| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC SPECIAL 1 INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 | JODHPUR | RAJASTHAN | 342003 | L1 | Accepted-AOC Ok | |
| 2 | L2₹28.6 L+₹44,520 (1.58%)Rejected-Finance B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹28.7 L+₹54,720 (1.95%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹29.9 L+₹1.8 L (6.34%)Rejected-Finance INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹35.9 L+₹7.8 L (27.6%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
15 Feb 2023, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
REPAIR/ REPLACEMENT OF UNSERVICEABLE SPARES OF COOLING TOWERS, AHUS, PUMPS AND REWINDING OF ITS MOTORS AND REPAIRING OF NORMAL OUTDOOR UNIT WITH VRF BASED OUTDOOR SYSTEM AND CONNECTED MISC E/M WORKS AT BASE HOSPITAL DELHI CANTT-10
2023_MES_575580_1
GE/BH-108/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D category c(i)
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSPITAL DELHI CANTT
₹94,000
Yes
24 Mar 2023
18 Jan 2023
17 Feb 2023
18 Jan 2023
15 Feb 2023
2 Feb 2023
Amount
Taking out the filter from AHU from 1000 CFM to 13000 CFM cleaning coil with suitable chemical and jet of water pressure with pump and remove all the scale and foreign material deposited in side the coil followed with air pressure to sweep up all the particles and ensure thorough flow of air over the cooling coil complete all as specified and directed for any capacity of AHU and refixing the air filter after cleaning complete all as specified and directed.
M&L for repairing/ servicing AHU Fan Motor of following capacity, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enamelled copper winding of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end & non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed:-
5 HP/ 5.5 HP AHU fan motor, Make-Kirloskar, Crompton Greaves, Model-1622 TOP
7.5 HP AHU fan motor, Make- Kirloskar, Bharat Bijlee, ABB, Model-KI 1325 & M2BA 132S4
10 HP AHU fan motor, Make- ABB, Model-M2BA 132M-4, SMC-4 & HX-132SM64
Taking up or down 40 mm bore MS pipe from trenched/ wall surfaces or in any position complete all as specified and as directed.
All as per item No 3.00 here-in-before but of pipe 50 mm bore.
All as per item No 3.00 here-in-before but of pipe 65 mm bore.
All as per item No 3.00 here-in-before but of pipe 80 mm bore.
All as per item No 3.00 here-in-before but of pipe 100 mm bore.
All as per item No 3.00 here-in-before but of pipe 125 mm bore.
All as per item No 3.00 here-in-before but of pipe 150 mm bore.
Supply and lay MS pipe condenser water or cooling tower piping of MS 'C' class 40 mm dia confirming to IS-1239 and IS- 3589 both revised till date as required and as specified and complete with bends, reducers tees, supports vibration pipe supports, structures shall be painted with 2 coats of synthetic enamel paint over a coat of red oxide primer including testing complete all as specified & directed.
All as per item No 10 here-in-before but of pipe 50 mm bore.
All as per item No 10 here-in-before but of pipe 65 mm bore.
All as per item No 10 here-in-before but of pipe 80 mm bore.
All as per item No 10 here-in-before but of pipe 100 mm bore.
All as per item No 10 here-in-before but of pipe 125 mm dia.
All as per item No 10 here-in-before but of pipe 150 mm bore.
M&L for taking out Cooling Tower Motor of following capacity, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enamelled copper winding of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end & non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed:-
2 HP Cooling Tower Motor
3 HP Cooling Tower Motor
5 HP Cooling Tower Motor
Dismantling of existing cooling tower with cutting and removing of existing MS pipeline and valves complete all as specified and directed.
Supply, installation, testing, commissioning of Cooling tower Capacity - 175 TR cooling tower Induced Draft Counter Flow Type, complete with accessories complete all as specified and directed by the Engr-in-Charge. Note: Heat rejection- 656250 Kcal/Hr, Water flow rate - 2625 LPM, Hot water temperature 36.4 degree Celsius, Cold water temperature 32.2 degree Celsius, Design wet bulb temperature - 28.3 degree Celsius, Height of cooling tower - 3300 MM, Length of cooling tower - 3000 MM, Fill depth - 600MM, Wetted Surface area - 1312 Meter Square, Static Weight of cooling tower - 2600 Kgs, Design range - 4.2 degree Celsius, Design approach - 3.9 degree Celsius, Fill flute size - 12 MM, Fill Honey comb type, cooling tower fan - 01 No, fan diameter / Airflow - 1500MM/43925 CFM, Fan RPM - 960 RPM
Material of Construction:- Casing - FRP, Fill - VIRGIN PVC, Eliminators - PVC, Supporting Structures - MS HDG, Cold water basin - FRP, Hot water distribution - PVC header, Fan blades - cast aluminium alloy, Fan hub - Cast aluminium alloy, Evaporation loss % of total water in circulation - 0.75%, Drift Loss % of total water in circulation - 0.05%, Total make up water % of total water in circulation - 0.8%, Hot water inlet size - (2 X 125)MM, Cold water out let size- 150MM, Over flow connection - 50MM, Drain connection - 50 MM, Make -Up connection - 15 MM, MOTOR:- Motor type - TEFC, direct driven, Motor Current Characteristics - 415V/50 Hz/3 Ph, Motor capacity - 7.5 HP, Motor rating - 5.5 KW, Motor RPM - 960, Motor Make - Oswal/Sohal/Kirloskar, MS Base Frame for cooling tower. complete all as specified and directed. Make:- Paharpur, Mihir,Polo, Advance, Delta
Supply only, in replacement heating element capacity 3 KW, ISI marked and making electric connections and taking down old unserviceable heating elements, complete all as directed. Make : Daspass/ Theata/ Indfoss
S&F in repair 50mm thick box type Pre-Filter (EU-4) Synthetic media type flange type (non woven type ) efficiency - 90% down to 10 micron with complete all fitting for AHU and 50 mm wg static pressure with rod support fabrication with GI/Aluminium frame, suitable for AHU of make fedders lloyd all complete as specified & directed. Make for filter :- Athlete/ AAF/ Fredenberg
S&F in replacement Absolute HEPA filter of size 830 x 550 x 690mm having rated flow 2000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed.
S&F in replacement Absolute HEPA filter of size 610x610x305mm having rated flow 2000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed.
S&F in replacement Absolute HEPA filter of size 610x305x305mm having rated flow 1000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed.
S&F in replacement Air filter for Air cooled type package type suitable for 22 TR air Conditioners of material Non woven polyster media enclosed by HPDE mesh filter size should be (H x w) 1250 mm x 658 mm of grade G3 complete all as specified and directed.
S&F in repair Air filter for Air cooled type package type suitable for 11 TR air Conditioners of material Non woven polyster media enclosed by HPDE mesh filter size should be (H x w) 828 mm x 577 mm of grade G3 complete all as specified and directed.
S&F in repair Air filter for Air cooled type package type suitable for 16.5 TR air Conditioners of material Non woven polyster media enclosed by HPDE mesh filter size should be (H x w) 933mm x 457mm of grade G3 complete all as specified and directed.
Excavation in trenches not exc 1.50 mtr wide or 10 sqm on plan, 1.50 mtr for manholes & sewage lines, drain, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and directed.
M&L for removing excavated soil to a distance exc 500 mtr and not exc 1.0 km and depositing where directed complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6M mean radius built in cement mortar 1.6 including demolition of old brick complete all as specified and directed.
M&L rendering 15mm thick in cement mortar 1.4 on other than fair faces of brick surfaces of walls finished the surface fair and even without using extra cement complete all as specified and directed.
Supply & charge the refrigerant R - 407 Gas complete all as specified and directed. (Make:- Mafron/ Freon/ Floron)
Supply & charge the refrigerant R - 410 Gas complete all as specified and directed. (Make:- Mafron/ Freon/ Floron)
Supply, assembly and erection in replacement 24 Gaug GI sheet with C & SS rectangular/ square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete including necessary MS Channels, gurder supports as approved by Engr-in-Charge including making of hole in any type of wall and making good with plastering work, masonry work and necessary MS channel supports complete all as specified and directed.
Supply & erection in replacement 25 mm thick nitrile duct thermal insulation foil, non-fibrous, fire retardant, closed cell, tri- dimensional, chemically cross linked polyethylene foam, confirm to class O' for fire propagation and class 1 for surface spread of flame & factory laminated aluminium foil complete all as specified and as directed.
Supply, installation, in repair including testing and balancing of volume control dampers powder coated extruded aluminium construction Gravity based complete all as specified and as directed.
Supply and fixing fire proof double layered canvas cloth connection for AHU outlet including inspection opening complete with flanges made out of 22 GSS Sheet on both side for connection to AHE and duct complete with nuts, bolts complete all as specified and directed.
M&L for insulation of 40mm bore MS pipe with PUF slab 30 mm thick with applying bituminous compound and GI cladding with 26 guage GI sheet etc complete including taking down existing PUF insulation all as specified and directed.
All as per item No 40 here-in-before but of pipe 50 mm bore.
All as per item No 40 here-in-before but of pipe 65 mm bore.
M&L for insulation of 80mm bore MS pipe with PUF slab 40 mm thick with applying bituminous compound and GI cladding with 26 gauge GI sheet etc complete including taking down existing PUF insulation all as specified and directed.
S&F in replacement of ball bearing NU205EP with metal housing complete all as directed. Make : TATA/ SKF/ NBC/ MNR
S&F in replacement of ball bearing P-206 with metal housing complete for AHUs of different capacity all as directed. Make : TATA/ SKF/ NBC/ MNR
S&F in replacement of ball bearing P-207 with metal housing complete for AHUs of different capacity all as directed. Make : TATA/ SKF/ NBC/ MNR
S&F in replacement of ball bearing P-208 with metal housing complete for AHUs of different capacity all as directed. Make : TATA/ SKF/ NBC/ MNR
S&F in replacement of ball bearing P-209 with metal housing complete for AHUs of different capacity all as directed. Make : TATA/ SKF/ NBC/ MNR
S&F in replacement of ball bearing No 6201, incl dismantling of old unserviceable bearing complete all as directed. Make : NBC/ SKF/ MNR/ TATA
S&F in replacement of ball bearing No 6202, incl dismantling of old unserviceable bearing complete all as directed. Make : NBC/ SKF/ MNR/ TATA
S&F in replacement of ball bearing No 6203, incl dismantling of old unserviceable bearing complete all as directed. Make : NBC/ SKF/ MNR/ TATA
S&F in replacement of ball bearing No 6204, incl dismantling of old unserviceable bearing, complete all as directed. Make : NBC/ SKF/ MNR/ TATA
S&F in replacement of ball bearing No 6205, incl dismantling of old unserviceable bearing, complete all as directed. Make : NBC/ SKF/ MNR/ TATA
S&F in repair 3 pole power contactor 415 V, type MNX 70 including NO or NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed.
S&F in repair 3 pole power contactor 415 V, type MNX 50 including NO or NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed.
S&F in repair 3 pole power contactor 415 V, type MNX 25 including NO or NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed.
Supply only in replacement of thermal over load relay range 20-33 Amps, with built in single phase preventer, direct/ separate mounting on contactors, as required, with and incl taking down of unserviceable relay and making all electric connection, complete all as directed.
All as per Srl item No 57 here-in-above but 14-23 Amps capacity.
All as per Srl item No 57 here-in-above but 9-15 Amps capacity.
All as per Srl item No 57 here-in-above but 1.4 - 2.3 Amps capacity.
M & L for painting of complete water cooled central AC plant and DX type AC plant, compressor, GI pipe lines, valve, pump sets, cooling tower, AHU pipe lines and chiller pipes etc complete all as specified and directed of the following capacity:-
3x 12 TR AC Plant
2 x 15 TR AC plant
3 x 30 TR AC plant
3 x 40 TR AC plant
S&F in replacement, of MCCB 100 Amp, 3 pole thermal magnetic release based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed.
S&F in replacement, of MCCB 200 Amp, 3 pole thermal magnetic release based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed.
S&F in replacement, of MCCB 400 Amp, 3 pole thermal magnetic release based with breaking capacity 50 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed.
S&F in replacement, of MCB 63 Amp, - pole thermal magnetic release based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed.
S&F in replacement of complete GI frame for AHU 12000 CFM Outer Skin 0.6 mm Pre-Coated GI, Inner Skin - 0.6 mm Plain GI, Frame work- Hollow Extruded AL Profile, Thickness of insulated Panels- 25 mm thick, CFC Free PUF injected (Density: 40 Kg/Cum), Material of Drain pan:- 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation. Unit Base:- G.S.S Base Channel complete all as specified and directed.
S&F in replacement of CHW COIL:- Coil casing/Blank offs- GI, Material of Tube - Copper, Tube diameter(mm/inch) - 12.7mm/1/2" O.D, Thickness of tube (SWG/mm) - 27 SWG/0.41 mm, Header Material of fins - 0.15 mm plain Aluminium, No of Fins per inch (FIP)- 11/12 complete all as specified and directed.
S&F in replacement of FILTERS:- Synthetic (non woven type), efficiency of pre-filters (EU-4)- 90% down to 10 micron suitable for 12000 CFM complete all as specified and directed.
S&F in replacement of Fan & Motor Capacity 10 HP Make:- ABB/BHARAT BIJLEE/CROMPTON Suitable for 12000 CFM complete all as specified and directed.
HONEY COLLECTION
DP Traders
KRISHANA ELECTRIC WORKS
RUCHIKA ENGG.WORKS
Iconic Engineers
AIRCOM
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .