Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
Bid Security (EMD)
Refer Docs
Closing Date
2 Dec 2026, 07:30 (UTC)2 Dec 2026, 1:00 pm IST
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender description: Invitation to Bid (ITB) for the Procurement of Electrical Materials – Kabul, Afghanistan ----- IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
322699
ITB/2026/65465
Invitation to bid
Afghanistan
INVITATION
UTC
21 Nov 2026
16 Nov 2026
AC power cable, 4-core × 50 mm² copper, PVC/PVC, 0.6/1 kV, IEC 60502-1 (packed in rolls of 100 meters)
UV-resistant, heavy-duty nylon cable ties, 300 mm, black, self-locking (Packed in set of 50/100 pcs)
Underground electrical warning tape, 150 mm wide, durable PE with hazard marking (packed in rolls of 50-100 meters)
HDG perforated steel cable tray, 300 × 60 mm, complete with matching accessories
Copper-bonded steel earth rod Ø16 mm × 2.5 m, copper layer ≥250 µm
Bare stranded copper earthing conductor, 10 mm² (packed in rolls of 100 meters)
Compatible corrosion-resistant earthing clamps and connectors
Bare copper earthing / bonding strip, 10 × 3 mm (each pcs to be 3 meter)
Earth inspection pit cover with frame, 300 × 300 mm
Male & Female MC4 Solar Connectors Pair (Packed in set of 10-20 pcs)
IP65 AC Distribution Panel Enclosure: Indoor wall-mounted steel enclosure, 1500 × 1200 × 300 mm, fabricated from 1.5 mm CRCA steel body and 2 mm CRCA steel door, with removable 2 mm gland plate, 2 mm GI mounting plate, RAL 7035 epoxy powder coating, lockable PU-gasketed door, DIN rail provisions, earthing studs and cable-entry arrangements. Supplied empty and unwired, suitable for up to 10 independent inverter circuits, rated 415 V AC, 3-phase, 4-wire, 50 Hz, with provision for a completed assembly rated 25 kA/1 s, in accordance with IEC 61439, IEC 60947 or equivalent standard requirements.
100A, 3-Pole (3P), 400V AC, 50 Hz, inverter-duty rated (System A: 37 kW circuits)
80A, 3-Pole (3P), 400V AC, 50 Hz, inverter-duty rated (System B: 30 kW circuits)
Surge Protection Device (SPD) Type 2 (Class II), 3-Phase + Neutral / PE, 400V AC nominal
dV/dt Output Filter, 100A, 3-Phase, 400V AC, for 37 kW inverter-driven motor output, voltage spike suppression and motor winding protection
dV/dt Output Filter, 80A, 3-Phase, 400V AC, for 30 kW inverter-driven motor output, voltage spike suppression and motor winding protection
Total Price as per (DPU Kabul)
All materials shall be delivered to the WERP Warehouse, PD9 Industrial Park Area, Kabul, on a DPU basis, including unloading. Prices shall include transportation, transit fees, taxes, delivery, and unloading costs, with the supplier bearing all associated costs and risks until delivery at the designated location.
[insert full name of Bidder]
[insert full title]
[insert date]
[insert signature]
[insert name of bidder]
[insert submission date]
Bidder to complete
Details of goods offered (Specify manufacturer & standard)
AC Power Cable, 4-Core × 50 mm², 0.6/1 kV
Four-core stranded copper cable, 50 mm² per core, rated voltage 0.6/1 kV; PVC insulation and PVC sheath.; suitable for fixed AC power installations.
IEC 60228 and IEC 60502-1 compliant with manufacturer type test report for the proposed model including conductor resistance, insulation, voltage withstand, core identification and manufacturer marking.
UV-Resistant Cable Ties, 300 mm
Black, UV-stabilized Nylon 6.6; heavy-duty, self-locking type, Minimum 300 mm length; weather-resistant and suitable for outdoor cable bundling and are in packing of 100 pcs/packing.
Underground Electrical Warning Tape, 150 mm
Durable polyethylene (PE) tape, 150 mm wide, brightly coloured, with permanent electrical-hazard warning text, moisture- and tear-resistant; suitable for underground burial.
HDG Perforated Cable Tray, 300 × 60 mm
Heavy-duty perforated steel cable tray, 300 × 60 mm.
Hot-dip galvanized (HDG) for corrosion protection; supplied complete with matching bends, couplers, supports, brackets and fixing accessories compliance with IEC 61537 or equivalent standard.
Copper-Bonded Steel Earth Rods, Ø16 mm × 2.5 m
High-strength steel core, nominal diameter 16 mm and length 2.5 m.
Corrosion-resistant copper bonding with minimum nominal copper coating thickness 250 µm compliance with IEC 62561-2 or equivalent standard.
Bare Copper Conductor Wire, 10 mm²
High-conductivity stranded bare copper earthing conductor, cross-sectional area 10 mm².
Suitable for earthing and equipotential bonding; compliant with applicable IEC 60228 or equivalent standard.
Earth Clamps and Connectors
Heavy-duty, corrosion-resistant copper alloy, brass or bronze connectors, compatible with the specified earth rods and conductors.
Secure, low-resistance electrical connections; compliant with IEC 62561-1.
Copper Bonding Strip/Tape, 10 × 3 mm
High-conductivity bare copper bonding strip, 10 mm width × 3 mm thickness.
Corrosion-resistant; suitable for earthing and equipotential bonding applications.
Earth Pit Covers, 300 × 300 mm
Heavy-duty earthing inspection pit cover, size 300 × 300 mm, supplied with matching frame.
Weather- and corrosion-resistant; adequate load-bearing capacity; removable access for earthing inspection and maintenance.
MC4 Solar Connectors (Male & Female Pair)
Matching male and female pair of UV-resistant, waterproof solar PV connectors with secure locking mechanism and corrosion-resistant contacts.
Rated minimum 1000 V DC and 30 A; suitable for 4–6 mm² solar cable; IP67 or higher compliant with IEC 62852 or equivalent standard
IP65 AC Electrical Distribution Panel Enclosure – Wall-Mounted
Enclosure and Construction: Heavy-duty, indoor wall-mounted enclosure, dimensions 1500 × 1200 × 300 mm, fabricated from minimum 1.5 mm CRCA steel body and 2 mm CRCA steel door, with removable 2 mm gland plate, internal 2 mm GI mounting plate, and epoxy powder-coated finish (RAL 7035).
Protection and Accessories: Minimum IP65 protection, lockable hinged door with PU gasket, DIN rail provisions, earthing studs, suitable cable entries and mounting accessories. Adequate space for wiring, installation and maintenance of breakers, meters, SPDs and sine-wave/dV/dt filters for up to 10 independent inverter circuits. Supplied empty and unwired.
Electrical Ratings and Compliance: Suitable for 415 V AC, three-phase, four-wire, 50 Hz systems, with provision for a completed assembly rated 25 kA/1 s short-time withstand. Compliant with IEC 60529 (IP65) and suitable for assemblies designed to IEC 61439 and applicable IEC 60947 requirements.
100 A, 3-Pole AC Circuit Breaker
Three-pole, 100 A, 400 V AC, 50 Hz MCB circuit breaker
IEC 60947-2 compliant or equivalent standard, with adequate short-circuit breaking capacity and protection characteristics for the intended installation.
80 A, 3-Pole AC Circuit Breaker
Three-pole, 80 A, 400 V AC, 50 Hz MCB circuit breaker
IEC 60947-2 compliant or equivalent standard, with adequate short-circuit breaking capacity and protection characteristics for the intended installation.
Type 2 AC Surge Protection Device (SPD), 3-Phase + Neutral/PE
Type 2 (Class II) SPD, suitable for a nominal 400 V AC three-phase system with appropriate neutral and protective-earth connections.
Appropriate voltage protection level and surge-discharge capacity; compliant with IEC 61643-11 or equivalent standard.
100 A dV/dt Output Filter
Three-phase dV/dt output filter, minimum 100 A, suitable for a 400 V AC
Designed to reduce PWM voltage rise rate and motor-terminal voltage overshoot, protecting winding insulation as per applicable IEC 61800 series or equivalent standard
Compatible with inverter switching frequency, output current, motor cable length and operating conditions, per applicable IEC 61800 series and manufacturer's specifications.
80 A dV/dt Output Filter
Three-phase dV/dt output filter, minimum 80 A, suitable for a 400 V AC.
Designed to reduce PWM voltage rise rate and motor-terminal voltage overshoot, protecting winding insulation.
Compatible with inverter switching frequency, output current, motor cable length and operating conditions, per applicable IEC 61800 series and manufacturer's specifications.
IP65 Electrical Control Panels – Complete Assemblies (Please refer to the Price Schedule for Items No. 17-35).
Enclosure: Rigid, lockable, corrosion-protected, freestanding metal enclosure with base/plinth, mounting provisions, gland plates, and adequate space for installation, operation and maintenance. Minimum IP65 protection in accordance with IEC 60529, with suitable thermal management maintaining the required protection rating.
Assembly and Construction: Complete, factory-assembled, internally wired, labelled and functionally tested control panel, including all required power/control wiring, terminals, ferrules, lugs, cable glands, protective devices, earthing/bonding and necessary installation accessories.
Power and Control Components: Include all BOQ-specified VFD/inverter input isolators, motor output isolators, changeover switches/contactors, control devices and indicators, suitably rated for the specified inverter outputs and motor duties.
Manufacturer Documentation: Submit panel general arrangement drawings, single-line diagrams, control wiring schematics as per the price schedule description, component schedules and interlocking/operation sequences for approval before manufacturing.
Testing and Quality Assurance: Conduct applicable routine verification, protective continuity checks, wiring and insulation checks appropriate to installed electronic equipment, and functional/interlock testing. Provide panel-specific factory test reports and as-built drawings.
[insert full name of Bidder]
[insert full title]
[insert date]
[insert signature]
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Form E Price Schedule Form for Electrical Material, ITB_2026_65465.xlsx
Bidding document • 0.03 MB
Form F (a) - Technical Bid Form in Excel format .xlsx
Bidding document • 0.04 MB
Form F (b)_ Technical Bid Form in word format .docx
Bidding document • 1.33 MB
ITB_Section I_ Instruction to Bidders - ITB_2026_65465 .pdf
Bidding document • 0.32 MB
ITB_Section II_ Schedule of Requirements -Electrical Material - ITB_2026_65465 .docx
Bidding document • 0.62 MB
ITB_Section III_ Returnable Bidding Forms - ITB_2026_65465 (1).docx
Bidding document • 1.25 MB
ITB_Section IV_ Contract Forms.docx.pdf
Bidding document • 0.47 MB
Notice on UNGM.html
Notice page • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .