Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹21.5 L+₹99,203 (4.84%)Rejected-AOC | L2 | Rejected-AOC Being other than L1 | |
| 3 | L3₹21.9 L+₹1.4 L (6.79%)Rejected-AOC 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L3 | Rejected-AOC Being other than L1 | |
| 4 | L4₹21.9 L+₹1.4 L (6.95%)Rejected-AOC STREET NO 10 MALLOMAZRA ROAD BHAKHRA ENCLAVE PATIALA PB | PATIALA | PUNJAB | 140401 | L4 | Rejected-AOC Being other than L1 | |
| 5 | L5₹36.2 L+₹15.7 L (76.8%)Rejected-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L5 | Rejected-AOC Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹89,000
Closing Date
8 Jun 2024, 6:00 pmClosed
Shri Ankur Lohiya, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH SANGRUR ROAD PATIALA CANTT
As per tender documents
2024_MES_653422_1
GE(S)/PAT/T-04/2024-25
Open Tender
Civil Works
Item Rate
240 days
Sangrur
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹89,000
Yes
22 Jul 2024
11 May 2024
10 Jun 2024
11 May 2024
8 Jun 2024
25 May 2024
11 May 2024 - 18 May 2024
Amount
'Notes: (i) Please refer Schedule 'A' Notes of tender documents.
M&L in replacement PVC flat twin core sheathed 1100 volts grade aluminium high quality LT cable of size 6 sqmm twin core complete all as specified and directed.
M&L in replacement PVC flat twin core sheathed 1100 volts grade aluminium high quality LT cable of size 4 sqmm twin core complete all as specified and directed.
M & L for PVC insulated unsheathed FRLS cables single core multi stranded copper conductor cable for repairs in existing conduits of size 1.5 sq mm as in replacement in burnt/defective circuits complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including connecting to junction box and fixing of light fitting to existing GI bracket with and including steel clamps duly painted complete accessories suitable for fixing to the RCC LT Pole of 9 mtr complete all as specified and directed.
All as per srl item no-04 but 60 Watt complete all as specified and directed.
All as per srl item no-04 but 90 Watt complete all as specified and directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete with all accessories required for fixing arrangements all as specified and directed.
All as per srl item no-07 but 100 Watt complete all as specified and directed.
Supply and fixing post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete and incl cost of masonary work for fixing of light on gate pillars on suitable size GI tubing duly silver painted incl colouring/white wash of masonary surface for matching of existing colour/surface all as specified & directed.
S&F Single Phase SMC Junction box suitable for mounting on LT RCC pole of 9 mtr long, box having Al busbar 20 Amp rating with 6 Amp MCB ('B' series) control, mounted on insulators with 2 clamps of copper strip for earthing of the armoured of the cable complete with making holes for connecting cables etc nuts bolts etc front openable hinged cover suitable for mounting on steel clamps nut bolt etc pvc adopters and PVC hose pipe upto cable trench for incoming and outgoing cables, factory made duly painted with powder coating process complete as specified and directed.
S&F DBs sheet metal enclosure 2 ways for fixing of SPN MCB on pole/wall mounting all as specified and directed.
S&F in replacement of MCB SPN 6-32 Amps 230 volts 'C' Series complete all as specified and directed.
M&L for servicing of solar street light fitting 12 V of 45 Watt complete all as specified and directed.
S&F Battery 12V 150 AH suitable for solar street light fitting, IN REPLACEMENT complete all as specified and directed.
M&L for GI pipe(light grade) bracket of 25 mm dia size of 1.2 mtr long bent to shape as required for fixing of LED street light fittings including fixing with steel clamps duly painted and accessories etc all as specified and directed.
All as per srl item no-04 but 40 mm dia complete all as specified and directed.
All as per srl item no-04 but 50 mm dia complete all as specified and directed.
Supply & Fix in replacement of PVC Conduit of size 20 mm incl all connected accessories (bends, clamps, PVC union & screws etc) incl disconnecting of existing cables/wires from LED fitting/junction box and inserting the same wire in the conduits and making connections complete all as specified and directed.
Dismantling of ceiling fan 1200/1400 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire ISI marked including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed, as per the direction of Engineer-in-Charge complete all as specified and directed.
All as per item No 19 here- in- before but exhaust fans up to and incl. 230/300 mm sweep complete all as specified and directed.
All as per serial item No 19 here-in-before but exhaust fans of sweep more than 300 mm and upto 480 mm complete all as specified and directed.
All as per serial item No 19 here-in-before but wall fans fans of sweep up to 450 mm complete all as specified and directed.
Replacement of gun metal bush suitable for ceiling fans, exhaust fans and wall fans of any makes/size complete all as directed.
Replacement of ball bearing of suitable for ceiling fans/exhaust fans /wall fans of any size/make complete all as specified and directed..
Replacement of capacitor 2.5 mfd, 230 Volts + 5% dry type complete all as specified and directed.
All as per item No 25 here-in-before but 3.15 mfd complete all as specified and directed.
All as per item No 25 here-in-before but 4 mfd complete all as specified and directed.
Replacement of rubber reel, nut and bolts, spring washer, split pin for ceiling fans of any Make/Size, complete all as specified and directed.
S&F Fan regulator, electronic step type complete all as specified and directed.
Taking down ceiling fan /wall fans (any size, make, type) from any position, opening for and including greasing, cleaning, complete overhauling including split pins, body/blade screws , refixing in its original position and testing on full speed complete all as specified and directed incl provn of new cable flexible of copper conductor twin core, PVC insulated of size 23/.0076 ,750 mm long and one run of earth wire and tapping rubber insulating complete all as specified and directed.
Taking down exhaust fan (any size, make, type) from any position, opening for and including greasing, cleaning, complete overhauling including split pins, body/blade screws , refixing in its original position and testing on full speed complete all as specified and directed incl provn of new cable flexible of copper conductor twin core, PVC insulated of size 23/.0076 ,750 mm long and one run of earth wire and tapping rubber insulating complete all as specified and directed.
Replacement of ceiling fan blade (Set of 3) of 1200 sweep ceiling fan including nuts, washers etc complete all as specified and directed suitable for any make of fan.( white colour) complete all as specified and directed.
All as per Serial item No 32 here-in-before but for 1400 mm sweep ceiling fan complete all as specified and directed.
Turning,grinding and making good seat to ball bearing in proper position (Ball bearing not included in this item ) complete all as specified and directed.
Supply and connecting flexible copper wire Cable flexible of copper wire 0.5 sq mm (white clolour) complete all as specified and directed.
Supply & fixing as in repair louvers made out of 0.63mm galvanised iron sheet for exhaust fan of any make and size upto 300mm complete all as specified and directed.
Supply & fixing as in repair louvers made out of 0.63mm galvanised iron sheet for exhaust fan of any make and size above 300mm and upto 450mm complete all as specified and directed.
Replacement of PVC canopy (upper/bottom) for ceiling fan of any make and size complete all as specified and directed.
Supply & fixing down rod for ceiling fans made out of MS pipe 15mm bore medium grade 45 cm long duly threaded, holes drilled and spray painted with synthetic enamel paint complete all as specified and directed.
Spray painting on outside body of the ceiling fan incl blades any size with synthetic enamel paint (white colour) including scrapping existing paint and incl writing MES NO with black paint complete all as specified and directed.
Spray painting on outside body of the exhaust fan incl blades any size with synthetic enamel paint (smoke gray colour) including scrapping wxisting paint and incl writing MES NO with black paint complete all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light fan socket or power) complete along with fittings such as switches, ceiling roses, Bell Push, Socket, Pendants, regulators, Tube/LED fittings, Square LED, Bulk Head and other Kits & fittings/conduit from surface /wall . Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location. (Note :- Serviceable fitting / fixtures will be reused in the work complete all as specified and directed.
Taking down un-serviceable main switch, DB’s insulators, DB for MCB, MCB etc of any type and any capacity and further disposal including making good the disturbed surface and matching the colour of wall with the existing colour wash / paint / distemper wherever required (as per the existing ) complete all as specified and directed.
M&L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit of suitable size (not less than 20 mm) on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLS PVC insulated unsheathed stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable as earth continuity conducter to common earth and connected to earth dolly, complete all as specified, for the fone light/fan point controlled by one 1-way switch complete all as specified and directed.
All as per item No 44 here-in-before but one light point controlled by two 2-way switch complete all as specified and directed.
All as per item No 44 here-in-before but one 3/5 pin socket outlet, 5 Amp on independent board complete all as specified and directed.
All as per item No 44 here-in-before but one 3/5 pin socket outlet, 5 Amp on same board complete all as specified and directed.
All as per item No 44 here-in-before but one bell /buzzer point controlled by one push button on independent board complete all as specified and directed.
M&L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 4.0 Sq.mm (nominal area ) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLS PVC insulated unsheathed stranded copper conductor 4.0 Sq.mm (nominal area ) single core cable as earth continuity conducter to common earth and connected to earth dolly, complete all as specified and directed. (For AC and Geyser)
M&L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLS PVC insulated unsheathed stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable as earth continuity conducter to common earth and connected to earth dolly, complete all as specified and directed.
Dismantling/Taking down existing unserviceable sub main wiring from batten / conduit of any size all as directed. Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location complete all as specified and directed.
M &L for sub main surface wiring with PVC insulated unsheathed copper conductor cable of size two runs of 10 Sqmm single core through and including concealed rigid nonmetallic PVC conduit of suitable size (Not less than 25 mm dia) in wall and surface of ceiling including 10 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly including making good the disturbed potion of wall complete all as specified and directed. (Note :- Two run of 10 Sqmm copper cable one run of 10 Sqmm copper cable and PVC conduit will be measured as a single length)
M &L for sub main surface wiring with PVC insulated unsheathed copper conductor cable of size two runs of 6 Sqmm single core through and including concealed rigid nonmetallic PVC conduit of suitable size (Not less than 25 mm dia) in wall and surface of ceiling including 6 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly including making good the disturbed potion of wall complete all as specified and directed. (Note :- Two run of 6 Sqmm copper cable one run of 6 Sqmm copper cable and PVC conduit will be measured as a single length)
S&F Switch Modular type, 6 Amp, 240 Volts , one way complete fixed as complete all as specified and directed.
S&F Switch Modular type, 6 Amp, 240 Volts , Two way complete fixed as complete all as specified and directed.
S&F Switch Modular type, 16 Amp,240 Volts , one way complete fixed as complete all as specified and directed.
S&F Socket outlet, Modular type, 6 Amp complete fixed as complete all as specified and directed.
S&F Socket outlet, Modular type, 6&16 Amp complete fixed as complete all as specified and directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB IN REPAIR complete all as specified and directed.
S&F Bell Push, Modular type, 6 Amp complete fixed as complete all as specified and directed.
S&F Fan regulator, modular type electronic step type complete fixed as complete all as specified and directed.
S&F ceiling rose surface bakelite two to three terminal 65x50 mm complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified & directed.
S&F Tube light fittings LED type 1x20 Watt 4 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable all as specified & directed.
S&F Tube light fittings LED type 1X10 Watt, 2 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable all as specified & directed.
S&F LED bulk head,10 W complete all as specified & directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as directed.
S&F bell ding dong operating on AC 230 volt single phase complete all as specified and directed.
S&F MCB DB SPN 4 Way with acrylic double door complete all as specified and directed.
S&F MCB DB SPN 8 Way with acrylic double door complete all as specified and directed.
S&F including flushing in wall MCB distribution board vertical TPN 4 way 415 Volts AC double door type sheet steel phosphotised powder painted with bus bar neutral earth bar including provision of MCB TPN, FP 100 Amp conforing to IP 43 as incomer all as complete specified and directed.
S&F MCB 4 TPN 63 Amp 415 volt with breaking capacity of 16 KA complete all as specified and direceted.
S&F MCB 4 TPN 100 Amp 415 volt with breaking capacity of 16 KA complete all as specified and direceted.
S&F MCB SPN 240V 40 Amps C series 10 KA complete all as specified and direceted.
S&F MCB SP 240V 6 to 32 Amps C series 10 KA complete all as specified and direceted.
Taking Down the KWH meter along with wooden board/DB after removing all electrical connection complete all as directed by Engineer in Charge.
Refixing & connecting the same or serviceable KWH energy meter after wiring complete all as directed by Engineer in Charge.
S&F Sheet metal enclosure factory made of size 20cm x 25cm x 12.5 cm deep box made out of 2mm thick ms sheet with double door with locking arrangement , epoxy power coated holes drilled for cable entries suitable for accomodating electric energy meter including brick/cement works as per site requirement includiing flushing the box in walll and making good the disturbed portion of wall /surface complete all as specified & directed bby Engr in charge.
Taking down old U/S aluminium service cable of any size from trenches/pipe/floor/walls complete all as specified.
Supply laying jointing aluminium service cable 10 sqmm 2 core fixing on wall/ducts etc including necessary fixing arrangement such as cable lugs glands etc complete after removing/taking out extg unsv cable to the entire satisfaction of Engr in Charge.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2 mtr deep below ground level with top edgw of the plate not less than 1.4 mtr below normal ground level , connected earth wire 4 sqmm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit in PCC(1:3:6) type C-1 cast iron frame 50mm thick pre cast RCC(1: 1 1/2:3) nominal mix cover slab reinforced with 8 mm dia mild steel deformed bar 15cc and suitable handle of 10 mm Dia round bar including necesary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc 50m and funnel with watering pipe wire mesh copper lugs etc GI protection pipe of size 15 mm bore including testing complete all s specified & directed by Engr in Charge.
S&F Modular white cover plate with frame 1 module complete all as specified and directed.
S&F Modular white cover plate with frame 2 module complete all as specified and directed.
S&F Modular white cover plate with frame 3 module complete all as specified and directed.
S&F Modular white cover plate with frame 4 module complete all as specified and directed.
S&F Modular white cover plate with frame 8 module complete all as specified and directed.
S&F Modular metal flush box 1/2 module complete all as specified and directed.
S&F Modular metal flush box 3 module complete all as specified and directed.
S&F Modular metal flush box 4 module complete all as specified and directed.
S&F Modular metal flush box 8 module complete all as specified and directed.
S&F Modular white blank plate complete all as specified and directed.
Servicing of installed window type Air conditional of any make 1.5/2.00 TR ton capacity including taking down , dismantling from grill , taking out air conditioner , removing all electrical components, cleaning with brush , condenser, washing with presure water , oiling moving parts and reassembling complete all as specified and directed.
Servicing of installed Split Air conditioner of any make 1.5/2.0 TR capacity indoor and out door units including taking down , dismantling from grill , taking out air conditioner , removing all electrical components, cleaning with brush , condenser, washing with presure water , oiling moving parts and reassembling complete all as specified and directed.
Carrying out leak check and rectifrying/arresting the same by brazing and recharging gas commissioned and testing to entire satisfaction of Engr-in-charge incl gas for 1.5/2.0 TR capaity. Recharging of gas F-22 complete including testing of leakage and testing the AC unit of any capacity and type for satisfactory performance complete all as specified and directed.
Supply and replacement of defective front grill decorative suitable for window type AC's 1.5/2.00 ton capacity of any make as per the original model of air conditionercomplete all as specified and directed.
Supplying and replacement of operating knobs of window type AC's of any make of make and model as per the existing model/size complete all as specified and directed.
Supplying and replacement of air filter as per original sample complete all as specified for AC's 1.5/2.0 Ton of any type/any make complete all as specified and directed.
Taking down unserviceable water cooler 40/80 litre cap. from any position and removing unserviceable burnt sealed unit ( compressor ) from cooler and S & F new compressor unit and testing on required pressure and installing cooler at its original posn complete all as specified and directed. Note : Cost of filling with refrigerant gas is included in unit rate of this item.
Taking down unserviceable water cooler 150 litre cap. from any posn. and removing unserviceable burnt sealed unit ( compressor ) from cooler and S & F new compressor unit and testing on required pressure and installing cooler at its original posn. all as spec ified and directed. Note : Cost of filling with refrigerant gas is included in unit rate of this item.
Supply & replacement of thermostat switch suitable for water coolers including knobs, plate and screws complete ass as specified and directed.
Supply and replacement running capacitor suitable for water cooler 40/80/150 ltr capacity complete all as specified and directed.
Supply & replacement of starting relay assembly including replacement of cover and clips suitable for water coolers of capacity 150 ltr complete as as specified and directed.
Supply & replacement of starting relay assembly including replacement of cover and clips suitable for water coolers of capacity 40/80 ltr complete as as specified and directed.
Supplying and replacement of over load protector for Water cooler 150 litre cap. complete all as directed.
Supplying and replacement of over load protector for Water cooler 40/ 80 litre cap. complete all as directed.
Supplying and replacement of starting capacitor for Water cooler 150 litre cap. complete all as directed.
Supplying and replacement of starting capacitor for Water cooler 40/80 litre cap. complete all as directed.
Taking down unserviceable fan motor of water cooler of 150 ltr capacity and rewinding with suitable size of super enamelled copper winding wire including replacement of bushes, rubber mounting, clips and commissioning and testing complete all as specified and directed complete all as specified and directed.
Taking down unserviceable fan motor of water cooler of 40/80 ltr capacity and rewinding with suitable size of super enamelled copper winding wire including replacement of bushes, rubber mounting, clips and commissioning and testing complete all as specified and directed complete all as specified and directed.
Taking down old unserviceable fan motor supply and fix new fan motor suitable for water cooler of cap 150 ltr capacity complete all as specified and directed.
Taking down old unserviceable fan motor and supply and fix new fan motor suitable for water cooler of cap 80/40 ltrs capacity complete all as specified and directed.
Supply and replacement water tap 15 mm dia, self closing, chromium plated push cock heavy duty (as per existing) complete all as specified and directed.
Cleaning of water cooler body of capacity 40/80/150 ltrs internally and externally including scraping and removing all scales and dirt etc. Repair to body to stop leakage and replacing unserviceable screws, nut & bolts etc. spray painting of water cooler with synthetic enamel paint hammer tone paint including preparation of surfaces and applying red oxide primer all as directed at site.
Supplying and replacement PVC flexible copper cable 3 core 40/0.0076 length complete all specified and directed
Carrying out leak check and rectifying/arresting same by brazing to copper tubing and recharging refrigerant gas commissioning and testing to entire satisfaction of engineer-in-charge for water cooler including cost of gas to be filled complete all as specified and directed.
Taking down unserviceable refrigerator 300/310 ltr capacity from the site ,removing unserviceable burnt sealed unit (compressor) from the refrigerator and supply & fix new compressor including testing on required pressure and fix in original position complete all as specified and directed.
Taking down unserviceable refrigerator 165to280 ltr capacity from the site ,removing unserviceable burnt sealed unit (compressor) from the refrigerator and supply & fix new compressor including testing on required pressure and fix in original position complete all as specified and directed.
Taking down unserviceable Deep freezer 300/320 ltr capacity from the site ,removing unserviceable burnt sealed unit (compressor) from the refrigerator and supply & fix new compressor including testing on required pressure and fix in original position complete all as specified and directed.
Recharging of gas and testing and rectifying the leakage from system of refrigerator/ deep freezers complete all as specified and directed.
Supply & fixing as in repairs of Refrigerator door (plastic) complete with tension spring as per original complete all as specified and directed.
Supply & fixing as in repairs of Deep freezer door (plastic) complete with tension spring as per original complete all as specified and directed.
Supply & fixing as in repairs lce tray plastic as per original complete all as specified and directed.
Supply & fixing as in repairs fruit/ vegitable tray as per original complete all as specified and directed.
Supply and replacement of pigmy lamps (bulb) of refrigerator complete as per existing complete all specified and directed
Supply & fixing as in repairs door liner (plastic) of refrigerator of any capacity as per original complete all as specified and directed.
Supply & fixing as in repairs fruit/vagitable glass cover complete as per original complete all as specified and directed.
Supply & fixing as in repairs door megnetic gasket complete as per original make for refrigerator 300/310 ltr capacity complete all as specified and directed.
Supplying and replacement relay box for any capacity refrigerator complete all specified and directed.
Supplying and replacement of over load protector for any capacity refrigerator complete all as specified and directed.
Supplying and replacement of door lock with two keys as per original specification complete all as specified and directed.
M&L for spray painting of refrigerator with synithetic enamel paint over a coat of red oxide primer after preparation of surface of refrigerator coapacity 165 to 300 ltr of any make /model complete all as specified and directed.
M&L for replacement of PGI sheet 20 gauge approximately by gas welding duly cut and bend to shape to match existing size and shape and making good the dameged insulation by filling glass wool (approximate 1 kg) complete all as specified and directed.
M&L for replacement by cutting shreading of corroded rusted sheet metal portion all arround the body including welding as per existing size sheet and refabrication the same portion and refixing by welding (Tinkering ) and matching the same as existing by metal paste /putty and painting with one coat of primer red oxide and two coats of supper enamelled paint complete all as specified and directed.
Taking down desert cooler fixed at any position cleaning internally and externally by scraping all scales dirt etc and repair to desert cooler to stop any type of leakage, tightening & replacing of screws, nuts and bolts etc all as directed including necessary oiling and greasing of fan and water lifting pump complete all as specified and directed.
Supply and fix in replacement of water lifting pump, 230 volt 50 C/S single phase suitable for desert coolers complete all specified and directed.
Supplying and replacement wool pads of suitable size and providing wire netting of GI wire 1.4 mm dia 25 mm mesh for holding pads complete all specified and directed.
Supplying and replacement high density polythene pipe 15 mm dia for desert coolers complete all specified and directed.
Supply and replacement for replacement of capacitor 4 mfd suitable for desert cooler complete all specified and directed.
Dismantling and taking out old, unserviceable fan motor from the desert cooler and rewinding with supper enamel winding copper wire of suitable size varnishing etc including replacement of bushes, assembling testing and refixing in existing position all as specified and directed.
Labour only for servicing of DG Sets of following capacity complete all as specified and as directed for DG cum pump 4.6 KVA complete all as specified and directed.
same as item 141 but for DG set of 10 KVA complete all as specified and directed.
same as item 141 but for DG set of 30 KVA complete all as specified and directed.
same as item 141 but for DG set of 62.5 KVA complete all as specified and directed.
Supply and top up the coolant K Cool super plus-25/75 complete all as specified and directed.
Supply and changing the engine oil of suitable grade including drain out existing used oil complete all as specified and directed.
Supply only the Diesel filter in DG set of 62.5 KVA capacity complete all as specified and directed.
Supply only the Oil Filter in DG set of 62.5 KVA capacity complete all as specified and directed.
Supply only the Air cleaner Filter in DG set of 62.5 KVA capacity complete all as specified and directed.
Supply only the Air cleaner hose pipe with clamp in DG set of 62.5 KVA capacity complete all as specified and directed.
Supply only the Radiator hose pipe with clamp in DG set of 62.5 KVA capacity complete all as specified and directed.
Supply only the Fan belt in DG set of 62.5 KVA capacity complete all as specified and directed.
Supply only the Diesel filter in DG set of 30 KVA capacity complete all as specified and directed.
Supply only the Oil Filter in DG set of 30 KVA capacity complete all as specified and directed.
Supply only the Fan belt in DG set of 30 KVA capacity complete all as specified and directed.
Supply only the Diesel filter in DG set of 10/4.6 KVA capacity complete all as specified and directed.
S&F Dynamo Rotor assembly of 30 KVA DG complete all as specified and directed.
S&F Dynamo rectifier assembly of 30 KVA DG complete all as specified and directed.
S&F Dynamo coutout assembly of 30 KVA DG complete all as specified and directed.
S&F Dynamo starter assembly of 30 KVA DG complete all as specified and directed.
S&F Dynamo carbon (Set of 2 Pcs) of 30 KVA DG complete all as specified and directed.
S&F Self clutch assembly of 30 KVA DG complete all as specified and directed.
S&F Self pinion assembly of 30 KVA DG complete all as specified and directed.
S&F Self solenoid switch assembly of 30 KVA DG complete all as specified and directed.
S&F Self Bandan Assembly of 30 KVA DG complete all as specified and directed.
S&F Self carbon brush (set of 4 pcs) of 30 KVA DG complete all as specified and directed.
S&F Self carbon rocker assy of 30 KVA DG complete all as specified and directed.
Repair to Battery charger suitable for 12 V DC battary complete all as specified and directed.
Supply and fix battery of capacity 80 AH complete all as specified and directed.
Supply and fixing Battery lead with terminal cable of size 19 swgx72" long set complete all as specified and directed.
Servicing and caliberation of Auto Main Failure (AMF) Panel complete all as specified and directed.
Gurcharan Singh Enterprises
AGGARWAL & CO
gurchan singh & sons.
NARINDER KUMAR SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .