Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
237 live and archived tenders were published on this date.
Adding a sidebar filter continues in Live Tenders while preserving this publication date.
237 results • Latest
IIT Palakkad
SUPPLY, INSTALLATION,TESTING AND COMMISSIONING OF 1200 DEGREE CENTIGRADE CHAMBER FURNACE
Haryana Government
Haryana Government
IIT Palakkad
SUPPLY, INSTALLATION,TESTING AND COMMISSIONING OF TEST SETUP FOR HYDRO-MECHANICAL BEHAVIOUR OF REINFORCED SOIL STRUCTURES
Banaras Hindu University
ir Sunderlal Hospital and Trauma Centre BHU, Varanasi
Banaras Hindu University
Sir Sunderlal Hospital and Trauma Centre BHU, Varanasi
Banaras Hindu University
Sir Sunderlal Hospital and Trauma Centre BHU, Varanasi
Banaras Hindu University
Sir Sunderlal Hospital and Trauma Centre BHU, Varanasi
Public Health Engineering Department (PHED)
(2nd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 110 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Garawandkala, Block –Jagdalpur, District – Bastar
Public Health Engineering Department (PHED)
(3rd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 45 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 90 mm dia,110 mm dia UPVC class 6/10 kg/sqcm with suitable joints 80 mm dia, 100 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village -JATAM, Block -JAGDALPUR District – Bastar
Public Health Engineering Department (PHED)
(3rd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 45 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 110 mm dia upvc class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Bhataguda, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(3rd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 100 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - KUMHALI, Block –BASTAR, District – Bastar.
Public Health Engineering Department (PHED)
(2nd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 110 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Kaikagarh, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(3rd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 90 mm dia,110 mm dia & 140 mm dia UPVC class 6/10 kg/sqcm with suitable joints 80 mm dia, 100 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village -KARKAPAL, Block -JAGDALPUR District – Bastar
Public Health Engineering Department (PHED)
(3rd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 60 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia upvc class 6/10 kg/sqcm with suitable joints 80 mm dia & 100 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - BADEMURMA, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(2nd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 110 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Kaikacherbahar, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(3rd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 65 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 140 mm dia UPVC PIPE class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Biranpal, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(3rd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 110 mm dia upvc class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Dhanpunji, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(3rd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 100 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Mangdu Kachora, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(3rd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Deoda, Block –Bastar, District – Bastar.
Public Health Engineering Department (PHED)
(3rd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 55 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia upvc class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Sidmur, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(3rd call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm class 6/10 kg/sqcm with suitable joints 50 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - SIRISGUDA-1, Block –TOKAPAL, District – Bastar.
Public Health Engineering Department (PHED)
(3rd call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 55 KL capacities & staging 12mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia, 100 mm dia, GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - CHINGPAL, Block –DARBHA, District – BASTAR.
Public Health Engineering Department (PHED)
(3rd call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 50 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 100 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - FAFNI, Block –BASTAR, District – Bastar.
Public Health Engineering Department (PHED)
(3rd call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm di & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 110 mm dia & class 6/10 kg/sqcm with suitable joints 80 mm dia & 100 mm dia, GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - HALBAKACHORA, Block -JAGDALPURDistrict – Bastar.
Haryana Government
Madhyanchal Vidyut Vitran Nigam Ltd
Madhyanchal Vidyut Vitran Nigam Ltd
Directorate of Local Bodies UP
Directorate of Local Bodies UP
Public Works Region
Public Works Region
Public Works Region
Public Works Region
Public Works Region
Two year Annual Maintenance for (A)115 Police Officer and 591 Police men Quarter Building(C Type 28 Building ) Snehnagar Nanded AND (B) Police Colony Snehnagar ( 7 Building ) shop building Nanded, Tq.and Dist. Nanded
Public Works Region
Public Works Region
Improvement To MDR 29 Ekdara - Kasarkheda - Kamtha - Kondha - Sheni Road Mdr -26 Km 3/00 To 5/00 Tq. And Dist. Nanded
Municipal Bodies
CIVIL WORK
Municipal Bodies
CIVIL WORK
Municipal Bodies
CIVIL WORK
Municipal Bodies
CIVIL WORK
Municipal Bodies
CIVIL WORK
Municipal Bodies
CIVIL WORK
Municipal Bodies
CIVIL WORK
Municipal Bodies
CIVIL WORKS
Indian Army
Mumbai Metropolitan Region Development Authority (mmrda)
Ministry Of Railways
Across all 237 tenders published on this date. Statuses reflect the latest available updates; check each tender for its current deadline.
A tender can cover more than one state. Group counts may overlap.