any cracks, settlements, or crumbling. This scaffolding to support the building during the works are included in the prices given. Debris will be cart away to certified debris places in the area. In no way, debris will be stored, buried or burned on site.
1.6 After the works, the contractor will do a thorough cleaning of the construction site, this means cleaning of all excess mortars, cement bags, excess blockwork, excess tile jointing – in short any construction remnant which hinders the proper use of the house upon site hand-over.
1.7 In general the contractor will put his professional experience and craftsmanship to work, in order to get a holistically well-constructed building, to the highest and most up-to-date standards of Sudan Construction Culture.
2 Organisation of Construction Site
This includes all necessary preparations to execute the works; at least from the beginning until the end of the works; according to the best knowledge and experience of the contractor: at least conform local standards.
The objectives of the Bill of Quantities are
(a) to provide sufficient information on the quantities of Works to be performed to enable bids to be prepared efficiently and accurately; and
(b) when a Contract has been entered into, to provide a priced Bill of Quantities for use in the periodic valuation of Works executed.
In order to attain these objectives, Works have been itemized in the Bill of Quantities in sufficient detail to distinguish between the different classes of Works, or between Works of the same nature carried out in differently or in other circumstances which may give rise to different considerations of cost.
4 The Bills of Quantities for the Works comprise the following:
Preamble to Bill of Quantities
List of principal Quantities
Bill Nr. 1 Mobilization
Bill Nr. 2 - 12 Civil, Electrical Installation & Sanitary Installation
Bill Nr. 13 Day Works
5 The Contractor’s unit rates in these bills are to cover supplying of materials, taking delivery, transporting, loading and off loading inspection, storage, stacking, landing, preparation, installation including provision of all labour, requirement false work, temporary support, surface preparation and testing of the works. The rates shall include all applicable taxes and duty. The cost of testing of the materials to be used in the works unless otherwise provided is to be included in the rates of the respective Bill items.
6 Measurement for payment shall be for the complete installation and having passed all necessary tests.
7 Work shall not be executed on a Day work basis unless ordered in writing by the Consultant on approval by the Employer. The rates entered in the Day works Bill of Quantities shall apply to any quantity of Day work instructed by the Consultant. Nominal quantities have been indicated against each item to permit the extended total to be carried forward to the Grand Summary.
8 “Rates and prices shall be inserted in the rate and total columns of the Bill of Quantities in USD
9 Bills of Quantities are to be read in conjunction with the Instructions to Bidders, the Conditions of Contract Data, the Specifications and the Drawings. The quantities stated against each item in the Bills of Quantities, with the exception of those items specifically marked ‘sum’, are the estimated quantities of the Work to be executed by the Contractor in fulfillment of his obligations under the Contract.
10 The Contractor is required to check the number of the pages and should any be found to be missing or in duplicate he must inform the Engineer at once and have the same rectified.
11 No liability whatever will be admitted or claim allowed in respect of errors in the Contractor’s tender due to mistakes in the Bills of Quantities which should have been rectified in the manner described above.
12 The contractor shall not alter or otherwise qualify the text of these Bills of Quantities. Any alteration or qualification made without authority will be ignored and the text of the Bills of Quantities as printed will be adhered to.
13 Each item in the Bills of Quantities is to be priced. If any items are left un-priced it will be assumed that the value of the work described there under is elsewhere allowed for. The prices and rates to be inserted in the Bills of Quantities are to be fully inclusive of all costs and expenses which may be required for the construction of the work described, together with general risks, liabilities and obligations set forth or implied in these documents.
14 In no case will any claim for expenses incurred by the Contractor in preparation of this Tender be allowed.
15 The Contractor is solely responsible for the accurate ordering of materials in accordance with the Specifications, Drawings and Engineer’s Instructions and no claim for any loss or expense will be entertained for orders for materials based on the Bills of Quantities.
16 The quantities given in the Bills of Quantities are estimated and no claim by the Contractor for the final quantities being larger or smaller than the quantities given in the Bills of Quantities will be permitted except alows in accordance with the particular of the Conditions of Contract.
17 The term ‘provide’ or ‘supply’ used for any item shall be deemed to include transport to site, handling, storage and fixing complete, and the Bidder’s rate shall include for this.
18 The following abbreviations have been used in the Bills of Quantities:-
ml metre linear
m2 square metre
PS provisional Sum
Set Complete set of work with accessories & components
lot Complete set of work with accessories & components
PS provisional Sum
USD United States Dollar
uPVC un-plasticized poly vinyl chloride
HDPE high density polyethylene
GMS galvanized mild steel
PPE personal protective equipment
ASTM American society for testing & material
GW well-graded gravel
GP poorly-graded gravel
GM silty gravel, gravel-sand-silt mixtures
GC Clayey gravels, gravel sand-clay mixtures
SW well graded sands
SP poorly graded sands
SM silty sand, sand -silt-mixtures
SC clayey sands, sand-clay mixtures
AASHO American Association of State Highway and Transportation Officials,
ACI American Concrete Institue
RHS rectangular hollow section
PVD Physical Vapor Deposition
HCB hollow concret block
CBR california bearing ratio
MC medium curing
SDB sub distribution board
PDB pump distrbution board
20 Unless otherwise provided there are no separate measurement items for Contractual requirements. The Contractor is deemed to have included his costs for the Contractual requirement
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILIENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
ALL BILLS SUMMARY Amount in USD
1 Bill Nr.1 - Mobilization USD 0.00
2 Bill Nr.2 -Crop Market Building-
2.1 - Civil Work USD 0.00
2.2 - Electrical Installation Work USD 0.00
3 Bill Nr.3 -Vegetable Market Building-
3.1 - Civil Work USD 0.00
3.2 - Electrical Installation Work USD 0.00
3.3 - Crop & Vegetable Sanitary Installation Work USD 0.00
4 Bill Nr.4 -Multi-Purpose Hall Building-
4.1 - Civil Work USD 0.00
4.2 - Electrical Installation Work USD 0.00
4.3 - Sanitary Installation Work USD 0.00
5 Bill Nr.5 -Security/Guard House Building-
5.1 - Civil Work- For Two (2) Unit USD 0.00
5.2 - Electrical Installation Work- For Two (2) Unit USD 0.00
5.3 - Sanitary Installation Work- For Two (2) Unit USD 0.00
6 Bill Nr.6 -Toilet Building With Pit Laterin-
6.1 - Civil Work-Fot Two (2) Unit USD 0.00
6.2 - Electrical Installation Work-Fot Two (2) Unit USD 0.00
6.3 - Sanitary Installation Work-Fot Two (2) Unit USD 0.00
7 Bill Nr.7 Pump Control Swith Shed with Water Tanker Seat
7.1 - Civil Work for Two (2) Unit USD 0.00
7.2.1 - Electrical Installation Work Pump House-1 USD 0.00
7.2.2 - Electrical Installation Work Pump House-2 USD 0.00
8 Bill Nr.8 Solid Waste Collection-Civil Work USD 0.00
9 Bill Nr.9 Site Works-Civil USD 0.00
10 Bill Nr.10 Site Work-Electrical USD 0.00
11 Bill Nr.11-Site Works-Sanitary USD 0.00
12 Bill Nr.12 Signage USD 0.00
GRAND TOTAL USD 0.00
13 Bill Nr.13 - Day Works USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILIENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill Nr. 1- Mobilization
1 SIGN BOARD USD 0.00
2 SITE SUPERVISOR TRANSPORTATION USD 0.00
3 SAFTEY HARNESS & PROTECTION USD 0.00
4 SAFTEY & SECURITY OF WORKS USD 0.00
5 SHOP DRAWINGS USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 Contractor to provide a Project Identification sign size (200 cm × 200 cm), Contractor to submit shop drawing for UNOPS Engineer Approval, also 2 safety signs (120 cm x 120 cm). Safety signed to be submitted to approval of Engineers. LS 1.00 0.00
2 Site Supervisor Office & Transportation
2.1 Providing office for supervisor team completed with office Desk LS 1.00 0.00
3 Safety Harness and Protection
3.1 2 No (Minimum) Safety Harness with lanyards , 3 fire powder 6Kg fire extinguishers, and selection of gloves & safety glasses to be kept in UNOPS Office at all time, also contractor should in his price include the cost of providing all his staff and work force with suitable PPEs ( i.e. Hard Hat, Safety Boot, Dust Masks, Safety Vests and Safety Glasses) LS 1.00 0.00
4 Safety & Security of Works
4.1 Allow for providing safety and security for the Works and material as per the requirement laid under the Contract, including security lighting, lockable or open material storage areas, engaging security guards and / or any other measures as necessary. Cost shall include Road Safety awareness, and public traffic flow management during construction. In case the project intervention is inside the existing operational compound and accordingly the contractor shall make all the necessary planning on Contractor Safety, Security, and Operational Continuity Protocol ensures that construction works are performed without disrupting the existing business normal operations or compromising its safety and security. Contractors must strictly adhere to all guidelines, ensuring seamless coordination with the existing business management team & the consultant. Non-compliance may considered as a breach of the Contract. Contractor shall construct temporary fencing that separate the existing business and the construction site, safety access route and separate access. The contractor shall also indicated his methodology and work plan for the specific topics. LS 1.00 0.00
5 Shop Drawings
5.1 Allow for prepare and submit to the Engineer's Representative a complete set of Shop Drawings, as required to the specified scale(s), giving all details, as required by the Engineer's Representative, for the work executed. Submission shall be in 3 sets as hard copies, color printed on A1 size paper and 01 set of soft copies in AutoCAD compatible version in a compact disc. LS 1.00 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILIENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.1- Crop Market Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 1,706.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 853.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 685.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 251.00 0.00
1.5 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 89.00 0.00
1.6 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 1,272.00 0.00
1.7 Ditto as above item 1.5 but around isolated footing. m3 764.00 0.00
1.8 Ditto as above item 1.5 but around masonry foundation wall. m3 34.00 0.00
1.9 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 1,876.00 0.00
1.10 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 1,203.00 0.00
1.11 Supply and fix construction joint between grade beam & grade slab with 1 cm thick x 15cm wide chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance. ml 786.00 0.00
1.12 Ditto as above item 1.10 but construction joint between grade slab & grade slab where the slab area is larger. ml 125.00 0.00
1.13 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 340.00 0.00
2.1.2 Under masonry foundation wall m2 89.00 0.00
2.1.3 Under grade beam m2 109.00 0.00
2.1.4 Under slab on grade including ramp m2 1,203.00 0.00
2.1.5 Under masonry steps on grade m2 26.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 140.20 0.00
2.2.2 In foundation column. m3 26.00 0.00
2.2.3 In grade beams. m3 50.00 0.00
2.2.4 In ramp restrain beams. m3 1.20 0.00
2.2.5 In entrance steps. m3 6.20 0.00
2.2.6 In 15 cm thick ground floor slab including ramps & half part of open market. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing. m2 1,202.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 207.00 0.00
2.3.2 To foundation column m2 273.00 0.00
2.3.3 To grade beams & ramps edge m2 378.00 0.00
2.3.4 To ramp restrain beam m2 12.00 0.00
2.3.5 To entrance steps m2 80.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 8 mm deformed bar Kg 149.00 0.00
Dia 12 mm deformed bar Kg 2,577.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 1,208.00 0.00
Dia 16 mm deformed bar Kg 2,310.00 0.00
Dia 20 mm deformed bar Kg 2,269.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 1,665.00 0.00
Dia 16 mm deformed bar Kg 4,931.00 0.00
2.4.4 For ramp restrain beam
Dia 8 mm deformed bar Kg 37.00 0.00
Dia 12 mm deformed bar Kg 71.00 0.00
2.4.5 For entrance steps
Dia 8 mm deformed bar Kg 448.00 0.00
Dia 16 mm deformed bar Kg 208.00 0.00
2.4.6 For floor slab on grade, ramp slab & outdoor tratment slab
Dia 8 mm deformed bar Kg 377.00 0.00
Dia 10 mm deformed bar Kg 9,520.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 92.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 26.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 29.10 0.00
1.1.2 In intermidiate beams m3 32.50 0.00
1.1.3 In top tie beams m3 13.60 0.00
1.1.4 In internal partition wall tie beams m3 3.27 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 263.00 0.00
1.2.2 To intermidiate beams m2 314.00 0.00
1.2.3 To top tie beams m2 127.00 0.00
1.2.4 In internal partition wall tie beams m2 32.70 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 1,392.00 0.00
Dia 16 mm deformed bar Kg 636.00 0.00
Dia 20 mm deformed bar Kg 2,540.00 0.00
1.3.2 For intermidiate beam
Dia 8 mm deformed bar Kg 1,048.00 0.00
Dia 16 mm deformed bar Kg 3,281.00 0.00
1.3.3 For top tie beam
Dia 8 mm deformed bar Kg 483.00 0.00
Dia 16 mm deformed bar Kg 1,507.00 0.00
1.3.4 For tinternal partiton tie beam
Dia 8 mm deformed bar Kg 150.69 0.00
Dia 12 mm deformed bar Kg 290.38 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick. The bricks shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct both-side decorative face red burnt 20cm thick (double) brick wall, built in approved red burnt clay face bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, with exposed face brick finish on both sides complete in every respect m2 587.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 908.00 0.00
3.2 Ditto as above item 3.1 but gable side pre-painted 0.5mm thick EGA-500 wall clad fixed to RHS frame as shown in the structural drawing. m2 68.00 0.00
3.3 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet ridge cup at the roof slope direction changes. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of ridge cap: 80 cm. m.l. 32.00 0.00
3.4 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 126.00 0.00
3.5 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 63.00 0.00
Total carried to summary USD 0.00
4.1 Supply, fabricate and fix metal guard rail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 120 × 120 × 6 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 1000 mm above finished floor level; two horizontal balustrade rails CHS Ø20 × 2.5 mm welded to vertical RHS posts; top handrail CHS Ø50 × 2.5 mm welded continuously; infill: vertically spaced CHS Ø20 × 2.5 mm at c/c 100 mm between the two horizontal rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 99.50 0.00
4.2 Supply, fabricate and fix metal ramp & step handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 38.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect Pre-Engineerered structures steel as primary and secondary members & all other reuired accessories.The material standard and fabrication be according to applicable American, British or Europian codes and standards. The material shall be as per approved pre-engineered building sysem standard and shall include column, rafter & truss (Hot rolled and built up I-sections), purlin (Rectangular hollow section), Bracings (rod Bracings), Screws, high strength bolts, Machine Bolts,Anchor bolts, Plates and other accessories.
The system is designed for Corrosively Category C3 and Long Design Life (15+ years) in accordance with ISO 12944. Prefabrication Primer Apply one coat of zinc-rich epoxy primer to a dry film thickness (DFT) of 20-25 µm. shop Coating: After fabrication, clean welds and bolt holes and apply full epoxy intermediate coat to achieve a minimum total shop DFT of 75 µm
All structural steel members shall be protected with an approved, certificated; thin-film intumescent coating system to achieve a fire resistance rating of R60. The required Dry Film Thickness (DFT) for the minimum intumescent coating shall be 1200 µm
All damage to shop coatings incurred during transport and erection shall be cleaned and repaired to the original specification. After erection, apply a final coat of an approved Polyurethane (PU) Topcoat. The total system DFT for the full corrosion protection system (primer, intermediate and topcoat) shall be a minimum of 285 µm over the entire structure.
All are as per the detail structural drawing and specification.
A. Primary Structure
A.1 Supply, fabricate, deliver, and erect IPE 400 steel column , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 400mm, flage width 180mm, web thickness 8.60mm, flange thickness 13.50mm & unit weight kg/ml 66.30kg/ml kg 915.00 0.00
A.2 Supply, fabricate, deliver, and erect IPE 400 rafter , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 400mm, flage width 180mm, web thickness 8.60mm, flange thickness 13.50mm & unit weight kg/ml 66.30kg/ml kg 11,537.00 0.00
A.3 Supply, fabricate, deliver, and erect IPE 100 canopy truss , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 100mm, flage width 55mm, web thickness 4.10mm, flange thickness 5.70mm & unit weight kg/ml 8.10kg/ml kg 671.00 0.00
B. Secondary Structure
B.3 Supply, fabricate, deliver, and erect IPE 300 secondary beam , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 300mm, flage width 150mm, web thickness 7.10mm, flange thickness 10.50mm & unit weight kg/ml 42.20kg/ml kg 2,532.00 0.00
C. RHS Purlins 0.00
C.1 RHS 100 x 100 x 4mm purlin fixed to upper truss member with 100 x 100 x 3mm L= 60mm angle iron. Price include angle iron. Kg 12,913.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
D. RHS Gable side frame 0.00
D.1 RHS 30 x 30 x 3mm RHS frame for gable side EGA wall clad support Kg 387.00 0.00
A.1 IPE 400 column & concrete colomn connection plate size 560 x 360 x 20mm with 8 dia 22mm sloted holes. No 24.00 0.00
A.2 IPE 400 column & rafter connection plate size 180 x 822 x 10mm with 12 dia 18mm sloted holes. No 24.00 0.00
A.3 IPE 400 column & IPE 300 secondary beam connection plate size 200 x 155 x 10mm with 4 dia 18mm sloted holes. No 40.00 0.00
A.4 IPE 400 rafter & rafter connection plate at Apex size 180 x 844 x 10mm with 4 dia 18mm sloted holes. No 12.00 0.00
A.5 IPE 100 truss & concete wall mounted connection plate size 300 x 280 x 10mm with 8 M20 bolt sloted holes. No 48.00 0.00
A.6 Stiffner size 180-80 x 10mm No 48.00 0.00
B Bolt with nut
B.1 Anchor bolt with nut column connection with concrete column M20 grade 8.8 depth 300mm No 96.00 0.00
B.2 Anchor bolt with nut canopy truss with concrete column M20 grade 8.8 depth 450mm No 192.00 0.00
B.3 Bolt with nut for column with rafter connection M 16 grade 8.8 No 144.00 0.00
B.4 Bolt with nut for column with secondary beam connection M 16 grade 8.8 No 80.00 0.00
B.5 Bolt with nut for rafter with rafter at Apex connection M 16 grade 8.8 No 72.00 0.00
B.6 C1022 hex head Tek screw fixed to concrete beam No 56.00 0.00
C Tension Cable
Supply, fabricate and install tension cable bracing system for steel roof trusses, comprising T32 mm threaded tension rods/cables, turnbuckles, coupling nuts, paddle braces, gusset plates, suspension plates, clevises, anchor connections, bolts, nuts, washers and all necessary fittings, complete with tensioning, alignment and fixing in accordance with the structural drawing, approved shop drawings and Engineer's instructions. Ml 214.40 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply three coats of cement sand plaster (1:3) for exposed beam and column surfaces.The final coat shall be made with fine sand sieved through a 1.18 mm mesh. surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks m2 704.00 0.00
6.2 Rake out joints where required and execute pointing to stone masonry joint work using cement-sand mortar of specified mix, including cleaning joints, wetting surfaces, filling, finishing, curing, and all necessary labor, materials, tools, and incidentals, complete in accordance with the drawings and specifications. m2 52.00 0.00
6.3 Rake out joints where required and execute pointing to decorative red brick joint work using cement-sand mortar of specified mix, including cleaning joints, wetting surfaces, filling, finishing, curing, and all necessary labor, materials, tools, and incidentals, complete in accordance with the drawings and specifications. m2 1,174.00 0.00
6.4 Provide and lay 50 mm thick cement-sand screed flooring, finished with a smooth steel-trowelled surface, using cement and clean sand mixed in the specified proportion (1:3 or as specified), laid to the required levels, slopes, and falls, including surface preparation, mixing, placing, compacting, leveling, finishing, curing, and all labor, materials, tools, equipment, and incidentals necessary to complete the work in accordance with the drawings and specifications- for crop storage area. m2 444.00 0.00
6.5 Provide broom finish to freshly placed concrete carway, Pavmeny & ramp surface, including screeding, leveling, texturing the surface with a broom to produce a uniform non-slip finish, and all labor, tools, equipment, and incidentals necessary to complete the work in accordance with the specifications and Engineer's instructions. Concrete work measured separately. m2 878.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
7.1 Apply three coats of acrylic emulsion paint to exposed beam & column plastered wall surfaces. m2 704.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.2- Crop Market Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ELECTRICAL WORKS
1.1 DISTRIBUTION BOARDS 0.00
Flush-mounted sub distribution Board, SDB-CM in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1.1.1 1pc main MCB of 32A, 4P , Icu=10KA , coupled with RCD ,300mA, Type S/ Time delayed 0.00
10pcs RCBO of 16A, 2P, Icu=6KA ,30mA 0.00
6pcs MCB of 10A, 2P, Icu=6KA
2pcs MCB of 16A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A, 3ph+N No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 44.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W,4000K, 3600Lumen, CRI > 80, ceiling-mounted, polycarbonate, flicker-free, IP66, for outdoor instalation No 8.00 0.00
1.3.L2E LED battenLight: L1200mm, 30W, 3600 lumens, 4000K, CRI > 80, surface-mounted.High-impact polycarbonate housing and diffuser with minimum IP65 protection rating , & ~1000 lumens (emergency), 4000K, 90 minute operation, No 4.00 0.00
1.3.L4 LED Highbay , pendant ( truss mounted), D273,h 93mm, 100w, 13000Lumens, 6500K, CRI>80. Die-cast aluminum housing with a clear optical polycarbonate lens (IP65 / IK06 rated) and a 100° to 110° wide beam angle. Complete with integrated driver, suspension mounting hook/accessories, and hardware. No 20.00 0.00
1.3.(E) Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). IP65,IK08, 5700K, minimum 7W, autonomy 90min. Warranty: 3 years (components), 5 years (battery). No 8.00 0.00
1.3.(EX) Saftey only emergency with FLC 11SE or approved equivallent illuminated signage system shall be installed to give information with standard dimensions information displays and illumination level with double or single faces. The display consisting of symbols, text or figures supported with direction which will indicate EXIT, toilets (lady and gentlemen), staircases and floor level will be placed as indicated on the drawings throughout building for the convenience of the public and workers .The symbols, text or figures shall be choices of the client or engineer and shall be appropriate enough to describe the room, areas, services and all safety directions it should have emergency battery for at least 90min. No 4.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Flush-mounted thumbler switch in sheet steel enclosure with lockable door with 6pcs of 16A/1Ph two way tumbler switchs including all necessary fixing and connecting accessories No 2.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 30.00 0.00
1.6 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.6.1 16A ,1ph ,230V 2p+e Doublesocket outlet No 18.00 0.00
1.6.2 16A ,2P,230V 2p+e Doublesocket out let water proof for outdoor installation IP44. No 12.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.3.1- Vegetable Market Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 1,706.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 853.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 615.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 226.00 0.00
1.4 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 87.00 0.00
1.5 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 1,274.00 0.00
1.6 Ditto as above item 1.5 but around isolated footing. m3 680.00 0.00
1.7 Ditto as above item 1.5 but around masonry foundation wall. m3 33.00 0.00
1.8 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 1,895.00 0.00
1.9 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 1,213.00 0.00
1.10 Supply and fix construction joint between grade beam & grade slab with 1 cm thick x 15cm wide chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance. ml 645.00 0.00
1.11 Ditto as above item 1.10 but construction joint between grade slab & grade slab where the slab area is larger. ml 210.00 0.00
1.12 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 308.00 0.00
2.1.2 Under masonry foundation wall m2 79.00 0.00
2.1.3 Under grade beam m2 76.00 0.00
2.1.4 Under slab on grade including ramp m2 1,213.00 0.00
2.1.5 Under masonry steps on grade m2 26.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 132.00 0.00
2.2.2 In foundation column. m3 23.00 0.00
2.2.3 In grade beams. m3 40.00 0.00
2.2.4 In ramp restrain beams. m3 1.20 0.00
2.2.5 In entrance steps. m3 6.20 0.00
2.2.6 In 15 cm thick ground floor slab including ramps & half part of open market. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 1,213.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 187.00 0.00
2.3.2 To foundation column m2 236.00 0.00
2.3.3 To grade beams & ramps edge m2 296.00 0.00
2.3.4 To ramp restrain beam m2 12.00 0.00
2.3.5 To entrance steps m2 80.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 8 mm deformed bar Kg 124.00 0.00
Dia 12 mm deformed bar Kg 2,181.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 1,084.00 0.00
Dia 16 mm deformed bar Kg 1,770.00 0.00
Dia 20 mm deformed bar Kg 2,269.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 1,286.00 0.00
Dia 16 mm deformed bar Kg 3,783.00 0.00
2.4.4 For ramp restrain beam
Dia 8 mm deformed bar Kg 37.00 0.00
Dia 12 mm deformed bar Kg 71.00 0.00
2.4.5 For entrance steps
Dia 8 mm deformed bar Kg 448.00 0.00
Dia 16 mm deformed bar Kg 208.00 0.00
2.4.6 For floor slab on grade, ramp slab & outdoor tratment slab
Dia 8 mm deformed bar Kg 377.00 0.00
Dia 10 mm deformed bar Kg 9,488.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 87.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 26.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 29.10 0.00
1.1.2 In intermidiate beams m3 32.50 0.00
1.1.3 In top tie beams m3 13.60 0.00
1.1.4 In internal partition wall tie beams m3 2.16 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 232.00 0.00
1.2.2 To intermidiate beams m2 217.00 0.00
1.2.3 To top tie beams m2 127.00 0.00
1.2.4 In internal partition wall tie beams m2 21.60 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 1,288.00 0.00
Dia 16 mm deformed bar Kg 318.00 0.00
Dia 20 mm deformed bar Kg 2,540.00 0.00
1.3.2 For intermidiate beam
Dia 8 mm deformed bar Kg 693.00 0.00
Dia 16 mm deformed bar Kg 2,186.00 0.00
1.3.3 For top tie beam
Dia 8 mm deformed bar Kg 483.00 0.00
Dia 16 mm deformed bar Kg 1,507.00 0.00
1.3.4 For tinternal partiton tie beam
Dia 8 mm deformed bar Kg 99.54 0.00
Dia 12 mm deformed bar Kg 191.81 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct both-side decorative face red burnt 20cm thick (double) brick wall, built in approved red burnt clay face bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, with exposed face brick finish on both sides complete in every respect m2 677.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 909.00 0.00
3.2 Ditto as above item 3.1 but gable side pre-painted 0.5mm thick EGA-500 wall clad fixed to RHS frame as shown in the structural drawing. m2 68.00 0.00
3.3 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet ridge cup at the roof slope direction changes. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of ridge cap: 80 cm. m.l. 32.00 0.00
3.4 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 126.00 0.00
3.5 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 63.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors all as per the drawing. Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint.
D2 size 170cm x 260cm no 12.00 0.00
4.2 Supply, fabricate and fix metal guard rail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 120 × 120 × 6 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 1000 mm above finished floor level; two horizontal balustrade rails CHS Ø20 × 2.5 mm welded to vertical RHS posts; top handrail CHS Ø50 × 2.5 mm welded continuously; infill: vertically spaced CHS Ø20 × 2.5 mm at c/c 100 mm between the two horizontal rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 99.50 0.00
4.3 Supply, fabricate and fix metal ramp & step handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 38.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect Pre-Engineerered structures steel as primary and secondary members & all other reuired accessories.The material standard and fabrication be according to applicable American, British or Europian codes and standards. The material shall be as per approved pre-engineered building sysem standard and shall include column, rafter & truss (Hot rolled and built up I-sections), purlin (Rectangular hollow section), Bracings (rod Bracings), Screws, high strength bolts, Machine Bolts,Anchor bolts, Plates and other accessories.
The system is designed for Corrosively Category C3 and Long Design Life (15+ years) in accordance with ISO 12944. Prefabrication Primer Apply one coat of zinc-rich epoxy primer to a dry film thickness (DFT) of 20-25 µm. shop Coating: After fabrication, clean welds and bolt holes and apply full epoxy intermediate coat to achieve a minimum total shop DFT of 75 µm
All structural steel members shall be protected with an approved, certificated; thin-film intumescent coating system to achieve a fire resistance rating of R60. The required Dry Film Thickness (DFT) for the minimum intumescent coating shall be 1200 µm
All damage to shop coatings incurred during transport and erection shall be cleaned and repaired to the original specification. After erection, apply a final coat of an approved Polyurethane (PU) Topcoat. The total system DFT for the full corrosion protection system (primer, intermediate and topcoat) shall be a minimum of 285 µm over the entire structure.
All are as per the detail structural drawing and specification.
A. Primary Structure
A.1 Supply, fabricate, deliver, and erect IPE 400 steel column , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 400mm, flage width 180mm, web thickness 8.60mm, flange thickness 13.50mm & unit weight kg/ml 66.30kg/ml kg 915.00 0.00
A.2 Supply, fabricate, deliver, and erect IPE 400 rafter , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 400mm, flage width 180mm, web thickness 8.60mm, flange thickness 13.50mm & unit weight kg/ml 66.30kg/ml kg 11,537.00 0.00
A.3 Supply, fabricate, deliver, and erect IPE 100 canopy truss , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 100mm, flage width 55mm, web thickness 4.10mm, flange thickness 5.70mm & unit weight kg/ml 8.10kg/ml kg 671.00 0.00
B. Secondary Structure
B.3 Supply, fabricate, deliver, and erect IPE 300 secondary beam , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 300mm, flage width 150mm, web thickness 7.10mm, flange thickness 10.50mm & unit weight kg/ml 42.20kg/ml kg 2,532.00 0.00
C. RHS Purlins 0.00
C.1 RHS 100 x 100 x 4mm purlin fixed to upper truss member with 100 x 100 x 3mm L= 60mm angle iron. Price include angle iron. Kg 12,913.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
D. RHS Gable side frame 0.00
D.1 RHS 30 x 30 x 3mm RHS frame for gable side EGA wall clad support Kg 387.00 0.00
A.1 IPE 400 column & concrete colomn connection plate size 560 x 360 x 20mm with 8 dia 22mm sloted holes. No 24.00 0.00
A.2 IPE 400 column & rafter connection plate size 180 x 822 x 10mm with 12 dia 18mm sloted holes. No 24.00 0.00
A.3 IPE 400 column & IPE 300 secondary beam connection plate size 200 x 155 x 10mm with 4 dia 18mm sloted holes. No 40.00 0.00
A.4 IPE 400 rafter & rafter connection plate at Apex size 180 x 844 x 10mm with 4 dia 18mm sloted holes. No 12.00 0.00
A.5 IPE 100 truss & concete wall mounted connection plate size 200 x 200 x 10mm with 4 dia 14mm sloted holes. No 48.00 0.00
A.6 Stiffner size 180-80 x 10mm No 48.00 0.00
B Bolt with nut
B.1 Anchor bolt with nut column connection with concrete column M20 grade 8.8 depth 300mm No 96.00 0.00
B.2 Anchor bolt with nut canopy truss with concrete column M20 grade 8.8 depth 450mm No 192.00 0.00
B.3 Bolt with nut for column with rafter connection M 16 grade 8.8 No 144.00 0.00
B.4 Bolt with nut for column with secondary beam connection M 16 grade 8.8 No 80.00 0.00
B.5 Bolt with nut for rafter with rafter at Apex connection M 16 grade 8.8 No 72.00 0.00
B.6 C1022 hex head Tek screw fixed to concrete beam No 56.00 0.00
C Tension Cable
Supply, fabricate and install tension cable bracing system for steel roof trusses, comprising T32 mm threaded tension rods/cables, turnbuckles, coupling nuts, paddle braces, gusset plates, suspension plates, clevises, anchor connections, bolts, nuts, washers and all necessary fittings, complete with tensioning, alignment and fixing in accordance with the structural drawing, approved shop drawings and Engineer's instructions. Ml 214.40 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply three coats of cement sand plaster (1:3) for exposed beam and column surfaces.The final coat shall be made with fine sand sieved through a 1.18 mm mesh. surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks m2 576.00 0.00
6.2 Rake out joints where required and execute pointing to stone masonry joint work using cement-sand mortar of specified mix, including cleaning joints, wetting surfaces, filling, finishing, curing, and all necessary labor, materials, tools, and incidentals, complete in accordance with the drawings and specifications. m2 51.00 0.00
6.3 Rake out joints where required and execute pointing to decorative red brick joint work using cement-sand mortar of specified mix, including cleaning joints, wetting surfaces, filling, finishing, curing, and all necessary labor, materials, tools, and incidentals, complete in accordance with the drawings and specifications. m2 1,354.00 0.00
6.4 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect.for vegitable market. m2 299.00 0.00
6.5 10cm high 1cm thick chamfered ceramic skirting of matching color to floor tiles. ml 82.00 0.00
6.6 Provide and lay 50 mm thick cement-sand screed flooring, finished with a smooth steel-trowelled surface, using cement and clean sand mixed in the specified proportion (1:3 or as specified), laid to the required levels, slopes, and falls, including surface preparation, mixing, placing, compacting, leveling, finishing, curing, and all labor, materials, tools, equipment, and incidentals necessary to complete the work in accordance with the drawings and specifications for vegitable store m2 138.00 0.00
6.7 Provide broom finish to freshly placed concrete carway, Pavmeny & ramp surface, including screeding, leveling, texturing the surface with a broom to produce a uniform non-slip finish, and all labor, tools, equipment, and incidentals necessary to complete the work in accordance with the specifications and Engineer's instructions. Concrete work measured separately. m2 917.00 0.00
6.8 Supply and fix concrete copping for short wall . Price shall include cement sand mortar bed and cement grouting. ml 70.00 0.00
6.9 Construct Vegetable Display Raised Suspended Floor – comprising raised display platform formed with 50mm thick precast reinforced concrete slabs (1000 × 1200mm), supported on 100mm thick concrete block piers/walls at spacing and arrangement shown on the drawings; including under-display storage space complete with LTZ frame and 30 × 38mm steel louvered doors; 300 × 300 × 8.5mm ceramic floor/wall tiles fixed to the precast concrete top surface including adhesive, grout and all necessary cutting; complete with reinforcement, concrete block supports, fixing accessories, finishing, cleaning, and all incidental works necessary for a complete installation in accordance with the drawings and specifications. One unit covers 37.45m2 and we have 4 unit in total. Ls 1.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
7.1 Apply three coats of acrylic emulsion paint to exposed beam & column plastered wall surfaces. m2 576.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.3.2- Vegetable Market Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ELECTRICAL WORKS
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Flush-mounted sub distribution Board, SDB-VM in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 40A, 4P , Icu=10KA, coupled with RCD ,300mA Type S/ Time delayed 0.00
18pcs RCBO of 16A, 2P, Icu=6KA ,30mA 0.00
6pcs MCB of 10A, 2P, Icu=6KA
2pcs MCB of 16A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A, 3ph+N No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 44.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W,4000K, 3600Lumen, CRI > 80, ceiling-mounted, polycarbonate, flicker-free, IP66, for outdoor instalation No 9.00 0.00
1.3.L2E LED battenLight: L1200mm, 30W, 3600 lumens, 4000K, CRI > 80, surface-mounted.High-impact polycarbonate housing and diffuser with minimum IP65 protection rating , & ~1000 lumens (emergency), 4000K, 90 minute operation, No 3.00 0.00
1.3.L4 LED Highbay , pendant ( truss mounted), D273,h 93mm, 100w, 13000Lumens, 6500K, CRI>80. Die-cast aluminum housing with a clear optical polycarbonate lens (IP65 / IK06 rated) and a 100° to 110° wide beam angle. Complete with integrated driver, suspension mounting hook/accessories, and hardware. No 20.00 0.00
1.3.(E) Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). IP65,IK08, 5700K, minimum 7W, autonomy 90min. Warranty: 3 years (components), 5 years (battery). No 8.00 0.00
1.3.(EX) Saftey only emergency with FLC 11SE or approved equivallent illuminated signage system shall be installed to give information with standard dimensions information displays and illumination level with double or single faces. The display consisting of symbols, text or figures supported with direction which will indicate EXIT, toilets (lady and gentlemen), staircases and floor level will be placed as indicated on the drawings throughout building for the convenience of the public and workers .The symbols, text or figures shall be choices of the client or engineer and shall be appropriate enough to describe the room, areas, services and all safety directions it should have emergency battery for at least 2 hours . No 4.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Flush-mounted thumbler switch in sheet steel enclosure with lockable door with 6pcs of 16A/1Ph two way tumbler switchs including all necessary fixing and connecting accessories No 2.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 44.00 0.00
1.6 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.6.1 16A ,2P,230V 2p+e Doublesocket out let No 32.00 0.00
1.6.2 16A ,2P,230V 2p+e Doublesocket out let water proof for outdoor installation IP44. No 12.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.3.3- Crop & Vegetable Market Building-Sanitary
1 ROOF RAIN WATER DOWN PIPING SYSTEM USD 0.00
2 FIR FIGHTING SYSTEM USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ROOF RAIN WATER DOWN PIPING SYSTEM
1.1 Rainwater Downpipe DN 100 (Market Block) – Supply, install, test, and commission one uPVC rainwater downpipe, DN 100 mm nominal diameter, conforming to ISO 1452-1 or AS/NZS 1260, minimum wall thickness 2.5 mm. Include stainless steel leaf guard (5 mm mesh) at roof inlet, galvanized pipe brackets (vertical spacing 1.8 m maximum, horizontal spacing 1.0 m maximum), UV-reflective light-colored oil paint coating (white/light grey) conforming to ISO 4892-2 on all exposed sections, and discharge splash block at base. Complete from roof outlet to ditch/splash block. ml 290.00 0.00
1.2 Horizontal extension (sprout) from roof downpipe – 100mm diameter uPVC (or specified approved equivalent material), including bends, sockets, clips/supports at 1.0m intervals, and end outlet to ditch. Extend from downpipe discharge point to nearest ditch location as directed on site. Ensure minimum continuous fall of 1:100 towards ditch. All joints watertight. ml 145.00 0.00
Total carried to summary USD 0.00
2 FIR FIGHTING SYSTEM
2.1 Supply, install, test, and commission approved quality automatic fire water pump set (electric pump, diesel driven pump, and jockey pump) on common heavy-duty steel base plate (hot-dip galvanized, anti-vibration mounts) complete with all accessories, piping, valves, instrumentation, controls, civil works, testing, commissioning, training, and documentation as specified herein. 1.0 Single NFPA 20 Design Basis: The fire pump system shall be designed, supplied, and installed as a single integrated NFPA 20 system comprising electric duty pump, diesel standby pump, and jockey pump on a common skid. The design shall be based on a single hydraulic duty point: 200 GPM (12.62 L/s) @ 82 m head (119 psi). All components shall be selected and matched to this single design basis. The system shall be factory-tested as a complete assembly to verify performance at rated flow, shutoff, and 150% of rated flow. A certified pump performance curve shall be provided showing Head vs. Flow, Efficiency, Power (BHP), and NPSHR, with the operating design point clearly marked at 200 GPM @ 119 psi. 2.0 Pump Specifications: Referenced Aurora 2-384-11 @ 2,950 RPM or equivalent approved for the design duty point: Electric Pump (Primary Duty): 200 GPM (12.62 L/s) @ 149 psi (10.3 bar / 103 m) [exceeds design head of 119 psi], 30 hp (22.4 kW), 400 V / 50 Hz / 3-phase, TEFC motor, with minimum 85% efficiency. Diesel Standby Pump: 200 GPM (12.62 L/s) @ 149 psi (10.3 bar / 103 m), diesel engine rated at 33 bhp (24.6 kW) minimum (includes 10% NFPA 20 safety factor over pump BHP), radiator-cooled, 24 V electric start, with automatic battery charger and two (2) 120 Ah batteries. Jockey Pump (Pressure Maintenance): 15 GPM (0.95 L/s) @ 90 m head (123 psi), 0.75 kW (1 hp), 400 V / 50 Hz / three-phase.The electric fire pump controller shall be provided with a Soft Starter type starter suitable for the 22.4 kW (30 hp), 400 V, 3-phase, 50 Hz motor, to provide controlled acceleration, limit inrush current, and minimize mechanical shock to the pump and piping system. The soft starter shall comply with IEC 60947-4-2 (BS EN 60947-4-2), be listed for fire pump service, and include a bypass contactor for full-load operation. 3.0 Pump Performance Curve: The supplier shall provide a certified pump performance curve for the complete pump set showing the following: (i) Head vs. Flow curve (in m and GPM) from shutoff to 150% of rated flow; (ii) Efficiency curve (percentage) across the full operating range; (iii) Power curve (BHP/kW) for both electric and diesel drivers; (iv) Net Positive Suction Head Required (NPSHR) curve; (v) Operating point clearly marked at 200 GPM @ 149 psi. The curve shall be certified by the manufacturer and submitted with the equipment. 4.0 Skid Assembly: Factory-assembled, tested, and mounted on common heavy-duty steel base plate (hot-dip galvanized, anti-vibration mounts, lifting lugs). Physical dimensions: 2,600 mm (L) × 1,500 mm (W) × 1,800 mm (H) nominal. Integrated diesel fuel tank (minimum 200 Liters capacity) incorporated within the skid base structure. The complete skid assembly shall be installed at 400 mm above the pump room finished floor level (FFL) on a purpose-built reinforced concrete plinth. 5.0 Piping and Valves: Common suction manifold (DN 150) and delivery manifold (DN 100) with flanged connections; suction gate valves; delivery check valves (silent type); delivery gate valves; pressure relief valve (set at 9.65 bar/140 psi); air release valves; stop/isolation valves; Y-type suction strainer with blow-down and differential pressure gauge; test valve with drain pipe; flow meter (electromagnetic type, DN 100 with digital display); 2-way test header (DN 80 with two DN 65 hose connections). Flexible pipe connections shall be provided at suction and discharge to isolate vibration and allow for thermal movement. 6.0 Instrumentation and Controls: NFPA 20 compliant controller with automatic/manual operation, addressable, compatible with electric and diesel pumps; pressure sensors with manometers; pressure gauges (0–16 bar range with siphons); flow switch with alarm; pressure switch integration (6.9 bar/100 psi start pressure, adjustable); alarms (pump running, phase failure, low suction, engine faults, battery failure, fuel low, leak detection, pump on automatic, power available); remote monitoring dry contacts; weekly test timer; IP54 enclosure. 7.0 Diesel Fuel Tank: Double-walled steel tank with leak detection interstitial space; minimum 200 Liters capacity (sized for 12 hours run time per NFPA 20 Section 11.4.1.3.1); mechanical fuel level gauge; lockable fill cap with spill basin; drain valve; vent pipe with flame arrestor; complete fuel supply piping (flexible hose, isolation valve, filter). The tank shall be integrated into the skid base structure at the bottom of the skid frame. 8.0 Exhaust System (Diesel Standby Pump): Flexible stainless steel connector; critical grade silencer; schedule 40 steel exhaust pipe with rain cap; heat insulation where accessible with galvanized supports. Exhaust pipe shall be routed through the roof with weatherproof penetration. 9.0 Civil Assistance Works: Reinforced concrete plinth (300 mm height above pump room FFL) with dimensions adequate to support the skid footprint (minimum 2,400 mm × 1,600 mm × 300 mm) constructed of 25 MPa reinforced concrete. Plinth shall include anchor bolts with templates, load-bearing capacity to support skid weight plus full water content and dynamic loads, finished surface with slope to drain, drainage channel at plinth perimeter, ventilation louvers for engine cooling and combustion air, wall/roof penetration sleeves with fire-resistant sealant, and finished floor sloped to drain. The raised plinth shall provide flood protection and facilitate maintenance access to the skid unit. 10.0 Testing and Commissioning: Pressure testing (1.5 MPa/15 bar for 2 hours, no leakage); flow testing (rated flow and churn); diesel engine 1-hour full load run test; battery load test; full system commissioning as per NFPA 20. The complete skid assembly shall be tested as a single integrated unit to verify performance against the certified pump curve. 11.0 Documentation: Manufacturer's certificates; certified pump performance curves (Head vs. Flow, Efficiency, Power, NPSHR); driver kW ratings for electric motor (22.4 kW/30 hp) and diesel engine (33 bhp/24.6 kW minimum); controller specifications with wiring diagrams; NFPA 20 compliance documentation; test reports; commissioning report; warranties (12 months); O&M manuals (English/Arabic); as-built drawings; spare parts list; site training (2 days, 4 persons). 12.0 Compliance and Certification: NFPA 20 (latest edition); UL Listed / FM Approved (or equivalent) for fire protection service. Reference Brand/Model: Approved manufacturer's EDJ Series Fire Pump Skid (End Suction, Electric + Diesel + Jockey, 200 GPM @ 149 psi configuration) or approved equivalent. 13.0 Electrical Power Supply Requirements: The electrical supply shall be designed to support the fire pump system with the following connected loads: Main fire pump motor: 22.4 kW (30 hp), 400 V / 3-phase / 50 Hz, 45 A full load current; Jockey pump motor: 0.75 kW (1 hp), 400 V / 3-phase / 50 Hz, 2.0 A; Electric motor controller: 0.50 kW, 400 V / 3-phase / 50 Hz, 1.5 A; Diesel engine controller: 0.30 kW, 230 V / single-phase, 2.5 A; Battery charger (diesel): 0.30 kW, 230 V / single-phase, 1.5 A. Total connected load (electric): 23.65 kW. A dedicated 100 A, 3-phase circuit breaker. Notes: All works in accordance with manufacturer's instructions and locations shown on drawings. Price includes all necessary accessories required for proper operation but not specified or shown. Final physical dimensions to be confirmed by selected manufacturer. The raised plinth (300 mm above FFL) shall be constructed prior to skid installation. The single NFPA 20 design basis shall be documented with the certified pump curve, driver kW ratings, and controller specifications submitted as part of the equipment supply. SET 1.00 0.00
2.2 Supply, install, test, and commission fire water piping from GRP water tank fire reserve compartment to four (4) Class II hose reel cabinets, complete with DN 80 (3 inch) Schedule 40 black steel main pipe (ASTM A53 Grade B), DN 50 (2 inch) Schedule 40 branch pipes, all necessary fittings (90° and 45° elbows, tees, reducers), DN80 PN16 gate valves (bronze, rising stem) at tank outlet and pump discharge, DN50 PN16 gate valves at each hose reel branch (4 units), DN80 swing check valve at pump discharge, pressure gauge (0–200 psi) with siphon and isolation valve, 2-way test header with 65 mm hose connections, expansion joints (as required), galvanized steel pipe supports and hangers spaced per NFPA 14 Table 10.6.3.2.1, threaded or grooved joints (no welding unless specified), underground section (500 mm cover, sand bedding, anti-corrosion PET/bituminous wrap), exposed section with two coats of red epoxy fire-resistant paint (150 µm DFT, Sa 2.5 surface preparation), and clear labeling in English and Arabic (red bands/stickers at 10 m intervals stating "FIRE MAIN – HOSE REEL SYSTEM"). Pipe routing to cover total length of 150 meters (the unit price shal include fittings) as per design report, connecting to hose reel cabinets located in Crop Market Block (2 cabinets) and Vegetable Market Block (2 cabinets). Include full hydrostatic pressure test (15 bar for 2 hours, no leakage), flow test (757 L/min at ≥100 psi at most remote outlet), and flushing. Provide mill certificates, valve test reports, hydrostatic test report, flow test report, and as-built drawings. SET 1.00 0.00
2.3 Fire Hose Reel Cabinet Assembly (Class II) – Supply, install, and commission one complete Class II hose reel assembly conforming to NFPA 14, including: stainless steel/steel cabinet (1.2 mm thickness) with transparent panel, 30 m rubber-lined hose (19 mm internal diameter, 15 bar pressure rating), shut-off nozzle (6 mm orifice, solid stream/spray pattern), 1.5-inch (38 mm) inlet connection, non-return valve, angle valve with quick-release coupling. Mount at 1.2 m height to center of operating handle. Include red reflective labeling in English and Arabic. № 4.00 0.00
2.4 Portable Fire Extinguisher (ABC Dry Chemical) – Supply and mount one portable fire extinguisher, ABC dry chemical type (monoammonium phosphate, minimum 90%), stored-pressure type with metal valve body, pressure gauge with green zone indicator, corrosion-resistant finish, rating as specified, wall mounting bracket, inspection tag, and operating instructions in English and Arabic. № 14.00 0.00
2.5 Ditto ( 2.4) but CO2 type for pump/ control/panel room № 2.00 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.4.1- Multi Purpose Hall Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 GLAZING USD 0.00
8 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 230.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 115.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 189.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 19.00 0.00
1.5 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 27.00 0.00
1.6 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 100.00 0.00
1.7 Ditto as above item 1.5 but around isolated footing. m3 167.00 0.00
1.8 Ditto as above item 1.5 but around masonry foundation wall. m3 10.00 0.00
1.9 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 394.00 0.00
1.1 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 153.00 0.00
1.11 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 108.00 0.00
1.12 Ditto as above item 1.10 but construction joint between grade slab & grade slab where the slab area is larger. ml 28.00 0.00
1.13 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 93.00 0.00
2.1.2 Under masonry foundation wall m2 36.00 0.00
2.1.3 Under grade beam m2 8.00 0.00
2.1.4 Under slab on grade including ramp. m2 153.00 0.00
2.1.5 Under masonry steps on grade m2 1.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 34.00 0.00
2.2.2 In foundation column. m3 2.60 0.00
2.2.3 In grade beams. m3 6.30 0.00
2.2.4 In 10 cm thick ground floor slab including ramps & outdoor tratment. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 153.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 59.00 0.00
2.3.2 To foundation column m2 35.00 0.00
2.3.3 To grade beams & ramps edge m2 49.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 8 mm deformed bar Kg 56.00 0.00
Dia 12 mm deformed bar Kg 1,246.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 145.00 0.00
Dia 16 mm deformed bar Kg 737.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 227.00 0.00
Dia 12 mm deformed bar Kg 407.00 0.00
Dia 16 mm deformed bar Kg 102.00 0.00
2.4.4 For floor slab on grade, ramp slab & outdoor tratment slab
Dia 8 mm deformed bar Kg 624.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 36.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 1.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 5.80 0.00
1.1.2 In top tie beams m3 5.40 0.00
1.1.3 In lintel beams including roof vent windows m3 0.80 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 77.00 0.00
1.2.2 To top tie beams m2 62.00 0.00
1.2.3 To lintel beams including for roof vent windows m2 14.00 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 253.00 0.00
Dia 16 mm deformed bar Kg 839.00 0.00
1.3.2 For top tie beam
Dia 8 mm deformed bar Kg 227.00 0.00
Dia 12 mm deformed bar Kg 407.00 0.00
Dia 16 mm deformed bar Kg 102.00 0.00
1.3.3 For water tanker slab & beam
Dia 6 mm deformed bar Kg 24.00 0.00
Dia 12 mm deformed bar Kg 90.00 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for plastering. m2 173.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 192.00 0.00
3.2 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet ridge cup at the roof slope direction changes. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of ridge cap: 80 cm. m.l. 21.00 0.00
3.3 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 41.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors and windows all as per the drawing. All doors & windows should have vertical metal grill 25x25x2mm c/c 15cm behind glazing for burglar proofing. Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint. (glazing measured separately).
D-1 size 200cm x 360cm no 1.00 0.00
D-2 size 100cm x 360cm no 2.00 0.00
W-1 size 140cm x 250cm no 12.00 0.00
4.2 Supply, fabricate and fix metal ramp handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 3.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect steel structures using RHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards. Price shall include gusset plat, connection plate when truss members connect and bolts other than anchor/J-bolt bolts.
A.1 RHS 80 x 80 x 4mm upper & lower truss member for T1 Kg 1,100.00 0.00
A.2 RHS 60 x 60 x 4mm diagonal & vertical truss member for T1 Kg 695.00 0.00
B. RHS Purlins 0.00
B.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 40 x 40 x 3mm L= 40mm angle iron. Price include angle iron. Kg 1,526.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate for verenda post-size 250 x 250 x 6mm with 4 dia 18 slotted holes. The plated is welded to the RHS post (fillet weld of 3mm throat thickness) and connected to the other plate fixed on concrete column. No 24.00 0.00
A.2 Gussate plate size 200 x 160 x 6mm. The plate is welded to the truss (fillet weld of 3mm throat thickness) No 12.00 0.00
A.3 Gussate plate size 300 x 160 x 6mm. The plate is welded to the truss (fillet weld of 3mm throat thickness) No 24.00 0.00
A.4 Metal plate 40x200x3 welded to truss and bolted to angle iron-2 ∅8mm bolt to connect angle iron to metal plate No 72.00 0.00
B Bolt with nut
B.1 Base plate/Anchor bolt dia. 16 Length 250mm for truss beam connection and to be weld to ring beam steel reinforcement No 48.00 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of fine cement sand finish to internal brick wall surfaces. m2 177.00 0.00
6.2 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of fine cement sand finish to internal exposed beam and column surfaces. m2 21.00 0.00
6.3 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive rendering finish to externall brick wall surfaces. m2 146.00 0.00
6.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final rendering finish to external exposed beam and column surfaces. m2 41.00 0.00
6.5 Prepare the surface and apply final a 3 mm to 5 mm thick final skim coat using a 1:3 cement-to-fine-sand mortar mix. Fine sand must be sieved through a 1.18 mm mesh. The surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks to internal wall, beam & column surfaces. m2 198.00 0.00
6.6 Prepare the surface and apply final apply 15mm thick cement and sand rendering (1:3 mix) for external wall surface. Price includes surface preparation, hacking of concrete surfaces, wire mesh for joints, curing for 7 days. The rendering pattern shall be as per the Architect approval. m2 187.00 0.00
6.7 Prepare the surface, supply and construct 2 cm thick x 25 cm wide polished marble threshold for doors bedded on cement sand mortar 1:3. Price include 30mm thick cement sand mortar backing and white cement grouting. All are as per the detail Ar. Dwg. ml 4.00 0.00
6.8 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 155.00 0.00
6.9 10cm high 1cm thick chamfered ceramic skirting of matching color to floor tiles. ml 74.00 0.00
6.10 Supply and fix granite stair tread bedded on cement mortar 1:3 price include mortar bed, nosing and chamfering. Color and pattern shall be approved by the Architect.
a) For entrance step-tread
- Tread size: (33 x 3 cm) ml 4.20 0.00
6.11 Ditto as above but riser.
a) For entrance step-rise
- riser size: (13.4 x 2 cm) ml 4.20 0.00
6.12 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick terrazzo window sill. Price shall include cement sand mortar bed and cement grouting. ml 17.00 0.00
6.13 Supply and fix chamfered, bullnose and water dripped 25 x 3cm thick terrazzo edge trim for veranda edge. Price shall include cement sand mortar bed and cement grouting. ml 12.00 0.00
6.14 Supply and fix approved quality 60 x 60cm gypsum board suspended ceiling as per the detail drawing and engineers approval. The fixing method shall be with T & L aluminum suspension syste. Price shall include gypsum, suspension systemcorner list, nails and all the necessary fixing accessories. m2 155.00 0.00
6.15 10 cm thick Concrete pavement around the building bedded on 10 cm thick red ash or fine aggregate and 20cm thick compacted granular materials. The work shall be mixing, placing, compacting, curing, and finishing of concrete with trowel finish while fresh. Price shall include red ash bed, selected fill and trowel finishing work. m2 58.00 0.00
Total Carried to summary USD 0.00
7.1 Supply and fix 0.5cm thick clear glass. Price shall include all the necessary fixing accessories. m2 42.00 0.00
7.2 Supply and fix 0.5cm thick figured glass. Price shall include all the necessary fixing accessories. m2 10.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
8.1 Apply three coats of plastic emulsion paint to internally plastered wall surfaces. m2 198.00 0.00
8.3 Ditto as item 8.1, but to chip wood ceiling. m2 155.00 0.00
8.3 Apply final acrylic emulsion point paint to external rendered wall surface, exposed R.C columns and beams. m2 187.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.4.2- Multi-Purpose Hall Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ELECTRICAL WORKS
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Flush-mounted sub distribution Board, SDB-MPH in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 25A,4P , Icu=10KA, coupled with RCD ,300mA, Type S/ Time delayed 0.00
3pc MCB of 20A, 2P, Icu=10KA
3pcs RCBO of 16A, 2P, Icu=6KA ,30mA 0.00
3pcs MCB of 10A, 2P, Icu=6KA
2pcs MCB of 16A, 2P (spare) Icu=10KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A, 3ph+N No 1.00 0.00
1.1.2 Flush-mounted sub distribution Board, SDB-UPS in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 20A, 2P, Icu=10KA ,coupled with RCD ,300mA, Type S/ Time delayed 0.00
3pcs RCBO of 16A, 2P, Icu=6KA, 30mA
2pcs MCB of 16A, 2P (spare) Icu=10KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A/1P+N. No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including unction boxes with covers insulating screw cap connectors complete. No 34.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L1 LED Panel Light: 600x600mm, 22.5W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 24.00 0.00
1.3.L2 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 4.00 0.00
1.3.(E) Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). IP65,IK08, 5700K, minimum 7W, autonomy 90min. Warranty: 3 years (components), 5 years (battery). No 5.00 0.00
1.3.(EX) Saftey only emergency with FLC 11SE or approved equivallent illuminated signage system shall be installed to give information with standard dimensions information displays and illumination level with double or single faces. The display consisting of symbols, text or figures supported with direction which will indicate EXIT, toilets (lady and gentlemen), staircases and floor level will be placed as indicated on the drawings throughout building for the convenience of the public and workers .The symbols, text or figures shall be choices of the client or engineer and shall be appropriate enough to describe the room, areas, services and all safety directions it should have emergency battery for at least 90min. No 1.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Double pole Switch No 4.00 0.00
1.4.2 Double pole Switch water proof for out door installation IP44. No 1.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 19.00 0.00
1.6 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.6.1 16A ,1ph ,230V 2p+e socket out let No 4.00 0.00
1.6.2 16A ,1ph,230V 2p+e socket out let water proof IP44. No 2.00 0.00
1.6.3 Dito but Double (Twin) Outlet No 6.00 0.00
1.6.4 Dito but Double (Twin) in Red for UPS Outlet No 7.00 0.00
Supply, install, test, and commission a 3.5 kVA, 230 V, single-phase online double-conversion UPS, complete with a minimum of 10 minutes of battery autonomy at full load, automatic static bypass, maintenance bypass, a sealed maintenance-free battery bank, intelligent battery charger, LCD display, pure sine wave output, power factor ≥ 0.9, and 95% efficiency in online mode. Communication interface, and all necessary protection, control, interconnecting cables, earthing, accessories, and mounting hardware. The UPS shall comply with IEC 62040-1, IEC 62040-2, and IEC 62040-3, and shall be complete with all materials and accessories required for a fully functional installation. No 1.00 0.00
1.8 DATA\ Telecome System 0.00
Tel/Data according to manufacturer’s and utility supplier’s requirements, supplied, installed, connected color coded including tags and tested, complete, all as specified and / or as shown on the drawings 0.00
Structured Cabling
Horizontal CAT6A Cabling
1.8.1 Tel/Data and Data/Data points fed through 2x(twisted pair category 6A UTP cable) inside FRLS PVC conduits of 20mm diameter and thickness not less than 1.5mm with conduits accessories (coupling, junction boxes) for tele/Data outlet socket. No 8.00 0.00
1.8.2 Cat 6A 24 port Patch Panel RJ 45 contact No 1.00 0.00
1.8.3 Cat 6A RJ 45 Patch Cord 0.5m, from switch to patch panels No 16.00 0.00
1.8.4 Cat 6A RJ 45 Patch Cord 3m, from outlets to workstation computers. No 8.00 0.00
Equipment Racking 0.00
1.8.5 Wall Mount metallic rack of 9U pivoting cabinet swing 19" steel enclosure with transparent and lockable door, Built-in PDUs (8-10 Outlets, Grounded) and cooling fans. No 1.00 0.00
1.8.6 1U Horizontal Cable Management Bars, 5 Vertical Plastic Hoops with Cover No 2.00 0.00
Information Outlets: Data &Voice 0.00
Extra Over Data Socket Outlets with Detachable Frames & Corresponding Box 0.00
1.8.7 2 x RJ45 8 Contact CAT6a Socket Outlets No 6.00 0.00
Active components Type CISCO or approved equivalent. 0.00
1.8.8 24-port Gigabit Data +2x10G uplink Switch . No 1.00 0.00
1.8.9 24 port voice patch panel for telephone connection No 1.00 0.00
1.8.10 Hybrid PBX with 24 Analog, with 4 trunk, Extension including Operator Phone No 1.00 0.00
1.8.11 Cat 6A RJ 11 Patch Cord 1m No 8.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.4.3- Multi-Purpose Hall Building-Sanitary
1 SANITARY EQUIPMENT & WATE PIPES USD 0.00
1 ROOF RAIN WATER DOWN PIPING SYSTEM USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.0 SANITARY EQUIPMENET ( FIXTURES )
All fixtures which are specified below is subject to the owner's / consultant's approval, based on samples, catalogues and brochures presented by the contractor. Unit price shall include all the necessary fixing brackets or hooks and all assistance civil works such as chiseling of walls, floors, beams and etc.
1.1 HAND WASH BASIN (ORDINARY)
Supply and fix R.A.K. or Equivalent, hand wash basins for first aid room made of white glazed vitreious china with REMER/JAQUAR or Equivalent chrome plated cold water tap, pedastal stand ,complete with stop & arrest valves on water inlet pipe. Chrome plated chain holder, P-smell trap with connection pipe, fittings, all other necessary etc.complete in all respects. Flexible hose to be REMER or Equivalent and should be capable of resisting pressure of 4 bar. P-smell trap should be brass chrome plated with 50mm height of water seal and trap. The unit price shall include 500ml automatic soap dispenser,crystal glass mirror of 500 x 400mm.
a) Size :- length X width (1000mm x 435mm) set 1.00 0.00
1.2 Supply, fix, test and commission floor drains made of polished steel, complete with P-smell trap /minimum seal depth 75mm/ and all other necessary fittings and accessories. No 1.00 0.00
1.3 Waste & vent Pipes and Accessories
All domestic waste pipe lines shall be uPVC (PN4) pipes and shall be provided with a minimum slope of 2% towards the outlet. All uPVC pipes and necessary fittings shall be standard quality and be free from damage during storage, construction and etc. Unit price shall include all the necessary assistance civil works, such as excavation cartaway, fixing or hanging to walls, beams or slabs.etc., necessary fittings such as bends, Y, T, FCO(Floor clean out) etc.
Dia. 50 mm ml 6.00 0.00
Total carried to summary USD 0.00
1.0 ROOF RAIN WATER DOWNPIPING SYSTEM
3.2 Rainwater Downpipe DN 100 (Office + Multipurpose Hall) – Supply, install, test, and commission one uPVC rainwater downpipe, DN 100 mm nominal diameter, conforming to ISO 1452-1 or AS/NZS 1260, minimum wall thickness 2.5 mm. Include stainless steel leaf guard (5 mm mesh) at roof inlet, galvanized pipe brackets (vertical spacing 1.8 m maximum, horizontal spacing 1.0 m maximum), UV-reflective light-colored oil paint coating (white/light grey) conforming to ISO 4892-2 on all exposed sections, and discharge splash block at base. Complete from roof outlet to ditch/splash block. ml 20.00 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.5.1- Security/Guard House Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 GLAZING USD 0.00
8 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 50.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 25.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 18.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 2.00 0.00
1.5 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 7.00 0.00
1.6 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 21.00 0.00
1.7 Ditto as above item 1.5 but around isolated footing. m3 17.00 0.00
1.8 Ditto as above item 1.5 but around masonry foundation wall. m3 4.00 0.00
1.9 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 61.00 0.00
1.1 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 19.00 0.00
1.11 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 15.00 0.00
1.12 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 7.00 0.00
2.1.2 Under masonry foundation wall m2 13.00 0.00
2.1.3 Under slab on grade including ramp. m2 19.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 1.75 0.00
2.2.2 In foundation column. m3 0.50 0.00
2.2.3 In grade beams. m3 1.20 0.00
2.2.4 In 10 cm thick ground floor slab including ramps & outdoor tratment. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 19.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 6.00 0.00
2.3.2 To foundation column m2 8.00 0.00
2.3.3 To grade beams & ramps edge m2 10.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 12 mm deformed bar Kg 85.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 29.00 0.00
Dia 16 mm deformed bar Kg 92.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 47.00 0.00
Dia 12 mm deformed bar Kg 98.00 0.00
2.4.4 For floor slab on grade & ramp slab
Dia 8 mm deformed bar Kg 77.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 13.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 1.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 0.75 0.00
1.1.2 In top tie beams m3 1.20 0.00
1.1.3 In lintel beams including roof vent windows m3 0.20 0.00
1.1.4 In lnternal partition tie beam m3 0.20 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 12.00 0.00
1.2.2 To top tie beams m2 14.00 0.00
1.2.3 To lintel beams including for roof vent windows m2 3.00 0.00
1.2.4 To internal partition tie beam m2 2.00 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 38.00 0.00
Dia 16 mm deformed bar Kg 199.00 0.00
1.3.2 For top tie beam
Dia 8 mm deformed bar Kg 47.00 0.00
Dia 12 mm deformed bar Kg 98.00 0.00
1.3.3 For lintel beam
Dia 6 mm deformed bar Kg 4.00 0.00
Dia 12 mm deformed bar Kg 15.00 0.00
1.3.4 For internal partition tie beam
Dia 8 mm deformed bar Kg 9.22 0.00
Dia 12 mm deformed bar Kg 19.54 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for plastering. m2 44.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 18.00 0.00
3.2 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 12.00 0.00
3.3 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 5.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors and windows all as per the drawing. All doors & windows should have vertical metal grill 25x25x2mm c/c 15cm behind glazing for burglar proofing. Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint. (glazing measured separately).
D-1 size 90cm x 210cm no 2.00 0.00
W-1 size 140cm x 120cm no 2.00 0.00
4.2 Supply, fabricate and fix metal ramp handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 5.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect steel structures using RHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel rafter
Steel rafters and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards. Price shall include gusset plat, connection plate when truss members connect and bolts other than anchor/J-bolt bolts.
A.1 RHS 100 x 60 x 3mm rafter Kg 63.00 0.00
B. RHS Purlins 0.00
B.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 40 x 40 x 3mm L= 40mm angle iron. Price include angle iron. Kg 129.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate for verenda post-size 250 x 150 x 6mm with 4 dia 18 slotted holes. The plated is welded to the RHS post (fillet weld of 3mm throat thickness) and connected to the other plate fixed on concrete column. No 8.00 0.00
A.2 Angle late size 150 x 150 x 6mm. The plate is welded to the rafter (fillet weld of 3mm throat thickness) No 8.00 0.00
A.3 Gussate plate size 40 x 200 x 3mm. The plate is welded to the truss (fillet weld of 3mm throat thickness) and bolted with 2 dia. 8mm bolt. Price include bolt No 12.00 0.00
B Bolt with nut
B.1 Base plate/Anchor bolt dia. 16 Length 250mm for truss beam connection and to be weld to ring beam steel reinforcement No 12.00 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final/third coat of fine cement sand finish to internal brick wall surfaces. m2 49.00 0.00
6.2 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of fine cement sand finish to internal exposed beam and column surfaces. m2 3.00 0.00
6.3 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive rendering finish to externall brick wall surfaces. m2 45.00 0.00
6.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final rendering finish to external exposed beam and column surfaces. m2 12.00 0.00
6.5 Prepare the surface and apply final a 3 mm to 5 mm thick final skim coat using a 1:3 cement-to-fine-sand mortar mix. Fine sand must be sieved through a 1.18 mm mesh. The surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks to internal wall, beam & column surfaces. m2 52.00 0.00
6.6 Prepare the surface and apply final apply 15mm thick cement and sand rendering (1:3 mix) for external wall surface. Price includes surface preparation, hacking of concrete surfaces, wire mesh for joints, curing for 7 days. The rendering pattern shall be as per the Architect approval. m2 57.00 0.00
6.7 Prepare the surface, supply and construct 2 cm thick x 25 cm wide polished marble threshold for doors bedded on cement sand mortar 1:3. Price include 30mm thick cement sand mortar backing and white cement grouting. All are as per the detail Ar. Dwg. ml 1.00 0.00
6.8 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 13.00 0.00
6.9 10cm high 1cm thick chamfered ceramic skirting of matching color to floor tiles. ml 19.00 0.00
6.1 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick terrazzo window sill. Price shall include cement sand mortar bed and cement grouting. ml 3.00 0.00
6.11 Supply and fix approved quality 60 x 60cm gypsum board suspended ceiling as per the detail drawing and engineers approval. The fixing method shall be with T & L aluminum suspension syste. Price shall include gypsum, suspension systemcorner list, nails and all the necessary fixing accessories. m2 13.00 0.00
6.12 10 cm thick Concrete pavement around the building bedded on 10 cm thick red ash or fine aggregate and 20cm thick compacted granular materials. The work shall be mixing, placing, compacting, curing, and finishing of concrete with trowel finish while fresh. Price shall include red ash bed, selected fill and trowel finishing work. m2 9.00 0.00
Total Carried to summary USD 0.00
7.1 Supply and fix 0.5cm thick clear glass. Price shall include all the necessary fixing accessories. m2 3.36 0.00
7.2 Supply and fix 0.5cm thick figured glass. Price shall include all the necessary fixing accessories. m2 1.08 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
8.1 Apply three coats of plastic emulsion paint to internally gypsum plastered wall surfaces. m2 52.00 0.00
8.3 Ditto as item 8.1, but to chip wood ceiling. m2 13.00 0.00
8.3 Apply final acrylic emulsion point paint to external rendered wall surface, exposed R.C columns and beams. m2 57.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.5.2- Security/Guard House Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ELECTRICAL WORKS
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Flush-mounted sub distribution Board, SDB-SR1 in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 20A, 2P , Icu=10KA, coupled with RCD ,300mA, Type S/ Time delayed 0.00
1pcs RCBO of 16A, 2P, Icu=6KA ,30mA 0.00
1pcs MCB of 10A, 2P, Icu=6KA
1pcs MCB of 16A, 2P (spare) Icu=10KA 0.00
1Pc of surge arrestor of 20KA, Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A/1P+N. No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 6.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L1 LED Panel Light: 600x600mm, 22.5W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 1.00 0.00
1.3.L2 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 3.00 0.00
1.3.L3 Circular LED Ceiling Light D230, 13W, 400K,1300Lumen CRI > 80, ceiling-mounted, aluminum with acrylic diffuser, IP44, flicker-free. No 2.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Single Pole 1-Way Switch No 2.00 0.00
1.4.2 Single Pole 1-Way Switch, weather-proof IP54 No 1.00 0.00
1.4.3 Two Way Switch No 2.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 5.00 0.00
1.5 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.5.1 16A ,1ph ,230V 2p+e socket out let No 4.00 0.00
1.5.2 Dito but Double (Twin) Outlet No 1.00 0.00
1.6 DATA\ Telecome System 0.00
Tel/Data according to manufacturer’s and utility supplier’s requirements, supplied, installed, connected color coded including tags and tested, complete, all as specified and / or as shown on the drawings 0.00
1.6.1 2 x RJ45 8 Contact CAT6a Socket Outlets No 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.5.3- Security/Guard House Building-Sanitary
1 ROOF RAIN WATER DOWNPIPING SYSTEM USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ROOF RAIN WATER DOWN PIPING SYSTEM
1.1 Rainwater Downpipe DN 80 (Guard House) – Supply, install, test, and commission one uPVC rainwater downpipe, DN 80 mm nominal diameter, conforming to ISO 1452-1 or AS/NZS 1260, minimum wall thickness 2.0 mm. Include stainless steel leaf guard (5 mm mesh) at roof inlet, galvanized pipe brackets (vertical spacing 1.8 m maximum, horizontal spacing 1.0 m maximum), UV-reflective light-colored oil paint coating (white/light grey) conforming to ISO 4892-2 on all exposed sections, and discharge splash block at base. Complete from roof outlet to ditch/splash block. ml 20.00 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.6.1- Toilet -Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 156.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 78.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 36.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 4.00 0.00
1.5 Pit excavation for pit latrin in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 100 cm working space in each side for pit excavation. m3 80.00 0.00
1.5 Ditto as above item 1.5 but from 150cm to 300cm m3 32.00 0.00
1.6 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 11.00 0.00
1.7 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 69.00 0.00
1.8 Ditto as above item 1.7 but around isolated footing. m3 35.00 0.00
1.9 Ditto as above item 1.7 but around pit laterin shear wall m3 79.00 0.00
1.10 Ditto as above item 1.7 but around masonry foundation wall. m3 7.00 0.00
1.11 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 270.00 0.00
1.1 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 57.00 0.00
1.11 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 68.00 0.00
1.12 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 16.00 0.00
2.1.2 Under masonry foundation wall m2 23.00 0.00
2.1.3 Under grade beam m2 3.00 0.00
2.1.4 Under slab on grade including ramp. m2 57.00 0.00
2.2 10 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :under pit latterin bottom slab. 29.00 0.00
2.3 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.3.1 In isolated footing. m3 4.05 0.00
2.3.2 In foundation column. m3 0.80 0.00
2.3.3 In grade beams. m3 4.60 0.00
2.3.4 In 10 cm thick ground floor slab including ramps & outdoor tratment. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 57.00 0.00
2.3.5 In 15cm thick ramp slab. m2 3.00 0.00
2.3.6 In pit laterin bottom slab, shear wall & top slab m3 25.00 0.00
2.4 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.4.1 To isolated footing. m2 11.00 0.00
2.4.2 To foundation column m2 12.00 0.00
2.4.3 To grade beams & ramps edge m2 30.00 0.00
2.4.4 To pit latrin slab & shear wall m2 120.00 0.00
2.5 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.5.1 For footing pad
Dia 8 mm deformed bar Kg 13.00 0.00
Dia 12 mm deformed bar Kg 192.00 0.00
2.5.2 For Foundation column
Dia 8 mm deformed bar Kg 97.00 0.00
Dia 16 mm deformed bar Kg 343.00 0.00
2.5.3 For grade beam
Dia 8 mm deformed bar Kg 207.00 0.00
Dia 12 mm deformed bar Kg 404.00 0.00
2.5.4 For floor slab on grade, ramp slab
Dia 8 mm deformed bar Kg 247.00 0.00
Dia 10 mm deformed bar Kg 12.00 0.00
2.5.5 For fpit laterin
Dia 12 mm deformed bar Kg 3,170.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 23.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 1.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 2.40 0.00
1.1.2 In top tie beams m3 3.65 0.00
1.1.3 In internal partition tie beams m3 1.32 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 28.00 0.00
1.2.2 To top tie beams m2 42.00 0.00
1.2.2 To internal partition tie beams m2 13.20 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 154.00 0.00
Dia 16 mm deformed bar Kg 249.00 0.00
1.3.2 For top tie beam
Dia 8 mm deformed bar Kg 139.00 0.00
Dia 12 mm deformed bar Kg 278.00 0.00
1.3.3 For internal partition tie beam
Dia 8 mm deformed bar Kg 60.83 0.00
Dia 12 mm deformed bar Kg 117.22 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for plastering. m2 131.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 75.00 0.00
3.2 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 23.00 0.00
3.3 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 16.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors and windows all as per the drawing. All doors infill/covered with 0.5mm thick flat metal sheet pannel & windows should have infil with vertical metal grill 25x25x2mm c/c 15cm . Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint.
D-1 size 100cm x 200cm no 2.00 0.00
D-2 size 80cm x 200cm no 10.00 0.00
W-1 size 60cm x 40cm no 12.00 0.00
4.2 Supply, fabricate and fix metal ramp handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 11.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect steel structures using RHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel rafter
Steel rafters and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards. Price shall include gusset plat, connection plate when truss members connect and bolts other than anchor/J-bolt bolts.
A.1 RHS 100 x 60 x 3mm rafter Kg 201.00 0.00
B. RHS Purlins 0.00
B.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 40 x 40 x 3mm L= 40mm angle iron. Price include angle iron. Kg 519.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate for verenda post-size 250 x 150 x 6mm with 4 dia 18 slotted holes. The plated is welded to the RHS post (fillet weld of 3mm throat thickness) and connected to the other plate fixed on concrete column. No 12.00 0.00
A.2 Angle late size 150 x 150 x 6mm. The plate is welded to the rafter (fillet weld of 3mm throat thickness) No 12.00 0.00
A.3 Gussate plate size 40 x 200 x 3mm. The plate is welded to the truss (fillet weld of 3mm throat thickness) and bolted with 2 dia. 8mm bolt. Price include bolt No 36.00 0.00
B Bolt with nut
B.1 Base plate/Anchor bolt dia. 16 Length 250mm for truss beam connection and to be weld to ring beam steel reinforcement No 24.00 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final/third coat of fine cement sand finish to internal brick wall surfaces. m2 140.00 0.00
6.2 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of fine cement sand finish to internal exposed beam and column surfaces. m2 18.00 0.00
6.3 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive rendering finish to externall brick wall surfaces. m2 104.00 0.00
6.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final rendering finish to external exposed beam and column surfaces. m2 33.00 0.00
6.5 Prepare the surface and apply final a 3 mm to 5 mm thick final skim coat using a 1:3 cement-to-fine-sand mortar mix. Fine sand must be sieved through a 1.18 mm mesh. The surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks to internal wall, beam & column surfaces. m2 158.00 0.00
6.6 Prepare the surface and apply final apply 15mm thick cement and sand rendering (1:3 mix) for external wall surface. Price includes surface preparation, hacking of concrete surfaces, wire mesh for joints, curing for 7 days. The rendering pattern shall be as per the Architect approval. m2 137.00 0.00
6.7 Prepare the surface, supply and construct 2 cm thick x 25 cm wide polished marble threshold for doors bedded on cement sand mortar 1:3. Price include 30mm thick cement sand mortar backing and white cement grouting. All are as per the detail Ar. Dwg. ml 14.00 0.00
6.8 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 59.00 0.00
6.13 Supply and fix 30 x 60 x 0.85 cm ceramic wall cladding, of matching color to floor, stuck to wall with cement sand mortar 1:3 backing and grouting with white cement wash. Price shall include rod anchors to backing. Size, color and pattern according to architect's drawings. m2 168.00 0.00
6.12 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick terrazzo window sill. Price shall include cement sand mortar bed and cement grouting. ml 8.00 0.00
6.15 10 cm thick Concrete pavement around the building bedded on 10 cm thick red ash or fine aggregate and 20cm thick compacted granular materials. The work shall be mixing, placing, compacting, curing, and finishing of concrete with trowel finish while fresh. Price shall include red ash bed, selected fill and trowel finishing work. m2 12.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
7.1 Apply three coats of plastic emulsion paint to internally gypsum plastered wall surfaces. m2 158.00 0.00
7.3 Apply final acrylic emulsion point paint to external rendered wall surface, exposed R.C columns and beams. m2 137.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.6.2- Toilet Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Flush-mounted sub distribution Board, SDB-TO-1 in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 16A, 2P , Icu=10KA, coupled with RCD ,300mA, Type S/ Time delayed 0.00
2pcs MCB of 10A, 2P, Icu=6KA
1pcs MCB of 10A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A/1P+N. No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 24.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W,4000K, 3600Lumen, CRI > 80, ceiling-mounted, polycarbonate, flicker-free, IP66, for outdoor instalation No 10.00 0.00
1.3.L3 Circular LED Ceiling Light D230, 13W, 400K,1300Lumen CRI > 80, ceiling-mounted, aluminum with acrylic diffuser, IP44, flicker-free. No 12.00 0.00
1.3.(E) Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). IP65,IK08, 5700K, minimum 7W, autonomy 90min. Warranty: 3 years (components), 5 years (battery). No 2.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Single Pole 1-Way Switch No 2.00 0.00
1.4.2 Double pole Switch No 3.00 0.00
1.4.3 Double pole Switch Weather proof for outdoor installation, IP54 No 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.6.3- Toilet Building-Sanitary
1 WATER SUPPLY SYSTEMS USD 0.00
2 WASTE WATER DRAINAGE SYSTEMS USD 0.00
3 ROOF RAIN WATER DOWNPIPING SYSTEM USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 WATER SUPPLY SYSTEMS
1.1 Water Supply Piping Systems
1.1.1 Polypropylene Random Copolymer (PPR) pipe system for gravity-fed water supply from EWT to faucet, PN10, complete with all necessary fittings,elbow,stop valve,coupler,adapter,wall brackets, joints, and accessories for a fully functional system. Pipe and fittings shall comply with ISO 15874 / DIN 8077/8078. The unit price shall include Low-pressure wall-mounted faucet, complete with: swivel spout, aerator, lever-operated handle, wall mounting plate, fixing screws, and all necessary accessories. Faucet shall be certified for operation at minimum 0.1 bar residual pressure.
PPR pipe, DN20, PN10, SDR 11 lm 6.00 0.00
1.1.2 Supply, deliver, mount, test, and commission a hot press molded sectional Glass Reinforced Plastic (GRP) water tank system with total effective capacity of 36,000 liters (36 m³), comprising fire reserve compartment (27,000 liters / 27 m³) and domestic/non-potable water compartment (9,000 liters / 9 m³) separated by a watertight GRP partition, with individual connections and isolation valves for each compartment to allow independent operation and maintenance. Tank to be manufactured from food-grade GRP material conforming to ISO 14692, complying with NFPA 22 (fire reserve) and WRAS/NSF 61 (domestic water), with external hot-dip galvanized steel bracing (ISO 1461) and UV-resistant coating (ISO 4892-2). Designed for atmospheric working pressure with minimum 300 mm freeboard and shall withstand hydrostatic test pressure of 1.5 times the design head. Tank to be installed at ground level on a reinforced concrete slab (minimum 500 mm thick) raised 500 mm above NGL for flood protection, with steel rebar reinforcement (12 mm diameter @ 200 mm centers) extending minimum 300 mm beyond the tank footprint, and 150 mm high flood curb around slab perimeter. Complete with lockable manhole cover (minimum 600 mm diameter) with insect-proof vent, screened vent with 12 mm mesh, internal GRP ladder, external aluminum ladder with anti-slip platform and guardrails (ISO 14122), mechanical "Cat and Mouse" water level indicator or ultrasonic level sensor (one per compartment), sampling tap for water quality testing, earth bonding connection, fall protection anchor point, and the following connections: DN50 PN16 inlet with bronze gate valve and float valve, DN50 PN16 domestic outlet with bronze gate valve and expansion joint, DN80 PN16 fire outlet with bronze gate valve and expansion joint, DN50 drain with bronze gate valve and scour outlet, and DN65 overflow with 12 mm insect-proof mesh screened and directed away from the tank. All piping and fittings to be uPVC or stainless steel with stainless steel bolts and EPDM/food-grade gaskets. Installation to include on-site assembly, watertight sealing, hydrostatic testing per compartment (24 hours, no leakage), disinfection and first-fill procedure, drainage channel around slab, and labeling "POTABLE WATER – FIRE & DOMESTIC SUPPLY" in English and Arabic. Provide manufacturer’s certificates, test reports, and O&M manuals. № 1.00 0.00
1.1.3 Ditto Item 1.1.2 but with total effective capacity of 8,000 liters (8 m³) serving non-potable toilet wash purposes (hand washing), with DN50 PN16 inlet, DN50 PN16 outlet, DN50 drain, and DN65 overflow connections, installed on a reinforced concrete slab raised 500 mm above NGL for flood protection, and labeled "NON-POTABLE WATER – TOILET WASH" in English and Arabic. set 1.00 0.00
1.1.4 Elevated Water Tank (250 Liters) – Supply, install, and commission one food-grade polyethylene elevated water tank, nominal capacity 250 liters, conforming to ISO 4422. Include structural support as shown in the detail structural drawing, float valve or level sensor (adjustable high/low setpoints), overflow pipe (DN 25) with screen,chlorination pipe DN32, drain plug, lockable lid, outlet strainer (1 mm mesh), and DN 25 /DN32 gate valve for isolation. Mounting height: 2.5 m above NGL. № 2.00 0.00
1.1.5 Supply, install, test, and commission a complete centrifugal pump set (twin) for water transfer duty from GRP tank to elevated water tanks (EWTs), fully functional system including all auxiliary components: centrifugal pump complete with electric motor (0.25 kW, 0.33 HP, 380/400V, 3-phase, 50 Hz), base frame, coupling guard, anti-vibration mountings, suction and discharge flanges, pressure gauge, priming plug, drain plug, and all necessary fittings. Pump suitable for pumping potable water at 60 L/min flow rate and 4.27 m total dynamic head (worst-case condition: Tank 1 isolated, full flow to Tank 2) as calculated in the hydraulic design. Provide Variable Frequency Drive (VFD) panel complete with inverter drive, PLC controller with PID control logic, digital display, manual/auto selector switch, emergency stop button, phase monitoring relay, overload protection, short circuit protection, and all necessary control wiring, VFD rated for 0.25 kW motor and IP54 enclosure. Provide ultrasonic level sensors for both elevated water tanks complete with 4-20 mA output, IP67 enclosure, mounting bracket, cable gland, and all necessary accessories (range: 0-1.0 m) with "Highest Level Dominant" control logic per API 2350. Provide pump suction pipe assembly with strainer complete with foot valve, suction strainer, flexible coupling, isolation valve, and all necessary fittings. Provide pump discharge pipe assembly complete with non-return valve (check valve), gate valve, pressure relief valve, pressure gauge with siphon and isolation cock, flexible coupling, and all necessary fittings. Provide pressure switch for pump control and protection complete with adjustable set points, NEMA 4 enclosure, and all necessary accessories. Provide control panel enclosure IP54 rated complete with main isolator switch, contactors, overload relays, fuses, indicator lamps, push buttons, terminal blocks, wiring duct, and all necessary internal wiring. Provide cable and wiring from control panel to pump, VFD, level sensors (for both EWTs), and power supply complete with armored cables, control cables, cable trays, conduits, glands, lugs, and all necessary accessories. Reference pump brand: PEDROLLO CP 100 or equivalent approved brand. № 2.00 0.00
1.1.6 High-Density Polyethylene (HDPE) pipe, PN10, SDR 17, black with blue stripes, complete with all necessary fittings, elbow, T connections,joints, and accessories for a fully functional water supply system. Pipe material shall comply with ISO 4427 / BS EN 12201. The unit price shall also consider Isolation/balancing gate valves, DN40/DN32/dn25, flanged ends, PN16, ductile iron body, complete with handwheel, gland packing, and all necessary accessories, air release valve, pressure release valve, washout connection at DN40 pipe.
HDPE pipe DN40 PN10 lm 50.00 0.00
HDPE pipe DN32 PN10 lm 24.00 0.00
1.1.7 Supply and installation of Dry Latrine Squatting Pan – Ordinary Type Heavy-duty vitreous china or FRP pan, no water seal, shallow profile with anti-splash lip, drop hole min. 180mm with pipe connection to the pit as shown on the drawing. Includes fixing to concrete slab. No water supply connection." № 10.00 0.00
1.1.8 Supply and installation of Dry Latrine Squatting Pan – PWD Type Accessible design for persons with disabilities. Heavy-duty FRP or china with raised footrests, pan rim height ≤200mm from floor. Includes stainless steel grab bars (wall-mounted, vertical & horizontal). Drop hole min. 200mm with pipe connection to pit as shown on the drawing. No water supply connection." № 2.00 0.00
Total Carried to summary USD 0.00
2 WASTE WATER DRAINAGE SYSTEMS
2.1 Pit Latrine Ventilation Pipe (DN 100) – Supply, install, and commission one uPVC ventilation pipe, DN 100 mm (4 inch), conforming to ISO 1452-1, including: pipe extending from 300 mm above pit floor to 1.0 m above highest roof peak, solvent welded joints, galvanized brackets at 2 m maximum intervals, weatherproof cowl (turbo vent or 180° bend with bird screen), stainless steel insect mesh (12 mm aperture) at top, and fly-proof mesh (2 mm aperture) at pit entry. № 4.00 0.00
2.1.2 Handwashing Station (Standard) – Supply, install, and commission one handwashing station comprising: concrete basin (2800×400×200 mm), twelve (12)(six (6) on each side) lever-operated chrome-plated brass tap, two liquid soap dispenser (500 mL), supply piping PPR and uPVC drainage piping to soak away pit. set 2.00 0.00
2.1.3 Dito No 2.1.2 but for drinking water fetching and with six(6) faucet at one side only. set 1.00 0.00
2.1.4 Soak Pit – Supply, excavate, construct, and commission one soak pit for handwashing station drainage, including excavation, stone/gravel filling, perforated pipe inlet, geotextile fabric lining, and covered top with inspection port. Dimensions as per standard design. set 3.00 0.00
2.1.5 Oil/Grease Interceptor (Concrete/Masonry Construction) Supply, construction, and installation of a reinforced concrete or masonry gravity grease interceptor for pre-treatment of greywater from handwashing basins prior to discharge to the soak-away pit. Works include excavation to required depth, installation of a 100-liter minimum capacity two-compartment interceptor constructed of precast or cast-in-place reinforced concrete (minimum 150 mm thick walls) or brick/block masonry laid in Portland cement mortar (minimum 125 mm thick walls) with waterproofed interior surface to ensure watertightness . The interceptor shall include: (i) an inlet pipe with a removable coarse screening basket or silt trap for capturing solids and food debris ; (ii) a baffle wall or vertical partition with a lower communication opening to allow gravity separation based on the density difference between water and grease/oil ; (iii) an outlet pipe with a T-shaped or baffled fitting to retain floating grease; (iv) a removable, lockable cast iron or reinforced concrete cover (minimum 400 mm diameter) with access for inspection, cleaning, and maintenance ; and (v) a manhole or access step for safe entry during maintenance . The rate shall include all labour, materials, tools, excavation, backfill, compaction, concrete works, reinforcement, formwork, waterproofing, pipe connections (inlet and outlet), cover, and testing for watertightness . Construction shall comply with WaterAid Technical Guidelines, Sphere Handbook (2018), and relevant IPC provisions for grease interceptors. ls 2.00 0.00
2.1.6 Infiltration Test for Soak-Away Design Carrying out of field infiltration (percolation) test at proposed soak-away pit location to determine site-specific soil infiltration rate for the design of greywater disposal system. Works include excavation of one trial pit (minimum 0.5m × 0.5m × 0.5m), saturation of the pit, measurement of water level drop over a minimum period of 4 hours, calculation of infiltration rate (mm/hr or L/m²/day), and production of a signed test report with results and recommendations for soak-away sizing. The test shall be carried out in accordance with WaterAid Technical Guidelines and Sphere Handbook (2018) standards. The rate shall include all labour, tools, water for testing, site supervision, and report preparation. ls 2.00 0.00
Total Carried to summary USD 0.00
3 ROOF RAIN WATER DOWNPIPING SYSTEM
3.1 Rainwater Downpipe DN 80 (Toilet Block) – Supply, install, test, and commission one uPVC rainwater downpipe, DN 80 mm nominal diameter, conforming to ISO 1452-1 or AS/NZS 1260, minimum wall thickness 2.0 mm. Include stainless steel leaf guard (5 mm mesh) at roof inlet, galvanized pipe brackets (vertical spacing 1.8 m maximum, horizontal spacing 1.0 m maximum), UV-reflective light-colored oil paint coating (white/light grey) conforming to ISO 4892-2 on all exposed sections, and discharge splash block at base. Complete from roof outlet to ditch/splash block. ml 20.00 0.00
Total Carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.7.1-Water Reservior Plat form & Pump Control Switch Room-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A 0.00
B. SUPER-STRUCTURE
1 BLOCK WORK USD 0.00
2 ROOFING USD 0.00
3 METAL WORK USD 0.00
4 STEEL STRUCTURE USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No additional allowance for working space to be considered for measurement. The site clearing area shall be the net built-up area including aprons, open ditch, entrance step and ramp. m2 74.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for the ground floor from the Average Natural Ground Floor Level (A.N.G.F.L.) to a depth not exceeding 150 cm. The volume of excavation shall be measured only over the net built-up area of the building footprint, excluding aprons, open ditches, and ramps. Working allowance: An additional 0.50 m width on each side of the excavation shall be included to allow for proper working space. Reference level (A.N.G.F.L.): The A.N.G.F.L. is defined as the average of the topographic ground levels taken at the building footprint prior to any excavation works, reduced by 20 cm to account for above work item site clearing. m3 23.00 0.00
1.3 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level. Note: measurement shall include 150 cm working space in each side for trench excavation. m3 21.00 0.00
1.4 Back fill under hard core and around the building with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 12.00 0.00
1.5 Back fill around masonry wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 8.00 0.00
1.6 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material. Disposal shall be measured as the net volume arising from the void created by the excavation, less excavated material backfill, filled and wheel spread within site or left stockpiled. m3 58.80 0.00
1.7 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 34.00 0.00
1.8 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone.only under concrete channel. m2 40.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately.
2.1 5 cm thick lean concrete in grade/class C-5 concrete, minimum cement content of 150 kg/m3 :
A. Under ground floor slab m2 21.00 0.00
B. Under masonry foundation wall m2 41.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
A. In grade beam m3 2.05 0.00
B. In 10 cm thick slab m2 40.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
To grade beam m2 21.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
A. For grade beam
Dia 8 mm deformed bar Kg 129.00 0.00
Dia 12 mm deformed bar Kg 205.00 0.00
B. For slab on grade
Dia 8 mm deformed bar Kg 159.00 0.00
Total carried to summary USD 0.00
3.1 50 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 21.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
1.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for pointing. price shall include pointing m2 42.00 0.00
Total carried to summary USD 0.00
2.1 Supply and fix approved standard pre-painted 0.35mm thick corrugated iron sheet (C.I.S.) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). m2 14.00 0.00
Total carried to summary USD 0.00
3.1 Double-leaf metal door constructed from 40×40×3 mm RHS steel for vertical and horizontal framing, fully welded and braced with similar RHS sections as shown in the Architectural drawings. Door to be infilled with galvanized steel wire mesh 2.5 mm dia. at 25 mm c/c, welded to frame. Include all necessary welding, surface preparation, one coat of primer, and two coats of synthetic enamel paint to all steel surfaces. All work to conform to detailed drawings and relevant standards.
A. Door D1 size 100 x 100 cm. no 1.00 0.00
B. Door D2 size 170 x 150 cm. no 1.00 0.00
3.2 Wire mesh covering for pump control switch side walls made of galvanized steel wire mesh 2.5 mm diameter, spaced at 25 mm c/c, fixed securely to RHS structural frame using appropriate clamps or welding as shown on the drawings. The work includes cutting, fitting, welding (where required), surface preparation, one coat of metal primer, and two coats of synthetic enamel paint on all steel members. All materials and workmanship shall comply with the relevant standards and detailed drawings. m2 9.68 0.00
Total carried to summary USD 0.00
4 STEEL STRUCTURE
4.1 Supply, fabricate, assemble, and erect steel structures using RHS and CHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel Structure Column
Steel structure columns are vertical primary load-bearing members, transferring axial loads (and occasionally bending) from trusses to foundations. Since columns are in direct contact with water during cleaning, apply bituminous damp-proof paint at the column base up to a height of 300 mm (30 cm) to prevent corrosion and moisture penetration.
A.1 steel structure column using two RHS sections, 60 × 60 × 3 mm. not welded part single unit. kg 86.00 0.00
B. Steel Structure Column Beam
The beam shall be welded column to column just below the top plate level where truss and column connected. At the end of the beam where there is no steel column. it connected with the existing building it will be fixed with plate at the concrete column/tie beam
B.1 RHS 60 x 60 x 3mm beam kg 195.00 0.00
C. Steel rafter
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards.
C.1 RHS 80 x 60 x 3mm rafter kg 69.00 0.00
D. RHS Purlins 0.00
D.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 100 x 40 x 3mm L= 60mm angle iron. Price include angle iron. kg 106.00 0.00
4.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate size 150 x 150 x 8mm with 4 dia.18 slotted holes for dia. 16 J-bolt No 8.00 0.00
A.2 Metal plate 40x200x3 welded to truss and bolted to angle iron-2 ∅8mm bolt to connect angle iron to metal plate No 32.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.7.2.1-Pump Control Switch Room-1-Electrical
ITEM DESCRIPTION UNIT QTY RATE TOTAL
Supply and install:-
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Factory assembled and tested surface-mounted Sub distribution Board, SDB-PH1 in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories, and consisting: 0.00
1pc main MCB of 20A, 2P, Icu=10KA, coupled with RCD ,300mA Type S/ Time delayed 0.00
2pcs RCBO of 16A, 2P, Icu=6KA , 30mA 0.00
1pcs MCB of 10A, 2P, Icu=6KA
2pcs MCB of 16A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer 0.00
with 25% reserve space and busbar of 63A, 3ph+N No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 1.00 0.00
1.3 Light Fittings and Lamps 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 2.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Single pole Switch water proof IP44 No 1.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 2.00 0.00
1.6 Power outlet points.
1.6.1 16A/1P power outlets point for domestic water pump fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 1.00 0.00
1.6.2 100A/3P power outlets point for Fire Pump set control panel fed through XLPE insulated fire rated conductors of 3x35/16+16 mm² inside PVC conduits of 100mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 1.00 0.00
1.7 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.7.1 16A ,1ph ,230V 2p+e socket out let water proof IP44 No 2.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.7.2.2-Pump Control Switch Room-2-Electrical
ITEM DESCRIPTION UNIT QTY RATE TOTAL
Supply and install:-
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Factory assembled and tested surface-mounted Sub distribution Board, SDB-PH2 in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories, and consisting: 0.00
1pc main MCB of 20A, 2P, Icu=10KA, coupled with RCD ,300mA Type S/ Time delayed 0.00
2pcs RCBO of 16A, 2P, Icu=6KA , 30mA
1pcs MCB of 10A, 2P, Icu=6KA 0.00
2pcs MCB of 16A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A/1P+N. No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 1.00 0.00
1.3 Light Fittings and Lamps 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 2.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Single pole Switch water proof IP44 No 1.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 2.00 0.00
1.6 Power outlet points.
1.6.1 16A/1P power outlets point for domestic water pump fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 1.00 0.00
1.7 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.7.1 16A ,2P,230V 2p+e socket out let water proof IP44 No 2.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.8-Solid Waste Collection-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A 0.00
B. SUPER-STRUCTURE
1 BLOCK WORK USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No additional allowance for working space to be considered for measurement. The site clearing area shall be the net built-up area including aprons, open ditch, entrance step and ramp. m2 30.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for the ground floor from the Average Natural Ground Floor Level (A.N.G.F.L.) to a depth not exceeding 150 cm. The volume of excavation shall be measured only over the net built-up area of the building footprint, excluding aprons, open ditches, and ramps. Working allowance: An additional 0.50 m width on each side of the excavation shall be included to allow for proper working space. Reference level (A.N.G.F.L.): The A.N.G.F.L. is defined as the average of the topographic ground levels taken at the building footprint prior to any excavation works, reduced by 20 cm to account for above work item site clearing. m3 9.00 0.00
1.3 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level. Note: measurement shall include 150 cm working space in each side for trench excavation. m3 9.00 0.00
1.4 Back fill under hard core and around the building with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 8.00 0.00
1.5 Back fill around masonry wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 3.00 0.00
1.6 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material. Disposal shall be measured as the net volume arising from the void created by the excavation, less excavated material backfill, filled and wheel spread within site or left stockpiled. m3 24.00 0.00
1.7 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 13.00 0.00
1.8 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone.only under concrete channel. m2 11.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately.
2.1 5 cm thick lean concrete in grade/class C-5 concrete, minimum cement content of 150 kg/m3 :
A. Under ground floor slab m2 11.00 0.00
B. Under masonry foundation wall m2 9.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
A. In grade beam m3 1.10 0.00
B. In 10 cm thick slab m2 11.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
To grade beam m2 9.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
Dia 8 mm deformed bar Kg 33.00 0.00
Dia 12 mm deformed bar Kg 60.00 0.00
B. For slab on grade
Dia 8 mm deformed bar Kg 47.00 0.00
Total carried to summary USD 0.00
3.1 50 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 8.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
1.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for pointing. price shall include pointing & concrete copping on top of the short wall m2 40.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.9-Site Works-Civil
1 Gravel Finish- Compound Surface USD 0.00
2 Perimeter Fence with Gate USD 0.00
3 Landscaping Work USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 Interlocking Tile for Walk & Car way way
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net pavment area including curbstone. m2 2,358.20 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes curb stone. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 1,179.10 0.00
1.3 Load and cart away surplus excavated material to a suitable damping area allowed by the municipality not more than 5km from the site. m3 1,650.74 0.00
1.4 Selected fill to 95% MDD, including watering and rolling as shown the drawing m3 1,179.10 0.00
1.5 Supply and place crushed stone base course (C-4) 100 mm thick, including spreading, watering, and compaction to 95% MDD. m3 235.82 0.00
1.6 Supply and lay clean coarse sand bedding layer, 30–50 mm thick, leveled and compacted. m3 117.91 0.00
1.7 Supply and lay hand-dressed natural basalt/granite cobblestones (approx. 150×150×150 mm), tightly packed with joints filled with sand or cement-sand slurry as directed by the Engineer. m2 2,358.20 0.00
1.8 Edge restraint using concrete curb (150×400 mm) including excavation, formwork, placing, and finishing. ml 622.00 0.00
1.9 Pointing and final compaction of cobblestone surface including sweeping fine sand into joints and watering. m2 2,358.20 0.00
1.10 Supply, fabricate and fix steel bollards with steel chains for physical protection at conflict points, as follows: Bollards: Fabricated from 100 mm diameter galvanized steel pipe (CHS) 900 mm height above ground level fixed to 300 x 300 x 300 mass concrete foundation anchor with angle iron as shown on the detail drawing the bollard specing shall be c/c 1000mm. the space between the bollards shall be fixed with chain made of Heavy-duty 6 mm diameter steel chain, galvanized finish, connected to bollards using industrial-grade eye-bolts/hooks at the specified height. Fabrication, welding, installation, and fixing strictly as per drawings and engineer’s instructions. Price includes all materials (steel sections, chains, anchor bolts), excavation, concrete foundation, welding, surface preparation (grinding, de-scaling), one coat of anti-rust primer, two coats of exterior-grade metal paint, transport to site, and all necessary labor, tools, and equipment to complete the installation. Ml 159.00 0.00
Total Carried to Summary (USD) 0.00
2.1 Supply, fabricate, and install galvanized steel wire mesh perimeter fence comprising 40 × 40 × 2 mm angle iron vertical posts spaced at 2800 mm centers, fixed in concrete pad foundations, with top, middle and bottom horizontal rails (30 × 30 × 2 mm angle iron). The fence infill to be galvanized steel wire mesh (Ø 2.5 mm, 50 × 50 mm grid) securely fixed to the frame. The work also include three rows of barbed wire for security. The rate shall include excavation, concrete works, anti-rust treatment, metal painting,fabricated from similar materials, complete with all accessories and incidental work to complete the work, in accordance with the detail drawing,specifications and Engineer’s instructions. ml 366.00 0.00
2.2 Supply, manufacture & errect main entrance and exit metal door. Price shall include preparation and all necessary incidenatal work to complete the work. Alla are as per the Architectural and structural detail drawing. The work also include gate concrete post as shown in the detail structural drawing No 4.00 0.00
Total Carried to Summary (USD) 0.00
3 LANDSCAPING WORKS
3.1 Excavate the top soil to an average thickness of 20cm.for greenery part m² 761.00 0.00
3.2 Bulk excavation to remove the ordinary soil depending up on the actual level but not exceeding 50cm from reduced ground level. m3 380.50 0.00
3.3 Load and cart away surplus excavated material to a suitable damping area allowed by the municipality not more than 5km from the site. m3 532.70 0.00
3.4 Supply, well decomposed animal manure or equivalent organic material to be mixed with the topsoil averagely 300mm and to use in backfilling of planting pits.Price shall include all the necessary works to complete the work. Provide 1kg sample and details of supplier With quotation for Landscape Architect’s approval. m³ 228.30 0.00
PLANTING INSTALLATION OF GROUND COVERS:
3.5 Provide and plant grass as selected by the landscape architect. price includes gras as per the detail Architectural drawing. m2 543.00 0.00
3.6 Maintenance of lawn , grass, trees, shrubs, seasonal flower bed, other plantation and horticultural operations for weeding, watering, spreading of manure, good earth , fertilizers, spray of insecticides, fungicides, hoeing, pruning of tree/shrubs/hedge plants grassing garden swords, anti-termite treatment. Rates to include cost of material, all labor, tools & tackles, cost of manure, earth, fertilizer, pesticides etc. and also providing complete arrangement at site/sites for grass cutting by brand new power run lawn mower with skilled machine man & labor, diesel, lubricant to ensure mowing on barns and by manual labor through garden sward on the slop of under pass of the grass at least 3 times / month complete Month 2.00 0.00
Total Carried to Summary (USD) 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.10-Site Works-Electrical
ITEM DESCRIPTION UNIT QTY RATE TOTAL
1 Manhole for Electrical Systems
1.1 Construct rectangular double red burnt brick electrical manholes of internal dimensions 800mm × 800mm × 600mm (MH-2) in accordance with the detail drawings and specifications. The manhole shall comprise 250mm thick double red burnt brick masonry walls, internally plastered with cement-sand mortar, a 100mm thick reinforced concrete base slab, and a 100mm thick removable reinforced concrete cover slab complete with flush-type cover, all as approved by the Engineer. The rate shall include excavation to the required depth, disposal/cart-away of surplus excavated material, back-filling and compaction around the structure, supply and placement of concrete, reinforcement, form-work, brick masonry, plastering, curing, and all associated civil works, labor, materials, tools, and incidentals necessary for the complete and proper construction and functioning of the electrical manhole system. Set 3.00 0.00
1.2 uPVC Pipes and Ducts
1.2.1 100mm diameter uPVC m 60.00 0.00
1.2.2 50mm diameter uPVC m 500.00 0.00
1.3 Earth Network (Grounding System)
1.3.1 Grounding pit 600x600x700mm with top cover inscribed "Grounding pit" as per the detail drawing. (MH-1) No 6.00 0.00
1.3.2 Bare ground connecting copper cable of 1x70sq.mm ml 450.00 0.00
1.3.3 Earthing electrode diameter 20mm and length 3000mm 0.00
copper rode 0.00
Note: If the earth resistance is more than 10 ohms 0.00
add additional electrode spaced at length of 0.00
the electrode (spaced at a minimum of 5m apart) No 6.00 0.00
1.3.4 Equipotential Bonding - Supply and installation of complete equipotential bonding system with appropriate size equiptential earth bar to be palce near to the main board as shown in the drawing, for all applicable exposed and extraneous metallic parts, including structural steelwork, metallic water pipes, HVAC/MEP services, and other metallic services, using appropriately sized copper bonding conductors, bonding clamps, terminals, connectors, and all necessary accessories, connected to the Main Earth Bar in accordance with the design, applicable standards, and drawings. LS 1.00 0.00
1.4 DISTRIBUTION BOARDS 0.00
1.4.1 Factory assembled and tested surface-mounted Central main distribution Board, CMDB in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories, and consisting:
1pc main MCCB of 160A, 3P+N/2, adjustable magnetic (short-circuit) protection only, Icu=16KA
1pcs MCCB of 100A, 3P+N/2, adjustable magnetic (short-circuit) protection only, thermal/overload protection disabled or excluded, suitable for fire pump feeder, Icu=10KA
1pcs MCCB of 100A, 3P+N/2, Icu=16KA
1Pc of surge arrestor of 40KA Type 1 , coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
3 pcs current meters of 160/5A with 6A fuse
1 pc Volt meter of 500V with selector switch and 6A fuse
1 pc frequency meter
with 25% reserve space and busbar of 200A/3ph+N. No 1.00 0.00
1.4.2 Factory-assembled and tested surface-mounted main distribution Board (MDB) in a sheet steel enclosure with a lockable door, including all necessary fixing and connecting accessories, and consisting:
1pc main MCCB of 100A, 3P+N/2 , Icu=10KA coupled with 500mA, RCD. Type S/ Time delayed
1pcs MCB of 40A, 4P, Icu=10KA
1pcs MCB of 32A, 4P , Icu=10KA
1pcs MCB of 25A, 4P , Icu=10KA
2pcs MCB of 20A, 2P, Icu=6KA
2pcs MCB of 16A, 2P Icu=6KA
2pcs MCB of 25A, 4P (spare) Icu=10KA
with 25% reserve space and busbar of 125A/3ph+N. No 1.00 0.00
1.5 Feeder Cables and PVC pipes 0.00
XLPE Insulated PVC Sheathed 0.6/1KV power cable (IEC 60502-1), or approved equivalent to be drawn inside riser shaft or PVC conduit (measured elsewhere, tentative) and of:- 0.00
Cable sizes include: 0.00 0.00
1.5.1 3X95/50+50 mm2 From TX to CMDB m 10.00 0.00
1.5.3 3X35/16 mm2 CMDB to Firefighting CP ( Fire rated cable) m 45.00 0.00
1.5.4 4x16 mm2 From MDB to SDB - VM m 30.00 0.00
1.5.5 4x10 mm2 From MDB to SDB - CM, m 180.00 0.00
1.5.6 4x6 mm2 From MDB to SDB-MPH m 150.00 0.00
1.5.7 3x4 mm2 From MDB to SDB SR1, m 10.00 0.00
1.5.8 3x4 mm2 From SDB-MPH to UPS, from UPS to SDB - UPS m 20.00
1.5.9 2x4 mm2 From MDB to SDB -PH1, From SDB-MPH to SDB-PH2 & SDB-SR2 m 200.00 0.00
1.5.10 3x2.5 mm2 From SDB -PH-1 to SDB-TO-1, From SDB -PH-2 to SDB-TO-2 m 30.00 0.00
1.5.11 1x16mm2 earthing cable from Fire pump CP to Earth rode, From SDB-VM to Earth rode m 20.00
1.5.12 1x10 mm2 from SDB-CM to Earth rode, m 15.00
1.5.13 1x6mm2 earthing cable From SDB-MPH to Earth rod m 15.00
1.5.14 1x4mm2 earthing cable From SDB-PH1, SDB-PH2, SDB-SR2 to Earth rode m 35.00
1.6 Light Fittings and Lamps 0.00
. Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing. IEC 60969 standards or equivalent and type approved 0.00
1.6.SL1 LED Solar Street Lights for Outdoor, at least 15000 Lumens DA high-brightness, all-in-one solar street light for perimeter lighting, powered by sunlight with no electricity costs. Key Specifications Brightness: ≥15,000 lumens (bright as daylight) Light Type: LED (SMD 2835 or CREE 3030 chips) Color: Cool white (6000K–6500K) Solar Panel: 120-watt monocrystalline (charges in 6 hours) Battery: LiFePO4, ≥7-year lifespan, 3-day backup capacity. Operation: Dusk-to-dawn (auto on/off with daylight sensor) Motion sensor (full brightness on movement, dims to save energy) Remote control (adjust brightness, set timers) Weatherproof: IP65 (waterproof, dustproof, works in rain or heat) Material: Aluminium housing, tempered glass cover Runtime: 11 hours after 6-hour charge; up to 18 hours in dim mode Installation: Pole or wall mount (6ms height), no wiring needed Durability: Works in -22°F to 140°F; 50,000+ hour lifespan Warranty: 3–5 years, The luminaire shall incorporate an integrated surge protection device (SPD), minimum Type II, suitable for outdoor LED lighting applications, with a nominal discharge current (In) of at least 10 kA and a maximum discharge current (Imax) of at least 20 kA. Complete with all accessories necessary for installation and commissioning. No 21.00 0.00
1.6.2 Supply, install, test, and commission a 6 m high hot-dip galvanized octagonal steel pole, complete with luminaire outreach arm, suitable for supporting an integrated solar LED street lighting system including battery box at 5m height, and all associated mounting accessories. The pole shall have a base diameter of 140 mm and a top diameter of 60 mm, and shall be supplied complete with base plate, foundation anchor bolts, templates, and all necessary fittings. The pole shall be designed and manufactured in accordance with EN 40-3-1 and rated for a reference wind velocity of 30 m/s (108 km/h). Complete concrete pole foundation/pad,including setting out, excavation, disposal of surplus material, preparation and compaction of formation, selected backfill and compaction, blinding concrete where required, reinforced concrete, reinforcement steel, formwork, anchor bolts, plate nuts, washers, templates and non-shrink grout; installation, alignment and commissioning of pole, PV panel and luminaire; testing of PV charging, battery operation and lighting performance; and all labor, materials, equipment, transportation, tools and incidentals necessary to provide a complete and operational solar PV lighting system in accordance with the approved drawings and specification Complete in accordance with the drawings and technical specifications. No 21.00 0.00
1.7 Lightning Arrester System
(Eritech or Equivalent)
Shall include all metalic structures in the network with appropriate welding (ventpipes,ducts ,GIS roof & structures, solar PV panels, e.t.c)
1.7.1 Early Streamer Emmision(ESE) Protector SI 60 with mounting mast of H=2.0m and all necessary connecting acessories. No 2.00 0.00
1.7.2 25x3mm copper tape with all necessary roof connecting accessories m 60.00 0.00
Down conductor 0.00
1.7.3 25 x 3mm insulated copper tape with vertical supportings every 0.3m to the wall & all the necessary accessories coordinate the routing of down conductors with the building external skin and architectural features. ml 30.00 0.00
1.7.4 Lightening Event counter to be installed on the down conductor to count number of lightening strikes. No 4.00 0.00
1.7.5 Test point (junction box) with all necessary connection acessories to connect the down conduction with the earthing bare copper wire. at least 1.5m above floor finish. No 4.00 0.00
1.7.6 Prefabricated Crowsfeet 25x3mm tinned coper tape. In complienc with IEC-EN 62561-2, with L1=1000mm and L2= 3000mm No 6.00 0.00
1.7.7 50 x 50 x 50 cm test pit with top cover inscribed "Test pit" as per the detail drawing( MH-3) No 6.00 0.00
1.7.8 1 x 70 sq.mm bare copper wire ml 20.00 0.00
1.7.9 Earthing electrode Diameter 16mm & 1500mm long copper rod No 6.00 0.00
1.9 FIRE ALARM SYSTEM 0.00
1.9.1 16A/2PPower outlet point for fire alarm control panel and repeater panel , fed through fire rated cable of 3x2.5mm2 inside and including rigid PVC conduits of 19mm diameter including junction boxes with covers insulating screw cap connectors complete. No 2.00 0.00
1.9.2 RS-485 communication cable to connect FACP and Repeater panel. ml 170.00 0.00
1.9.3 Conventional Fire alarm Control Panel, Minimum of 3 zones Complete with power supply & battery backup, and RS-485 communication port for repeater panel. No 1.00 0.00
1.9.4 Conventional Fire alarm repeater Panel, 3 zones Complete with power supply & battery backup and RS-485 communication port. No 1.00 0.00
1.9.5 Smoke detector; with Flash Scan and Detector Base, Complete No 12.00 0.00
1.9.6 Fire alarm sounder strobe (RED), for outdoor use IP66 No 6.00 0.00
1.9.7 Outdoor manual call point complete with a lockable, transparent anti-vandal protective cover with local audible warning on cover lifting. The manual call point shall be resettable type, suitable for outdoor installation, minimum IP66 and IK10, UV-resistant, corrosion-resistant, and compatible with the fire alarm system. The unit shall comply with EN 54-11, and shall be complete with weatherproof mounting box, fixing accessories. No 12.00 0.00
1.9.8 Flush Mounted Fire Alarm Points (smock detectors, manual call points, sounders, and sounder beacons) fed in 2 x 2.5sq. mm fire-resistant, low-smoke, zero-halogen (FRLS/LSZH) fire alarm cable. For internal building installations, cables shall be installed in 19 mm diameter FRLS PVC conduits concealed or surface-mounted as specified. For external inter-building connections, cables shall be installed in 50 mm diameter heavy-duty uPVC conduits buried underground between blocks, complete with all necessary conduit accessories, including bends, couplings, adaptors, junction/pull boxes, warning tape, and draw wire No 30.00 0.00
1.9.9 Supply and installation of an end-of-line resistor, compatible with the specified fire alarm control panel and associated conventional detection/alarm circuits, complete with suitable enclosure/base, terminals, identification label, and all accessories required for proper termination and supervision of the circuit. Resistor value shall be as specified/ recommended by the fire alarm system manufacturer and shall be installed at the electrically final device/end of each supervised circuit. This includes testing, commissioning, and integration with the fire alarm system. No 3.00 0.00
1.10 Documentation 0.00
. Engineering, electrical installation as built drawings and O&M manuals. Qualified Set 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.11-Site Works-Sanitary
SITE DRAINAGE WORKS
1 SURFACE RAIN WATER DRAINAGE SYSTEM USD 0.00
2 GENERAL ITEMS USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 SURFACE RAIN WATER DRAINAGE SYSTEM
The rates for drainage ditches shall include full compensation for excavation, disposal of excavated material, preparation of subgrade, supply and placement of concrete (minimum 25 MPa compressive strength at 28 days) or masonry as specified, forming of trapezoidal or rectangular cross-section, installation of galvanized steel gratings where needed, construction of catch pits with debris screens, joint sealing, curing, and finishing to achieve Manning's roughness coefficient n = 0.017 for concrete ditches and n = 0.025 for masonry ditches, including all formwork, reinforcement where required, and erosion protection measures at outlets. For open ditch sections without covers, the rate per linear meter includes only the items above. For open ditch sections with integrated reinforced concrete covers at public/car way crossings, the rate per linear meter shall additionally include the supply and installation of concrete covers at locations and spacing shown on the drawings, each cover spanning the full ditch clear opening, designed for vehicle overrun loading (BS EN 124 Class B125 for car parks or D400 for carriageways as specified), including 25 mm cement mortar bedding on ditch walls, concrete grade minimum C30/37, reinforcement mesh top and bottom (minimum A142), formwork, non-slip surface finish flush to adjacent grade, galvanized lifting inserts for removal, and curing. No separate payment shall be made for excavation, backfill, disposal, bedding mortar, lifting provisions, or individual covers – the cost of covers at the indicated spacing is deemed included in the per linear meter rate for covered sections. Any gratings or covers damaged during construction shall be replaced at no additional cost.
1.1 Drainage Open Ditch – Supply, excavate, construct, and commission reinforced concrete drainage ditch, rectangular cross-section, with different internal dimensions, concrete grade minimum 25 MPa, smooth finish achieving Manning’s n = 0.017, including excavation to required depth, disposal of surplus material, formwork, reinforcement, joints (with waterstop where needed), and curing.. Provide a minimum slope of 1% or follow the natural ground slope which ever is greater
DITCH-: SIZE[mmXmm] = 600 X 600 ml 210.00 0.00
DITCH-: SIZE[mmXmm] = 200 X 350 ml 360.00 0.00
DITCH-: SIZE[mmXmm] = 400 X600 ml 100.00 0.00
1.2 Dito item No 1.1 but with integrated reinforced concrete cover at public/car way crossings – complete as specified, including all excavation, ditch lining, and concrete covers (BS EN 124 Class B125/D400 loading).
DITCH-: SIZE[mmXmm] = 600 X 600 ml 50.00 0.00
DITCH-: SIZE[mmXmm] = 200 X 350 ml 70.00 0.00
1.20 Catch Pit with Debris Screen – Supply, excavate, construct, and commission one catch pit at ditch junctions or before discharge points, including reinforced concrete construction, minimum 600×600×900 mm deep, removable heavy duty cast iron cover, stainless steel debris screen (12 mm mesh), inlet and outlet connections to adjoining ditches, and concrete base. № 6.00 0.00
Total carried to summary USD 0.00
2 GENERAL ITEMS
2.1 Allow for Testing and commissioning of the entire plumbing installation by a Chartered Mechanical Engineer and obtaining a Test Certificate (3rd party testing to approval of the Engineer) including all off-site and factory testing; inspections to demonstrate compliance with relevant standards, operating the completed installation and submitting all relevant test records and authority approval. LS 1 0.00
2.2 All sanitary fittings supplied shall be provided with a minimum 5 year warranty, issued jointly and severally by the local supplier and the manufacturer. LS 1 0.00
2.3 Allow for preparation of Operationa and Maintenance Manual including site users training for the O & M Maual of all plumbing and mechanical appliances. LS 1 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bill No.12-Signage
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 Directory Signs
Design, supply and install international standard Boy's, Girl's & PWD Toilet directional sign complete with pictogram (Girl's, Girl's & PWD toilet sign symbol) plus directional arrow that leading to the toilets. The sign shall also consist text “Boy's , Girl's & PWDToilet.” Sign shall be minimum size 300 mm × 400 mm, high quality tin: tin sign with retro design, metal tin, long-term use, not easy to damage, smooth surface, ...with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 3.00 0.00
2 Directory Signs
2.1 Supply and install main directional sign with text “To each building listed as Signage S-1 Architectural drawing with arrow, made of 3 mm thick photoluminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm for each building direction, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for outdoor mounting with weatherproof finish.Price include civil work to fix the signage post. No 1.00 0.00
2.2 Building departmet sign as the above item the text and size letter hight shall be as per the detail Ar. Signage and the name listed below.
A "Crop Market" sign fixed on the front side elevation No 1.00 0.00
B "Vegetable Market" sign fixed on the front side elevation No 1.00 0.00
C "Multi-Purpose Hall" sign fixed on the front side elevation No 1.00 0.00
D "Toilets" sign fixed on the front side elevation No 2.00 0.00
E "Security House 1 & 2" sign fixed on the front side elevation No 2.00 0.00
F "Solid Waste Collection" sign fixed on the front side elevation No 1.00 0.00
3 Room Identication Signs
Design and supply signage with room number in accordance with this specification and as directed by the Architect. The material shall be made of 3-5mm thick wall mounted Acrylic signs. The size shall be 250mm x 30mm and letter height shall be 50-70mm for room number, 25-40mm room name letters and braille and tactile characters where applicable. The color and contrast between the text and background shall be high and the color shall be consistent with the veternary clinic branding (if any) or as per the Architect approval. The topography and information shall be Room number: Bold, large font (sans serif preferred), Room function/name: Smaller font beneath the number (e.g., Room 101 – Office) and Braille/tactile lettering placed below the printed text. The signage shall be fixed to the wall at 1.4–1.5 m above floor to centerline of sign on the latch side of the door, or directly on the door if wall space is not available and it shall be fixed with secure concealed fasteners or adhesive (depending on wall/door material). The supplier shall produce and submit Mock-ups for approval before mass production. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect.
3.1 Male & female Rest rooms and with pictogram of gents, ladies and PWD No 4.00 0.00
3.2 First Aid sign as shown in the detail drawing No 4.00 0.00
4 Safety and Compliance Signs
4.1 Design, supply and install Entrance Sign in accordance with this specification and as directed by the Architect. The material shall be made of flame-retardant, impact-resistant ABS clear acrylic plate and shall comply with BS EN ISO 7010 Exit Symbol (E001) and shall have Multi-installation system: Hanging, wall or surface mounted depending on the location. The size of the letter height shall be minimum 150mm with a stroke width 19mm, color contrast to be white letters on green background and the sign shall consist text+ directional arrow that leading to entrance.The sign shall be fixed to entrance access point at 2.00–2.50 m above floor level. The supplier shall produce and submit Mock-ups for approval before mass production or procurement. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect. No 4.00 0.00
4.2 Supply and fix 3mm rigid PVC/acrylic Fire Extinguisher sign (300mm x 100mm) with 50mm high ISO-compliant white lettering on red background, including all fixings and installation. No 14.00 0.00
4.3 Supply directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. Supply and install directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. No 4.00 0.00
4.4 Supply emergency assembly point safety sign complete with standard ISO 7010 pictogram (E007: four people symbol) and text “EMERGENCY ASSEMBLY POINT.” Sign shall be fabricated from 3 mm thick photo luminescent rigid PVC or aluminum composite panel, minimum size 600 mm × 600 mm, with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 2.00 0.00
4.5 No smoking sign as per the detail Ar.drawing No 28.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.13-Day Works
1 LABOUR USD 0.00
2 MATERIAL USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
(ALL PROVISIONAL)
In accordance with the Conditions of Contract, the Contractor will be paid day work rates for extra work that cannot properly be measured and valued, and the Contractor is to insert in the space provided below the basic rates and costs of labour,materials and plant as described hereunder:-
1.1 MASON hours 1 0.00
1.2 CARPENTER hours 1 0.00
1.3 SCAFFOLDER hours 1 0.00
1.4 JOINER hours 1 0.00
1.5 PLUMBER hours 1 0.00
1.6 ELECTRICIAN hours 1 0.00
1.7 PLASTERER hours 1 0.00
1.8 PAINTER hours 1 0.00
1.9 LABOURER hours 1 0.00
TOTAL in USD 0.00
1.10 To the basic net rates of labor used for work carried out on day works, an addition 25% percent which is to include for task work and incentive schemes, tools, standing, scaffolding, supervision, insurance, transport profit and overheads.
To collection of Labour Day works 0.00
2.1 Cement Per Tonne 1 0.00
2.3 Aggregate (grade 25 - 5mm) m3 14 0.00
2.4 Steel reinforcement
(i) Mild steel bar Kg 1 0.00
(ii) High tensile bar Kg 1 0.00
2.5 Timber formwork Per SQ.M 1 0.00
2.6 Paint, Gloss Per 4 Litres 1 0.00
2.7 Paint, Emulsion Per 4 Litres 1 0.00
2.8 Mahogany Varnish Per 4 Litres 1 0.00
2.9 100mm diameter uPVC rainwater downpipe 6M Per Each 1 0.00
2.10 Ditto bends Per Each 1 0.00
2.11 Ditto offsets Per Each 1 0.00
2.12 Ditto watershoe Per Each 1 0.00
2.13 Fixing brackets Per Each 1 0.00
2.14 Fixing screws Per Packet 1 0.00
2.15 75mm thick x 375mm wide weather/throated cills Per M 1 0.00
2.16 4 mm Clear sheet glass Per SQ.M. 1 0.00
2.17 100mm long Flush bolt Per Each 1 0.00
2.18 Indicator Signage Per Each 1 0.00
2.19 400mm x 200mm x 100mm hollow concrete blocks Per 1000 1 0.00
2.20 300mm x300mm x 8mm Ceramic floor tiles Per SQ.M. 1 0.00
2.21 150mm x 150mm x 6mm white glazed wall tiles Per SQ.M. 1 0.00
2.22 25mm x 3mm earth copper tape Per M 1 0.00
2.23 35mmsq bare copper cable Per M 1 0.00
2.24 6mmsq bare copper cable Per M 1 0.00
2.25 2.5mmsq. TWE copper cable Per M 1 0.00
2.26 2.5mmsq. SC PVC-I copper cable Per M 1 0.00
2.27 4.0mmsq. SC PVC-I copper cable Per M 1 0.00
2.28 10.0mmsq. 3C PVC-SWA-PVC copper cable Per M 1 0.00
2.29 20mm diameter galvanised steel tubing 6M Per M 1 0.00
2.30 20mm diameter galvanised steel tee Per Each 1 0.00
2.31 20-15mm diameter reducer Per Each 1 0.00
2.32 110mm diameter uPVC soil pipe 6M Per Each 1 0.00
2.33 50mm ditto waste pipe 6M Per Each 1 0.00
2.34 110mm ditto single branch access Per Each 1 0.00
2.35 50mm ditto sweep tee Per Each 1 0.00
2.36 Single bowl, single drainer stainless steel sink size 2000 x 600mm Per Each 1 0.00
To Collection 0.00
2.37 To the basic nett rates of materials used for work carried out on dayworks, an addition of 25% which is to include for unloading and storing as necessary, the use of hand plant, and machinery etc. available on site, profit and overheads.
To collection of Material Day works 0.00
3.1 Portable Compressor with 2 breakers or equivalent with 1500 mm hoses and reels hours 40 0.00
3.2 Damp Truck (0.75 tonne) hours 40 0.00
3.3 Lorry seven tonne tipper hours 40 0.00
3.4 Concrete Mixer (14/10) complete for weight batch mixing hours 40 0.00
3.5 50 mm self priming centrifugal pump with hose and ancillary equipment hours 40 0.00
3.6 Concrete Vibrators hours 40 0.00
To Collection 0.00
3.7 To the basic rates of plant used for work carried out on dayworks, an addition of 25% per cent, which is to include for driver and/or attendance, fuel and consumable stores supervision, insurance, road licence,profit and overheads.
To collection of Plant Day works 0.00
Name of Signatory:
United Nations Office for Project Services
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
Tender Reference:
ENHANCING FOOD SECURITY & RESILIENCE OF RURAL COMMUNITIES (EFSR),
CONSTRUCTION WORKS FOR MODEL CROP & VEGETABLE MARKET PROJECT
BILL OF QUANTITIES (BOQ)
- Bill Nr.1 - Mobilization
- Bill Nr.2 to 12-Civil, Electrical & Sanitary Works-BoQ
- Bill Nr.13 - Day Works
NOTE: It is a MANDATORY requirement for bidders to complete and return both this excel BOQs and their respective duly signed pdf for further reference
Failure to complete all sections of the BOQ may result to automatic disqualification of your bid.
September, 2026
PREAMBLE TO BILLS OF QUANTITIES
1 Priliminary Condition
1.1 This Specification shall be read in conjunction with the Particular Technical Specifications provided under each work discipline, as well as the latest edition of the Sudan Standard Technical Specifications for Building Works, or any other internationally recognized standards commonly adopted in Sudan.
1.2 The Bill of Quantities (BoQ) shall be measured in accordance with the latest edition of the Sudan Standard Methods of Measurement for Building Works.Pro Memoria (PM): Indicates that the cost of the item is deemed to be included and distributed within other related work items in the BoQ. No separate payment will be made.Lump Sum (LS): Indicates that the item is priced as a fixed total amount, with no adjustment or variation permitted to the total price regardless of actual quantities executed.
1.3 The contractor has fully understood the scope of works by minutely having studied the drawings and Bill of Quantities with specifications, and by having visited the site. He will, on his own initiative and before the works start and in his best ability, notify the consultant of works which are not mentioned in the BoQ and/or the specifications and/or the drawings, which are necessary to execute the construction as envisioned in the drawings. Thus, after the works have started, the contractor cannot rely on incompletions in the consultants' work to make claims of any kind. Indeed, the contractor will add upon the specifications according to his own insight and professional experience. If there are works to be done which are not specified in this BoQ, it is up to the consultant to decide wether these works are variation works which need change orders, or wether these works are included in the items and their prices in the BoQ.
1.4 The contractor has to execute all works which have a direct or indirect impact on safety and availability of infrastructure (water, sewage, electricity, …) in as short a period as feasible.
1.5 The contractor will secure the structural and functional integrity of the exsiting buildings nearby the project site during construction work as well as of the building’s surroundings such as but not limited to public road, gate, lawn. He will study and execute the necessary scaffolding to support the building, in order to avoid any cracks, settlements, or crumbling. This scaffolding to support the building during the works are included in the prices given. Debris will be cart away to certified debris places in the area. In no way, debris will be stored, buried or burned on site.
1.6 After the works, the contractor will do a thorough cleaning of the construction site, this means cleaning of all excess mortars, cement bags, excess blockwork, excess tile jointing – in short any construction remnant which hinders the proper use of the house upon site hand-over.
1.7 In general the contractor will put his professional experience and craftsmanship to work, in order to get a holistically well-constructed building, to the highest and most up-to-date standards of Sudan Construction Culture.
2 Organisation of Construction Site
This includes all necessary preparations to execute the works; at least from the beginning until the end of the works; according to the best knowledge and experience of the contractor: at least conform local standards.
The objectives of the Bill of Quantities are
(a) to provide sufficient information on the quantities of Works to be performed to enable bids to be prepared efficiently and accurately; and
(b) when a Contract has been entered into, to provide a priced Bill of Quantities for use in the periodic valuation of Works executed.
In order to attain these objectives, Works have been itemized in the Bill of Quantities in sufficient detail to distinguish between the different classes of Works, or between Works of the same nature carried out in differently or in other circumstances which may give rise to different considerations of cost.
4 The Bills of Quantities for the Works comprise the following:
Preamble to Bill of Quantities
List of principal Quantities
Bill Nr. 1 Mobilization
Bill Nr. 2 - 12 Civil, Electrical Installation & Sanitary Installation
Bill Nr. 13 Day Works
5 The Contractor’s unit rates in these bills are to cover supplying of materials, taking delivery, transporting, loading and off loading inspection, storage, stacking, landing, preparation, installation including provision of all labour, requirement false work, temporary support, surface preparation and testing of the works. The rates shall include all applicable taxes and duty. The cost of testing of the materials to be used in the works unless otherwise provided is to be included in the rates of the respective Bill items.
6 Measurement for payment shall be for the complete installation and having passed all necessary tests.
7 Work shall not be executed on a Day work basis unless ordered in writing by the Consultant on approval by the Employer. The rates entered in the Day works Bill of Quantities shall apply to any quantity of Day work instructed by the Consultant. Nominal quantities have been indicated against each item to permit the extended total to be carried forward to the Grand Summary.
8 “Rates and prices shall be inserted in the rate and total columns of the Bill of Quantities in USD
9 Bills of Quantities are to be read in conjunction with the Instructions to Bidders, the Conditions of Contract Data, the Specifications and the Drawings. The quantities stated against each item in the Bills of Quantities, with the exception of those items specifically marked ‘sum’, are the estimated quantities of the Work to be executed by the Contractor in fulfillment of his obligations under the Contract.
10 The Contractor is required to check the number of the pages and should any be found to be missing or in duplicate he must inform the Engineer at once and have the same rectified.
11 No liability whatever will be admitted or claim allowed in respect of errors in the Contractor’s tender due to mistakes in the Bills of Quantities which should have been rectified in the manner described above.
12 The contractor shall not alter or otherwise qualify the text of these Bills of Quantities. Any alteration or qualification made without authority will be ignored and the text of the Bills of Quantities as printed will be adhered to.
13 Each item in the Bills of Quantities is to be priced. If any items are left un-priced it will be assumed that the value of the work described there under is elsewhere allowed for. The prices and rates to be inserted in the Bills of Quantities are to be fully inclusive of all costs and expenses which may be required for the construction of the work described, together with general risks, liabilities and obligations set forth or implied in these documents.
14 In no case will any claim for expenses incurred by the Contractor in preparation of this Tender be allowed.
15 The Contractor is solely responsible for the accurate ordering of materials in accordance with the Specifications, Drawings and Engineer’s Instructions and no claim for any loss or expense will be entertained for orders for materials based on the Bills of Quantities.
16 The quantities given in the Bills of Quantities are estimated and no claim by the Contractor for the final quantities being larger or smaller than the quantities given in the Bills of Quantities will be permitted except alows in accordance with the particular of the Conditions of Contract.
17 The term ‘provide’ or ‘supply’ used for any item shall be deemed to include transport to site, handling, storage and fixing complete, and the Bidder’s rate shall include for this.
18 The following abbreviations have been used in the Bills of Quantities:-
ml metre linear
m2 square metre
PS provisional Sum
Set Complete set of work with accessories & components
lot Complete set of work with accessories & components
PS provisional Sum
USD United States Dollar
uPVC un-plasticized poly vinyl chloride
HDPE high density polyethylene
GMS galvanized mild steel
PPE personal protective equipment
ASTM American society for testing & material
GW well-graded gravel
GP poorly-graded gravel
GM silty gravel, gravel-sand-silt mixtures
GC Clayey gravels, gravel sand-clay mixtures
SW well graded sands
SP poorly graded sands
SM silty sand, sand -silt-mixtures
SC clayey sands, sand-clay mixtures
AASHO American Association of State Highway and Transportation Officials,
ACI American Concrete Institue
RHS rectangular hollow section
PVD Physical Vapor Deposition
HCB hollow concret block
CBR california bearing ratio
MC medium curing
SDB sub distribution board
PDB pump distrbution board
20 Unless otherwise provided there are no separate measurement items for Contractual requirements. The Contractor is deemed to have included his costs for the Contractual requirement
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILIENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
ALL BILLS SUMMARY Amount in USD
1 Bill Nr.1 - Mobilization USD 0.00
2 Bill Nr.2 -Crop Market Building-
2.1 - Civil Work USD 0.00
2.2 - Electrical Installation Work USD 0.00
3 Bill Nr.3 -Vegetable Market Building-
3.1 - Civil Work USD 0.00
3.2 - Electrical Installation Work USD 0.00
3.3 - Crop & Vegetable Sanitary Installation Work USD 0.00
4 Bill Nr.4 -Multi-Purpose Hall Building-
4.1 - Civil Work USD 0.00
4.2 - Electrical Installation Work USD 0.00
4.3 - Sanitary Installation Work USD 0.00
5 Bill Nr.5 -Security/Guard House Building-
5.1 - Civil Work- For Two (2) Unit USD 0.00
5.2 - Electrical Installation Work- For Two (2) Unit USD 0.00
5.3 - Sanitary Installation Work- For Two (2) Unit USD 0.00
6 Bill Nr.6 -Toilet Building With Pit Laterin-
6.1 - Civil Work-Fot Two (2) Unit USD 0.00
6.2 - Electrical Installation Work-Fot Two (2) Unit USD 0.00
6.3 - Sanitary Installation Work-Fot Two (2) Unit USD 0.00
7 Bill Nr.7 Pump Control Swith Shed with Water Tanker Seat
7.1 - Civil Work for Two (2) Unit USD 0.00
7.2.1 - Electrical Installation Work Pump House-1 USD 0.00
7.2.2 - Electrical Installation Work Pump House-2 USD 0.00
8 Bill Nr.8 Solid Waste Collection-Civil Work USD 0.00
9 Bill Nr.9 Site Works-Civil USD 0.00
10 Bill Nr.10 Site Work-Electrical USD 0.00
11 Bill Nr.11-Site Works-Sanitary USD 0.00
12 Bill Nr.12 Signage USD 0.00
GRAND TOTAL USD 0.00
13 Bill Nr.13 - Day Works USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILIENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill Nr. 1- Mobilization
1 SIGN BOARD USD 0.00
2 SITE SUPERVISOR TRANSPORTATION USD 0.00
3 SAFTEY HARNESS & PROTECTION USD 0.00
4 SAFTEY & SECURITY OF WORKS USD 0.00
5 SHOP DRAWINGS USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 Contractor to provide a Project Identification sign size (200 cm × 200 cm), Contractor to submit shop drawing for UNOPS Engineer Approval, also 2 safety signs (120 cm x 120 cm). Safety signed to be submitted to approval of Engineers. LS 1.00 0.00
2 Site Supervisor Office & Transportation
2.1 Providing office for supervisor team completed with office Desk LS 1.00 0.00
3 Safety Harness and Protection
3.1 2 No (Minimum) Safety Harness with lanyards , 3 fire powder 6Kg fire extinguishers, and selection of gloves & safety glasses to be kept in UNOPS Office at all time, also contractor should in his price include the cost of providing all his staff and work force with suitable PPEs ( i.e. Hard Hat, Safety Boot, Dust Masks, Safety Vests and Safety Glasses) LS 1.00 0.00
4 Safety & Security of Works
4.1 Allow for providing safety and security for the Works and material as per the requirement laid under the Contract, including security lighting, lockable or open material storage areas, engaging security guards and / or any other measures as necessary. Cost shall include Road Safety awareness, and public traffic flow management during construction. In case the project intervention is inside the existing operational compound and accordingly the contractor shall make all the necessary planning on Contractor Safety, Security, and Operational Continuity Protocol ensures that construction works are performed without disrupting the existing business normal operations or compromising its safety and security. Contractors must strictly adhere to all guidelines, ensuring seamless coordination with the existing business management team & the consultant. Non-compliance may considered as a breach of the Contract. Contractor shall construct temporary fencing that separate the existing business and the construction site, safety access route and separate access. The contractor shall also indicated his methodology and work plan for the specific topics. LS 1.00 0.00
5 Shop Drawings
5.1 Allow for prepare and submit to the Engineer's Representative a complete set of Shop Drawings, as required to the specified scale(s), giving all details, as required by the Engineer's Representative, for the work executed. Submission shall be in 3 sets as hard copies, color printed on A1 size paper and 01 set of soft copies in AutoCAD compatible version in a compact disc. LS 1.00 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILIENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.1- Crop Market Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 1,706.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 853.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 685.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 251.00 0.00
1.5 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 89.00 0.00
1.6 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 1,272.00 0.00
1.7 Ditto as above item 1.5 but around isolated footing. m3 764.00 0.00
1.8 Ditto as above item 1.5 but around masonry foundation wall. m3 34.00 0.00
1.9 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 1,876.00 0.00
1.10 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 1,203.00 0.00
1.11 Supply and fix construction joint between grade beam & grade slab with 1 cm thick x 15cm wide chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance. ml 786.00 0.00
1.12 Ditto as above item 1.10 but construction joint between grade slab & grade slab where the slab area is larger. ml 125.00 0.00
1.13 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 340.00 0.00
2.1.2 Under masonry foundation wall m2 89.00 0.00
2.1.3 Under grade beam m2 109.00 0.00
2.1.4 Under slab on grade including ramp m2 1,203.00 0.00
2.1.5 Under masonry steps on grade m2 26.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 140.20 0.00
2.2.2 In foundation column. m3 26.00 0.00
2.2.3 In grade beams. m3 50.00 0.00
2.2.4 In ramp restrain beams. m3 1.20 0.00
2.2.5 In entrance steps. m3 6.20 0.00
2.2.6 In 15 cm thick ground floor slab including ramps & half part of open market. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing. m2 1,202.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 207.00 0.00
2.3.2 To foundation column m2 273.00 0.00
2.3.3 To grade beams & ramps edge m2 378.00 0.00
2.3.4 To ramp restrain beam m2 12.00 0.00
2.3.5 To entrance steps m2 80.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 8 mm deformed bar Kg 149.00 0.00
Dia 12 mm deformed bar Kg 2,577.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 1,208.00 0.00
Dia 16 mm deformed bar Kg 2,310.00 0.00
Dia 20 mm deformed bar Kg 2,269.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 1,665.00 0.00
Dia 16 mm deformed bar Kg 4,931.00 0.00
2.4.4 For ramp restrain beam
Dia 8 mm deformed bar Kg 37.00 0.00
Dia 12 mm deformed bar Kg 71.00 0.00
2.4.5 For entrance steps
Dia 8 mm deformed bar Kg 448.00 0.00
Dia 16 mm deformed bar Kg 208.00 0.00
2.4.6 For floor slab on grade, ramp slab & outdoor tratment slab
Dia 8 mm deformed bar Kg 377.00 0.00
Dia 10 mm deformed bar Kg 9,520.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 92.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 26.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 29.10 0.00
1.1.2 In intermidiate beams m3 32.50 0.00
1.1.3 In top tie beams m3 13.60 0.00
1.1.4 In internal partition wall tie beams m3 3.27 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 263.00 0.00
1.2.2 To intermidiate beams m2 314.00 0.00
1.2.3 To top tie beams m2 127.00 0.00
1.2.4 In internal partition wall tie beams m2 32.70 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 1,392.00 0.00
Dia 16 mm deformed bar Kg 636.00 0.00
Dia 20 mm deformed bar Kg 2,540.00 0.00
1.3.2 For intermidiate beam
Dia 8 mm deformed bar Kg 1,048.00 0.00
Dia 16 mm deformed bar Kg 3,281.00 0.00
1.3.3 For top tie beam
Dia 8 mm deformed bar Kg 483.00 0.00
Dia 16 mm deformed bar Kg 1,507.00 0.00
1.3.4 For tinternal partiton tie beam
Dia 8 mm deformed bar Kg 150.69 0.00
Dia 12 mm deformed bar Kg 290.38 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick. The bricks shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct both-side decorative face red burnt 20cm thick (double) brick wall, built in approved red burnt clay face bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, with exposed face brick finish on both sides complete in every respect m2 587.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 908.00 0.00
3.2 Ditto as above item 3.1 but gable side pre-painted 0.5mm thick EGA-500 wall clad fixed to RHS frame as shown in the structural drawing. m2 68.00 0.00
3.3 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet ridge cup at the roof slope direction changes. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of ridge cap: 80 cm. m.l. 32.00 0.00
3.4 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 126.00 0.00
3.5 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 63.00 0.00
Total carried to summary USD 0.00
4.1 Supply, fabricate and fix metal guard rail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 120 × 120 × 6 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 1000 mm above finished floor level; two horizontal balustrade rails CHS Ø20 × 2.5 mm welded to vertical RHS posts; top handrail CHS Ø50 × 2.5 mm welded continuously; infill: vertically spaced CHS Ø20 × 2.5 mm at c/c 100 mm between the two horizontal rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 99.50 0.00
4.2 Supply, fabricate and fix metal ramp & step handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 38.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect Pre-Engineerered structures steel as primary and secondary members & all other reuired accessories.The material standard and fabrication be according to applicable American, British or Europian codes and standards. The material shall be as per approved pre-engineered building sysem standard and shall include column, rafter & truss (Hot rolled and built up I-sections), purlin (Rectangular hollow section), Bracings (rod Bracings), Screws, high strength bolts, Machine Bolts,Anchor bolts, Plates and other accessories.
The system is designed for Corrosively Category C3 and Long Design Life (15+ years) in accordance with ISO 12944. Prefabrication Primer Apply one coat of zinc-rich epoxy primer to a dry film thickness (DFT) of 20-25 µm. shop Coating: After fabrication, clean welds and bolt holes and apply full epoxy intermediate coat to achieve a minimum total shop DFT of 75 µm
All structural steel members shall be protected with an approved, certificated; thin-film intumescent coating system to achieve a fire resistance rating of R60. The required Dry Film Thickness (DFT) for the minimum intumescent coating shall be 1200 µm
All damage to shop coatings incurred during transport and erection shall be cleaned and repaired to the original specification. After erection, apply a final coat of an approved Polyurethane (PU) Topcoat. The total system DFT for the full corrosion protection system (primer, intermediate and topcoat) shall be a minimum of 285 µm over the entire structure.
All are as per the detail structural drawing and specification.
A. Primary Structure
A.1 Supply, fabricate, deliver, and erect IPE 400 steel column , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 400mm, flage width 180mm, web thickness 8.60mm, flange thickness 13.50mm & unit weight kg/ml 66.30kg/ml kg 915.00 0.00
A.2 Supply, fabricate, deliver, and erect IPE 400 rafter , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 400mm, flage width 180mm, web thickness 8.60mm, flange thickness 13.50mm & unit weight kg/ml 66.30kg/ml kg 11,537.00 0.00
A.3 Supply, fabricate, deliver, and erect IPE 100 canopy truss , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 100mm, flage width 55mm, web thickness 4.10mm, flange thickness 5.70mm & unit weight kg/ml 8.10kg/ml kg 671.00 0.00
B. Secondary Structure
B.3 Supply, fabricate, deliver, and erect IPE 300 secondary beam , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 300mm, flage width 150mm, web thickness 7.10mm, flange thickness 10.50mm & unit weight kg/ml 42.20kg/ml kg 2,532.00 0.00
C. RHS Purlins 0.00
C.1 RHS 100 x 100 x 4mm purlin fixed to upper truss member with 100 x 100 x 3mm L= 60mm angle iron. Price include angle iron. Kg 12,913.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
D. RHS Gable side frame 0.00
D.1 RHS 30 x 30 x 3mm RHS frame for gable side EGA wall clad support Kg 387.00 0.00
A.1 IPE 400 column & concrete colomn connection plate size 560 x 360 x 20mm with 8 dia 22mm sloted holes. No 24.00 0.00
A.2 IPE 400 column & rafter connection plate size 180 x 822 x 10mm with 12 dia 18mm sloted holes. No 24.00 0.00
A.3 IPE 400 column & IPE 300 secondary beam connection plate size 200 x 155 x 10mm with 4 dia 18mm sloted holes. No 40.00 0.00
A.4 IPE 400 rafter & rafter connection plate at Apex size 180 x 844 x 10mm with 4 dia 18mm sloted holes. No 12.00 0.00
A.5 IPE 100 truss & concete wall mounted connection plate size 300 x 280 x 10mm with 8 M20 bolt sloted holes. No 48.00 0.00
A.6 Stiffner size 180-80 x 10mm No 48.00 0.00
B Bolt with nut
B.1 Anchor bolt with nut column connection with concrete column M20 grade 8.8 depth 300mm No 96.00 0.00
B.2 Anchor bolt with nut canopy truss with concrete column M20 grade 8.8 depth 450mm No 192.00 0.00
B.3 Bolt with nut for column with rafter connection M 16 grade 8.8 No 144.00 0.00
B.4 Bolt with nut for column with secondary beam connection M 16 grade 8.8 No 80.00 0.00
B.5 Bolt with nut for rafter with rafter at Apex connection M 16 grade 8.8 No 72.00 0.00
B.6 C1022 hex head Tek screw fixed to concrete beam No 56.00 0.00
C Tension Cable
Supply, fabricate and install tension cable bracing system for steel roof trusses, comprising T32 mm threaded tension rods/cables, turnbuckles, coupling nuts, paddle braces, gusset plates, suspension plates, clevises, anchor connections, bolts, nuts, washers and all necessary fittings, complete with tensioning, alignment and fixing in accordance with the structural drawing, approved shop drawings and Engineer's instructions. Ml 214.40 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply three coats of cement sand plaster (1:3) for exposed beam and column surfaces.The final coat shall be made with fine sand sieved through a 1.18 mm mesh. surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks m2 704.00 0.00
6.2 Rake out joints where required and execute pointing to stone masonry joint work using cement-sand mortar of specified mix, including cleaning joints, wetting surfaces, filling, finishing, curing, and all necessary labor, materials, tools, and incidentals, complete in accordance with the drawings and specifications. m2 52.00 0.00
6.3 Rake out joints where required and execute pointing to decorative red brick joint work using cement-sand mortar of specified mix, including cleaning joints, wetting surfaces, filling, finishing, curing, and all necessary labor, materials, tools, and incidentals, complete in accordance with the drawings and specifications. m2 1,174.00 0.00
6.4 Provide and lay 50 mm thick cement-sand screed flooring, finished with a smooth steel-trowelled surface, using cement and clean sand mixed in the specified proportion (1:3 or as specified), laid to the required levels, slopes, and falls, including surface preparation, mixing, placing, compacting, leveling, finishing, curing, and all labor, materials, tools, equipment, and incidentals necessary to complete the work in accordance with the drawings and specifications- for crop storage area. m2 444.00 0.00
6.5 Provide broom finish to freshly placed concrete carway, Pavmeny & ramp surface, including screeding, leveling, texturing the surface with a broom to produce a uniform non-slip finish, and all labor, tools, equipment, and incidentals necessary to complete the work in accordance with the specifications and Engineer's instructions. Concrete work measured separately. m2 878.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
7.1 Apply three coats of acrylic emulsion paint to exposed beam & column plastered wall surfaces. m2 704.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.2- Crop Market Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ELECTRICAL WORKS
1.1 DISTRIBUTION BOARDS 0.00
Flush-mounted sub distribution Board, SDB-CM in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1.1.1 1pc main MCB of 32A, 4P , Icu=10KA , coupled with RCD ,300mA, Type S/ Time delayed 0.00
10pcs RCBO of 16A, 2P, Icu=6KA ,30mA 0.00
6pcs MCB of 10A, 2P, Icu=6KA
2pcs MCB of 16A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A, 3ph+N No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 44.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W,4000K, 3600Lumen, CRI > 80, ceiling-mounted, polycarbonate, flicker-free, IP66, for outdoor instalation No 8.00 0.00
1.3.L2E LED battenLight: L1200mm, 30W, 3600 lumens, 4000K, CRI > 80, surface-mounted.High-impact polycarbonate housing and diffuser with minimum IP65 protection rating , & ~1000 lumens (emergency), 4000K, 90 minute operation, No 4.00 0.00
1.3.L4 LED Highbay , pendant ( truss mounted), D273,h 93mm, 100w, 13000Lumens, 6500K, CRI>80. Die-cast aluminum housing with a clear optical polycarbonate lens (IP65 / IK06 rated) and a 100° to 110° wide beam angle. Complete with integrated driver, suspension mounting hook/accessories, and hardware. No 20.00 0.00
1.3.(E) Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). IP65,IK08, 5700K, minimum 7W, autonomy 90min. Warranty: 3 years (components), 5 years (battery). No 8.00 0.00
1.3.(EX) Saftey only emergency with FLC 11SE or approved equivallent illuminated signage system shall be installed to give information with standard dimensions information displays and illumination level with double or single faces. The display consisting of symbols, text or figures supported with direction which will indicate EXIT, toilets (lady and gentlemen), staircases and floor level will be placed as indicated on the drawings throughout building for the convenience of the public and workers .The symbols, text or figures shall be choices of the client or engineer and shall be appropriate enough to describe the room, areas, services and all safety directions it should have emergency battery for at least 90min. No 4.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Flush-mounted thumbler switch in sheet steel enclosure with lockable door with 6pcs of 16A/1Ph two way tumbler switchs including all necessary fixing and connecting accessories No 2.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 30.00 0.00
1.6 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.6.1 16A ,1ph ,230V 2p+e Doublesocket outlet No 18.00 0.00
1.6.2 16A ,2P,230V 2p+e Doublesocket out let water proof for outdoor installation IP44. No 12.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.3.1- Vegetable Market Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 1,706.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 853.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 615.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 226.00 0.00
1.4 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 87.00 0.00
1.5 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 1,274.00 0.00
1.6 Ditto as above item 1.5 but around isolated footing. m3 680.00 0.00
1.7 Ditto as above item 1.5 but around masonry foundation wall. m3 33.00 0.00
1.8 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 1,895.00 0.00
1.9 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 1,213.00 0.00
1.10 Supply and fix construction joint between grade beam & grade slab with 1 cm thick x 15cm wide chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance. ml 645.00 0.00
1.11 Ditto as above item 1.10 but construction joint between grade slab & grade slab where the slab area is larger. ml 210.00 0.00
1.12 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 308.00 0.00
2.1.2 Under masonry foundation wall m2 79.00 0.00
2.1.3 Under grade beam m2 76.00 0.00
2.1.4 Under slab on grade including ramp m2 1,213.00 0.00
2.1.5 Under masonry steps on grade m2 26.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 132.00 0.00
2.2.2 In foundation column. m3 23.00 0.00
2.2.3 In grade beams. m3 40.00 0.00
2.2.4 In ramp restrain beams. m3 1.20 0.00
2.2.5 In entrance steps. m3 6.20 0.00
2.2.6 In 15 cm thick ground floor slab including ramps & half part of open market. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 1,213.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 187.00 0.00
2.3.2 To foundation column m2 236.00 0.00
2.3.3 To grade beams & ramps edge m2 296.00 0.00
2.3.4 To ramp restrain beam m2 12.00 0.00
2.3.5 To entrance steps m2 80.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 8 mm deformed bar Kg 124.00 0.00
Dia 12 mm deformed bar Kg 2,181.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 1,084.00 0.00
Dia 16 mm deformed bar Kg 1,770.00 0.00
Dia 20 mm deformed bar Kg 2,269.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 1,286.00 0.00
Dia 16 mm deformed bar Kg 3,783.00 0.00
2.4.4 For ramp restrain beam
Dia 8 mm deformed bar Kg 37.00 0.00
Dia 12 mm deformed bar Kg 71.00 0.00
2.4.5 For entrance steps
Dia 8 mm deformed bar Kg 448.00 0.00
Dia 16 mm deformed bar Kg 208.00 0.00
2.4.6 For floor slab on grade, ramp slab & outdoor tratment slab
Dia 8 mm deformed bar Kg 377.00 0.00
Dia 10 mm deformed bar Kg 9,488.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 87.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 26.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 29.10 0.00
1.1.2 In intermidiate beams m3 32.50 0.00
1.1.3 In top tie beams m3 13.60 0.00
1.1.4 In internal partition wall tie beams m3 2.16 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 232.00 0.00
1.2.2 To intermidiate beams m2 217.00 0.00
1.2.3 To top tie beams m2 127.00 0.00
1.2.4 In internal partition wall tie beams m2 21.60 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 1,288.00 0.00
Dia 16 mm deformed bar Kg 318.00 0.00
Dia 20 mm deformed bar Kg 2,540.00 0.00
1.3.2 For intermidiate beam
Dia 8 mm deformed bar Kg 693.00 0.00
Dia 16 mm deformed bar Kg 2,186.00 0.00
1.3.3 For top tie beam
Dia 8 mm deformed bar Kg 483.00 0.00
Dia 16 mm deformed bar Kg 1,507.00 0.00
1.3.4 For tinternal partiton tie beam
Dia 8 mm deformed bar Kg 99.54 0.00
Dia 12 mm deformed bar Kg 191.81 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct both-side decorative face red burnt 20cm thick (double) brick wall, built in approved red burnt clay face bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, with exposed face brick finish on both sides complete in every respect m2 677.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 909.00 0.00
3.2 Ditto as above item 3.1 but gable side pre-painted 0.5mm thick EGA-500 wall clad fixed to RHS frame as shown in the structural drawing. m2 68.00 0.00
3.3 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet ridge cup at the roof slope direction changes. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of ridge cap: 80 cm. m.l. 32.00 0.00
3.4 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 126.00 0.00
3.5 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 63.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors all as per the drawing. Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint.
D2 size 170cm x 260cm no 12.00 0.00
4.2 Supply, fabricate and fix metal guard rail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 120 × 120 × 6 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 1000 mm above finished floor level; two horizontal balustrade rails CHS Ø20 × 2.5 mm welded to vertical RHS posts; top handrail CHS Ø50 × 2.5 mm welded continuously; infill: vertically spaced CHS Ø20 × 2.5 mm at c/c 100 mm between the two horizontal rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 99.50 0.00
4.3 Supply, fabricate and fix metal ramp & step handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 38.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect Pre-Engineerered structures steel as primary and secondary members & all other reuired accessories.The material standard and fabrication be according to applicable American, British or Europian codes and standards. The material shall be as per approved pre-engineered building sysem standard and shall include column, rafter & truss (Hot rolled and built up I-sections), purlin (Rectangular hollow section), Bracings (rod Bracings), Screws, high strength bolts, Machine Bolts,Anchor bolts, Plates and other accessories.
The system is designed for Corrosively Category C3 and Long Design Life (15+ years) in accordance with ISO 12944. Prefabrication Primer Apply one coat of zinc-rich epoxy primer to a dry film thickness (DFT) of 20-25 µm. shop Coating: After fabrication, clean welds and bolt holes and apply full epoxy intermediate coat to achieve a minimum total shop DFT of 75 µm
All structural steel members shall be protected with an approved, certificated; thin-film intumescent coating system to achieve a fire resistance rating of R60. The required Dry Film Thickness (DFT) for the minimum intumescent coating shall be 1200 µm
All damage to shop coatings incurred during transport and erection shall be cleaned and repaired to the original specification. After erection, apply a final coat of an approved Polyurethane (PU) Topcoat. The total system DFT for the full corrosion protection system (primer, intermediate and topcoat) shall be a minimum of 285 µm over the entire structure.
All are as per the detail structural drawing and specification.
A. Primary Structure
A.1 Supply, fabricate, deliver, and erect IPE 400 steel column , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 400mm, flage width 180mm, web thickness 8.60mm, flange thickness 13.50mm & unit weight kg/ml 66.30kg/ml kg 915.00 0.00
A.2 Supply, fabricate, deliver, and erect IPE 400 rafter , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 400mm, flage width 180mm, web thickness 8.60mm, flange thickness 13.50mm & unit weight kg/ml 66.30kg/ml kg 11,537.00 0.00
A.3 Supply, fabricate, deliver, and erect IPE 100 canopy truss , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 100mm, flage width 55mm, web thickness 4.10mm, flange thickness 5.70mm & unit weight kg/ml 8.10kg/ml kg 671.00 0.00
B. Secondary Structure
B.3 Supply, fabricate, deliver, and erect IPE 300 secondary beam , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 300mm, flage width 150mm, web thickness 7.10mm, flange thickness 10.50mm & unit weight kg/ml 42.20kg/ml kg 2,532.00 0.00
C. RHS Purlins 0.00
C.1 RHS 100 x 100 x 4mm purlin fixed to upper truss member with 100 x 100 x 3mm L= 60mm angle iron. Price include angle iron. Kg 12,913.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
D. RHS Gable side frame 0.00
D.1 RHS 30 x 30 x 3mm RHS frame for gable side EGA wall clad support Kg 387.00 0.00
A.1 IPE 400 column & concrete colomn connection plate size 560 x 360 x 20mm with 8 dia 22mm sloted holes. No 24.00 0.00
A.2 IPE 400 column & rafter connection plate size 180 x 822 x 10mm with 12 dia 18mm sloted holes. No 24.00 0.00
A.3 IPE 400 column & IPE 300 secondary beam connection plate size 200 x 155 x 10mm with 4 dia 18mm sloted holes. No 40.00 0.00
A.4 IPE 400 rafter & rafter connection plate at Apex size 180 x 844 x 10mm with 4 dia 18mm sloted holes. No 12.00 0.00
A.5 IPE 100 truss & concete wall mounted connection plate size 200 x 200 x 10mm with 4 dia 14mm sloted holes. No 48.00 0.00
A.6 Stiffner size 180-80 x 10mm No 48.00 0.00
B Bolt with nut
B.1 Anchor bolt with nut column connection with concrete column M20 grade 8.8 depth 300mm No 96.00 0.00
B.2 Anchor bolt with nut canopy truss with concrete column M20 grade 8.8 depth 450mm No 192.00 0.00
B.3 Bolt with nut for column with rafter connection M 16 grade 8.8 No 144.00 0.00
B.4 Bolt with nut for column with secondary beam connection M 16 grade 8.8 No 80.00 0.00
B.5 Bolt with nut for rafter with rafter at Apex connection M 16 grade 8.8 No 72.00 0.00
B.6 C1022 hex head Tek screw fixed to concrete beam No 56.00 0.00
C Tension Cable
Supply, fabricate and install tension cable bracing system for steel roof trusses, comprising T32 mm threaded tension rods/cables, turnbuckles, coupling nuts, paddle braces, gusset plates, suspension plates, clevises, anchor connections, bolts, nuts, washers and all necessary fittings, complete with tensioning, alignment and fixing in accordance with the structural drawing, approved shop drawings and Engineer's instructions. Ml 214.40 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply three coats of cement sand plaster (1:3) for exposed beam and column surfaces.The final coat shall be made with fine sand sieved through a 1.18 mm mesh. surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks m2 576.00 0.00
6.2 Rake out joints where required and execute pointing to stone masonry joint work using cement-sand mortar of specified mix, including cleaning joints, wetting surfaces, filling, finishing, curing, and all necessary labor, materials, tools, and incidentals, complete in accordance with the drawings and specifications. m2 51.00 0.00
6.3 Rake out joints where required and execute pointing to decorative red brick joint work using cement-sand mortar of specified mix, including cleaning joints, wetting surfaces, filling, finishing, curing, and all necessary labor, materials, tools, and incidentals, complete in accordance with the drawings and specifications. m2 1,354.00 0.00
6.4 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect.for vegitable market. m2 299.00 0.00
6.5 10cm high 1cm thick chamfered ceramic skirting of matching color to floor tiles. ml 82.00 0.00
6.6 Provide and lay 50 mm thick cement-sand screed flooring, finished with a smooth steel-trowelled surface, using cement and clean sand mixed in the specified proportion (1:3 or as specified), laid to the required levels, slopes, and falls, including surface preparation, mixing, placing, compacting, leveling, finishing, curing, and all labor, materials, tools, equipment, and incidentals necessary to complete the work in accordance with the drawings and specifications for vegitable store m2 138.00 0.00
6.7 Provide broom finish to freshly placed concrete carway, Pavmeny & ramp surface, including screeding, leveling, texturing the surface with a broom to produce a uniform non-slip finish, and all labor, tools, equipment, and incidentals necessary to complete the work in accordance with the specifications and Engineer's instructions. Concrete work measured separately. m2 917.00 0.00
6.8 Supply and fix concrete copping for short wall . Price shall include cement sand mortar bed and cement grouting. ml 70.00 0.00
6.9 Construct Vegetable Display Raised Suspended Floor – comprising raised display platform formed with 50mm thick precast reinforced concrete slabs (1000 × 1200mm), supported on 100mm thick concrete block piers/walls at spacing and arrangement shown on the drawings; including under-display storage space complete with LTZ frame and 30 × 38mm steel louvered doors; 300 × 300 × 8.5mm ceramic floor/wall tiles fixed to the precast concrete top surface including adhesive, grout and all necessary cutting; complete with reinforcement, concrete block supports, fixing accessories, finishing, cleaning, and all incidental works necessary for a complete installation in accordance with the drawings and specifications. One unit covers 37.45m2 and we have 4 unit in total. Ls 1.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
7.1 Apply three coats of acrylic emulsion paint to exposed beam & column plastered wall surfaces. m2 576.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.3.2- Vegetable Market Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ELECTRICAL WORKS
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Flush-mounted sub distribution Board, SDB-VM in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 40A, 4P , Icu=10KA, coupled with RCD ,300mA Type S/ Time delayed 0.00
18pcs RCBO of 16A, 2P, Icu=6KA ,30mA 0.00
6pcs MCB of 10A, 2P, Icu=6KA
2pcs MCB of 16A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A, 3ph+N No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 44.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W,4000K, 3600Lumen, CRI > 80, ceiling-mounted, polycarbonate, flicker-free, IP66, for outdoor instalation No 9.00 0.00
1.3.L2E LED battenLight: L1200mm, 30W, 3600 lumens, 4000K, CRI > 80, surface-mounted.High-impact polycarbonate housing and diffuser with minimum IP65 protection rating , & ~1000 lumens (emergency), 4000K, 90 minute operation, No 3.00 0.00
1.3.L4 LED Highbay , pendant ( truss mounted), D273,h 93mm, 100w, 13000Lumens, 6500K, CRI>80. Die-cast aluminum housing with a clear optical polycarbonate lens (IP65 / IK06 rated) and a 100° to 110° wide beam angle. Complete with integrated driver, suspension mounting hook/accessories, and hardware. No 20.00 0.00
1.3.(E) Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). IP65,IK08, 5700K, minimum 7W, autonomy 90min. Warranty: 3 years (components), 5 years (battery). No 8.00 0.00
1.3.(EX) Saftey only emergency with FLC 11SE or approved equivallent illuminated signage system shall be installed to give information with standard dimensions information displays and illumination level with double or single faces. The display consisting of symbols, text or figures supported with direction which will indicate EXIT, toilets (lady and gentlemen), staircases and floor level will be placed as indicated on the drawings throughout building for the convenience of the public and workers .The symbols, text or figures shall be choices of the client or engineer and shall be appropriate enough to describe the room, areas, services and all safety directions it should have emergency battery for at least 2 hours . No 4.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Flush-mounted thumbler switch in sheet steel enclosure with lockable door with 6pcs of 16A/1Ph two way tumbler switchs including all necessary fixing and connecting accessories No 2.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 44.00 0.00
1.6 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.6.1 16A ,2P,230V 2p+e Doublesocket out let No 32.00 0.00
1.6.2 16A ,2P,230V 2p+e Doublesocket out let water proof for outdoor installation IP44. No 12.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.3.3- Crop & Vegetable Market Building-Sanitary
1 ROOF RAIN WATER DOWN PIPING SYSTEM USD 0.00
2 FIR FIGHTING SYSTEM USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ROOF RAIN WATER DOWN PIPING SYSTEM
1.1 Rainwater Downpipe DN 100 (Market Block) – Supply, install, test, and commission one uPVC rainwater downpipe, DN 100 mm nominal diameter, conforming to ISO 1452-1 or AS/NZS 1260, minimum wall thickness 2.5 mm. Include stainless steel leaf guard (5 mm mesh) at roof inlet, galvanized pipe brackets (vertical spacing 1.8 m maximum, horizontal spacing 1.0 m maximum), UV-reflective light-colored oil paint coating (white/light grey) conforming to ISO 4892-2 on all exposed sections, and discharge splash block at base. Complete from roof outlet to ditch/splash block. ml 290.00 0.00
1.2 Horizontal extension (sprout) from roof downpipe – 100mm diameter uPVC (or specified approved equivalent material), including bends, sockets, clips/supports at 1.0m intervals, and end outlet to ditch. Extend from downpipe discharge point to nearest ditch location as directed on site. Ensure minimum continuous fall of 1:100 towards ditch. All joints watertight. ml 145.00 0.00
Total carried to summary USD 0.00
2 FIR FIGHTING SYSTEM
2.1 Supply, install, test, and commission approved quality automatic fire water pump set (electric pump, diesel driven pump, and jockey pump) on common heavy-duty steel base plate (hot-dip galvanized, anti-vibration mounts) complete with all accessories, piping, valves, instrumentation, controls, civil works, testing, commissioning, training, and documentation as specified herein. 1.0 Single NFPA 20 Design Basis: The fire pump system shall be designed, supplied, and installed as a single integrated NFPA 20 system comprising electric duty pump, diesel standby pump, and jockey pump on a common skid. The design shall be based on a single hydraulic duty point: 200 GPM (12.62 L/s) @ 82 m head (119 psi). All components shall be selected and matched to this single design basis. The system shall be factory-tested as a complete assembly to verify performance at rated flow, shutoff, and 150% of rated flow. A certified pump performance curve shall be provided showing Head vs. Flow, Efficiency, Power (BHP), and NPSHR, with the operating design point clearly marked at 200 GPM @ 119 psi. 2.0 Pump Specifications: Referenced Aurora 2-384-11 @ 2,950 RPM or equivalent approved for the design duty point: Electric Pump (Primary Duty): 200 GPM (12.62 L/s) @ 149 psi (10.3 bar / 103 m) [exceeds design head of 119 psi], 30 hp (22.4 kW), 400 V / 50 Hz / 3-phase, TEFC motor, with minimum 85% efficiency. Diesel Standby Pump: 200 GPM (12.62 L/s) @ 149 psi (10.3 bar / 103 m), diesel engine rated at 33 bhp (24.6 kW) minimum (includes 10% NFPA 20 safety factor over pump BHP), radiator-cooled, 24 V electric start, with automatic battery charger and two (2) 120 Ah batteries. Jockey Pump (Pressure Maintenance): 15 GPM (0.95 L/s) @ 90 m head (123 psi), 0.75 kW (1 hp), 400 V / 50 Hz / three-phase.The electric fire pump controller shall be provided with a Soft Starter type starter suitable for the 22.4 kW (30 hp), 400 V, 3-phase, 50 Hz motor, to provide controlled acceleration, limit inrush current, and minimize mechanical shock to the pump and piping system. The soft starter shall comply with IEC 60947-4-2 (BS EN 60947-4-2), be listed for fire pump service, and include a bypass contactor for full-load operation. 3.0 Pump Performance Curve: The supplier shall provide a certified pump performance curve for the complete pump set showing the following: (i) Head vs. Flow curve (in m and GPM) from shutoff to 150% of rated flow; (ii) Efficiency curve (percentage) across the full operating range; (iii) Power curve (BHP/kW) for both electric and diesel drivers; (iv) Net Positive Suction Head Required (NPSHR) curve; (v) Operating point clearly marked at 200 GPM @ 149 psi. The curve shall be certified by the manufacturer and submitted with the equipment. 4.0 Skid Assembly: Factory-assembled, tested, and mounted on common heavy-duty steel base plate (hot-dip galvanized, anti-vibration mounts, lifting lugs). Physical dimensions: 2,600 mm (L) × 1,500 mm (W) × 1,800 mm (H) nominal. Integrated diesel fuel tank (minimum 200 Liters capacity) incorporated within the skid base structure. The complete skid assembly shall be installed at 400 mm above the pump room finished floor level (FFL) on a purpose-built reinforced concrete plinth. 5.0 Piping and Valves: Common suction manifold (DN 150) and delivery manifold (DN 100) with flanged connections; suction gate valves; delivery check valves (silent type); delivery gate valves; pressure relief valve (set at 9.65 bar/140 psi); air release valves; stop/isolation valves; Y-type suction strainer with blow-down and differential pressure gauge; test valve with drain pipe; flow meter (electromagnetic type, DN 100 with digital display); 2-way test header (DN 80 with two DN 65 hose connections). Flexible pipe connections shall be provided at suction and discharge to isolate vibration and allow for thermal movement. 6.0 Instrumentation and Controls: NFPA 20 compliant controller with automatic/manual operation, addressable, compatible with electric and diesel pumps; pressure sensors with manometers; pressure gauges (0–16 bar range with siphons); flow switch with alarm; pressure switch integration (6.9 bar/100 psi start pressure, adjustable); alarms (pump running, phase failure, low suction, engine faults, battery failure, fuel low, leak detection, pump on automatic, power available); remote monitoring dry contacts; weekly test timer; IP54 enclosure. 7.0 Diesel Fuel Tank: Double-walled steel tank with leak detection interstitial space; minimum 200 Liters capacity (sized for 12 hours run time per NFPA 20 Section 11.4.1.3.1); mechanical fuel level gauge; lockable fill cap with spill basin; drain valve; vent pipe with flame arrestor; complete fuel supply piping (flexible hose, isolation valve, filter). The tank shall be integrated into the skid base structure at the bottom of the skid frame. 8.0 Exhaust System (Diesel Standby Pump): Flexible stainless steel connector; critical grade silencer; schedule 40 steel exhaust pipe with rain cap; heat insulation where accessible with galvanized supports. Exhaust pipe shall be routed through the roof with weatherproof penetration. 9.0 Civil Assistance Works: Reinforced concrete plinth (300 mm height above pump room FFL) with dimensions adequate to support the skid footprint (minimum 2,400 mm × 1,600 mm × 300 mm) constructed of 25 MPa reinforced concrete. Plinth shall include anchor bolts with templates, load-bearing capacity to support skid weight plus full water content and dynamic loads, finished surface with slope to drain, drainage channel at plinth perimeter, ventilation louvers for engine cooling and combustion air, wall/roof penetration sleeves with fire-resistant sealant, and finished floor sloped to drain. The raised plinth shall provide flood protection and facilitate maintenance access to the skid unit. 10.0 Testing and Commissioning: Pressure testing (1.5 MPa/15 bar for 2 hours, no leakage); flow testing (rated flow and churn); diesel engine 1-hour full load run test; battery load test; full system commissioning as per NFPA 20. The complete skid assembly shall be tested as a single integrated unit to verify performance against the certified pump curve. 11.0 Documentation: Manufacturer's certificates; certified pump performance curves (Head vs. Flow, Efficiency, Power, NPSHR); driver kW ratings for electric motor (22.4 kW/30 hp) and diesel engine (33 bhp/24.6 kW minimum); controller specifications with wiring diagrams; NFPA 20 compliance documentation; test reports; commissioning report; warranties (12 months); O&M manuals (English/Arabic); as-built drawings; spare parts list; site training (2 days, 4 persons). 12.0 Compliance and Certification: NFPA 20 (latest edition); UL Listed / FM Approved (or equivalent) for fire protection service. Reference Brand/Model: Approved manufacturer's EDJ Series Fire Pump Skid (End Suction, Electric + Diesel + Jockey, 200 GPM @ 149 psi configuration) or approved equivalent. 13.0 Electrical Power Supply Requirements: The electrical supply shall be designed to support the fire pump system with the following connected loads: Main fire pump motor: 22.4 kW (30 hp), 400 V / 3-phase / 50 Hz, 45 A full load current; Jockey pump motor: 0.75 kW (1 hp), 400 V / 3-phase / 50 Hz, 2.0 A; Electric motor controller: 0.50 kW, 400 V / 3-phase / 50 Hz, 1.5 A; Diesel engine controller: 0.30 kW, 230 V / single-phase, 2.5 A; Battery charger (diesel): 0.30 kW, 230 V / single-phase, 1.5 A. Total connected load (electric): 23.65 kW. A dedicated 100 A, 3-phase circuit breaker. Notes: All works in accordance with manufacturer's instructions and locations shown on drawings. Price includes all necessary accessories required for proper operation but not specified or shown. Final physical dimensions to be confirmed by selected manufacturer. The raised plinth (300 mm above FFL) shall be constructed prior to skid installation. The single NFPA 20 design basis shall be documented with the certified pump curve, driver kW ratings, and controller specifications submitted as part of the equipment supply. SET 1.00 0.00
2.2 Supply, install, test, and commission fire water piping from GRP water tank fire reserve compartment to four (4) Class II hose reel cabinets, complete with DN 80 (3 inch) Schedule 40 black steel main pipe (ASTM A53 Grade B), DN 50 (2 inch) Schedule 40 branch pipes, all necessary fittings (90° and 45° elbows, tees, reducers), DN80 PN16 gate valves (bronze, rising stem) at tank outlet and pump discharge, DN50 PN16 gate valves at each hose reel branch (4 units), DN80 swing check valve at pump discharge, pressure gauge (0–200 psi) with siphon and isolation valve, 2-way test header with 65 mm hose connections, expansion joints (as required), galvanized steel pipe supports and hangers spaced per NFPA 14 Table 10.6.3.2.1, threaded or grooved joints (no welding unless specified), underground section (500 mm cover, sand bedding, anti-corrosion PET/bituminous wrap), exposed section with two coats of red epoxy fire-resistant paint (150 µm DFT, Sa 2.5 surface preparation), and clear labeling in English and Arabic (red bands/stickers at 10 m intervals stating "FIRE MAIN – HOSE REEL SYSTEM"). Pipe routing to cover total length of 150 meters (the unit price shal include fittings) as per design report, connecting to hose reel cabinets located in Crop Market Block (2 cabinets) and Vegetable Market Block (2 cabinets). Include full hydrostatic pressure test (15 bar for 2 hours, no leakage), flow test (757 L/min at ≥100 psi at most remote outlet), and flushing. Provide mill certificates, valve test reports, hydrostatic test report, flow test report, and as-built drawings. SET 1.00 0.00
2.3 Fire Hose Reel Cabinet Assembly (Class II) – Supply, install, and commission one complete Class II hose reel assembly conforming to NFPA 14, including: stainless steel/steel cabinet (1.2 mm thickness) with transparent panel, 30 m rubber-lined hose (19 mm internal diameter, 15 bar pressure rating), shut-off nozzle (6 mm orifice, solid stream/spray pattern), 1.5-inch (38 mm) inlet connection, non-return valve, angle valve with quick-release coupling. Mount at 1.2 m height to center of operating handle. Include red reflective labeling in English and Arabic. № 4.00 0.00
2.4 Portable Fire Extinguisher (ABC Dry Chemical) – Supply and mount one portable fire extinguisher, ABC dry chemical type (monoammonium phosphate, minimum 90%), stored-pressure type with metal valve body, pressure gauge with green zone indicator, corrosion-resistant finish, rating as specified, wall mounting bracket, inspection tag, and operating instructions in English and Arabic. № 14.00 0.00
2.5 Ditto ( 2.4) but CO2 type for pump/ control/panel room № 2.00 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.4.1- Multi Purpose Hall Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 GLAZING USD 0.00
8 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 230.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 115.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 189.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 19.00 0.00
1.5 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 27.00 0.00
1.6 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 100.00 0.00
1.7 Ditto as above item 1.5 but around isolated footing. m3 167.00 0.00
1.8 Ditto as above item 1.5 but around masonry foundation wall. m3 10.00 0.00
1.9 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 394.00 0.00
1.1 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 153.00 0.00
1.11 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 108.00 0.00
1.12 Ditto as above item 1.10 but construction joint between grade slab & grade slab where the slab area is larger. ml 28.00 0.00
1.13 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 93.00 0.00
2.1.2 Under masonry foundation wall m2 36.00 0.00
2.1.3 Under grade beam m2 8.00 0.00
2.1.4 Under slab on grade including ramp. m2 153.00 0.00
2.1.5 Under masonry steps on grade m2 1.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 34.00 0.00
2.2.2 In foundation column. m3 2.60 0.00
2.2.3 In grade beams. m3 6.30 0.00
2.2.4 In 10 cm thick ground floor slab including ramps & outdoor tratment. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 153.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 59.00 0.00
2.3.2 To foundation column m2 35.00 0.00
2.3.3 To grade beams & ramps edge m2 49.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 8 mm deformed bar Kg 56.00 0.00
Dia 12 mm deformed bar Kg 1,246.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 145.00 0.00
Dia 16 mm deformed bar Kg 737.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 227.00 0.00
Dia 12 mm deformed bar Kg 407.00 0.00
Dia 16 mm deformed bar Kg 102.00 0.00
2.4.4 For floor slab on grade, ramp slab & outdoor tratment slab
Dia 8 mm deformed bar Kg 624.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 36.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 1.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 5.80 0.00
1.1.2 In top tie beams m3 5.40 0.00
1.1.3 In lintel beams including roof vent windows m3 0.80 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 77.00 0.00
1.2.2 To top tie beams m2 62.00 0.00
1.2.3 To lintel beams including for roof vent windows m2 14.00 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 253.00 0.00
Dia 16 mm deformed bar Kg 839.00 0.00
1.3.2 For top tie beam
Dia 8 mm deformed bar Kg 227.00 0.00
Dia 12 mm deformed bar Kg 407.00 0.00
Dia 16 mm deformed bar Kg 102.00 0.00
1.3.3 For water tanker slab & beam
Dia 6 mm deformed bar Kg 24.00 0.00
Dia 12 mm deformed bar Kg 90.00 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for plastering. m2 173.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 192.00 0.00
3.2 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet ridge cup at the roof slope direction changes. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of ridge cap: 80 cm. m.l. 21.00 0.00
3.3 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 41.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors and windows all as per the drawing. All doors & windows should have vertical metal grill 25x25x2mm c/c 15cm behind glazing for burglar proofing. Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint. (glazing measured separately).
D-1 size 200cm x 360cm no 1.00 0.00
D-2 size 100cm x 360cm no 2.00 0.00
W-1 size 140cm x 250cm no 12.00 0.00
4.2 Supply, fabricate and fix metal ramp handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 3.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect steel structures using RHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards. Price shall include gusset plat, connection plate when truss members connect and bolts other than anchor/J-bolt bolts.
A.1 RHS 80 x 80 x 4mm upper & lower truss member for T1 Kg 1,100.00 0.00
A.2 RHS 60 x 60 x 4mm diagonal & vertical truss member for T1 Kg 695.00 0.00
B. RHS Purlins 0.00
B.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 40 x 40 x 3mm L= 40mm angle iron. Price include angle iron. Kg 1,526.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate for verenda post-size 250 x 250 x 6mm with 4 dia 18 slotted holes. The plated is welded to the RHS post (fillet weld of 3mm throat thickness) and connected to the other plate fixed on concrete column. No 24.00 0.00
A.2 Gussate plate size 200 x 160 x 6mm. The plate is welded to the truss (fillet weld of 3mm throat thickness) No 12.00 0.00
A.3 Gussate plate size 300 x 160 x 6mm. The plate is welded to the truss (fillet weld of 3mm throat thickness) No 24.00 0.00
A.4 Metal plate 40x200x3 welded to truss and bolted to angle iron-2 ∅8mm bolt to connect angle iron to metal plate No 72.00 0.00
B Bolt with nut
B.1 Base plate/Anchor bolt dia. 16 Length 250mm for truss beam connection and to be weld to ring beam steel reinforcement No 48.00 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of fine cement sand finish to internal brick wall surfaces. m2 177.00 0.00
6.2 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of fine cement sand finish to internal exposed beam and column surfaces. m2 21.00 0.00
6.3 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive rendering finish to externall brick wall surfaces. m2 146.00 0.00
6.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final rendering finish to external exposed beam and column surfaces. m2 41.00 0.00
6.5 Prepare the surface and apply final a 3 mm to 5 mm thick final skim coat using a 1:3 cement-to-fine-sand mortar mix. Fine sand must be sieved through a 1.18 mm mesh. The surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks to internal wall, beam & column surfaces. m2 198.00 0.00
6.6 Prepare the surface and apply final apply 15mm thick cement and sand rendering (1:3 mix) for external wall surface. Price includes surface preparation, hacking of concrete surfaces, wire mesh for joints, curing for 7 days. The rendering pattern shall be as per the Architect approval. m2 187.00 0.00
6.7 Prepare the surface, supply and construct 2 cm thick x 25 cm wide polished marble threshold for doors bedded on cement sand mortar 1:3. Price include 30mm thick cement sand mortar backing and white cement grouting. All are as per the detail Ar. Dwg. ml 4.00 0.00
6.8 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 155.00 0.00
6.9 10cm high 1cm thick chamfered ceramic skirting of matching color to floor tiles. ml 74.00 0.00
6.10 Supply and fix granite stair tread bedded on cement mortar 1:3 price include mortar bed, nosing and chamfering. Color and pattern shall be approved by the Architect.
a) For entrance step-tread
- Tread size: (33 x 3 cm) ml 4.20 0.00
6.11 Ditto as above but riser.
a) For entrance step-rise
- riser size: (13.4 x 2 cm) ml 4.20 0.00
6.12 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick terrazzo window sill. Price shall include cement sand mortar bed and cement grouting. ml 17.00 0.00
6.13 Supply and fix chamfered, bullnose and water dripped 25 x 3cm thick terrazzo edge trim for veranda edge. Price shall include cement sand mortar bed and cement grouting. ml 12.00 0.00
6.14 Supply and fix approved quality 60 x 60cm gypsum board suspended ceiling as per the detail drawing and engineers approval. The fixing method shall be with T & L aluminum suspension syste. Price shall include gypsum, suspension systemcorner list, nails and all the necessary fixing accessories. m2 155.00 0.00
6.15 10 cm thick Concrete pavement around the building bedded on 10 cm thick red ash or fine aggregate and 20cm thick compacted granular materials. The work shall be mixing, placing, compacting, curing, and finishing of concrete with trowel finish while fresh. Price shall include red ash bed, selected fill and trowel finishing work. m2 58.00 0.00
Total Carried to summary USD 0.00
7.1 Supply and fix 0.5cm thick clear glass. Price shall include all the necessary fixing accessories. m2 42.00 0.00
7.2 Supply and fix 0.5cm thick figured glass. Price shall include all the necessary fixing accessories. m2 10.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
8.1 Apply three coats of plastic emulsion paint to internally plastered wall surfaces. m2 198.00 0.00
8.3 Ditto as item 8.1, but to chip wood ceiling. m2 155.00 0.00
8.3 Apply final acrylic emulsion point paint to external rendered wall surface, exposed R.C columns and beams. m2 187.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.4.2- Multi-Purpose Hall Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ELECTRICAL WORKS
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Flush-mounted sub distribution Board, SDB-MPH in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 25A,4P , Icu=10KA, coupled with RCD ,300mA, Type S/ Time delayed 0.00
3pc MCB of 20A, 2P, Icu=10KA
3pcs RCBO of 16A, 2P, Icu=6KA ,30mA 0.00
3pcs MCB of 10A, 2P, Icu=6KA
2pcs MCB of 16A, 2P (spare) Icu=10KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A, 3ph+N No 1.00 0.00
1.1.2 Flush-mounted sub distribution Board, SDB-UPS in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 20A, 2P, Icu=10KA ,coupled with RCD ,300mA, Type S/ Time delayed 0.00
3pcs RCBO of 16A, 2P, Icu=6KA, 30mA
2pcs MCB of 16A, 2P (spare) Icu=10KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A/1P+N. No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including unction boxes with covers insulating screw cap connectors complete. No 34.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L1 LED Panel Light: 600x600mm, 22.5W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 24.00 0.00
1.3.L2 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 4.00 0.00
1.3.(E) Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). IP65,IK08, 5700K, minimum 7W, autonomy 90min. Warranty: 3 years (components), 5 years (battery). No 5.00 0.00
1.3.(EX) Saftey only emergency with FLC 11SE or approved equivallent illuminated signage system shall be installed to give information with standard dimensions information displays and illumination level with double or single faces. The display consisting of symbols, text or figures supported with direction which will indicate EXIT, toilets (lady and gentlemen), staircases and floor level will be placed as indicated on the drawings throughout building for the convenience of the public and workers .The symbols, text or figures shall be choices of the client or engineer and shall be appropriate enough to describe the room, areas, services and all safety directions it should have emergency battery for at least 90min. No 1.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Double pole Switch No 4.00 0.00
1.4.2 Double pole Switch water proof for out door installation IP44. No 1.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 19.00 0.00
1.6 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.6.1 16A ,1ph ,230V 2p+e socket out let No 4.00 0.00
1.6.2 16A ,1ph,230V 2p+e socket out let water proof IP44. No 2.00 0.00
1.6.3 Dito but Double (Twin) Outlet No 6.00 0.00
1.6.4 Dito but Double (Twin) in Red for UPS Outlet No 7.00 0.00
Supply, install, test, and commission a 3.5 kVA, 230 V, single-phase online double-conversion UPS, complete with a minimum of 10 minutes of battery autonomy at full load, automatic static bypass, maintenance bypass, a sealed maintenance-free battery bank, intelligent battery charger, LCD display, pure sine wave output, power factor ≥ 0.9, and 95% efficiency in online mode. Communication interface, and all necessary protection, control, interconnecting cables, earthing, accessories, and mounting hardware. The UPS shall comply with IEC 62040-1, IEC 62040-2, and IEC 62040-3, and shall be complete with all materials and accessories required for a fully functional installation. No 1.00 0.00
1.8 DATA\ Telecome System 0.00
Tel/Data according to manufacturer’s and utility supplier’s requirements, supplied, installed, connected color coded including tags and tested, complete, all as specified and / or as shown on the drawings 0.00
Structured Cabling
Horizontal CAT6A Cabling
1.8.1 Tel/Data and Data/Data points fed through 2x(twisted pair category 6A UTP cable) inside FRLS PVC conduits of 20mm diameter and thickness not less than 1.5mm with conduits accessories (coupling, junction boxes) for tele/Data outlet socket. No 8.00 0.00
1.8.2 Cat 6A 24 port Patch Panel RJ 45 contact No 1.00 0.00
1.8.3 Cat 6A RJ 45 Patch Cord 0.5m, from switch to patch panels No 16.00 0.00
1.8.4 Cat 6A RJ 45 Patch Cord 3m, from outlets to workstation computers. No 8.00 0.00
Equipment Racking 0.00
1.8.5 Wall Mount metallic rack of 9U pivoting cabinet swing 19" steel enclosure with transparent and lockable door, Built-in PDUs (8-10 Outlets, Grounded) and cooling fans. No 1.00 0.00
1.8.6 1U Horizontal Cable Management Bars, 5 Vertical Plastic Hoops with Cover No 2.00 0.00
Information Outlets: Data &Voice 0.00
Extra Over Data Socket Outlets with Detachable Frames & Corresponding Box 0.00
1.8.7 2 x RJ45 8 Contact CAT6a Socket Outlets No 6.00 0.00
Active components Type CISCO or approved equivalent. 0.00
1.8.8 24-port Gigabit Data +2x10G uplink Switch . No 1.00 0.00
1.8.9 24 port voice patch panel for telephone connection No 1.00 0.00
1.8.10 Hybrid PBX with 24 Analog, with 4 trunk, Extension including Operator Phone No 1.00 0.00
1.8.11 Cat 6A RJ 11 Patch Cord 1m No 8.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.4.3- Multi-Purpose Hall Building-Sanitary
1 SANITARY EQUIPMENT & WATE PIPES USD 0.00
1 ROOF RAIN WATER DOWN PIPING SYSTEM USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.0 SANITARY EQUIPMENET ( FIXTURES )
All fixtures which are specified below is subject to the owner's / consultant's approval, based on samples, catalogues and brochures presented by the contractor. Unit price shall include all the necessary fixing brackets or hooks and all assistance civil works such as chiseling of walls, floors, beams and etc.
1.1 HAND WASH BASIN (ORDINARY)
Supply and fix R.A.K. or Equivalent, hand wash basins for first aid room made of white glazed vitreious china with REMER/JAQUAR or Equivalent chrome plated cold water tap, pedastal stand ,complete with stop & arrest valves on water inlet pipe. Chrome plated chain holder, P-smell trap with connection pipe, fittings, all other necessary etc.complete in all respects. Flexible hose to be REMER or Equivalent and should be capable of resisting pressure of 4 bar. P-smell trap should be brass chrome plated with 50mm height of water seal and trap. The unit price shall include 500ml automatic soap dispenser,crystal glass mirror of 500 x 400mm.
a) Size :- length X width (1000mm x 435mm) set 1.00 0.00
1.2 Supply, fix, test and commission floor drains made of polished steel, complete with P-smell trap /minimum seal depth 75mm/ and all other necessary fittings and accessories. No 1.00 0.00
1.3 Waste & vent Pipes and Accessories
All domestic waste pipe lines shall be uPVC (PN4) pipes and shall be provided with a minimum slope of 2% towards the outlet. All uPVC pipes and necessary fittings shall be standard quality and be free from damage during storage, construction and etc. Unit price shall include all the necessary assistance civil works, such as excavation cartaway, fixing or hanging to walls, beams or slabs.etc., necessary fittings such as bends, Y, T, FCO(Floor clean out) etc.
Dia. 50 mm ml 6.00 0.00
Total carried to summary USD 0.00
1.0 ROOF RAIN WATER DOWNPIPING SYSTEM
3.2 Rainwater Downpipe DN 100 (Office + Multipurpose Hall) – Supply, install, test, and commission one uPVC rainwater downpipe, DN 100 mm nominal diameter, conforming to ISO 1452-1 or AS/NZS 1260, minimum wall thickness 2.5 mm. Include stainless steel leaf guard (5 mm mesh) at roof inlet, galvanized pipe brackets (vertical spacing 1.8 m maximum, horizontal spacing 1.0 m maximum), UV-reflective light-colored oil paint coating (white/light grey) conforming to ISO 4892-2 on all exposed sections, and discharge splash block at base. Complete from roof outlet to ditch/splash block. ml 20.00 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.5.1- Security/Guard House Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 GLAZING USD 0.00
8 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 50.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 25.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 18.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 2.00 0.00
1.5 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 7.00 0.00
1.6 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 21.00 0.00
1.7 Ditto as above item 1.5 but around isolated footing. m3 17.00 0.00
1.8 Ditto as above item 1.5 but around masonry foundation wall. m3 4.00 0.00
1.9 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 61.00 0.00
1.1 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 19.00 0.00
1.11 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 15.00 0.00
1.12 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 7.00 0.00
2.1.2 Under masonry foundation wall m2 13.00 0.00
2.1.3 Under slab on grade including ramp. m2 19.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 1.75 0.00
2.2.2 In foundation column. m3 0.50 0.00
2.2.3 In grade beams. m3 1.20 0.00
2.2.4 In 10 cm thick ground floor slab including ramps & outdoor tratment. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 19.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 6.00 0.00
2.3.2 To foundation column m2 8.00 0.00
2.3.3 To grade beams & ramps edge m2 10.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 12 mm deformed bar Kg 85.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 29.00 0.00
Dia 16 mm deformed bar Kg 92.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 47.00 0.00
Dia 12 mm deformed bar Kg 98.00 0.00
2.4.4 For floor slab on grade & ramp slab
Dia 8 mm deformed bar Kg 77.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 13.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 1.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 0.75 0.00
1.1.2 In top tie beams m3 1.20 0.00
1.1.3 In lintel beams including roof vent windows m3 0.20 0.00
1.1.4 In lnternal partition tie beam m3 0.20 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 12.00 0.00
1.2.2 To top tie beams m2 14.00 0.00
1.2.3 To lintel beams including for roof vent windows m2 3.00 0.00
1.2.4 To internal partition tie beam m2 2.00 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 38.00 0.00
Dia 16 mm deformed bar Kg 199.00 0.00
1.3.2 For top tie beam
Dia 8 mm deformed bar Kg 47.00 0.00
Dia 12 mm deformed bar Kg 98.00 0.00
1.3.3 For lintel beam
Dia 6 mm deformed bar Kg 4.00 0.00
Dia 12 mm deformed bar Kg 15.00 0.00
1.3.4 For internal partition tie beam
Dia 8 mm deformed bar Kg 9.22 0.00
Dia 12 mm deformed bar Kg 19.54 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for plastering. m2 44.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 18.00 0.00
3.2 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 12.00 0.00
3.3 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 5.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors and windows all as per the drawing. All doors & windows should have vertical metal grill 25x25x2mm c/c 15cm behind glazing for burglar proofing. Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint. (glazing measured separately).
D-1 size 90cm x 210cm no 2.00 0.00
W-1 size 140cm x 120cm no 2.00 0.00
4.2 Supply, fabricate and fix metal ramp handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 5.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect steel structures using RHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel rafter
Steel rafters and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards. Price shall include gusset plat, connection plate when truss members connect and bolts other than anchor/J-bolt bolts.
A.1 RHS 100 x 60 x 3mm rafter Kg 63.00 0.00
B. RHS Purlins 0.00
B.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 40 x 40 x 3mm L= 40mm angle iron. Price include angle iron. Kg 129.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate for verenda post-size 250 x 150 x 6mm with 4 dia 18 slotted holes. The plated is welded to the RHS post (fillet weld of 3mm throat thickness) and connected to the other plate fixed on concrete column. No 8.00 0.00
A.2 Angle late size 150 x 150 x 6mm. The plate is welded to the rafter (fillet weld of 3mm throat thickness) No 8.00 0.00
A.3 Gussate plate size 40 x 200 x 3mm. The plate is welded to the truss (fillet weld of 3mm throat thickness) and bolted with 2 dia. 8mm bolt. Price include bolt No 12.00 0.00
B Bolt with nut
B.1 Base plate/Anchor bolt dia. 16 Length 250mm for truss beam connection and to be weld to ring beam steel reinforcement No 12.00 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final/third coat of fine cement sand finish to internal brick wall surfaces. m2 49.00 0.00
6.2 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of fine cement sand finish to internal exposed beam and column surfaces. m2 3.00 0.00
6.3 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive rendering finish to externall brick wall surfaces. m2 45.00 0.00
6.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final rendering finish to external exposed beam and column surfaces. m2 12.00 0.00
6.5 Prepare the surface and apply final a 3 mm to 5 mm thick final skim coat using a 1:3 cement-to-fine-sand mortar mix. Fine sand must be sieved through a 1.18 mm mesh. The surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks to internal wall, beam & column surfaces. m2 52.00 0.00
6.6 Prepare the surface and apply final apply 15mm thick cement and sand rendering (1:3 mix) for external wall surface. Price includes surface preparation, hacking of concrete surfaces, wire mesh for joints, curing for 7 days. The rendering pattern shall be as per the Architect approval. m2 57.00 0.00
6.7 Prepare the surface, supply and construct 2 cm thick x 25 cm wide polished marble threshold for doors bedded on cement sand mortar 1:3. Price include 30mm thick cement sand mortar backing and white cement grouting. All are as per the detail Ar. Dwg. ml 1.00 0.00
6.8 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 13.00 0.00
6.9 10cm high 1cm thick chamfered ceramic skirting of matching color to floor tiles. ml 19.00 0.00
6.1 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick terrazzo window sill. Price shall include cement sand mortar bed and cement grouting. ml 3.00 0.00
6.11 Supply and fix approved quality 60 x 60cm gypsum board suspended ceiling as per the detail drawing and engineers approval. The fixing method shall be with T & L aluminum suspension syste. Price shall include gypsum, suspension systemcorner list, nails and all the necessary fixing accessories. m2 13.00 0.00
6.12 10 cm thick Concrete pavement around the building bedded on 10 cm thick red ash or fine aggregate and 20cm thick compacted granular materials. The work shall be mixing, placing, compacting, curing, and finishing of concrete with trowel finish while fresh. Price shall include red ash bed, selected fill and trowel finishing work. m2 9.00 0.00
Total Carried to summary USD 0.00
7.1 Supply and fix 0.5cm thick clear glass. Price shall include all the necessary fixing accessories. m2 3.36 0.00
7.2 Supply and fix 0.5cm thick figured glass. Price shall include all the necessary fixing accessories. m2 1.08 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
8.1 Apply three coats of plastic emulsion paint to internally gypsum plastered wall surfaces. m2 52.00 0.00
8.3 Ditto as item 8.1, but to chip wood ceiling. m2 13.00 0.00
8.3 Apply final acrylic emulsion point paint to external rendered wall surface, exposed R.C columns and beams. m2 57.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.5.2- Security/Guard House Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ELECTRICAL WORKS
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Flush-mounted sub distribution Board, SDB-SR1 in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 20A, 2P , Icu=10KA, coupled with RCD ,300mA, Type S/ Time delayed 0.00
1pcs RCBO of 16A, 2P, Icu=6KA ,30mA 0.00
1pcs MCB of 10A, 2P, Icu=6KA
1pcs MCB of 16A, 2P (spare) Icu=10KA 0.00
1Pc of surge arrestor of 20KA, Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A/1P+N. No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 6.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L1 LED Panel Light: 600x600mm, 22.5W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 1.00 0.00
1.3.L2 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 3.00 0.00
1.3.L3 Circular LED Ceiling Light D230, 13W, 400K,1300Lumen CRI > 80, ceiling-mounted, aluminum with acrylic diffuser, IP44, flicker-free. No 2.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Single Pole 1-Way Switch No 2.00 0.00
1.4.2 Single Pole 1-Way Switch, weather-proof IP54 No 1.00 0.00
1.4.3 Two Way Switch No 2.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 5.00 0.00
1.5 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.5.1 16A ,1ph ,230V 2p+e socket out let No 4.00 0.00
1.5.2 Dito but Double (Twin) Outlet No 1.00 0.00
1.6 DATA\ Telecome System 0.00
Tel/Data according to manufacturer’s and utility supplier’s requirements, supplied, installed, connected color coded including tags and tested, complete, all as specified and / or as shown on the drawings 0.00
1.6.1 2 x RJ45 8 Contact CAT6a Socket Outlets No 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.5.3- Security/Guard House Building-Sanitary
1 ROOF RAIN WATER DOWNPIPING SYSTEM USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ROOF RAIN WATER DOWN PIPING SYSTEM
1.1 Rainwater Downpipe DN 80 (Guard House) – Supply, install, test, and commission one uPVC rainwater downpipe, DN 80 mm nominal diameter, conforming to ISO 1452-1 or AS/NZS 1260, minimum wall thickness 2.0 mm. Include stainless steel leaf guard (5 mm mesh) at roof inlet, galvanized pipe brackets (vertical spacing 1.8 m maximum, horizontal spacing 1.0 m maximum), UV-reflective light-colored oil paint coating (white/light grey) conforming to ISO 4892-2 on all exposed sections, and discharge splash block at base. Complete from roof outlet to ditch/splash block. ml 20.00 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.6.1- Toilet -Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 156.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 78.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 36.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 4.00 0.00
1.5 Pit excavation for pit latrin in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 100 cm working space in each side for pit excavation. m3 80.00 0.00
1.5 Ditto as above item 1.5 but from 150cm to 300cm m3 32.00 0.00
1.6 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 11.00 0.00
1.7 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 69.00 0.00
1.8 Ditto as above item 1.7 but around isolated footing. m3 35.00 0.00
1.9 Ditto as above item 1.7 but around pit laterin shear wall m3 79.00 0.00
1.10 Ditto as above item 1.7 but around masonry foundation wall. m3 7.00 0.00
1.11 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 270.00 0.00
1.1 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 57.00 0.00
1.11 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 68.00 0.00
1.12 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 16.00 0.00
2.1.2 Under masonry foundation wall m2 23.00 0.00
2.1.3 Under grade beam m2 3.00 0.00
2.1.4 Under slab on grade including ramp. m2 57.00 0.00
2.2 10 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :under pit latterin bottom slab. 29.00 0.00
2.3 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.3.1 In isolated footing. m3 4.05 0.00
2.3.2 In foundation column. m3 0.80 0.00
2.3.3 In grade beams. m3 4.60 0.00
2.3.4 In 10 cm thick ground floor slab including ramps & outdoor tratment. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 57.00 0.00
2.3.5 In 15cm thick ramp slab. m2 3.00 0.00
2.3.6 In pit laterin bottom slab, shear wall & top slab m3 25.00 0.00
2.4 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.4.1 To isolated footing. m2 11.00 0.00
2.4.2 To foundation column m2 12.00 0.00
2.4.3 To grade beams & ramps edge m2 30.00 0.00
2.4.4 To pit latrin slab & shear wall m2 120.00 0.00
2.5 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.5.1 For footing pad
Dia 8 mm deformed bar Kg 13.00 0.00
Dia 12 mm deformed bar Kg 192.00 0.00
2.5.2 For Foundation column
Dia 8 mm deformed bar Kg 97.00 0.00
Dia 16 mm deformed bar Kg 343.00 0.00
2.5.3 For grade beam
Dia 8 mm deformed bar Kg 207.00 0.00
Dia 12 mm deformed bar Kg 404.00 0.00
2.5.4 For floor slab on grade, ramp slab
Dia 8 mm deformed bar Kg 247.00 0.00
Dia 10 mm deformed bar Kg 12.00 0.00
2.5.5 For fpit laterin
Dia 12 mm deformed bar Kg 3,170.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 23.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 1.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 2.40 0.00
1.1.2 In top tie beams m3 3.65 0.00
1.1.3 In internal partition tie beams m3 1.32 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 28.00 0.00
1.2.2 To top tie beams m2 42.00 0.00
1.2.2 To internal partition tie beams m2 13.20 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 154.00 0.00
Dia 16 mm deformed bar Kg 249.00 0.00
1.3.2 For top tie beam
Dia 8 mm deformed bar Kg 139.00 0.00
Dia 12 mm deformed bar Kg 278.00 0.00
1.3.3 For internal partition tie beam
Dia 8 mm deformed bar Kg 60.83 0.00
Dia 12 mm deformed bar Kg 117.22 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for plastering. m2 131.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 75.00 0.00
3.2 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 23.00 0.00
3.3 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 16.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors and windows all as per the drawing. All doors infill/covered with 0.5mm thick flat metal sheet pannel & windows should have infil with vertical metal grill 25x25x2mm c/c 15cm . Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint.
D-1 size 100cm x 200cm no 2.00 0.00
D-2 size 80cm x 200cm no 10.00 0.00
W-1 size 60cm x 40cm no 12.00 0.00
4.2 Supply, fabricate and fix metal ramp handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 11.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect steel structures using RHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel rafter
Steel rafters and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards. Price shall include gusset plat, connection plate when truss members connect and bolts other than anchor/J-bolt bolts.
A.1 RHS 100 x 60 x 3mm rafter Kg 201.00 0.00
B. RHS Purlins 0.00
B.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 40 x 40 x 3mm L= 40mm angle iron. Price include angle iron. Kg 519.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate for verenda post-size 250 x 150 x 6mm with 4 dia 18 slotted holes. The plated is welded to the RHS post (fillet weld of 3mm throat thickness) and connected to the other plate fixed on concrete column. No 12.00 0.00
A.2 Angle late size 150 x 150 x 6mm. The plate is welded to the rafter (fillet weld of 3mm throat thickness) No 12.00 0.00
A.3 Gussate plate size 40 x 200 x 3mm. The plate is welded to the truss (fillet weld of 3mm throat thickness) and bolted with 2 dia. 8mm bolt. Price include bolt No 36.00 0.00
B Bolt with nut
B.1 Base plate/Anchor bolt dia. 16 Length 250mm for truss beam connection and to be weld to ring beam steel reinforcement No 24.00 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final/third coat of fine cement sand finish to internal brick wall surfaces. m2 140.00 0.00
6.2 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of fine cement sand finish to internal exposed beam and column surfaces. m2 18.00 0.00
6.3 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive rendering finish to externall brick wall surfaces. m2 104.00 0.00
6.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final rendering finish to external exposed beam and column surfaces. m2 33.00 0.00
6.5 Prepare the surface and apply final a 3 mm to 5 mm thick final skim coat using a 1:3 cement-to-fine-sand mortar mix. Fine sand must be sieved through a 1.18 mm mesh. The surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks to internal wall, beam & column surfaces. m2 158.00 0.00
6.6 Prepare the surface and apply final apply 15mm thick cement and sand rendering (1:3 mix) for external wall surface. Price includes surface preparation, hacking of concrete surfaces, wire mesh for joints, curing for 7 days. The rendering pattern shall be as per the Architect approval. m2 137.00 0.00
6.7 Prepare the surface, supply and construct 2 cm thick x 25 cm wide polished marble threshold for doors bedded on cement sand mortar 1:3. Price include 30mm thick cement sand mortar backing and white cement grouting. All are as per the detail Ar. Dwg. ml 14.00 0.00
6.8 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 59.00 0.00
6.13 Supply and fix 30 x 60 x 0.85 cm ceramic wall cladding, of matching color to floor, stuck to wall with cement sand mortar 1:3 backing and grouting with white cement wash. Price shall include rod anchors to backing. Size, color and pattern according to architect's drawings. m2 168.00 0.00
6.12 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick terrazzo window sill. Price shall include cement sand mortar bed and cement grouting. ml 8.00 0.00
6.15 10 cm thick Concrete pavement around the building bedded on 10 cm thick red ash or fine aggregate and 20cm thick compacted granular materials. The work shall be mixing, placing, compacting, curing, and finishing of concrete with trowel finish while fresh. Price shall include red ash bed, selected fill and trowel finishing work. m2 12.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
7.1 Apply three coats of plastic emulsion paint to internally gypsum plastered wall surfaces. m2 158.00 0.00
7.3 Apply final acrylic emulsion point paint to external rendered wall surface, exposed R.C columns and beams. m2 137.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.6.2- Toilet Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Flush-mounted sub distribution Board, SDB-TO-1 in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 16A, 2P , Icu=10KA, coupled with RCD ,300mA, Type S/ Time delayed 0.00
2pcs MCB of 10A, 2P, Icu=6KA
1pcs MCB of 10A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A/1P+N. No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 24.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W,4000K, 3600Lumen, CRI > 80, ceiling-mounted, polycarbonate, flicker-free, IP66, for outdoor instalation No 10.00 0.00
1.3.L3 Circular LED Ceiling Light D230, 13W, 400K,1300Lumen CRI > 80, ceiling-mounted, aluminum with acrylic diffuser, IP44, flicker-free. No 12.00 0.00
1.3.(E) Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). IP65,IK08, 5700K, minimum 7W, autonomy 90min. Warranty: 3 years (components), 5 years (battery). No 2.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Single Pole 1-Way Switch No 2.00 0.00
1.4.2 Double pole Switch No 3.00 0.00
1.4.3 Double pole Switch Weather proof for outdoor installation, IP54 No 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.6.3- Toilet Building-Sanitary
1 WATER SUPPLY SYSTEMS USD 0.00
2 WASTE WATER DRAINAGE SYSTEMS USD 0.00
3 ROOF RAIN WATER DOWNPIPING SYSTEM USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 WATER SUPPLY SYSTEMS
1.1 Water Supply Piping Systems
1.1.1 Polypropylene Random Copolymer (PPR) pipe system for gravity-fed water supply from EWT to faucet, PN10, complete with all necessary fittings,elbow,stop valve,coupler,adapter,wall brackets, joints, and accessories for a fully functional system. Pipe and fittings shall comply with ISO 15874 / DIN 8077/8078. The unit price shall include Low-pressure wall-mounted faucet, complete with: swivel spout, aerator, lever-operated handle, wall mounting plate, fixing screws, and all necessary accessories. Faucet shall be certified for operation at minimum 0.1 bar residual pressure.
PPR pipe, DN20, PN10, SDR 11 lm 6.00 0.00
1.1.2 Supply, deliver, mount, test, and commission a hot press molded sectional Glass Reinforced Plastic (GRP) water tank system with total effective capacity of 36,000 liters (36 m³), comprising fire reserve compartment (27,000 liters / 27 m³) and domestic/non-potable water compartment (9,000 liters / 9 m³) separated by a watertight GRP partition, with individual connections and isolation valves for each compartment to allow independent operation and maintenance. Tank to be manufactured from food-grade GRP material conforming to ISO 14692, complying with NFPA 22 (fire reserve) and WRAS/NSF 61 (domestic water), with external hot-dip galvanized steel bracing (ISO 1461) and UV-resistant coating (ISO 4892-2). Designed for atmospheric working pressure with minimum 300 mm freeboard and shall withstand hydrostatic test pressure of 1.5 times the design head. Tank to be installed at ground level on a reinforced concrete slab (minimum 500 mm thick) raised 500 mm above NGL for flood protection, with steel rebar reinforcement (12 mm diameter @ 200 mm centers) extending minimum 300 mm beyond the tank footprint, and 150 mm high flood curb around slab perimeter. Complete with lockable manhole cover (minimum 600 mm diameter) with insect-proof vent, screened vent with 12 mm mesh, internal GRP ladder, external aluminum ladder with anti-slip platform and guardrails (ISO 14122), mechanical "Cat and Mouse" water level indicator or ultrasonic level sensor (one per compartment), sampling tap for water quality testing, earth bonding connection, fall protection anchor point, and the following connections: DN50 PN16 inlet with bronze gate valve and float valve, DN50 PN16 domestic outlet with bronze gate valve and expansion joint, DN80 PN16 fire outlet with bronze gate valve and expansion joint, DN50 drain with bronze gate valve and scour outlet, and DN65 overflow with 12 mm insect-proof mesh screened and directed away from the tank. All piping and fittings to be uPVC or stainless steel with stainless steel bolts and EPDM/food-grade gaskets. Installation to include on-site assembly, watertight sealing, hydrostatic testing per compartment (24 hours, no leakage), disinfection and first-fill procedure, drainage channel around slab, and labeling "POTABLE WATER – FIRE & DOMESTIC SUPPLY" in English and Arabic. Provide manufacturer’s certificates, test reports, and O&M manuals. № 1.00 0.00
1.1.3 Ditto Item 1.1.2 but with total effective capacity of 8,000 liters (8 m³) serving non-potable toilet wash purposes (hand washing), with DN50 PN16 inlet, DN50 PN16 outlet, DN50 drain, and DN65 overflow connections, installed on a reinforced concrete slab raised 500 mm above NGL for flood protection, and labeled "NON-POTABLE WATER – TOILET WASH" in English and Arabic. set 1.00 0.00
1.1.4 Elevated Water Tank (250 Liters) – Supply, install, and commission one food-grade polyethylene elevated water tank, nominal capacity 250 liters, conforming to ISO 4422. Include structural support as shown in the detail structural drawing, float valve or level sensor (adjustable high/low setpoints), overflow pipe (DN 25) with screen,chlorination pipe DN32, drain plug, lockable lid, outlet strainer (1 mm mesh), and DN 25 /DN32 gate valve for isolation. Mounting height: 2.5 m above NGL. № 2.00 0.00
1.1.5 Supply, install, test, and commission a complete centrifugal pump set (twin) for water transfer duty from GRP tank to elevated water tanks (EWTs), fully functional system including all auxiliary components: centrifugal pump complete with electric motor (0.25 kW, 0.33 HP, 380/400V, 3-phase, 50 Hz), base frame, coupling guard, anti-vibration mountings, suction and discharge flanges, pressure gauge, priming plug, drain plug, and all necessary fittings. Pump suitable for pumping potable water at 60 L/min flow rate and 4.27 m total dynamic head (worst-case condition: Tank 1 isolated, full flow to Tank 2) as calculated in the hydraulic design. Provide Variable Frequency Drive (VFD) panel complete with inverter drive, PLC controller with PID control logic, digital display, manual/auto selector switch, emergency stop button, phase monitoring relay, overload protection, short circuit protection, and all necessary control wiring, VFD rated for 0.25 kW motor and IP54 enclosure. Provide ultrasonic level sensors for both elevated water tanks complete with 4-20 mA output, IP67 enclosure, mounting bracket, cable gland, and all necessary accessories (range: 0-1.0 m) with "Highest Level Dominant" control logic per API 2350. Provide pump suction pipe assembly with strainer complete with foot valve, suction strainer, flexible coupling, isolation valve, and all necessary fittings. Provide pump discharge pipe assembly complete with non-return valve (check valve), gate valve, pressure relief valve, pressure gauge with siphon and isolation cock, flexible coupling, and all necessary fittings. Provide pressure switch for pump control and protection complete with adjustable set points, NEMA 4 enclosure, and all necessary accessories. Provide control panel enclosure IP54 rated complete with main isolator switch, contactors, overload relays, fuses, indicator lamps, push buttons, terminal blocks, wiring duct, and all necessary internal wiring. Provide cable and wiring from control panel to pump, VFD, level sensors (for both EWTs), and power supply complete with armored cables, control cables, cable trays, conduits, glands, lugs, and all necessary accessories. Reference pump brand: PEDROLLO CP 100 or equivalent approved brand. № 2.00 0.00
1.1.6 High-Density Polyethylene (HDPE) pipe, PN10, SDR 17, black with blue stripes, complete with all necessary fittings, elbow, T connections,joints, and accessories for a fully functional water supply system. Pipe material shall comply with ISO 4427 / BS EN 12201. The unit price shall also consider Isolation/balancing gate valves, DN40/DN32/dn25, flanged ends, PN16, ductile iron body, complete with handwheel, gland packing, and all necessary accessories, air release valve, pressure release valve, washout connection at DN40 pipe.
HDPE pipe DN40 PN10 lm 50.00 0.00
HDPE pipe DN32 PN10 lm 24.00 0.00
1.1.7 Supply and installation of Dry Latrine Squatting Pan – Ordinary Type Heavy-duty vitreous china or FRP pan, no water seal, shallow profile with anti-splash lip, drop hole min. 180mm with pipe connection to the pit as shown on the drawing. Includes fixing to concrete slab. No water supply connection." № 10.00 0.00
1.1.8 Supply and installation of Dry Latrine Squatting Pan – PWD Type Accessible design for persons with disabilities. Heavy-duty FRP or china with raised footrests, pan rim height ≤200mm from floor. Includes stainless steel grab bars (wall-mounted, vertical & horizontal). Drop hole min. 200mm with pipe connection to pit as shown on the drawing. No water supply connection." № 2.00 0.00
Total Carried to summary USD 0.00
2 WASTE WATER DRAINAGE SYSTEMS
2.1 Pit Latrine Ventilation Pipe (DN 100) – Supply, install, and commission one uPVC ventilation pipe, DN 100 mm (4 inch), conforming to ISO 1452-1, including: pipe extending from 300 mm above pit floor to 1.0 m above highest roof peak, solvent welded joints, galvanized brackets at 2 m maximum intervals, weatherproof cowl (turbo vent or 180° bend with bird screen), stainless steel insect mesh (12 mm aperture) at top, and fly-proof mesh (2 mm aperture) at pit entry. № 4.00 0.00
2.1.2 Handwashing Station (Standard) – Supply, install, and commission one handwashing station comprising: concrete basin (2800×400×200 mm), twelve (12)(six (6) on each side) lever-operated chrome-plated brass tap, two liquid soap dispenser (500 mL), supply piping PPR and uPVC drainage piping to soak away pit. set 2.00 0.00
2.1.3 Dito No 2.1.2 but for drinking water fetching and with six(6) faucet at one side only. set 1.00 0.00
2.1.4 Soak Pit – Supply, excavate, construct, and commission one soak pit for handwashing station drainage, including excavation, stone/gravel filling, perforated pipe inlet, geotextile fabric lining, and covered top with inspection port. Dimensions as per standard design. set 3.00 0.00
2.1.5 Oil/Grease Interceptor (Concrete/Masonry Construction) Supply, construction, and installation of a reinforced concrete or masonry gravity grease interceptor for pre-treatment of greywater from handwashing basins prior to discharge to the soak-away pit. Works include excavation to required depth, installation of a 100-liter minimum capacity two-compartment interceptor constructed of precast or cast-in-place reinforced concrete (minimum 150 mm thick walls) or brick/block masonry laid in Portland cement mortar (minimum 125 mm thick walls) with waterproofed interior surface to ensure watertightness . The interceptor shall include: (i) an inlet pipe with a removable coarse screening basket or silt trap for capturing solids and food debris ; (ii) a baffle wall or vertical partition with a lower communication opening to allow gravity separation based on the density difference between water and grease/oil ; (iii) an outlet pipe with a T-shaped or baffled fitting to retain floating grease; (iv) a removable, lockable cast iron or reinforced concrete cover (minimum 400 mm diameter) with access for inspection, cleaning, and maintenance ; and (v) a manhole or access step for safe entry during maintenance . The rate shall include all labour, materials, tools, excavation, backfill, compaction, concrete works, reinforcement, formwork, waterproofing, pipe connections (inlet and outlet), cover, and testing for watertightness . Construction shall comply with WaterAid Technical Guidelines, Sphere Handbook (2018), and relevant IPC provisions for grease interceptors. ls 2.00 0.00
2.1.6 Infiltration Test for Soak-Away Design Carrying out of field infiltration (percolation) test at proposed soak-away pit location to determine site-specific soil infiltration rate for the design of greywater disposal system. Works include excavation of one trial pit (minimum 0.5m × 0.5m × 0.5m), saturation of the pit, measurement of water level drop over a minimum period of 4 hours, calculation of infiltration rate (mm/hr or L/m²/day), and production of a signed test report with results and recommendations for soak-away sizing. The test shall be carried out in accordance with WaterAid Technical Guidelines and Sphere Handbook (2018) standards. The rate shall include all labour, tools, water for testing, site supervision, and report preparation. ls 2.00 0.00
Total Carried to summary USD 0.00
3 ROOF RAIN WATER DOWNPIPING SYSTEM
3.1 Rainwater Downpipe DN 80 (Toilet Block) – Supply, install, test, and commission one uPVC rainwater downpipe, DN 80 mm nominal diameter, conforming to ISO 1452-1 or AS/NZS 1260, minimum wall thickness 2.0 mm. Include stainless steel leaf guard (5 mm mesh) at roof inlet, galvanized pipe brackets (vertical spacing 1.8 m maximum, horizontal spacing 1.0 m maximum), UV-reflective light-colored oil paint coating (white/light grey) conforming to ISO 4892-2 on all exposed sections, and discharge splash block at base. Complete from roof outlet to ditch/splash block. ml 20.00 0.00
Total Carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.7.1-Water Reservior Plat form & Pump Control Switch Room-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A 0.00
B. SUPER-STRUCTURE
1 BLOCK WORK USD 0.00
2 ROOFING USD 0.00
3 METAL WORK USD 0.00
4 STEEL STRUCTURE USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No additional allowance for working space to be considered for measurement. The site clearing area shall be the net built-up area including aprons, open ditch, entrance step and ramp. m2 74.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for the ground floor from the Average Natural Ground Floor Level (A.N.G.F.L.) to a depth not exceeding 150 cm. The volume of excavation shall be measured only over the net built-up area of the building footprint, excluding aprons, open ditches, and ramps. Working allowance: An additional 0.50 m width on each side of the excavation shall be included to allow for proper working space. Reference level (A.N.G.F.L.): The A.N.G.F.L. is defined as the average of the topographic ground levels taken at the building footprint prior to any excavation works, reduced by 20 cm to account for above work item site clearing. m3 23.00 0.00
1.3 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level. Note: measurement shall include 150 cm working space in each side for trench excavation. m3 21.00 0.00
1.4 Back fill under hard core and around the building with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 12.00 0.00
1.5 Back fill around masonry wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 8.00 0.00
1.6 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material. Disposal shall be measured as the net volume arising from the void created by the excavation, less excavated material backfill, filled and wheel spread within site or left stockpiled. m3 58.80 0.00
1.7 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 34.00 0.00
1.8 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone.only under concrete channel. m2 40.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately.
2.1 5 cm thick lean concrete in grade/class C-5 concrete, minimum cement content of 150 kg/m3 :
A. Under ground floor slab m2 21.00 0.00
B. Under masonry foundation wall m2 41.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
A. In grade beam m3 2.05 0.00
B. In 10 cm thick slab m2 40.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
To grade beam m2 21.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
A. For grade beam
Dia 8 mm deformed bar Kg 129.00 0.00
Dia 12 mm deformed bar Kg 205.00 0.00
B. For slab on grade
Dia 8 mm deformed bar Kg 159.00 0.00
Total carried to summary USD 0.00
3.1 50 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 21.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
1.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for pointing. price shall include pointing m2 42.00 0.00
Total carried to summary USD 0.00
2.1 Supply and fix approved standard pre-painted 0.35mm thick corrugated iron sheet (C.I.S.) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). m2 14.00 0.00
Total carried to summary USD 0.00
3.1 Double-leaf metal door constructed from 40×40×3 mm RHS steel for vertical and horizontal framing, fully welded and braced with similar RHS sections as shown in the Architectural drawings. Door to be infilled with galvanized steel wire mesh 2.5 mm dia. at 25 mm c/c, welded to frame. Include all necessary welding, surface preparation, one coat of primer, and two coats of synthetic enamel paint to all steel surfaces. All work to conform to detailed drawings and relevant standards.
A. Door D1 size 100 x 100 cm. no 1.00 0.00
B. Door D2 size 170 x 150 cm. no 1.00 0.00
3.2 Wire mesh covering for pump control switch side walls made of galvanized steel wire mesh 2.5 mm diameter, spaced at 25 mm c/c, fixed securely to RHS structural frame using appropriate clamps or welding as shown on the drawings. The work includes cutting, fitting, welding (where required), surface preparation, one coat of metal primer, and two coats of synthetic enamel paint on all steel members. All materials and workmanship shall comply with the relevant standards and detailed drawings. m2 9.68 0.00
Total carried to summary USD 0.00
4 STEEL STRUCTURE
4.1 Supply, fabricate, assemble, and erect steel structures using RHS and CHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel Structure Column
Steel structure columns are vertical primary load-bearing members, transferring axial loads (and occasionally bending) from trusses to foundations. Since columns are in direct contact with water during cleaning, apply bituminous damp-proof paint at the column base up to a height of 300 mm (30 cm) to prevent corrosion and moisture penetration.
A.1 steel structure column using two RHS sections, 60 × 60 × 3 mm. not welded part single unit. kg 86.00 0.00
B. Steel Structure Column Beam
The beam shall be welded column to column just below the top plate level where truss and column connected. At the end of the beam where there is no steel column. it connected with the existing building it will be fixed with plate at the concrete column/tie beam
B.1 RHS 60 x 60 x 3mm beam kg 195.00 0.00
C. Steel rafter
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards.
C.1 RHS 80 x 60 x 3mm rafter kg 69.00 0.00
D. RHS Purlins 0.00
D.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 100 x 40 x 3mm L= 60mm angle iron. Price include angle iron. kg 106.00 0.00
4.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate size 150 x 150 x 8mm with 4 dia.18 slotted holes for dia. 16 J-bolt No 8.00 0.00
A.2 Metal plate 40x200x3 welded to truss and bolted to angle iron-2 ∅8mm bolt to connect angle iron to metal plate No 32.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.7.2.1-Pump Control Switch Room-1-Electrical
ITEM DESCRIPTION UNIT QTY RATE TOTAL
Supply and install:-
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Factory assembled and tested surface-mounted Sub distribution Board, SDB-PH1 in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories, and consisting: 0.00
1pc main MCB of 20A, 2P, Icu=10KA, coupled with RCD ,300mA Type S/ Time delayed 0.00
2pcs RCBO of 16A, 2P, Icu=6KA , 30mA 0.00
1pcs MCB of 10A, 2P, Icu=6KA
2pcs MCB of 16A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer 0.00
with 25% reserve space and busbar of 63A, 3ph+N No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 1.00 0.00
1.3 Light Fittings and Lamps 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 2.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Single pole Switch water proof IP44 No 1.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 2.00 0.00
1.6 Power outlet points.
1.6.1 16A/1P power outlets point for domestic water pump fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 1.00 0.00
1.6.2 100A/3P power outlets point for Fire Pump set control panel fed through XLPE insulated fire rated conductors of 3x35/16+16 mm² inside PVC conduits of 100mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 1.00 0.00
1.7 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.7.1 16A ,1ph ,230V 2p+e socket out let water proof IP44 No 2.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.7.2.2-Pump Control Switch Room-2-Electrical
ITEM DESCRIPTION UNIT QTY RATE TOTAL
Supply and install:-
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Factory assembled and tested surface-mounted Sub distribution Board, SDB-PH2 in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories, and consisting: 0.00
1pc main MCB of 20A, 2P, Icu=10KA, coupled with RCD ,300mA Type S/ Time delayed 0.00
2pcs RCBO of 16A, 2P, Icu=6KA , 30mA
1pcs MCB of 10A, 2P, Icu=6KA 0.00
2pcs MCB of 16A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A/1P+N. No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 1.00 0.00
1.3 Light Fittings and Lamps 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 2.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Single pole Switch water proof IP44 No 1.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 2.00 0.00
1.6 Power outlet points.
1.6.1 16A/1P power outlets point for domestic water pump fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 1.00 0.00
1.7 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.7.1 16A ,2P,230V 2p+e socket out let water proof IP44 No 2.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.8-Solid Waste Collection-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A 0.00
B. SUPER-STRUCTURE
1 BLOCK WORK USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No additional allowance for working space to be considered for measurement. The site clearing area shall be the net built-up area including aprons, open ditch, entrance step and ramp. m2 30.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for the ground floor from the Average Natural Ground Floor Level (A.N.G.F.L.) to a depth not exceeding 150 cm. The volume of excavation shall be measured only over the net built-up area of the building footprint, excluding aprons, open ditches, and ramps. Working allowance: An additional 0.50 m width on each side of the excavation shall be included to allow for proper working space. Reference level (A.N.G.F.L.): The A.N.G.F.L. is defined as the average of the topographic ground levels taken at the building footprint prior to any excavation works, reduced by 20 cm to account for above work item site clearing. m3 9.00 0.00
1.3 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level. Note: measurement shall include 150 cm working space in each side for trench excavation. m3 9.00 0.00
1.4 Back fill under hard core and around the building with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 8.00 0.00
1.5 Back fill around masonry wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 3.00 0.00
1.6 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material. Disposal shall be measured as the net volume arising from the void created by the excavation, less excavated material backfill, filled and wheel spread within site or left stockpiled. m3 24.00 0.00
1.7 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 13.00 0.00
1.8 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone.only under concrete channel. m2 11.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately.
2.1 5 cm thick lean concrete in grade/class C-5 concrete, minimum cement content of 150 kg/m3 :
A. Under ground floor slab m2 11.00 0.00
B. Under masonry foundation wall m2 9.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
A. In grade beam m3 1.10 0.00
B. In 10 cm thick slab m2 11.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
To grade beam m2 9.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
Dia 8 mm deformed bar Kg 33.00 0.00
Dia 12 mm deformed bar Kg 60.00 0.00
B. For slab on grade
Dia 8 mm deformed bar Kg 47.00 0.00
Total carried to summary USD 0.00
3.1 50 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 8.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
1.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for pointing. price shall include pointing & concrete copping on top of the short wall m2 40.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.9-Site Works-Civil
1 Gravel Finish- Compound Surface USD 0.00
2 Perimeter Fence with Gate USD 0.00
3 Landscaping Work USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 Interlocking Tile for Walk & Car way way
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net pavment area including curbstone. m2 2,358.20 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes curb stone. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 1,179.10 0.00
1.3 Load and cart away surplus excavated material to a suitable damping area allowed by the municipality not more than 5km from the site. m3 1,650.74 0.00
1.4 Selected fill to 95% MDD, including watering and rolling as shown the drawing m3 1,179.10 0.00
1.5 Supply and place crushed stone base course (C-4) 100 mm thick, including spreading, watering, and compaction to 95% MDD. m3 235.82 0.00
1.6 Supply and lay clean coarse sand bedding layer, 30–50 mm thick, leveled and compacted. m3 117.91 0.00
1.7 Supply and lay hand-dressed natural basalt/granite cobblestones (approx. 150×150×150 mm), tightly packed with joints filled with sand or cement-sand slurry as directed by the Engineer. m2 2,358.20 0.00
1.8 Edge restraint using concrete curb (150×400 mm) including excavation, formwork, placing, and finishing. ml 622.00 0.00
1.9 Pointing and final compaction of cobblestone surface including sweeping fine sand into joints and watering. m2 2,358.20 0.00
1.10 Supply, fabricate and fix steel bollards with steel chains for physical protection at conflict points, as follows: Bollards: Fabricated from 100 mm diameter galvanized steel pipe (CHS) 900 mm height above ground level fixed to 300 x 300 x 300 mass concrete foundation anchor with angle iron as shown on the detail drawing the bollard specing shall be c/c 1000mm. the space between the bollards shall be fixed with chain made of Heavy-duty 6 mm diameter steel chain, galvanized finish, connected to bollards using industrial-grade eye-bolts/hooks at the specified height. Fabrication, welding, installation, and fixing strictly as per drawings and engineer’s instructions. Price includes all materials (steel sections, chains, anchor bolts), excavation, concrete foundation, welding, surface preparation (grinding, de-scaling), one coat of anti-rust primer, two coats of exterior-grade metal paint, transport to site, and all necessary labor, tools, and equipment to complete the installation. Ml 159.00 0.00
Total Carried to Summary (USD) 0.00
2.1 Supply, fabricate, and install galvanized steel wire mesh perimeter fence comprising 40 × 40 × 2 mm angle iron vertical posts spaced at 2800 mm centers, fixed in concrete pad foundations, with top, middle and bottom horizontal rails (30 × 30 × 2 mm angle iron). The fence infill to be galvanized steel wire mesh (Ø 2.5 mm, 50 × 50 mm grid) securely fixed to the frame. The work also include three rows of barbed wire for security. The rate shall include excavation, concrete works, anti-rust treatment, metal painting,fabricated from similar materials, complete with all accessories and incidental work to complete the work, in accordance with the detail drawing,specifications and Engineer’s instructions. ml 366.00 0.00
2.2 Supply, manufacture & errect main entrance and exit metal door. Price shall include preparation and all necessary incidenatal work to complete the work. Alla are as per the Architectural and structural detail drawing. The work also include gate concrete post as shown in the detail structural drawing No 4.00 0.00
Total Carried to Summary (USD) 0.00
3 LANDSCAPING WORKS
3.1 Excavate the top soil to an average thickness of 20cm.for greenery part m² 761.00 0.00
3.2 Bulk excavation to remove the ordinary soil depending up on the actual level but not exceeding 50cm from reduced ground level. m3 380.50 0.00
3.3 Load and cart away surplus excavated material to a suitable damping area allowed by the municipality not more than 5km from the site. m3 532.70 0.00
3.4 Supply, well decomposed animal manure or equivalent organic material to be mixed with the topsoil averagely 300mm and to use in backfilling of planting pits.Price shall include all the necessary works to complete the work. Provide 1kg sample and details of supplier With quotation for Landscape Architect’s approval. m³ 228.30 0.00
PLANTING INSTALLATION OF GROUND COVERS:
3.5 Provide and plant grass as selected by the landscape architect. price includes gras as per the detail Architectural drawing. m2 543.00 0.00
3.6 Maintenance of lawn , grass, trees, shrubs, seasonal flower bed, other plantation and horticultural operations for weeding, watering, spreading of manure, good earth , fertilizers, spray of insecticides, fungicides, hoeing, pruning of tree/shrubs/hedge plants grassing garden swords, anti-termite treatment. Rates to include cost of material, all labor, tools & tackles, cost of manure, earth, fertilizer, pesticides etc. and also providing complete arrangement at site/sites for grass cutting by brand new power run lawn mower with skilled machine man & labor, diesel, lubricant to ensure mowing on barns and by manual labor through garden sward on the slop of under pass of the grass at least 3 times / month complete Month 2.00 0.00
Total Carried to Summary (USD) 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.10-Site Works-Electrical
ITEM DESCRIPTION UNIT QTY RATE TOTAL
1 Manhole for Electrical Systems
1.1 Construct rectangular double red burnt brick electrical manholes of internal dimensions 800mm × 800mm × 600mm (MH-2) in accordance with the detail drawings and specifications. The manhole shall comprise 250mm thick double red burnt brick masonry walls, internally plastered with cement-sand mortar, a 100mm thick reinforced concrete base slab, and a 100mm thick removable reinforced concrete cover slab complete with flush-type cover, all as approved by the Engineer. The rate shall include excavation to the required depth, disposal/cart-away of surplus excavated material, back-filling and compaction around the structure, supply and placement of concrete, reinforcement, form-work, brick masonry, plastering, curing, and all associated civil works, labor, materials, tools, and incidentals necessary for the complete and proper construction and functioning of the electrical manhole system. Set 3.00 0.00
1.2 uPVC Pipes and Ducts
1.2.1 100mm diameter uPVC m 60.00 0.00
1.2.2 50mm diameter uPVC m 500.00 0.00
1.3 Earth Network (Grounding System)
1.3.1 Grounding pit 600x600x700mm with top cover inscribed "Grounding pit" as per the detail drawing. (MH-1) No 6.00 0.00
1.3.2 Bare ground connecting copper cable of 1x70sq.mm ml 450.00 0.00
1.3.3 Earthing electrode diameter 20mm and length 3000mm 0.00
copper rode 0.00
Note: If the earth resistance is more than 10 ohms 0.00
add additional electrode spaced at length of 0.00
the electrode (spaced at a minimum of 5m apart) No 6.00 0.00
1.3.4 Equipotential Bonding - Supply and installation of complete equipotential bonding system with appropriate size equiptential earth bar to be palce near to the main board as shown in the drawing, for all applicable exposed and extraneous metallic parts, including structural steelwork, metallic water pipes, HVAC/MEP services, and other metallic services, using appropriately sized copper bonding conductors, bonding clamps, terminals, connectors, and all necessary accessories, connected to the Main Earth Bar in accordance with the design, applicable standards, and drawings. LS 1.00 0.00
1.4 DISTRIBUTION BOARDS 0.00
1.4.1 Factory assembled and tested surface-mounted Central main distribution Board, CMDB in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories, and consisting:
1pc main MCCB of 160A, 3P+N/2, adjustable magnetic (short-circuit) protection only, Icu=16KA
1pcs MCCB of 100A, 3P+N/2, adjustable magnetic (short-circuit) protection only, thermal/overload protection disabled or excluded, suitable for fire pump feeder, Icu=10KA
1pcs MCCB of 100A, 3P+N/2, Icu=16KA
1Pc of surge arrestor of 40KA Type 1 , coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
3 pcs current meters of 160/5A with 6A fuse
1 pc Volt meter of 500V with selector switch and 6A fuse
1 pc frequency meter
with 25% reserve space and busbar of 200A/3ph+N. No 1.00 0.00
1.4.2 Factory-assembled and tested surface-mounted main distribution Board (MDB) in a sheet steel enclosure with a lockable door, including all necessary fixing and connecting accessories, and consisting:
1pc main MCCB of 100A, 3P+N/2 , Icu=10KA coupled with 500mA, RCD. Type S/ Time delayed
1pcs MCB of 40A, 4P, Icu=10KA
1pcs MCB of 32A, 4P , Icu=10KA
1pcs MCB of 25A, 4P , Icu=10KA
2pcs MCB of 20A, 2P, Icu=6KA
2pcs MCB of 16A, 2P Icu=6KA
2pcs MCB of 25A, 4P (spare) Icu=10KA
with 25% reserve space and busbar of 125A/3ph+N. No 1.00 0.00
1.5 Feeder Cables and PVC pipes 0.00
XLPE Insulated PVC Sheathed 0.6/1KV power cable (IEC 60502-1), or approved equivalent to be drawn inside riser shaft or PVC conduit (measured elsewhere, tentative) and of:- 0.00
Cable sizes include: 0.00 0.00
1.5.1 3X95/50+50 mm2 From TX to CMDB m 10.00 0.00
1.5.3 3X35/16 mm2 CMDB to Firefighting CP ( Fire rated cable) m 45.00 0.00
1.5.4 4x16 mm2 From MDB to SDB - VM m 30.00 0.00
1.5.5 4x10 mm2 From MDB to SDB - CM, m 180.00 0.00
1.5.6 4x6 mm2 From MDB to SDB-MPH m 150.00 0.00
1.5.7 3x4 mm2 From MDB to SDB SR1, m 10.00 0.00
1.5.8 3x4 mm2 From SDB-MPH to UPS, from UPS to SDB - UPS m 20.00
1.5.9 2x4 mm2 From MDB to SDB -PH1, From SDB-MPH to SDB-PH2 & SDB-SR2 m 200.00 0.00
1.5.10 3x2.5 mm2 From SDB -PH-1 to SDB-TO-1, From SDB -PH-2 to SDB-TO-2 m 30.00 0.00
1.5.11 1x16mm2 earthing cable from Fire pump CP to Earth rode, From SDB-VM to Earth rode m 20.00
1.5.12 1x10 mm2 from SDB-CM to Earth rode, m 15.00
1.5.13 1x6mm2 earthing cable From SDB-MPH to Earth rod m 15.00
1.5.14 1x4mm2 earthing cable From SDB-PH1, SDB-PH2, SDB-SR2 to Earth rode m 35.00
1.6 Light Fittings and Lamps 0.00
. Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing. IEC 60969 standards or equivalent and type approved 0.00
1.6.SL1 LED Solar Street Lights for Outdoor, at least 15000 Lumens DA high-brightness, all-in-one solar street light for perimeter lighting, powered by sunlight with no electricity costs. Key Specifications Brightness: ≥15,000 lumens (bright as daylight) Light Type: LED (SMD 2835 or CREE 3030 chips) Color: Cool white (6000K–6500K) Solar Panel: 120-watt monocrystalline (charges in 6 hours) Battery: LiFePO4, ≥7-year lifespan, 3-day backup capacity. Operation: Dusk-to-dawn (auto on/off with daylight sensor) Motion sensor (full brightness on movement, dims to save energy) Remote control (adjust brightness, set timers) Weatherproof: IP65 (waterproof, dustproof, works in rain or heat) Material: Aluminium housing, tempered glass cover Runtime: 11 hours after 6-hour charge; up to 18 hours in dim mode Installation: Pole or wall mount (6ms height), no wiring needed Durability: Works in -22°F to 140°F; 50,000+ hour lifespan Warranty: 3–5 years, The luminaire shall incorporate an integrated surge protection device (SPD), minimum Type II, suitable for outdoor LED lighting applications, with a nominal discharge current (In) of at least 10 kA and a maximum discharge current (Imax) of at least 20 kA. Complete with all accessories necessary for installation and commissioning. No 21.00 0.00
1.6.2 Supply, install, test, and commission a 6 m high hot-dip galvanized octagonal steel pole, complete with luminaire outreach arm, suitable for supporting an integrated solar LED street lighting system including battery box at 5m height, and all associated mounting accessories. The pole shall have a base diameter of 140 mm and a top diameter of 60 mm, and shall be supplied complete with base plate, foundation anchor bolts, templates, and all necessary fittings. The pole shall be designed and manufactured in accordance with EN 40-3-1 and rated for a reference wind velocity of 30 m/s (108 km/h). Complete concrete pole foundation/pad,including setting out, excavation, disposal of surplus material, preparation and compaction of formation, selected backfill and compaction, blinding concrete where required, reinforced concrete, reinforcement steel, formwork, anchor bolts, plate nuts, washers, templates and non-shrink grout; installation, alignment and commissioning of pole, PV panel and luminaire; testing of PV charging, battery operation and lighting performance; and all labor, materials, equipment, transportation, tools and incidentals necessary to provide a complete and operational solar PV lighting system in accordance with the approved drawings and specification Complete in accordance with the drawings and technical specifications. No 21.00 0.00
1.7 Lightning Arrester System
(Eritech or Equivalent)
Shall include all metalic structures in the network with appropriate welding (ventpipes,ducts ,GIS roof & structures, solar PV panels, e.t.c)
1.7.1 Early Streamer Emmision(ESE) Protector SI 60 with mounting mast of H=2.0m and all necessary connecting acessories. No 2.00 0.00
1.7.2 25x3mm copper tape with all necessary roof connecting accessories m 60.00 0.00
Down conductor 0.00
1.7.3 25 x 3mm insulated copper tape with vertical supportings every 0.3m to the wall & all the necessary accessories coordinate the routing of down conductors with the building external skin and architectural features. ml 30.00 0.00
1.7.4 Lightening Event counter to be installed on the down conductor to count number of lightening strikes. No 4.00 0.00
1.7.5 Test point (junction box) with all necessary connection acessories to connect the down conduction with the earthing bare copper wire. at least 1.5m above floor finish. No 4.00 0.00
1.7.6 Prefabricated Crowsfeet 25x3mm tinned coper tape. In complienc with IEC-EN 62561-2, with L1=1000mm and L2= 3000mm No 6.00 0.00
1.7.7 50 x 50 x 50 cm test pit with top cover inscribed "Test pit" as per the detail drawing( MH-3) No 6.00 0.00
1.7.8 1 x 70 sq.mm bare copper wire ml 20.00 0.00
1.7.9 Earthing electrode Diameter 16mm & 1500mm long copper rod No 6.00 0.00
1.9 FIRE ALARM SYSTEM 0.00
1.9.1 16A/2PPower outlet point for fire alarm control panel and repeater panel , fed through fire rated cable of 3x2.5mm2 inside and including rigid PVC conduits of 19mm diameter including junction boxes with covers insulating screw cap connectors complete. No 2.00 0.00
1.9.2 RS-485 communication cable to connect FACP and Repeater panel. ml 170.00 0.00
1.9.3 Conventional Fire alarm Control Panel, Minimum of 3 zones Complete with power supply & battery backup, and RS-485 communication port for repeater panel. No 1.00 0.00
1.9.4 Conventional Fire alarm repeater Panel, 3 zones Complete with power supply & battery backup and RS-485 communication port. No 1.00 0.00
1.9.5 Smoke detector; with Flash Scan and Detector Base, Complete No 12.00 0.00
1.9.6 Fire alarm sounder strobe (RED), for outdoor use IP66 No 6.00 0.00
1.9.7 Outdoor manual call point complete with a lockable, transparent anti-vandal protective cover with local audible warning on cover lifting. The manual call point shall be resettable type, suitable for outdoor installation, minimum IP66 and IK10, UV-resistant, corrosion-resistant, and compatible with the fire alarm system. The unit shall comply with EN 54-11, and shall be complete with weatherproof mounting box, fixing accessories. No 12.00 0.00
1.9.8 Flush Mounted Fire Alarm Points (smock detectors, manual call points, sounders, and sounder beacons) fed in 2 x 2.5sq. mm fire-resistant, low-smoke, zero-halogen (FRLS/LSZH) fire alarm cable. For internal building installations, cables shall be installed in 19 mm diameter FRLS PVC conduits concealed or surface-mounted as specified. For external inter-building connections, cables shall be installed in 50 mm diameter heavy-duty uPVC conduits buried underground between blocks, complete with all necessary conduit accessories, including bends, couplings, adaptors, junction/pull boxes, warning tape, and draw wire No 30.00 0.00
1.9.9 Supply and installation of an end-of-line resistor, compatible with the specified fire alarm control panel and associated conventional detection/alarm circuits, complete with suitable enclosure/base, terminals, identification label, and all accessories required for proper termination and supervision of the circuit. Resistor value shall be as specified/ recommended by the fire alarm system manufacturer and shall be installed at the electrically final device/end of each supervised circuit. This includes testing, commissioning, and integration with the fire alarm system. No 3.00 0.00
1.10 Documentation 0.00
. Engineering, electrical installation as built drawings and O&M manuals. Qualified Set 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.11-Site Works-Sanitary
SITE DRAINAGE WORKS
1 SURFACE RAIN WATER DRAINAGE SYSTEM USD 0.00
2 GENERAL ITEMS USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 SURFACE RAIN WATER DRAINAGE SYSTEM
The rates for drainage ditches shall include full compensation for excavation, disposal of excavated material, preparation of subgrade, supply and placement of concrete (minimum 25 MPa compressive strength at 28 days) or masonry as specified, forming of trapezoidal or rectangular cross-section, installation of galvanized steel gratings where needed, construction of catch pits with debris screens, joint sealing, curing, and finishing to achieve Manning's roughness coefficient n = 0.017 for concrete ditches and n = 0.025 for masonry ditches, including all formwork, reinforcement where required, and erosion protection measures at outlets. For open ditch sections without covers, the rate per linear meter includes only the items above. For open ditch sections with integrated reinforced concrete covers at public/car way crossings, the rate per linear meter shall additionally include the supply and installation of concrete covers at locations and spacing shown on the drawings, each cover spanning the full ditch clear opening, designed for vehicle overrun loading (BS EN 124 Class B125 for car parks or D400 for carriageways as specified), including 25 mm cement mortar bedding on ditch walls, concrete grade minimum C30/37, reinforcement mesh top and bottom (minimum A142), formwork, non-slip surface finish flush to adjacent grade, galvanized lifting inserts for removal, and curing. No separate payment shall be made for excavation, backfill, disposal, bedding mortar, lifting provisions, or individual covers – the cost of covers at the indicated spacing is deemed included in the per linear meter rate for covered sections. Any gratings or covers damaged during construction shall be replaced at no additional cost.
1.1 Drainage Open Ditch – Supply, excavate, construct, and commission reinforced concrete drainage ditch, rectangular cross-section, with different internal dimensions, concrete grade minimum 25 MPa, smooth finish achieving Manning’s n = 0.017, including excavation to required depth, disposal of surplus material, formwork, reinforcement, joints (with waterstop where needed), and curing.. Provide a minimum slope of 1% or follow the natural ground slope which ever is greater
DITCH-: SIZE[mmXmm] = 600 X 600 ml 210.00 0.00
DITCH-: SIZE[mmXmm] = 200 X 350 ml 360.00 0.00
DITCH-: SIZE[mmXmm] = 400 X600 ml 100.00 0.00
1.2 Dito item No 1.1 but with integrated reinforced concrete cover at public/car way crossings – complete as specified, including all excavation, ditch lining, and concrete covers (BS EN 124 Class B125/D400 loading).
DITCH-: SIZE[mmXmm] = 600 X 600 ml 50.00 0.00
DITCH-: SIZE[mmXmm] = 200 X 350 ml 70.00 0.00
1.20 Catch Pit with Debris Screen – Supply, excavate, construct, and commission one catch pit at ditch junctions or before discharge points, including reinforced concrete construction, minimum 600×600×900 mm deep, removable heavy duty cast iron cover, stainless steel debris screen (12 mm mesh), inlet and outlet connections to adjoining ditches, and concrete base. № 6.00 0.00
Total carried to summary USD 0.00
2 GENERAL ITEMS
2.1 Allow for Testing and commissioning of the entire plumbing installation by a Chartered Mechanical Engineer and obtaining a Test Certificate (3rd party testing to approval of the Engineer) including all off-site and factory testing; inspections to demonstrate compliance with relevant standards, operating the completed installation and submitting all relevant test records and authority approval. LS 1 0.00
2.2 All sanitary fittings supplied shall be provided with a minimum 5 year warranty, issued jointly and severally by the local supplier and the manufacturer. LS 1 0.00
2.3 Allow for preparation of Operationa and Maintenance Manual including site users training for the O & M Maual of all plumbing and mechanical appliances. LS 1 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bill No.12-Signage
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 Directory Signs
Design, supply and install international standard Boy's, Girl's & PWD Toilet directional sign complete with pictogram (Girl's, Girl's & PWD toilet sign symbol) plus directional arrow that leading to the toilets. The sign shall also consist text “Boy's , Girl's & PWDToilet.” Sign shall be minimum size 300 mm × 400 mm, high quality tin: tin sign with retro design, metal tin, long-term use, not easy to damage, smooth surface, ...with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 3.00 0.00
2 Directory Signs
2.1 Supply and install main directional sign with text “To each building listed as Signage S-1 Architectural drawing with arrow, made of 3 mm thick photoluminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm for each building direction, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for outdoor mounting with weatherproof finish.Price include civil work to fix the signage post. No 1.00 0.00
2.2 Building departmet sign as the above item the text and size letter hight shall be as per the detail Ar. Signage and the name listed below.
A "Crop Market" sign fixed on the front side elevation No 1.00 0.00
B "Vegetable Market" sign fixed on the front side elevation No 1.00 0.00
C "Multi-Purpose Hall" sign fixed on the front side elevation No 1.00 0.00
D "Toilets" sign fixed on the front side elevation No 2.00 0.00
E "Security House 1 & 2" sign fixed on the front side elevation No 2.00 0.00
F "Solid Waste Collection" sign fixed on the front side elevation No 1.00 0.00
3 Room Identication Signs
Design and supply signage with room number in accordance with this specification and as directed by the Architect. The material shall be made of 3-5mm thick wall mounted Acrylic signs. The size shall be 250mm x 30mm and letter height shall be 50-70mm for room number, 25-40mm room name letters and braille and tactile characters where applicable. The color and contrast between the text and background shall be high and the color shall be consistent with the veternary clinic branding (if any) or as per the Architect approval. The topography and information shall be Room number: Bold, large font (sans serif preferred), Room function/name: Smaller font beneath the number (e.g., Room 101 – Office) and Braille/tactile lettering placed below the printed text. The signage shall be fixed to the wall at 1.4–1.5 m above floor to centerline of sign on the latch side of the door, or directly on the door if wall space is not available and it shall be fixed with secure concealed fasteners or adhesive (depending on wall/door material). The supplier shall produce and submit Mock-ups for approval before mass production. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect.
3.1 Male & female Rest rooms and with pictogram of gents, ladies and PWD No 4.00 0.00
3.2 First Aid sign as shown in the detail drawing No 4.00 0.00
4 Safety and Compliance Signs
4.1 Design, supply and install Entrance Sign in accordance with this specification and as directed by the Architect. The material shall be made of flame-retardant, impact-resistant ABS clear acrylic plate and shall comply with BS EN ISO 7010 Exit Symbol (E001) and shall have Multi-installation system: Hanging, wall or surface mounted depending on the location. The size of the letter height shall be minimum 150mm with a stroke width 19mm, color contrast to be white letters on green background and the sign shall consist text+ directional arrow that leading to entrance.The sign shall be fixed to entrance access point at 2.00–2.50 m above floor level. The supplier shall produce and submit Mock-ups for approval before mass production or procurement. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect. No 4.00 0.00
4.2 Supply and fix 3mm rigid PVC/acrylic Fire Extinguisher sign (300mm x 100mm) with 50mm high ISO-compliant white lettering on red background, including all fixings and installation. No 14.00 0.00
4.3 Supply directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. Supply and install directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. No 4.00 0.00
4.4 Supply emergency assembly point safety sign complete with standard ISO 7010 pictogram (E007: four people symbol) and text “EMERGENCY ASSEMBLY POINT.” Sign shall be fabricated from 3 mm thick photo luminescent rigid PVC or aluminum composite panel, minimum size 600 mm × 600 mm, with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 2.00 0.00
4.5 No smoking sign as per the detail Ar.drawing No 28.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.13-Day Works
1 LABOUR USD 0.00
2 MATERIAL USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
(ALL PROVISIONAL)
In accordance with the Conditions of Contract, the Contractor will be paid day work rates for extra work that cannot properly be measured and valued, and the Contractor is to insert in the space provided below the basic rates and costs of labour,materials and plant as described hereunder:-
1.1 MASON hours 1 0.00
1.2 CARPENTER hours 1 0.00
1.3 SCAFFOLDER hours 1 0.00
1.4 JOINER hours 1 0.00
1.5 PLUMBER hours 1 0.00
1.6 ELECTRICIAN hours 1 0.00
1.7 PLASTERER hours 1 0.00
1.8 PAINTER hours 1 0.00
1.9 LABOURER hours 1 0.00
TOTAL in USD 0.00
1.10 To the basic net rates of labor used for work carried out on day works, an addition 25% percent which is to include for task work and incentive schemes, tools, standing, scaffolding, supervision, insurance, transport profit and overheads.
To collection of Labour Day works 0.00
2.1 Cement Per Tonne 1 0.00
2.3 Aggregate (grade 25 - 5mm) m3 14 0.00
2.4 Steel reinforcement
(i) Mild steel bar Kg 1 0.00
(ii) High tensile bar Kg 1 0.00
2.5 Timber formwork Per SQ.M 1 0.00
2.6 Paint, Gloss Per 4 Litres 1 0.00
2.7 Paint, Emulsion Per 4 Litres 1 0.00
2.8 Mahogany Varnish Per 4 Litres 1 0.00
2.9 100mm diameter uPVC rainwater downpipe 6M Per Each 1 0.00
2.10 Ditto bends Per Each 1 0.00
2.11 Ditto offsets Per Each 1 0.00
2.12 Ditto watershoe Per Each 1 0.00
2.13 Fixing brackets Per Each 1 0.00
2.14 Fixing screws Per Packet 1 0.00
2.15 75mm thick x 375mm wide weather/throated cills Per M 1 0.00
2.16 4 mm Clear sheet glass Per SQ.M. 1 0.00
2.17 100mm long Flush bolt Per Each 1 0.00
2.18 Indicator Signage Per Each 1 0.00
2.19 400mm x 200mm x 100mm hollow concrete blocks Per 1000 1 0.00
2.20 300mm x300mm x 8mm Ceramic floor tiles Per SQ.M. 1 0.00
2.21 150mm x 150mm x 6mm white glazed wall tiles Per SQ.M. 1 0.00
2.22 25mm x 3mm earth copper tape Per M 1 0.00
2.23 35mmsq bare copper cable Per M 1 0.00
2.24 6mmsq bare copper cable Per M 1 0.00
2.25 2.5mmsq. TWE copper cable Per M 1 0.00
2.26 2.5mmsq. SC PVC-I copper cable Per M 1 0.00
2.27 4.0mmsq. SC PVC-I copper cable Per M 1 0.00
2.28 10.0mmsq. 3C PVC-SWA-PVC copper cable Per M 1 0.00
2.29 20mm diameter galvanised steel tubing 6M Per M 1 0.00
2.30 20mm diameter galvanised steel tee Per Each 1 0.00
2.31 20-15mm diameter reducer Per Each 1 0.00
2.32 110mm diameter uPVC soil pipe 6M Per Each 1 0.00
2.33 50mm ditto waste pipe 6M Per Each 1 0.00
2.34 110mm ditto single branch access Per Each 1 0.00
2.35 50mm ditto sweep tee Per Each 1 0.00
2.36 Single bowl, single drainer stainless steel sink size 2000 x 600mm Per Each 1 0.00
To Collection 0.00
2.37 To the basic nett rates of materials used for work carried out on dayworks, an addition of 25% which is to include for unloading and storing as necessary, the use of hand plant, and machinery etc. available on site, profit and overheads.
To collection of Material Day works 0.00
3.1 Portable Compressor with 2 breakers or equivalent with 1500 mm hoses and reels hours 40 0.00
3.2 Damp Truck (0.75 tonne) hours 40 0.00
3.3 Lorry seven tonne tipper hours 40 0.00
3.4 Concrete Mixer (14/10) complete for weight batch mixing hours 40 0.00
3.5 50 mm self priming centrifugal pump with hose and ancillary equipment hours 40 0.00
3.6 Concrete Vibrators hours 40 0.00
To Collection 0.00
3.7 To the basic rates of plant used for work carried out on dayworks, an addition of 25% per cent, which is to include for driver and/or attendance, fuel and consumable stores supervision, insurance, road licence,profit and overheads.
To collection of Plant Day works 0.00
Name of Signatory:
United Nations Office for Project Services
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
Tender Reference:
ENHANCING FOOD SECURITY & RESILIENCE OF RURAL COMMUNITIES (EFSR),
CONSTRUCTION WORKS FOR MODEL CROP & VEGETABLE MARKET PROJECT
BILL OF QUANTITIES (BOQ)
- Bill Nr.1 - Mobilization
- Bill Nr.2 to 12-Civil, Electrical & Sanitary Works-BoQ
- Bill Nr.13 - Day Works
NOTE: It is a MANDATORY requirement for bidders to complete and return both this excel BOQs and their respective duly signed pdf for further reference
Failure to complete all sections of the BOQ may result to automatic disqualification of your bid.
September, 2026
PREAMBLE TO BILLS OF QUANTITIES
1 Priliminary Condition
1.1 This Specification shall be read in conjunction with the Particular Technical Specifications provided under each work discipline, as well as the latest edition of the Sudan Standard Technical Specifications for Building Works, or any other internationally recognized standards commonly adopted in Sudan.
1.2 The Bill of Quantities (BoQ) shall be measured in accordance with the latest edition of the Sudan Standard Methods of Measurement for Building Works.Pro Memoria (PM): Indicates that the cost of the item is deemed to be included and distributed within other related work items in the BoQ. No separate payment will be made.Lump Sum (LS): Indicates that the item is priced as a fixed total amount, with no adjustment or variation permitted to the total price regardless of actual quantities executed.
1.3 The contractor has fully understood the scope of works by minutely having studied the drawings and Bill of Quantities with specifications, and by having visited the site. He will, on his own initiative and before the works start and in his best ability, notify the consultant of works which are not mentioned in the BoQ and/or the specifications and/or the drawings, which are necessary to execute the construction as envisioned in the drawings. Thus, after the works have started, the contractor cannot rely on incompletions in the consultants' work to make claims of any kind. Indeed, the contractor will add upon the specifications according to his own insight and professional experience. If there are works to be done which are not specified in this BoQ, it is up to the consultant to decide wether these works are variation works which need change orders, or wether these works are included in the items and their prices in the BoQ.
1.4 The contractor has to execute all works which have a direct or indirect impact on safety and availability of infrastructure (water, sewage, electricity, …) in as short a period as feasible.
1.5 The contractor will secure the structural and functional integrity of the exsiting buildings nearby the project site during construction work as well as of the building’s surroundings such as but not limited to public road, gate, lawn. He will study and execute the necessary scaffolding to support the building, in order to avoid any cracks, settlements, or crumbling. This scaffolding to support the building during the works are included in the prices given. Debris will be cart away to certified debris places in the area. In no way, debris will be stored, buried or burned on site.
1.6 After the works, the contractor will do a thorough cleaning of the construction site, this means cleaning of all excess mortars, cement bags, excess blockwork, excess tile jointing – in short any construction remnant which hinders the proper use of the house upon site hand-over.
1.7 In general the contractor will put his professional experience and craftsmanship to work, in order to get a holistically well-constructed building, to the highest and most up-to-date standards of Sudan Construction Culture.
2 Organisation of Construction Site
This includes all necessary preparations to execute the works; at least from the beginning until the end of the works; according to the best knowledge and experience of the contractor: at least conform local standards.
The objectives of the Bill of Quantities are
(a) to provide sufficient information on the quantities of Works to be performed to enable bids to be prepared efficiently and accurately; and
(b) when a Contract has been entered into, to provide a priced Bill of Quantities for use in the periodic valuation of Works executed.
In order to attain these objectives, Works have been itemized in the Bill of Quantities in sufficient detail to distinguish between the different classes of Works, or between Works of the same nature carried out in differently or in other circumstances which may give rise to different considerations of cost.
4 The Bills of Quantities for the Works comprise the following:
Preamble to Bill of Quantities
List of principal Quantities
Bill Nr. 1 Mobilization
Bill Nr. 2 - 12 Civil, Electrical Installation & Sanitary Installation
Bill Nr. 13 Day Works
5 The Contractor’s unit rates in these bills are to cover supplying of materials, taking delivery, transporting, loading and off loading inspection, storage, stacking, landing, preparation, installation including provision of all labour, requirement false work, temporary support, surface preparation and testing of the works. The rates shall include all applicable taxes and duty. The cost of testing of the materials to be used in the works unless otherwise provided is to be included in the rates of the respective Bill items.
6 Measurement for payment shall be for the complete installation and having passed all necessary tests.
7 Work shall not be executed on a Day work basis unless ordered in writing by the Consultant on approval by the Employer. The rates entered in the Day works Bill of Quantities shall apply to any quantity of Day work instructed by the Consultant. Nominal quantities have been indicated against each item to permit the extended total to be carried forward to the Grand Summary.
8 “Rates and prices shall be inserted in the rate and total columns of the Bill of Quantities in USD
9 Bills of Quantities are to be read in conjunction with the Instructions to Bidders, the Conditions of Contract Data, the Specifications and the Drawings. The quantities stated against each item in the Bills of Quantities, with the exception of those items specifically marked ‘sum’, are the estimated quantities of the Work to be executed by the Contractor in fulfillment of his obligations under the Contract.
10 The Contractor is required to check the number of the pages and should any be found to be missing or in duplicate he must inform the Engineer at once and have the same rectified.
11 No liability whatever will be admitted or claim allowed in respect of errors in the Contractor’s tender due to mistakes in the Bills of Quantities which should have been rectified in the manner described above.
12 The contractor shall not alter or otherwise qualify the text of these Bills of Quantities. Any alteration or qualification made without authority will be ignored and the text of the Bills of Quantities as printed will be adhered to.
13 Each item in the Bills of Quantities is to be priced. If any items are left un-priced it will be assumed that the value of the work described there under is elsewhere allowed for. The prices and rates to be inserted in the Bills of Quantities are to be fully inclusive of all costs and expenses which may be required for the construction of the work described, together with general risks, liabilities and obligations set forth or implied in these documents.
14 In no case will any claim for expenses incurred by the Contractor in preparation of this Tender be allowed.
15 The Contractor is solely responsible for the accurate ordering of materials in accordance with the Specifications, Drawings and Engineer’s Instructions and no claim for any loss or expense will be entertained for orders for materials based on the Bills of Quantities.
16 The quantities given in the Bills of Quantities are estimated and no claim by the Contractor for the final quantities being larger or smaller than the quantities given in the Bills of Quantities will be permitted except alows in accordance with the particular of the Conditions of Contract.
17 The term ‘provide’ or ‘supply’ used for any item shall be deemed to include transport to site, handling, storage and fixing complete, and the Bidder’s rate shall include for this.
18 The following abbreviations have been used in the Bills of Quantities:-
ml metre linear
m2 square metre
PS provisional Sum
Set Complete set of work with accessories & components
lot Complete set of work with accessories & components
PS provisional Sum
USD United States Dollar
uPVC un-plasticized poly vinyl chloride
HDPE high density polyethylene
GMS galvanized mild steel
PPE personal protective equipment
ASTM American society for testing & material
GW well-graded gravel
GP poorly-graded gravel
GM silty gravel, gravel-sand-silt mixtures
GC Clayey gravels, gravel sand-clay mixtures
SW well graded sands
SP poorly graded sands
SM silty sand, sand -silt-mixtures
SC clayey sands, sand-clay mixtures
AASHO American Association of State Highway and Transportation Officials,
ACI American Concrete Institue
RHS rectangular hollow section
PVD Physical Vapor Deposition
HCB hollow concret block
CBR california bearing ratio
MC medium curing
SDB sub distribution board
PDB pump distrbution board
20 Unless otherwise provided there are no separate measurement items for Contractual requirements. The Contractor is deemed to have included his costs for the Contractual requirement
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILIENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
ALL BILLS SUMMARY Amount in USD
1 Bill Nr.1 - Mobilization USD 0.00
2 Bill Nr.2 -Crop Market Building-
2.1 - Civil Work USD 0.00
2.2 - Electrical Installation Work USD 0.00
3 Bill Nr.3 -Vegetable Market Building-
3.1 - Civil Work USD 0.00
3.2 - Electrical Installation Work USD 0.00
3.3 - Crop & Vegetable Sanitary Installation Work USD 0.00
4 Bill Nr.4 -Multi-Purpose Hall Building-
4.1 - Civil Work USD 0.00
4.2 - Electrical Installation Work USD 0.00
4.3 - Sanitary Installation Work USD 0.00
5 Bill Nr.5 -Security/Guard House Building-
5.1 - Civil Work- For Two (2) Unit USD 0.00
5.2 - Electrical Installation Work- For Two (2) Unit USD 0.00
5.3 - Sanitary Installation Work- For Two (2) Unit USD 0.00
6 Bill Nr.6 -Toilet Building With Pit Laterin-
6.1 - Civil Work-Fot Two (2) Unit USD 0.00
6.2 - Electrical Installation Work-Fot Two (2) Unit USD 0.00
6.3 - Sanitary Installation Work-Fot Two (2) Unit USD 0.00
7 Bill Nr.7 Pump Control Swith Shed with Water Tanker Seat
7.1 - Civil Work for Two (2) Unit USD 0.00
7.2.1 - Electrical Installation Work Pump House-1 USD 0.00
7.2.2 - Electrical Installation Work Pump House-2 USD 0.00
8 Bill Nr.8 Solid Waste Collection-Civil Work USD 0.00
9 Bill Nr.9 Site Works-Civil USD 0.00
10 Bill Nr.10 Site Work-Electrical USD 0.00
11 Bill Nr.11-Site Works-Sanitary USD 0.00
12 Bill Nr.12 Signage USD 0.00
GRAND TOTAL USD 0.00
13 Bill Nr.13 - Day Works USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILIENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill Nr. 1- Mobilization
1 SIGN BOARD USD 0.00
2 SITE SUPERVISOR TRANSPORTATION USD 0.00
3 SAFTEY HARNESS & PROTECTION USD 0.00
4 SAFTEY & SECURITY OF WORKS USD 0.00
5 SHOP DRAWINGS USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 Contractor to provide a Project Identification sign size (200 cm × 200 cm), Contractor to submit shop drawing for UNOPS Engineer Approval, also 2 safety signs (120 cm x 120 cm). Safety signed to be submitted to approval of Engineers. LS 1.00 0.00
2 Site Supervisor Office & Transportation
2.1 Providing office for supervisor team completed with office Desk LS 1.00 0.00
3 Safety Harness and Protection
3.1 2 No (Minimum) Safety Harness with lanyards , 3 fire powder 6Kg fire extinguishers, and selection of gloves & safety glasses to be kept in UNOPS Office at all time, also contractor should in his price include the cost of providing all his staff and work force with suitable PPEs ( i.e. Hard Hat, Safety Boot, Dust Masks, Safety Vests and Safety Glasses) LS 1.00 0.00
4 Safety & Security of Works
4.1 Allow for providing safety and security for the Works and material as per the requirement laid under the Contract, including security lighting, lockable or open material storage areas, engaging security guards and / or any other measures as necessary. Cost shall include Road Safety awareness, and public traffic flow management during construction. In case the project intervention is inside the existing operational compound and accordingly the contractor shall make all the necessary planning on Contractor Safety, Security, and Operational Continuity Protocol ensures that construction works are performed without disrupting the existing business normal operations or compromising its safety and security. Contractors must strictly adhere to all guidelines, ensuring seamless coordination with the existing business management team & the consultant. Non-compliance may considered as a breach of the Contract. Contractor shall construct temporary fencing that separate the existing business and the construction site, safety access route and separate access. The contractor shall also indicated his methodology and work plan for the specific topics. LS 1.00 0.00
5 Shop Drawings
5.1 Allow for prepare and submit to the Engineer's Representative a complete set of Shop Drawings, as required to the specified scale(s), giving all details, as required by the Engineer's Representative, for the work executed. Submission shall be in 3 sets as hard copies, color printed on A1 size paper and 01 set of soft copies in AutoCAD compatible version in a compact disc. LS 1.00 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILIENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.1- Crop Market Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 1,706.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 853.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 685.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 251.00 0.00
1.5 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 89.00 0.00
1.6 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 1,272.00 0.00
1.7 Ditto as above item 1.5 but around isolated footing. m3 764.00 0.00
1.8 Ditto as above item 1.5 but around masonry foundation wall. m3 34.00 0.00
1.9 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 1,876.00 0.00
1.10 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 1,203.00 0.00
1.11 Supply and fix construction joint between grade beam & grade slab with 1 cm thick x 15cm wide chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance. ml 786.00 0.00
1.12 Ditto as above item 1.10 but construction joint between grade slab & grade slab where the slab area is larger. ml 125.00 0.00
1.13 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 340.00 0.00
2.1.2 Under masonry foundation wall m2 89.00 0.00
2.1.3 Under grade beam m2 109.00 0.00
2.1.4 Under slab on grade including ramp m2 1,203.00 0.00
2.1.5 Under masonry steps on grade m2 26.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 140.20 0.00
2.2.2 In foundation column. m3 26.00 0.00
2.2.3 In grade beams. m3 50.00 0.00
2.2.4 In ramp restrain beams. m3 1.20 0.00
2.2.5 In entrance steps. m3 6.20 0.00
2.2.6 In 15 cm thick ground floor slab including ramps & half part of open market. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing. m2 1,202.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 207.00 0.00
2.3.2 To foundation column m2 273.00 0.00
2.3.3 To grade beams & ramps edge m2 378.00 0.00
2.3.4 To ramp restrain beam m2 12.00 0.00
2.3.5 To entrance steps m2 80.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 8 mm deformed bar Kg 149.00 0.00
Dia 12 mm deformed bar Kg 2,577.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 1,208.00 0.00
Dia 16 mm deformed bar Kg 2,310.00 0.00
Dia 20 mm deformed bar Kg 2,269.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 1,665.00 0.00
Dia 16 mm deformed bar Kg 4,931.00 0.00
2.4.4 For ramp restrain beam
Dia 8 mm deformed bar Kg 37.00 0.00
Dia 12 mm deformed bar Kg 71.00 0.00
2.4.5 For entrance steps
Dia 8 mm deformed bar Kg 448.00 0.00
Dia 16 mm deformed bar Kg 208.00 0.00
2.4.6 For floor slab on grade, ramp slab & outdoor tratment slab
Dia 8 mm deformed bar Kg 377.00 0.00
Dia 10 mm deformed bar Kg 9,520.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 92.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 26.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 29.10 0.00
1.1.2 In intermidiate beams m3 32.50 0.00
1.1.3 In top tie beams m3 13.60 0.00
1.1.4 In internal partition wall tie beams m3 3.27 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 263.00 0.00
1.2.2 To intermidiate beams m2 314.00 0.00
1.2.3 To top tie beams m2 127.00 0.00
1.2.4 In internal partition wall tie beams m2 32.70 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 1,392.00 0.00
Dia 16 mm deformed bar Kg 636.00 0.00
Dia 20 mm deformed bar Kg 2,540.00 0.00
1.3.2 For intermidiate beam
Dia 8 mm deformed bar Kg 1,048.00 0.00
Dia 16 mm deformed bar Kg 3,281.00 0.00
1.3.3 For top tie beam
Dia 8 mm deformed bar Kg 483.00 0.00
Dia 16 mm deformed bar Kg 1,507.00 0.00
1.3.4 For tinternal partiton tie beam
Dia 8 mm deformed bar Kg 150.69 0.00
Dia 12 mm deformed bar Kg 290.38 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick. The bricks shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct both-side decorative face red burnt 20cm thick (double) brick wall, built in approved red burnt clay face bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, with exposed face brick finish on both sides complete in every respect m2 587.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 908.00 0.00
3.2 Ditto as above item 3.1 but gable side pre-painted 0.5mm thick EGA-500 wall clad fixed to RHS frame as shown in the structural drawing. m2 68.00 0.00
3.3 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet ridge cup at the roof slope direction changes. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of ridge cap: 80 cm. m.l. 32.00 0.00
3.4 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 126.00 0.00
3.5 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 63.00 0.00
Total carried to summary USD 0.00
4.1 Supply, fabricate and fix metal guard rail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 120 × 120 × 6 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 1000 mm above finished floor level; two horizontal balustrade rails CHS Ø20 × 2.5 mm welded to vertical RHS posts; top handrail CHS Ø50 × 2.5 mm welded continuously; infill: vertically spaced CHS Ø20 × 2.5 mm at c/c 100 mm between the two horizontal rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 99.50 0.00
4.2 Supply, fabricate and fix metal ramp & step handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 38.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect Pre-Engineerered structures steel as primary and secondary members & all other reuired accessories.The material standard and fabrication be according to applicable American, British or Europian codes and standards. The material shall be as per approved pre-engineered building sysem standard and shall include column, rafter & truss (Hot rolled and built up I-sections), purlin (Rectangular hollow section), Bracings (rod Bracings), Screws, high strength bolts, Machine Bolts,Anchor bolts, Plates and other accessories.
The system is designed for Corrosively Category C3 and Long Design Life (15+ years) in accordance with ISO 12944. Prefabrication Primer Apply one coat of zinc-rich epoxy primer to a dry film thickness (DFT) of 20-25 µm. shop Coating: After fabrication, clean welds and bolt holes and apply full epoxy intermediate coat to achieve a minimum total shop DFT of 75 µm
All structural steel members shall be protected with an approved, certificated; thin-film intumescent coating system to achieve a fire resistance rating of R60. The required Dry Film Thickness (DFT) for the minimum intumescent coating shall be 1200 µm
All damage to shop coatings incurred during transport and erection shall be cleaned and repaired to the original specification. After erection, apply a final coat of an approved Polyurethane (PU) Topcoat. The total system DFT for the full corrosion protection system (primer, intermediate and topcoat) shall be a minimum of 285 µm over the entire structure.
All are as per the detail structural drawing and specification.
A. Primary Structure
A.1 Supply, fabricate, deliver, and erect IPE 400 steel column , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 400mm, flage width 180mm, web thickness 8.60mm, flange thickness 13.50mm & unit weight kg/ml 66.30kg/ml kg 915.00 0.00
A.2 Supply, fabricate, deliver, and erect IPE 400 rafter , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 400mm, flage width 180mm, web thickness 8.60mm, flange thickness 13.50mm & unit weight kg/ml 66.30kg/ml kg 11,537.00 0.00
A.3 Supply, fabricate, deliver, and erect IPE 100 canopy truss , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 100mm, flage width 55mm, web thickness 4.10mm, flange thickness 5.70mm & unit weight kg/ml 8.10kg/ml kg 671.00 0.00
B. Secondary Structure
B.3 Supply, fabricate, deliver, and erect IPE 300 secondary beam , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 300mm, flage width 150mm, web thickness 7.10mm, flange thickness 10.50mm & unit weight kg/ml 42.20kg/ml kg 2,532.00 0.00
C. RHS Purlins 0.00
C.1 RHS 100 x 100 x 4mm purlin fixed to upper truss member with 100 x 100 x 3mm L= 60mm angle iron. Price include angle iron. Kg 12,913.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
D. RHS Gable side frame 0.00
D.1 RHS 30 x 30 x 3mm RHS frame for gable side EGA wall clad support Kg 387.00 0.00
A.1 IPE 400 column & concrete colomn connection plate size 560 x 360 x 20mm with 8 dia 22mm sloted holes. No 24.00 0.00
A.2 IPE 400 column & rafter connection plate size 180 x 822 x 10mm with 12 dia 18mm sloted holes. No 24.00 0.00
A.3 IPE 400 column & IPE 300 secondary beam connection plate size 200 x 155 x 10mm with 4 dia 18mm sloted holes. No 40.00 0.00
A.4 IPE 400 rafter & rafter connection plate at Apex size 180 x 844 x 10mm with 4 dia 18mm sloted holes. No 12.00 0.00
A.5 IPE 100 truss & concete wall mounted connection plate size 300 x 280 x 10mm with 8 M20 bolt sloted holes. No 48.00 0.00
A.6 Stiffner size 180-80 x 10mm No 48.00 0.00
B Bolt with nut
B.1 Anchor bolt with nut column connection with concrete column M20 grade 8.8 depth 300mm No 96.00 0.00
B.2 Anchor bolt with nut canopy truss with concrete column M20 grade 8.8 depth 450mm No 192.00 0.00
B.3 Bolt with nut for column with rafter connection M 16 grade 8.8 No 144.00 0.00
B.4 Bolt with nut for column with secondary beam connection M 16 grade 8.8 No 80.00 0.00
B.5 Bolt with nut for rafter with rafter at Apex connection M 16 grade 8.8 No 72.00 0.00
B.6 C1022 hex head Tek screw fixed to concrete beam No 56.00 0.00
C Tension Cable
Supply, fabricate and install tension cable bracing system for steel roof trusses, comprising T32 mm threaded tension rods/cables, turnbuckles, coupling nuts, paddle braces, gusset plates, suspension plates, clevises, anchor connections, bolts, nuts, washers and all necessary fittings, complete with tensioning, alignment and fixing in accordance with the structural drawing, approved shop drawings and Engineer's instructions. Ml 214.40 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply three coats of cement sand plaster (1:3) for exposed beam and column surfaces.The final coat shall be made with fine sand sieved through a 1.18 mm mesh. surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks m2 704.00 0.00
6.2 Rake out joints where required and execute pointing to stone masonry joint work using cement-sand mortar of specified mix, including cleaning joints, wetting surfaces, filling, finishing, curing, and all necessary labor, materials, tools, and incidentals, complete in accordance with the drawings and specifications. m2 52.00 0.00
6.3 Rake out joints where required and execute pointing to decorative red brick joint work using cement-sand mortar of specified mix, including cleaning joints, wetting surfaces, filling, finishing, curing, and all necessary labor, materials, tools, and incidentals, complete in accordance with the drawings and specifications. m2 1,174.00 0.00
6.4 Provide and lay 50 mm thick cement-sand screed flooring, finished with a smooth steel-trowelled surface, using cement and clean sand mixed in the specified proportion (1:3 or as specified), laid to the required levels, slopes, and falls, including surface preparation, mixing, placing, compacting, leveling, finishing, curing, and all labor, materials, tools, equipment, and incidentals necessary to complete the work in accordance with the drawings and specifications- for crop storage area. m2 444.00 0.00
6.5 Provide broom finish to freshly placed concrete carway, Pavmeny & ramp surface, including screeding, leveling, texturing the surface with a broom to produce a uniform non-slip finish, and all labor, tools, equipment, and incidentals necessary to complete the work in accordance with the specifications and Engineer's instructions. Concrete work measured separately. m2 878.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
7.1 Apply three coats of acrylic emulsion paint to exposed beam & column plastered wall surfaces. m2 704.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.2.2- Crop Market Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ELECTRICAL WORKS
1.1 DISTRIBUTION BOARDS 0.00
Flush-mounted sub distribution Board, SDB-CM in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1.1.1 1pc main MCB of 32A, 4P , Icu=10KA , coupled with RCD ,300mA, Type S/ Time delayed 0.00
10pcs RCBO of 16A, 2P, Icu=6KA ,30mA 0.00
6pcs MCB of 10A, 2P, Icu=6KA
2pcs MCB of 16A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A, 3ph+N No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 44.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W,4000K, 3600Lumen, CRI > 80, ceiling-mounted, polycarbonate, flicker-free, IP66, for outdoor instalation No 8.00 0.00
1.3.L2E LED battenLight: L1200mm, 30W, 3600 lumens, 4000K, CRI > 80, surface-mounted.High-impact polycarbonate housing and diffuser with minimum IP65 protection rating , & ~1000 lumens (emergency), 4000K, 90 minute operation, No 4.00 0.00
1.3.L4 LED Highbay , pendant ( truss mounted), D273,h 93mm, 100w, 13000Lumens, 6500K, CRI>80. Die-cast aluminum housing with a clear optical polycarbonate lens (IP65 / IK06 rated) and a 100° to 110° wide beam angle. Complete with integrated driver, suspension mounting hook/accessories, and hardware. No 20.00 0.00
1.3.(E) Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). IP65,IK08, 5700K, minimum 7W, autonomy 90min. Warranty: 3 years (components), 5 years (battery). No 8.00 0.00
1.3.(EX) Saftey only emergency with FLC 11SE or approved equivallent illuminated signage system shall be installed to give information with standard dimensions information displays and illumination level with double or single faces. The display consisting of symbols, text or figures supported with direction which will indicate EXIT, toilets (lady and gentlemen), staircases and floor level will be placed as indicated on the drawings throughout building for the convenience of the public and workers .The symbols, text or figures shall be choices of the client or engineer and shall be appropriate enough to describe the room, areas, services and all safety directions it should have emergency battery for at least 90min. No 4.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Flush-mounted thumbler switch in sheet steel enclosure with lockable door with 6pcs of 16A/1Ph two way tumbler switchs including all necessary fixing and connecting accessories No 2.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 30.00 0.00
1.6 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.6.1 16A ,1ph ,230V 2p+e Doublesocket outlet No 18.00 0.00
1.6.2 16A ,2P,230V 2p+e Doublesocket out let water proof for outdoor installation IP44. No 12.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.3.1- Vegetable Market Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 1,706.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 853.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 615.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 226.00 0.00
1.4 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 87.00 0.00
1.5 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 1,274.00 0.00
1.6 Ditto as above item 1.5 but around isolated footing. m3 680.00 0.00
1.7 Ditto as above item 1.5 but around masonry foundation wall. m3 33.00 0.00
1.8 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 1,895.00 0.00
1.9 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 1,213.00 0.00
1.10 Supply and fix construction joint between grade beam & grade slab with 1 cm thick x 15cm wide chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance. ml 645.00 0.00
1.11 Ditto as above item 1.10 but construction joint between grade slab & grade slab where the slab area is larger. ml 210.00 0.00
1.12 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 308.00 0.00
2.1.2 Under masonry foundation wall m2 79.00 0.00
2.1.3 Under grade beam m2 76.00 0.00
2.1.4 Under slab on grade including ramp m2 1,213.00 0.00
2.1.5 Under masonry steps on grade m2 26.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 132.00 0.00
2.2.2 In foundation column. m3 23.00 0.00
2.2.3 In grade beams. m3 40.00 0.00
2.2.4 In ramp restrain beams. m3 1.20 0.00
2.2.5 In entrance steps. m3 6.20 0.00
2.2.6 In 15 cm thick ground floor slab including ramps & half part of open market. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 1,213.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 187.00 0.00
2.3.2 To foundation column m2 236.00 0.00
2.3.3 To grade beams & ramps edge m2 296.00 0.00
2.3.4 To ramp restrain beam m2 12.00 0.00
2.3.5 To entrance steps m2 80.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 8 mm deformed bar Kg 124.00 0.00
Dia 12 mm deformed bar Kg 2,181.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 1,084.00 0.00
Dia 16 mm deformed bar Kg 1,770.00 0.00
Dia 20 mm deformed bar Kg 2,269.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 1,286.00 0.00
Dia 16 mm deformed bar Kg 3,783.00 0.00
2.4.4 For ramp restrain beam
Dia 8 mm deformed bar Kg 37.00 0.00
Dia 12 mm deformed bar Kg 71.00 0.00
2.4.5 For entrance steps
Dia 8 mm deformed bar Kg 448.00 0.00
Dia 16 mm deformed bar Kg 208.00 0.00
2.4.6 For floor slab on grade, ramp slab & outdoor tratment slab
Dia 8 mm deformed bar Kg 377.00 0.00
Dia 10 mm deformed bar Kg 9,488.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 87.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 26.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 29.10 0.00
1.1.2 In intermidiate beams m3 32.50 0.00
1.1.3 In top tie beams m3 13.60 0.00
1.1.4 In internal partition wall tie beams m3 2.16 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 232.00 0.00
1.2.2 To intermidiate beams m2 217.00 0.00
1.2.3 To top tie beams m2 127.00 0.00
1.2.4 In internal partition wall tie beams m2 21.60 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 1,288.00 0.00
Dia 16 mm deformed bar Kg 318.00 0.00
Dia 20 mm deformed bar Kg 2,540.00 0.00
1.3.2 For intermidiate beam
Dia 8 mm deformed bar Kg 693.00 0.00
Dia 16 mm deformed bar Kg 2,186.00 0.00
1.3.3 For top tie beam
Dia 8 mm deformed bar Kg 483.00 0.00
Dia 16 mm deformed bar Kg 1,507.00 0.00
1.3.4 For tinternal partiton tie beam
Dia 8 mm deformed bar Kg 99.54 0.00
Dia 12 mm deformed bar Kg 191.81 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct both-side decorative face red burnt 20cm thick (double) brick wall, built in approved red burnt clay face bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, with exposed face brick finish on both sides complete in every respect m2 677.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 909.00 0.00
3.2 Ditto as above item 3.1 but gable side pre-painted 0.5mm thick EGA-500 wall clad fixed to RHS frame as shown in the structural drawing. m2 68.00 0.00
3.3 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet ridge cup at the roof slope direction changes. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of ridge cap: 80 cm. m.l. 32.00 0.00
3.4 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 126.00 0.00
3.5 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 63.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors all as per the drawing. Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint.
D2 size 170cm x 260cm no 12.00 0.00
4.2 Supply, fabricate and fix metal guard rail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 120 × 120 × 6 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 1000 mm above finished floor level; two horizontal balustrade rails CHS Ø20 × 2.5 mm welded to vertical RHS posts; top handrail CHS Ø50 × 2.5 mm welded continuously; infill: vertically spaced CHS Ø20 × 2.5 mm at c/c 100 mm between the two horizontal rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 99.50 0.00
4.3 Supply, fabricate and fix metal ramp & step handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 38.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect Pre-Engineerered structures steel as primary and secondary members & all other reuired accessories.The material standard and fabrication be according to applicable American, British or Europian codes and standards. The material shall be as per approved pre-engineered building sysem standard and shall include column, rafter & truss (Hot rolled and built up I-sections), purlin (Rectangular hollow section), Bracings (rod Bracings), Screws, high strength bolts, Machine Bolts,Anchor bolts, Plates and other accessories.
The system is designed for Corrosively Category C3 and Long Design Life (15+ years) in accordance with ISO 12944. Prefabrication Primer Apply one coat of zinc-rich epoxy primer to a dry film thickness (DFT) of 20-25 µm. shop Coating: After fabrication, clean welds and bolt holes and apply full epoxy intermediate coat to achieve a minimum total shop DFT of 75 µm
All structural steel members shall be protected with an approved, certificated; thin-film intumescent coating system to achieve a fire resistance rating of R60. The required Dry Film Thickness (DFT) for the minimum intumescent coating shall be 1200 µm
All damage to shop coatings incurred during transport and erection shall be cleaned and repaired to the original specification. After erection, apply a final coat of an approved Polyurethane (PU) Topcoat. The total system DFT for the full corrosion protection system (primer, intermediate and topcoat) shall be a minimum of 285 µm over the entire structure.
All are as per the detail structural drawing and specification.
A. Primary Structure
A.1 Supply, fabricate, deliver, and erect IPE 400 steel column , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 400mm, flage width 180mm, web thickness 8.60mm, flange thickness 13.50mm & unit weight kg/ml 66.30kg/ml kg 915.00 0.00
A.2 Supply, fabricate, deliver, and erect IPE 400 rafter , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 400mm, flage width 180mm, web thickness 8.60mm, flange thickness 13.50mm & unit weight kg/ml 66.30kg/ml kg 11,537.00 0.00
A.3 Supply, fabricate, deliver, and erect IPE 100 canopy truss , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 100mm, flage width 55mm, web thickness 4.10mm, flange thickness 5.70mm & unit weight kg/ml 8.10kg/ml kg 671.00 0.00
B. Secondary Structure
B.3 Supply, fabricate, deliver, and erect IPE 300 secondary beam , including cutting, drilling, welding, bolting, lifting, alignment, temporary bracing, connection plates, gusset plates, stiffeners, anchor bolts where specified, surface preparation, one coat shop primer and two coats approved protective paint, and all labor, materials, tools, equipment, transportation, and incidentals required for complete installation in accordance with the structural drawings and specifications.( Plates & bolt measured elswhere). Section detail:Web depth 300mm, flage width 150mm, web thickness 7.10mm, flange thickness 10.50mm & unit weight kg/ml 42.20kg/ml kg 2,532.00 0.00
C. RHS Purlins 0.00
C.1 RHS 100 x 100 x 4mm purlin fixed to upper truss member with 100 x 100 x 3mm L= 60mm angle iron. Price include angle iron. Kg 12,913.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
D. RHS Gable side frame 0.00
D.1 RHS 30 x 30 x 3mm RHS frame for gable side EGA wall clad support Kg 387.00 0.00
A.1 IPE 400 column & concrete colomn connection plate size 560 x 360 x 20mm with 8 dia 22mm sloted holes. No 24.00 0.00
A.2 IPE 400 column & rafter connection plate size 180 x 822 x 10mm with 12 dia 18mm sloted holes. No 24.00 0.00
A.3 IPE 400 column & IPE 300 secondary beam connection plate size 200 x 155 x 10mm with 4 dia 18mm sloted holes. No 40.00 0.00
A.4 IPE 400 rafter & rafter connection plate at Apex size 180 x 844 x 10mm with 4 dia 18mm sloted holes. No 12.00 0.00
A.5 IPE 100 truss & concete wall mounted connection plate size 200 x 200 x 10mm with 4 dia 14mm sloted holes. No 48.00 0.00
A.6 Stiffner size 180-80 x 10mm No 48.00 0.00
B Bolt with nut
B.1 Anchor bolt with nut column connection with concrete column M20 grade 8.8 depth 300mm No 96.00 0.00
B.2 Anchor bolt with nut canopy truss with concrete column M20 grade 8.8 depth 450mm No 192.00 0.00
B.3 Bolt with nut for column with rafter connection M 16 grade 8.8 No 144.00 0.00
B.4 Bolt with nut for column with secondary beam connection M 16 grade 8.8 No 80.00 0.00
B.5 Bolt with nut for rafter with rafter at Apex connection M 16 grade 8.8 No 72.00 0.00
B.6 C1022 hex head Tek screw fixed to concrete beam No 56.00 0.00
C Tension Cable
Supply, fabricate and install tension cable bracing system for steel roof trusses, comprising T32 mm threaded tension rods/cables, turnbuckles, coupling nuts, paddle braces, gusset plates, suspension plates, clevises, anchor connections, bolts, nuts, washers and all necessary fittings, complete with tensioning, alignment and fixing in accordance with the structural drawing, approved shop drawings and Engineer's instructions. Ml 214.40 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply three coats of cement sand plaster (1:3) for exposed beam and column surfaces.The final coat shall be made with fine sand sieved through a 1.18 mm mesh. surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks m2 576.00 0.00
6.2 Rake out joints where required and execute pointing to stone masonry joint work using cement-sand mortar of specified mix, including cleaning joints, wetting surfaces, filling, finishing, curing, and all necessary labor, materials, tools, and incidentals, complete in accordance with the drawings and specifications. m2 51.00 0.00
6.3 Rake out joints where required and execute pointing to decorative red brick joint work using cement-sand mortar of specified mix, including cleaning joints, wetting surfaces, filling, finishing, curing, and all necessary labor, materials, tools, and incidentals, complete in accordance with the drawings and specifications. m2 1,354.00 0.00
6.4 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect.for vegitable market. m2 299.00 0.00
6.5 10cm high 1cm thick chamfered ceramic skirting of matching color to floor tiles. ml 82.00 0.00
6.6 Provide and lay 50 mm thick cement-sand screed flooring, finished with a smooth steel-trowelled surface, using cement and clean sand mixed in the specified proportion (1:3 or as specified), laid to the required levels, slopes, and falls, including surface preparation, mixing, placing, compacting, leveling, finishing, curing, and all labor, materials, tools, equipment, and incidentals necessary to complete the work in accordance with the drawings and specifications for vegitable store m2 138.00 0.00
6.7 Provide broom finish to freshly placed concrete carway, Pavmeny & ramp surface, including screeding, leveling, texturing the surface with a broom to produce a uniform non-slip finish, and all labor, tools, equipment, and incidentals necessary to complete the work in accordance with the specifications and Engineer's instructions. Concrete work measured separately. m2 917.00 0.00
6.8 Supply and fix concrete copping for short wall . Price shall include cement sand mortar bed and cement grouting. ml 70.00 0.00
6.9 Construct Vegetable Display Raised Suspended Floor – comprising raised display platform formed with 50mm thick precast reinforced concrete slabs (1000 × 1200mm), supported on 100mm thick concrete block piers/walls at spacing and arrangement shown on the drawings; including under-display storage space complete with LTZ frame and 30 × 38mm steel louvered doors; 300 × 300 × 8.5mm ceramic floor/wall tiles fixed to the precast concrete top surface including adhesive, grout and all necessary cutting; complete with reinforcement, concrete block supports, fixing accessories, finishing, cleaning, and all incidental works necessary for a complete installation in accordance with the drawings and specifications. One unit covers 37.45m2 and we have 4 unit in total. Ls 1.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
7.1 Apply three coats of acrylic emulsion paint to exposed beam & column plastered wall surfaces. m2 576.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.3.2- Vegetable Market Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ELECTRICAL WORKS
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Flush-mounted sub distribution Board, SDB-VM in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 40A, 4P , Icu=10KA, coupled with RCD ,300mA Type S/ Time delayed 0.00
18pcs RCBO of 16A, 2P, Icu=6KA ,30mA 0.00
6pcs MCB of 10A, 2P, Icu=6KA
2pcs MCB of 16A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A, 3ph+N No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 44.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W,4000K, 3600Lumen, CRI > 80, ceiling-mounted, polycarbonate, flicker-free, IP66, for outdoor instalation No 9.00 0.00
1.3.L2E LED battenLight: L1200mm, 30W, 3600 lumens, 4000K, CRI > 80, surface-mounted.High-impact polycarbonate housing and diffuser with minimum IP65 protection rating , & ~1000 lumens (emergency), 4000K, 90 minute operation, No 3.00 0.00
1.3.L4 LED Highbay , pendant ( truss mounted), D273,h 93mm, 100w, 13000Lumens, 6500K, CRI>80. Die-cast aluminum housing with a clear optical polycarbonate lens (IP65 / IK06 rated) and a 100° to 110° wide beam angle. Complete with integrated driver, suspension mounting hook/accessories, and hardware. No 20.00 0.00
1.3.(E) Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). IP65,IK08, 5700K, minimum 7W, autonomy 90min. Warranty: 3 years (components), 5 years (battery). No 8.00 0.00
1.3.(EX) Saftey only emergency with FLC 11SE or approved equivallent illuminated signage system shall be installed to give information with standard dimensions information displays and illumination level with double or single faces. The display consisting of symbols, text or figures supported with direction which will indicate EXIT, toilets (lady and gentlemen), staircases and floor level will be placed as indicated on the drawings throughout building for the convenience of the public and workers .The symbols, text or figures shall be choices of the client or engineer and shall be appropriate enough to describe the room, areas, services and all safety directions it should have emergency battery for at least 2 hours . No 4.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Flush-mounted thumbler switch in sheet steel enclosure with lockable door with 6pcs of 16A/1Ph two way tumbler switchs including all necessary fixing and connecting accessories No 2.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 44.00 0.00
1.6 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.6.1 16A ,2P,230V 2p+e Doublesocket out let No 32.00 0.00
1.6.2 16A ,2P,230V 2p+e Doublesocket out let water proof for outdoor installation IP44. No 12.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.3.3- Crop & Vegetable Market Building-Sanitary
1 ROOF RAIN WATER DOWN PIPING SYSTEM USD 0.00
2 FIR FIGHTING SYSTEM USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ROOF RAIN WATER DOWN PIPING SYSTEM
1.1 Rainwater Downpipe DN 100 (Market Block) – Supply, install, test, and commission one uPVC rainwater downpipe, DN 100 mm nominal diameter, conforming to ISO 1452-1 or AS/NZS 1260, minimum wall thickness 2.5 mm. Include stainless steel leaf guard (5 mm mesh) at roof inlet, galvanized pipe brackets (vertical spacing 1.8 m maximum, horizontal spacing 1.0 m maximum), UV-reflective light-colored oil paint coating (white/light grey) conforming to ISO 4892-2 on all exposed sections, and discharge splash block at base. Complete from roof outlet to ditch/splash block. ml 290.00 0.00
1.2 Horizontal extension (sprout) from roof downpipe – 100mm diameter uPVC (or specified approved equivalent material), including bends, sockets, clips/supports at 1.0m intervals, and end outlet to ditch. Extend from downpipe discharge point to nearest ditch location as directed on site. Ensure minimum continuous fall of 1:100 towards ditch. All joints watertight. ml 145.00 0.00
Total carried to summary USD 0.00
2 FIR FIGHTING SYSTEM
2.1 Supply, install, test, and commission approved quality automatic fire water pump set (electric pump, diesel driven pump, and jockey pump) on common heavy-duty steel base plate (hot-dip galvanized, anti-vibration mounts) complete with all accessories, piping, valves, instrumentation, controls, civil works, testing, commissioning, training, and documentation as specified herein. 1.0 Single NFPA 20 Design Basis: The fire pump system shall be designed, supplied, and installed as a single integrated NFPA 20 system comprising electric duty pump, diesel standby pump, and jockey pump on a common skid. The design shall be based on a single hydraulic duty point: 200 GPM (12.62 L/s) @ 82 m head (119 psi). All components shall be selected and matched to this single design basis. The system shall be factory-tested as a complete assembly to verify performance at rated flow, shutoff, and 150% of rated flow. A certified pump performance curve shall be provided showing Head vs. Flow, Efficiency, Power (BHP), and NPSHR, with the operating design point clearly marked at 200 GPM @ 119 psi. 2.0 Pump Specifications: Referenced Aurora 2-384-11 @ 2,950 RPM or equivalent approved for the design duty point: Electric Pump (Primary Duty): 200 GPM (12.62 L/s) @ 149 psi (10.3 bar / 103 m) [exceeds design head of 119 psi], 30 hp (22.4 kW), 400 V / 50 Hz / 3-phase, TEFC motor, with minimum 85% efficiency. Diesel Standby Pump: 200 GPM (12.62 L/s) @ 149 psi (10.3 bar / 103 m), diesel engine rated at 33 bhp (24.6 kW) minimum (includes 10% NFPA 20 safety factor over pump BHP), radiator-cooled, 24 V electric start, with automatic battery charger and two (2) 120 Ah batteries. Jockey Pump (Pressure Maintenance): 15 GPM (0.95 L/s) @ 90 m head (123 psi), 0.75 kW (1 hp), 400 V / 50 Hz / three-phase.The electric fire pump controller shall be provided with a Soft Starter type starter suitable for the 22.4 kW (30 hp), 400 V, 3-phase, 50 Hz motor, to provide controlled acceleration, limit inrush current, and minimize mechanical shock to the pump and piping system. The soft starter shall comply with IEC 60947-4-2 (BS EN 60947-4-2), be listed for fire pump service, and include a bypass contactor for full-load operation. 3.0 Pump Performance Curve: The supplier shall provide a certified pump performance curve for the complete pump set showing the following: (i) Head vs. Flow curve (in m and GPM) from shutoff to 150% of rated flow; (ii) Efficiency curve (percentage) across the full operating range; (iii) Power curve (BHP/kW) for both electric and diesel drivers; (iv) Net Positive Suction Head Required (NPSHR) curve; (v) Operating point clearly marked at 200 GPM @ 149 psi. The curve shall be certified by the manufacturer and submitted with the equipment. 4.0 Skid Assembly: Factory-assembled, tested, and mounted on common heavy-duty steel base plate (hot-dip galvanized, anti-vibration mounts, lifting lugs). Physical dimensions: 2,600 mm (L) × 1,500 mm (W) × 1,800 mm (H) nominal. Integrated diesel fuel tank (minimum 200 Liters capacity) incorporated within the skid base structure. The complete skid assembly shall be installed at 400 mm above the pump room finished floor level (FFL) on a purpose-built reinforced concrete plinth. 5.0 Piping and Valves: Common suction manifold (DN 150) and delivery manifold (DN 100) with flanged connections; suction gate valves; delivery check valves (silent type); delivery gate valves; pressure relief valve (set at 9.65 bar/140 psi); air release valves; stop/isolation valves; Y-type suction strainer with blow-down and differential pressure gauge; test valve with drain pipe; flow meter (electromagnetic type, DN 100 with digital display); 2-way test header (DN 80 with two DN 65 hose connections). Flexible pipe connections shall be provided at suction and discharge to isolate vibration and allow for thermal movement. 6.0 Instrumentation and Controls: NFPA 20 compliant controller with automatic/manual operation, addressable, compatible with electric and diesel pumps; pressure sensors with manometers; pressure gauges (0–16 bar range with siphons); flow switch with alarm; pressure switch integration (6.9 bar/100 psi start pressure, adjustable); alarms (pump running, phase failure, low suction, engine faults, battery failure, fuel low, leak detection, pump on automatic, power available); remote monitoring dry contacts; weekly test timer; IP54 enclosure. 7.0 Diesel Fuel Tank: Double-walled steel tank with leak detection interstitial space; minimum 200 Liters capacity (sized for 12 hours run time per NFPA 20 Section 11.4.1.3.1); mechanical fuel level gauge; lockable fill cap with spill basin; drain valve; vent pipe with flame arrestor; complete fuel supply piping (flexible hose, isolation valve, filter). The tank shall be integrated into the skid base structure at the bottom of the skid frame. 8.0 Exhaust System (Diesel Standby Pump): Flexible stainless steel connector; critical grade silencer; schedule 40 steel exhaust pipe with rain cap; heat insulation where accessible with galvanized supports. Exhaust pipe shall be routed through the roof with weatherproof penetration. 9.0 Civil Assistance Works: Reinforced concrete plinth (300 mm height above pump room FFL) with dimensions adequate to support the skid footprint (minimum 2,400 mm × 1,600 mm × 300 mm) constructed of 25 MPa reinforced concrete. Plinth shall include anchor bolts with templates, load-bearing capacity to support skid weight plus full water content and dynamic loads, finished surface with slope to drain, drainage channel at plinth perimeter, ventilation louvers for engine cooling and combustion air, wall/roof penetration sleeves with fire-resistant sealant, and finished floor sloped to drain. The raised plinth shall provide flood protection and facilitate maintenance access to the skid unit. 10.0 Testing and Commissioning: Pressure testing (1.5 MPa/15 bar for 2 hours, no leakage); flow testing (rated flow and churn); diesel engine 1-hour full load run test; battery load test; full system commissioning as per NFPA 20. The complete skid assembly shall be tested as a single integrated unit to verify performance against the certified pump curve. 11.0 Documentation: Manufacturer's certificates; certified pump performance curves (Head vs. Flow, Efficiency, Power, NPSHR); driver kW ratings for electric motor (22.4 kW/30 hp) and diesel engine (33 bhp/24.6 kW minimum); controller specifications with wiring diagrams; NFPA 20 compliance documentation; test reports; commissioning report; warranties (12 months); O&M manuals (English/Arabic); as-built drawings; spare parts list; site training (2 days, 4 persons). 12.0 Compliance and Certification: NFPA 20 (latest edition); UL Listed / FM Approved (or equivalent) for fire protection service. Reference Brand/Model: Approved manufacturer's EDJ Series Fire Pump Skid (End Suction, Electric + Diesel + Jockey, 200 GPM @ 149 psi configuration) or approved equivalent. 13.0 Electrical Power Supply Requirements: The electrical supply shall be designed to support the fire pump system with the following connected loads: Main fire pump motor: 22.4 kW (30 hp), 400 V / 3-phase / 50 Hz, 45 A full load current; Jockey pump motor: 0.75 kW (1 hp), 400 V / 3-phase / 50 Hz, 2.0 A; Electric motor controller: 0.50 kW, 400 V / 3-phase / 50 Hz, 1.5 A; Diesel engine controller: 0.30 kW, 230 V / single-phase, 2.5 A; Battery charger (diesel): 0.30 kW, 230 V / single-phase, 1.5 A. Total connected load (electric): 23.65 kW. A dedicated 100 A, 3-phase circuit breaker. Notes: All works in accordance with manufacturer's instructions and locations shown on drawings. Price includes all necessary accessories required for proper operation but not specified or shown. Final physical dimensions to be confirmed by selected manufacturer. The raised plinth (300 mm above FFL) shall be constructed prior to skid installation. The single NFPA 20 design basis shall be documented with the certified pump curve, driver kW ratings, and controller specifications submitted as part of the equipment supply. SET 1.00 0.00
2.2 Supply, install, test, and commission fire water piping from GRP water tank fire reserve compartment to four (4) Class II hose reel cabinets, complete with DN 80 (3 inch) Schedule 40 black steel main pipe (ASTM A53 Grade B), DN 50 (2 inch) Schedule 40 branch pipes, all necessary fittings (90° and 45° elbows, tees, reducers), DN80 PN16 gate valves (bronze, rising stem) at tank outlet and pump discharge, DN50 PN16 gate valves at each hose reel branch (4 units), DN80 swing check valve at pump discharge, pressure gauge (0–200 psi) with siphon and isolation valve, 2-way test header with 65 mm hose connections, expansion joints (as required), galvanized steel pipe supports and hangers spaced per NFPA 14 Table 10.6.3.2.1, threaded or grooved joints (no welding unless specified), underground section (500 mm cover, sand bedding, anti-corrosion PET/bituminous wrap), exposed section with two coats of red epoxy fire-resistant paint (150 µm DFT, Sa 2.5 surface preparation), and clear labeling in English and Arabic (red bands/stickers at 10 m intervals stating "FIRE MAIN – HOSE REEL SYSTEM"). Pipe routing to cover total length of 150 meters (the unit price shal include fittings) as per design report, connecting to hose reel cabinets located in Crop Market Block (2 cabinets) and Vegetable Market Block (2 cabinets). Include full hydrostatic pressure test (15 bar for 2 hours, no leakage), flow test (757 L/min at ≥100 psi at most remote outlet), and flushing. Provide mill certificates, valve test reports, hydrostatic test report, flow test report, and as-built drawings. SET 1.00 0.00
2.3 Fire Hose Reel Cabinet Assembly (Class II) – Supply, install, and commission one complete Class II hose reel assembly conforming to NFPA 14, including: stainless steel/steel cabinet (1.2 mm thickness) with transparent panel, 30 m rubber-lined hose (19 mm internal diameter, 15 bar pressure rating), shut-off nozzle (6 mm orifice, solid stream/spray pattern), 1.5-inch (38 mm) inlet connection, non-return valve, angle valve with quick-release coupling. Mount at 1.2 m height to center of operating handle. Include red reflective labeling in English and Arabic. № 4.00 0.00
2.4 Portable Fire Extinguisher (ABC Dry Chemical) – Supply and mount one portable fire extinguisher, ABC dry chemical type (monoammonium phosphate, minimum 90%), stored-pressure type with metal valve body, pressure gauge with green zone indicator, corrosion-resistant finish, rating as specified, wall mounting bracket, inspection tag, and operating instructions in English and Arabic. № 14.00 0.00
2.5 Ditto ( 2.4) but CO2 type for pump/ control/panel room № 2.00 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.4.1- Multi Purpose Hall Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 GLAZING USD 0.00
8 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 230.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 115.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 189.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 19.00 0.00
1.5 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 27.00 0.00
1.6 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 100.00 0.00
1.7 Ditto as above item 1.5 but around isolated footing. m3 167.00 0.00
1.8 Ditto as above item 1.5 but around masonry foundation wall. m3 10.00 0.00
1.9 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 394.00 0.00
1.1 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 153.00 0.00
1.11 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 108.00 0.00
1.12 Ditto as above item 1.10 but construction joint between grade slab & grade slab where the slab area is larger. ml 28.00 0.00
1.13 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 93.00 0.00
2.1.2 Under masonry foundation wall m2 36.00 0.00
2.1.3 Under grade beam m2 8.00 0.00
2.1.4 Under slab on grade including ramp. m2 153.00 0.00
2.1.5 Under masonry steps on grade m2 1.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 34.00 0.00
2.2.2 In foundation column. m3 2.60 0.00
2.2.3 In grade beams. m3 6.30 0.00
2.2.4 In 10 cm thick ground floor slab including ramps & outdoor tratment. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 153.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 59.00 0.00
2.3.2 To foundation column m2 35.00 0.00
2.3.3 To grade beams & ramps edge m2 49.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 8 mm deformed bar Kg 56.00 0.00
Dia 12 mm deformed bar Kg 1,246.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 145.00 0.00
Dia 16 mm deformed bar Kg 737.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 227.00 0.00
Dia 12 mm deformed bar Kg 407.00 0.00
Dia 16 mm deformed bar Kg 102.00 0.00
2.4.4 For floor slab on grade, ramp slab & outdoor tratment slab
Dia 8 mm deformed bar Kg 624.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 36.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 1.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 5.80 0.00
1.1.2 In top tie beams m3 5.40 0.00
1.1.3 In lintel beams including roof vent windows m3 0.80 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 77.00 0.00
1.2.2 To top tie beams m2 62.00 0.00
1.2.3 To lintel beams including for roof vent windows m2 14.00 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 253.00 0.00
Dia 16 mm deformed bar Kg 839.00 0.00
1.3.2 For top tie beam
Dia 8 mm deformed bar Kg 227.00 0.00
Dia 12 mm deformed bar Kg 407.00 0.00
Dia 16 mm deformed bar Kg 102.00 0.00
1.3.3 For water tanker slab & beam
Dia 6 mm deformed bar Kg 24.00 0.00
Dia 12 mm deformed bar Kg 90.00 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for plastering. m2 173.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 192.00 0.00
3.2 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet ridge cup at the roof slope direction changes. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of ridge cap: 80 cm. m.l. 21.00 0.00
3.3 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 41.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors and windows all as per the drawing. All doors & windows should have vertical metal grill 25x25x2mm c/c 15cm behind glazing for burglar proofing. Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint. (glazing measured separately).
D-1 size 200cm x 360cm no 1.00 0.00
D-2 size 100cm x 360cm no 2.00 0.00
W-1 size 140cm x 250cm no 12.00 0.00
4.2 Supply, fabricate and fix metal ramp handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 3.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect steel structures using RHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards. Price shall include gusset plat, connection plate when truss members connect and bolts other than anchor/J-bolt bolts.
A.1 RHS 80 x 80 x 4mm upper & lower truss member for T1 Kg 1,100.00 0.00
A.2 RHS 60 x 60 x 4mm diagonal & vertical truss member for T1 Kg 695.00 0.00
B. RHS Purlins 0.00
B.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 40 x 40 x 3mm L= 40mm angle iron. Price include angle iron. Kg 1,526.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate for verenda post-size 250 x 250 x 6mm with 4 dia 18 slotted holes. The plated is welded to the RHS post (fillet weld of 3mm throat thickness) and connected to the other plate fixed on concrete column. No 24.00 0.00
A.2 Gussate plate size 200 x 160 x 6mm. The plate is welded to the truss (fillet weld of 3mm throat thickness) No 12.00 0.00
A.3 Gussate plate size 300 x 160 x 6mm. The plate is welded to the truss (fillet weld of 3mm throat thickness) No 24.00 0.00
A.4 Metal plate 40x200x3 welded to truss and bolted to angle iron-2 ∅8mm bolt to connect angle iron to metal plate No 72.00 0.00
B Bolt with nut
B.1 Base plate/Anchor bolt dia. 16 Length 250mm for truss beam connection and to be weld to ring beam steel reinforcement No 48.00 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of fine cement sand finish to internal brick wall surfaces. m2 177.00 0.00
6.2 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of fine cement sand finish to internal exposed beam and column surfaces. m2 21.00 0.00
6.3 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive rendering finish to externall brick wall surfaces. m2 146.00 0.00
6.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final rendering finish to external exposed beam and column surfaces. m2 41.00 0.00
6.5 Prepare the surface and apply final a 3 mm to 5 mm thick final skim coat using a 1:3 cement-to-fine-sand mortar mix. Fine sand must be sieved through a 1.18 mm mesh. The surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks to internal wall, beam & column surfaces. m2 198.00 0.00
6.6 Prepare the surface and apply final apply 15mm thick cement and sand rendering (1:3 mix) for external wall surface. Price includes surface preparation, hacking of concrete surfaces, wire mesh for joints, curing for 7 days. The rendering pattern shall be as per the Architect approval. m2 187.00 0.00
6.7 Prepare the surface, supply and construct 2 cm thick x 25 cm wide polished marble threshold for doors bedded on cement sand mortar 1:3. Price include 30mm thick cement sand mortar backing and white cement grouting. All are as per the detail Ar. Dwg. ml 4.00 0.00
6.8 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 155.00 0.00
6.9 10cm high 1cm thick chamfered ceramic skirting of matching color to floor tiles. ml 74.00 0.00
6.10 Supply and fix granite stair tread bedded on cement mortar 1:3 price include mortar bed, nosing and chamfering. Color and pattern shall be approved by the Architect.
a) For entrance step-tread
- Tread size: (33 x 3 cm) ml 4.20 0.00
6.11 Ditto as above but riser.
a) For entrance step-rise
- riser size: (13.4 x 2 cm) ml 4.20 0.00
6.12 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick terrazzo window sill. Price shall include cement sand mortar bed and cement grouting. ml 17.00 0.00
6.13 Supply and fix chamfered, bullnose and water dripped 25 x 3cm thick terrazzo edge trim for veranda edge. Price shall include cement sand mortar bed and cement grouting. ml 12.00 0.00
6.14 Supply and fix approved quality 60 x 60cm gypsum board suspended ceiling as per the detail drawing and engineers approval. The fixing method shall be with T & L aluminum suspension syste. Price shall include gypsum, suspension systemcorner list, nails and all the necessary fixing accessories. m2 155.00 0.00
6.15 10 cm thick Concrete pavement around the building bedded on 10 cm thick red ash or fine aggregate and 20cm thick compacted granular materials. The work shall be mixing, placing, compacting, curing, and finishing of concrete with trowel finish while fresh. Price shall include red ash bed, selected fill and trowel finishing work. m2 58.00 0.00
Total Carried to summary USD 0.00
7.1 Supply and fix 0.5cm thick clear glass. Price shall include all the necessary fixing accessories. m2 42.00 0.00
7.2 Supply and fix 0.5cm thick figured glass. Price shall include all the necessary fixing accessories. m2 10.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
8.1 Apply three coats of plastic emulsion paint to internally plastered wall surfaces. m2 198.00 0.00
8.3 Ditto as item 8.1, but to chip wood ceiling. m2 155.00 0.00
8.3 Apply final acrylic emulsion point paint to external rendered wall surface, exposed R.C columns and beams. m2 187.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.4.2- Multi-Purpose Hall Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ELECTRICAL WORKS
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Flush-mounted sub distribution Board, SDB-MPH in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 25A,4P , Icu=10KA, coupled with RCD ,300mA, Type S/ Time delayed 0.00
3pc MCB of 20A, 2P, Icu=10KA
3pcs RCBO of 16A, 2P, Icu=6KA ,30mA 0.00
3pcs MCB of 10A, 2P, Icu=6KA
2pcs MCB of 16A, 2P (spare) Icu=10KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A, 3ph+N No 1.00 0.00
1.1.2 Flush-mounted sub distribution Board, SDB-UPS in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 20A, 2P, Icu=10KA ,coupled with RCD ,300mA, Type S/ Time delayed 0.00
3pcs RCBO of 16A, 2P, Icu=6KA, 30mA
2pcs MCB of 16A, 2P (spare) Icu=10KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A/1P+N. No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including unction boxes with covers insulating screw cap connectors complete. No 34.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L1 LED Panel Light: 600x600mm, 22.5W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 24.00 0.00
1.3.L2 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 4.00 0.00
1.3.(E) Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). IP65,IK08, 5700K, minimum 7W, autonomy 90min. Warranty: 3 years (components), 5 years (battery). No 5.00 0.00
1.3.(EX) Saftey only emergency with FLC 11SE or approved equivallent illuminated signage system shall be installed to give information with standard dimensions information displays and illumination level with double or single faces. The display consisting of symbols, text or figures supported with direction which will indicate EXIT, toilets (lady and gentlemen), staircases and floor level will be placed as indicated on the drawings throughout building for the convenience of the public and workers .The symbols, text or figures shall be choices of the client or engineer and shall be appropriate enough to describe the room, areas, services and all safety directions it should have emergency battery for at least 90min. No 1.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Double pole Switch No 4.00 0.00
1.4.2 Double pole Switch water proof for out door installation IP44. No 1.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 19.00 0.00
1.6 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.6.1 16A ,1ph ,230V 2p+e socket out let No 4.00 0.00
1.6.2 16A ,1ph,230V 2p+e socket out let water proof IP44. No 2.00 0.00
1.6.3 Dito but Double (Twin) Outlet No 6.00 0.00
1.6.4 Dito but Double (Twin) in Red for UPS Outlet No 7.00 0.00
Supply, install, test, and commission a 3.5 kVA, 230 V, single-phase online double-conversion UPS, complete with a minimum of 10 minutes of battery autonomy at full load, automatic static bypass, maintenance bypass, a sealed maintenance-free battery bank, intelligent battery charger, LCD display, pure sine wave output, power factor ≥ 0.9, and 95% efficiency in online mode. Communication interface, and all necessary protection, control, interconnecting cables, earthing, accessories, and mounting hardware. The UPS shall comply with IEC 62040-1, IEC 62040-2, and IEC 62040-3, and shall be complete with all materials and accessories required for a fully functional installation. No 1.00 0.00
1.8 DATA\ Telecome System 0.00
Tel/Data according to manufacturer’s and utility supplier’s requirements, supplied, installed, connected color coded including tags and tested, complete, all as specified and / or as shown on the drawings 0.00
Structured Cabling
Horizontal CAT6A Cabling
1.8.1 Tel/Data and Data/Data points fed through 2x(twisted pair category 6A UTP cable) inside FRLS PVC conduits of 20mm diameter and thickness not less than 1.5mm with conduits accessories (coupling, junction boxes) for tele/Data outlet socket. No 8.00 0.00
1.8.2 Cat 6A 24 port Patch Panel RJ 45 contact No 1.00 0.00
1.8.3 Cat 6A RJ 45 Patch Cord 0.5m, from switch to patch panels No 16.00 0.00
1.8.4 Cat 6A RJ 45 Patch Cord 3m, from outlets to workstation computers. No 8.00 0.00
Equipment Racking 0.00
1.8.5 Wall Mount metallic rack of 9U pivoting cabinet swing 19" steel enclosure with transparent and lockable door, Built-in PDUs (8-10 Outlets, Grounded) and cooling fans. No 1.00 0.00
1.8.6 1U Horizontal Cable Management Bars, 5 Vertical Plastic Hoops with Cover No 2.00 0.00
Information Outlets: Data &Voice 0.00
Extra Over Data Socket Outlets with Detachable Frames & Corresponding Box 0.00
1.8.7 2 x RJ45 8 Contact CAT6a Socket Outlets No 6.00 0.00
Active components Type CISCO or approved equivalent. 0.00
1.8.8 24-port Gigabit Data +2x10G uplink Switch . No 1.00 0.00
1.8.9 24 port voice patch panel for telephone connection No 1.00 0.00
1.8.10 Hybrid PBX with 24 Analog, with 4 trunk, Extension including Operator Phone No 1.00 0.00
1.8.11 Cat 6A RJ 11 Patch Cord 1m No 8.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.4.3- Multi-Purpose Hall Building-Sanitary
1 SANITARY EQUIPMENT & WATE PIPES USD 0.00
1 ROOF RAIN WATER DOWN PIPING SYSTEM USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.0 SANITARY EQUIPMENET ( FIXTURES )
All fixtures which are specified below is subject to the owner's / consultant's approval, based on samples, catalogues and brochures presented by the contractor. Unit price shall include all the necessary fixing brackets or hooks and all assistance civil works such as chiseling of walls, floors, beams and etc.
1.1 HAND WASH BASIN (ORDINARY)
Supply and fix R.A.K. or Equivalent, hand wash basins for first aid room made of white glazed vitreious china with REMER/JAQUAR or Equivalent chrome plated cold water tap, pedastal stand ,complete with stop & arrest valves on water inlet pipe. Chrome plated chain holder, P-smell trap with connection pipe, fittings, all other necessary etc.complete in all respects. Flexible hose to be REMER or Equivalent and should be capable of resisting pressure of 4 bar. P-smell trap should be brass chrome plated with 50mm height of water seal and trap. The unit price shall include 500ml automatic soap dispenser,crystal glass mirror of 500 x 400mm.
a) Size :- length X width (1000mm x 435mm) set 1.00 0.00
1.2 Supply, fix, test and commission floor drains made of polished steel, complete with P-smell trap /minimum seal depth 75mm/ and all other necessary fittings and accessories. No 1.00 0.00
1.3 Waste & vent Pipes and Accessories
All domestic waste pipe lines shall be uPVC (PN4) pipes and shall be provided with a minimum slope of 2% towards the outlet. All uPVC pipes and necessary fittings shall be standard quality and be free from damage during storage, construction and etc. Unit price shall include all the necessary assistance civil works, such as excavation cartaway, fixing or hanging to walls, beams or slabs.etc., necessary fittings such as bends, Y, T, FCO(Floor clean out) etc.
Dia. 50 mm ml 6.00 0.00
Total carried to summary USD 0.00
1.0 ROOF RAIN WATER DOWNPIPING SYSTEM
3.2 Rainwater Downpipe DN 100 (Office + Multipurpose Hall) – Supply, install, test, and commission one uPVC rainwater downpipe, DN 100 mm nominal diameter, conforming to ISO 1452-1 or AS/NZS 1260, minimum wall thickness 2.5 mm. Include stainless steel leaf guard (5 mm mesh) at roof inlet, galvanized pipe brackets (vertical spacing 1.8 m maximum, horizontal spacing 1.0 m maximum), UV-reflective light-colored oil paint coating (white/light grey) conforming to ISO 4892-2 on all exposed sections, and discharge splash block at base. Complete from roof outlet to ditch/splash block. ml 20.00 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.5.1- Security/Guard House Building-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 GLAZING USD 0.00
8 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 50.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 25.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 18.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 2.00 0.00
1.5 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 7.00 0.00
1.6 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 21.00 0.00
1.7 Ditto as above item 1.5 but around isolated footing. m3 17.00 0.00
1.8 Ditto as above item 1.5 but around masonry foundation wall. m3 4.00 0.00
1.9 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 61.00 0.00
1.1 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 19.00 0.00
1.11 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 15.00 0.00
1.12 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 7.00 0.00
2.1.2 Under masonry foundation wall m2 13.00 0.00
2.1.3 Under slab on grade including ramp. m2 19.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.2.1 In isolated footing. m3 1.75 0.00
2.2.2 In foundation column. m3 0.50 0.00
2.2.3 In grade beams. m3 1.20 0.00
2.2.4 In 10 cm thick ground floor slab including ramps & outdoor tratment. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 19.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.3.1 To isolated footing. m2 6.00 0.00
2.3.2 To foundation column m2 8.00 0.00
2.3.3 To grade beams & ramps edge m2 10.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.4.1 For footing pad
Dia 12 mm deformed bar Kg 85.00 0.00
2.4.2 For Foundation column
Dia 8 mm deformed bar Kg 29.00 0.00
Dia 16 mm deformed bar Kg 92.00 0.00
2.4.3 For grade beam
Dia 8 mm deformed bar Kg 47.00 0.00
Dia 12 mm deformed bar Kg 98.00 0.00
2.4.4 For floor slab on grade & ramp slab
Dia 8 mm deformed bar Kg 77.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 13.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 1.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 0.75 0.00
1.1.2 In top tie beams m3 1.20 0.00
1.1.3 In lintel beams including roof vent windows m3 0.20 0.00
1.1.4 In lnternal partition tie beam m3 0.20 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 12.00 0.00
1.2.2 To top tie beams m2 14.00 0.00
1.2.3 To lintel beams including for roof vent windows m2 3.00 0.00
1.2.4 To internal partition tie beam m2 2.00 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 38.00 0.00
Dia 16 mm deformed bar Kg 199.00 0.00
1.3.2 For top tie beam
Dia 8 mm deformed bar Kg 47.00 0.00
Dia 12 mm deformed bar Kg 98.00 0.00
1.3.3 For lintel beam
Dia 6 mm deformed bar Kg 4.00 0.00
Dia 12 mm deformed bar Kg 15.00 0.00
1.3.4 For internal partition tie beam
Dia 8 mm deformed bar Kg 9.22 0.00
Dia 12 mm deformed bar Kg 19.54 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for plastering. m2 44.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 18.00 0.00
3.2 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 12.00 0.00
3.3 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 5.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors and windows all as per the drawing. All doors & windows should have vertical metal grill 25x25x2mm c/c 15cm behind glazing for burglar proofing. Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint. (glazing measured separately).
D-1 size 90cm x 210cm no 2.00 0.00
W-1 size 140cm x 120cm no 2.00 0.00
4.2 Supply, fabricate and fix metal ramp handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 5.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect steel structures using RHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel rafter
Steel rafters and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards. Price shall include gusset plat, connection plate when truss members connect and bolts other than anchor/J-bolt bolts.
A.1 RHS 100 x 60 x 3mm rafter Kg 63.00 0.00
B. RHS Purlins 0.00
B.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 40 x 40 x 3mm L= 40mm angle iron. Price include angle iron. Kg 129.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate for verenda post-size 250 x 150 x 6mm with 4 dia 18 slotted holes. The plated is welded to the RHS post (fillet weld of 3mm throat thickness) and connected to the other plate fixed on concrete column. No 8.00 0.00
A.2 Angle late size 150 x 150 x 6mm. The plate is welded to the rafter (fillet weld of 3mm throat thickness) No 8.00 0.00
A.3 Gussate plate size 40 x 200 x 3mm. The plate is welded to the truss (fillet weld of 3mm throat thickness) and bolted with 2 dia. 8mm bolt. Price include bolt No 12.00 0.00
B Bolt with nut
B.1 Base plate/Anchor bolt dia. 16 Length 250mm for truss beam connection and to be weld to ring beam steel reinforcement No 12.00 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final/third coat of fine cement sand finish to internal brick wall surfaces. m2 49.00 0.00
6.2 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of fine cement sand finish to internal exposed beam and column surfaces. m2 3.00 0.00
6.3 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive rendering finish to externall brick wall surfaces. m2 45.00 0.00
6.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final rendering finish to external exposed beam and column surfaces. m2 12.00 0.00
6.5 Prepare the surface and apply final a 3 mm to 5 mm thick final skim coat using a 1:3 cement-to-fine-sand mortar mix. Fine sand must be sieved through a 1.18 mm mesh. The surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks to internal wall, beam & column surfaces. m2 52.00 0.00
6.6 Prepare the surface and apply final apply 15mm thick cement and sand rendering (1:3 mix) for external wall surface. Price includes surface preparation, hacking of concrete surfaces, wire mesh for joints, curing for 7 days. The rendering pattern shall be as per the Architect approval. m2 57.00 0.00
6.7 Prepare the surface, supply and construct 2 cm thick x 25 cm wide polished marble threshold for doors bedded on cement sand mortar 1:3. Price include 30mm thick cement sand mortar backing and white cement grouting. All are as per the detail Ar. Dwg. ml 1.00 0.00
6.8 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 13.00 0.00
6.9 10cm high 1cm thick chamfered ceramic skirting of matching color to floor tiles. ml 19.00 0.00
6.1 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick terrazzo window sill. Price shall include cement sand mortar bed and cement grouting. ml 3.00 0.00
6.11 Supply and fix approved quality 60 x 60cm gypsum board suspended ceiling as per the detail drawing and engineers approval. The fixing method shall be with T & L aluminum suspension syste. Price shall include gypsum, suspension systemcorner list, nails and all the necessary fixing accessories. m2 13.00 0.00
6.12 10 cm thick Concrete pavement around the building bedded on 10 cm thick red ash or fine aggregate and 20cm thick compacted granular materials. The work shall be mixing, placing, compacting, curing, and finishing of concrete with trowel finish while fresh. Price shall include red ash bed, selected fill and trowel finishing work. m2 9.00 0.00
Total Carried to summary USD 0.00
7.1 Supply and fix 0.5cm thick clear glass. Price shall include all the necessary fixing accessories. m2 3.36 0.00
7.2 Supply and fix 0.5cm thick figured glass. Price shall include all the necessary fixing accessories. m2 1.08 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
8.1 Apply three coats of plastic emulsion paint to internally gypsum plastered wall surfaces. m2 52.00 0.00
8.3 Ditto as item 8.1, but to chip wood ceiling. m2 13.00 0.00
8.3 Apply final acrylic emulsion point paint to external rendered wall surface, exposed R.C columns and beams. m2 57.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.5.2- Security/Guard House Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ELECTRICAL WORKS
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Flush-mounted sub distribution Board, SDB-SR1 in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 20A, 2P , Icu=10KA, coupled with RCD ,300mA, Type S/ Time delayed 0.00
1pcs RCBO of 16A, 2P, Icu=6KA ,30mA 0.00
1pcs MCB of 10A, 2P, Icu=6KA
1pcs MCB of 16A, 2P (spare) Icu=10KA 0.00
1Pc of surge arrestor of 20KA, Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A/1P+N. No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 6.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L1 LED Panel Light: 600x600mm, 22.5W, 3600 lumens, 4000K, CRI > 80, recessed ceiling-mounted, aluminum frame with opal diffuser, IP20, UGR < 19, flicker-free. No 1.00 0.00
1.3.L2 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 3.00 0.00
1.3.L3 Circular LED Ceiling Light D230, 13W, 400K,1300Lumen CRI > 80, ceiling-mounted, aluminum with acrylic diffuser, IP44, flicker-free. No 2.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Single Pole 1-Way Switch No 2.00 0.00
1.4.2 Single Pole 1-Way Switch, weather-proof IP54 No 1.00 0.00
1.4.3 Two Way Switch No 2.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 5.00 0.00
1.5 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.5.1 16A ,1ph ,230V 2p+e socket out let No 4.00 0.00
1.5.2 Dito but Double (Twin) Outlet No 1.00 0.00
1.6 DATA\ Telecome System 0.00
Tel/Data according to manufacturer’s and utility supplier’s requirements, supplied, installed, connected color coded including tags and tested, complete, all as specified and / or as shown on the drawings 0.00
1.6.1 2 x RJ45 8 Contact CAT6a Socket Outlets No 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.5.3- Security/Guard House Building-Sanitary
1 ROOF RAIN WATER DOWNPIPING SYSTEM USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 ROOF RAIN WATER DOWN PIPING SYSTEM
1.1 Rainwater Downpipe DN 80 (Guard House) – Supply, install, test, and commission one uPVC rainwater downpipe, DN 80 mm nominal diameter, conforming to ISO 1452-1 or AS/NZS 1260, minimum wall thickness 2.0 mm. Include stainless steel leaf guard (5 mm mesh) at roof inlet, galvanized pipe brackets (vertical spacing 1.8 m maximum, horizontal spacing 1.0 m maximum), UV-reflective light-colored oil paint coating (white/light grey) conforming to ISO 4892-2 on all exposed sections, and discharge splash block at base. Complete from roof outlet to ditch/splash block. ml 20.00 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.6.1- Toilet -Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A USD 0.00
B. SUPER-STRUCTURE
1 CONCRETE WORK USD 0.00
2 BLOCK WORK USD 0.00
3 ROOFING USD 0.00
4 METAL WORK USD 0.00
5 STEEL STRUCTURE USD 0.00
6 FINISHING USD 0.00
7 PAINTING USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
E) The Contractor is advised to review the Soil Investigation Report or conduct their own soil investigation. The Contractor shall ensure full awareness of the soil classification indicated in the Geotechnical Report before finalizing the unit rates for any excavation or connection works.
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net built up area including aprons, open ditch and ramp. m2 156.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes aprons, open ditch and ramp. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 78.00 0.00
1.3 Pit excavation for isolated footing in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 25 cm working space in each side for pit excavation. m3 36.00 0.00
1.4 Ditto as above item 1.3 but from 150cm to 300cm m3 4.00 0.00
1.5 Pit excavation for pit latrin in ordinary soil to a depth not exceeding 150 cm from reduced ground level (inverted bulk excavation level). Note: measurement shall include 100 cm working space in each side for pit excavation. m3 80.00 0.00
1.5 Ditto as above item 1.5 but from 150cm to 300cm m3 32.00 0.00
1.6 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level (inverted bulk excavation level). Note: measurement shall include 15 cm working space in each side for trench excavation. m3 11.00 0.00
1.7 Selected borrow fill under hard core with satisfactory soil (Selected Material) conforming to ASTM D 2487 soil classification groups GW, GP, GM, SW, SP, and SM, or a combination of these group symbols; free of rock or gravel larger than 3 inches (75 mm) in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter and a swell potential of less than 3%.. The compaction achieved in filling shall be measured in accordance with the standard practice. The In situ moisture content and density shall be compared with laboratory test results of modified AASHO T147 performed on samples of the selected material. The final levels of fill shall be adjusted, graded and prepared to receive bedding to be laid on fill. All are as per the structural drawing general note. m3 69.00 0.00
1.8 Ditto as above item 1.7 but around isolated footing. m3 35.00 0.00
1.9 Ditto as above item 1.7 but around pit laterin shear wall m3 79.00 0.00
1.10 Ditto as above item 1.7 but around masonry foundation wall. m3 7.00 0.00
1.11 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material by persons that are subcontracted by the contractor. Disposal shall be measured as the net volume arising from the void created by the excavation. m3 270.00 0.00
1.1 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone. m2 57.00 0.00
1.11 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 68.00 0.00
1.12 Allow lump sum amount of dewatering from excavation pit. ls 1.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
2.1 5 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :
2.1.1 Under isolated footing m2 16.00 0.00
2.1.2 Under masonry foundation wall m2 23.00 0.00
2.1.3 Under grade beam m2 3.00 0.00
2.1.4 Under slab on grade including ramp. m2 57.00 0.00
2.2 10 cm thick lean concrete in grade/class C-5 concrete , minimum cement content of 150 kg/m3 :under pit latterin bottom slab. 29.00 0.00
2.3 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
2.3.1 In isolated footing. m3 4.05 0.00
2.3.2 In foundation column. m3 0.80 0.00
2.3.3 In grade beams. m3 4.60 0.00
2.3.4 In 10 cm thick ground floor slab including ramps & outdoor tratment. Where internal partition walls bear on the slab, increase slab thickness by additional 10 cm as shown in the st. drawing m2 57.00 0.00
2.3.5 In 15cm thick ramp slab. m2 3.00 0.00
2.3.6 In pit laterin bottom slab, shear wall & top slab m3 25.00 0.00
2.4 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
2.4.1 To isolated footing. m2 11.00 0.00
2.4.2 To foundation column m2 12.00 0.00
2.4.3 To grade beams & ramps edge m2 30.00 0.00
2.4.4 To pit latrin slab & shear wall m2 120.00 0.00
2.5 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
2.5.1 For footing pad
Dia 8 mm deformed bar Kg 13.00 0.00
Dia 12 mm deformed bar Kg 192.00 0.00
2.5.2 For Foundation column
Dia 8 mm deformed bar Kg 97.00 0.00
Dia 16 mm deformed bar Kg 343.00 0.00
2.5.3 For grade beam
Dia 8 mm deformed bar Kg 207.00 0.00
Dia 12 mm deformed bar Kg 404.00 0.00
2.5.4 For floor slab on grade, ramp slab
Dia 8 mm deformed bar Kg 247.00 0.00
Dia 10 mm deformed bar Kg 12.00 0.00
2.5.5 For fpit laterin
Dia 12 mm deformed bar Kg 3,170.00 0.00
Total carried to summary USD 0.00
3.1 45 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 23.00 0.00
3.2 Ditto as item 3.1, but, above NGL and steps m3 1.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
1 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately unless otherwise described.
1.1 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. Formwork and reinforcement bars are measured separately.
1.1.1 In elevation columns from ground to roof m3 2.40 0.00
1.1.2 In top tie beams m3 3.65 0.00
1.1.3 In internal partition tie beams m3 1.32 0.00
1.2 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
1.2.1 To elevation columns from ground to roof m2 28.00 0.00
1.2.2 To top tie beams m2 42.00 0.00
1.2.2 To internal partition tie beams m2 13.20 0.00
1.3 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc. and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
1.3.1 For elevation column from ground to roof
Dia 8 mm deformed bar Kg 154.00 0.00
Dia 16 mm deformed bar Kg 249.00 0.00
1.3.2 For top tie beam
Dia 8 mm deformed bar Kg 139.00 0.00
Dia 12 mm deformed bar Kg 278.00 0.00
1.3.3 For internal partition tie beam
Dia 8 mm deformed bar Kg 60.83 0.00
Dia 12 mm deformed bar Kg 117.22 0.00
Total carried to summary USD 0.00
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
2.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for plastering. m2 131.00 0.00
Total carried to summary USD 0.00
3.1 Supply and fix approved standard pre-painted 0.5mm thick EGA-500 (high tensile galvanized steel sheet with minimum G90 zinc coating, roll formed to profile having 5-rib trapezoidal drainage profile within effective cover width and rib height as per manufacturer’s standard specification or specified below) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). The standard cross section profile shall be overall width: 830 mm (total physical width of the metal sheet), effective cover Width: 760 mm (the actual area covered after deducting the side overlap), Pitch (Distance between ribs): 207.5mcm center-to-center & Rib Crest Height: ~25 mm to 27 mm (provides the rigid water channel depth) m2 75.00 0.00
3.2 Supply and fix pre-painted, weather-resistant, 0.5 mm thick galvanized steel sheet flashing at the top roof ridge HCB wall & rood connection. The rate shall include all necessary accessories such as corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of appron flashing 250mm & over flashing 130mm. m.l. 23.00 0.00
3.3 Supply and fix pre-painted, weather-resistant 0.5 mm thick galvanized steel gutter at the lower roof level, supported on 20 × 6 mm metallic brackets at 2,000 mm spacing. The rate shall include 40 x 25 x 3mm RHS support/hanger fixed at the truss lower tip along the gutter, all necessary accessories including corner closures, rubber weather seals, and related fittings. All details and installation shall strictly follow the Architectural drawings. Developed length of gutter: 1,065 mm ml 16.00 0.00
Total carried to summary USD 0.00
4.1 Supply and fix 38mm thick LTZ frame doors and windows all as per the drawing. All doors infill/covered with 0.5mm thick flat metal sheet pannel & windows should have infil with vertical metal grill 25x25x2mm c/c 15cm . Price shall include Orlando or equivalent locks and hinges,one coat of primer and two coats of synthetic enamel paint.
D-1 size 100cm x 200cm no 2.00 0.00
D-2 size 80cm x 200cm no 10.00 0.00
W-1 size 60cm x 40cm no 12.00 0.00
4.2 Supply, fabricate and fix metal ramp handrail made of galvanized steel plate base and CHS tubular handrail assembly as follows: base plate 100 × 100 × 8 mm fixed to concrete with 4 no. Ø12 anchor bolts; main vertical posts: fixed every 1000mm spaced CHS Ø40 × 2.5 mm, height 900 mm above finished floor level; top handrail CHS Ø50 × 2.5 mm welded on the vertical main post and continuously; top rail & ramp floor rails. Fabrication, welding, installation, fixing and finishes as per drawing and specification. Price includes supply of all plates, anchor bolts, filler, welds, shims, hole cutting/drilling, edge grinding, one coat anti-rust primer and two coats metal paint, transport to site, temporary protection and all labor, tools and scaffolding necessary to complete the work. ml 11.00 0.00
Total carried to summary USD 0.00
5 STEEL STRUCTURE
5.1 Supply, fabricate, assemble, and erect steel structures using RHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel rafter
Steel rafters and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards. Price shall include gusset plat, connection plate when truss members connect and bolts other than anchor/J-bolt bolts.
A.1 RHS 100 x 60 x 3mm rafter Kg 201.00 0.00
B. RHS Purlins 0.00
B.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 40 x 40 x 3mm L= 40mm angle iron. Price include angle iron. Kg 519.00 0.00
5.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate for verenda post-size 250 x 150 x 6mm with 4 dia 18 slotted holes. The plated is welded to the RHS post (fillet weld of 3mm throat thickness) and connected to the other plate fixed on concrete column. No 12.00 0.00
A.2 Angle late size 150 x 150 x 6mm. The plate is welded to the rafter (fillet weld of 3mm throat thickness) No 12.00 0.00
A.3 Gussate plate size 40 x 200 x 3mm. The plate is welded to the truss (fillet weld of 3mm throat thickness) and bolted with 2 dia. 8mm bolt. Price include bolt No 36.00 0.00
B Bolt with nut
B.1 Base plate/Anchor bolt dia. 16 Length 250mm for truss beam connection and to be weld to ring beam steel reinforcement No 24.00 0.00
Total carried to summary USD 0.00
Finishing work includes all surface pre cleaning, removal of mortar by chiseling, making good edges of columns and beams, preparation of grooves b/n surface where ever indicated, preparation and application of finish, polishing and cleaning after end of work.
6.1 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final/third coat of fine cement sand finish to internal brick wall surfaces. m2 140.00 0.00
6.2 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final coat of fine cement sand finish to internal exposed beam and column surfaces. m2 18.00 0.00
6.3 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive rendering finish to externall brick wall surfaces. m2 104.00 0.00
6.4 Prepare the surface and apply two coats of cement sand plaster (1:3) to receive final rendering finish to external exposed beam and column surfaces. m2 33.00 0.00
6.5 Prepare the surface and apply final a 3 mm to 5 mm thick final skim coat using a 1:3 cement-to-fine-sand mortar mix. Fine sand must be sieved through a 1.18 mm mesh. The surface must be continuously finished with a steel trowel to achieve a perfectly smooth, hard, and dense finish free of trowel marks to internal wall, beam & column surfaces. m2 158.00 0.00
6.6 Prepare the surface and apply final apply 15mm thick cement and sand rendering (1:3 mix) for external wall surface. Price includes surface preparation, hacking of concrete surfaces, wire mesh for joints, curing for 7 days. The rendering pattern shall be as per the Architect approval. m2 137.00 0.00
6.7 Prepare the surface, supply and construct 2 cm thick x 25 cm wide polished marble threshold for doors bedded on cement sand mortar 1:3. Price include 30mm thick cement sand mortar backing and white cement grouting. All are as per the detail Ar. Dwg. ml 14.00 0.00
6.8 Prepare the surface, supply and fix nominal thickness of 8.5mm approved standard 40 x 40 cm non-slippery ceramic floor tiles bedded in an average 41.5mm thick cement sand mortar mix (1:3) price includes cement sand mortar. Color and pattern shall be approved by the architect. m2 59.00 0.00
6.13 Supply and fix 30 x 60 x 0.85 cm ceramic wall cladding, of matching color to floor, stuck to wall with cement sand mortar 1:3 backing and grouting with white cement wash. Price shall include rod anchors to backing. Size, color and pattern according to architect's drawings. m2 168.00 0.00
6.12 Supply and fix chamfered, bullnose and water dripped 28 x 3cm thick terrazzo window sill. Price shall include cement sand mortar bed and cement grouting. ml 8.00 0.00
6.15 10 cm thick Concrete pavement around the building bedded on 10 cm thick red ash or fine aggregate and 20cm thick compacted granular materials. The work shall be mixing, placing, compacting, curing, and finishing of concrete with trowel finish while fresh. Price shall include red ash bed, selected fill and trowel finishing work. m2 12.00 0.00
Total Carried to summary USD 0.00
Paint surfaces shall be clean by removing grease, dust or cleaning the surfaces. Removing, undercoats shall be applied evenly over the whole surface to give a solid film, care being taken to avoid uneven thickness of paint at edge and angles. Finishing coats shall be applied evenly over the whole surface to give a solid film free from brush marks, sags, runs, orange peeling or other defects. All repairs shall be primed before undercoating is applied. Dubbing out shall be made in the same material as plaster. Dubbing out to make up uneven surfaces of walls, floors etc. shall be made before the application of the undercoat. Finally clean all areas affected by painting, by washing, paint removal of affected areas and polishing surface to ensure that no paint marks are left on the affected areas.
7.1 Apply three coats of plastic emulsion paint to internally gypsum plastered wall surfaces. m2 158.00 0.00
7.3 Apply final acrylic emulsion point paint to external rendered wall surface, exposed R.C columns and beams. m2 137.00 0.00
Total Carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.6.2- Toilet Building-Electrical
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Flush-mounted sub distribution Board, SDB-TO-1 in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories,and consisting: 0.00
1pc main MCB of 16A, 2P , Icu=10KA, coupled with RCD ,300mA, Type S/ Time delayed 0.00
2pcs MCB of 10A, 2P, Icu=6KA
1pcs MCB of 10A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A/1P+N. No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 24.00 0.00
1.3 Light Fittings and Lamps 0.00 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W,4000K, 3600Lumen, CRI > 80, ceiling-mounted, polycarbonate, flicker-free, IP66, for outdoor instalation No 10.00 0.00
1.3.L3 Circular LED Ceiling Light D230, 13W, 400K,1300Lumen CRI > 80, ceiling-mounted, aluminum with acrylic diffuser, IP44, flicker-free. No 12.00 0.00
1.3.(E) Non-maintained LED emergency light (only activates during power failure). Compliance: Meets UL 924, NFPA 101, EN 1838, and/or BS 5266 standards for emergency lighting. Self-test (30s monthly, 60min annual per IEC 62034). Lifespan: 50,000–100,000 hours (LED). IP65,IK08, 5700K, minimum 7W, autonomy 90min. Warranty: 3 years (components), 5 years (battery). No 2.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Single Pole 1-Way Switch No 2.00 0.00
1.4.2 Double pole Switch No 3.00 0.00
1.4.3 Double pole Switch Weather proof for outdoor installation, IP54 No 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.6.3- Toilet Building-Sanitary
1 WATER SUPPLY SYSTEMS USD 0.00
2 WASTE WATER DRAINAGE SYSTEMS USD 0.00
3 ROOF RAIN WATER DOWNPIPING SYSTEM USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 WATER SUPPLY SYSTEMS
1.1 Water Supply Piping Systems
1.1.1 Polypropylene Random Copolymer (PPR) pipe system for gravity-fed water supply from EWT to faucet, PN10, complete with all necessary fittings,elbow,stop valve,coupler,adapter,wall brackets, joints, and accessories for a fully functional system. Pipe and fittings shall comply with ISO 15874 / DIN 8077/8078. The unit price shall include Low-pressure wall-mounted faucet, complete with: swivel spout, aerator, lever-operated handle, wall mounting plate, fixing screws, and all necessary accessories. Faucet shall be certified for operation at minimum 0.1 bar residual pressure.
PPR pipe, DN20, PN10, SDR 11 lm 6.00 0.00
1.1.2 Supply, deliver, mount, test, and commission a hot press molded sectional Glass Reinforced Plastic (GRP) water tank system with total effective capacity of 36,000 liters (36 m³), comprising fire reserve compartment (27,000 liters / 27 m³) and domestic/non-potable water compartment (9,000 liters / 9 m³) separated by a watertight GRP partition, with individual connections and isolation valves for each compartment to allow independent operation and maintenance. Tank to be manufactured from food-grade GRP material conforming to ISO 14692, complying with NFPA 22 (fire reserve) and WRAS/NSF 61 (domestic water), with external hot-dip galvanized steel bracing (ISO 1461) and UV-resistant coating (ISO 4892-2). Designed for atmospheric working pressure with minimum 300 mm freeboard and shall withstand hydrostatic test pressure of 1.5 times the design head. Tank to be installed at ground level on a reinforced concrete slab (minimum 500 mm thick) raised 500 mm above NGL for flood protection, with steel rebar reinforcement (12 mm diameter @ 200 mm centers) extending minimum 300 mm beyond the tank footprint, and 150 mm high flood curb around slab perimeter. Complete with lockable manhole cover (minimum 600 mm diameter) with insect-proof vent, screened vent with 12 mm mesh, internal GRP ladder, external aluminum ladder with anti-slip platform and guardrails (ISO 14122), mechanical "Cat and Mouse" water level indicator or ultrasonic level sensor (one per compartment), sampling tap for water quality testing, earth bonding connection, fall protection anchor point, and the following connections: DN50 PN16 inlet with bronze gate valve and float valve, DN50 PN16 domestic outlet with bronze gate valve and expansion joint, DN80 PN16 fire outlet with bronze gate valve and expansion joint, DN50 drain with bronze gate valve and scour outlet, and DN65 overflow with 12 mm insect-proof mesh screened and directed away from the tank. All piping and fittings to be uPVC or stainless steel with stainless steel bolts and EPDM/food-grade gaskets. Installation to include on-site assembly, watertight sealing, hydrostatic testing per compartment (24 hours, no leakage), disinfection and first-fill procedure, drainage channel around slab, and labeling "POTABLE WATER – FIRE & DOMESTIC SUPPLY" in English and Arabic. Provide manufacturer’s certificates, test reports, and O&M manuals. № 1.00 0.00
1.1.3 Ditto Item 1.1.2 but with total effective capacity of 8,000 liters (8 m³) serving non-potable toilet wash purposes (hand washing), with DN50 PN16 inlet, DN50 PN16 outlet, DN50 drain, and DN65 overflow connections, installed on a reinforced concrete slab raised 500 mm above NGL for flood protection, and labeled "NON-POTABLE WATER – TOILET WASH" in English and Arabic. set 1.00 0.00
1.1.4 Elevated Water Tank (250 Liters) – Supply, install, and commission one food-grade polyethylene elevated water tank, nominal capacity 250 liters, conforming to ISO 4422. Include structural support as shown in the detail structural drawing, float valve or level sensor (adjustable high/low setpoints), overflow pipe (DN 25) with screen,chlorination pipe DN32, drain plug, lockable lid, outlet strainer (1 mm mesh), and DN 25 /DN32 gate valve for isolation. Mounting height: 2.5 m above NGL. № 2.00 0.00
1.1.5 Supply, install, test, and commission a complete centrifugal pump set (twin) for water transfer duty from GRP tank to elevated water tanks (EWTs), fully functional system including all auxiliary components: centrifugal pump complete with electric motor (0.25 kW, 0.33 HP, 380/400V, 3-phase, 50 Hz), base frame, coupling guard, anti-vibration mountings, suction and discharge flanges, pressure gauge, priming plug, drain plug, and all necessary fittings. Pump suitable for pumping potable water at 60 L/min flow rate and 4.27 m total dynamic head (worst-case condition: Tank 1 isolated, full flow to Tank 2) as calculated in the hydraulic design. Provide Variable Frequency Drive (VFD) panel complete with inverter drive, PLC controller with PID control logic, digital display, manual/auto selector switch, emergency stop button, phase monitoring relay, overload protection, short circuit protection, and all necessary control wiring, VFD rated for 0.25 kW motor and IP54 enclosure. Provide ultrasonic level sensors for both elevated water tanks complete with 4-20 mA output, IP67 enclosure, mounting bracket, cable gland, and all necessary accessories (range: 0-1.0 m) with "Highest Level Dominant" control logic per API 2350. Provide pump suction pipe assembly with strainer complete with foot valve, suction strainer, flexible coupling, isolation valve, and all necessary fittings. Provide pump discharge pipe assembly complete with non-return valve (check valve), gate valve, pressure relief valve, pressure gauge with siphon and isolation cock, flexible coupling, and all necessary fittings. Provide pressure switch for pump control and protection complete with adjustable set points, NEMA 4 enclosure, and all necessary accessories. Provide control panel enclosure IP54 rated complete with main isolator switch, contactors, overload relays, fuses, indicator lamps, push buttons, terminal blocks, wiring duct, and all necessary internal wiring. Provide cable and wiring from control panel to pump, VFD, level sensors (for both EWTs), and power supply complete with armored cables, control cables, cable trays, conduits, glands, lugs, and all necessary accessories. Reference pump brand: PEDROLLO CP 100 or equivalent approved brand. № 2.00 0.00
1.1.6 High-Density Polyethylene (HDPE) pipe, PN10, SDR 17, black with blue stripes, complete with all necessary fittings, elbow, T connections,joints, and accessories for a fully functional water supply system. Pipe material shall comply with ISO 4427 / BS EN 12201. The unit price shall also consider Isolation/balancing gate valves, DN40/DN32/dn25, flanged ends, PN16, ductile iron body, complete with handwheel, gland packing, and all necessary accessories, air release valve, pressure release valve, washout connection at DN40 pipe.
HDPE pipe DN40 PN10 lm 50.00 0.00
HDPE pipe DN32 PN10 lm 24.00 0.00
1.1.7 Supply and installation of Dry Latrine Squatting Pan – Ordinary Type Heavy-duty vitreous china or FRP pan, no water seal, shallow profile with anti-splash lip, drop hole min. 180mm with pipe connection to the pit as shown on the drawing. Includes fixing to concrete slab. No water supply connection." № 10.00 0.00
1.1.8 Supply and installation of Dry Latrine Squatting Pan – PWD Type Accessible design for persons with disabilities. Heavy-duty FRP or china with raised footrests, pan rim height ≤200mm from floor. Includes stainless steel grab bars (wall-mounted, vertical & horizontal). Drop hole min. 200mm with pipe connection to pit as shown on the drawing. No water supply connection." № 2.00 0.00
Total Carried to summary USD 0.00
2 WASTE WATER DRAINAGE SYSTEMS
2.1 Pit Latrine Ventilation Pipe (DN 100) – Supply, install, and commission one uPVC ventilation pipe, DN 100 mm (4 inch), conforming to ISO 1452-1, including: pipe extending from 300 mm above pit floor to 1.0 m above highest roof peak, solvent welded joints, galvanized brackets at 2 m maximum intervals, weatherproof cowl (turbo vent or 180° bend with bird screen), stainless steel insect mesh (12 mm aperture) at top, and fly-proof mesh (2 mm aperture) at pit entry. № 4.00 0.00
2.1.2 Handwashing Station (Standard) – Supply, install, and commission one handwashing station comprising: concrete basin (2800×400×200 mm), twelve (12)(six (6) on each side) lever-operated chrome-plated brass tap, two liquid soap dispenser (500 mL), supply piping PPR and uPVC drainage piping to soak away pit. set 2.00 0.00
2.1.3 Dito No 2.1.2 but for drinking water fetching and with six(6) faucet at one side only. set 1.00 0.00
2.1.4 Soak Pit – Supply, excavate, construct, and commission one soak pit for handwashing station drainage, including excavation, stone/gravel filling, perforated pipe inlet, geotextile fabric lining, and covered top with inspection port. Dimensions as per standard design. set 3.00 0.00
2.1.5 Oil/Grease Interceptor (Concrete/Masonry Construction) Supply, construction, and installation of a reinforced concrete or masonry gravity grease interceptor for pre-treatment of greywater from handwashing basins prior to discharge to the soak-away pit. Works include excavation to required depth, installation of a 100-liter minimum capacity two-compartment interceptor constructed of precast or cast-in-place reinforced concrete (minimum 150 mm thick walls) or brick/block masonry laid in Portland cement mortar (minimum 125 mm thick walls) with waterproofed interior surface to ensure watertightness . The interceptor shall include: (i) an inlet pipe with a removable coarse screening basket or silt trap for capturing solids and food debris ; (ii) a baffle wall or vertical partition with a lower communication opening to allow gravity separation based on the density difference between water and grease/oil ; (iii) an outlet pipe with a T-shaped or baffled fitting to retain floating grease; (iv) a removable, lockable cast iron or reinforced concrete cover (minimum 400 mm diameter) with access for inspection, cleaning, and maintenance ; and (v) a manhole or access step for safe entry during maintenance . The rate shall include all labour, materials, tools, excavation, backfill, compaction, concrete works, reinforcement, formwork, waterproofing, pipe connections (inlet and outlet), cover, and testing for watertightness . Construction shall comply with WaterAid Technical Guidelines, Sphere Handbook (2018), and relevant IPC provisions for grease interceptors. ls 2.00 0.00
2.1.6 Infiltration Test for Soak-Away Design Carrying out of field infiltration (percolation) test at proposed soak-away pit location to determine site-specific soil infiltration rate for the design of greywater disposal system. Works include excavation of one trial pit (minimum 0.5m × 0.5m × 0.5m), saturation of the pit, measurement of water level drop over a minimum period of 4 hours, calculation of infiltration rate (mm/hr or L/m²/day), and production of a signed test report with results and recommendations for soak-away sizing. The test shall be carried out in accordance with WaterAid Technical Guidelines and Sphere Handbook (2018) standards. The rate shall include all labour, tools, water for testing, site supervision, and report preparation. ls 2.00 0.00
Total Carried to summary USD 0.00
3 ROOF RAIN WATER DOWNPIPING SYSTEM
3.1 Rainwater Downpipe DN 80 (Toilet Block) – Supply, install, test, and commission one uPVC rainwater downpipe, DN 80 mm nominal diameter, conforming to ISO 1452-1 or AS/NZS 1260, minimum wall thickness 2.0 mm. Include stainless steel leaf guard (5 mm mesh) at roof inlet, galvanized pipe brackets (vertical spacing 1.8 m maximum, horizontal spacing 1.0 m maximum), UV-reflective light-colored oil paint coating (white/light grey) conforming to ISO 4892-2 on all exposed sections, and discharge splash block at base. Complete from roof outlet to ditch/splash block. ml 20.00 0.00
Total Carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.7.1-Water Reservior Plat form & Pump Control Switch Room-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A 0.00
B. SUPER-STRUCTURE
1 BLOCK WORK USD 0.00
2 ROOFING USD 0.00
3 METAL WORK USD 0.00
4 STEEL STRUCTURE USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No additional allowance for working space to be considered for measurement. The site clearing area shall be the net built-up area including aprons, open ditch, entrance step and ramp. m2 74.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for the ground floor from the Average Natural Ground Floor Level (A.N.G.F.L.) to a depth not exceeding 150 cm. The volume of excavation shall be measured only over the net built-up area of the building footprint, excluding aprons, open ditches, and ramps. Working allowance: An additional 0.50 m width on each side of the excavation shall be included to allow for proper working space. Reference level (A.N.G.F.L.): The A.N.G.F.L. is defined as the average of the topographic ground levels taken at the building footprint prior to any excavation works, reduced by 20 cm to account for above work item site clearing. m3 23.00 0.00
1.3 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level. Note: measurement shall include 150 cm working space in each side for trench excavation. m3 21.00 0.00
1.4 Back fill under hard core and around the building with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 12.00 0.00
1.5 Back fill around masonry wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 8.00 0.00
1.6 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material. Disposal shall be measured as the net volume arising from the void created by the excavation, less excavated material backfill, filled and wheel spread within site or left stockpiled. m3 58.80 0.00
1.7 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 34.00 0.00
1.8 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone.only under concrete channel. m2 40.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately.
2.1 5 cm thick lean concrete in grade/class C-5 concrete, minimum cement content of 150 kg/m3 :
A. Under ground floor slab m2 21.00 0.00
B. Under masonry foundation wall m2 41.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
A. In grade beam m3 2.05 0.00
B. In 10 cm thick slab m2 40.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
To grade beam m2 21.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
A. For grade beam
Dia 8 mm deformed bar Kg 129.00 0.00
Dia 12 mm deformed bar Kg 205.00 0.00
B. For slab on grade
Dia 8 mm deformed bar Kg 159.00 0.00
Total carried to summary USD 0.00
3.1 50 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 21.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
1.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for pointing. price shall include pointing m2 42.00 0.00
Total carried to summary USD 0.00
2.1 Supply and fix approved standard pre-painted 0.35mm thick corrugated iron sheet (C.I.S.) roofing cover fixed to "RHS " purlin with 5.5mm diameter carbon steel self drilling fasteners/ J-bolt with washer. Price shall include all necessary fixing accessories like outside foam closure, self drilling fasteners, drip trim, corner trim, eave trim, girt trim, girt clip, and all others necessary fixing accessories. (purlin measured separately). All detail and installation shall be in accordance with the manufacturer's instructions, drawing and Engineers approval. (roof shall measured in horizontal projection). m2 14.00 0.00
Total carried to summary USD 0.00
3.1 Double-leaf metal door constructed from 40×40×3 mm RHS steel for vertical and horizontal framing, fully welded and braced with similar RHS sections as shown in the Architectural drawings. Door to be infilled with galvanized steel wire mesh 2.5 mm dia. at 25 mm c/c, welded to frame. Include all necessary welding, surface preparation, one coat of primer, and two coats of synthetic enamel paint to all steel surfaces. All work to conform to detailed drawings and relevant standards.
A. Door D1 size 100 x 100 cm. no 1.00 0.00
B. Door D2 size 170 x 150 cm. no 1.00 0.00
3.2 Wire mesh covering for pump control switch side walls made of galvanized steel wire mesh 2.5 mm diameter, spaced at 25 mm c/c, fixed securely to RHS structural frame using appropriate clamps or welding as shown on the drawings. The work includes cutting, fitting, welding (where required), surface preparation, one coat of metal primer, and two coats of synthetic enamel paint on all steel members. All materials and workmanship shall comply with the relevant standards and detailed drawings. m2 9.68 0.00
Total carried to summary USD 0.00
4 STEEL STRUCTURE
4.1 Supply, fabricate, assemble, and erect steel structures using RHS and CHS profiles as per structural drawings. The work includes all necessary cutting, welding and jointing required for complete assembly. The work shall also includes apply one coat of anti-rust primer after fabrication, followed by two coats of synthetic enamel paint for final protection and appearance after completion of all finishing works. Note: unless it is necessary the steel profile length shall be one unit with the limit of factory standard. Price shall include Materials, labor, fabrication, erection, welding, surface preparation, painting, and all accessories required for a complete and finished steel structure as per the drawings.
A. Steel Structure Column
Steel structure columns are vertical primary load-bearing members, transferring axial loads (and occasionally bending) from trusses to foundations. Since columns are in direct contact with water during cleaning, apply bituminous damp-proof paint at the column base up to a height of 300 mm (30 cm) to prevent corrosion and moisture penetration.
A.1 steel structure column using two RHS sections, 60 × 60 × 3 mm. not welded part single unit. kg 86.00 0.00
B. Steel Structure Column Beam
The beam shall be welded column to column just below the top plate level where truss and column connected. At the end of the beam where there is no steel column. it connected with the existing building it will be fixed with plate at the concrete column/tie beam
B.1 RHS 60 x 60 x 3mm beam kg 195.00 0.00
C. Steel rafter
Steel trusses and rafter shall be fabricated from RHS members as per structural drawings. Truss members to be cut, and welded as per design, ensuring structural stability and alignment. Surface protection: apply one coat of anti-rust primer after fabrication, followed by two coats of metal paint after erection and completion of all finishing works. All works shall comply with structural drawings, engineering specifications, and relevant standards.
C.1 RHS 80 x 60 x 3mm rafter kg 69.00 0.00
D. RHS Purlins 0.00
D.1 RHS 80 x 40 x 3mm purlin fixed to upper truss member with 100 x 40 x 3mm L= 60mm angle iron. Price include angle iron. kg 106.00 0.00
4.2 Sundry (miscellaneous) Steel Part
Prepare the surface and fixing in position all the necessary sundry parts. The place shall be clean and free from dust. All detail and installation shall be in accordance with the manufacturer's drawings.
A.1 Base plate size 150 x 150 x 8mm with 4 dia.18 slotted holes for dia. 16 J-bolt No 8.00 0.00
A.2 Metal plate 40x200x3 welded to truss and bolted to angle iron-2 ∅8mm bolt to connect angle iron to metal plate No 32.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.7.2.1-Pump Control Switch Room-1-Electrical
ITEM DESCRIPTION UNIT QTY RATE TOTAL
Supply and install:-
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Factory assembled and tested surface-mounted Sub distribution Board, SDB-PH1 in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories, and consisting: 0.00
1pc main MCB of 20A, 2P, Icu=10KA, coupled with RCD ,300mA Type S/ Time delayed 0.00
2pcs RCBO of 16A, 2P, Icu=6KA , 30mA 0.00
1pcs MCB of 10A, 2P, Icu=6KA
2pcs MCB of 16A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer 0.00
with 25% reserve space and busbar of 63A, 3ph+N No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 1.00 0.00
1.3 Light Fittings and Lamps 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 2.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Single pole Switch water proof IP44 No 1.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 2.00 0.00
1.6 Power outlet points.
1.6.1 16A/1P power outlets point for domestic water pump fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 1.00 0.00
1.6.2 100A/3P power outlets point for Fire Pump set control panel fed through XLPE insulated fire rated conductors of 3x35/16+16 mm² inside PVC conduits of 100mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 1.00 0.00
1.7 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.7.1 16A ,1ph ,230V 2p+e socket out let water proof IP44 No 2.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.7.2.2-Pump Control Switch Room-2-Electrical
ITEM DESCRIPTION UNIT QTY RATE TOTAL
Supply and install:-
1.1 DISTRIBUTION BOARDS 0.00
1.1.1 Factory assembled and tested surface-mounted Sub distribution Board, SDB-PH2 in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories, and consisting: 0.00
1pc main MCB of 20A, 2P, Icu=10KA, coupled with RCD ,300mA Type S/ Time delayed 0.00
2pcs RCBO of 16A, 2P, Icu=6KA , 30mA
1pcs MCB of 10A, 2P, Icu=6KA 0.00
2pcs MCB of 16A, 2P (spare) Icu=6KA 0.00
1Pc of surge arrestor of 20KA Type 2, coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
with 25% reserve space and busbar of 63A/1P+N. No 1.00 0.00
1.2 Light & Switch Points 0.00 0.00
1.2.1 Surface/Recessed mounted Light points fed through PVC insulated conductors of 3x2.5mm2 for light points and switches respectively inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 1.00 0.00
1.3 Light Fittings and Lamps 0.00
Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing, of LED Type with 50,000 hr lifetime, sourced from well reputed global manufacturer. IEC 60969 standards or equivalent and type approved. 0.00
1.3.L2 LED Batten Light: L1200, 30W, 3600 lumens (main), 4000K, CRI > 80, ceiling-mounted, polycarbonate, IP66, flicker-free, water proof.for outdoor instalation. No 2.00 0.00
1.4 Extra Over Light Points for Flush/Surface Mounted Switches approved BS standard. 0.00
Price shall include wiring using 2.5mm2 wire size, conduits, junction boxes with covers, insulating screw cap connectors and wall cover all complete. 0.00
1.4.1 Single pole Switch water proof IP44 No 1.00 0.00
1.5 Socket outlet points 0.00 0.00
1.5.1 Flush mounted socket outlet points fed through PVC insulated conductors of 3x2.5mm2 inside and including rigid PVC conduits of 16mm diameter including junction boxes with covers insulating screw cap connectors complete. No 2.00 0.00
1.6 Power outlet points.
1.6.1 16A/1P power outlets point for domestic water pump fed through PVC insulated conductors of 3x2.5mm² inside PVC conduits of 16mm inner diameter including junction boxes with covers and insulating screw cap connectors complete. compatible standards or equivalent and type approved. No 1.00 0.00
1.7 Extra Over Socket Points for Flush/Surface Mounted Socket Outlets approved BS standard. 0.00 0.00
1.7.1 16A ,2P,230V 2p+e socket out let water proof IP44 No 2.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.8-Solid Waste Collection-Civil
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK USD 0.00
2 CONCRETE WORK USD 0.00
3 MASONRY WORK USD 0.00
SUB-TOTAL A 0.00
B. SUPER-STRUCTURE
1 BLOCK WORK USD 0.00
SUB-TOTAL B USD 0.00
TOTAL A+B CARRIED TO GRAND SUMMARY USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
A. SUB-STRUCTURE
1 EXCAVATION & EARTH WORK
A) Prices generally are to include for provision of all materials for carrying out the work except where item are specifically described as "measured separately".
B) Prices generally are to include for all necessary scaffolds, temporary screens, guard rails and other protective measures for proper execution of the work described and for the proper protection of the existing surrounding building, persons and others.
C) Prices generally are to include for making good of any damage or disturbance caused by the execution of the work described.
D) Prices generally are to include for the clearing away and removal from the site .
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No additional allowance for working space to be considered for measurement. The site clearing area shall be the net built-up area including aprons, open ditch, entrance step and ramp. m2 30.00 0.00
1.2 Bulk excavation in ordinary soil to reduce level for the ground floor from the Average Natural Ground Floor Level (A.N.G.F.L.) to a depth not exceeding 150 cm. The volume of excavation shall be measured only over the net built-up area of the building footprint, excluding aprons, open ditches, and ramps. Working allowance: An additional 0.50 m width on each side of the excavation shall be included to allow for proper working space. Reference level (A.N.G.F.L.): The A.N.G.F.L. is defined as the average of the topographic ground levels taken at the building footprint prior to any excavation works, reduced by 20 cm to account for above work item site clearing. m3 9.00 0.00
1.3 Trench excavation for stone masonry foundation wall in ordinary soil to a depth not exceeding 150 cm starting from reduced level. Note: measurement shall include 150 cm working space in each side for trench excavation. m3 9.00 0.00
1.4 Back fill under hard core and around the building with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 8.00 0.00
1.5 Back fill around masonry wall with selected material, well rammed in layers of 20 cm thick and compacted at dry density and optimum moisture content to achieve 95% standard proctor. m3 3.00 0.00
1.6 Redig from spoil heap , load and cart away surplus excavated material to a suitable pit as may be found by the contractor and with in the acceptable range of the city administration. shall make sure that proper permit is secured for the dump site and must make sure that the client is protected from liability of unlawful damping of cart away material. Disposal shall be measured as the net volume arising from the void created by the excavation, less excavated material backfill, filled and wheel spread within site or left stockpiled. m3 24.00 0.00
1.7 Supply and fix construction joint between grade slab with 1 cm chip wood or styropor. Price include once the concrete floor completed the expansion joint shall be filled with joint filler/sika or with fiber board) in addition at ramp and entrance construction joint shall be covered with aluminum cap. ml 13.00 0.00
1.8 25 cm thick basaltic or equivalent stone hard core well rolled, consolidated and blinded with crushed stone.only under concrete channel. m2 11.00 0.00
Total carried to summary USD 0.00
2.0 CONCRETE WORK
Particular attention is to be given to the following remarks along with the technical specification and method of measurement. The quality of ingredient materials must satisfy the standard quality requirements and concrete design mixes shall be prepared and certified by laboratory testing. During casting samples should be taken for laboratory testing following specification requirements.
Concrete:- The specified concrete strength must be confirmed by laboratory test.
Reinforcement bars:- The specified strength and other related properties of reinforcement bar must be confined either by manufacturer's catalogue/manual or/ and by laboratory test.
The Contractor shall conduct the compressive strength of concrete mix design for each types of concrete grade for the contract specification ahead of concrete placing for the permanent structure. The purpose of the required mix design is to determine the proportion of ingredient material that, when properly mixed and properly placed, will produced a mix that meets the requirements for place ability, consistency, durability, and appearance. And the test result will provided as a reference guide for the necessary quality assurance inspection.
In case of using Chemical Admixtures: The Contractor shall provide admixtures certified by manufacturer to be compatible with other admixtures and that will not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride.
The costs of Concrete shall include making, storing and testing of concrete test cubes as required and providing cube molds necessary for the purpose and for submitting reports of the tests to the Engineer.
Price for concrete shall include placing concrete by whatever means, for vibrating with mechanical vibrators. Formwork and reinforcement shall be measured separately.
2.1 5 cm thick lean concrete in grade/class C-5 concrete, minimum cement content of 150 kg/m3 :
A. Under ground floor slab m2 11.00 0.00
B. Under masonry foundation wall m2 9.00 0.00
2.2 Reinforced concrete grade/class C-30 (With a 28 day 150mm cube crushing strength of 30Mpa), cast into formworks and vibrated around rod reinforcement bars. The Cement type shall be sulfate-resisting (SR) cement conforming to EN 197-1, Type CEM III/A 42.5 N or equivalent. Maximum water/cement ratio: 0.50. Minimum cement content: 340 kg/m³. Formwork and reinforcement bars are measured separately. The work shall also include supply and apply high-quality penetrating hydrophobic sealer to all concrete elements in contact with soil, including but not limited to footings, foundation walls, grade beams, slab-on-grade, embedded columns, pedestals, and other buried concrete structures. The sealer shall be silane-, siloxane-, or siliconate-based water repellent, capable of penetrating the concrete substrate and providing long-term protection against moisture ingress, capillary rise, water absorption, chloride penetration, and deterioration. The rate shall include surface preparation, cleaning, application in accordance with the manufacturer's recommendations, all labor, materials, equipment, testing, and incidental works necessary for complete installation.
A. In grade beam m3 1.10 0.00
B. In 10 cm thick slab m2 11.00 0.00
2.3 Provide, cut and fix in position sawn structural wood or steel formwork which ever is appropriate; The work shall include design, erect, shore, brace, and maintain formwork, according to EBCS 2-1995, to support vertical, lateral, static, and dynamic loads, and construction loads that might be applied, until structure can support such loads. The work shall be so concrete members and structures are of size, shape, alignment, elevation, and position indicated, within tolerance limits of ACI 117. all forms shall be tight enough to prevent loss of concrete mortar. during fabrication forms shall be for easy removal without hammering or prying against concrete surfaces. Provide crush or wrecking plates where stripping may damage cast concrete surfaces. Provide top forms for inclined surfaces steeper than 1.5 horizontal to 1 vertical.
To grade beam m2 9.00 0.00
2.4 Steel bar reinforcement according to structural drawings. Reinforcement shall be free from dirt, oil, grease, paint, readers, etc and any other substances which may affect the reinforcement and concrete bond (price include cutting, bending, placing in position and tying wires.
Dia 8 mm deformed bar Kg 33.00 0.00
Dia 12 mm deformed bar Kg 60.00 0.00
B. For slab on grade
Dia 8 mm deformed bar Kg 47.00 0.00
Total carried to summary USD 0.00
3.1 50 cm thick Basaltic or equivalent stone masonry foundation wall bedded in cement sand mortar (1:4) below NGL.. m3 8.00 0.00
Total Carried to summary USD 0.00
B. SUPER -STRUCTURE
Walls shall be constructed from decorative face red burnet brick & class "B" HCB . The bricks & HCB shall be selected for their consistency in dimensions, shapes, angles and strength, They should be free from crakes or any other defects and the surface characteristics of the bricks shall be in such a way that good key for pointing is obtained on both side.
1.1 Supply and construct non decorative/plainred burnt 20cm thick (double) brick wall, built in approved red burnt clay bricks laid in cement-sand mortar (1:3), including all labor, materials, scaffolding, jointing, pointing, curing, cutting, waste, and all necessary accessories. Wall shall be constructed to the lines, levels, patterns, and details shown on the drawings, both side left for pointing. price shall include pointing & concrete copping on top of the short wall m2 40.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.9-Site Works-Civil
1 Gravel Finish- Compound Surface USD 0.00
2 Perimeter Fence with Gate USD 0.00
3 Landscaping Work USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 Interlocking Tile for Walk & Car way way
1.1 Clearing of the site to remove top soil and other rubbish materials to an average depth of 20 cm. Note: No allowance for working space to be considered for measurement. The site clearing area shall be the net pavment area including curbstone. m2 2,358.20 0.00
1.2 Bulk excavation in ordinary soil to reduce level for ground floor from Average Natural Ground Floor Level (A.N.G.F.L) to a depth not exceeding 150 cm. Note: measurement shall include the net area of the site clearing work that includes curb stone. The average natural ground floor level shall mean the average topographic level before any excavation work commence in which the building will rest and minus 20 cm thick site clearing. The depth of excavation shall be as per the structural drawing general note. m3 1,179.10 0.00
1.3 Load and cart away surplus excavated material to a suitable damping area allowed by the municipality not more than 5km from the site. m3 1,650.74 0.00
1.4 Selected fill to 95% MDD, including watering and rolling as shown the drawing m3 1,179.10 0.00
1.5 Supply and place crushed stone base course (C-4) 100 mm thick, including spreading, watering, and compaction to 95% MDD. m3 235.82 0.00
1.6 Supply and lay clean coarse sand bedding layer, 30–50 mm thick, leveled and compacted. m3 117.91 0.00
1.7 Supply and lay hand-dressed natural basalt/granite cobblestones (approx. 150×150×150 mm), tightly packed with joints filled with sand or cement-sand slurry as directed by the Engineer. m2 2,358.20 0.00
1.8 Edge restraint using concrete curb (150×400 mm) including excavation, formwork, placing, and finishing. ml 622.00 0.00
1.9 Pointing and final compaction of cobblestone surface including sweeping fine sand into joints and watering. m2 2,358.20 0.00
1.10 Supply, fabricate and fix steel bollards with steel chains for physical protection at conflict points, as follows: Bollards: Fabricated from 100 mm diameter galvanized steel pipe (CHS) 900 mm height above ground level fixed to 300 x 300 x 300 mass concrete foundation anchor with angle iron as shown on the detail drawing the bollard specing shall be c/c 1000mm. the space between the bollards shall be fixed with chain made of Heavy-duty 6 mm diameter steel chain, galvanized finish, connected to bollards using industrial-grade eye-bolts/hooks at the specified height. Fabrication, welding, installation, and fixing strictly as per drawings and engineer’s instructions. Price includes all materials (steel sections, chains, anchor bolts), excavation, concrete foundation, welding, surface preparation (grinding, de-scaling), one coat of anti-rust primer, two coats of exterior-grade metal paint, transport to site, and all necessary labor, tools, and equipment to complete the installation. Ml 159.00 0.00
Total Carried to Summary (USD) 0.00
2.1 Supply, fabricate, and install galvanized steel wire mesh perimeter fence comprising 40 × 40 × 2 mm angle iron vertical posts spaced at 2800 mm centers, fixed in concrete pad foundations, with top, middle and bottom horizontal rails (30 × 30 × 2 mm angle iron). The fence infill to be galvanized steel wire mesh (Ø 2.5 mm, 50 × 50 mm grid) securely fixed to the frame. The work also include three rows of barbed wire for security. The rate shall include excavation, concrete works, anti-rust treatment, metal painting,fabricated from similar materials, complete with all accessories and incidental work to complete the work, in accordance with the detail drawing,specifications and Engineer’s instructions. ml 366.00 0.00
2.2 Supply, manufacture & errect main entrance and exit metal door. Price shall include preparation and all necessary incidenatal work to complete the work. Alla are as per the Architectural and structural detail drawing. The work also include gate concrete post as shown in the detail structural drawing No 4.00 0.00
Total Carried to Summary (USD) 0.00
3 LANDSCAPING WORKS
3.1 Excavate the top soil to an average thickness of 20cm.for greenery part m² 761.00 0.00
3.2 Bulk excavation to remove the ordinary soil depending up on the actual level but not exceeding 50cm from reduced ground level. m3 380.50 0.00
3.3 Load and cart away surplus excavated material to a suitable damping area allowed by the municipality not more than 5km from the site. m3 532.70 0.00
3.4 Supply, well decomposed animal manure or equivalent organic material to be mixed with the topsoil averagely 300mm and to use in backfilling of planting pits.Price shall include all the necessary works to complete the work. Provide 1kg sample and details of supplier With quotation for Landscape Architect’s approval. m³ 228.30 0.00
PLANTING INSTALLATION OF GROUND COVERS:
3.5 Provide and plant grass as selected by the landscape architect. price includes gras as per the detail Architectural drawing. m2 543.00 0.00
3.6 Maintenance of lawn , grass, trees, shrubs, seasonal flower bed, other plantation and horticultural operations for weeding, watering, spreading of manure, good earth , fertilizers, spray of insecticides, fungicides, hoeing, pruning of tree/shrubs/hedge plants grassing garden swords, anti-termite treatment. Rates to include cost of material, all labor, tools & tackles, cost of manure, earth, fertilizer, pesticides etc. and also providing complete arrangement at site/sites for grass cutting by brand new power run lawn mower with skilled machine man & labor, diesel, lubricant to ensure mowing on barns and by manual labor through garden sward on the slop of under pass of the grass at least 3 times / month complete Month 2.00 0.00
Total Carried to Summary (USD) 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.10-Site Works-Electrical
ITEM DESCRIPTION UNIT QTY RATE TOTAL
1 Manhole for Electrical Systems
1.1 Construct rectangular double red burnt brick electrical manholes of internal dimensions 800mm × 800mm × 600mm (MH-2) in accordance with the detail drawings and specifications. The manhole shall comprise 250mm thick double red burnt brick masonry walls, internally plastered with cement-sand mortar, a 100mm thick reinforced concrete base slab, and a 100mm thick removable reinforced concrete cover slab complete with flush-type cover, all as approved by the Engineer. The rate shall include excavation to the required depth, disposal/cart-away of surplus excavated material, back-filling and compaction around the structure, supply and placement of concrete, reinforcement, form-work, brick masonry, plastering, curing, and all associated civil works, labor, materials, tools, and incidentals necessary for the complete and proper construction and functioning of the electrical manhole system. Set 3.00 0.00
1.2 uPVC Pipes and Ducts
1.2.1 100mm diameter uPVC m 60.00 0.00
1.2.2 50mm diameter uPVC m 500.00 0.00
1.3 Earth Network (Grounding System)
1.3.1 Grounding pit 600x600x700mm with top cover inscribed "Grounding pit" as per the detail drawing. (MH-1) No 6.00 0.00
1.3.2 Bare ground connecting copper cable of 1x70sq.mm ml 450.00 0.00
1.3.3 Earthing electrode diameter 20mm and length 3000mm 0.00
copper rode 0.00
Note: If the earth resistance is more than 10 ohms 0.00
add additional electrode spaced at length of 0.00
the electrode (spaced at a minimum of 5m apart) No 6.00 0.00
1.3.4 Equipotential Bonding - Supply and installation of complete equipotential bonding system with appropriate size equiptential earth bar to be palce near to the main board as shown in the drawing, for all applicable exposed and extraneous metallic parts, including structural steelwork, metallic water pipes, HVAC/MEP services, and other metallic services, using appropriately sized copper bonding conductors, bonding clamps, terminals, connectors, and all necessary accessories, connected to the Main Earth Bar in accordance with the design, applicable standards, and drawings. LS 1.00 0.00
1.4 DISTRIBUTION BOARDS 0.00
1.4.1 Factory assembled and tested surface-mounted Central main distribution Board, CMDB in sheet steel enclosure with lockable door including all necessary fixing and connecting accessories, and consisting:
1pc main MCCB of 160A, 3P+N/2, adjustable magnetic (short-circuit) protection only, Icu=16KA
1pcs MCCB of 100A, 3P+N/2, adjustable magnetic (short-circuit) protection only, thermal/overload protection disabled or excluded, suitable for fire pump feeder, Icu=10KA
1pcs MCCB of 100A, 3P+N/2, Icu=16KA
1Pc of surge arrestor of 40KA Type 1 , coupled with appropriate backup overcurrent protection/disconnection device where required by the SPD manufacturer
3 pcs current meters of 160/5A with 6A fuse
1 pc Volt meter of 500V with selector switch and 6A fuse
1 pc frequency meter
with 25% reserve space and busbar of 200A/3ph+N. No 1.00 0.00
1.4.2 Factory-assembled and tested surface-mounted main distribution Board (MDB) in a sheet steel enclosure with a lockable door, including all necessary fixing and connecting accessories, and consisting:
1pc main MCCB of 100A, 3P+N/2 , Icu=10KA coupled with 500mA, RCD. Type S/ Time delayed
1pcs MCB of 40A, 4P, Icu=10KA
1pcs MCB of 32A, 4P , Icu=10KA
1pcs MCB of 25A, 4P , Icu=10KA
2pcs MCB of 20A, 2P, Icu=6KA
2pcs MCB of 16A, 2P Icu=6KA
2pcs MCB of 25A, 4P (spare) Icu=10KA
with 25% reserve space and busbar of 125A/3ph+N. No 1.00 0.00
1.5 Feeder Cables and PVC pipes 0.00
XLPE Insulated PVC Sheathed 0.6/1KV power cable (IEC 60502-1), or approved equivalent to be drawn inside riser shaft or PVC conduit (measured elsewhere, tentative) and of:- 0.00
Cable sizes include: 0.00 0.00
1.5.1 3X95/50+50 mm2 From TX to CMDB m 10.00 0.00
1.5.3 3X35/16 mm2 CMDB to Firefighting CP ( Fire rated cable) m 45.00 0.00
1.5.4 4x16 mm2 From MDB to SDB - VM m 30.00 0.00
1.5.5 4x10 mm2 From MDB to SDB - CM, m 180.00 0.00
1.5.6 4x6 mm2 From MDB to SDB-MPH m 150.00 0.00
1.5.7 3x4 mm2 From MDB to SDB SR1, m 10.00 0.00
1.5.8 3x4 mm2 From SDB-MPH to UPS, from UPS to SDB - UPS m 20.00
1.5.9 2x4 mm2 From MDB to SDB -PH1, From SDB-MPH to SDB-PH2 & SDB-SR2 m 200.00 0.00
1.5.10 3x2.5 mm2 From SDB -PH-1 to SDB-TO-1, From SDB -PH-2 to SDB-TO-2 m 30.00 0.00
1.5.11 1x16mm2 earthing cable from Fire pump CP to Earth rode, From SDB-VM to Earth rode m 20.00
1.5.12 1x10 mm2 from SDB-CM to Earth rode, m 15.00
1.5.13 1x6mm2 earthing cable From SDB-MPH to Earth rod m 15.00
1.5.14 1x4mm2 earthing cable From SDB-PH1, SDB-PH2, SDB-SR2 to Earth rode m 35.00
1.6 Light Fittings and Lamps 0.00
. Specified type or equivalent light fittings with lamps: All light fitting shall be according to the drawing. IEC 60969 standards or equivalent and type approved 0.00
1.6.SL1 LED Solar Street Lights for Outdoor, at least 15000 Lumens DA high-brightness, all-in-one solar street light for perimeter lighting, powered by sunlight with no electricity costs. Key Specifications Brightness: ≥15,000 lumens (bright as daylight) Light Type: LED (SMD 2835 or CREE 3030 chips) Color: Cool white (6000K–6500K) Solar Panel: 120-watt monocrystalline (charges in 6 hours) Battery: LiFePO4, ≥7-year lifespan, 3-day backup capacity. Operation: Dusk-to-dawn (auto on/off with daylight sensor) Motion sensor (full brightness on movement, dims to save energy) Remote control (adjust brightness, set timers) Weatherproof: IP65 (waterproof, dustproof, works in rain or heat) Material: Aluminium housing, tempered glass cover Runtime: 11 hours after 6-hour charge; up to 18 hours in dim mode Installation: Pole or wall mount (6ms height), no wiring needed Durability: Works in -22°F to 140°F; 50,000+ hour lifespan Warranty: 3–5 years, The luminaire shall incorporate an integrated surge protection device (SPD), minimum Type II, suitable for outdoor LED lighting applications, with a nominal discharge current (In) of at least 10 kA and a maximum discharge current (Imax) of at least 20 kA. Complete with all accessories necessary for installation and commissioning. No 21.00 0.00
1.6.2 Supply, install, test, and commission a 6 m high hot-dip galvanized octagonal steel pole, complete with luminaire outreach arm, suitable for supporting an integrated solar LED street lighting system including battery box at 5m height, and all associated mounting accessories. The pole shall have a base diameter of 140 mm and a top diameter of 60 mm, and shall be supplied complete with base plate, foundation anchor bolts, templates, and all necessary fittings. The pole shall be designed and manufactured in accordance with EN 40-3-1 and rated for a reference wind velocity of 30 m/s (108 km/h). Complete concrete pole foundation/pad,including setting out, excavation, disposal of surplus material, preparation and compaction of formation, selected backfill and compaction, blinding concrete where required, reinforced concrete, reinforcement steel, formwork, anchor bolts, plate nuts, washers, templates and non-shrink grout; installation, alignment and commissioning of pole, PV panel and luminaire; testing of PV charging, battery operation and lighting performance; and all labor, materials, equipment, transportation, tools and incidentals necessary to provide a complete and operational solar PV lighting system in accordance with the approved drawings and specification Complete in accordance with the drawings and technical specifications. No 21.00 0.00
1.7 Lightning Arrester System
(Eritech or Equivalent)
Shall include all metalic structures in the network with appropriate welding (ventpipes,ducts ,GIS roof & structures, solar PV panels, e.t.c)
1.7.1 Early Streamer Emmision(ESE) Protector SI 60 with mounting mast of H=2.0m and all necessary connecting acessories. No 2.00 0.00
1.7.2 25x3mm copper tape with all necessary roof connecting accessories m 60.00 0.00
Down conductor 0.00
1.7.3 25 x 3mm insulated copper tape with vertical supportings every 0.3m to the wall & all the necessary accessories coordinate the routing of down conductors with the building external skin and architectural features. ml 30.00 0.00
1.7.4 Lightening Event counter to be installed on the down conductor to count number of lightening strikes. No 4.00 0.00
1.7.5 Test point (junction box) with all necessary connection acessories to connect the down conduction with the earthing bare copper wire. at least 1.5m above floor finish. No 4.00 0.00
1.7.6 Prefabricated Crowsfeet 25x3mm tinned coper tape. In complienc with IEC-EN 62561-2, with L1=1000mm and L2= 3000mm No 6.00 0.00
1.7.7 50 x 50 x 50 cm test pit with top cover inscribed "Test pit" as per the detail drawing( MH-3) No 6.00 0.00
1.7.8 1 x 70 sq.mm bare copper wire ml 20.00 0.00
1.7.9 Earthing electrode Diameter 16mm & 1500mm long copper rod No 6.00 0.00
1.9 FIRE ALARM SYSTEM 0.00
1.9.1 16A/2PPower outlet point for fire alarm control panel and repeater panel , fed through fire rated cable of 3x2.5mm2 inside and including rigid PVC conduits of 19mm diameter including junction boxes with covers insulating screw cap connectors complete. No 2.00 0.00
1.9.2 RS-485 communication cable to connect FACP and Repeater panel. ml 170.00 0.00
1.9.3 Conventional Fire alarm Control Panel, Minimum of 3 zones Complete with power supply & battery backup, and RS-485 communication port for repeater panel. No 1.00 0.00
1.9.4 Conventional Fire alarm repeater Panel, 3 zones Complete with power supply & battery backup and RS-485 communication port. No 1.00 0.00
1.9.5 Smoke detector; with Flash Scan and Detector Base, Complete No 12.00 0.00
1.9.6 Fire alarm sounder strobe (RED), for outdoor use IP66 No 6.00 0.00
1.9.7 Outdoor manual call point complete with a lockable, transparent anti-vandal protective cover with local audible warning on cover lifting. The manual call point shall be resettable type, suitable for outdoor installation, minimum IP66 and IK10, UV-resistant, corrosion-resistant, and compatible with the fire alarm system. The unit shall comply with EN 54-11, and shall be complete with weatherproof mounting box, fixing accessories. No 12.00 0.00
1.9.8 Flush Mounted Fire Alarm Points (smock detectors, manual call points, sounders, and sounder beacons) fed in 2 x 2.5sq. mm fire-resistant, low-smoke, zero-halogen (FRLS/LSZH) fire alarm cable. For internal building installations, cables shall be installed in 19 mm diameter FRLS PVC conduits concealed or surface-mounted as specified. For external inter-building connections, cables shall be installed in 50 mm diameter heavy-duty uPVC conduits buried underground between blocks, complete with all necessary conduit accessories, including bends, couplings, adaptors, junction/pull boxes, warning tape, and draw wire No 30.00 0.00
1.9.9 Supply and installation of an end-of-line resistor, compatible with the specified fire alarm control panel and associated conventional detection/alarm circuits, complete with suitable enclosure/base, terminals, identification label, and all accessories required for proper termination and supervision of the circuit. Resistor value shall be as specified/ recommended by the fire alarm system manufacturer and shall be installed at the electrically final device/end of each supervised circuit. This includes testing, commissioning, and integration with the fire alarm system. No 3.00 0.00
1.10 Documentation 0.00
. Engineering, electrical installation as built drawings and O&M manuals. Qualified Set 1.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.11-Site Works-Sanitary
SITE DRAINAGE WORKS
1 SURFACE RAIN WATER DRAINAGE SYSTEM USD 0.00
2 GENERAL ITEMS USD 0.00
SUB-TOTAL (EXTERNAL WORKS) USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 SURFACE RAIN WATER DRAINAGE SYSTEM
The rates for drainage ditches shall include full compensation for excavation, disposal of excavated material, preparation of subgrade, supply and placement of concrete (minimum 25 MPa compressive strength at 28 days) or masonry as specified, forming of trapezoidal or rectangular cross-section, installation of galvanized steel gratings where needed, construction of catch pits with debris screens, joint sealing, curing, and finishing to achieve Manning's roughness coefficient n = 0.017 for concrete ditches and n = 0.025 for masonry ditches, including all formwork, reinforcement where required, and erosion protection measures at outlets. For open ditch sections without covers, the rate per linear meter includes only the items above. For open ditch sections with integrated reinforced concrete covers at public/car way crossings, the rate per linear meter shall additionally include the supply and installation of concrete covers at locations and spacing shown on the drawings, each cover spanning the full ditch clear opening, designed for vehicle overrun loading (BS EN 124 Class B125 for car parks or D400 for carriageways as specified), including 25 mm cement mortar bedding on ditch walls, concrete grade minimum C30/37, reinforcement mesh top and bottom (minimum A142), formwork, non-slip surface finish flush to adjacent grade, galvanized lifting inserts for removal, and curing. No separate payment shall be made for excavation, backfill, disposal, bedding mortar, lifting provisions, or individual covers – the cost of covers at the indicated spacing is deemed included in the per linear meter rate for covered sections. Any gratings or covers damaged during construction shall be replaced at no additional cost.
1.1 Drainage Open Ditch – Supply, excavate, construct, and commission reinforced concrete drainage ditch, rectangular cross-section, with different internal dimensions, concrete grade minimum 25 MPa, smooth finish achieving Manning’s n = 0.017, including excavation to required depth, disposal of surplus material, formwork, reinforcement, joints (with waterstop where needed), and curing.. Provide a minimum slope of 1% or follow the natural ground slope which ever is greater
DITCH-: SIZE[mmXmm] = 600 X 600 ml 210.00 0.00
DITCH-: SIZE[mmXmm] = 200 X 350 ml 360.00 0.00
DITCH-: SIZE[mmXmm] = 400 X600 ml 100.00 0.00
1.2 Dito item No 1.1 but with integrated reinforced concrete cover at public/car way crossings – complete as specified, including all excavation, ditch lining, and concrete covers (BS EN 124 Class B125/D400 loading).
DITCH-: SIZE[mmXmm] = 600 X 600 ml 50.00 0.00
DITCH-: SIZE[mmXmm] = 200 X 350 ml 70.00 0.00
1.20 Catch Pit with Debris Screen – Supply, excavate, construct, and commission one catch pit at ditch junctions or before discharge points, including reinforced concrete construction, minimum 600×600×900 mm deep, removable heavy duty cast iron cover, stainless steel debris screen (12 mm mesh), inlet and outlet connections to adjoining ditches, and concrete base. № 6.00 0.00
Total carried to summary USD 0.00
2 GENERAL ITEMS
2.1 Allow for Testing and commissioning of the entire plumbing installation by a Chartered Mechanical Engineer and obtaining a Test Certificate (3rd party testing to approval of the Engineer) including all off-site and factory testing; inspections to demonstrate compliance with relevant standards, operating the completed installation and submitting all relevant test records and authority approval. LS 1 0.00
2.2 All sanitary fittings supplied shall be provided with a minimum 5 year warranty, issued jointly and severally by the local supplier and the manufacturer. LS 1 0.00
2.3 Allow for preparation of Operationa and Maintenance Manual including site users training for the O & M Maual of all plumbing and mechanical appliances. LS 1 0.00
Total carried to summary USD 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bill No.12-Signage
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 Directory Signs
Design, supply and install international standard Boy's, Girl's & PWD Toilet directional sign complete with pictogram (Girl's, Girl's & PWD toilet sign symbol) plus directional arrow that leading to the toilets. The sign shall also consist text “Boy's , Girl's & PWDToilet.” Sign shall be minimum size 300 mm × 400 mm, high quality tin: tin sign with retro design, metal tin, long-term use, not easy to damage, smooth surface, ...with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 3.00 0.00
2 Directory Signs
2.1 Supply and install main directional sign with text “To each building listed as Signage S-1 Architectural drawing with arrow, made of 3 mm thick photoluminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm for each building direction, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for outdoor mounting with weatherproof finish.Price include civil work to fix the signage post. No 1.00 0.00
2.2 Building departmet sign as the above item the text and size letter hight shall be as per the detail Ar. Signage and the name listed below.
A "Crop Market" sign fixed on the front side elevation No 1.00 0.00
B "Vegetable Market" sign fixed on the front side elevation No 1.00 0.00
C "Multi-Purpose Hall" sign fixed on the front side elevation No 1.00 0.00
D "Toilets" sign fixed on the front side elevation No 2.00 0.00
E "Security House 1 & 2" sign fixed on the front side elevation No 2.00 0.00
F "Solid Waste Collection" sign fixed on the front side elevation No 1.00 0.00
3 Room Identication Signs
Design and supply signage with room number in accordance with this specification and as directed by the Architect. The material shall be made of 3-5mm thick wall mounted Acrylic signs. The size shall be 250mm x 30mm and letter height shall be 50-70mm for room number, 25-40mm room name letters and braille and tactile characters where applicable. The color and contrast between the text and background shall be high and the color shall be consistent with the veternary clinic branding (if any) or as per the Architect approval. The topography and information shall be Room number: Bold, large font (sans serif preferred), Room function/name: Smaller font beneath the number (e.g., Room 101 – Office) and Braille/tactile lettering placed below the printed text. The signage shall be fixed to the wall at 1.4–1.5 m above floor to centerline of sign on the latch side of the door, or directly on the door if wall space is not available and it shall be fixed with secure concealed fasteners or adhesive (depending on wall/door material). The supplier shall produce and submit Mock-ups for approval before mass production. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect.
3.1 Male & female Rest rooms and with pictogram of gents, ladies and PWD No 4.00 0.00
3.2 First Aid sign as shown in the detail drawing No 4.00 0.00
4 Safety and Compliance Signs
4.1 Design, supply and install Entrance Sign in accordance with this specification and as directed by the Architect. The material shall be made of flame-retardant, impact-resistant ABS clear acrylic plate and shall comply with BS EN ISO 7010 Exit Symbol (E001) and shall have Multi-installation system: Hanging, wall or surface mounted depending on the location. The size of the letter height shall be minimum 150mm with a stroke width 19mm, color contrast to be white letters on green background and the sign shall consist text+ directional arrow that leading to entrance.The sign shall be fixed to entrance access point at 2.00–2.50 m above floor level. The supplier shall produce and submit Mock-ups for approval before mass production or procurement. All signage shall be consistent in size, style, and finish across the project. Final installation shall be subject to inspection and approval by the Architect. No 4.00 0.00
4.2 Supply and fix 3mm rigid PVC/acrylic Fire Extinguisher sign (300mm x 100mm) with 50mm high ISO-compliant white lettering on red background, including all fixings and installation. No 14.00 0.00
4.3 Supply directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. Supply and install directional safety sign with text “TO EMERGENCY ASSEMBLY POINT” and arrow, made of 3 mm thick photo luminescent rigid PVC or acrylic board, minimum size 400 mm × 150 mm, with green background and white lettering/arrow in accordance with ISO 7010 / OSHA standards. Lettering height 50 mm (min.) for legibility. Suitable for indoor/outdoor mounting with weatherproof finish. No 4.00 0.00
4.4 Supply emergency assembly point safety sign complete with standard ISO 7010 pictogram (E007: four people symbol) and text “EMERGENCY ASSEMBLY POINT.” Sign shall be fabricated from 3 mm thick photo luminescent rigid PVC or aluminum composite panel, minimum size 600 mm × 600 mm, with green background and white symbol/text, weatherproof, UV-resistant, suitable for outdoor installation. Fixing accessories included. No 2.00 0.00
4.5 No smoking sign as per the detail Ar.drawing No 28.00 0.00
Total carried to summary USD 0.00
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
Bill No.13-Day Works
1 LABOUR USD 0.00
2 MATERIAL USD 0.00
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
(ALL PROVISIONAL)
In accordance with the Conditions of Contract, the Contractor will be paid day work rates for extra work that cannot properly be measured and valued, and the Contractor is to insert in the space provided below the basic rates and costs of labour,materials and plant as described hereunder:-
1.1 MASON hours 1 0.00
1.2 CARPENTER hours 1 0.00
1.3 SCAFFOLDER hours 1 0.00
1.4 JOINER hours 1 0.00
1.5 PLUMBER hours 1 0.00
1.6 ELECTRICIAN hours 1 0.00
1.7 PLASTERER hours 1 0.00
1.8 PAINTER hours 1 0.00
1.9 LABOURER hours 1 0.00
TOTAL in USD 0.00
1.10 To the basic net rates of labor used for work carried out on day works, an addition 25% percent which is to include for task work and incentive schemes, tools, standing, scaffolding, supervision, insurance, transport profit and overheads.
To collection of Labour Day works 0.00
2.1 Cement Per Tonne 1 0.00
2.3 Aggregate (grade 25 - 5mm) m3 14 0.00
2.4 Steel reinforcement
(i) Mild steel bar Kg 1 0.00
(ii) High tensile bar Kg 1 0.00
2.5 Timber formwork Per SQ.M 1 0.00
2.6 Paint, Gloss Per 4 Litres 1 0.00
2.7 Paint, Emulsion Per 4 Litres 1 0.00
2.8 Mahogany Varnish Per 4 Litres 1 0.00
2.9 100mm diameter uPVC rainwater downpipe 6M Per Each 1 0.00
2.10 Ditto bends Per Each 1 0.00
2.11 Ditto offsets Per Each 1 0.00
2.12 Ditto watershoe Per Each 1 0.00
2.13 Fixing brackets Per Each 1 0.00
2.14 Fixing screws Per Packet 1 0.00
2.15 75mm thick x 375mm wide weather/throated cills Per M 1 0.00
2.16 4 mm Clear sheet glass Per SQ.M. 1 0.00
2.17 100mm long Flush bolt Per Each 1 0.00
2.18 Indicator Signage Per Each 1 0.00
2.19 400mm x 200mm x 100mm hollow concrete blocks Per 1000 1 0.00
2.20 300mm x300mm x 8mm Ceramic floor tiles Per SQ.M. 1 0.00
2.21 150mm x 150mm x 6mm white glazed wall tiles Per SQ.M. 1 0.00
2.22 25mm x 3mm earth copper tape Per M 1 0.00
2.23 35mmsq bare copper cable Per M 1 0.00
2.24 6mmsq bare copper cable Per M 1 0.00
2.25 2.5mmsq. TWE copper cable Per M 1 0.00
2.26 2.5mmsq. SC PVC-I copper cable Per M 1 0.00
2.27 4.0mmsq. SC PVC-I copper cable Per M 1 0.00
2.28 10.0mmsq. 3C PVC-SWA-PVC copper cable Per M 1 0.00
2.29 20mm diameter galvanised steel tubing 6M Per M 1 0.00
2.30 20mm diameter galvanised steel tee Per Each 1 0.00
2.31 20-15mm diameter reducer Per Each 1 0.00
2.32 110mm diameter uPVC soil pipe 6M Per Each 1 0.00
2.33 50mm ditto waste pipe 6M Per Each 1 0.00
2.34 110mm ditto single branch access Per Each 1 0.00
2.35 50mm ditto sweep tee Per Each 1 0.00
2.36 Single bowl, single drainer stainless steel sink size 2000 x 600mm Per Each 1 0.00
To Collection 0.00
2.37 To the basic nett rates of materials used for work carried out on dayworks, an addition of 25% which is to include for unloading and storing as necessary, the use of hand plant, and machinery etc. available on site, profit and overheads.
To collection of Material Day works 0.00
3.1 Portable Compressor with 2 breakers or equivalent with 1500 mm hoses and reels hours 40 0.00
3.2 Damp Truck (0.75 tonne) hours 40 0.00
3.3 Lorry seven tonne tipper hours 40 0.00
3.4 Concrete Mixer (14/10) complete for weight batch mixing hours 40 0.00
3.5 50 mm self priming centrifugal pump with hose and ancillary equipment hours 40 0.00
3.6 Concrete Vibrators hours 40 0.00
To Collection 0.00
3.7 To the basic rates of plant used for work carried out on dayworks, an addition of 25% per cent, which is to include for driver and/or attendance, fuel and consumable stores supervision, insurance, road licence,profit and overheads.
To collection of Plant Day works 0.00
Name of Signatory:
AFR, HORN OF AFRICA MULTI-COUNTRY OFFOCE (HAMCO)
BILLS OF QUANTITIES
MODEL CROP & VEGETABLE MARKET PROJECT
ENHANCING FOOD SECURITY & RESILIENCE OF RURAL COMMUNITIES (EFSR), SUDAN
Bidder Legal Name:
LOTS GRAND SUMMARY Amount in USD
1 Lot 1: Wad Alhilaiw - Kassala State USD
2 Lot 2: East Galabat - Gedaref State USD
3 Lot 3: Toker - Red Sea State USD
GRAND TOTAL ALL LOTS USD 0.00
Name of Signatory:
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
01- Section I - Instructions to Bidders.pdf
Bidding document • 3.47 MB
02- Sections II, III, IV, V - Schedule of Requirements.pdf
Bidding document • 0.95 MB
03- Section VI - Returnable Schedules.docx
Bidding document • 2.92 MB
04.A_ Lot 1 Wad Alhilaiw Model Crops & Vegetables Market.xlsx
Bidding document • 1.20 MB
04.B_ Lot 2 East Galabat Model Crops & Vegetables Market.xlsx
Bidding document • 1.03 MB
04.C_ Lot 3 Toker Model Crops & Vegetables Market.xlsx
Bidding document • 1.03 MB
04.D_ All Lots Grand Summary_Markets.xlsx
Bidding document • 0.04 MB
05.A_ Section IV_ Construction-Contract-for-Small-Works_ Template.pdf
Bidding document • 1.27 MB
05.B_ General Conditions of Contract.pdf
Bidding document • 0.45 MB
06.A_ TECHNICAL SPECIFICATION EFSR MARKET MECHANICAL & PLUMBING.pdf
Bidding document • 0.34 MB
06.B_ Civil Technical Specifications - Market.pdf
Bidding document • 0.79 MB
06.C_ Technical Specification for Electrical Work R3.docx.pdf
Bidding document • 0.31 MB
06.D_ Geotechnical_Soil Investigations and Topographic Survey.pdf
Bidding document • 13.14 MB
07.A_ CROP AND VEGETABLE MARKET STRUCTURAL DRAWING.pdf
Bidding document • 7.22 MB
07.B_ CROP_&VEGITABLE_MARKET_ELECTRICAL_R4.pdf
Bidding document • 16.25 MB
07.C_ CROP AND VEGETABLE MARKET ARCHITECTURAL.pdf
Bidding document • 15.00 MB
07.D_ CROP & VEGETABLE MARKET PLACE MECHANICAL & PLUMBING DRAWINGS.pdf
Bidding document • 6.71 MB
08_ Project Photos.pdf
Bidding document • 0.26 MB
Pre-Bid Meeting Summary.pdf
Bidding document • 0.08 MB
Pre-bid Meeting Presentation -Crops Storages, Crops and Vegetables Markets.pptx
Bidding document • 3.76 MB
Notice on UNGM.html
Notice page • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .