Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹44.2 L+₹3.7 L (9.06%)Rejected-AOC | L2 | Rejected-AOC BEING NO L1 | |
| 3 | L3₹44.9 L+₹4.4 L (10.9%)Rejected-AOC | L3 | Rejected-AOC BEING NO L1 | |
| 4 | L4₹45.0 L+₹4.5 L (11.1%)Rejected-AOC NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L4 | Rejected-AOC BEING NO L1 | |
| 5 | L5₹48.0 L+₹7.5 L (18.4%)Rejected-AOC | L5 | Rejected-AOC BEING NO L1 |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
8 Mar 2023, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIRS TO E/M INSTALLATIONS OF B/R NATURE (LIGHT FITTINGS, PAINTING OF FOOT PATH, SHED, ROOF TREATMENT, SANITARY FITTINGS, ELECTRICAL FITTINGS AND MISC REPAIR WORKS) IN THE AREA OF AGE E/M NO-1 OF GE (U) SECUNDERABAD
2023_MES_580332_1
GE (U)/SEC/TOKEN/69 OF 2022-2023
Open Tender
Civil Works
Item Rate
270 days
SECUNDERABAD
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹99,800
Yes
11 Aug 2023
10 Feb 2023
15 Mar 2023
10 Feb 2023
8 Mar 2023
24 Feb 2023
Amount
PART-I : REPAIRS OF B&R NATURE M&L for demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level)complete all as specified and directed.
M&L PCC 1:4:8, type C-2 (40mm graded aggregate) in 100 mm thick as a sub base of floor including necessory form work complete all as specified and directed.
M&L for 40mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in flooring including necessory form work and finishing the top surface even & smooth, without using extra cement complete all as specified and directed.
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in any type of soils complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for moorum/ red bajiri filling including spreading levelling ,watering and consolidated to gradiant and camber required all as specified and as directed.
Hardcore of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for Shingle or gravel, spread, levelled and consolidated to gradient required of 50mm spread thick as specified for transformer yards etc
M&L for machine pressed interlocking paver blocks of 80mm thick with grey cement and no pigmet any shape and size confirming to IS 15658-2006 of M-40 grade all specified and directed
M&L for fine aggregate ( course Sand) as in back layer and cushioning for interlocking paver blocks, spread and required levelling etc., complete all as specified and directed.
M&L for chequerred cement concrete tiles 20 cm x 20 cm x 25mm thick with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors over and including 20 mm thick screed bed in cement and sand mortar 1:6, complete all as specified and directed.
M&L PCC 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) as in steps, plinth courses, parapets, copings, bed plates, kerbs etc. water troughs and the like including necesaary formwork,complete all as specified and directed.
Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering complete all as specified and directed.
Dismantling timber scantling of any section in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
S&F steel work in tubular trusses / poles (unframed) including purlins, rafters and special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade St-240 complete all as specified and directed.
M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws including ridge complete all as specified and directed.
Excavation in post holes (or similar holes) each n.exc 0.50 cu.m getting out in any type of soils, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm complete all as specified and directed.
M&L PCC 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) in foundations, filling and mass concrete
M&L for mild steel works in fencing post and struts incl cutting tops to shape as directed, drilling holes, notching wire, etc.,FI fillets (for securing wire mesh etc) icl all necessary drilling bolting or riveting etc., and similar work conforming to Fe-290 Gde E-165 complete and incl dismantling old steel work all as specified and directed.
S&Fchain link fencing incl MS galvanised fencing wire not less than 3.8mm dia, mesh of max size 100x100mm weighing not less than 3.08 kg/sqm, fixing to any type of standards rails, straining bolts etc., including provision of binding with mild steel wire annealed not less than 0.9mm dia including dismantiling old unserviceable mesh complete all as specified and directed.
S&F Framed mild steel work such as grills, grating, gates with ends of bars shouldered and / or rivetted, or forged into spikes, framed gurad bars, barred iron doors, ladders, framed balusters, walk ways railings and similar work confirming to Fe- 290 Gde E-165 of any section and sizes, including taking down old gates or ladders of any size and in any position complete all as specified and directed.
M&L for preparation of new steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new steel surfaces of any description not exc 10 cm width or girth and priming with red oxide zinc chrome and painting with two coats of synthetic enamel paint complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar or cement lime mortar including all quoins, arches,pillars, ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L Pre-cast cement concrete block masonry Type C1 1:3:6 (20mm graded aggregate) with solid blocks, exc. 10cm in width and setting in cement mortar 1:6 complete
M&L for brick work with sub class B bricks, straight or curved on plan exc 6 m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L walling of Random Rubble masonry, uncoursed, well bonded, bedded and solidly hearted and built in cement mortar (1:6) complete all as specified and directed.
M&L PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundations filling and mass concrete complete all as specified and directed.
Taking down cement plaster of any description from existing old walls (to receive plaster) including raking out joints, hackisng for key, scrubbing down with water etc.., complete all as specified and directed.
Rendering 10 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified and directed.
Rendering 15 mm thick in cement and sand mortar 1:6 on other than fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified and directed.
Rendering 5 mm thick in cement and sand mortar 1:3 on concrete surfaces of ceiling including finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 15mm thick in CM 1:4 mixed with WP compound on brick work or concrete surface etc. finished even and smooth without using extra cement as in roof surfaces etc. all as specified as in Water storage sumps etc. Note:Water proofing compound shall be measured seperately.
Rendering 10 mm thick in cement and sand mortar 1:3 on concrete surfaces of roof etc. mixing with water proofing compound including finishing the surface even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately
Supply only liquid water proofing compound
M&L for preparing newly plastered surfaces of Walls and applying with three coats of white wash complete all as specified and directed.
All as per item No.37 above, but on ceilings.
M&L for preparation of newly treated surfaces and apply two coat of oil bound distemper over one coat of chalk whitening to walls complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
Taking down cement or cement lime plaster from roof top inluding removing old water proofing roof treatment of any description and cleaning surfaces with wire brush, removing dust, debris material obtained from demolition out side Def land complete all as specified and directed
M&L for cleaning concrete surfaces with wire brushes, removing dust and applying water proofing treatment as under :- (i) Apply oil bound bitumen [email protected] litre/sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 kg/litre at 25 degree celsius on the prepared dry roof surface. (ii)Laying APP polymer modified membrane weight @3.8kg/sqm and 3mm thick reinforced with non woven polyester mat by torch applicationon membrane with min 100mm over lap (iii) Top of membrane surface shall then be finished with solar reflective bituminous aluminium paint @ 0.1 ltr/sqm complete all as specified and directed
M&L for Cement concrete 1:2:4, type B-1, using 20mm graded stone aggregates incl necessary formwork in lintels upto 1.5m clear span, cills, steps; plinth courses, parapets and railings upto 60 cm in height, copings, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for TMT bars 10mm dia and above TMT bars bent to shape required, including cranking, bending and binding with mild steel annealed wire not less than 0.9mm dia complete all as specified and directed.
All as per item No.44 above above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc
M&L for pre cast cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc), shelves and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required for depth exc one brick but not exc. two bricks
All as per item no. 47 above but in stone walls built in cement mortar or in cement lime mortar
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.5 sqm and not exceeding 4.00 sqm each complete all as specified and directed.
All as per item no 49 above but n.exc 1.5 sqm
Taking down shutters of any description, area exceeding 1 sqm and not exceeding 2.00 sqm each complete all as specified and directed.
Refixing the shutters area exceeding 1 sqm and not exceeding 2.00 sqm each, including easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc complete all as specified and directed.
M&L in repair for Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed in second class hard-wood
S&F for 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F in repair for Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, complete all as shown in drawing of relevant item in MES, schedule Part-II , 2004 complete all as specified and directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as a gap insert for top rail and bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S frame welded / sealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side as per specification and drawings complete all as specified and directed.
S&F for Glazed and skeleton shutters, 25mm thick in 2nd class hardwood, open rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (b); supplied and fitted to chowkats complete all as specified and directed in any type of buildings incl Over head tanks.
S&F for Small fittings in 2nd class hardwood, such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each complete all as specified and directed.
S&F for 125 mm size butt hinges ,extruded Aluminium alloy with galvanised mild steel hinge pin,type-C-21. (ISI Marked), rolled mild steel complete all as specified and directed.
All as per item no. 59 above but for 100 mm size butt hinges
All as per item no. 59 above but for 100 mm size butt hinges in repair
S&F for 150mm size Aluminium anodized barrel Tower bolts of extruded section and fixed complete all as specified and directed.
All as per item no. 62 above but for 100mm size in repair
S&F for 150mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed.
S&F for 100mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed.
S&F for 300mm size extruded aluminium alloy sliding door bolt, fabricated type anodized complete all as specified and directed.
S&F for 250mm size extruded aluminium alloy sliding door bolt, fabricated type anodized complete all as specified and directed.
M&L for painting to new wood or wood based surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, priming with pink primer (one coat) finished with two coats of synthetic enamel paint complete all as specified and directed.
M&L for 4 mm thick sheet glass, ordinary quality and glazing with beading or PVC beads in square exceeding 0.5 square metre in each pane complete all as specified and directed.
S&F for steel windows with side hung shutters including hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded complete all as specified and directed.
M&L for 3 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and directed.
All as per the srl item No. 71 above but for 4mm thick glass
M&L for hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new ones glazed with oil putty fixed with beads complete all as specified and directed. Note: Reglazing shall be measured as a new work
S&F for stainless steel wire-cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
All as per the srl item No. 74 above but fixed in repair.
S&F for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge
M&L for 5 mm thick sheet glass, ordinary quality and glazing with beading or PVC beads in square exceeding 0.5 square metre in each pane complete all as specified and directed.
M&L for veneered decorative plywood 9/12 mm thick, grade 1 (with BWR resin) with decorative face veneers on both face, fixed with screws to timber frame work as in aluminium door shutter etc. complete all as specified and directed.
S&F for door closer of cast iron body, hydraulically regulated, designation No 2, universal type, suitable for door shutters of weight between 36 to 60 Kg, ISI marked, fixed in repairs complete all as specified and directed.
M&L for dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) rubbish off the premises complete all as specified and directed.
M&L for non skid coloured ceramic tiles 7 to 8mm thick area of each tile exceeding 0.06 but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for glazed ceramic tiles 7mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar 1:4, complete all as specified and directed.
M&L for non skid coloured ceramic tiles 7 to 8mm thick area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per srl item No. 83 above but on skirting including back layer of 10mm thick plaster in CM 1:4.
M&L Machine cut cudappah stone slab 20-25mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
S&F for Sink with draining board made out of stainless steel 1.00 mm thick sheet for kitchen with plugs, washers and wastes including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm with bowl size 410 mm x 330mm x 160mm supplied and fixed in repairs complete all as specified and directed.
M&L for Vitreous China squatting pan “Orissa pattern” size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) including connection to flush pipe, anti syphonic pipes, 'P' or 'S' trap set in and including concrete etc complete including making good floor fixed in repairs complete all as specified and directed.
M&L for PVC low level flushing cistern, ISI marked, valveless, syphonic action type, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC flush pipe 32mm dia supplied and fixed in repairs complete all as specified and directed.
M&L for vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe, complete incl providing and fixing plugs, bedding urinal in cement mortar, fixing automatic flushing cistern with brackets, flush pipe, and Union for discharge pipe, waste couplingetc fixed in repairs complete all as specified and directed.
M&L for vitreous china wash basin, white, flat back, size 550x400mm including fixing taps, waste fittings and union, plugs and chains and connecting up to supply pipes, wastes or traps etc. and including brackets fixed in repairs complete all as specified and directed.
S&F for PVC connection 15 mm size, of length 450 mm, with PTMT nuts supplied and fixed in repairs complete all as specified and directed.
S&F in repairs grating doom 125mm dia with waste hole of PTMT fixed on floor/nahani trap with cement mortar, fixed in repairs complete. (Minimum weight 40 gms) complete all as specified and directed.
Taking up or down steel tubing and connections, 15 mm bore fixed on walls, floors or ceiling etc.,complete all as specified and directed.
All as per item No. 94 above, but 20 mm bore.
S&F for 15mm bore tubes, medium grade, galvanised with and including all fittings fixed to walls, floors, or ceiling or laid in floors etc., complete all as specified and directed.
All as per srl item No.96 here in before but 20mm bore.
S&F for stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, for bore dia of pipe 15 mm, supplied and fixed in repairs complete all as specified and directed.
All as per item No. 98 here- in- before but 20 mm bore.
S&F for bib taps, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, for bore dia of pipe 15mm, supplied and fixed in repairs complete all as specified and directed.
S&F Bib tap standard of PTMT fancy type any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-105gms) screwed for iron pipe 15 mm bore, supplied and fixed in repairs complete all as specified and directed.
Supply only for Pillar taps cast copper alloy, with capstan head, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nut, screwed for iron pipe 15 mm bore, supplied and fixed in repairs complete all as specified and directed.
Supply only for Pillar taps of PTMT, fancy type any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-120gms) screwed for iron pipe 15 mm bore, supplied and fixed in repairs complete all as specified and directed.
S&F for PVC (SWR) pipes 110 mm bore single socketed, in any length with and including rubber ring joints, fixed on walls complete including taking down old existing PVC rain water pipe complete all as specified and directed.
S&F for PVC (SWR) bends (any radius) 110 mm bore complete all as specified and directed.
S&F in repair Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), 500litres capacity, hoisted and fixed in position all as specified in SSR Part I
S&F in repair for ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore (minimum weight 210 gms), fixed in repairs complete all as specified and directed.
M&L for preparing old treated surfaces of walls (plastered or unplastered surfaces) and applying one coat of white wash on old decorated surfaces complete all as specified and directed.
All as per Srl item No. 108 above but on ceiling
M&L for preparing old treated surfaces of walls (plastered or unplastered surfaces) and applying one coat of cement base paint complete all as specified and directed.
M&L for complete removal of existing treatment of walls (plastered or unplastered surfaces) and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparing old treated surfaces of walls (plastered or unplastered surfaces) and applying one coat of oil emulsion distemper (white / tinted) complete all as specified and directed.
M&L for preparing old treated surfaces of walls and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparing old painted wooden/wood based surfaces over 10cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified and directed.
M&L for preparing old painted steel surfaces over 10 cm width of girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified and directed.
M&L for painting floors with one coat of ready mixed paint paint (any colour as specified) after cleaning by brooming and washing the floor with water to remove dust etc. complete all as specified and directed.
M&L for Rewriting or Repainting letters or figures (Block, Roman, Italic or Indian) n exc. 30cm high complete all as specified and directed.
Surface dressing n exc 15 cm deep in any type of soils complete all as specified and directed.
M&l for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over prepared surfaces including complete removal of existing treatment all as per below mentioned stages for complete exterior including all walls, all columns, beams, stairs, ceilings, parapets, top roof etc for 2.50 lakh Gallon capacity Overhead tanks:- (i) Complete removal of existing treatment: The surfaces shall be cleaned to remove loose dirt or dust, lichen, algae, fungi or any organic growth by use of stiff brush. Then the surface is washed well and allow water to dry. All cracks, voids and minor damages shall be patched/repaired with white cement putty or with Plaster of Paris, prior to application of paint.In case of old surfaces where excessive fungal/algal growth is observed the surface should be bio washed as per manufacturers instructions. Allow the surface to dry before it is ready for painting. (ii) Primer Coat: Over this prepared surface apply a coat of acrylic emulsion exterior primer as per manufacturer’s instructions. This shall be allowed to dry for 4 to 6 hours before application of final paint. (iii) Finishing Coat: Acrylic Exterior Emulsion paint of premium quality 100% Acrylic shall be applied in two coats as per manufacturer's instructions. Paint shall be applied with brushes or roller and shall be allowed to dry for 3 to 4 hours between subsequent coat. (iv) Finishing to Handrails if any: Preparing old painted steel surfaces and applying one coat (finishing coat) of synthetic enamel paint complete Note: Quoted rates are deemed to be inclusive of necessary scaffolding arrangement for the complete work and provision of all precautions like safety helmet, safety belts etc to the labours. Quoted rates are also deemed to be inclusive of necessary life insurance coverage to all workers employed by contractor. The bidders are requested to visit each site before quoting.
All as per item no 119 above but for 1.5 lakh Gallon capacity Overhead tanks
All as per item no 119 above but for 50,000 Gallon capacity Overhead tanks
All as per item no 119 above but for 25,000 Gallon capacity Overhead tanks
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar for 150mm internal dia
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for laying pipes etc or for manhole shaft n exc 10 sqm on plan and n exc 1.5m in depth and getting out in hard/ dense soil
Returning, filling in , including spreading, levelling,watering and well ramming in layers not exceeding 25 cms in soils complete
Removing excavated soil material exc. 250 m but n exc. 500 m and depositing where directed
Supply & lay Double wall corrugated pipes High density Polyethylene DWCPE (SN8) pipes, laid in trenches/ floors over PCC bed; jointed with and including necessary fitttings such as bends, sockets and other connected accessories etc complete all as specified and directed for Nominal size 150mm dia pipes (ID 148.5mm/ od 172.5mm) etc. complete all as specified and directed.
M&L for Soakage wells of size 1.2 M dia X 1.5 M effective depth incl excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of Cement Concrete 1:2:4, made of Brick masonary in CM 1:4, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/SWR complete filled with brick bats etc complete all as specified and directed as per HQ CECZ TD Drawing No TD/ST/744 & 746.
PART-II : REPAIRS OF INTERNAL ELECTRIFICATION (E&M) Taking down Copper / aluminium point wiring (light, socket or power Points) complete, including fixture and fitting such as switches, ceiling roses, pendents, sockets,etc. removing materials to store for keeping safe custody or for taking credit and making good disturbed surfaces of walls, floors etc as per existing all as Specified and directed by Engineer-in-Charge
Material and labour for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade FRLS cable stranded copper conductor single core in casing caping of suitable size complete with sunken iron pressed steel terminal box 2 mm thick for fitting mounting switch/ sockets regulators etc with hylam sheet 3 mm thick cover and with 1.5 sqmm PVC insulated copper conductor earth wire and connected to common earth dolly for the following points all as specified and directed.
One light point controlled by one switch
One 5A 2pin/3pin switch socket out let multipurpose on same board.
One 3 pin socket point 5A controlled by switch on independent board
Material & labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :-
One light point controlled by one switch
One 5A 2pin/3pin switch socket out let multipurpose on same board.
One 3 pin socket point 5A controlled by switch on independent board
All as per item No 131 above but for 3 pin socket outlet 15 Amp independent with cable 2.5 sqmm unsheathed stranded 1100 Volts grade complete with 1.5 sqmm PVC insulated earth wire and connecting to earth dolly all as specified and directed.
Supply and fix switch piano type 5 Amp single pole one way complete all as specified and directed.
Supply and fix ceiling rose surface backelite min dia 63 mm three terminal complete all as specified and directed.
Supply and fix switch socket combination 2 in 1, 5 Amp flush type complete all as specified and directed.
Supply and fix switch socket combination multipurpose 3 pin 15 Amp flush type complete all as specified and directed.
Supply & fix MCB distribution board SPN 08 way double door with bus bar complete all as specified.
Supply and fix MCB SPN 240 Volts 5 Amp to 32 Amp breaking capacity 10 KA rating complete all as specified.
Supply and fix MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed.
M & L for Earthing of DB, complete with galvanised steel earth plate electrode 60Cm x 60Cm x 6 mm thick directly burried in ground ( eath pit not less than 2.25 M deep below the normal ground level conneceted to galvanised earth lead wire 4 mm dia by mens of bolts, nuts, check nuts and washers of galvanised iron steel including necessery excavation earth work PCC chamber CI chamber cover protection pipe watering pipe etc. (Complete all as shown in electrical plate No 3 and conected to earthing test point complete including excavation earthwork, PCC chamber, chamber cover ,funnel watering and protection pipe etc all specified and directed.
M&L Earthing continuity galvanised 4 mm wire or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engineer-in-Charge.
S&F in repairs of LED indoor decorative aluminium extruded T5 lED batted integrated type tube light fitting, suitable and including 1x20W, 230V, bipin holders, connector block etc complete with all accessories internally prewired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes all as specified and directed. Make: C&S cat no LTTB4F20WLED/W or techno commercial equivalent in Bajaj/Halonix/Polycab as approved by GE.
S&F in repairs of LED indoor decorative aluminium extruded T5 lED batted integrated type tube light fitting, suitable and including 1x10W, 230V, bipin holders, connector block etc complete with all accessories internally prewired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes all as specified and directed. Make: C&S cat no LTTB2F10WLED/W or techno commercial equivalent in Bajaj/Halonix/Polycab as approved by GE.
Taking down DBs with sheet metal enclosure 8 way SPN DBs along with SPN / SP etc all as specified and directed.
K LAKSHMAN SINGH AND CO
SN POWER TECH
M/S SIRI BUILDERS
M Shyam Sunder
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .