Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹15.8 L+₹1.7 L (12.3%)Accepted-Finance 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | L2 | Accepted-Finance ok | |
| 3 | L3₹18.2 L+₹4.1 L (29.3%)Accepted-Finance | L3 | Accepted-Finance ok | |
| 4 | L4₹20.1 L+₹6.0 L (42.4%)Accepted-Finance A 6 MANDAWALI UNCHEPAR DELHI 110092 | SHAHDARA | DELHI | 110092 | L4 | Accepted-Finance ok | |
| 5 | L5₹30.3 L+₹16.2 L (114.8%)Accepted-Finance NOT FOUND | L5 | Accepted-Finance ok |
Tender Value
₹20.6 L
EMD Value
₹41,189
Closing Date
9 Mar 2026, 3:00 pmClosed
Executive Engineer (E) M 253 PWD
Executive Engineer (E) M 253 PWD, Delhi Sachivalaya, New Delhi
MOEI and Fans ic Street light drinking water pump sets for DA staff Quarters, Kalyanwas, Delhi. Replacement existing wornout Energy Meter panel and Earthing work
2026_PWD_288014_1
116/EE(E)/PWD M-253/2025-26
Open Tender
Electrical Works
Percentage
90 days
M 253 PWD, Delhi Sachivalaya, New Delhi
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
₹41,189
19 Mar 2026
2 Mar 2026
9 Mar 2026
2 Mar 2026
9 Mar 2026
2 Mar 2026
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority: Executive Engineer(E) PWD M-253
Name of Work:- MOEI & Fans i/c Street light drinking water pump sets for DA staff Quarters, Kalyanwas, Delhi. (SH:- Replacement existing wornout Energy Meter panel and Earthing work)
NIT No.:116/EE(E)/PWD M-253/2025-26 Estimated Cost:-20,59,450/-
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Sub Head Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 Supplying, installation, testing & commissioning of 16 Way Energy Meter panel of required size in single / muliple sagment as per space availability at site, suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system, dust & vermin proof duly fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates, cleaning & finishing with 7 tank process & powder coating in approved shade having 300 Amp capacity FP aluminium alloy bus bars of high conductivity, DMC/ SMC bus bar supports, Aluminium earth bar of size 25 mm x 5 mm at the rear of panel with 2 Nos. earth stud, connections from bus bar to switch gears with required size of Al. bus bars, in & out connections etc. including mounting of panel on MS Angle Iron frame fabricted with suitable size of MS angle iron duly painted and providing & Fixing following switch gears therein including dismantling of existing electrical panel after opening of in & out connections, making good the damages and cradit for the same under buy back etc. complete as required. (a) Incommer (i) 250A TPN MCCB 35kA - 1 No (ii) 3-Ph VAF meter with CT's-1 Set (iii) Indicating Light (RYB) with protection MCB's- 1 Set (b) Outgoing (i) Space for Energy Meter- 16 Nos. (ii) 63A DP MCB 10kA- 16 Nos. each 157960 374800 Excess(+) Full Conversion INR
2 Supplying, installation, testing & commissioning of 12 Way Energy Meter panel of required size in single / muliple sagment as per space availability at site, suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system, dust & vermin proof duly fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates, ccleaning & finishing with 7 tank process & powder coating in approved shade having 300 Amp capacity FP aluminium alloy bus bars of high conductivity, DMC/ SMC bus bar supports, Aluminium earth bar of size 25 mm x 5 mm at the rear of panel with 2 Nos. earth stud, connections from bus bar to switch gears with required size of Al. bus bars, in & out connections etc. including mounting of panel on MS Angle Iron frame fabricted with suitable size of MS angle iron duly painted and providing & Fixing following switch gears therein including dismantling of existing electrical panel after opening of in & out connections, making good the damages and cradit for the same under buy back etc. complete as required. (a) Incommer (i) 250A TPN MCCB 35kA - 1 No (ii) 3-Ph VAF meter with CT's-1 Set (iii) Indicating Light (RYB) with protection MCB's- 1 Set (b) Outgoing (i) Space for Energy Meter- 12 Nos. (ii) 63A DP MCB 10kA- 12 Nos. each 134666 374800 Excess(+) Full Conversion INR
3 Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. each 7698 374800 Excess(+) Full Conversion INR
4 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. METER 755 374800 Excess(+) Full Conversion INR
5 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. METER 374800 Excess(+) Full Conversion INR
6 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire METER 489 374800 Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.07 MB
BOQ_381887.xls
BOQ • 0.31 MB
cor116.pdf
PDF • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .