Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
5,020 live and archived tenders were published on this date.
Adding a sidebar filter continues in Live Tenders while preserving this publication date.
5,020 results • Latest
Rural Development and Panchayat Raj Department
Rural Development and Panchayat Raj Department
Rural Development and Panchayat Raj Department
Rural Development and Panchayat Raj Department
Rural Development and Panchayat Raj Department
Rural Development and Panchayat Raj Department
Rural Development and Panchayat Raj Department
Rural Development and Panchayat Raj Department
Chandigarh Administration
RDD-CEO-BHANDARA
RDD-CEO-CHANDRAPUR
Bhabha Atomic Research Centre
Fabrication and installation of process piping and equipments and headers and SS 304L Cladding on support structures for RWMF in radioactive area of WMD facilities at BARC, Mumbai.
DG,BSF,MHA
DG,BSF,MHA
PHE
KOLKATA MUNICIPAL CORPORATION
REMOVAL OF SILT FROM DRAINAGE NETWORKS OF JELIA PARA ROAD BYE-LANES NEAR PR. NOS. Z-3/282/4, Z-3/544/2, ETC. IN WARD NO. 141, BR. XV.
Bharat Heavy Electricals Limited
CAP ELEC AL 150MF 20 400V
RDD-CEO-SOLAPUR
A) Construction of Road and Closed Gutter in Maharshinagar at Yashawantnagar B) Const of Closed Gutter in Kirtinagar at Yashwantnagar C) Construction of Road and Closed Gutter in Vijay Colony of Yashwantnagar
DISTRICT HEALTH AND FAMILY WELFARE SAMITY - PASCHIM MEDINIPUR
Public Health Engineering Department (PHED)
(4th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 50 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber &Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - KALIPUR, Block –JAGDALPUR, District BASTAR
Public Health Engineering Department (PHED)
(4th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 70 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber &Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SINGLE VILLAGEof Piped Water Supply Scheme under Jal Jeevan Mission For Village - NARAYANPAL, Block –BASTAR, District BASTAR
Public Health Engineering Department (PHED)
(2nd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber &Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - PARPA, Block –JAGDALPUR, District BASTAR
Public Health Engineering Department (PHED)
(7th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - TOPAR Block –DARBHA, District BASTAR
Public Health Engineering Department (PHED)
(4th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 90 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - POTANAR Block –TOKAPAL, District BASTAR
Public Health Engineering Department (PHED)
(7th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - SATASHPUR Block –LOHANDIGUDA, District BASTAR
Public Health Engineering Department (PHED)
(7th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - GUDRAMARENGA Block –TOKAPAL, District BASTAR
Public Health Engineering Department (PHED)
(7th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - TELANGARAPUR Block –TOKAPAL, District BASTAR
Public Health Engineering Department (PHED)
(7th call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber &Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - NAINNAR, Block –TOKAPAL, District BASTAR
Public Health Engineering Department (PHED)
(7th call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40/40 KL capacities & staging 12/12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under RETRO FITTING of Piped Water Supply Scheme under Jal Jeevan Mission For Village - DARBHA, Block –DARBHA, District BASTAR
Public Health Engineering Department (PHED)
(5th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40/40 KL capacities & staging 12/12 mt., & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under RETRO FITTING of Piped Water Supply Scheme under Jal Jeevan Mission For Village - KOSMI Block –BAKAWAND, District BASTAR
Public Health Engineering Department (PHED)
(7th call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 45 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SINGLE VILLAGEof Piped Water Supply Scheme under Jal Jeevan Mission For Village - KOTAMSAR, Block –DARBHA, District BASTAR
Public Health Engineering Department (PHED)
(5th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40/40 KL capacities & staging 12/12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - KASTURPAL Block –LOHANDIGUDA, District BASTAR
Public Health Engineering Department (PHED)
(7th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 60 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - KALEPAL Block –TOKAPAL, District BASTAR
Public Health Engineering Department (PHED)
Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40KL capacities & staging 12. mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber (02Nos) & Providing, laying, jointing, interconnection, testing and commissioning of mm dia to 63 & 75 mm HDPE PE-100 , PN-6 Pipe 90mm dia UPVC class 6/10 kg/sqcm with suitable joints & 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity Single & Three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe, SS /Nylonwireropeandconnection cable including verification & Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 03 months under Single Village of Piped Water Supply Scheme under Jal Jeevan Mission For Village- Nagaras ,(GP.) Nagaras Block- Sukma,District – Sukma
Public Health Engineering Department (PHED)
Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12. mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber (02 Nos) & Providing, laying, jointing, interconnection, testing and commissioning of mm dia to 63 & 75 mm HDPE PE-100 , PN-6 Pipe & 110 & 90mm dia UPVC class 6/10 kg/sqcm with suitable joints & 80 & 100 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity Single & Three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe, SS /Nylonwireropeandconnection cable including verification of tubewell yield & Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 03 months under Single Village of Piped Water Supply Scheme under Jal Jeevan Mission For Village Kokarpal,(GP)Kokarpal,Block Sukma, District – Sukma
Public Health Engineering Department (PHED)
(5th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under RETRO FITTING of Piped Water Supply Scheme under Jal Jeevan Mission For Village - PANDRIPANI-02 Block –JAGDALPUR, District BASTAR
Public Health Engineering Department (PHED)
(7th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40/40 KL capacities & staging 12/12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - SIRISGUDA-02 Block –TOKAPAL, District BASTAR
Public Health Engineering Department (PHED)
(7th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40/40 KL capacities & staging 12/12 mt., including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - KATAKANDA Block –DARBHA, District BASTAR
Public Health Engineering Department (PHED)
(7th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40/40 KL capacities & staging 12/12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber &Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - SADRA BODENAR Block –BASTANAR, District BASTAR
Public Health Engineering Department (PHED)
(7th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt., including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - MICHNAR-02 Block –LOHANDIGUDA, District BASTAR
Public Health Engineering Department (PHED)
(7th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt., 50 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - KOLENG Block –DARBHA, District BASTAR
Public Health Engineering Department (PHED)
(7th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40/40 KL capacities & staging 12/12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber &Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - PALNAR Block –BASTANAR, District BASTAR
Public Health Engineering Department (PHED)
(7th call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40/40 KL capacities & staging 12/12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber &Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - MATKOT, Block –TOKAPAL, District BASTAR
Public Health Engineering Department (PHED)
(5th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40/40/40 KL capacities & staging 12/12/12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - BADRENGA Block –LOHANDIGUDA, District BASTAR
Public Health Engineering Department (PHED)
Providing, laying, jointing, interconnection, testing and commissioning of mm dia to 63 & 75 mm HDPE PE-100 , PN-6 Pipe with suitable joints 80 & 100 mm dia GI Pipe, valve specials and all fittings including all allied civil works, providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 03 months under Single village of Piped Water Supply Scheme under Jal Jeevan Mission For Village-Nilawaya,Chirmur(GP.) Pordem Block Sukma District – Sukma
Public Health Engineering Department (PHED)
Providing, laying, jointing, interconnection, testing and commissioning of mm dia to 63 & 75 mm HDPE PE-100 , PN-6 Pipe with suitable joints 80 & 100 mm dia GI Pipe, valve specials and all fittings including all allied civil works, providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 03 months under Single village of Piped Water Supply Scheme under Jal Jeevan Mission For Village-Mandimarka,(GP.)Gondpalli Block Konta District – Sukma
Public Health Engineering Department (PHED)
Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40KL capacities & staging 12. mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber (01Nos) & Providing, laying, jointing, interconnection, testing and commissioning of mm dia to 63 & 75 mm HDPE PE-100 , PN-6 Pipe 90mm dia UPVC class 6/10 kg/sqcm with suitable joints & 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity Single & Three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe, SS /Nylonwireropeandconnection cable including verification & Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 03 months under Single Village of Piped Water Supply Scheme under Jal Jeevan Mission For Village- Elkanguda ,(GP.) Kistaram Block- Konta,District – Sukma
Public Health Engineering Department (PHED)
Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40KL capacities & staging 12. mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber (01Nos) & Providing, laying, jointing, interconnection, testing and commissioning of mm dia to 63 & 75 mm HDPE PE-100 , PN-6 Pipe 90mm dia UPVC class 6/10 kg/sqcm with suitable joints & 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity Single & Three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe, SS /Nylonwireropeandconnection cable including verification & Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 03 months under Single Village of Piped Water Supply Scheme under Jal Jeevan Mission For Village- Burkapal ,(GP.) Burkapal Block- Konta,District – Sukma
Public Health Engineering Department (PHED)
Providing, laying, jointing, interconnection, testing and commissioning of mm dia to 63 & 75 mm HDPE PE-100 , PN-6 Pipe with suitable joints 80 & 100 mm dia GI Pipe, valve specials and all fittings including all allied civil works, providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 03 months under Single village of Piped Water Supply Scheme under Jal Jeevan Mission For Village Jatapaad(GP.) Karigundam,Block Konta District – Sukma
Public Health Engineering Department (PHED)
(5th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village - TOYNAR Block –DARBHA, District BASTAR
Across all 5,020 tenders published on this date. Statuses reflect the latest available updates; check each tender for its current deadline.
A tender can cover more than one state. Group counts may overlap.