Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.6 L+₹66,356.50 (1.41%)Rejected-Finance FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | L2 | Rejected-Finance Since Not Being Lowest | |
| 3 | L3₹47.8 L+₹86,631 (1.85%)Rejected-Finance H NO 767 NEAR OLD POST OFFICE NEW VADDEM VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L3 | Rejected-Finance Since Not Being Lowest | |
| 4 | L4₹49.9 L+₹3.0 L (6.47%)Rejected-Finance | L4 | Rejected-Finance Since Not Being Lowest | |
| 5 | L5₹50.2 L+₹3.3 L (7.11%)Rejected-Finance C2 PAIXOMONTIRO APTS BEHIND NSD ALTO DABOLIM VASCO DA GAMA GOA 403 801 | SOUTH GOA | GOA | 403801 | L5 | Rejected-Finance Since Not Being Lowest |
Tender Value
₹47.8 L
EMD Value
₹95,600
Closing Date
8 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI JITENDRA KUMAR MEENA IDSE EE
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802
8594/E8
2024_MES_651309_3
8594/E8
Open Tender
Civil Works
Item Rate
180 days
VASCO
Class D Category a i b i
7 documents required · 7 mandatory
₹500
GE (NW) VASCO
₹95,600
Yes
2 Dec 2024
26 Oct 2024
11 Nov 2024
26 Oct 2024
8 Nov 2024
2 Nov 2024
26 Oct 2024 - 1 Nov 2024
Amount
ADDN/ALTN TO FIRST FLOOR OF AIRCATS BUILDING NO P-672 AT INS HANSA. (B/R PORTION)
S&F Pre- painted 3mm thick UPVC 3 Layer Roofing Sheets of any colour as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam, tee, angle, channel or flat sections) confirming to Fe 410-W including cleats, distance pieces etc complete all as specified and as directed.
S&F for Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet including of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and as directed.
S&F for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.
S & F of Hangers made of 6 mm dia GI wire (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and as directed.
S & F of GI frame work for seamless ceiling grid of size 605 X 605 mm comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre, intermediate channel 0.90 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc. 1.20 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed.
S &F 10mm thick PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/ GI/ MS as per specification and drawing complete all as specified and as directed.
S & F Door Shutter of 12mm thick toughened glass with etching, steel handle, 2 Nos floor door springs, locking arrangement and fixing arrangement of each door shutter, silicon filling as required, All door fittings of Dorma Co. or equivalent make complete all as specified and as directed. Note :- All door fittings required for door are included in the rate of above items.
Taking down chowkat or frames exc 1.5 sqm but n. exc 4 sqm each (w/o taking off shutters from the frame) complete all as specified and as directed.
Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) Area not exceeding 2.00 sqm each complete all as specified and as directed.
S&F 4mm thick sheet glass ordinary quality exceeding 0.5 sqm each pane complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L Vitrified Ceramic tiles light / dark shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors laid over and including 20 mm thick screed in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of floor complete all as specified and as directed.
All as per item No. 16 here in before as in skirting/dado but in 10 mm thick rendering in CM 1:4 complete all as specified and as directed.
M&L for coloured Glazed ceramic tiles in vertical surfaces 350 x 250 x 7mm / 450 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including 10 mm thick screed bed in CM 1:4 complete all as specified and as directed.
M&L for preparation of steel surface and applying and two coats of Epoxy anticorrosive paint over 10 cm width or girth over a coat of red oxide zinc chrome primer
M & L for Pre - cast cement concrete block masonry type C1 1:3:6 (20mm graded stone aggregate) solid blocks, exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on concrete solid block wall external surface finished even and smooth without using extra cement complete all as specified and as directed. Note :- Water proofing compound measured and paid separately.
M & L for preparation of new surfaces walls and applying two coat of acrylic anti-fungal weather proof exterior grade paint of first quality over a coat of primer incl sealing the cracks all as specified in manufacturers instruction Make STP Ltd (Shallcry - 215)/ Asian Paint (Ultima stretch)/ Berger Paint (Weather coat long) all as specified and as directed.
M& L for rendering 15 mm thick in CM 1:6 on concrete solid block wall internal surface finished even and smooth complete all as specified and as directed.
M & L for preparing new surfaces of walls and applying two coats of oil bound distemper over alkali resistant primer over 1-2mm thick wall care putty in two coats (smooth bodied opaque finish surface) on walls complete all as specified and as directed.
Granite (of any type) work 20mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and laid over screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Supply only liquid water proofing compound
M & L for cement concrete type B1 1:2:4 (20mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
INTERNAL ELECTRIFICATION SERVICES
M & L Point wiring with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multistranded copper conductor cable in and including PVC concealed conduit 20 mm dia medium grade ISI marked including fittings and accessories with continues PVC insulated copper cable with copper conductor of same size as in phase / neutral / earth cable connecting to common earth dolly including metal flush box and white cover plate with frame complete.
Light, fan point controlled by one way switch
5 Amp Socket point on same board
5 Amp Socket point on independent board
S&F ceiling rose 3 terminal 230 volts, PVC polycarbonate, isolated body complete all as specified and as directed.
S & F in repairs Modular switch 1 way 6A, 1 module complete all as specified and as directed.
S & F in repairs Modular switch 1 way 16A, 1 module complete all as specified and as directed.
S & F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed.
S & F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
M&L for point wiring with FRLS cable size 2.5 Sq mm nominal area PVC insulated and unsheathed cable single core multistranded, copper conductor in PVC concealed conduit for one 3 pin, 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm complete all as specified and as directed.
M&L for Point wiring with FRLS cable size 4 Sqmm (nominal area) PVC insulated unsheathed multistranded copper conductor cable in and including PVC concealed conduit medium grade ISI marked including fittings and accessories with continues PVC insulated copper cable with copper conductor of same size as in phase / neutral / earth cable connecting to common earth dolly for geyser/Ac point complete all as specified and as directed.
S & F MCB TPN 63 Amps 415 volts complete all as specified and as directed.
S & F MCB TP 63 Amps 415 volts complete all as specified and as directed.
S & F MCB SP 6 to 32 Amps 240 Volts complete all as specified and as directed.
S & F MCB SPN 6 to 32 Amps 240 Volts complete all as specified and as directed.
S & F MCB SPN 6 to 32 Amps 240 Volts complete all as specified and as directed.
S & F MCCB 4 Pole 125 Amps 415 Volts 18 KA complete all as specified and as directed.
S&F MCCB Vertical TPN DB Galvanised door IP 43, 4 way 415 volts with provision of 4 pole MCCB Incomer and MCB SP/TP as outgoing complete with Provided insulated vertical phase bus-bars complete all as specified and as directed.
S&F MCB DB TPN double door 4 way 415 volts complete all as specified and as directed.
S&F RCCB 4P 63 Amp, sensitivities for a veriety of applications 300 mA complete all as specified and as directed.
M & L for sub main wiring in replacement with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10sqmm alongwith one run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through PVC conduit as reqds size confirming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area.
S & F in repairs LED panel 2' x 2' recess mounting luminaire suitable for armstrong/ grid / Pop ceiling complete with separate electronic driver & high brighteness SMD Leds complete all as specified and as directed.
S & F LED down light with round shaped low depth & larger dia, powder coated white finish with drop down PC diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver suitable for office & retail spaces of capacity 12 W 230 V .
S & F 20/25 Amps motor starter switch with overload protection, ideal & safe for air conditioners cooler, water pumps, refrigerators Mixer and all type of appliances complete all as specified and as directed.
S & F 20/25 Amps Power unit combo MCB protected socket with top, ideal & safe for air conditioners cooler, water pumps, refrigerators Mixer and all type of appliances complete all as specified and as directed.
S & F LED MS batten with decorative end cap complete with retrofit T8 glass tube light 20 W 230 V .
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
Supply and fix rigid non-metallic PVC conduit of 20 mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
Supply and fix non metallic rigid PVC junction boxes 1 to 4 way 32 mm dia, concealed in wall/ceiling for TV/ Telephone cable all as specified and directed
Supply and fix Telephone socket with PVC box complete all as specified and as directed.
M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/ bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR Part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil mixed with peddy field earth including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
AIR CONDITIONING
Supply and install hi wall split AC units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of 1.5 Ton capacity complete all as specified and as directed.
M & L for FRLS sub main wiring with two runs of single core PVC insulated unsheathed 1100V grade multistranded copper conductor cable 4 Sqmm size incl suitable size PVC casing caping double deck type with accessories fixed in wall incl one run 2.5 Sqmm PVC insulated unsheathed copper conductor cable as earth wire complete all as specified.
S&F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified and as directed.
Supply and install voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and as directed.
EXTERNAL ELECTRIFICATION
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm x 3.5 core complete all as specified.
Supplying & Fixing GI pipe light grade ISI marked including all fittings on wall or laid on floor as required position of size 80 mm bore all as directed.
Excavation in trenches by cutting of road/concrete/bituminous/PCC hard standing getting out and levelling of bottom surface to required level for laying of UG cable/pipe all as directed.
Material and labour for PCC 1:3:6 type C1 using (20 mm graded stone aggregate) for making good disturbed road surfaces including necessary use and waste of form work complete all as specified and as directed.
S & F MCCB 4 Pole 125 Amps 415 Volts 18 KA complete all as specified and as directed.
LIGHTENING PROTECTION
Supply and fix single point air termination alluminium rod, 12mm dia, 300mm long including provision of mounting on upto 1 mtr length GI pipe, nuts bolts, washers, rigid fixed on top roof height and insulated from base complete all as specified and as directed.
Supply and fix aluminium strip 25mm x 3 mm complete with saddles and fixing screws for fitting the strip complete all as specified and as directed.
M & L for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil with peddy field earth etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed by Engr-in-charge including demolish existing earth pit taking out old materials.
M & L for test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled and scrwed including 3 Nos. 8 mm dia 25 mm long hex. Head screw complete all as specified and as directed.
S & F Galvanised iron strip 25 x 4 mm with saddles and fixing screws etc. for ring conductor under the ground complete all as specified and as directed.
Supply and fix GI tubes light grade with all fittings 40 mm dia fixed on the roof for Air termination
M&l for PCC 1:3:6 Type C-I using 20 mm graded aggregate for PCC of size 0.15m x 0.15m x 0.15m cube with MS ferule for mounting GI pipe 40 mm Dia complete all as specified and as directed.
CONSTRUCTION OF RADSIM ROOM ADJOINING AIRCATS BUILDING (P-672) (B/R PORTION)
Excavation in trenches not exc. 1.5 m in depth and not exc 1.5 m wide in soft disintegrated rock for foundation and getting out complete all as specified and as directed.
Returning, filling in with soft/ disintegrated rocks, including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and as directed.
Removing excavated material n.exc. 50 m and depositing/spreeding where directed at a level n.exc. 1.5 m above the starting point complete all as specified and as directed.
PCC type D2 1:4:8 (40mm aggregate) in foundations filling and mass concrete complete all as specified and as directed.
M&L for RCC Type B1 1:2:4, 20mm graded aggregate as in foundation, Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for Mild steel bars 10 mm dia and over, cut to length, bent to shape required including crancking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to TMT Bars complete all as specified and as directed.
M&L for Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including crancking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to TMT Bars complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and as directed.
M&L Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with 3% integral water proofing compound finished to even & smooth w/o using extra cement complete all as specified and as directed. Note :- Integral water proofing liquid will be measured and paid separately
M & L for preparation of surfaces by complete removal of existing treatment of painted walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm complete all as specified and as directed.
M & L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing / pavings / plinth protections, etc.
M&L for rendering 10mm thick in cement plaster 1:6 on stone / block masonry surfaces or surfaces other than fair face of brick work to receive glazed tiles complete all as specified and as directed.
S&F UPVC sound proof casement door (IDEAL 2000) of dimension 1.20 m x 2.10 m fitted with laminated toughened glass of thickness 14.76 mm, ESPAG handle type and necessary foam sealent with complete testing for 60 DbA ambient room noise complete all as specified and as directed.
S&F UPVC sound proof Fixed window (IDEAL 2000) of dimension 2.38 m x 1.17 m fitted with laminated toughened glass of thickness 14.76 mm and necessary foam sealent with complete testing for 60 DbA ambient room noise complete all as specified and as directed.
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with ANF (Board) edge tiles with Armstrong 24mm exposed grid. The tiles should have Humidity Resistance (RH) of 90%, NRC 0.5, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 34%.The tile shall be laid on Armstrong Prelude38 with 24 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15.34Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. The Tile & Grid system used together should carry a 10 year warranty all as directed.
S & F in curtain rods along with designer holders at both sides of mild steel, chromium plated with fixing brackets, stops, rollers etc.
S&F MCB DB SPN double door 8 way 415 volts all as specified and as directed.
M/S jvsr constructions (BID ID -3159940)
M/S DUBAL CONSTRUCTION (BID ID -3159971)
M/S Kartik Enterprises (BID ID -3160388)
M/S P S BABU (BID ID -3159541)
Super Construction (BID ID -3160721)
STAR FABRICATION (BID ID -3159821)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .