| 1 | L1₹37.4 LAccepted-AOC GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹43.1 L+₹4.2 L (10.8%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹44.1 L+₹5.2 L (13.5%)Rejected-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹45.1 L+₹6.2 L (15.9%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹45.8 L+₹6.9 L (17.7%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
COMPREHENSIVE REPAIR MAINTENANCE OF LT ELECTRIC DISTRIBUTION LINES PANELS AND ALLIED WORKS AT BEG and CENTRE TB I DEPOT BN UNDER AGE EM I UNDER GE C KIRKEE
2021_MES_492996_1
8563/E8 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE CENTRAL KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
GE CENTRAL KIRKEE
₹90,000
Yes
2 Feb 2022
7 Dec 2021
10 Jan 2022
7 Dec 2021
4 Jan 2022
22 Dec 2021
7 Dec 2021 - 21 Dec 2021
60 days
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in soft loose soil. Complete all as specified nad as directed by Engineer in Charge.
All as per item No. 1 above but depth exceeding 1.5 m and not exceeding 3 m Complete all as specified nad as directed by Engineer in Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick. Complete all as specified nad as directed by Engineer in Charge.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. Complete all as specified nad as directed by Engineer in Charge.
PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc Complete all as specified nad as directed by Engineer in Charge.
PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work Complete all as specified nad as directed by Engineer in Charge.
M&L for sand for cousioning of UG cable/ at cable trenches inside substation bulding Complete all as specified nad as directed by Engineer in Charge.
M&L for brick protection with sub class 'B' brick for UG cable Complete all as specified nad as directed by Engineer in Charge.
Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismentling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit Complete all as specified nad as directed by Engineer in Charge.
Materisl and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm 2 core with required aluminium cable lugs, heat shrink joints, Colour code heat shrink sleeves at both cable ends all as specified and directed. Note: (i) Heat shrink joint 2 core/4 core will be measured and paid under appropriate item of this Schedule. (ii) Serviceable GI tubing obtained from item No-9 here-in-before for cable protection will be refixed/relaid, No extra measurement/payment will be made. (iii) GI tubing required new will be measured and paid separately under respective item of this schedule. (iv) Heat shrink sleeve of 25mm long on HS joint for colour indication will deemed to be included on the quoted rate, (v) Addl aluminium cable lugs require for jointing cable termination will deemed to be included in the quoted rate and no extra measurement/payment will be made.
All as per item No. 10 here-in-before but 10sqmm 2 core Complete all as specified nad as directed by Engineer in Charge.
All as per item No. 10 here-in-before but 16sqmm 2 core Complete all as specified nad as directed by Engineer in Charge.
All as per item No. 10 here-in-before but 10sqmm 4 core Complete all as specified nad as directed by Engineer in Charge.
All as per item No. 10 here-in-before but 16sqmm 4 core Complete all as specified nad as directed by Engineer in Charge.
All as per item No. 10 here-in-before but 25sqmm 3,5 core Complete all as specified nad as directed by Engineer in Charge.
All as per item No. 10 here-in-before but 50sqmm 3.5 core Complete all as specified nad as directed by Engineer in Charge.
All as per item No. 10 here-in-before but 70sqmm 3.5 core Complete all as specified nad as directed by Engineer in Charge.
All as per item No. 10 here-in-before but 95sqmm 3.5 core Complete all as specified nad as directed by Engineer in Charge.
All as per item No. 10 here-in-before but 120sqmm 3.5 core Complete all as specified nad as directed by Engineer in Charge.
All as per item No. 10 here-in-before but 300 0sqmm 3.5 core Complete all as specified nad as directed by Engineer in Charge.
Labour only for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board at existing places or carrying to other location, 1100 volts grade heavy duty cable with XLPE/PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size upto 25 sqmm 4 core obtained from item no-09 here-in-before with required aluminium cable lugs, heat shrink joints, Colour code heat shrink sleeves at cable ends Complete all as specified and as directed by Engineer in Charge. Note: . (i) Heat shrink joint 2 core/4 core will be measured and paid under appropriate item of this Sch as supply only. (ii) Serviceable GI tubing obtained from item No-8 here-in-before for cable protection will be refixed/relaid, No extra measurement/payment will be made. (iii) GI tubing required new will be measured and paid separately as supply only.
All as per item No. 21 here-in-before but 35 sqmm 3.5 core to 120 sqmm, 3.5 core Complete all as specified nad as directed by Engineer in Charge.
All as per item No. 21 here-in-before but 150 sqmm 3.5 core to 400 sqmm, 3.5 core Complete all as specified nad as directed by Engineer in Charge.
Dismentling taking out broken/worn out steel pole of 8.5 to 9.0 mtr long and kepping aside for refixing or carrying to store for credit Complete all as specified nad as directed by Engineer in Charge.
M&L for steel tubular swaged pole complete with cast iron base plate , finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410 SP-31 (9 mtr long) Complete all as specified nad as directed by Engineer in Charge.
Labour only for re-fixing of steel tubular swaged pole complete with cast iron base plate , painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type (9 mtr long) Complete all as specified nad as directed by Engineer in Charge.
Dismantling and taking down old/unsv cross arms, bracing, supports etc complete for reuse at site or carrying to store for sch of credit Complete all as specified nad as directed by Engineer in Charge.
Supply and fixing cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints Complete all as specified nad as directed by Engineer in Charge.
Dismantling and taking down old/unsv ACSR conductor any size complete for reuse at site or carrying to store for Sch of Credit Complete all as specified nad as directed by Engineer in Charge.
S&F ACSR conductor incl jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection Complete all as specified nad as directed by Engineer in Charge.
Dismantling and taking down old/unsv insulator of any type any size from pole/stay for reuse at site or carrying to store for sch of credit Complete all as specified nad as directed by Engineer in Charge.
S&F pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade Complete all as specified nad as directed by Engineer in Charge.
S&F shackle type,porcelian vitreous white, brown or green insulator including galvanised mild steel straps , washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade Complete all as specified nad as directed by Engineer in Charge.
S&F Loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm Complete all as specified nad as directed by Engineer in Charge.
M/L for Stay assy using 16mm dia galvanised rod complete all as shown in electrical plate No 1 of SSR Part I incl dismentling unsv one Complete all as specified nad as directed by Engineer in Charge. (Clamps, loop insulator, earth work, PCC measured separately)
S&F for stay wire using galvanised steel strand of 7/3.15mm complete with necessary binding incl dismentling taking down unserviceable Complete all as specified nad as directed by Engineer in Charge.
S&F cradle hexagonal /rectangular fabricated with galvanised steel wire not less than 4mm dia on pole incl dismentling taking out unsv cradle guard Complete all as specified nad as directed by Engineer in Charge.
S&F earth continuity wire using GI wire not less than 4mm dia on pole incl dismentling taking out unsv GI wire Complete all as specified nad as directed by Engineer in Charge.
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing lead of 25x4 mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with pit cover, funnel, wiremesh, 32 mm dia light grade GI tubing for protection of GI strip 25x4mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion Complete all as specified nad as directed by Engineer in Charge.
M&L for restraining of overhead ACSR conductor of any size of 4 wire on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P Complete all as specified nad as directed by Engineer in Charge.
M&L for restraining of ACSR conductor of any size of 2 wire on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P Complete all as specified nad as directed by Engineer in Charge.
M&L for restraining of GI Cradle guard hexagonal/rectangular of any size on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P Complete all as specified nad as directed by Engineer in Charge.
M&L for restraining of GI wire of any size on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P Complete all as specified nad as directed by Engineer in Charge.
Cutting/Trimming of tree branches arround 3.00 mtr distance from conductors of HT over head line of span up to 50 meters including removing of creepers etc frompoles Complete all as specified nad as directed by Engineer in Charge.
Cutting/Trimming of tree branches arround 3.00 mtr distance from conductors of LT over head line of span up to 40 meters including removing of creepers/vegitation etc from poles Complete all as specified nad as directed by Engineer in Charge.
Painting of steel pole any type up to 7.5 mtr height above ground level including cross arms,clamps,stay clamps etc with two coats of aluminium paint after surface preparation all as directed by Engr-In-Charge
Painting of steel pole any type up to 9.5 mtr height above ground level including cross arms,clamps,stay clamps etc with two coats of aluminium paint after surface preparation all as directed by Engr-In-Charge
Numbering of HT/LT poles serially with letter/number size width and height up to 40 mm in situ with black paint on white back ground Complete all as specified nad as directed by Engineer in Charge.
Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 10-16 sqmm, 4 core , make-Raychem, Cat No-EPKT0003 or equivelent of M-Seal/MS Seal/3M Complete all as specified nad as directed by Engineer in Charge.
Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 25-50 sqmm, 4 core, make-Raychem, Cat No-EPKT0019 or equivelent of M-Seal/MS Seal/3Maychem/M-Seal/MS Seal/3M Complete all as specified nad as directed by Engineer in Charge.
Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 70-150 sqmm, 4 core, make-Raychem, Cat No-EPKT0035 or equivelent of M-Seal/MS Seal/3M Complete all as specified nad as directed by Engineer in Charge.
Supply and fix Heat shrink joint indoor/outdoor LT 1100 volts grade 185-300 sqmm, 4 core, make-Raychem, Cat No-EPKT0051 or equivelent of M-Seal/MS Seal/3M Complete all as specified nad as directed by Engineer in Charge.
Supply and fix Heat shrink straight through joint LT 1100 volts grade 10-16 sqmm, 4 core, make-Raychem, Cat No-EPKJ0123 or equivelent of M-Seal/MS Seal/3M Complete all as specified nad as directed by Engineer in Charge.
Supply and fix Heat shrink straight through joint LT 1100 volts grade 25-50 sqmm, 4 core, make-Raychem, Cat No-EPKJ0130 or equivelent of M-Seal/MS Seal/3M Complete all as specified nad as directed by Engineer in Charge.
Supply and fix Heat shrink straight through joint LT 1100 volts grade 70-150 sqmm, 4 core, make-Raychem, Cat No-EPKJ0137 or equivelent of M-Seal/MS Seal/3M Complete all as specified nad as directed by Engineer in Charge.
Supply and fix Heat shrink straight through joint LT 1100 volts grade 185-300 sqmm, 4 core, make-Raychem, Cat No-EPKJ0144 or equivelent of M-Seal/MS Seal/3M Complete all as specified nad as directed by Engineer in Charge.
S&F surface mounting time switches, daily dial, , incl dismentling taking down unsv one, Make- Legrand, Model-Maxi-rex-4QT-6499 15 or equivelent model of ABB/Schneider/Merlin Gerin Complete all as specified nad as directed by Engineer in Charge.
S&F 3 pole power contactor, 415Volts, 40 amps, , incl dismentling taking down unsv one, Make-L&T, Type-ML-3, Cat No-SS90721 or equivelent model of ABB/Schneider Complete all as specified nad as directed by Engineer in Charge.
Supply and fix GI tubing light grade 40mm bore,on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection Complete all as specified nad as directed by Engineer in Charge.
Supply only GI tubing light grade 50mm bore on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection, ISI marked, for cable protection Complete all as specified nad as directed by Engineer in Charge.
Supply only GI tubing light grade 80mm bore,on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection ISI marked, for cable protection Complete all as specified nad as directed by Engineer in Charge.
Supplying and fixing 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 2.5 sqmm and overall PVC sheathed in service connections including 4mm suspension GI wire from OH conductor to building incl dismentling taking down unserviceable one all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 4 sqmm and overall PVC sheathed in service connections including 4mm suspension GI wire from OH conductor to building incl dismentling taking down unserviceable one all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 6 sqmm and overall PVC sheathed in service connections including 4mm suspension GI wire from OH conductor to building incl dismentling taking down unserviceable one all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 10 sqmm and overall PVC sheathed in service connections including 4mm suspension GI wire from OH conductor to building incl dismentling taking down unserviceable one all as specified and directed.
Supply & fixing 4mm dia Hot Dipped Galvanized Chain Link Fencing with Zinc Coating, including line wires, any type of standards, rails, straining bolts, etc. including provission of binding wire incl dismentling taking down unserviceable one (2.8 Kg per sqm with 2"x2" mess of 3 mm wire)
M&L for mild steel work of angle fixed independently for fencing post and others confirming to Gde Fe 410-A incl cutting to dead end length where required, notching, drilling, fitting and welding or connecting with bolts and nuts incl dismentling taking down unsv one complete all as specified and directed.
M&L for TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends or as in horizontal bar for fixing in fencing and binding with and including mild steel wire (anealed) not less than 0.9mm dia or securingwith clips complete for support of chain link fencing incl dismentling taking down unsv one all as specified and directed.
Supply and fix jumper connections of length up to 1.50 mtr with existing size and guage of ACSR, binding with existing conductors for LT OH lines complete as directed by the Engr-In-Charge.
M & L for Danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 1100 volts, 25 x 20 cm size
S & F street light pole box (SMC) type suitable for fixing LT pole size 30cmx25 cmx15cm with side hinged door and locking arrangment and suitable for terminal single phase including MCB 6-10A SP, and fixing in position with nut, bolt clamp incl dismentling old street pole box all as specified and directed.
M & L for street light bracket, made out of 40 mm dia GI pipe, (medium grade) 1.5 metre long bend to shape as required with nut bolt and clamp and fixing in position incl dismentling taking down unsv complete all as specified and directed.
Supply & fix of LED 45W street light, aesthetically designed roadway luminiare with excellent thermal management, pressure die-cast aluminium alloy for housing (heat sink) with epoxy powder coated with high efficiency long life LED chip inbuilt with electronic driver with APFC and including taking down old street light fitting with bracket of any type and from any position Make Crompton Cat part No LSTP-45-CDL or equivalent , HPL, Philips, Bajaj
Supply & fix of LED 60W street light, aesthetically designed roadway luminiare with excellent thermal management, pressure die-cast aluminium alloy for housing (heat sink) with epoxy powder coated with high efficiency long life LED chip inbuilt with electronic driver with APFC and including taking down old street light fitting with bracket of any type and from any position Make Crompton Cat part No LSTP-60-CDL-M or equivalent , HPL, Philips, Bajaj
Repair to any type of LT panel with cutting necessary worn out portion of MS sheet, angle iron and providing MS sheet of 2mm, MS angle iron of existing size and hinges to broken door etc fixed with electric arc welding, providing external locking arrangement after taking proper elctric shutdown. (Note: Material such as MS sheet, angle iron, hinges measured separately as supply only here-in-after)
Repair to any type of LT feeder pillar with cutting necessary worn out portion of MS sheet, angle iron and providing MS sheet of 2mm, MS angle iron of existing size and hinges to broken door etc fixed with electric arc welding, providing external locking arrangement and painting with one coat of red oxide to effected area complete afterafter taking proper elctric shutdown. (Note: Material such as MS sheet, angle iron, hinges measured separately as supply only here-in-after)
Supply only MS angle iron Fe 410-W (grade E-250 quality- A) of any size/MS sheet of any thickness /MS hinges (With ref to item No- 20) all as directed.
Painting both side of Iron angle fencing including iron gate after removing rust, loose paint, dirt ,scum or foreign matter and using two coats of same colour synthetic paint all as specified and directed.
Supply and fixing MCCB, 4 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 320 amps, incl dismentling taking down unsv one, Make- Legrand Cat Part No 4200 97 or equivelent model of Schneider/ABB/Merlin Gerin.
Supply and fixing MCCB, 4 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 200 amps incl dismentling taking down unsv one, Make- Legrand 4220 01 to 02 or equivelent model of Schneider/ABB/Merlin Gerin.
Supply and fixing MCCB, 4 pole,36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 160amps, incl dismentling taking down unsv one, Make- Legrand cat Part No 4202 38 or equivelent model of Schneider/ABB/Merlin Gerin.
Supply and fixing MCCB, 3 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 320 amps, incl dismentling taking down unsv one, Make- Legrand Cat Part No 4200 97 or equivelent model of Schneider/ABB/Merlin Gerin.
Supply and fixing MCCB, 3 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 200 amps, incl dismentling taking down unsv one, Make- Legrand Cat Part No 4200 86 or equivelent model of Schneider/ABB/Merlin Gerin.
Supply and fixing MCCB, 3 pole,36KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 160 amps, incl dismentling taking down unsv one, Make- Legrand Cat Part No 4200 87or equivelent model of Schneider/ABB/Merlin Gerin.
Supply and fixing MCCB, 3 pole,16KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 125 amps, incl dismentling taking down unsv one, Make- Legrand Cat Part No 4200 87or equivelent model of Schneider/ABB/Merlin Gerin.
Supply and fixing MCCB, 3 pole,16KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 40amps, incl dismentling taking down unsv one, Make- Legrand Cat Part No 4200 87or equivelent model of Schneider/ABB/Merlin Gerin.
Supply & Fix LED driver of 15/18/25/30 watt suitabe for 15/18/25/30 watt LED security light Make crompton, Bajaj, Philips, Surya or equivalent
Supply & Fix LED driver of 45/60 watt suitabe for 45/60 watt LED security light Make crompton, Bajaj, Philips, Surya or equivalent
Supply & Fix surge protector suitabe for 45 to 60 watt LED security light Make crompton Cat No SRPS-5K-440 Bajaj, Philips,surya or equivalent
Labour for disconnecting LT cable of any size from structure/pole/transformer for finding fault , M&L for defect rectification LT cable laid in trenches or any location by liacting fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 12 hours after notification, failing to which Rs500/- per day complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quioted rate all as specified and directed by Engr-in-charge. joint kit will be measured seperately in appropriate item in this schedule
Labour for disconnecting LT cable of any size from structure/pole/transformer for finding fault , M&L for defect rectification LT cable laid in trenches or any location by liacting fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 12 hours after notification, failing to which Rs500/- per day complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quioted rate all as specified and directed by Engr-in-charge. joint kit will be measured seperately in appropriate item in this schedule
Taking down defective HP SV/HP MV/MH/LED street light fittings any type,any capacity from 7.5 to 9 met height poles and bringing down to ground,carry out necessary repair work including replacement of defective spares required, testing on ground and refixing in its original position to the entire satisfaction of Engr-In-Charge.Note : I ) spares required for the repairs will be measured and paid seperately under relevant items of this schedule. II ) small items such as clamps,nut,bolts and washers are inclusive of quoted rates.
Supply and fix repair ballast-70 watts suitable for HPsv lamps.Make: Bajaj/Crompton/HPL/Philips.
Supply and fix repair ballast-150 watts suitable for HPsv lamps .Make: Bajaj/Crompton/HPL/Philips.
Supply and fix repair ballast-250 watts suitable for HPsv lamps .Make: Bajaj/Crompton/HPL/Philips.
Supply of Porcellin Holder screw type suitable for HP sv lamp 70 watts .Make: Bajaj/Crompton/HPL/Philips.
Supply of Porcellin Holder screw type suitable for HP sv lamp 150 watts .Make: Bajaj/Crompton/HPL/Philips.
Supply of Porcellin Holder screw type suitable for HP sv lamp 250 watts .Make: Bajaj/Crompton/HPL/Philips.
Supply of Ignitor suitable for HPDSV lamp 70 watts .Make: Bajaj/Crompton/HPL/Philips.
Supply of Ignitor suitable for HPSV lamp 150 watts..Make: Bajaj/Crompton/HPL/Philips
Supply of Ignitor suitable for HPSV lamp 250 watts..Make: Bajaj/Crompton/HPL/Philips.
Supply and replacement of PVC flexible cable 1.5 sqmm stranded copper conductor
Supply and fix Glow Sign board size 12'3" x 3'2" x 1'.1" at various sub stn holding on 3.5 mtr height MS pipe 32 mm, height 3 mtr, painting with one coat red oxide primer and 2 coat synthethic enamel paint, providing lighting /Illumination with two tuble light set
M&L for cleaning of MES Electric supply installations / campus by surface dressing or trimming of natural ground to remove small unequalities n.exc 15 cm deep ( including removing vegetation / shrubs / brush wood / under-growth ) & carrying away the rubbish to a distance of n.exc 50 mtr away complete at an interval of every 30 days for the following installations: -
All items as 104 but HT Main receiving sub station at TB-I approx area 900 sqm
All items as 104 but Substation 108 butAPS & Family accn approx area 600 sqm
All items as 104 but Substation at MAP Accn Depot Bn approx area 200 sqm
All items as 104 but Substation at Pioneer circle approx area 120 sqm
All items as 104 but Substation at Swimming Pool approx area 120 sqm
All items as 104 but Substation at Offrs Mess approx area 120 sqm
All items as 104 but Substation at TB-1 MAP Accn approx area 200 sqm
All items as 104 but Substation at Depot Bn Line Bazar gate approx area 120 sqm
All items as 104 but Sub station at TB-I near out door VCB approx area 120 sqm
All items as 104 but HT Main receiving sub station and back side structure120 sqm
Supply and fix PVC line seperator suitable for 4 conductors OH Line 1100 volts grade.
Supply and fix PVC line seperator suitable for 2 conductors OH Line 1100 volts grade.
Adinath Technical Services
ASHWAMEDH ENGINEERS
SOURABH ENGINEERS
Mahindra Electric Stores
metro electrical services
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .