Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC NO 24 ANANDA MUTHUMARIAMMAN KOIL STREET KUYAVARPALAYAM PUDUCHERRY 605013 | PONDICHERRY | PUDUCHERRY | 605013 | L1 | Accepted-AOC AOC | |
| 2 | L2₹10.5 L+₹46,654.90 (4.64%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | Not Admitted-Fee/PreQual/Technical NO 14 SMALL STREET MANAPET PO BAHOUR COMMUNE PUDUCHERRY 607 402 | CUDDALORE | TAMIL NADU | 607402 | - | Not Admitted-Fee/PreQual/Technical Others-Withdrawn tender bid |
Tender Value
₹9.2 L
EMD Value
₹18,349
Closing Date
3 Oct 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, PHD, PWD, Puducherry
Executive Engineer, PHD, PWD, Puducherry
Realignment and extension of sewerage facilities to areas of Nessar street in Isravel nagar of Indra nagar Constituency (Zone - VI), Puducherry
2024_PWDC2_16607_1
14/PHD/2023-24/04
Open Tender
Civil Works - Water Works
Item Rate
60 days
Uppalam
Please refer Tender documents.
3 documents required · 3 mandatory
₹525
₹18,349
30 Dec 2024
27 Sept 2024
4 Oct 2024
27 Sept 2024
3 Oct 2024
27 Sept 2024
Amount
Cutting open B.T. Road or macadam road for laying water main / sewer lines and stacking the usable materials on road side for reuse in road works.
Earth work excavation above water level and depositing on bank in sandy silt or other soil, wet sand or silt, light black cotton soil or clay, sandy loam & ordinary soil for I.C's man hole, well, infiltration, suction well including driving shoring materials etc. for excavation purpose and removing the shoring materials and refilling the trenches with excavated earth complying with standard specification., complete - For first depth of 2 metres (using close timbering).
Earth work excavation above water level and depositing on bank in sandy silt or other soil, wet sand or silt, light black cotton soil or clay, sandy loam and ordinary soil for I.C’s manhole, well, infiltration, suction well including driving shoring materials etc. for excavation purpose and removing the shoring materials and refilling the trenches with excavated earth complying with standard specification, complete - For second depth of 2 metres (using close timbering).
Construction of circular manholes in brick masonry with country bricks of class designation 35 in circular manholes, providing and laying 200 mm thick of cement concrete 1:4:8 (one cement, four coarse sand and eight hard broken granite stone aggregate of 40 mm nominal size), side walls with country bricks in cement mortar 1:4 (one cement and four sand) as shown in drawings. Cement plastering with inside and outside walls in CM 1:3 (one cement and three fine sand) with 20 mm thick using Ordinary Portland Cement (OPC), providing, benching and channeling with CC 1:11/2:3 (one cement, one and half sand and three hard broken granite stone aggregate of 20 mm nominal size), finishing bottom 20mm thick cement plaster in C.M 1:3 (one cement and three fine sand) with neat cement using OPC cement, providing and fixing of 600 mm dia Extra heavy duty SFRC covers with frame made as per IS 12592-2002 (I & ii) in accordance with "CPHEEO Manual on Sewerage & Sewage treatmet and relevant IS Codes". Fixing of C.I/PVC steps as shown in drawings, but excluding its cost which will be paid separately. The cost also includes the cost of curing and testing of the manholes for its water tightness. A drop in water more than 5 cm in 24 hours shall not be permitted. The rate including cost of circular SFRC cover and frame 600 mm dia, but excluding the cost of earth work excavation - 1200 mm dia and 1000 mm deep.
Extra/rebate for every additional/ reduction in depth of 0.10 m in 23 cm thick wall or part thereof over the following manhole size for circular manhole - Country Bricks - 1200 mm dia and 1000 mm deep.
Construction of circular manholes in brick masonry with country bricks of class designation 35 in circular manholes, providing and laying 200 mm thick of cement concrete 1:4:8 (one cement, four coarse sand and eight hard broken granite stone aggregate of 40 mm nominal size), side walls with country bricks in cement mortar 1:4 (one cement and four sand) as shown in drawings. Cement plastering with inside and outside walls in CM 1:3 (one cement and three fine sand) with 20 mm thick using Ordinary Portland Cement (OPC), providing, benching and channeling with CC 1:11/2:3 (one cement, one and half sand and three hard broken granite stone aggregate of 20 mm nominal size), finishing bottom 20mm thick cement plaster in C.M 1:3 (one cement and three fine sand) with neat cement using OPC cement, providing and fixing of 600 mm dia heavy duty SFRC covers with frame made as per IS 12592-2002 (I&II) in accordance with "CPHEEO Manual on Sewerage & Sewage treatmet and relevant IS Codes". Fixing of C.I/PVC steps as shown in drawings, but excluding its cost which will be paid separately. The cost also includes the cost of curing and testing of the manholes for its water tightness. A drop in water more than 5 cm in 24 hours shall not be permitted. The rate including cost of circular SFRC cover and frame 600 mm dia, but excluding the cost of earth work excavation - 1200 mm dia and 1600 mm deep.
Extra/rebate for every additional/reduction in depth of 0.10 m in 34 cm thick wall or part thereof over the following manhole size for circular manhole - Country Bricks - 1200 mm dia and 1600 mm deep.
Fixing of 150 mm wide PVC encapsulated steps in the manholes with 200 x 200 x 100 mm CC block in cement concrete 1:1.5:3 (one cement, one and half sand and three hard broken granite stone aggregate of 20 mm nominal size) all as shown in drawings.
Earth work excavation above water level and depositing on bank in sandy, silt or other soil, wet sand or silt, light black cotton soil or clay, sandy loam and ordinary soil for infiltration, gallery siphon or connecting pipe line including driving shoring materials as mentoned below. Removing the shoring materials and refillign with excavated earth complying with standard specification etc. complete - First depth of 2 m (using close timbering).
Earth work excavation above water level and depositing on bank in sandy, silt or other soil, wet sand or silt, light black cotton soil or clay, sandy loam and ordinary soil for infiltration, gallery siphon or connecting pipe line including driving shoring materials as mentoned below. Removing the shoring materials and refillign with excavated earth complying with standard specification etc. complete - Second depth of 2 m (using close timbering).
Providing, laying and jointing HDPE pipe PE 100 x PN 6 conforming to IS specification and ISI marked including transportation to the site, lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, including jointing and excluding specials such as bends, tees, threaded pieces, couplers, reducer, endcaps etc., complete as per IS and CPWD specifcation - 200 mm dia.
Providing, laying and jointing PVC-U pipes for use in under ground drainage and sewerage system conforming (SN8) to IS specification 15328-2003 and ISI marked including transportation to the site, lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, including cost of solvent cement, excluding UPVC specials such as bends, tees, threaded pieces, couplers, reducer, end caps etc, complete all as per IS and CPWD specification - 110 mm dia.
Providing and fixing in position PVC-U moulded plain coupler (Finolex / jain)(SN8) conforming to IS 7834 part II and ISI marked, including labour charges for jointing, jointing materials etc, complete - 110mm dia . PVC coupler (mould)
Providing and fixing in position UPVC moulded endcap (Finolex / jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked,including labour charges for jointing, jointing materials etc, complete - 110mm dia
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete. - for pipes 100 to 230 mm diameter.
Excavation for roadwork in soil with hydraulic excavator of 0.9cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections and transporting to the embankment location with all lifts and lead upto 1000m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Cleaning the site by removing the slushy soil on both the sides of road and making the road fit for laying WBM and making smooth surface for vehicular traffic including disposing the same within 2 Km lead.
T.GOPINATHAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .