Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.1 LAdmitted-Finance 00 KAMALWAGANJA ROAD NEAR HANUMAN MANDIR HARINAGAR SHIV PURAM PHASE 1 HALDWANI NAINITAL UTTARAKHAND 263139 | NAINITAL | UTTARAKHAND | 263139 | L1 | Admitted-Finance | ||
| 2 | L2₹7.8 L+₹72,250.16 (10.2%)Admitted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | L2 | Admitted-Finance |
Tender Value
₹8.4 L
EMD Value
₹16,733
Closing Date
17 Sept 2026, 1:00 pmClosed
SE TNC BHARATPUR
SE TNC BHARATPUR 220 KV GSS PREMISES RIICO AREA BHRATAPUR 321001
AUGMENTATION WORK AND OIL FILTERATION WORK OF 220 132 kV 160 MVA POWER TRANSFORMER AT 220 KV GSS RVPN CHHONKARWADA Dist BHARATPUR
2026_RRVPN_595761_1
TN-11/2026-27
Open Tender
Construction Works
Percentage
220 kV GSS CHONAKARWA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
RRVPNL COLLECTION ACCOUNT
₹16,733
Yes
BHARATPUR
23 Sept 2026
9 Sept 2026
17 Sept 2026
9 Sept 2026
17 Sept 2026
9 Sept 2026
14 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Laying of earth mesh with 25mm / 28mm dia M.S. Rod at a depth of 0.80 metre from top level of foundation, including excavation of trench of required depth and backfilling of the same, transportation of M.S. Rods from site store to location, welding of M.S. Rod to M.S. Rod along the length, at crossings and with earth electrodes as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 0.80 metre below top level of foundations (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN).(a) In case electricity is made available by RVPN without charges. i) Any soil, soft rock other than hard rock | 400 | Mtr | 35 | ₹14,000 |
| 2 | Laying of earthing risers of 50x6mm / 50x10mm / 50x12mm size M.S. Flat at a depth of 0.80 metre from top level of foundations, including excavation of trench of required depth and back filling of the same, transportation of M.S. Flat from site store to locations, preparation of risers, bending as per reqiurement (after heating if necessary), fixing on & belding / bolting of equipment / structure & peaks of structure, laying in the trench, welding to earth mesh of M.S. Rod as per drawing, including welding of extra length of M.S. Flat if required, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, painting of all surfaces of risers above ground level with red oxide and green paint, for the type of soil prevalent at 0.80 metre below top level of foundations (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN).(a) In case electricity is made available by RVPN without charges.i) Any soil, soft rock other than hard rock | 450 | Mtr | 39 | ₹17,550 |
| 3 | Placing / Driving of earth electrode of 25 / 28mm dia. M.S. Rod of length 3.30 metres (approx.) to a depth of 3.80 metres from the top level of foundations, including excavation of pit as required and back filling of the same, transportation of M.S. Rod from site store locations, cutting of M.S. Rod to desire length, preparation of one end as as spike if necessary, welding of earth electrode to earth mesh of M.S.Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 3.80 mtrs below top level of foundations (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN).(a) In case electricity is made available by RVPN without charges. i) Any soil, soft rock other than hard rock | 30 | Nos | 374 | ₹11,220 |
| 4 | STRINGING of 220KV, 132KV, 33KV & 11KV Bus Bar of ACSR & Tarantulla conductor including transportation of conductor, disc insulator & tension hardware from site store to location, laying & cutting required length of conductor, cleaning & assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available between the beams with specified sag and tension, also equilising sag and fitting spacers and spacer T-clamps for twin conductor for three phase of conductors in each sub-section.(Per jumper basis) i) Any Double Conductor | 9 | SECTION | 2,406 | ₹21,654 |
| 5 | JUMPERS of ACSR conductor (3 nos. Y-type) between bus to equipment or between equipment to equipment or between bus to bus, including transportation of conductor, disc insulators and hardware from site stores to locations, cleaning & assembly of disc insulators as required along with fitting of suspension hardware and erection as required length of conductor, making connections, fixing of spacers & spacer T-clampsas required, tightening of clamps / connectors, dressing etc., for three phases.(Per jumper basis) any condictor | 120 | EACH | 152 | ₹18,240 |
| 6 | Erection of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. ii) 220 KV CT / PT / CVT | 3 | Nos | 3,461 | ₹10,383 |
| 7 | Erection of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. iii) 132 KV CT/PT/CVT | 3 | Nos | 1,936 | ₹5,808 |
| 8 | Erection of Lightening Arrestor on already erected steel structure including transportation of Lightening Arrestor, clamps & connectors, surge counter etc from site store to locations, fabrication of base frame, fixing of terminal connectors, surge counter, tightening of nuts & bolts etc, complete in all respects. ii) 220 KV | 3 | Nos | 2,732 | ₹8,196 |
| 9 | Erection of Lightening Arrestor on already erected steel structure including transportation of Lightening Arrestor, clamps & connectors, surge counter etc from site store to locations, fabrication of base frame, fixing of terminal connectors, surge counter, tightening of nuts & bolts etc, complete in all respects. 132 KV | 3 | Nos | 1,946 | ₹5,838 |
| 10 | Erection of 220KV Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P I's contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI. a) Without Earth Blade a) Without Earth Blade | 3 | Nos | 6,021 | ₹18,063 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.37 MB
Tendernotice_2.pdf
PDF • 16.70 MB
BOQ_1056744.xls
BOQ • 0.27 MB
TN11NIB.pdf
Tender Documents • 2.35 MB
TN11BID.pdf
Additional Documents • 16.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .