Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.6 L+₹61,423 (4.74%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹23.0 L+₹10.1 L (77.6%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹24.4 L+₹11.5 L (88.6%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹24.8 L+₹11.8 L (91.3%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L5 | Rejected-Finance Not lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
11 Mar 2020, 6:00 pmClosed
GE South Pathankot
GE South Pathankot
Repair/Maint of water supply pipe lines, tubewell pump sets, fire fighting pump sets, starter panels, dozing pumps and allied works at 18 FAD Unchibassi under GE (South) Pathankot.
2020_MES_316224_2
GEs/PKT/T-54/2019-20
Open Tender
Civil Works
Item Rate
180 days
Unchibassi
Refer tender documents and NIT
9 documents required · 9 mandatory
₹500
GE South Pathankot
₹50,000
Yes
9 May 2020
2 Mar 2020
12 Mar 2020
2 Mar 2020
11 Mar 2020
4 Mar 2020
2 Mar 2020 - 3 Mar 2020
Amount
Excavation in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide in any type of soil for laying and taking out of GI/CI pipes all as specified and directed by Engr-in-Charge
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as directed.
Removing excavated soils to a distance not exceeding 50 m and depositing where directed by Engr-in-charge.
Taking down cast iron pipe line of size 150 mm bore, including all fittings with spigot and socket/ flanged end or any type, lead joint including removing to store complete all as specified and directed.
Taking down/Cutting MS pipe line of size 150 mm bore, including all fittings of any type complete all as specified and directed.
M&L in replacement of cast iron 150 mm bore pipe with flanged ends,centrifugally cast class 'B' in any length laid in trenches as taken down under Srl item 4 here-in-before complete all as specified and directed.
M&L in replacement of cast iron 150 mm bore pipe with spigot and socket ends,centrifugally cast class 'LA' in any length laid in trenches as taken down under Srl item 4 here-in-before complete all as specified and directed.
All asper item No 5 above but MS pipe line of size 150 mm bore with plain ends ERW (Heavy grade as per latest IS) in any length laid in trenches by means of welding (For firefighting installation) complete all as specified and dorected.
Relaying the CI/MS pipe line of size 150 mm bore after cleaning as taken down under Srl item No 4 and 5 here-in-before including all fittings with spigot and socket end/flanged complete all as specified and directed.
Taking up and down old/unserviceable CI/MS tubing with fittings of size 100 mm bore (earth work will be measured and paid separately).
All as per Srl No 10 above here-in- before but of size 80 mm -do-
All as per Srl No 10 above but GI pipe here-in- before but of size 50mm -do-
All as per Srl No 10 above but GI pipe here-in- before but of size 40mm -do-
All as per Srl No 10 above but GI pipe here-in- before but of size 25mm -do-
All as per Srl No 10 above but GI pipe here-in- before but of size 20mm -do-
All as per Srl No 10 above but GI pipe here-in- before but of size 15mm -do-
Laying and re-fixing only old but serviceable CI/MS tubing 100 mm obtained from Ser item no. 10 after cleaning and laying in exiting trenches with required fittings all as directed by Engineer in Charge.
All as per Srl No 17 but obtain from Srl Item No. 11 above here-in- before but of size 80 mm
All as per Srl No 17 but GI pipe obtain from Srl Item No. 12 above here-in- before but of size 50mm
All as per Srl No 17 but obtain from Srl Item No. 13 above here-in- before but of size 40mm
All as per Srl No 17 but obtain from Srl Item No. 14 above here-in- before but of size 25mm
All as per Srl No 17 but obtain from Srl Item No. 15 above here-in- before but of size 20mm
All as per Srl No 17 but obtain from Srl Item No. 16 above here-in- before but of size 15mm
M&L for supply, fixing and laying cast iron pipe with spigot & socketed ends centrifugally cast class LA 100 mm bore ISI marked suitable for lead joint in any length laid in trenches complete all as specified and directed by Engr-in-Charge. (Excavation shall be measured and paid separately)
All as per Srl No 24 above here-in-before but class LA of size 80 mm
All as per Srl No 24 above here-in-before but MS pipe line of size 100 mm bore with plain ends (Heavy grade as per latest IS) in any length laid in trenches by means of welding (For firefighting installation) complete all as specified and directed.
M & L for supply,fixing & laying in exiting trenches GI water tubing 50 mm bore medium grade ISI marked with all required fittings such as bends elbows, tees short pieces, connector check nuts & threading complete all required at work site.(Excavation shall be measured and paid separately)
All as per Srl No 27 above here-in- before but of size 40 mm
All as per Srl No 27 above here-in- before but of size 25 mm
All as per Srl No 27 above here-in- before but of size 20 mm
All as per Srl No 27 above here-in- before but of size 15 mm
M&L for Run lead joints complete with spun yarn of size 150 mm dia all as directed by Engr-in-Charge
M&L for Run lead joints complete with spun yarn of size 100 mm dia all as directed by Engr-in-Charge
M&L for Run lead joints complete with spun yarn of size 80 mm dia all as directed by Engr-in-Charge
Supply & fixing CI fittings up to 150 mm bore such as ( any type, bend/color/reducer and angle) tapers any type (straight, bends increasing,decreasing or double socket etc) tail pieces single branch Y junction,double branch cross (all sockets or socket ends spigot). All as required at work site and as directed.
M & L for S&F of CI sluice valve flanged of size 150 mm bore class PN-1.0 ISI marked with stainless steel spindle and iron wheel head complete with rubber gaskets, nuts, bolts washers and packing materials etc all as directed and as per site requirement.
All as per Srl No 36 above here-in- before but of size 100 MM -do-
All as per Srl No 36 above here-in- before but of size 80 MM -do-
Supply and fixing of CI non return valve of size 150 mm bore flanged ISI marked including bolts, nuts, washers and rubber gasket etc complete all as directed.
Supply and fix Cast Iron Foot valve including necessary fittings conforming to ISI mark conformed of size 100 mm bore all as specified and directed by Engineer-in-Charge.
All as per Srl No 40 above here-in- before but of size 150 MM -do-
M & L for supply and fixing Gun metal gate valve ISI marked with iron wheel head screwed both ends for pipe of size 50mm .
All as per Srl No 42 above here-in- before but of size 40 MM -do-
All as per Srl No 42 above here-in- before but of size 25 MM -do-
All as per Srl No 42 above here-in- before but of size 20 MM -do-
All as per Srl No 42 above here-in- before but of size 15 MM -do-
Cutting existing CI/MS water main 150 mm bore pipe in position for making branch connection and CI pipeline (Insertion of CI tees bends of different size on connection pieces or for insertion of sluice valve) including excavation & earth work. Note : Cast iron fittings such as tees, bends, collars reducers etc) joints and jointing material for fixing cast iron fittings, sluice valve shall be measured and paid separately.
All as per Srl No 47 above here-in- before but of size 100 mm
All as per Srl No 47 above here-in- before but of size 80 mm
Repair to GI pipe lines of size 15mm to 50 mm bore dia and repair to leaked joints of pipe line complete including replacement of GI fitting i.e union,nipple & sockets if required including excvation and taking up & down required cutting & threading refixing in position in trenches & all as directed.
Dismantling of old U/S valve pit of size 120x120x90 Cm (internal dimensions of the chamber) including and removing the unserviceable material at a distance not exceeding 50 Mtr including brick massonary with cement mortar with 1: 6 , 23 cm and flush pointing externaly work proceeds in the same mortar complete ( using 30% old bricks & 70% New bricks) complete with the following specification and as directed by Engr-in-Charge.
(i) 10mm thick plaster internally in CM 1:6
(ii) Flooring 40mm thick in PCC 1:2:4 type B-1 over 75mm thick hard core of guage not exc 63mm thick.
(iii) Angle iron frame 40X40X6mm thick for cover and mild steel 3mm thick cover with locking arrangement,handle and necessary hinges etc, .
(iv) PCC 1:3:6 type C-2 100mm thick in foundation
(v) Two coat of synthetic enamelled paint to cover internally and externally over a paint of Red Oxide primer.
All as per Srl No 51 to 56 above here-in- before but of size 100x100x105 cm
M&L joints with rubber gaskets for CI flanged pipe including necessary nut bolts and washers etc for pipe 80 mm bore all as specified.
All as per description of srl item 58 here-in-before but of size 100mm bore.
All as per description of srl item 58 here-in-before but of size 150mm bore.
S&F replacement brass spindle with checknut suitable for sluice valve of size 80 mm bore including replacment of gland packing all as directed make : BIR/VENUS/MINAR
All as per description of srl item 61 here-in-before but of size 100mm bore.
All as per description of srl item 61 here-in-before but of size 150 mm bore.
Taking out electric submersible/vertical turbine motor of capacity 20 to 30 Hp from the existing foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge including other allied items such as varnish tape, sleeve, greasing etc. of suitable size for following capacity of motor and refixing after testing and commisioning complete all as specified and directed
Removal of unwanted vegetation/bushes/small plants shrubs around the water supply installations/ inside the valve pit and surface excavation not esceeding 15 cm depth leveling the ground and removing the excavated material to a distance exceeding 50 M.
M&L for cleaning of RCC over head reservoir of 30,000, gallons capacity at 40/60 feet staging including removal of all deposited scales, dirt and settled sand particles from intake of circulating pipe, cleaning with brushing, sweeping and brooming of inner and outer wall of the tank and washing the complete with bleaching powder soluting and also re-writing date of cleaning and marking all as directed by Engr-in-Charge. Note : - Cleaning of all O/H tank will be carried out 2 times
M&L for cleaning of RCC over head reservoir of 25,000 gallons capacity at 40/60 feet staging including removal of all deposited scales, dirt and settled sand particles from intake of circulating pipe, cleaning with brushing, sweeping and brooming of inner and outer wall of the tank and washing the complete with bleaching powder soluting and also re-writing date of cleaning and marking all as directed by Engr-in-Charge.
M&L for cleaning of RCC over head reservoir 1,00,000 gallons capacity at 40/60 feet staging including removal of all deposited scales, dirt and settled sand particles from intake of circulating pipe, cleaning with brushing, sweeping and brooming of inner and outer wall of the tank and washing the complete with bleaching powder soluting and also re-writing date of cleaning and markingall as directed by Engr-in-Charge.
M & L for two coats of cement based paint of special colour as approved by Engr-in-charge for external surfaces of RCC over head tank reservior upto 40/50 feet staging and tank capacity 1 lakh gln to 25 thousand gln including painting to iron ladder from bottam to top of overhead tank with existing colour, ventilation hole will be covered with wiremesh and preparation of surface all as specied and directed by Engr-in-charge
Supply & fixing in repairs 4 pole MCCB, 250 Amp, breaking capacity 25 kA with adjustable Thermal & Magnetic setting fitted in panel with all connecting accessories complete all as specified and as directed.
Note : Excavation, Sluice valve, NRV, CI Fittings ,PCC work will be paid separately under Relevent items.
PCC (1:3:6) type C2 with 40 mm graded aggregate for grouting Anchoring, MS Band Strap and bolts, finished even and smooth complete all as specified and directed by Engr-in-charge.
S&F in repairs Change over switch, 200 Amps rating, four pole, AC, 415 V, on-load type complete all as specified and as directed.
Supply only water testing kit complete assembly
Taking out, cleaning and removal of dry and wet sand, grass inside the valvpits any sizes, cleaning of grass 1 mtr surrounding area of valvepits out side all as specefied and direced by Engr-in-Charge.
S&F fully automatic star-delta starter of capacity 40 HP, 30 - 50 Amp, in sheet metal enclouser, AC-3 phase, 415 Volts, 50 Hz, with-over load protector and electronic timer, including taking out old unserviceable one all as specified and as directed by the engr-in-charge.
Supply, Installation, commissioning and testing of Aviation obstruction LED light Double dome ,IP33 rating, Intennsity 32.5 CD. Insta Power red Painted housing, Red coloured Polycarbonate dome and accessories complete all as specified and directed by Engr in charge.
S/F pressure gauge 100 mm size,jelly filled, fixed in repair with suitable cock and raiser pipe with fitted on delivery side of pump set incl dismentling old one
S&F in replacement unserviceable fire hydrant valve brass 65mm dia ISI mark (One end flanged and drilled holes) fitted with packing materials nut, bolts with washers complete all as specified and directed
S&F rubber mat 1x 2 mtr 19 mm thick laid down in front of LT panel / bus bar complete ISI marked.
Supply and fixing battery heavy duty 12 volt 180 Ah heavy duty with battery leads. Make ; exide/Amaron/equvalent.
Supply only search light reachargeable heavy duty.
Supply and fixing pvc insulated copper conductor multistandardcable of size 25 sqmm single core.
Repair/Replacement of Centrifugal/Diesel pump set gland packing pump set to arrest lekage of water all as specified and directed by the Engr-in-charge
S&F in non percolated fire chief brand cotton synthetic fibre circular woven jacketed, ruberized fabric reinforced rubber lined (RRL) fire hose, delivery treated against rot with mystox, having 38 Kg/cm2 brust pressure, 22kg/cm2 proof pressure, 14kg/cm2 working pressure bearing IS 636-1988 type A mark & having TAC & MMD approval 63 mm inside dia in 15 mtr length with ISI marked male and female instantaneous coupling with copper binding complete all as specified and directed by Engr-in-charge
Painting fire hydrants hose boxes as per existing sizes complete including cleaning, scraping of old rusted surface paint inside and outside of panel surface with two coats of synthetic enamel paint and writing of SRL No as per existing size complete all as specifid and directed
S&F in replacement of broken glass of fire hydrant panel withnglass size 80cm x 14cm x 5 mm thick end covered type including rubber beading for finish of glass as per sample kept in the office of AGE E/M Unchibassi and directed by Engr-in-charge.
Taking out firefighting motor from the existing foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge including other allied items such as varnish tape, sleeve, greasing etc. of suitable size for following capacity of motor and refixing after testing and commisioning complete all as specified and directed :-
(a) 90 to 105 HP
(b) 20 to 30 HP
S&F hose box made out of 2 mm thick sheet size 100 cm x 45 cm x 60 cm with a provision two fix MS flanged pipe for hanging of hose pipe , MS line to accommodadate hose pipe ,with front double window size 27 cm x 90cm , with glasses size 80 x 14 cm each with rubber beading with locking arrangements, painted red colour and numbered with white paint and opening the valves should be outside and inside the box only hose pipe safety all as specified and directed by Engr-in-Charge. complete make : Newage / ISI marked. Note: Hose box should be fitted in PCC / Brick foundaction of 65cm x 50cm x 15 cm size.
S&F fully automatic star-delta starter in sheet metal enclouser, AC-3 phase, 415 Volts, 50 Hz, with-over load protector, single phase protection relay and electronic timer, including taking out old unserviceable one all as specified and as directed of the following capacity :-
M & L for removing existing Centrifugal pump set from base frame after disconnecting suction & delivery lines replacing bearings, repairing and grinding the shaft etc complete and reassembling and fixing back to original position and testing, commissioning etc complete all as directed for the following:- (Notes :- Any minor part up to Rs 2000 if required will be provided by contractor without any extra cost.)
(a) 105 HP Pump Set
(b) 25 HP Pump Set
M & L for removing existing Fan blade from pump set motor and replacing and reassembling and fixing back to original position and testing, commissioning etc all as directed complete for the following capacity :-
(a) 105 HP Pump Set
(b) 25 HP Pump Set
M&L in replacement of Pump shaft for 105 HP/75 KW capacity pumping set, including sleeves, machining, threading ,making key slot etc. complete all as directed.
M&L in replacement of coupling set with all accessories for Pump shaft of the following capacity pumping set ,including machining ,threading, making key slot etc.as directed.
(a) 105 HP/75 KW Pump Set
(b) 30 HP/18.5 KW Pump Set
M&L in replacement of CI impeller for 105 HP/75 KW capacity pumping set all as directed.
M&L in replacement of gland coupling brass bush for the following pumping set all as directed:-
(a) 105 HP/75 KW Pumpset
(b) 30 HP/18.5 KW Pumpset
M&L in replacement of gland cup including changing gland rope for the pumping set of capacity 105 HP/75 KW all as directed.
Servicing and maintaining pumping installation by tightening the gland of pump ,replacing rubber coupling ,bushes and clearing the leakage of sluice valves, NRV's, aircock, pressure guage by tightening gland etc. comprising 2 Nos pump sets of capacity 105 HP/75 KW 2 Nos complete all as specified and as directed.
Supply & fix in replacement of MCCB 4 Pole 415 Volts 3 phase 200 Amps 36 KA, thermal magnetic release S1 -01 No (incoming) with adjustable Thermal & Magnetic setting fitted in panel with all connecting accessories complete all as specified and as directed.
Supply & fix in replacement of MCCB 4 Pole 415 Volts 3 phase 630 Amps 50 KA, thermal magnetic release S1 -01 No (incoming) with adjustable Thermal & Magnetic setting fitted in panel with all connecting accessories complete all as specified and as directed.
Supply only (Calcium based granular disinfectant for water treatment, more stable than Chlorine Gas, and stronger than bleachingpowder, and sodium Hypochlorite) packing in 45 kg drum completed all as specified & directed by Engr-in-Charge.
Repair / replacement of chlorination injector motar as per existing motor specifications all as specified and directed by the Engr-in-charge.
Dismantling and opening the Chemical dosing pump from the existing position for servicing from authorised compeny and refixing the same in original position and testing and commissioning the pump all as directed and specified by Engr-in-charge.
M & L for Antisyphon valve suitable size for exisitng chemical dosing pump
M & L for Foot valve suitable size for exisitng chemical dosing pump
M & L for Tubing (LDPE) suitable size for exisitng chemical dosing pump with necessery fittings
S & F in repair chlorination dosing sysetm booster pump of capacity S/D size 1" x 1" ( (0.5 HP) 4 stage with suitable coupling all as directed.
S & F in repair chlorination dosing system motor 3 phase 400/440 volts 50 CS of 0.5 HP capacity all as directed.
S & F Flate 3 core 1100V grade PVC insulated and seathed 16 Sqmm nominal area strandard copper conductor water proof cable suitable for submersible pump motor including connection cable to strater.
Sch of Credit = 71720.00
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
M/s SODHI SALES CORPORATION
M/S SHRI RAM BUILDERS
M/S Vijay Punj Constructions
SATISH AND CO
Vijay Kumar Contractor and Engineers
commercial traders
INDERJIT SINGH
satpal and brothers
KEWAL SONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .