Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹45.1 L+₹13.3 L (39.6%)Accepted-AOC AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | ₹45.1 L+₹13.3 L (39.6%) Quoted ₹47.0 L | L2 | Accepted-AOC Lowest |
| 2 | L1₹33.7 LRejected-Finance 622 A STREET NO 3 FIRST FLOOR SHAKTI NAGAR BATHINDA 151001 PUNJAB | BATHINDA | PUNJAB | 151001 | ₹33.7 L | L1 | Rejected-Finance Rejected. Being Non Bonafide |
| 3 | L3₹50.2 L+₹16.5 L (49.1%)Rejected-Finance | ₹50.2 L+₹16.5 L (49.1%) | L3 | Rejected-Finance Other than Lowest |
| 4 | L4₹51.0 L+₹17.3 L (51.2%)Rejected-Finance | ₹51.0 L+₹17.3 L (51.2%) | L4 | Rejected-Finance Other than Lowest |
| 5 | L5₹51.3 L+₹17.6 L (52.2%)Rejected-Finance NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | ₹51.3 L+₹17.6 L (52.2%) | L5 | Rejected-Finance Other than Lowest |
| Sl No | Description | Qty | Unit | siddharthenterprises L2 | M/S GURBACHAN SINGH L5 | AAR KAY BEE ENTERPRISES L8 | KAMAL AGGARWAL L4 | NEW GURBINDER INDUSTRIES L10 | M/s Sahib and Company L7 | N S ENGINEERS L9 | PRATHAM TRADERS L6 | Truly Technos LLP L1 | PARGATI TOWER CORPORATION L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SUBMERSIBLE PUMPS/ SEWAGE PUMPS | |||||||||||||
| 2.00Disconnecting the three phase power supply system from the starter of panel board and taking out defective submersible pump motor set 3 phase along with taking out / removing of column pipes and cable carefully and carryout with transporting to work shop for repairing purposed, after repairing/ rewinding of the submersible pump motor set, jointing of cableing work and re-assembling the pump motor sytem complete and relowering in the same position of well with the help of jointing / fixing of column pipe, cable and including providing of suitable size / type of rubber joint gasket along with replacement of defected nut & bolt etc after making submersible cabling joint connection and connected with three phase power supply starter system including checking and testing of fault and rectification of fault from existing starter system complete and testing the pump motor set on load complete all as specified & directed for the following capacity/rating :- | |||||||||||||
| 2.01 | 10 hp | 2 | Each Job | 4,900 ₹9,800 | 5,100 ₹10,200 | 5,000 ₹10,000 | 4,850 ₹9,700 | 4,980 ₹9,960 | 5,000 ₹10,000 | 4,800 ₹9,600 Lowest | 4,900 ₹9,800 | 6,000 ₹12,000 | 4,900 ₹9,800 |
| 2.02 | 15 hp | 2 | Each Job | 5,100 ₹10,200 | 5,250 ₹10,500 | 6,500 ₹13,000 | 5,200 ₹10,400 | 5,290 ₹10,580 | 5,000 ₹10,000 Lowest | 5,000 ₹10,000 Lowest | 5,100 ₹10,200 | 6,400 ₹12,800 | 5,000 ₹10,000 Lowest |
| 2.03 | 20 hp - 22 hp | 3 | Each Job | 5,400 ₹16,200 | 5,440 ₹16,320 | 6,000 ₹18,000 | 5,450 ₹16,350 | 5,500 ₹16,500 | 5,000 ₹15,000 Lowest | 5,350 ₹16,050 | 5,400 ₹16,200 | 6,700 ₹20,100 | 5,350 ₹16,050 |
| 2.04 | 25 hp - 30 hp | 4 | Each Job | 5,900 ₹23,600 | 5,850 ₹23,400 | 6,200 ₹24,800 | 5,900 ₹23,600 | 5,990 ₹23,960 | 5,000 ₹20,000 Lowest | 5,850 ₹23,400 | 5,900 ₹23,600 | 6,900 ₹27,600 | 5,885 ₹23,540 |
| 2.05 | 41 hp | 2 | Each Job | 7,200 ₹14,400 | 7,800 ₹15,600 | 7,000 ₹14,000 Lowest | 7,600 ₹15,200 | 7,800 ₹15,600 | 7,000 ₹14,000 Lowest | 7,550 ₹15,100 | 7,600 ₹15,200 | 7,200 ₹14,400 | 7,510 ₹15,020 |
| 2.06 | 50 hp | 2 | Each Job | 7,200 ₹14,400 Lowest | 8,450 ₹16,900 | 9,000 ₹18,000 | 8,500 ₹17,000 | 8,490 ₹16,980 | 8,000 ₹16,000 | 9,000 ₹18,000 | 8,600 ₹17,200 | 8,400 ₹16,800 | 8,490 ₹16,980 |
| 2.07NOTE:- Replacement of unserviceable items/parts shall be measured & Paid for separately under respective items of BOQ. | |||||||||||||
| 3.00Opening/ dismantling and taking out old unserviceable burnt out winding matrerial/ defected parts from the existing submersible electric motor system of suitable capacity including providing re-winding materials with water proof copper insulated wire all as existing gauge / size / type including it connecting winding jointing material and including repair / replacement of other connected minor defected burnt out parts of motor and after reassembling it testing of system and carryout with transporting from work shop to site complete all as specified & directed for the following capacity/rating :- | |||||||||||||
Tender Value
Refer Docs
EMD Value
₹97,220
Closing Date
9 Jun 2025, 6:00 pmClosed
Sachin Kumar IDSE EE GE AF Adampur
Military Engineer Services AF Stn Adampur 144103
REPAIR/ MAINTENANCE AND REPLACEMENT OF SUBMERSIBLE PUMPS/ SEWAGE PUMPS AND DEVELOPMENT OF BOREWELL AND OTHER CONNECTED WORKS AND REPAIR/ MAINTENANCE OF WATER SUPPLY INSTALLATIONS INCLUDING CLEANING TANKS SUMPS AND MISC E/M WORKS AT AF STN ADAMPUR
2025_MES_709008_1
GE(AF)/ADM/T-29 OF 2025-26
Open Tender
Civil Works - Water Works
Item Rate
180 days
Under GE AF Adampur
As per NIT Documents
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹97,220
Yes
10 Sept 2025
19 May 2025
10 Jun 2025
20 May 2025
9 Jun 2025
3 Jun 2025
20 May 2025 - 2 Jun 2025
Amount
SUBMERSIBLE PUMPS/ SEWAGE PUMPS
Disconnecting the three phase power supply system from the starter of panel board and taking out defective submersible pump motor set 3 phase along with taking out / removing of column pipes and cable carefully and carryout with transporting to work shop for repairing purposed, after repairing/ rewinding of the submersible pump motor set, jointing of cableing work and re-assembling the pump motor sytem complete and relowering in the same position of well with the help of jointing / fixing of column pipe, cable and including providing of suitable size / type of rubber joint gasket along with replacement of defected nut & bolt etc after making submersible cabling joint connection and connected with three phase power supply starter system including checking and testing of fault and rectification of fault from existing starter system complete and testing the pump motor set on load complete all as specified & directed for the following capacity/rating :-
NOTE:- Replacement of unserviceable items/parts shall be measured & Paid for separately under respective items of BOQ.
Opening/ dismantling and taking out old unserviceable burnt out winding matrerial/ defected parts from the existing submersible electric motor system of suitable capacity including providing re-winding materials with water proof copper insulated wire all as existing gauge / size / type including it connecting winding jointing material and including repair / replacement of other connected minor defected burnt out parts of motor and after reassembling it testing of system and carryout with transporting from work shop to site complete all as specified & directed for the following capacity/rating :-
10 hp 3 phase 415 Volt
15 hp, 3 phase,415 Volt
20 hp - 22 hp, 3 phase, 415 Volt
25 hp-30 hp, 3 phase, 415 Volt
41 hp, 3 phase, 415 Volt
50 hp, 3 phase, 415 Volt
NOTE:- Replacement of unserviceable items/parts shall be measured & Paid for separately under respective items of BoQ.
Replacement of unserviceable spares parts with new parts as per existing sample/size/ make for the existing pumps/ motors complete for the following: -
Thrust plate with thrust bearing suitable using for 10/15hp 3 phase submersible pump motor system.
Thrust plate with thrust bearing suitable using for 20/22hp 3 phase submersible pump motor system.
Thrust plate with thrust bearing suitable using for 25/30hp 3 phase submersible pump motor system.
Thrust plate with thrust bearing suitable using for 41/50hp 3 phase submersible pump motor system.
Bush suitable using for 10hp / 15hp 3 phase submersible pump motor system.
Bush suitable using for 20hp/ 22hp 3 phase submersible pump motor system.
Bush suitable using for 25hp / 30hp 3 phase submersible pump motor system.
Bush suitable using for 41hp / 50hp 3 phase submersible pump motor system.
SS Sleeve suitable using for 10/15hp 3 phase submersible pump motor system.
SS Sleeve suitable using for 20/22hp 3 phase submersible pump motor system.
SS Sleeve suitable using for 25/30hp 3 phase submersible pump motor system.
SS Sleeve suitable using for 41 / 50hp 3 phase submersible pump motor system.
Neck ring suitable using for 10/15hp 3 phase submersible pump motor system.
Neck ring suitable using for 20/22hp 3 phase submersible pump motor system.
Neck ring suitable using for 25/30hp 3 phase submersible pump motor system.
Neck ring suitable using for 41/50hp 3 phase submersible pump motor system.
Impeller suitable using for 10/15 hp 3 phase submersible pump motor system.
Impellersuitable using for 20/22 hp 3 phase submersible pump motor system.
Impeller suitable using for 25/30 hp 3 phase submersible pump motor system.
Impeller suitable using for 41/50 hp 3 phase submersible pump motor system.
SS Shaft suitable using for 10/15 hp 3 phase submersible pump motor system.
SS Shaft suitable using for 20/22 hp 3 phase submersible pump motor system.
SS Shaft suitable using for 25/30 hp 3 phase submersible pump motor system.
SS Shaft suitable using for 41/50 hp 3 phase submersible pump motor system.
Disconnecting the three phase power supply system from the starter of panel board and taking out defective centrifugal type pump motor set of capacity 3hp to 5hp 3 phase carefully and carry out with transporting to work shop for repairing / rewinding purposed and taking out the burnt out winding from motor and rewinding with new one super enameled copper wire of existing size / gauge including provding with, insulation , varnishing, hardner etc material after re-assembling the centrifugal pump motor set complete and refixing in the same position of system and including providing of suitable size / type of of defected nut & bolt etc and making cabling connection with three phase power supply starter system including checking and testing of fault and rectification of fault from existing starter complete and testing the pump motor set on load complete as specified & directed. NOTE :- Replacement of unserviceable items/parts shall be measured & Paid for separately under respective items of BOQ.
Disconnecting the three phase power supply system from the starter of panel board and taking out defective centrifugal type pump motor set of capacity 7.5hp to 10hp 3 phase carefully and carry out with transporting to work shop for repairing/ rewinding purposed and taking out the burnt out winding from motor and rewinding with new one super enameled copper wire of existing size / gauge including provding with, insulation , varnishing, hardner etc material after re-assembling the centrifugal pump motor set complete and refixing in the same position of system and including providing of suitable size / type of of defected nut & bolt etc and making cabling connection with three phase power supply starter system including checking and testing of fault and rectification of fault from existing starter complete and testing the pump motor set on load complete as specified & directed. NOTE :- Replacement of unserviceable items/parts shall be measured & Paid for separately under respective items of BOQ.
Disconnecting the three phase power supply system from the starter of panel board and taking out defective centrifugal type pump motor set of capacity 20hp to 30hp 3 phase carefully and carry out with transporting to work shop for repairing / rewinding purposed and taking out the burnt out winding from motor and rewinding with new one super enameled copper wire of existing size / gauge including provding with, insulation , varnishing, hardner etc material after re-assembling the centrifugal pump motor set complete and refixing in the same position of system and including providing of suitable size / type of of defected nut & bolt etc and making cabling connection with three phase power supply starter system including checking and testing of fault and rectification of fault from existing starter complete and testing the pump motor set on load complete as specified & directed. NOTE:- Replacement of unserviceable items/parts shall be measured & Paid for separately under respective items of BoQ.
Disconnecting the three phase power supply system from the starter of panel board and taking out defective centrifugal type pump motor set of capacity 40hp to 50hp 3 phase carefully and carry out with transporting to work shop for repairing / rewinding purposed and taking out the burnt out winding from motor and rewinding with new one super enameled copper wire of existing size / gauge including provding with, insulation , varnishing, hardner etc material after re-assembling the centrifugal pump motor set complete and refixing in the same position of system and including providing of suitable size / type of of defected nut & bolt etc and making cabling connection with three phase power supply starter system including checking and testing of fault and rectification of fault from existing starter complete and testing the pump motor set on load complete as specified & directed. NOTE :- Replacement of unserviceable items/parts shall be measured & Paid for separately under respective items of BOQ.
Replacement of unserviceable spare parts with new parts as per existing sample/size/make for the existing motors/ pumps complete for the following :-
Ball bearing suitable for 3 hp/ 10 hp pump/motor
Ball bearing suitable for 20 hp/ 30 hp pump/motor
Ball bearing suitable for 40 hp/ 50 hp pump/motor
Coupling for 3.0 hp /10 hp pump/motor
Coupling for 20 hp /30 hp pump/motor
Coupling for 40 hp /50 hp pump/motor
Impeller suitable for 7.5 hp/10 hp pump/motor
Impeller suitable for 20 hp/30 hp pump/motor
Impeller suitable for 40 hp/50 hp pump/motor
M&L for Servicing of fire pump driven horizontal centrifugal pump set of capacity 49 Kw /65 hp, RPM-2000, 4 cylinder, type- 4R, rating 130-3046, head 70 metre, discharge 137 Cubic/ hour and size 125x 80mm including replacement of engine oil, fuel filtert, air filter and oil filter to the entire satisfaction of Engineer-in-Charge , complete NOTE :- Replacement of unserviceable items/parts shall be measured & Paid for separately under respective items of BOQ.
Replacement of unserviceable spare parts with new parts as per existing sample/ size/ make for the existing diesel pumps complete, for the following:
Engine oil servo premium 20W/40
Diesel and lubricant oil fiter kit complete set with all accessories of capacity 62.5 KVA
Fuel pipe pump
Fuel filter
Air filter
Opening up stuffing box of cast iron sluice valve in position and replacement of gland packing, nuts, bolts and washer etc complete for the following size :-
80 mm bore
100 mm bore
150mm bore
200mm bore
S&F, Maintnance free battery with initially charged 12 volt , 150 AH with 24 months warrenty IN REPLACEMENT complete all as specified and directed.
S&F, DOL motor starter in sheet steel enclosure 3 phase 415 V 50 HZ relay max range 9 Amp to 15 Amp, Max 15 Amp load, MN16 DOL type starter, IN REPLACEMENT, complete all as specified and directed. MAKE:- L&T Cat part No-SS94351 or equivalent as described in Appendix 'B'.
S&F, DOL motor starter in sheet steel enclosure 3 phase 415 V 50 HZ relay max range 20 Amp to 33 Amp, Max 15 Amp load, MN32 DOL type starter, IN REPLACEMENT, complete all as specified and directed. MAKE:- L&T Cat part No-SS94353 or equivalent as described in Appendix 'B'.
S&F, Fully automatic star delta motor starter in sheet steel enclosure 3 phase 415 V 50 HZ relay max range 20 Amp to 33 Amp, Max 63 Amp load, MN32 FASD type starter, IN REPLACEMENT, complete all as specified and directed. MAKE:- L&T Cat part No-SS94366 or equivalent as described in Appendix 'B'.
S&F, Fully automatic star delta motor starter in sheet steel enclosure 3 phase 415 V 50 HZ relay max range 28 Amp to 42 Amp Max 100 Amp load , ML3F FASD type starter IN REPLACEMENT, complete all as specified and directed. MAKE:- L&T Cat part No-SS90730 complete or equivalent as described in Appendix 'B'.
Disconnecting the three phase power supply system from the starter of panel board and taking out defective burnt out non-clog centrifugal sewage pump electric motor form the foundation U/G sump carefully and carry out with transporting to work shop for repairing / rewinding purposed and taking out the burnt out winding from motor and rewinding with new one super enameled copper wire of existing size / gauge including providing with, insulation , varnishing, hardner etc material after re-assembling the centrifugal pump motor set complete and refixing in the same position of system and including providing of suitable size / type of defected nut & bolt etc and making cabling connection with three phase power supply starter system including checking and testing of fault and rectification of fault from existing starter complete and testing the pump motor set on load complete all as specified & directed for the following capacity/rating :-
2 hp, 3 phase
5hp, 3 phase
7.5/ 10 hp, 3 phase
20hp, 3 phase
30hp, 3 phase
Dismantling and taking out existing non-clog sewage / under ground pump set from foundation including disconnecting all connections and transporting the same to workshop for purposed repairing, taking out the burnt out defected pump parts like, overhauling including shaft metaling, welding and grinding the shaft and replacing of all worn out/defective parts of pumps and making it in properly serviceable condition and re-assembling at site including refixing & reconnecting the same on original position complete all as specified & directed for the following capacity/rating :-
2 hp, 3 phase
5 hp, 3 phase
7.5/ 10 hp, 3 phase
20hp, 3 phase
30hp, 3 phase
NOTE :- Replacement of unserviceable items/parts shall be measured & Paid for separately under respective items of BOQ.
Replacement of unserviceable items/parts with new items/parts as per existing sample size and make for the non clog sewage pumps as under: -
Ball bearing for 2 hp non - clog pumping set.
Ball bearing for 5 hp non - clog pumping set.
Ball bearing for 7.5/ 10 hp non - clog pumping set.
Ball bearing for 20 hp non - clog pumping set.
Mild steel coupling with nuts and bolts suitable for 2 hp non clog pumping set.
Mild steel coupling with nuts and bolts suitable for 5 hp non clog pumping set.
Mild steel coupling with nuts and bolts suitable for 7.5/ 10 hp non clog pumping set.
Mild steel coupling with nuts and bolts suitable for 20/30 hp non clog pumping set.
Disconnecting the power supply system and taking out defective burnt out mono block electric pump motor from the foundation carefully and carry out with transporting to work shop for repairing / rewinding of pump and motar purposed and taking out the burnt out winding from motor and rewinding with new one super enameled copper wire of existing size / guage including providing with, insulation , varnishing, hardner etc material including overhauling of shaft metaling grinding and replacing of worn out defected parts of pump set after re-assembling the monoblock pump & motor set complete and refixing in the same position of system and including providing of suitable size / type of defected nut & bolt etc and making cabling connection with power supply system complete and testing the pump motor set on load complete all as specified & directed for the following capacity/rating :-
NOTE :- The unit rate shall be include for minor spares parts such as bolts, nuts wahers, oil seal, gasket, oiling, greasing, fans etc as required seviceable for pump.
Disconnecting the three phase power supply from the LT panel and taking out submersible pump motor set of any capacity alongwith column pipe and submersible cable including providing of developing of bore well with the help of air compressor machine of rating pressure capacity upto 250 PSI / 550 cfm till the bore well found sand free clear water is obtained from the bore well and all the removed blocked from the stainers pipes including opened up to the bore well depth of upto 400 feet depth after cleaning and re-assembling all the column pipe and pump with motor duly fixed with submersible cable joint & replacement of all defective nuts, bolts, washers, gaskets, packings etc. & submersible cable, relowering the pump set alongwith column pipe and cable and making electrical connection complete.
NOTE FOR SERAL ITEM 2 to 22 :- Not withstanding with the provision of "Compensation for Delay' envisaged under condition 50 of IAFW-2249, General Conditions of Contracts, additional compensation @ Rs. 500/- day will be charged from contractor in case he fails to make the functional to the entire satisfaction of Engineer-in-Charge within 24 hour of receiving of complaint from the MES regarding non working above items.
S&F, PVC insulated and PVC sheathed three core submersible flat cable multi stranded copper conductor wire 1100 volt grade suitable for operation of submersible pump motor set IN REPLACEMENT complete all as specified & directed for the following size:-
S&F, Power contactor, 3 pole, 415 volt AC ML2 type with NO & NC Aux contracts IN REPLACEMENT complete. MAKE :- L&T Cat part No-SS90701 or equivalent make as described in Appendix 'B'.
S&F, Power contactor, 3 pole, 415 volt AC ML3 type with NO&NC Aux contracts IN REPLACEMENT complete. MAKE:- L&T Cat part No-SS90721 or equivalent make as described in Appendix 'B'.
S&F, Power contactor, 3 pole, 415 volt AC ML4 type with NO&NC Aux contracts IN REPLACEMENT complete. MAKE:- L&T Cat part No-SS90910 or equivalent make as described in Appendix 'B'.
S&F, Directly operated over load relay of rating capacity 20 to 32 Amp IN REPLACEMENT complete. MAKE:- L&T Cat part No-SS9185900E0 or equivalent make as described in Appendix 'B'.
S&F, Directly operated over load relay of rating capacity 28 to 42 Amp IN REPLACEMENT complete. MAKE:- L&T Cat part No-SS9185900F0 or equivalent make as described in Appendix 'B'.
S&F, Directly operated over load relay of rating capacity 66 to 110 Amp IN REPLACEMENT complete. MAKE:- L&T Cat part No-SS94137 or equivalent make as described in Appendix 'B'.
S&F, Star Delta electronic timer 3 to 30 second rating, IN REPLACEMENT complete. MAKE:- L&T Cat part No-ST803280000 or equivalent make as described in Appendix 'B'.
S&F, Single phase preventor VSP 2/ VSP 3 type, IN REPLACEMENT complete.
S&F, GI column pipe, heavy duty as per existing sample including duly fixed flanges with hole for both ends and slot made for submersible cable complete all as specified & directed for the following size :-
50 mm bore, 10 feet long
80 mm bore, 10 feet long
100 mm bore, 10 feet long
S&F, MCCB TP 100 Amps, 415 Volts , 50 Hz , 16 KA adjustable thermal release range including all connections and testing IN REPAIRS, complate all as specified and directed.
S&F, MCCB TP 125 Amp, 415 Volts ,50 Hz , 16 KA adjustable thermal release range including all connections and testing IN REPAIRS, complate all as specified and directed.
S&F, MCCB TP 160 Amp, 415 Volts ,50 Hz , 36 KA adjustable thermal release range including all connections and testing IN REPAIRS, complate all as specified and directed
S&F, Digital Amp meter 0-200 amp, 3phase for existing panel, IN REPAIRS complete all as specied and directed.
S&F, Digital volt meter 0-500 Volts, 3phase for existing panel, IN REPAIRS complete all as specied and directed.
S&F, Indicating pilot lamp complete with base element with and lamp 240 V AC 50 C/s and connecting up IN REPLACEMENT complete all as specied and directed
M&L for including T&P for drilling of borewell to a depth of 100 metre below natural ground level including making arrangement of water, suitable for inserting 170mm PVC housing pipe using manual boring method/ rotary type drilling machine in any alluvial strata complete development of borewell 170mm housing pipe, 2 HP submersible Pump, suitable size motor starter etc in replacement complete all as specified and directed.
M&L for Earthing IN REPLACEMENT complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32x6 mm (upto the cross arms) by means of GI bolts/nuts/washers, protected by 40 mm bore GI medium grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh, factory made PCC earthing pit chamber & cover including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I. NOTE:- (i) Factory made PCC pit chamber shall be provided at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
WATER SUPPLY INSTALLATION
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for taxi track,PCC path / road / laying for pipe line etc. not exceeding 10 sqm on plan and getting out complete, all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, after the pipes have been laid and tested complete, all as specified.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
NOTES APPLICABLE TO SERIAL ITEM 42 TO 44: (a) Excavation work shall be carried out manually only. (b) LT/HT cable, water supply/ sewage/telephone lines, if any, get damaged during excavation & earthwork, demolition of PCC shall be repaired by the contractor immediately as per existing specifications to the entire satisfaction of Engineer-in-Charge.
M&L for Cleaning of RCC over head tank draining out water / sludge from tank, removing all scales, dirt , algea and other growths from the floor, roof and from mouths of circulating pipes by rubbing with the wire brushes and high pressure cleaning method with rotary sets with approved detergent and sucking out all dirty water by vacuum cleaner, disinfecting the over head tanks with approved chemical solution for making surface bacteria free and finaly cleaning with fresh water to the satisfaction of Engineer-in-Charge including painting MS plate manhole covers suction pipe rugs etc with anti corrosive paint and writing outside tank as ''TANK CLEANED ON'' and capacity on black painted surface including removing all dirt outside MD land complete of following capacity and staging: -
10000 gallon staging up to 15 metre height.
15000 gallon staging up to 15 metre height.
20000 gallon staging up to 20 metre height.
150000 gallon staging up to 20 metre height.
25000 gallon staging up to 25 metre height.
50000 gallon staging up to 25 metre height.
150000 gallon staging up to 25 metre height.
Dewatering and cleaning of sewage well / drainge water well any type any shape including removing of durty muddy / sewage / drainage water along with unwanted nonperishable items i.e polythene bags, PVC scrap, PVC bottles, shells, gum boots, wooden pieces and other floating materials etc and including removing complete wet type sludge formate / wet muddy formate from the inside of under ground well / tank and also connected entrance chamber area & hole area of well any type / size / depth and clean up to the last bottom level of well complete with all respect and disposal out / carrying out by manually or mechenically system to the wet sludge / muddy formate along with all type off floating material burried / carry out outside MD land complete for under ground well sump of size:-
6.5 dia and 6 metre depth.
1.5 dia and 5 metre depth.
NOTE APPLICABLE FOR SERIAL ITEM 45 & 46:- (i) All required T&P for cleaning of RCC over head tank / under ground sewage, water sump and other safety equipment required for working of manpower shall be arrange by contractor under own arrangement without any extra cost to the Dept. (ii) The contractor shall soley responsible for any mishap,accident and other mishappening to workmen during working time and setting all claims of workmen as per the labour commissioner or court law and the rates quoted by the contractor shall deemed to be included for this aspect and nothing extra shall be payble on this account. (iii) The contractor provided sufficient more nos labour for cleaning of overhead tank under ground sump within the given time period by depaetment. No such type of delay reason are not accepted due to shortage of labour for cleaning of over head tank / under ground sump.
M&L for Chemical analysis including micro biological examination of water sample obtaining from bore well at pump house No-1 to 12 under GE (AF) Adampur. Collect the sample as per standard operating procedure from bore well as chemical and microbiological as per the IS specification. NOTE:- (i) The complete analysis report should be submitted within specific period. (ii) Bore well should be test by NABL approved lab as approved by GE.
S&F, Cast Iron butter fly valve wafer Type, class PN 25 with S.S-304 disc, body S.G iron, lever operated, Nitrile / EPDM rubber lining seat test pressure 2.5 Mpa, ISI marked , IN REPLACEMENT complete. of size: -
80mm dia
150mm dia
S&F, Wire antina with lead system suitable for signal operation of scada automation slave panel IN REPLACEMENT complete all as specified and directed.
S&F, Buzzer system with base electrical connector suitable for showing to fault level of scada automation slave panel IN REPLACEMENT complete all as specified and directed.
S&F, Presuure switch 0-10 kg/Sq.cm with accessories and calibrate with PLC (Programmable Logic Controller) IN REPLACEMENT complete all as specified and directed.
S&F, PLC (Programmable Logic Controller) with connected power supply system with controller lead complete as per existing model for automation slave panel comprising of main controller, including testing complete all as specified and directed.
S&F, HMI-GT 21 series 3.8'' TFT monochrome, TFT LCD with 32 grey scale 24 vdc built in, RS232, RS-485 USB port interference for PLC based panel IN REPLACEMENT, including re-programming & testing complete all as specified and directed..
NOTES APPLICABLE TO SERIAL ITEM 53 TO 54. Downloading and uploading of the PLC programs carried out only in the presence of Recktronic device & system / Automation and Tech solutions or Integrated control system as approved by GE.
S&F, Relay pin type 4C/O IN REPLACEMENT complete, as per existing model & compatibility of size: -
220-240 volt AC
24 volt DC
S&F, wireless communication modem with for information to slave panel as well as SCADA as per exiting sample / size IN REPLACEMENT complete all as specified and directed.
S&F, LED indicating lamp of colour red / green / yellow as per exiting sample / size IN REPLACEMENT complete all as specified and directed.
S&F, LED indicator with push button red / green type -240 Volt Ac as per exiting sample / size IN REPLACEMENT complete all as specified and directed.
S&F, Rust proof maintenance free magnetic float switch / water level sensor as per exiting sample / size IN REPLACEMENT complete all as specified and directed.
S&F, Hand wheel for actuator suitable for of size 150mm bore butterfly valve as per exiting sample / size IN REPLACEMENT complete all as specified and directed.
S&F, SMPS unit suitable for out put 24 volt DC and input 230 volt AC of rating 3 Amp as per exiting sample/ size IN REPLACEMENT complete all as specified and directed.
S&F, Motor actuated valve (Direct) complete single phase motor actated with gear box valve set with disc material of CI with nylon coating, hand wheel for manual operation, pressure rating of 10 kg/sq cm and having 02 nos limit switches for open / closed condition and capability of accepting 4-20 amp input complete set. of following size: -
80/100 mm bore
150 mm bore
Defected/ burn out /unsafe internal control wiring and connection for automation slave panel installed at pump house and including using by FRLSH PVC insulated electric wire with copper conductor wiring having of single core of size 0.5 - 1.0 Sq. mm sub main wiring as properly electrical connection for smooth controlling panel of scada system including resetting of system complete and testing IN REPLACEMENT complete. MAKE:- Recktronic device & system / Automation and Tech solutions or Integrated control system as approved by GE.
S&F, 5 pair of 0.5 mm dia armoured copper cable suitable for sensoring with suitable size of PVC conduit pipe as per exiting sample/ size duly fixed on wall of over head tank IN REPLACEMENT complete all as specified and directed.
M&L for PVC sheathed PVC insulated copper armoured cable IN REPLACEMENT complete all as specified of following size: -
1.5 sq.mm 2 core
1.5 sq.mm 4 core
1.5 sq.mm 6 core
M&L for Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 25 mm x 4 mm GI strip earthing lead complete all as shown in electrical plate No. 3 and as specified in Particular Specifications of contract, IN REPAIR.
NOTES: - (i) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate. (b) Factoy fabricated precast PCC pit & cover shall be fixed at least 500 mm away from earth pit. (iv) Earth resistance should not be less than 3Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt.
S&F, Galvanised iron strip 25 mm x 4 mm with new saddles and fixing screws on porcelain insulators for roof conductors and down conductors above ground level and in trenches fixed IN REPLACEMENT complete all as specified and directed.
S&F, Air termination single pointed copper rod of dia 12mm and 300 mm long including making connection to earthing conductor IN REPLACEMENT complete all as specified and directed.
S&F, GI pipe 25mm bore light grade (ISI Marked) cut piece of 1.0 metre - 1.5 metre length, fixed vertically with bottom end embedded in and including cast in situ PCC (1:2:4) block of size 20cmX 20cmX 15cm including use and waste necessary fair finish form work and other end (at top) fixed to air termination rod with necessary nut and bolts etc as required IN REPLACEMENT complete all as specified and directed.
S&F rigid non metallic heavy duty Gr-B PVC conduit of 30/32mm bore inclusive all standard fittings, for passing of communication cables etc. under plinth/ floor or fixed to wall with necessary fixing arrangement complete all as specified and directed.
M&L for replacing new LED obstruction light as per existing make/ power fixed on top of OHT with necessary fixing arrangement and providing PVC insulated three core flexible copper cable and including metallic conduit 20mm dia fixed on surface of water tank upto control MCB enclosure with MCB SPN 06 AMP IN REPLACEMENT complete all as specified and directed.
M&L for Rectification of leakage in CI/DI pipe line making it leak proof to the entire satisfaction of Engineer-in-Charge by filling jointing material etc.including necessary excavation & earth work complete CI/DI pipe of size: -
50-100 mm bore
150-200 mm bore
S&F, CI foot valve, flanged type, ISI marked, with flanged joint & jointing material, IN REPLACEMENT complete, all as specified suitable for CI/DI pipe of size as under: -
40-65 mm bore
80 mm bore
100 mm bore
Note : Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
siddharthenterprises (BID ID -3316752)
PARGATI TOWER CORPORATION (BID ID -3316881)
KAMAL AGGARWAL (BID ID -3317488)
M/S GURBACHAN SINGH (BID ID -3317229)
PRATHAM TRADERS (BID ID -3317219)
M/s Sahib and Company (BID ID -3317922)
AAR KAY BEE ENTERPRISES (BID ID -3317387)
N S ENGINEERS (BID ID -3316244)
NEW GURBINDER INDUSTRIES (BID ID -3317670)
Bidder Name
Truly Technos LLP
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .