Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹32.6 L+₹14.9 L (83.5%)Rejected-AOC 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L2 | Rejected-AOC Second lowest bidder | |
| 3 | Not Admitted-Fee/PreQual/Technical 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹18.5 L
Closing Date
28 Apr 2021, 6:00 pmClosed
Director, CSIR-NML
CSIR-NML, Jamshedpur
Annual Contract for Comprehensive Maintenance and Operation of Package A. C. Plants and Comprehensive Maintenance for Cooling Appliances in Main Lab., LSTF, Pilot Plant and Housing Areas of CSIR-NML for the year 2021-22-23
2021_CSIR_75836_1
NML/ENG./WSM/eNIT/04 (01)/2021-2022
Open Tender
Miscellaneous Works
Item Rate
365 days
CSIR-NML, Jamshedpur
As per eNIT
8 documents required · 8 mandatory
₹0
Exempted
14 Jul 2021
16 Apr 2021
30 Apr 2021
17 Apr 2021
28 Apr 2021
17 Apr 2021
Amount
PART A
Comprehensive Maintainance & Operation of Calibration Centre package A.C plants (2 X 15TR); as required; Make: VOLTAS, Model No: 50BA016N with: (a) Semi Hermetic Compressor - 15TR X 02 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No.
Comprehensive Maintainance & Operation of Library package A.C plants (4 X 15TR); as required; Make: VOLTAS, Model No: DPUW-SH150S with: (a) Semi Hermetic Compressor - 7.5TR X 08 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No.
Comprehensive Maintainance & Operation of Conference hall package A.C plants (2 X 10TR); as required; Make: BLUE STAR, Model No: PAW1028 with: (a) Semi Hermetically Sealed Compressor - 5TR X 04 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No.
Comprehensive Maintainance & Operation of Analytical Chemistry Lab. package A.C plants (2 X 10TR); as required; Make: BLUE STAR, Model No: PAW1028 with: (a) Semi Hermetically Sealed Compressor - 5TR X 04 Nos. (b) Condensor water circulation centrifugal monoblock pumps - 2Nos. (c) Cooling Tower (with fan motor) - 01 No.
PART B
Comprehensive AMC for window type room AC of capacity upto & including 2TR; as required (Total Qty in 4Qtrs.=170Nos.x4=680)
Comprehensive AMC for Split type room AC (Hi-wall mounted/Cassette AC/Floor Mounted AC), Ductable AC of below mentioned capacity; as required:
Upto & including 2TR (Hi-wall type, Cassette type, Floor mounted) (Total Qty in 4Qtrs.=322Nos.x4=1288)
3TR (Cassette type AC; make Voltas) (Total Qty in 4Qtr.=2Nos.x4=8)
5.5TR (Ductable type AC; make: Carrier) (Total Qty in 4Qtrs.=2Nos.x4=8)
7.5TR (Ductable type AC 3 x 2.5 TR reciprocating compressor; make Carrier) (Total Qty in 4Qtrs.=2Nos.x 4=8)
Comprehensive AMC for water chilling unit of below mentioned capacity; as required:
upto 1.5TR (Total Qty in 4Qtrs.=3Nos.x4=12)
4TR (Total Qty in 4Qtrs.=1Nos.x 4=4)
Comprehensive AMC for water cooler of below mentioned capacity; as required:
upto 80 litres (Total Qty in 4Qtrs.=13Nos.x4=52)
150 litres (Total Qty in 4Qtrs.=1No.x4=4)
PART C (Miscellaneous Work)
Installation, Testing & Commissioning of following; as required (Including supply of the following:- Teak wood beat (Well varnished/ polished teak beat (3" or 4" wide, thickness 0.5") on the sal wooden frame around the window AC, if required) & Plastering, POP work/ painting, Copper pipe (suction & discharge line) duly insulated with nitrile foam, uPVC (Sch.40) water line pipe, Braided pipe, drain line, FR electrical cable, 15A plug top, leak testing, refrigerant charging (if desired)); as complete (see scope of work)
Window type room AC including making pocket or in existing pockets for window type AC; as required
Split type AC (Hi-wall mounted/ cassette AC) with supply of ready made stand for condensing unit ; as required
Supply & fixing of 50mm of medium class PVC conduit along with accessories (including T joint etc) in surface/recess including cutting the wall and making good the same in case of recessed conduit; as required
CARRION AIR COOLING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .