Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.1 L+₹31,693 (4.06%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹8.4 L+₹64,605 (8.28%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹8.9 L+₹1.1 L (13.6%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹9.1 L+₹1.3 L (17.0%)Rejected-Finance GEETA COTTAGE NO 03 HOUSE NO 11 OPP CIVIL AIR PORT BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
28 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I P Niwaru
AGE I P Niwaru armu cantt jaipur
REPAIR AND MAINT TO LT CIRCUITS AND SWITCH GEARS AT NIWARU, JAIPUR MIL STN UNDER AGE (I) (P) NIWARU
2021_MES_464306_1
AGE(I)(P)/N-13 of 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE I P Niwaru
Class-E
6 documents required · 6 mandatory
₹500
Yes
AGE(I)(P) Niwaru
₹24,000
Yes
7 Oct 2021
31 Jul 2021
30 Aug 2021
31 Jul 2021
28 Aug 2021
14 Aug 2021
60 days
Amount
Excavation in trenches n.exc 1.5metre wide and n.exc 1.5 metre in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm in depth.
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point.
M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) laid flat abutting each other with width of protection being equal to length of brick. The gap between adajcent bricks shall not exceed 10 mm as directed by Engineer-in-Charge.
laying only Bricks for protection cover to under ground cable (retrieved undamaged old sub class 'B' bricks during excavation for laying of cable) with width of protection equal to length of brick laid flat abutting each other with width of protection being equal to length of brick. The gap between adajcent bricks shall not exceed 10 mm as directed by Engineer-in-Charge.
M & L Sand cushioning to PVC under ground cable with screened and washed sand (Tibba Sand) including punning gently (up to 23 cm depth ,8 cm below the cable and 15cm above the cable) all as specified and directed. Note: - Thickness after punning will be measured for payment.
Supply and Laying Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured, cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, under floors/ roads or on walls in repair and incl taking down of following sizes (make- Havells/Gloster/Polycab) :- Note : Earth work, excavation shall be measured & paid separately under respective item of Schedule.
(a) 6 Sqmm 2 Core
(b) 10 Sqmm 2 core
(c) 16 Sqmm, 4 core
(d) 25 Sqmm, 4 core
(e) 35 Sqmm, 3.5 core
(f) 50 Sqmm, 3.5 core
(g) 70 Sqmm, 3.5 core
Supply & fixing or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles / walls under road crossing etc of following sizes including dismantling & taking down existing pipe :-
(a) 80mm bore
(b) 50mm bore
M&L for drilling hole under road for laying of U/G cable through pipe of size up to 100 mm bore complete all as specified and directed at site.
M&L for repairing of LT panels incl welding of doors, fixing of hinges, brazing complete all as specified and directed by engineer in charge.
&L for synthetic enamel paint on old steel or iron painted surfaces of any description, over 10cm in width or girth,not otherwise all as per described, specified and direction of engineer in charge.
M & L for scraping, cleaning and preparation of old painted surface of LT steel tubular pole (9/11 meters long),steel fitting fixtures with clamps applying one coat of aluminium paint after preparation of steel surfaces and, making of strip of 30 cm width (black and white in alternate band) upto 1500 mm height from the bottom of the pole for indication of poles and writing the pole Nos with synthetic enamel paint, rewriting pole No by painter with enamel paint complete as specified and directed by EIC.
Supply and fix in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured XLPE aluminium conductor cable of size 120 Sqmm 3.5 core. (Note:- Item rate quoted including excavating/required T&P/Refixing & Refilling.)
All as item No. 13 above but for cable of size 95 Sqmm 3.5 core.
All as item No. 13 above but for cable of size 70 Sqmm 3.5 core.
All as item No. 13 above but for cable of size 50 Sqmm 3.5 core.
All as item No. 13 above but for cable of size 35 Sqmm 3.5 core.
All as item No. 13 above but for cable of size 25 Sqmm 4 core.
All as item No. 13 above but for cable of size 16 Sqmm 4 core.
M&L for MCCB, 4 pole, 36 KA in repair in existing panel/DB incl connection with necessary lugs, nut & bolts, washer etc. of the following sizes :-
upto 63 Amps
M&L for MCB, 4 pole, 'C' curve, 25 KA in repair in existing panel/DB incl connection with necessary lugs, nut & bolts, washer etc. of the following sizes :-
6 to 32 Amps
40 to 100 Amps
material and labour for taking out the existing panel after all connection to be disconnected and commissioning and testing to LT feeder piller after installation on suiatable size angle iron frame(height of bace should be min 450mm above ground) and angle frame should be fixed on PCC foundation and base of the foundation prepared by aggregate of 20mm dia size of ratio 1:2:4 type B1 and size of the base 1200x700x200mm thick ,panel should be grouted on the PCC by Nut bolt of size 5mm dia10 cm long 4 Nos including connection of earthing strip and cable by necessary joint of cable and earthing strip and replace the U/s lugs as per site requirement and directed by EIC.
Material & Labour for preparation of old painted surface of electrical panel inner and outer surface complete by scrubbing with iron brush and applying two coat synthetic enamel paint with spray machine complete.
(a) Lengh (0.5m to 1 m), Height(0.5m to 1m), Breadth(Up to 0.5 m)
(b) Lengh (0.5 m to 1 m), Height(1 m to 2 m), Breadth(Up to 0.5 m)
(c ) Lengh (1 m to 2 m), Height(1 m to 2m), Breadth(Up to 0.5 m)
Laying only Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured, cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, under floors/ roads or on walls of size up to 240 Sqmm any core. Note (i) Earth work, excavation shall be measured & paid separately under respective item of Schedule). (ii) LT Cablel will be issued under Sch ‘B’ free for Laing only.
All as item No. 24 above but for cable of size 185 Sqmm 3.5 core.
M/S STEADFAST ENTERPRISES
M/s Prakash Enterprises
S.R.Enterprises
AARTI ENTERPRISES
M/S M P SHARMA
SM CONSTRUCTION COMPANY
LAKSHMI ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .