Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.6 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | 1 | Accepted-AOC BEING L1 | |
| 2 | 2₹27.8 L+₹2.9 L (11.7%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | 2 | Rejected-Finance Reject being not L1 | |
| 3 | 3₹30.4 L+₹5.5 L (22.2%)Rejected-Finance | 3 | Rejected-Finance Reject being not L1 | |
| 4 | 4₹31.6 L+₹6.7 L (27.1%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | 4 | Rejected-Finance Reject being not L1 | |
| 5 | 5₹34.1 L+₹9.2 L (37.2%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | 5 | Rejected-Finance Reject being not L1 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
6 Nov 2024, 6:00 pmClosed
GE UTILITY ELEC SUPPLY
GE UTILITY ELEC SUPPLY DELHI CANTT
REPAIR AND MAINT OF LT PANEL ACBs MCCBs EARTHING AND CONNECTED ITEMS AT MANEKSHAW MARG URBAN VILLAGE MALL ROAD POLO ROAD CHURCH ROAD TIGRIS ROAD CASSEL ROAD STATION ROAD MANDIR MARG MAUDE ROAD 4 NO P/F HARBAKSH STADIUM TUBARAK LINES 972 TPT COY PARAD
2024_MES_678766_1
GE ELEC/D-61/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELEC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELEC SUPPLY
₹99,000
Yes
28 Dec 2024
9 Oct 2024
7 Nov 2024
9 Oct 2024
6 Nov 2024
23 Oct 2024
Amount
Dismantling, taking down and removing the old existing un serviceable non-functional / broken hinges of any description and in any position of existing feeder pillar boxes/LT panel boards etc and supply and fixing new cold rolled medium weight mild steel hinges and door handels in position as per existing requirement with necessary spot welding, screwing etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed by the Engg-in-Charge.
Replacement of existing unserviceable/damaged part/portion of the existing feeder pillar box/ panel boards with supply and fixing new part or portion fabricated out of 2 mm thick MS sheet in position including making necessary adjustments and alignments to make the existing feeder pillar box/panel board body to required shape and size(s) complete all as specified and directed by the Engg-in-Charge. Note :- (a) The panel board repaired shall be made totally enclosed, weather proof for installing incoming/out going MCCB/switch fuses/ cable etc. complete all as directed. (b). The work is required to be executed in patch works and the rates quoted by the contractor are deemed to be with and including necessary cutting, welding, leveling, jointing and providing gasket for weather proof etc. as directed to match & accommodate with the existing feeder pillar box / panel board enclousers. (c).The replaced portion shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer with necessary filler coating.
Disconnecting and taking out old existing unserviceable Phase indication lamps and supply, fixing, connecting and, testing LED type Phase indication lamp with showing red, yellow and green colours of 22.5mm dia fixed to monitor on LT panel board suitable for 240 Volts AC supply and making connections with using suitable size copper cables wires and lugs complete all as specified and directed by the Engg-in-Charge. Make : L&T/AE/HPL or equivalent.
M&L for preparation of old steel surfaces of steel/LT panel boards/feeder pillar boxes of any description & any position including removing disintegrated/detoriating part of paint and applying filler coat to obtain smooth surfaces and applying a coat of synthetic enamel paint using spray machine to obtain smooth finish complete all as specified and directed by the Engg-in-Charge.
S&F in repair MCCB 415V AC, 4 pole should have reverse load and line termination, For 32-100 A:Should have breaking capacity of min.16 KA with thermal release adustable from 80 to 100% & fixed manetic release with Ics=100% Icu. For 100-160 A:Should have breaking capacity of min.25 KA with thermal release adustable from 80 to 100% & fixed manetic release with Ics=100% Icu.For 200-315 A:should have breaking capacity of min.25 KA with thermal release adustable from 80 to 100 % and magnetic release adustable from 5 to 10 In with Ics=100% Icu.For 400-630 A:should have breaking capacity of 36 KA and thermal release adjustable from 80 to 100% and magnetic releases adjustable from 5 to 10 In with Ics=100% Icu. with adjustable overload and adjustable short circuit protection in existing LT panel/provn of fixing arrangements by cutting and drilling busbar to exact size/provision of copper leads of suitable size at site to fix MCCB in existing panel including provision of thimbles and nut bolts of proper size and having following cap:-
MCCB 630 Amp 4 pole.
MCCB 400 Amp 4 pole.
MCCB 250 Amp 4 pole.
MCCB 200 Amp 4 pole.
MCCB 160 Amp 4 pole.
MCCB 100 Amp 4 pole.
Cleaning of substations, removing of stones, mud, or any other type of material from the sub station including removing of bushes and throwing them out from cantt area complete all as specified and directed by the Engg-in-Charge.
M&L for PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate in wall or retaining walls, any thickness, size or shape including plaster, buttresses columns, pillars and posts including caps and bases complete all as specified and directed by the Engg-in-Charge.
S&F in repair ACB, fixed type, shall confirm to IEC 60947 /IS 13947 (Part 1 & 2). The minimum breaking capacity should be 50KA. The service short circuit breaking capacity (Ics) should be equal to ultimate breaking capacity (Icu) and short time with stand capacity (Icw) with ICS =Icu=Icw. The Icw value is for 1sec. The ACB shall have microprocessor based protection units with flexible and adjustable current - time protection settings for overload, short circuit, instantaneous short circuit and Earth Fault Protections. ACB should be suitable for a 3 phase service voltage, up to 690V for 50/60 Hz AC supply and shall have an insulation voltage of 1000V. All the protection units should have built in Dedicated inbuilt LEDs for fault indication for overload, short circuit and Earth Fault complete all as specified and directed by the Engg-in-Charge. Makes : Legrand/schneider/Siemens .
ACB 800 Amp 4 pole.
ACB 1000 Amp 4 pole.
S&F in repair Junction box thermoplastics polystyrene/polycarbonate enclosure, shock proof, IP65( weather proof), rust proof, dust proof, water proof, internally embedded gasket with provision for all side cable entry through glands(IP-65) and/or grommets(IP-55). Size of enclosure: (205x255 x112) mm With suitable connecters for 2Ph/1Ph loop in loop out and branch out vibration proof connections complete all as specified and directed by the Engg-in-Charge.
S&F in repair aluminium lugs of size 800 Sqmm complete all as specified and directed by the Engg-in-Charge.
S&F in repair aluminium lugs of size 630 Sqmm complete all as specified and directed by the Engg-in-Charge.
S&F in repair aluminium lugs of size 400 Sqmm complete all as specified and directed by the Engg-in-Charge.
S&F in repair aluminium lugs of size 300 Sqmm complete all as specified and directed by the Engg-in-Charge.
S&F in repair aluminium lugs of size 185 Sqmm complete all as specified and directed by the Engg-in-Charge.
S&F in repair aluminium lugs of size 120 Sqmm complete all as specified and directed by the Engg-in-Charge.
S&F in repair aluminium lugs of size 95 Sqmm complete all as specified and directed by the Engg-in-Charge.
S&F in repair aluminium lugs of size 70 Sqmm complete all as specified and directed by the Engg-in-Charge.
S&F in repair aluminium lugs of size 50 Sqmm complete all as specified and directed by the Engg-in-Charge.
S&F in repair aluminium lugs of size 35 Sqmm complete all as specified and directed by the Engg-in-Charge.
S&F Danger notice plate of 1.6mm thick MS sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal Red colour and inclusive fixed with MS flat clamps 25x3mm 2 Nos, nuts, bolts for LT 440 volt of size 20x15cm incl dismantling of existing worn out notice plate complete all as specified and directed by the Engg-in-Charge.
S&F Iin repair multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 06 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by the Engg-in-Charge.
S&F in repair multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 10 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by the Engg-in-Charge.
M&L for painting to transformer guard (XPM), fencing channels mounted on plinth to all steel parts with silver aluminium paint one coat complete all as specified and directed by the Engg-in-Charge. (approx 30 to 50 sqm).
S&F in repair 70 Watt LED street light fittings made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by the Engg-in-Charge. Make Crompton Model No LFLN-120-CDL/60-M or equivalent.
S&F in repair 90 Watt LED street light fittings made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by the Engg-in-Charge. Make Crompton Model No LFLN-120-CDL/60-M or equivalent.
S&F in repair LED Flood lights 50 Watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by the Engg-in-Charge. Make : CG/Havells/Syska
S&F in repair LED Flood lights 120 Watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by the Engg-in-Charge. Make : CG/Havells/Syska
S&F in repair LED Flood lights 200 Watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by the Engg-in-Charge. Make : CG/Havells/Syska
Supply and installation in repair of 3 Pole power contractor, type MNX 110 having 2 NO +2 NC contacts and cat part no CS94137 complete all as specified and directed by the Engg-in-Charge. Make Schneider /Havells/L&T.
Supply and installation in repair of Analog Time switch , 240 Volt AC , 50 Hz -01 Nos complete all as specified and directed by the Engg-in-Charge. Make L&T Cat No J648B1 or equivalent in Havells/Schnider
S&F in repair 3.5 M long post top light pole aesthetically designed decorative hot dipped galvanised mild steel step pole with grey powder finish, plasma cut & duly chamfered opening window of 300x110 mm for terminal connections & mounting accessories . Window cover is fitted with allen screws to the pole complete all as specified and directed by the Engg-in-Charge. Make : Havells or equivalent in Philips/CG
S&F 35W post top lantern having protection IP 65/66 complete all as specified and directed by the Engg-in-Charge. Make Havells (Item code No. VICTORIAPT35WLED730 PSYMTOTG) or equivalent in Philips/CG
S&F pole base cover aestetocally designed decorative pole base cover, enhancing the apearance of the pole complete all as specified and directed by the Engg-in-Charge. Make : Havells or equivalent in Philips/CG. Note- The cost of excavation and PCC 1:3:6 , type C-1 for foundation required for post top light pole is deemed to be included in the quoted rate
M&L for disconnecting all electric LT Supply from timer panel of High mast and lowering down the high mast light fitting set by using motor/manually for repair/replacement work and change the unsv/worn out parts after repair works completed check the serviceability of high mast and remove all dust/nest and greasing the rope/motor/gear assembly for proper functioning before raising up in the the original position complete all as specified and directed by the Engg-in-Charge.
Supply only stainless steel rope 6mm dia complete all as specified and directed by the Engg-in-Charge.
Supply only D clamp including nut bolt and washers complete all as specified and directed by the Engg-in-Charge.
Supply only 6 Sqmm 5 Core flexible aluminum cable complete all as specified and directed by the Engg-in-Charge.
Supply only 1.5 HP motor 3 Ph 440 volt 50 hz AC supply for operating the stainless steel rope through gear assembly complete all as specified and directed by the Engg-in-Charge.
Supply only gear assembly used for operating the stainless rope for lowering down the high mast fitting complete all as specified and directed by the Engg-in-Charge.
Material and labour for disconnecting burnt end or portion of cable removing the cable from loop including necessary excavation & earth work in soft/loose soil relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals including fixing of new lugs for 50 Sqmm 3½ / 4 to 400 Sqmm of LT cable to pole / main switch complete all as specified and directed by the Engg-in-Charge.
M&L for disconnecting existing LED street lights/flood lights from PCC/GI poles for repairing of unserviceable LED street light fitting of any type / make of 45-60 watt capacity by replacing UNSV compact LED electronic driver, broken tempered glass, silicon gasket, led blubs ,FMSPD suitable to operate on 150 to 277 Volt 50 / 60 Hz AC supply and reinstall at same location/place after repair work complete all as specified and directed by the Engg-in-Charge.
All as per Srl Item No.43 above but Street Light of Cap 70/120 watt complete all as specified and directed by the Engg-in-Charge.
All as per Srl Item No.43 but Street Light of Cap 150/250 watt complete all as specified and directed by the Engg-in-Charge.
All as per Srl Item No.43 but flood lights 200 watt complete all as specified and directed by the Engg-in-Charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
dee vee enterprises (BID ID -3158914)
Rajindera Enterprises (BID ID -3158167)
Vijay Electricals (BID ID -3153950)
MV Engineers And Contractors (BID ID -3159020)
Ridhi engineers and builders (BID ID -3154214)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .