Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC 12 NO 12 IRATTAI PILLAYAR KOVIL STREET NEAR REAL VALUE FLAT VELACHERY 733 CHENNAI TAMIL NADU 600042 | CHENNAI | TAMIL NADU | 600042 | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹39.8 L+₹2.2 L (5.82%)Rejected-AOC | L2 | Rejected-AOC HIGHER RATE QUOTED | |
| 3 | L3₹39.9 L+₹2.3 L (6.21%)Rejected-AOC | L3 | Rejected-AOC HIGHER RATE QUOTED | |
| 4 | L4₹40.5 L+₹2.9 L (7.72%)Rejected-AOC | L4 | Rejected-AOC HIGHER RATE QUOTED | |
| 5 | L5₹42.2 L+₹4.6 L (12.1%)Rejected-AOC | L5 | Rejected-AOC HIGHER RATE QUOTED |
Tender Value
₹47.3 L
EMD Value
₹94,700
Closing Date
2 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2023_MES_632393_1
8500-043/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
As per Tender document
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹94,700
Yes
17 Jan 2024
12 Dec 2023
3 Jan 2024
12 Dec 2023
2 Jan 2024
26 Dec 2023
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, flat or curved incl ridges hips valleys as in roof coverings complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated /semi corrugated steel sheet 0.50mm thick 150 GSM of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws with washers complete all as specified and as directed by Engr-in-charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel as in ridges sheet 0.50mm thick 150 GSM of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws with washers complete all as specified and as directed by Engr-in-charge.
S&F 1 mm thick Plain, galvanised mild steel sheeting in ridges,hips,valley gutters,drip and straight flashings (length and girth as fixed) with the grade of zinc coating 120 GSM fixed with self tapping screws with washers on brackets complete all as specified and as directed by Engr-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed
M&L for framed work such as grills etc with ends of bars shouldered and or riveted or forged into spike, framed guard bars and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed.
S&F wind ties for roof including securing bolts, flat iron fillets(for securing weather boarding with screw bolts and nuts) including all necessary drilling or riveting etc and similar work like brackets for valley gutters etc. for forming to Fe 410-O or Fe-310-O including painted with one soap coat of zinc chromate primer paint (including preparation of surfaces at contractor's workshop before fabrication) complete all as specified and as directed by Engr-in-Charge.
S&F mild steel as in trusses, purlin, crane rail and joist, channel angle or tee sections including all necessary cutting welding etc complete for forming to FE 410 W( Gde-E-250) quality A complete all as specified and as directed
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces incl preparation of surfaces over 10 cm width or girth complete all as specified and as directed
M&L for one coat of synthetic enamel paint on old steel surfaces incl preparation of surfaces over 10 cm width or girth complete all as specified and as directed by the Engr-in-charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed
M&L for sheet glass 3 mm thick ordinary quality and glazing with oil putty and pin in square n.exc 0.50 sqm in each pan in windows and ventilators complete all as specified and as directed
M&L for 75mm thick Cement concrete type C-1, 1:3:6 (using 20mm graded stone aggregate) as in plinth protection and paving complete all as specified and directed
S&F for glass dividing strips, 38x3 mm thick and inserted in position to confirm the design complete all as specified and as directed
Demolition of brick work built in cement mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material exc 100 mtr complete all as specified and as directed
M&L for old size brick work with fly ash bricks straight or curved on plan exc 6 m mean radius build in CM (1:6) complete all as specified and as directed Make: L&T/Lafarge/ACC/Shyam Steel Pvt Ltd
M&L for rendering 15 mm thick cement plaster in CM (1:4) on other than fair faces of brick/concrete surfaces finished and smooth without useing extra cement and using water proofing compound @ 3% by weight of cement content complete all as specified and directed. Note : WPC shall be measured and paid seperately.
Supply only integral water proofing compound complete all as specified and directed. (Makes :Pidilite Industries/ Impermo/Snowcem India Ltd/Sika)
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No 19.00 above mentioned but 6mm to 8mm dia complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removing rubbish off the premises complete all as specified and directed.
M&L for Cement concrete 100 mm thick type B- 1, 1:2:4 (using 20 mm graded stone aggregate) laid on concrete floors and pavings; laid over cement concrete subfloors etc. and finished to an even and rough surface as specified and as directed by Engr-in-Charge.
Demolition of RCC of any description and in any position not otherwise specifically provided for including (reinforcement cut as per required to facilitate demolition) and removing rubbish off the premises complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for fair finished surfaces of concrete complete all as specified and directed. .
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work for rough finished surface, not exceeding 200m thick (Horizontal or sloping complete all as specified and directed. .
M&L for RCC (Design Mix) M-25 (using 20mm graded stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. .
M&L for RCC (Design mix) M- 25 ( using 20 mm graded stone aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
S&F expanded metal cut to the length, bent to shape required and tying with and including annealed mild steel wire not less than 0.90 mm dia & weight n.exc 4.00 kg per sqm for fixing with galvanised steel staples supplied and fixed complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F PVC SWR pipes 150/160 mm bore single socketed in any length with rubber ring joint fixed to wall with steel clamps for rain water pipes complete all as specified and directed . Make : Supreme/ Finolex/Prayag
M&L for Cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) in surface channels and drains and Manholes complete all as specified and directed.
M&L for Extra for forming upto 40 cm inner girth fair finished drains or channels i.e. exc 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete lad over and including cement screed and jointed over screed bed or bedding layer of mortar 20mm thick in CM (1:6) for laying floor finish complete all as specified and directed.
M&L for Cement concrete (1:3:6) Type C2 (using 40 mm graded stone aggregates) as in foundations, filling and mass-concrete complete all as specified and directed.
M&L for welding in repairs exc 2.5 cm but n.exc 5cm in length with thickness of metal to be welded exc 20mm but n.exc 25mm complete all as specified and as directed by Engr-in-Charge.
M&L for cement concrete type C-1 1:3:6 (using 20 mm graded stone aggregate) in cills, steps, plinth courses, string courses, lacing courses, parapets, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed rounded or chamfered on edges complete all as specified and directed
M&L for preparation of new plastered surface of wall applying of two coats of Cement based paint over a coat of alkali resistant primer complete all as specified and directed
S&F mild steel screw bolts (machine made)with hexagonal or square heads at one end and screw other and each screw end to be fixed with washers and n.exc 5 cm but n.exc 10 cm long complete all as specified and directed
E/M PORTION Taking down carefully aluminium conductor point wiring (light, fan, socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified and directed
M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC heavy grade conduits (ISI) and fittings, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. .
All as per item No 40.00 above but 5 Amp socket on same board with other switches complete all as specified and directed.
All as per item No 40.00 above but 5 Amp socket on Independent board with other switches complete all as specified and directed.
M&L for wiring for socket outlet 3 pin, 15 amps on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC heavy grade (ISI) conduits and fittings, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
M&L for wiring for socket outlet 3 pin, 15 amps on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor,PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC heavy grade (ISI) conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
S&F switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed by Engr-in-Charge
S&F socket outlet 2 in 1 multipurpose 5 pin, (6 Amps) flush type controlled by one switch duly marked complete all as specified and directed by Engr-in-Charge.
S&F switch socket combination 2 in 1 multipurpose 5 pin, (6 Amps) flush type controlled by one switch complete all as specified and directed.
S&F switch socket combination 2 in 1, 6 pin, (16 Amps) flush type controlled by one switch complete all as specified and directed.
S&F ceiling rose surface bakelite 45 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified by Engr-in-Charge.
S&F stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified By Engr-in-Charge.
S&F lamp holder, polycarbonate body with back plate straight or angular suitable for batten fittings complete all as specified and directed.
S&F in repair submain two single core, 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC heavy grade conduit (ISI marked), including 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. (Note: Three runs cable and PVC conduit pipe will be measured as single unit)
S&F wall security light fittings 35 watts 230v, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65/66 including necessary connection complete with all accessories including connected with 3 core copper cable of suitable 1.5 sqmm size complete all as specified and directed.
S&F LED Flood light fitting 80 W/ 230 Volt AC out door type with thermal management in multiple optics with IP66 protection with impact and corrosion resistant with three core flexible copper conductor cable of suitable complete all as specified and directed.
S&F LED light fitting 1x9W/1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable complete all as specified and directed..
S&F LED light fitting 1x 20 W LED polycarbonate with LED tube rod light AC decorative box type 4' with driver, holder including LED tube light connecting up with with complete all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete all as specified and directed.
S&F heavy duty exhaust ventilation fan with louvers of sweep 450mm, 230 volts, with blade and frame and loures steel body, complete all as directed by Engr-in-Charge.
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed. (Note : Blank way covered by blanker proper and copper wire should be fix in MCB with suitable copper lux)
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, Double door (when MCBs to be used), tripple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed. (Note : Blank way covered by blanker proper and copper wire should be fix in MCB with suitable copper lux)
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
S&F MCB SPN 6 to 32 Amps, 'C' series 10KA, 240 Volts and to be housed in DBs complete including necessary connection complete all as specified and directed. (Note : Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating)
S&F 63 Amp MCCB 4 pole, 3 phase, 415 volt of capacity Amp, 16 KA complete with proper copper thimbles, copper reducer etc complete all as specified and directed.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25sqmmx4core laying properly in treanche incl taking down old one all as directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exc 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers n.exc 25cmin soft/loose soil complete all as specified and as directed.
Removal of excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L for sub class B bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
S&F GI Light grade 40 mm dia of size for road cross/cutting on wall floor drain etc complete all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
INDIAN CONSTRUCTION
M/S SEHGAL CONSTRUCTION
M/S BISWAS AND KUNDU CONSTRUCTION
KAZI SAHABUL ALAM
M/S N B SEN CONSTURCTION
MS ROYAL CONSTRUCTION INDEX NO 158 2010 BKP
M/S PROVAS GHOSH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .