Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC G 5 2 1 PANCHADEEP CO OP HSG SOCIETY SECTOR 29 VASHI NAVI MUMBAI 400 703 | THANE | MAHARASHTRA | 400703 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹40.6 L+₹1.3 L (3.36%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹41.0 L+₹1.7 L (4.33%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹42.2 L+₹2.9 L (7.32%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹42.6 L+₹3.3 L (8.46%)Rejected-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
23 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) MANKHURD
GE (NW) MANKHURD, MUMBAI-400 088
PROVISION OF ESCAPE LADDER IN HIGH RISE BUILDING P-43 AT INS TANAJI AND PROVISION OF LPG STORE ROOM AT INS TANAJI UNDER GE (NW) MANKHURD
2021_MES_483589_1
8112/E8
Open Tender
Civil Works
Item Rate
210 days
GE (NW) MANKHURD
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (NW) MANKHURD
₹79,000
Yes
14 Dec 2021
23 Oct 2021
25 Nov 2021
23 Oct 2021
23 Nov 2021
10 Nov 2021
23 Oct 2021 - 5 Nov 2021
60 days
Amount
Surface dressing n.exc 15cm deep and getting out in soft and loose soil etc complete all as specified and directed.
Excavation in overareas,exc 1.5m wide foundation etc and getting out in hard /dense soil any type of soil etc complete all as specified and directed.
Excavation in overareas,exc 1.5m wide and n exc 3.0m foundation etc and getting out in hard /dense soil any type of soil etc complete all as specified and directed.
Excavation in trenches,n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc and getting out in hard /dense soil any type of soil complete all as specified and directed.
Excavation in trenches not exc 1.5 metre wide and not exc 1.50 mtr depth for laying of underground cable, erection of poles etc. and getting out in soft/loose soil complete all as specified and directed.
M&L for PCC 1:2:4 type B2 (using 20mm graded aggregate) as in surface channels and drains etc complete all as specified and directed.
M&L for broken stone boulder of size exc 63mm but not exc 100mm hand packing at a back of walls over arches etc .and raising (or lowering) to the required height/depth in layers not exc. 15cm thick, watered and rammed etc complete all as specified and directed.
M&L Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete and surrounding posts etc complete all as specified and directed.
M&L for cement concrete type B2 1:2:4 (using 40mm graded aggregate) posts (including caps and bases) bed blocks, retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars etc complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and directed.
Add or deduct for each 25 mm girth or part thereof over or under 30 cm ditto etc complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20mm graded agg as in coping etc complete all as specified and directed.
M&L for factory made precast Cement Concrete (1:2:4) type B-0, using 12.50mm graded stone aggregate making rounded or chamfered on edges as required fixed in position as in kerb stone using cement mortar 1:4 including demolition of PCC,excavation and earthwork and ramming etc complete all as specified and directed.
M&L for reinforced cement concrete M30 Design mix (20mm graded aggregates) for foundation and plinth beams etc complete all as specified and directed.
M&L for reinforced cement concrete (Design mix) in M-30 (using 20 mm graded aggregates) in columns/pillars/post/struts complete all as specified and directed.
M&L for reinforced cement concrete (Design mix) in M-30 (using 20mm graded aggregate) for beams, lintels over 1.5m span complete all as specified and directed.
M&L for reinforced cement concrete (Design mix) in M-30 (using 20 mm graded aggregate) for slabs suspended on walls, beams and columns, in floors, roofs, landings cupboard slabs and in shelves and the like etc complete all as specified and directed.
M&L for reinforced cement concrete type (design mix) M-30 (using 20 mm graded stone aggregate) in chajjas and the like complete all as specified and directed. Note of item No 14 to 18 : Design mix shall be carried out from approved lab such as IIT/ NIT/ SEMT Pune or any NABL approved lab.
M & L for formwork to sides of concrete foundations and plinth beams and similar work vertical or to batter for flat and fair finished surfaces etc complete all as specified and directed.
Use & waste of formwork to rough finished surface of concrete of side of pillars, posts, struts, piers, columns and stanchions for square, rectangular fair finished surfaces etc complete all as specified and directed.
Use & waste of formwork to edge of conceret flat,treat break in floors,window cills, concrete railling, opening in conceret wall ,floor and roof n.exc 20cm wide and side of RCC bands in walls, horizontal or sloping and similar work exc 10 cm and n exc 20 cm wide fair finished surfaces. and complete all as specified and directed
Use & waste of formwork to side and soffits of rough finished surface of concrete of floor or roof beams and lintels, cantilevers,overhanging etc.fair finished surfaces complete all as specified and directed.
Use & waste of formwork to fair finished flat soffits of suspended slabs such as roof slabs, floor slabs and similar work not exc 200 mm thick complete all as specified and directed.
Use & waste of formwork to fair finished flat surface to chajjas, water troughs and similar items including edges complete all as specified and directed.
M&L for TMT steel bars 10mm dia and over, cut ot lenth,bent to shape required,including cranking bending spirally for hooping for columns,hooping ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.
All as per Item No 25.00 above but 5mm dia and over upto including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed.
Returning filling in with approved earth obtained from excavation after removal of grass, vegetation etc. including spreading, levelling, watering & well ramming in layers n exc 25 cm thick in each layers, etc complete all as specified and directed.
Removing and disposing off the excavated material/soil out side MD Land, etc complete all as specified and directed. Note : For payment purposes, quantity of excavation after deduction of the quantity of returning filling, shall only be payable under this item.
S&F rolled section as in Plate girder or single stanchions, built up of one beam of channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections plates. Gusset plates, wind ties, fastening, nuts, bolts etc, conforming to Fe 410-W(E-250 grade quality 'B'), etc complete all as specified and directed.
M&L Stairs (framed) including stringers, treads, landing, balusters, hand rails etc, including cleats, brackets, etc witih ms Angle flat etc confirming to Fe- 410 Gde E. etc complete all as specified and directed. Note : Necessary design for stair case to be approved by GE. The MS angle/truss shall be provided as per the drawings subject to final approval/modification as approved by the GE
S&F Plates (chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc complete all as specified and directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 gde E etc complete all as specified and directed.
S & F Rolled Mild Steel Framed work as in doors or Gates of angle or other section confirming to Fe 410 - S, with gusset plates, rails braces, etc, complete, drilled for fixing of steel sheeting or other covering and hanging and fixing etc complete all as specified and directed.
S & F Framed work as grills, gratings etc, with ends of bars, shouldered and/or riveted, or forget into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, framework of water tanks and similar work confirming to Fe-410-0 or Fe-310-0 etc complete all as specified and directed.
M&L Cutting openings, through brick walls for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc, to store and rubbish not exc. 50m etc complete all as specified and directed.
M & L for brick work in CM (1:6) using sub class 'B' bricks strainght or or curved as curved as required on plan exc 6mtrs mean radius etc complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of bricks or concrete surface work in CM 1:6, finished the surfaces even & smooth with sagol finish etc complete all as specified and directed.
M&L for rendering 20 mm thick ( 15+5 mm )on fair faces of bricks or concrete surface work in CM 1:4, finished inculiding with integral water proofing compound 3% for 5mm thick plaster by weight of cement finished fair and even including necessary scaffolding up to 24 m height as sand faced finish etc complete all as specified and directed. Note : WPC shall be measured and paid separately .
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaceincluding necessary scaffoldings etc, complete all as specified and directed.
M&L for preparing new plastered surface of walls, and applying two coat of Distemper oil emulsion over a coat of putty 3mm thick etc complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed.
Demolition of brick work and/ or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc and including removing rubbish outside MoD land complete all as specified and directed. Note: Masonary work above ground level shall be measured and paid for under this item.
M&L for PCC block masonry with solid blocks type C1 1:3:6(using 20mm graded aggregate) exc 10 cm in width and setting in cement mortar 1:6 etc complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection 75mm thick, with expansion joints & top surface finished even and smooth without using extra cement etc complete all as specified and directed.
M&L 200 mm thick Cement concrete type B-1, 1:2:4 (using 40 mm graded aggregate) of flooring finishing cement concrete surface even and smooth using extra cement complete all as specified and as directed
M&L 75 mm thick Cement concrete type D2, 1:4:8 (using 40 mm graded aggregate) as in sub base of flooring complete all as specified and as directed
M&L Machine pressed precast concrete interlocking paver block Coloured any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over and including 25 mm thick sand cushion etc complete all as specified and directed.
M & L two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of previously untreated surfaces of steel and iron exc 10 cm width or girth etc complete all as specified and directed.
Demolition of concrete of any description and in any thickness (reinforcement) below or above ground level. etc complete all as specified and directed.
M&L for Ready mix plaster 15mm thick on fair faces of bricks or concrete surface including necessary scaffolding upto 24m height etc complete all as specified and directed.
M&L for 8 mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing surfaces even and smooth complete all as specified and directed Make: Easy Plast from M/s wall plast or chemplast or readyplast from Ultratech” Note: (i) The thickness of plaster specified above is the minimum thickness and the quoted rates shall also be deemed to include for provision of dubbing of the surfaces with ready mix plaster and nothing extra shall be payable on this account. (ii) This item shall be operated only for the locations where the thickness of existing adjoining plaster is to be matched
M& L for 3mm thick wall care putty on ceiling surface finished even & smooth etc complete all as specified and directed.
M&L for preparation of newly plastered surfaces of celings and applying three coats of white wash etc complete all as specified and directed.
M&L pre polished Machine cut kota stone slab flooring20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over screed bed or bedding layer of morar 20 mm in cement mortar 1:6 etc complete all as specified and directed.
M&L pre polished Machine cut kota stone slab 20-25mm thick in riser of steps, thread, skirting, dado over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over screed bed or bedding layer of morar 20 mm in cement mortar 1:6 etc complete all as specified and directed.
Material and labour for screed bed 15 mm thick on brick work or concrete surfaces finished even and fair in cement plaster 1:4, complete all as specified and as directed with mixing water proofing compound.Note:( wpc shall be measured and paid separately)
Supply only water proofing compound powder etc complete all as specified and directed.
M & L for preparation of existing surface by cleaning, removing of loose material and filling cracks with polymer modified mortar using Epoxy mortar, and applying Smartcare PU Magnum or equivalent is a polyurethane elastomeric waterproofing liquid membrane which offer superior mechincal, chemical, thermal, UV & weather resistant properties,as it is based on pure, elastomeric , hydrophobioc polyurethane coatings at a coverage of 1.6kg per sqmt in 2 coats, of make - ASIAN/ SIKA/ STP/FOSROC or equivalent
M&L Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members Wt of Jali Exc 4.0 kg/sqm
Supply and Installation & stamping on the freshly laid new concrete including finishing & coloring the top surface accurately to the required level, shape and size (min 4mm thk.) using approved colour shade Colour Hardener and Powder Release Agent and stamping it using approved stamp pattern and antiquing it on top with approved colour using Antiquing Agent Sealing the entire area of stamped concrete using Concrete Sealer. Including staining the extra and above the stamping surface with Acid/Dye/Enviro stain before application of sealer,including formwork with M.S. angle and compaction of concrete etc complete as directed by GE
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6, as in wall etc complete all as specified & directed. Note: PCC bond stone and face work shall be measured and paid separately.
Extra over stone walling for hammer dressing to face stones with maximum depression on fair face from straight edge held against the dressed surface not exceeding 40 mm for granite or trap stone of face beds & joints as specified of random rubble walling uncoursed or brought upto course complete all as specified and directed.
M& L for raised pointing to random rubble masonry uncoursed or brought upto courses in CM 1:6 , complete all as specified & directed.
Supply and fix LED running man sign board IP Class : IP20 of 1.5 watt suitable for wall and mounting, Input Voltage 120 - 347 VAC, 60 Hz with Nickel Cadmium Battery of Backup time 90 min at operating Temperature 0'C - 40'C complete all as specified and directed.
Supply and fix Emergency exit light with SMD LED with 90 minutes backup time with battery. ABS/MS fire retardant body, overcharge and overdischarge protection, test switch and charge indicator. Wide input voltage 120 to 340 Vac. Operating temperature 0-40 Deg C Matrix,Prolite, Technoware, Mircom, etc complete all as specified and directed.
M&L for circuit wiring using proper colour coding with three run of single core PVC insulated, FRLS (one run of 1.5 sqmm for earth wire), unsheathed suitable for 1100 volts multistranded copper conductor cable of size 1.5 sqmm drawn in and including PVC casing caping medium grade of suitable size ISI marked fixed in wall / roof etc with required acessories etc complete all as specified and directed.
M&L for circuit wiring using proper colour coding with three run of single core PVC insulated, FRLS (one run of 1.5 sqmm for earth wire), unsheathed suitable for 1100 volts multistranded copper conductor cable of size 1.5 sqmm drawn in and including PVC conduit pipe medium grade of suitable size ISI marked fixed in wall / roof etc with required acessories complete all as specified and directed.
S & F ceiling rose surface bakelite, 65x50mm, three terminals with ISI mark etc complete all as specified and directed.
S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for LED fitting etc complete all as specified and directed.
S&F aluminium earth strip as roof/down/earth contunity conductors of size 25x3mm with saddles, insulators, GI screws, etc to / at any position / location of sheds complete all as specified and directed
Supply and fix GI strip 32mm x 6mm buried in ground complete all as specified and directed by the Engineer-in-charge
M&L for Earth test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mmm drilled and screwed including 3 nos 8mm dia, 25 mm long hex head screw complete all as specified and directed by the Engineer-in-charge
S&F air termination, single pointed aluminium rod, 12mm dia 300mm long at any position / location including all necessary scaffolding / staging required, etc. complete all as specified and directed by the Engineer-in-charge
M&L for pre-cast cement concreate block of size 0.25M x0.25M x0.15M for fixing of Aluminium strip type C1 1:3:6 using 20mm graded stone aggregate in cement motor 1:4, including fixing the concrete block on terrace for fixing of lightning conductor complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.0 sq mm 4.0 core complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified.
M & L for sand cushioning by spreading in trenches fine dry river sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
Supply install, test and commissioning of Powder coated LT Feeder panel cubical out door type Channel mounted compartmentalized in construction all Confirming to IS 8623 Part 1 1993 CPRI approved factory fabricated made out of 3 mm thick CRCA sheet & suitable size of make as per CA to accomodate all accessories / fittings, to accommodate incoming MCB and TPN Copper bus bars, incomer MCB and outgoing MCB, Contactors The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCB. The connecction between Bus Bar & MCB should be done by copper bus bar link. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 40mm X 40mm X 6mm but of A detachable predrilled gland plate of thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front openable lockable /openable by key from both side. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including, control wiring by 1.5 Sqmm Wire and consisting the following, including PCC foundation, excevation, grouting bolts a) Copper Bus bar 100 Amp b) MCCB FP 40 Amps- 01 Nos(incomer) c) MCB TPN 40 Amps-02 Nos d) MCB SPN 32 Amps-01 Nos Note - The lay out drawing of the panel shall be got approved by the contractor before panel fabrication and shall be fabricated from CPRI approved manufacturer.
M&L for earthing using GI earthing strip 32 x 6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed.
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size of make of Sudhir Enterprises or equivalent to Bajaj/Crompton
S&F flame proof WP rotory switch/Isolator 230 Volt 16 A double pole ON/OFF with cable termination box in LMS of Make Sudhir Enterprises complete all as specified and directed by the Engineer-in-charge.
M & L for point wiring with PVC insulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including in stove enammeled steel conduit not less than 25 mm dia and accessories, fixed on wall / ceiling etc with neccessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including wire lugs complete all as specified and directed
Supply & Fix Flame proof 2/4 way threaded type junction box made of material LM6 with plain cover of dia 80mm, depth 40mm confirm to Cat No JB/153 of sudhir or equivalent to Bajaj/Cromton complete all as specified and directed.
M&L for FLP flexible metallic hose conduit of suitable size M20/3/4" Conduit M x M /FM x M/F x F 300 mm complete all as specified and directed by the Engineer-in-charge. confirm to Cat No FH/199 of sudhir or equivalent to Bajaj/Cromton
S&F flame proof exhaust fans size of 380mm,1440 RPM, 230 V , including louvers 15" complete all as specified and directed by the Engineer-in-charge Confirm to Cat No EF/140 of sudhir or equivalent to Bajaj/Cromton
S&Fix wall mounted out door type double door LT Panel made out of 3 mm thick CRCA Sheet, the panel shall be provided with flame proof MCB DB made out of Cast aluminium alloy LM6, inside and out side light gray epoxy powder coating shade, 'O' ring endless neoprene rubber gasket, with 1 No. cable entry for incoming cable and three Nos cable entry for out going circuits with and including cable gland and stopping plug, 1 No MCB SPN 32 Amp as incoming and 1 Nos MCB SP 6 to 32 Amps for out going connections IP 65 protection as per IS 2147/1962. The panel shall be powder coated, front openable and locakable with key and shall be fabricated from CPRI approved manufacturer complete all as specified and directed.
Supply an Fix CIMFR Certified 1X 60 Watts LED Flame proof Fitting, wellglass in die cast AI housing with heat resistance toughetned complete with all acessories and including connecting up with three core flexible multi strand copper conductor of 2.5 Sqmm, drawn through steel conduit confirm to Cat No FWR1315-60-CDL of crompton /Sudhir complete all as specified and directed.
Supplying, fixing, jointing and testing, ISI marked, heavy grade , class C, MS pipe of dia 100 mm, conforming to IS: 1239-1982, with all fitting such as bend,flange,nuts,bolts etc and including weldings required for marking any type of branches with any pipe line sizes, laid in tranches / along the walls complete all as specified and directed.
Supply and fix fire hydrant landing valve type (single head outlet) of 63mm dia of size, including gasket, bend, flange etc conforming to IS: 5290 complete all as specified and directed.
Supply and fix fire hydrant stand post 80mm dia to fix single out fire hydrant valve confirming IS:908.
Supply, fixing, fire hose cabinet box of size 800X600X250 mm, oudoor type Made out from 18 Gauge MS sheet duly painted with 2 coats of red colour synthetic enamel paint over a coat of redoxide primer with double leafed glazed shutters (glaged with 4mm thick glass) suitable for housing of 2 length of canvas hose, nozzel including pedestral and foundation complete all as specified and directed.
Supply and fix 63 mm dia 30 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903 complete all as specified and directed.
Supply and fix gunmetal hand controlled chromium plated branch pipe 63mm dia with 12.5 mm Nozzle size with male insert provsion and incorporated with arrangments for Jet stream, spray and shut off.
Supply and fix fire extinguisher CO2 type 4.5 Kg capacity conforming to IS 15683 light weight squeeze grip type.
Supply and fix fire extinguisher dry chemical type 25.0 Kg capacity conforming to IS 10658, trolley mounted.
Supply and fix fire extinguisher dry powder (ABC) type 9.0 Kg capacity conforming to IS 15683.
Supply and fix fire bucket (dry sand) conforming to IS 2546.
Supply and fix fire hook of size 2 ft. Note : A sum of Rs 800.00 towards sch of credit shall be deducted to arrive the contract sum.
Parmatma Enterprises
H R ENGINEERS
SRINIVASA BUILDERS
mp construction co
Joy builders
sahajanand const co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .