Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹40.7 L+₹2.8 L (7.36%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹42.5 L+₹4.5 L (12.0%)Rejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹49.2 L+₹11.3 L (29.7%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹49.7 L+₹11.7 L (31.0%)Rejected-Finance SUBHASH CHOWK BARMER RAJSTHAN 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹49.7 L
EMD Value
₹99,400
Closing Date
19 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Jaisalmer
GE Army Jaisalmer - 345001
CONSTRUCTION OF ATT TOILET AND BATHROOM BLOCK, SPL REPAIR OF HARD STANDING STONE SET AND MINOR WORK IN CERTAIN UNITS UNDER GE (A) JAISALMER
2023_MES_629233_1
8332/23-24/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹99,400
Yes
5 Apr 2024
21 Nov 2023
21 Dec 2023
21 Nov 2023
19 Dec 2023
5 Dec 2023
Amount
Excavation over areas n.exc 1.5m depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified & directed by Engineer-in-charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified & directed by Engineer-in-charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge.
Removing excavated material soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
Removing excavated material (Soft/disintegrated rock) exc. 250 m but n exc. 500 m and depositing where directed complete all as specified & directed by Engineer-in-charge.
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified & directed by Engineer-in-charge.
M&L for 40mm thick damp proof course mix with liquid water proofing compound @ 200ml of 50kg of cement, to horizontal or vertical surface including necessary formwok in cement concrete (1:2:4), type B-0 (using 12.5mm graded stone aggregate) and applying evenly a coat of blown type bitumen at the rate of 1.50kg per square meter and blinding with clean dry sand @0.05 Cum. per Sqm complete all as specified & directed by Engineer-in-charge. (Note:-Supply only Liquid water proofing compound shall be measured and paid seperately)
M&L for moorum/ red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified & directed by Engineer-in-Charge.
M&L for precast cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) as in block masonry with solid blocks exceeding 10cm width and setting in cement mortar 1:6 complete all as specified & directed by Engineer-in-Charge.
M&L Jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25 to 35cm wide, hoisted and set, jointed and grouted in cement mortar (1:3) complete all as specified & directed by Engineer-in-charge.
M&L for 50 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in Padding complete all as specified & directed by Engineer-in-charge.
HIGH BUILD ELASTOMERIC LIQUID MAMBRANE (PU BASED): M & L For applying of polyurethane based tar extended seamless elastomeric protective coating system, conforming to ASTM C-836-03 and ASTM C 898-09 ideally suited for waterproofing of roof, walls and foundation MAKE: CICO CORCHEM 206I or equivalent in FOSROC/STP/SIKA/ BASF, following the single component solvent based polyurethane compound CORCHEM 2P or equivalent in FOSROC /STP/ SIKA/BASF recommended to be used as a primer before application of CORCHEM.
M&L for sand stone slabs 100mm in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar (1:2) or cement mortar (1:4) complete all as specified & directed by Engineer-in-charge.
M&L for sand stone slabs 50mm in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar (1:2) or cement mortar (1:4) complete all as specified & directed by Engineer-in-charge.
M&L plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straigth or curved) complete all as specified & directed by Engineer-in-charge.
M&L for hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in-charge.
M&L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in sub base of flooring/ hard standing & finished the surface even & fair complete all as specified & directed by Engineer-in-charge.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base of flooring/ hard standing & finished the surface even & fair complete all as specified & directed by Engineer-in-charge.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed by the Engineer in Charge.
M&L for glazed ceramic coloured tiles 450x300x7mm thick (Jointless) in vertical surfaces etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 10mm thick backing coat in CM (1:4) complete all as specified and directed by the Engineer in charge.
M&L for rendering 15 mm thick, plaster in cement mortar (1:6) on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and smooth without using extra cement complete all as specified & directed by Engineer-in-Charge.
M&L for rendering 15mm thick on brickwork or concrete on wall surfaces in cement mortar (1:4), finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L for rendering 5 mm thick plaster in cement mortar (1:3) on concrete surfaces of ceiling and finishing the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for preparing new plastered or unplastered surfaces and applying three coats of white wash on ceiling all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of walls and apply two coats of distempering oil emulsion over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified & directed by Engineer-in-charge.
M&L for 50 mm thick PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) laid in alternative bays as in plinth protection including finished the surface even & fair without using extra cement & filling the joints with mastic filling i.e one part of bitumen 85/25, 3 parts of sand by weight complete all as specified and directed by Engineer-in-charge.
S&F solid PVC door frame of size 50x47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S. Square tube suppling and fixing in opening as per specification and drawing complete all as specified & directed by Engineer-in-charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with single piece extruded PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement of single piece extruded PVC profile for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F 150 mm size aluminium anodised barrel tower bolts of extruded section all as specified & directed by Engineer-in-charge.
S&F 150 mm size aluminium handle, cast type, anodiesed complete all as specified & directed by Engineer-in-charge.
S&F, 100mm size, butt hinges, medium weight, cold rolled mild steel including necessary welding if required all as specified & directed by Engineer-in-charge.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified & directed by Engineer-in-charge.
S&F 1000 litres capacity, three layered, white colour Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified & directed by Engineer-in-charge.
S&F vitreous china white wash down water closet pan, pedestal pattern including fixing bolts, plastic water closet seat and cover with recessed bottom with MS CP hinging device (excluding flushing cistern and flush pipe) complete all as specified & directed by Engineer-in-charge.
S&F Vitreous china squatting pan orissa pattern, size 580X440 mm white, with intregral foot rests (excluding flushing cistern and flush pipe) complete all as specified & directed by Engineer-in-charge.
S&F Vitreous China urinals, half stall type, white excluding flushing cistern, flush pipe and waste pipe bowl type (back or corner wall type) complete all as specified & directed by Engineer-in-charge.
S&F vitreous china wash basin white, flat back of size 550 x 400 mm white including waste fittings, brass, chromium plated, coupling, waste pipe, brackets including cutting for and pinning in ends of brackets errect stand, fixing waste pipe complete all as specified & directed by Engineer-in-charge.
S&F 15 mm bore Bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F 10 Litres, PVC, valve less, syphonic action type, Flushing Cistern, high level, white inlet, ball valve, float, and handle including brackets complete all as specified & directed by Engineer-in-charge.
S&F 4 mm thick figured Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane complete all as specified and directed by the Engineer in charge.
S&F 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed by the Engineer in charge.
S&F 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed by the Engineer in charge.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by the Engineer in charge.
S&F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified and directed by the Engineer in charge.
S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified and directed by the Engineer in charge.
S&F 75 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed by the Engineer in charge.
S&F 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed by the Engineer in charge.
S&F 75 mm bore PVC (SWR) Vent Cowl complete all as specified and directed by the Engineer in charge.
S&F 110 mm bore PVC (SWR) Vent Cowl complete all as specified and directed by the Engineer in charge.
S&F Steel ventilators with top hung shutter including hinges, steel peg stay, complete
S&F 15 mm bore stop cock, fancy type, chromium plated, with long shank and cup (concealed type) cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for union complete all as specified & directed by Engineer-in-charge.
S&F of Grating doom 100mm dia of PTMT (Minimum weight 25Gms) complete all as specified and directed by the Engineer in charge.
S&F 20 mm bore Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by the Engineer in charge.
S&F in repair PVC ball valve 20 mm dia high pressure with polythene float and fly nut complete screwed for iron pipe or brass fernule and fixed complete all as specified and directed by the Engineer in charge.
S&F 450 mm long PVC connection pipe of 15mm bore with PTMT nut at both ends complete all as specified and directed by the Engineer in charge.
S&F 32 mm High density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed by the Engineer in charge.
S&F tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and directed by the Engineer in charge.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed by the Engineer in charge.
S&F cast iron floor trap 100mm size with grating including joining to waste fixed in cement concrete type B1 (1:2:4) complete all as specified and directed by the Engineer in charge.
S&F cast iron Traps 'P' or 'S' 75mm dia complete all as specified and directed by the Engineer in charge.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in disintegrated rock complete all as specified and directed by the Engineer in charge.
M&L for cement concrete in foundation filling and mass-concrete Type B2 (1:2:4), using 40mm graded stone aggregate complete all as specified and directed by the Engineer in charge.
S&F framed work, trusses, trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats 'J' hook Clips etc Fe 410W (Gde-E 250 quality B) complete all as specified and directed by the Engineer in charge.
M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and directed by the Engineer in charge.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 150mm bore pipe all as specified & directed by Engineer-in-charge.
M&L for 150mm bore salt glazed stoneware drain pipes (ISI marked) laid in trenches and jointed in CM (1:1) and tested complete all as specified & directed by Engineer-in-charge.
M&L for rendering 15 mm thick on brickwork or concrete on wall surfaces in cement mortar 1:4, finished even and fair without using extra cement including mixing of water proofing compound complete all as specified & directed by Engineer-in-charge. Note :- Supply only WPC will be measured and paid separetly.
Supply only integral water proofing compound all as specified & directed by Engineer-in-charge.
M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete for 50 users complete all as specified & directed by Engineer-in-Charge.
M&L for Soakage well excavation in any type of soil foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M25concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC Cover Slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2m dia x 3M effective depth complete all as specified & directed by Engineer-in-charge.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushioning complete all as specified & directed by Engineer-in-charge. Note :- (i) Pattern of interlocking tile to be rubber moulded or equivalent as approved by GE. (ii) Rate quoted by the contractor shall deemed inclusive of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) packing and finished even and fair to the sides of pavement.
Dismantling of stone sett paving pointed in any mortar of any description or thickness complete all as specified & directed by Engineer-in-charge.
M&L for Stone sett flooring with granite trap stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, 20mm thick; joints grouted in cement mortar 1:2 with an admixture of metallic floor hardner, 5% by weight of cement and struck flush complete all as specified & directed by Engineer-in-charge. Note : Stone for the setts shall be of the best quallity , granite trap basalt or quartzite . use of sedimenetary stone shall not be permitted. Stone setts shall be approximately rectangular in shape with a tolerance of plus or minus 12mm.
All as per item No. 78.00 above but except stone setts complete all as specified & directed by Engineer-in-charge.
Demolition of cement concrete unreinforced in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer-in-charge.
M&L, plain cement concrete (1:1.5:3) M-20 grade type A-1 (20mm graded stone aggregate) as in sub base of flooring/ hard standing complete all as specified & directed by Engineer-in-charge.
M&L for Point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.6 mm with 3 mm thick phenolic laminated white sheet cover for mounting of Piano Type switches, sockets, fan regulators complete for the following :-
(a) One light/ceiling fan point controlled by one switch.
(b) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(c) One socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No 82.00 here-in-before but of size cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) for one 16 amp socket outlet controlled by one switch on independent board complete.
S&F switch piano flush button single pole one way 5/6 amp complete all as specified & directed by Engineer-in-charge.
S&F switch piano flush button single pole one way 16 amp complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 3 pin ,6 & 16 amp flush type complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete all as specified & directed by Engineer-in-charge.
S&F ceiling rose 6 amp, 3 plates polycarbonate body complete all as specified & directed by Engineer-in-charge.
S & F surface and wall mounted LED tube light along with fixture, 4 ft, 20 W, extruded aluminium housing provided for efficient heat disspation with polycarbonate ,operating voltage 240 V, 50HZ, AC supply and operating tempureture 0 to 50 C, power factor >0.9, lumen output > 2000 and provision of new 3 core multistanded copper conductor of size 23/0.193 from ceiling rose to fitting with white colour flexible pipe complete all as specified & directed by Engineer-in-charge.
S & F of LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten,extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver,optic diffused type ENDURA LINER NEO including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified & directed by Engineer-in-charge.
Supply and fixing of building security light fitting LED 35 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as lihjting souce and PC cover having TOP opening sepreate drive compartment etc and connecting complete all as specified & directed by Engineer-in-charge.
S&F bracket of GI pipe medium grade of 40mm dia, 1.2 meter in length clamps made of FI 40 mm x 6mm incl nuts, bolts & washers, painting complete all as specified & directed by Engineer-in-charge.
Supply & fix steel body heavy duty exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified & directed by Engineer-in-charge.
Cutting of wall with mason for making window suitable for fixing of 300 mm exhaust fan and making good as per existing surface of wall complete all as specified & directed by Engineer-in-charge.
S&F for MCB DB SPN 12 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole and neutral 32 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole 10 Amps to 32 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
M&L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground levl connected to galvanized iron wire 4 mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and GI cover and testing on completion complete all as specified & directed by Engineer-in-charge.
NOTE FOR ITEM No. 98.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to DBs or any other indicated situation for loop earthing with GI wire 4 mm mm size complete all as specified & directed by Engineer-in-charge.
S&F for GI Tubing light grade 20 mm dia.for cable protection complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 15mm bore dia medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls, ceilings etc complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 20mm bore dia medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls, ceilings etc complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 25mm bore dia medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls, ceilings etc complete all as specified & directed by Engineer-in-charge.
S&F gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the size 20 mm bore with fittings and accessories. ISI marked and as per IS 14846 complete all as specified & directed by Engineer-in-Charge
S&F gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the size 25 mm bore with fittings and accessories. ISI marked and as per IS 14846 complete all as specified & directed by Engineer-in-Charge
M&L for cutting the existing pipe and inserting Tee 50x50x25mm complete all as specified and directed Engg-in-Charge.
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. (Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment).
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
Supply and laying steel water tubing 20 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc complete all as specified & directed by Engineer-in-charge.
Supply and laying LT XLPE insulated, armoured heavy duty, electric cable, with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 Core complete all as specified & directed by Engineer-in-charge.
Supplying. installing. commissioning and testing of hi wall split type air conditioner units of capacity 1.5 TR, indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality 5 star rating non CFC type with nominal cooling capacity system complete all as specified & directed by Engineer-in-charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified & directed by Engineer-in-charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 volts complete all as specified & directed by Engineer-in-charge.
S&F for circuit/submain wiring alongwith earth wire with 2x6.0 Sq. mm + 1x6.0 Sq. mm earth wire of FRLS PVC insulated copper conductor, single core with and including PVC conduit medium grade of size 25mm recessed including make good the distrubed surface as per existing surface complete all as specified & directed by Engineer-in-charge.
S&F for sheet metal enclosure MCB SPN DB 4 way with 200 Amps rated bus bar 240 volts double door IP 43 with magnitic locking system complete all as specified & directed by Engineer-in-charge.
S&F MCB single pole & neutral 63 Amps, 240 Volts, AC supply, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge.
S&F MCB single pole 40 Amps, 240 Volts, AC supply, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge.
M/s Ramniwas Bishnoi
M/s Shri Inder Construction Company
AMBEY MAA CONSTRUCTION COMPANY
Paliwal Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .