DAY TO DAY MAINTENANCE OF E/M SERVICES AND ALLIED WORKS OF MD ACCN IN AGE E/S UNDER GE (WEST) JABALPUR
2026_MES_790524_1
9098/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Jabalpur
₹80,000
22 Sept 2026
22 Sept 2026
20 Oct 2026
23 Sept 2026
13 Oct 2026
6 Oct 2026
23 Sept 2026 - 1 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified & directed by Engineer-in-Charge. | 1,220 | Per Point | - | - |
| - | Taking down carefully main switches / distribution boards complete of any size and refixing after repair and MCBs SP /SPN or Cut out of any size all as required and directed at site | 350 | Each | - | - |
| - | Repair the sub main wiring with detecting the fault and repair the point after replace the u/s wire of 2.5 sqmm copper conductor cable drawing into pvc conduit and jointing properly including taping with ISI mark insulation tape all as required and directed at site.Make of wire:Finolex/RR/KEI | 150 | RM | - | - |
| - | Repair the sub main wiring with detecting the fault and repair the point after replace the u/s wire of 4 sqmm copper conductor cable drawing into pvc conduit and jointing properly including taping with ISI mark insulation tape all as required and directed at site | 120 | RM | - | - |
| - | Repair the sub main wiring with detecting the fault and repair the point after replace the u/s wire of 6.0 sqmm copper conductor cable drawing into pvc conduit and jointing properly including taping with ISI mark insulation tape all as required and directed at site | 30 | RM | - | - |
| - | Repair the sub main wiring with detecting the fault and repair the point after replace the u/s wire of 10.0 sqmm copper conductor cable drawing into pvc conduit and jointing properly including taping with ISI mark insulation tape all as required and directed at site | 20 | RM | - | - |
| - | Repair to point wiring with taking out the fault removing the u/s / brunt wire and repair with repalacemnt of wire jointing properly with connector and making the point serviceable (replacemnt of wire not more then 1.5 mtrs, junction box cover / connection of point is included in type cost of repair) and making the point serviceable all as required and directed at site | 450 | Each | - | - |
| - | M& L for comprehensive maintenance and repair to point wirring with taking out fault in the wiring and repair to the point wring and making the point wiring serviceable including following works (a) Checking proper working of wiring light or fan point (b) Checking of socket point/switch /holder point including replacement of unseviceable part (c) Replacement of unserviceable batten holder/ tube light/lamps/ ballast/bipin holder /fittings (d) Cleaning of tube light fitting ( e) Note : 1.Contractor has to depute two electricians including one helper with each electrician daily who will report to JE E/M in mes YARD under AGE E/M E/S. 2 Unserviceable parts to be measured & paid seperately under relevant item of Sch A. All Tools & Plants and ladder provided to electrician at site by The contractor. | 1,250 | Each job | - | - |
| - | Taking down the old unsv sub main wiring of any size all as required and directed at site | 650 | RM | - | - |
| - | M/L for Sub Main Wiring two single core PVC insulated cable of size 4.0 Sqmm multistranded copper conductor two run drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and one run of 4.0 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :-Two Nos of 4.0 Sqmm Wire and one No of 4.0 Sqmm Earth wire in One RM length Measured as one unit length. | 450 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
9098GP.pdf
Tender Documents • 0.41 MB
Tender9098SPPS.pdf
Tender Documents • 1.29 MB
SCH9098.pdf
Additional Documents • 0.09 MB
BOQ_886195.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .