Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 CrAccepted-AOC ANANDI NIWAS MAIN ROAD ROURKELA 769001 | ROURKELA | SUNDERGARH | ODISHA | 769001 | ₹4.6 Cr Quoted ₹4.7 Cr | L1 | Accepted-AOC Due to L1 rate quoted |
| 2 | L2₹4.7 Cr+₹5.3 L (1.14%)Rejected-Finance | ₹4.7 Cr+₹5.3 L (1.14%) | L2 | Rejected-Finance Other than L1 rate quoted |
| 3 | L3₹4.7 Cr+₹7.7 L (1.65%)Rejected-Finance | ₹4.7 Cr+₹7.7 L (1.65%) | L3 | Rejected-Finance Other than L1 rate quoted |
| 4 | L4₹4.8 Cr+₹15.3 L (3.28%)Rejected-Finance | ₹4.8 Cr+₹15.3 L (3.28%) | L4 | Rejected-Finance Other than L1 rate quoted |
| 5 | L5₹4.8 Cr+₹18.9 L (4.06%)Rejected-Finance | ₹4.8 Cr+₹18.9 L (4.06%) | L5 | Rejected-Finance Other than L1 rate quoted |
Tender Value
₹5.7 Cr
EMD Value
₹6.1 L
Closing Date
22 Mar 2025, 6:00 pmClosed
Chief Engineer Jalandhar Zone Jalandhar Cantt
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
Upgradation of infrastructure alongwith connected works in store yard at GE (Engr Park) Jalandhar cantt
2025_MES_696366_1
81084/E8
Open Tender
Civil Works
Item Rate
548 days
Jalandhar Cantt
As per NIT Documents
9 documents required · 9 mandatory
₹3,000
Garrison Engineer (East) Jalandhar Cantt
₹6.1 L
Yes
22 May 2025
4 Feb 2025
29 Mar 2025
4 Feb 2025
22 Mar 2025
15 Mar 2025
Amount
Surface excavation n. exc. 30cm deep and averaging 15cm deep and getting out in soft/ loose soil, complete all as specified and directed.
Rough excavation n. exc. 1.50m deep and getting out in soft/ loose soil, complete all as specified and directed.
Excavation in post holes (or similar holes) each hole n. exc. 0.50 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm and removing surplus soil to a distance n. exc. 50m and making good surface, complete all as specified and directed.
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m deep for foundations, laying under ground cables etc. and getting out in soft/ loose soil and getting out complete all as specified and directed.
Excavation in trenches exc. 1.5m wide and n. exc. 3.0m deep for foundations, laying under ground cables etc. and getting out in soft/ loose soil and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 25 cm using soil obtained from excavation, complete all as specified and directed.
Removing excavated soil to a distance n. exc. 50m and depositing where directed at a level n. exc. 1.5 metre above the starting point, complete all as specified and directed.
Removing excavated material exc. 500m but n. exc. 1.50km and depositing where directed as in embankment at a level n. exc. 1.5 metre above the starting point or filling in low lying area including spreading in layers n. exc. 30cm thick, watering, ramming/ rolling and finishing to required shape/ size complete all as specified and directed.
Removing excavated material n. exc. 50m and depositing where directed as in embankment at a level n. exc. 1.5 metre above the starting point or filling in low lying area including spreading in layers n. exc. 30cm thick, watering, ramming/ rolling and finishing to required shape/ size complete all as specified and directed.
Borrowing earth from outside MoD land and depositing including forming embankments, spreading in layers n. exc. 30cm thick, watering, ramming/ rolling and finishing to required size, shape etc. n. exc. 1.5m high from base as in road berms, complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete, complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling, mass concrete and foundation of poles, complete all as specified and directed.
PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping, complete all as specified and directed.
M&L for RCC M-20 Design mix (20mm graded aggregates) for foundation, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.
M&L for RCC M-25 Design mix (20mm graded aggregates) for foundation, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.
M&L for RCC M-25 Design mix (20mm graded aggregates) as in beam, cantilevers, bressumers, lintels and similar work, complete all as specified and directed.
M&L for RCC M-25 Design mix (20mm graded aggregates) as in columns, pillars, posts and struts, complete all as specified and directed.
M&L for brickwork with fly ash bricks, straight or curved on plan exc. 6m mean radius, built in cement mortar (1:6), complete all as specified and directed.
Use and waste of form work to sides of concrete foundations, footings, base of columns, raft and raft beams, side and soffit (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surface of concrete, complete all as specified and directed.
Use and waste to formwork to sides and soffits of floor or roof beams, beam, lintels, including supports, overhangs, etc. for rough finished surface of concrete, complete all as specified and directed.
Use and waste form work to sides of pillars, posts, columns and similar works rough finished square, rectangular or polygonal surfaces of concrete, complete all as specified and directed.
M&L for TMT bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clip, complete all as specified and directed.
M&L TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clip, complete all as specified and directed.
S&F mild steel work as in fencing posts and struts fixed independently, including cutting top to shape as directed, drilling holes, notching for wire etc., flat iron fillets (for securing barbed wire and mesh etc.) including all necessary drilling, bolting or riveting/ welding etc. and similar work quality conforming to Fe-290 Gde E-165, complete all as specified and directed.
S&F galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts including, securing or tying at crossings with and provision of galvanised MS wire, staples or steel pins etc. complete all as specified and directed. (Each line wire shall be measured).
Supply only chain link fencing any mesh and size, complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, complete all as specified and directed.
S&F MS bars 10mm dia and over cut to length bent to shape including cranking bending etc., for fixing chain link fencing complete all as specified and directed.
S&F mild steel screw bolts (machine made) 5 to 10mm dia with hexagonal or square head at one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, n. exc. 5cm long, complete all as specified and directed.
S&F for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing with other accessories with necessary cutting, welding, and bending as site requirement complete and fixing to column structure complete all as specified and directed confirming to Fe-410-W (Gde-E-250) quality A, complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surface finished even and smooth (without using extra cement), complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surface finished even and smooth (without using extra cement), complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement), complete all as specified and directed.
M&L for preparation of new plastered wall surfaces and applying two coats of cement base paint on newly plastered surfaces of wall over a coat of primer, complete all as specified and directed.
M&L concrete bed to 300mm dia drain pipes in cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate including packing under and completely surrounding pipes after they are laid and tested, complete all as specified and directed.
M&L concrete bed to 150mm dia drain pipes in cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate including packing under and haunching against sides of pipes after they are laid and tested, complete all as specified and directed.
M&L for 300mm bore reinforced concrete pipes of pipe, class NP3, laid and jointed with collars, complete all as specified and directed.
M&L for 150mm bore reinforced concrete pipes of pipe, class NP3, laid and jointed with collars, complete all as specified and directed.
Rolling and consolidation of formation surface in cutting of roads/ berms etc. to the required level, gradient and camber with 8 to 12 tons power road roller including filling in depressions which occur during process with approved earth, complete all as specified and directed.
M&L pre-cast for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in landings, manhole cover slabs, chajjas, shelves, road kerbs and similsr articles with plain, fair faces including chamfers, weathering, throating set in cement mortar (1:4) complete all as specified and directed.
M&L for 150mm thick soling (or sub base) with broken boulder or quarried stone, interstices filled, surface formed and rolled and consolidated with 8 to 12 tonne power roller to required camber and gradient, complete all as specified and directed.
M&L for 150mm thick water bound macadam (compacted thickness) (in two layers 7.5cm thick each) with graded broken stone aggregate of grading 2 (63mm to 40mm) using granite trap or basalt; spread, levelled, rolled and consolidated to required gradient and camber and rolled with 8 to 12 tonne power road roller, complete all as specified and directed.
M&L for preparing surfaces by brushing with wire brushes for removing caked mud etc., sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. and applying evenly a priming/ tack coat with paving bitumen VG-10 grade @ 10 kg per 10 sqm of road surface and laying 40mm thick bituminous premixed asphaltic semi dense concrete with 5.5% binder content using bitumen VG-30 grade by weight of total mix with mechanical paver rolled and compacted to required camber and gradient and rolled with 8 to 12 tonne power road roller, complete all as specified and directed.
M&L for premixed bituminous macadam laid/ rolled & compacted to required gradient & camber (consolidated thickness 75mm or less) with bitumen VG-10 @ 4% by weight of total mix, complete all as specified and directed.
M&L for preparing surfaces by brushing with wire brushes for removing caked mud etc., sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. and applying evenly a priming/ tack coat with paving bitumen VG-10 grade @ 5 kg per 10 sqm of road surface and laying 40mm thick bituminous premixed asphaltic semi dense concrete with 5.5% binder content using bitumen VG-30 grade by weight of total mix with mechanical paver rolled and compacted to required camber and gradient and rolled with 8 to 12 tonne power road roller, complete all as specified and directed.
M&L for preparing bituminous surface of road and marking broken centre line/ side line 2mm thick on road pavement and the like of any description and width with thermo plastic road marking paint applied hot with machine conforming to BS-3262 and according to specifications laid down by IRC & MOST (Ministry of surface transport) specifications 2001 (4th revision) complete all as specified and directed.
S&F cat eye ABS plastic with nail of size 120mm x 120mm, 43mm reflective glass colour white/ red/ yellow provided with steel zinc plated bolt 12mm dia and 120mm length for fixing to road by hammering, complete all as specified and directed.
M&L for forming contraction (Dummy) joints 65mm to 70mm deep x 10mm wide, filled with bituminous sealing compound grade 'A' complete all as specified and directed.
M&L for forming 20mm thick expansion joints in 150mm deep slab filled with pre-formed bituminous filler and top 30mm primed and sealed with bituminous sealing compound Grade ‘A’ complete all as specified and directed.
M&L preparation of new or previously untreated steel surface of any description over 10cm width or girth not otherwise described and applying two coats of synthetic paint over a coat of red oxide zinc chrome primmer, complete all as specified and directed.
S&F PVC (SWR) pipes 110mm dia for weep hole, single socketed, in any length for passing of rain water from compound wall, complete all as specified and directed.
S&F preformed joint filler (polymer based) 25mm thick confirming to IS-1838 (Part-III) for crumple joints, complete all as specified and directed.
Dismantling post or struts (Wood, Steel or RCC) any section, including taking out embedded portion and making good disturbed ground or embedded in concrete including removing from site, complete all as specified and directed.
Dismantling of galvanised mild steel barbed wire of any type or any size from RCC or iron post of any size, section etc. complete all as specified and directed.
Dismantling of galvanised mild steel fencing wire mesh any type and any size from RCC or iron post of any size, section, including taking out from frame complete all as specified and directed.
Supply, laying, connecting and testing XLPE insulated, PVC sheathed galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 4 core laid in trenches/ under road/ under floor/ along the wall, complete all as specified and directed.
M&L for earthing complete with GI earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically in a pit not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below ground level, covered on all sides with alternative layers of charcoal dust and common salt 15cm thick & connected to galvanised earth lead GI wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised pipe light grade 15mm bore from top of earth plate electrode upto test point and watering pipe 20mm bore GI light grade with funnel and wire mesh all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion, including PCC earth pit (1:3:6) type C-2 PCC having MS angle iron frame made of 25 x 25x 3mm covered with PCC cover including excavation and earh work, complete all as specified and directed.
Supply, erecting and fixing pressed cement concrete poles 9 meter long 102mm x 172mm at top and 102mm x 279mm at bottom class 10 complete as specified including painting of poles upto 1.5 mtr height from coping with two coats of synthetic enamel paint black & white alternate strips and numbering of poles as directed, complete all as specified and directed. Note:- PCC and earth work shall be measured & paid for separately.
M&L for PCC work (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of stay/ coping of poles including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and directed.
M&L for sand cushioning with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches, punned down to thickness of 18cm complete all as specified and directed. Note:- Punned down thickness of 18cm shall be measured for payment.
Supply and laying old size class 'B' bricks laid flat in trench across the cable with the length of brick perpendicular to the direction of cable length, adjacent/ abutting each other complete all as specified and directed.
S&F of PVC insulated, PVC sheathed three core, copper conductor cable 1100 volt grade of size 1.0 Sqmm drawn in and including stove enamelled steel conduit 20mm dia for connection purpose, complete all as specified and directed.
S&F LED street light luminaire 35 watt in epoxy powder coated pressure die-cast aluminium housing heat resistant toughened glass/ polycarbonate cover/ clear glass fixed with SS screws controlled with potted CVCC type, BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 4 KV minimum in circuit and 10 KV outside the driver but inside the fixture with IP-66, Class-1 protection for LED and control gear compartments with high power LED chips of rating 2.5 to 3 watt (maximum) with colour temperature 5700 K (max) and with secondary optics modular lenses provided to minimize glare and for better distribution of light suitable for voltage band 170 volts to 270 volts, power factor 0.95 (minimum) having efficacy 100 lumens/ watt, complete all as specified and directed.
S&F LED street light luminaire 70 watt in epoxy powder coated pressure die-cast aluminium housing heat resistant toughened glass/ polycarbonate cover/ clear glass fixed with SS screws controlled with potted CVCC type, BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 4 KV minimum in circuit and 10 KV outside the driver but inside the fixture with IP-66, Class-1 protection for LED and control gear compartments with high power LED chips of rating 2.5 to 3 watt (maximum) with colour temperature 5700 K (max) and with secondary optics modular lenses provided to minimize glare and for better distribution of light suitable for voltage band 170 volts to 270 volts, power factor 0.95 (minimum) having efficacy 100 lumens/ watt, complete all as specified and directed.
S&F street light bracket made out of 25mm dia GI light grade tubing 1.5 metre long and bend to shape at 120º angle, at the middle from vertical, fixed with clamps, nuts and bolts, washers on pole, complete all as specified and directed. Note:- Clamps, nuts, bolts and washers will be measured and paid separately.
S&F junction box for street/ security light made out of polycarbonate with glass fibre reinforced and size should not less than 205mm x 255mm x 112mm, IP 66 suitable for upto 25 Sqmm cable with cable terminal plate with and including MCB SPN 10 Amps, C curve-01 No., necessary fixing accessories i.e. clamps nuts and bolts, complete all as specified and directed.
S&F astronomical digital timer switch for switching on/ off lights according to rising/setting of the sun with combination function for creating switching program in which devices are switched according to astronomical time and/or fixed preset time, current capacity 16A, weekly program with 1 change over (1 CO), total 28 programs min complete in powder coated CRCA sheet enclosure of suitable thickness with and including MCB TPN 32 Amps min, 3 pole contractor 32 Amps and MCB for manual switching of lights to override timer, fixing arrangement i.e. DIN rail complete with necessary porcelain insulator for incoming and outgoing cable connections with required clamp duly painted to fix on pole, complete all as specified and directed.
M&L MS work as in cross arms, bracing, supports, clamps, anti-climbing device and back plates fabricated from structural steel section including nuts, bolts, washers, cutting, welding, bending, cold or hot, drilling holes, grinding or bolt in any shape or size including application of two coats of aluminium paint over one coat of red oxide primer, complete all as specified and directed.
S&F galvanised pipe light grade 40mm bore for passing of cable fixed to poles/ walls/ laid under floor complete with and including fittings as required, complete all as specified and directed.
M&L for boring hole under the road/ pavement/ hard standing with the help of trenchless technology using ultra sound technique and necessary machine and including HDPE pipe 100mm of size not less than one metre below ground level, complete all as specified and directed.
Vee Bee Construction Co. (BID ID -3268542)
Elite Builders (BID ID -3268369)
WELWAYS ENGINEERS INDIA (BID ID -3265560)
M/s R.N Construction Co. (BID ID -3263935)
M/s Sahib and Company (BID ID -3268122)
M/S Vinod Kumar (BID ID -3268351)
Sachdeva Builders (BID ID -3268691)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.pdf
Tender Documents • 6.83 MB
BOQ.xls
BOQ • 0.58 MB
Tenderdocument_2.pdf
Tender Documents • 1.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .