| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 CrAccepted-AOC | ₹20.3 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹21.8 CrRejected-AOC F 31 INDUSTRIAL AREA PHASE VIII SAS NAGAR MOHALI 160071 | S A S NAGAR | PUNJAB | 160071 | ₹21.8 Cr | L2 | Rejected-AOC NOT BEING LOWEST |
| 3 | L3₹22.0 CrRejected-AOC | ₹22.0 Cr | L3 | Rejected-AOC NOT BEING LOWEST |
| 4 | L4₹28.3 CrRejected-AOC | ₹28.3 Cr | L4 | Rejected-AOC NOT BEING LOWEST |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not admitted for finance bid opening, Bidder Not qualifying PQC Criteria |
Tender Value
₹19.9 Cr
EMD Value
₹15 L
Closing Date
15 Oct 2022, 6:00 pmClosed
Chief Engineer Chennai Zone
Chief Engineer Chennai Zone, Island Grounds, Chennai 600009
PROVISION OF SEWAGE TREATMENT PLANT (STP) INCL REPAIR/ UPGRADATION OF SEWERAGE AND DRAINAGE SYSTEM FOR ARTY CENTER SECUNDERABAD
2022_MES_549865_1
89063/E8
Open Tender
Construction Works
1460 days
Secuderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE Golgonda
₹15 L
Yes
6 Dec 2022
3 Sept 2022
17 Oct 2022
3 Sept 2022
15 Oct 2022
3 Oct 2022
3 Sept 2022 - 24 Sept 2022
Amount
SCHEDULE `A' PART - I is not prepriced by MES
SCHEDULE 'A' PART I - BUILDINGS / STRUCTURES
Designing and constructing STP operator room cum Lab with toilet in single storey (Min Ceiling height 3.20m) with permanent specification having Plinth Area of 30sqm with RCC framed construction using M-25 (Design Mix) in foundation concrete, footings, plinth beam, Columns, lintel, roof beam, roof slab, PCC Solid Block walling, Internal & External plastering, finishing, Roof Treatment, Anti termite treatment, Rolling Shutter, Pressed steel door frame, flush shutter, glazed skelton door shutter, fly proof box type steel window, PVC door, Wall & floor tiles, sanitary fittings & taps in toilets, plinth protection, including necessary excavation in all types of strata, refilling of earth and disposal of surplus earth within 500m lead, all soil waste pipe up to first manhole, etc., complete all as specified in Brief Specification in Particular Specification, at following locations all as specified and as directed :- Location: IB Line Area
Designing and constructing STP Operator room with toilet in single storey (1 No) (Min Ceiling height 3.20m) with permanent specification having Plinth Area of 25sqm each with RCC framed construction using M-25 (Design Mix) in foundation concrete, footings, plinth beam, Columns, lintel, roof beam, roof slab, PCC Solid Block walling, Internal & External plastering, finishing, Roof Treatment, Anti termite treatment, Rolling Shutter, Pressed steel door frame, flush shutter, glazed skelton door shutter, fly proof box type steel window, PVC door, Wall & floor tiles, sanitary fittings & taps in toilets, plinth protection, including necessary excavation in all types of strata, refilling of earth and disposal of surplus earth within 500m lead, all soil waste pipe up to first manhole, etc., complete all as specified in Brief Specification in Particular Specification, at following locations all as specified and as directed :- Locations: a) 6 Bty (O/S Mkd), b) I/S Mkd Lines, c) Taramathi Lines
Designing and constructing of RCC Sumpwell (Lift-well) with Pump Room (clear height 3mtr) over and above the Sumpwell with M-30 design mix foundation concrete, container walls, bottom slab, top RCC roof slab with CI manhole covers, plastering, water proofing, epoxy paint inside, Superstructure of pump room with PCC Solid Block walling, Internal & External plastering, finishing, RCC roof slab, Roof Treatment, Anti termite treatment, Floor tiling, PVC door, Flooring, etc., all as per specifications mentioned in particular specification including necessary excavation in all types of strata, refilling of earth and disposal of surplus earth within 500m lead, all piping connections, valves, MS ladder, suitable window opening with ventilator, BB chambers with 5m of outer wall of tank, etc., including testing for water tightness and hydraulic functioning complete all as shown on drawings, as specified and as directed for the following waste flow capacity, sizes of Sumpwell & location :-
RCC Sumpwell of size 4m Inner dia x 5.5m depth, Avg flow of waste upto 600 Cum/day Location : IBL Area
RCC Sumpwell of size 3.5m Inner dia x 5.0m depth, Avg flow of waste upto 300Cum/day Location :Outside MKD Lines
Designing and constructing of RCC Collection Sumpwell with RCC M-30 design mix foundation concrete, container walls, bottom slab, top RCC roof slab with CI manhole covers, plastering, water proofing, epoxy paint inside, etc., all as per specifications mentioned in particular specification including necessary excavation in all types of strata, refilling of earth and disposal of surplus earth within 500m lead, all piping connections, valves, MS ladder, ventilation shaft, BB chambers with 5m of outer wall of tank, etc., including testing for water tightness and hydraulic functioning, complete all as specified and as directed for the following sizes of Collection Sumpwell and locations :-
RCC Collection Sumpwell of size 4.0m dia x 5.0m depth Location : MKD Lines
RCC Collection Sumpwell of size 4.0m dia x 5.0m depth Location : Lift Well No 1
RCC Collection Sumpwell of size 3.5m dia x 5.0m depth Location : Sig sec
RCC Collection Sumpwell of size 2.5m dia x 5.3m depth Location : Taramathi IRs, JCOs Qtr
GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to IX under Ser No. 5.00 to 12.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the tenderer for SITE CLEARANCE as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for ROADS / FOOT PATH / CULVERTS/ HARD STANDING as listed in Schedule ‘A’ Part- V
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY / TREATED WATER SUPPLY as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for SEWAGE LINE as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for COMPOUND WALL / FENCING/ GATE as listed in Schedule ‘A’ Part- IX
SCHEDULE `A' PART - X TO XIII are not prepriced by MES
SCHEDULE 'A' PART X -STANDBY DG SET
Supply, installation, testing and commissioning of 125 KVA (The capacity of Generator set shall be net after all due derating factors as per relevant lSI standard), silent Diesel engine Generating Set, 415 volts, 3 phase, 0.8 Power factor, 50 Hz, 4 wire system as per IS 10001/10002 comprising of Koel 125 KVA or equivalent, developing suitably derated of Minimum BHP @ 1500 RPM, Liquid Cooled, electric start coupled to alternator as per IS 13364 mounted on a common base frame with standard control panel for automatic starting on main control panel having meters, sound proof canopy, integral fuel tank with battery and leads and accessories complete in all respect with emission control device to control the PM within range as prescribed by NGT/ norms of CPCB and CPCB approved acoustic enclosure suitable for ambient condition at Secunderabad including required PCC foundation as per manufacturers specification and confrrming to conditions under IS 10004722/1460 BS 5514/2613/ 5000 ISO 8526/3046 with following provisions:-
Srl Item No 13.00 (Contd.....) (A) Alternator :- Standard design alternator rated at 125 KV A net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with widing in pole faces, insulating class 'H' and voltage regulation of ± 1 % at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000 and shall be inposition to generate supply with frequency regulation with in ± 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/50001 IS - 4722 and as per the following provisions:- Make:- KIRLOSKAR/JYOTI / STAMFORD/CATERPILLAR
Srl Item No 13.00 (Contd.....) (d) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia as per manufacture standard with MS pipe light grade upto and away two meters height from top of enclosure incluing necessary angle iron frame supports from floor to the bottom of exhaust pipe from the enclosure covered with mineral wool of thickness 50mm rapped with chicken wire mesh of size 2.25mm and aluminium sheet of 24 SWG to be complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type Exhaust manifold Silencer: Residential type Bellows
(C) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch/nozzles/ governer electronic type capable for 1 % speed /frequency regulation. (i) Fuel filters (ii) Fuel hoses (iii) Lub oil System :- (iv)Lubricating oil filter (v) Lubricating oil pump (vi) Air Intake System :- (a) Air intake Manifold (b) Air cleanler dry type (D) Governer :- Electronic Governer (a) Starting System :- Electric Self starter with maintenace free batteries including battery charging alternator. (b) Batteries:- Required capacity and size Battery complete with copper conductor multistrnded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolite all as specified. Make:- EXIDE / AMRON / Produced by original DG set manufacturers (i) Starter gear ring (ii) Start and stop push button (iii) Ignition key / Switch
Srl Item No 13.00 (Contd.....) (iv) Handling and operation: Salient features of accessories shall be as under: (a) Radiator with blower fan (b) Corrosion inhibitor coolant (c) Paper element filters for fuel, lub oil and by pass. (d) Eelctronic governer controlled direct fuel injection system (e) Fly wheel housing and fly wheel.
(E) Generator Monitoring Panel: Comprising of following:- (a) Microprocessor based integrator generator set monitories, metering, protection and control system with built torque matched volts/H3 over load control. (b) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (c) Alternator protection parameters like under voltage, over current, under frequency, over frequency ( alarm & shut down) (d) Relay drivers for remote annuciations (e) Cyclic cranking (f) Auto/manual start stop (g) Alternator trim adjustment from the front key pad (h) Operates within a temperature range 0- 50°C and humidity upto 95% (j) Remote monitoring capabilty through separate interface modules (k) Genset metering parameters like lube oil pressure, coolant temperature, engine speed(rpm), run hours, DC voltage, 3 phase volts and 3 phase amperes, frequency, KW, KVA, power factor (l) Safety Controls : - Engine low lube oil pressure, high water temparature and over speeding of engine. (m) Coupling arrngement : - Flexible coupling, fly wheel to suit flexiable coupling fly wheel housing. (n) Accessories :-A VM Pads built or separtely mounted to manufacturer base frames. (o) Base Frame: - Made out of ISMC 200 of sturdy design made of MS channel with necessary reinforcement and predetermined holes.
(p) Fuel Tank :- Daily service fuel tank of capacity suitable for 12 Hours consumption on full load (Inbuilt) made out of 3mm thick (Heat Retradant) sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity and connected pipe line should be installed with in bulit inside the accoustic enclosure is inclusive of the cost of DG Set and is as per manufacturer design (q) Deliverables:- Confirms the norms established by CPCB.
Srl Item No 13.00 (Contd.....) (F) AMF PANEL:- (a) Auto Main Failure (AMF) panel made out of minimum 2 mm thick CRCA sheet, powder coated of conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase,4 Wire, AC 50 Hz having aluminium bus bar capacity required to carry current at 100% load of DG set with three phase and half neutral colour coded, prewired with copper flexible cable, be all as specified with the following accessories, control cable from Gen set to AMF panel:-
(i) 4 pole contactor of suitable capacty - 2 Nos. (ii) MCCB, 4 Pole as per OEM design -2 Nos (One for Alternator and one for Commercial Supply) with suitable fuse links. (iv) CTs suitable rating for both the supplies. (v) DC Ammeter. (vi) DC Voltmeter. (vii) Push buttons. (viii) Indication Lamps. (ix) 2 over load+ earth leakage relay. (x) Multi functional digital meter for KWH,KVA,KW,Amps,volts, frequency, power factor etc. (xi) SMPS Battery charger 12V, with trickle & Boost charging (xii) On/ Off switch. (xiii) Automatic/manual switch. (xiv) Hooter. (xv) Voltage sensing relay. (xvi) Six window anunciator for fault indications. (xvii) Electro magnetic relays. (xviii) Metering required in DG set :- A, V, Hz, KVA, KW, PF & KWH Metering required in mains :- A, V, Hz.
Srl Item No 13.00 (Contd.....) (G) Acoustic enclosure: CPCB approved enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet steel will provide easy access for maintenance, repairs and operation. The enclosure is custom built to suit conditions, with the following features:-
(a) Custom built product for various equipments, with ensure the optimum performance without duration. (b) Rugged in construction maintenance free and modular designs which facilitate easy at site. (c) 16 SWG (1.6 mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absorption. Acoustic layers are supported by perforated sheets. (d) Sheet metal components of the enclosure should undergo various stages of surfacetreatment prior to painting which leads to be better life of the enclosure against weathering action. (e) Special paint treatment with pure polyester powder/epoxy to be provided for better weather resistance. (f) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently. (g) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used. (h) Working space is to be provided around tbe equipment for easy maintenance / repairs. (j) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per the requirement.
Srl Item No 13.00 (Contd.....) (k) A see through transparent window (glass or acrylic) in front of engine panel to be provided for monitoring the operation. (l) Ducting if required, bellows, mechanical hardware like locks, hinges fasteners etc to be provided. (m) Deliverables. 75 dBA @ imtr at 75% load under free field conditions. The temp inside tee enclosure will be within as per manufacturers recommendations above ambient temp. (n) The enclosure should be provided witb bulk head light fitting for inside illumination (o) The battaries should be placed inside the enclosure beside the DG Set on a suitable inlsulated platform. (p) The DG Set should be provided with external Emergency stop push button. (q) The accoustic enclosure parts shall be of powder coated after pre treatment process. (r) The powder coating shade should be Genset Green. The base frame should be painted with epoxy based black shade. Make for AMF PANEL: DG SET OEM Make for ACCOUSTIC PANEL: DG SET OEM (H) Civil Works :- All civil works with PCC plat form and related to foundations including of panel and equipments and making good the existing structrure of distrubed during installtion and commissioning of Genset. The depth of the foundation shall be minimum 300 mm with antivibration pads or as recommended by the manufacturer.
All as per Item No 13.00 above but of Capcacity 62.5 KVA
All as per Item No 13.00 above but of Capcacity 40 KVA
SCHEDULE 'A' PART XI -SEWAGE TREATMENT PLANTS
All as per Item No. 16.00 above but 400 KLD capacity (300+100 KLD)
All as per Item No. 16.00 above but 300 KLD capacity
All as per Item No. 16.00 above but 200 KLD capacity
Supply,install,testing and commissioning of Non clog vertical submersible pumps with stainless steel housing/body & shaft; cast iron impeller and chrome steel cutter, non-clog to pass 12mm or less size particles, of sufficient Power rating, Minimum flow rate of 350 LPM at 12 mtr head (2 working + 1 stand by), Delivery Size 50mm dia complete all as specified and directed by engr-in-charge. (Location : IBL Liftwell No.2, 6 Bty Liftwell No.2) Note:- One pump should be operated whenever water level reaches more than 0.3 mtr from bottom and both pumps should operate whenever water level reaches below 0.3 m of sewer line. The connected item for this included and shall be measured under relevant items in Electric supply schedule.
M&L for 150 mm dia Ductile iron pipes with spigot and socket end incl titon joints, Class K-9 supplied and laid complete all as directed by Engr in Charge. Note: Excavation & earthwork required shall be measured and paid under Sch 'A' Part VIII (Sewage Disposal).
M&L for 200 mm dia Ductile iron pipes with spigot and socket end incl titon joints, Class K-9 supplied and laid in trenches/walls complete all as directed by Engr in Charge. Note: Excavation & earthwork required shall be measured and paid under Sch 'A' Part VIII (Sewage Disposal).
M&L Construction of RCC pedestal for running of DI line above GL including excavation in trenches in hard/dense soil, PCC 1:4:8, type D2 in foundation , RCC M-25, 10mm thick plastering in CM 1:6, including RFR , removal of surplus soil , white wash painting etc complete all as specified.
SCHEDULE 'A' PART XII - MISCELLANEOUS ITEMS
INTERNAL ELECT SUPPLY
Supply & Fix 20W (1X4') LED Stout plus surface & wall mounted LED fitting, environment friendly energy efficient with electronic driver complete with all fixing arrangement. , Make Havells Cat No.STOUT PLUS600 BS20 WLED 840 SPCWH or Philips Cat-Part No. BN 021C LED20S PSU CDL/NW GR or techno-commercially equivalent model of CG or Wipro
Supply and fix 10W (1X2') LED basic all purpose surface and wall mounting LED baten with polycarbonate housing & integrated electronic driver Light fittings with all attachment & fixing arrangement. Make : Havells Cat No. LUMINE BS10 WLED 865 SPC WH or techno-commercially equivalent model of Philips / Wipro / CG
SEWAGE LINE
Earth work, excavation in any kind of soils by mechanical means (Hydraulic excavator) in foundation trenches or drains (n.exc.1.5m in width or 10sqm on plan) including dressing of sides and ramming of bottoms, exc.1.5m but n.exc.3.0m in depth including getting out the excavated soil and disposal of excavated soil as directed, within a lead of 50m, etc., complete all as specified and as directed.
Earth work, excavation in ordinary rocks by mechanical means (Hydraulic excavator) in foundation trenches or drains (n.exc.1.5m in width or 10sqm on plan) including dressing of sides and ramming of bottoms, exc.1.5m but n.exc.3.0m in depth including getting out the excavated soil and disposal of excavated soil as directed, within a lead of 50m, etc., complete all as specified and as directed.
Earth work, excavation in Hard rock where blasting is probihited by mechanical means (Hydraulic excavator) in foundation trenches or drains (n.exc.1.5m in width or 10sqm on plan) including dressing of sides and ramming of bottoms, exc.1.5m but n.exc.3.0m in depth including getting out the excavated soil and disposal of excavated soil as directed, within a lead of 50m, etc., complete all as specified and as directed
M&L for laying DWC sewage pipe 150mm bore including sealing joint, fittings etc with collar complete all as specified and directed. Note: DWC pipe shall be of minimum 12 m length.
M&L for laying DWC sewage pipe 300mm bore including sealing joint, fittings etc with collar complete all as specified and directed. Note: DWC pipe shall be of minimum 12 m length.
EXTERNAL ELECTRIC SUPPLY
Transformer LT Panel for IB Line STP Supply, Installation, testing and commissioning of LT feeder pillar box, factory made, CPRI approved, outdoor type floor mounting with channel iron pedestal frame made out of 3 mm thick CRCA sheet steel for outer body and 2 mm thick for inner partition, compartmental type, dust proof, free standing, suitable for working on440 volts 3 phase 50 Hz A C supply, vermin proof, front and rear opening, hinged doors etc powder coated as per seven tank process and IP 65 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm , 3 phase and neutral copper bus bar suitable capacity with non adhesive color coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts bolts and washers, copper strips of suitable size for connecting MCCB, Digital Voltmeter, digital ammeter with suitable rated CTs, LED phase indication lamps & PCC works complete all as specified and directed with the following switch gears:- (a) MCCB FP 200A 35KA -01 No (Incoming) (b) MCCB FP 160A 35 KA - 1 No (out going ) (c) MCCB FP 63 Amps 25 KA - 1 Nos as spare for Future load on Trasnformer) (d) Provn for MCCB FP 32 Amps, 25 KA- 01 No for Future load Note : (1) The rate quoted shall be deemed to be included for all out going/incoming cable connection marking including digging out loop, writing of feeder names with white paint in capital letters, suitable size of glands & lugs to be provided for cable, etc complete. (2) Design / drawing / BOM of the Panel board showing the dimensions is to be obtained from OEM / Auth Supplier & is to be got approved from the GE & Engr-In-Charge before placing final order to the manufacturer.
IB Line Area STP Load Distribution Panel All as per Item No 32.00 above but comprising of the following switch gears:- (a) MCCB FP 160Amps 35 KA - 1 No (Incoming). (b) MCCB FP 125 Amps 35 KA - 2 Nos (For STP & Spare). (c) MCCB FP 32 Amps 25 KA - 04 Nos (02 Nos for treated water pumps, 01 No for Lift well & 01 N0 for spare) (d) MCB SPN - 32 Amps - 01 No (e) Street light timer (Astra type) with contactor & MCB, TPN 16A- 01 Set (f) Manually operated Capacitor bank of 30 KVAR( 2 x 2 KVAr + 2 x 3 KVAr+ 2 x 5 KVAr+ 10 x 1 KVAr) with MCCB - 01 Set (g) 10 HP Centrifugal pump starter including preventor, contactors,relays complete - 2 Sets (h) Digital multy function meter - 01 No
MKD Line Area STP Load Distribution Panel All as per Item No 32.00 above but comprising of the following switch gears:- (a) MCCB FP 160 Amps 35 KA - 01 No (Incoming). (b) MCCB FP 100 Amps 25 KA - 02 Nos (For STP & Spare). (c) MCCB FP 32 Amps 25 KA -03 Nos. (02 Nos for treated water pumps & 01 No for spare) (d) MCB SPN - 32 Amps - 01 No (e) Street light timer (Astra type) with contactor & MCB, TPN 16A- 01 Set (f) Manually operated Capacitor bank of 20 KVAR ( 1 x 2 KVAr + 1 x 3 KVAr+ 3 x 5 KVAr+ 10 x 1 KVAr) with MCCB - 01 Set (g) 7.5 HP Centrifugal pump starter including preventor, contactors,relays complete - 2 Nos (h) Digital multy function meter - 01 No
Transformer LT Panel for 6 Bty AREA (O/S MKD LINE) STP All as per Item No 32.00 above but comprising of the following switch gears:- (a) MCCB FP 160 Amps 35 KA - 01 No (Incoming). (b) MCCB FP 100 Amps 25 KA - 01 Nos (out going) (c) MCCB FP 63 Amps 25 KA - 01 Nos (Spare) (d) Provn for MCCB FP 32 Ammps, 25 KA- 01 No for Future load
6 Bty AREA (O/S MKD LINE) STP Load Distribution Panel All as per Item No 32.00 above but comprising of the following switch gears:- (a) MCCB FP 100 Amps 25 KA - 01 No (Incoming). (b) MCCB FP 63 Amps 25 KA - 02 Nos (For STP & Spare). (c) MCCB FP 32 Amps 25 KA - 04 Nos (02 Nos for treated water pumps, 01 No for Lift well & 01 N0 for spare) (d) MCB SPN - 32 Amps - 01 No (e) Street light timer (Astra type) with contactor & MCB, TPN 16A- 01 Set (f) Manually operated Capacitor bank of 15 KVAR (1 x 2 KVAr + 1 x 3 KVAr+ 2 x 5 KVAr) with MCCB - 01 Set (g) 7.5 HP Centrifugal pump starter including preventor, contactors,relays complete - 2 Sets (h) Digital multi function meter - 01 No
TARAMATHI JCO/ORs STP Load Distribution Panel All as per Item No 32.00 above but comprising of the following switch gears:- (a) MCCB FP 63 Amps 25 KA - 01 No (Incoming). (b) MCCB FP 40 Amps 25 KA - 02 Nos (For STP & Spare). (c) MCCB FP 32 Amps 25 KA - 03 Nos. (02 Nos for treated water pumps & 01 No for spare) (d) MCB SPN - 32 Amps - 01 No (e) Street light timer (Astra type) with contactor & MCB, TPN 16A- 01 Set (f) Manually operated Capacitor bank of 10 KVAR (1 x 2 KVAr + 1 x 3 KVAr+ 1 x 5 KVAr) with MCCB - 01 set (g) 5.0 HP Centrifugal pump starter including preventor, contactors,relays complete - 2 Sets (h) Digital multi function meter - 01 No
Intermediate Lift Well LT Panel All as per Item No 32.00 above but comprising of the following switch gears:- (a) MCCB FP 32 Amps 25 KA - 01 No (Incoming). (b) MCCB FP 20 Amps 25 KA - 03 Nos (out going). (c) DOL Starter consisting of Suitable contactors,relays,Single phase preventor- 03 Nos (d) MCB SPN - 32 Amps - 01 No (e) Ultrasonic liquid level transmitter for controlling three nos of pumps for auto operation based on liquid level of sump/tank with the following specifications: (i) Type : Ultrasonic (Sound wave) (ii) Measuring range : 0.4 - 6 mtr (iii) Power supply : 16-30 V DC (iv) Output : 4-20 mA (v) Accuracy : ±0.5% of FSD (vi) Maximum temperature : -40 to 70C (vii) Maximum pressure : < 1 bar (viii) Accessories : Mounting bracket & FRP canopy
Supply and fix pole mounted SMC box weather proof type with hinged type doorof white colour of size 250x200x100 with 4 way PVC connector including 1 No MCB SP 6 amps and with suitable clamping arrangements for street light fittings all as specified and directed by Engr-in-charge.
Supply and fix cable route indicator made out of round CI disc embosed LT/HT cable, of size 16cm dia , 6mm thick duly revited with angle of size 50x50x4mm and 60cm long incuding PCC 1:2:4 type B2 using 20mm graded stone aggreate, 15cmx15cmx15cm for grouting the same all as specified and as directed
Construction of Transformer foundation of size 1.80x1.50x1.50Mtr (above GL) and 2.20x1.90x1.0 Mtr (below GL) inlcuding excavation in trenches in hard/dense soil, PCC 1:4:8 type D2 bed concrete , RR stone masonry in CM 1:6 for foundation, plastering in CM 1:4, 20mm thick including PCC coping and RFR , removal of surplus soil and three coats white wash etc complete all as specified and directed.
EXTERNAL WATER SUPPLY/TREATED WATER SUPPLY
M & L for construction of valve chamber 90x90x90 cm inner dimensions, brick masonry in cm 1:4 PCC base in 1:3:6 of 7.5 cm thick & plastering 15 cm thick in CM 1:4 in inner side/ coping of all chamber, fabrication of Iron frame 40x40x6 mm size with angle iron, MS cover 3 mm thick with hinges and locking arrangements, painting of steel surfaces with one coat of zinc chrome primer and two coats of epoxy paint including necessary earth work, returning and refilling etc all as specified and as directed.
M & L for construction of valve chamber 60x60x60 cm inner dimensions, brick masonry in cm 1:4 PCC base in 1:3:6 of 7.5 cm thick & plastering 15 cm thick in CM 1:4 in inner side/ coping of all chamber fabrication of Iron frame 40x40x6 mm size angle iron MS cover 3 mm thick with hinges and locking arrangements painting of steel surfaces with one coat of zinc chrome primer and two coats of epoxy paint including necessary earth work, returning and refilling etc all as specified and as directed.
Supply, installation, testing and commissioning of Mono block motor pump set complete operating on 3 phase 415 volt 50 Hz of electrically driven of capacity 18 mtrs head 1250 LPM mechanical seal, CI casing & impeller, SS shaft, each pump should be complete with suitable size suction and delivery pipe line up to 10m, foot valve, butterfly valve, NRV and PVC Copper cable from starter to Pump motor, HP/LP Pressure switch for common header and Ultrasonic level switch for automatic operation interconnecting cable for (1 W+ 1 S), required foundation with weather protecting FRP canopy, complete in all respect as directed and as per OEM recommendations. Location: IBL Area
Supply, installation, testing and commissioning of Mono block motor pump set complete operating on 3 phase 415 volt 50 Hz of electrically driven of capacity 20 mtrs head 800 LPM mechanical seal, CI casing & impeller, SS shaft, each pump should be complete with suitable size suction and delivery pipe line up to 10m, foot valve, butterfly valve NRV and PVC Copper cable from starter to Pump motor, HP/LP Pressure switch for common header and Ultrasonic level switch for automatic operation interconnecting cable for (1 W+ 1 S), required foundation with weather protecting FRP canopy, complete in all respect as directed and as per OEM recommendations. Location:- MKD Area
Supply, installation, testing and commissioning of Mono block motor pump set complete operating on 3 phase 415 volt 50 Hz of electrically driven of capacity 20 mtrs head 625 LPM mechanical seal, CI casing & impeller, SS shaft, each pump should be complete with suitable size suction and delivery pipe line up to 10m, foot valve, butterfly valve NRV and PVC Copper cable from starter to Pump motor, HP/LP Pressure switch for common header and Ultrasonic level switch for automatic operation interconnecting cable for (1 W+ 1 S), required foundation with weather protecting FRP canopy, complete in all respect as directed and as per OEM recommendations. Location:- Outside MKD Area
Supply, installation, testing and commissioning of Mono block motor pump set complete operating on 3 phase 415 volt 50 Hz of electrically driven of capacity 20 mtrs head 420 LPM mechanical seal, CI casing & impeller, SS shaft, each pump should be complete with suitable size suction and delivery pipe line up to 10m, foot valve, butterfly valve NRV and PVC Copper cable from starter to Pump motor, HP/LP Pressure switch for common header and Ultrasonic level switch for automatic operation interconnecting cable for (1 W+ 1 S), required foundation with weather protecting FRP canopy, complete in all respect as directed and as per OEM recommendations. Location:- Taramathi Area
Supply and fixing of full circle metal impact sprinkler, corrosion proof I beam construction for added strength, stainless steel spindle, fulcrum pin and spring well balanced gun metal swing arm to ensure smooth and uniform rotation, brass nozzles with hydro dynamically designed inner profile for precise jet and longer radius of throw 360 degree angle view complete set
Supply and fix Cast Iron Air Valves with single air Outlets and flanged ends conforming to IS 14845 of size 50 mm dia bore including fixing in DI ipe line of dia 100mm complete all as directed and specififed by engr-in-charge.
M&L for earthing of machinery /equipment Installed at power house /substation complete using galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 32x 6 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board /switch board /control board all as shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete. Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 6 mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI Wire length up to 7.50M will be measured as one unit)
SCHEDULE 'A' PART XIII (MANNING AND OPERATION OF STP DURING DEFECTS LIABILITY PERIOD)
Manning and operation of 04 Nos of Sewage Treatment Plant round the clock in 3 shift of 8 hours each, including all Sundays and holidays by employing 01 No ITI qualified operator per shift for operation of each plant consisting of Pumps/motors in Liftwell/sewage pumping station, Collection sump, Bar screen chambers,Equalisation pumps, MBBR fluidized bio-media with Air blower, chemical dosing pumps, Sludge dewatering mechanism/pumps and Dual media filters and connected accessories upto and including pumping out the treated water collected in the sump with and including consumables required for smooth running of STP. Carrying out daily, weekly, monthly, quarterly & half yearly maintenance etc., complete for First year during defects liability period (i.e after handing over of STP after physical completion of Phase I subjected to 'Nil' Defects) all as specified and as directed
Manning and operation of 04 Nos of Sewage Treatment Plant round the clock in 3 shift of 8 hours each, including all Sundays and holidays by employing 01 No ITI qualified operator per shift for operation of each plant consisting of Pumps/motors in Liftwell/sewage pumping station, Collection sump, Bar screen chambers,Equalisation pumps, MBBR fluidized bio-media with Air blower, chemical dosing pumps, Sludge dewatering mechanism/pumps and Dual media filters and connected accessories upto and including pumping out the treated water collected in the sump with and including consumables required for smooth running of STP. Carrying out daily, weekly, monthly, quarterly & half yearly maintenance etc., complete for Remaining period of First year and Second year during defect liability period after completion of 11 months of handing over of STP after physical completion of Phase I all as specified and as directed
Manning and operation of 04 Nos of Sewage Treatment Plant round the clock in 3 shift of 8 hours each, including all Sundays and holidays by employing 01 No ITI qualified operator per shift for operation of each plant consisting of Pumps/motors in Liftwell/sewage pumping station, Collection sump, Bar screen chambers,Equalisation pumps, MBBR fluidized bio-media with Air blower, chemical dosing pumps, Sludge dewatering mechanism/pumps and Dual media filters and connected accessories upto and including pumping out the treated water collected in the sump with and including consumables required for smooth running of STP. Carrying out daily, weekly, monthly, quarterly & half yearly maintenance etc., complete for remaining period of second year during defects liability period after completion of 22 months of handing over of STP after physical completion of Phase I all as specified and as directed
f) Proper and effeicient functioning of the plant must be ensured through regular inspection by qualified Engineer bi-monthly preferably by OEM or by his authorised agency. g) The contractor shall carry out routine maintenance as per procedure mentioned in the PS. h) Staff deployed by the contractor shall carry out daily careful cleaning of the inside installation, greasing of pump, motors, panel boards, DG sets and internal portion of pump house building , 3m external portion , 3m in radius for outdoor panel boards and maintain installations in presentable condition all time all as specified and as directed. j) The contractor shall carryout routine check and maintain check sheet daily, weekly, monthly and upkeep the installation , rectify normal trouble shooting, replacement of gland packing of pumps and sluice valves in installations and minor parts like nuts, bolts, washers, coupling rubber, star packing etc. without extra cost to the deparment. k) Contractor will maintain log sheet daily and submit to department duly completed along with attendance sheet and payment register. l) No T & P will be issued by the department for doing the above work, it shall be arranged and provided by the contractor like PH testing kit, chlorine test kit, turbidity test kit, pipe wrench, screw drivers, sluice valve opening /closing kit, cutting plier, digging tools etc. m) The contractor shall check and implement all the labour laws/precautions for health and safety of labour /OEM operator working in hygenic conditions. p) The rates quoted by the contractor shall be inclusive of proper uniform of technician/operator as directed by GE.
Hydrotech Paryavaran India Pvt. Ltd.
C R R CONSTRUCTIONS
Indus Projects Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid