Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | ₹18.8 L Quoted ₹19.2 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹19.7 L+₹52,541.50 (2.74%)Rejected-Finance | ₹19.7 L+₹52,541.50 (2.74%) | L2 | Rejected-Finance HIGHER BIDDER |
| 3 | L3₹20.9 L+₹1.8 L (9.16%)Rejected-Finance | ₹20.9 L+₹1.8 L (9.16%) | L3 | Rejected-Finance HIGHER BIDDER |
| 4 | L4₹21.2 L+₹2.0 L (10.5%)Rejected-Finance | ₹21.2 L+₹2.0 L (10.5%) | L4 | Rejected-Finance HIGHER BIDDER |
| 5 | L5₹23.8 L+₹4.7 L (24.5%)Rejected-Finance SALGAONKAR HOUSE DRIVERS HILL VASCO DA GAMA GOA 403802 | SOUTH GOA | GOA | 403802 | ₹23.8 L+₹4.7 L (24.5%) | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
28 Sept 2021, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS OF P 46 AT NCB GOA UNDER GE GOMANTAK VASCO
2021_MES_467883_1
85466/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE GOMANTAK VASCO
₹42,000
Yes
3 Nov 2021
13 Aug 2021
1 Oct 2021
13 Aug 2021
28 Sept 2021
14 Sept 2021
Amount
Schedule 'A' -Part I (B/R Works)
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F Rolled mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) GDE Fe 410-0 W (Gde E-250) quality A complete all as specified and as directed.
M & L for two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome primer complete all as specified and as directed.
Dismantling asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings including ridges complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry Type C-5, 20mm graded aggregate with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete all as specified and as directed.
Taking down cement plaster on brick work or stone walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for rendering in cement mortar 1 : 6 ,15mm thickness on brick/cement/stone surfaces and finishes the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for providing two coats of oil-bound distemper over a coat of alkali-resistant primer on new plastered surfaces wall care putty 1 mm thick including necessary preparation to surfaces complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed.
M & L for rendering 5mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceiling complete all as specified and as directed.
M&L for providing three coats of white wash on new plastered ceiling surfaces including necessary preparation to surfaces complete all as specified and as directed.
M & L for preparation of old decorated surfaces of walls including cornices, pillars etc and applying one coat of oil bound distemper complete all as specified and as directed.
M&L for preparation of old decorated plastered surfaces of walls including cornices and applying one coat of white wash on wall fascia cornices etc complete all as specified and as directed. (Incl removal of all vegetation).
M&L for preparation of old decorated plastered surfaces and applying one coat of white wash on ceiling surface complete all as specified and as directed.
M&L for 10 mm thick rendering with cement mortar 1:3 on brick/concrete surfaces of walls finished even and smooth complete all as specified and as directed.
M&L for rendering in cement mortar 1 : 4 (10+5)=15mm thickness on brick/cement/stone surfaces and finishes the surface even and smooth without using extra cement including mixing with liquid WPC on top 5mm thick only complete all as specified and as directed. Note :- Water proofing compound will be paid separately
M&L for two coats of acrylic emulsion exterior paint of approved make over a coat of acrylic emulsion primer on new surface including preparation of surface of any description complete all as specified and as directed.
M&L for complete removal of existing treatment and providing two coats of acrylic emulsion exterior paint of approved make over a coat of acrylic emulsion primer on old treated surface of any description including preparation of surface complete all as specified and as directed.
M&L for preparation of old painted steel surfaces over 10 cm width/girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood over 10 cm width/girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for providing & making Centering, shuttering, Formworks for columns, beams & slabs including strutting, propping etc. and removal of form for (a) columns, pillars, Piers, Abutments, Posts and Struts. Complete as directed by the engineer in charge. Notes: Same scaffolding to be used for Ext painting works as specified and directed.
Chipping off existing loose, damaged concrete from RCC members of all affected RCC Columns, beams, slabs and chajjas on external and internal faces etc. beyond main reinforcement .(if required in the opinion of the consultant), carefully with chisel and hammer including relieving structural members such as column, beam and slabs of their superimposed load partially or fully by provision of adjustable steel props, frames etc. Providing and applying rust passivator of approved make to existing reinforcement bars including wire brushing of reinforcement, cleaning, washing of concrete etc complete as directed. Providing and applying two coats of rust preventer slurry of approved make and cement in proportion 1:1.5 to existing r/f bars as directed complete. Providing and applying bonding coat of slurry of approved make and cement in proportion 1:1 to concrete and reinforcement sub strata complete as directed. Providing and applying bonding coat of approved make. Polymer modified cement mortar in required proportion (1:5:15) to RCC members including hand packing, curing and making the surface rough for plastering complete all as specified and as directed.
Supply only Liquid water proofing compound of approved make, 200ml per bag of cement) complete all as specified and as directed.
M&L for replacement of steel reinforcement with TMT (CRS) bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter of approved make and applying protective coating of approved make complete all as specified and as directed.
FILLING AND REINSTATING OF SEPARATION CRACKS Opening the Separation Cracks at the Junctionof RCC and Masonry where ever directed and instructed into *’V” Grooves 2” to 3 ” from the either side of the cracks by carefully marking the areas to be opened up using a Cutting machine and skillfully /carefully Chiseling with a well sharpened chisel and hammer as directed including Wire brushing and washing of concrete Substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the Consultant as instructed and directed.
Structural grade bonding in moistures surface areas, Providing and applying two component non-remulsifiable epoxy resin bond coat (EL Monobond) on old concrete face confirming to ASTM-C- 1059-86 Type II prior to application of any type of mortar or section build-up using cementious media to ensure bond between old concrete & new concrete by brush application. Complete as directed by consultant.
Teflon nozzles compatible with epoxy injector Drilling Holes of 12mm dia, upto 100mm deep holes in structural members at the intervals of 500mm c/c for slab, 300 mm c/c for column and beam in staggered manner or along the crack as directed by the consultants in RCC structural element including cleaning of the holes by air blower and Inserting 12mm dia. Teflon nozzles compatible with epoxy injector and having machined external end to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing and allow to cure the system for min.8 hrs before grouting including removing nozzle projections, excess putty if any over concrete element grinding, levelling and finishing the external surface, after completion of the work, etc complete as directed by the engineer in charge
Epoxy, Injection, Grouting Injecting/Gravity pouring / deck flooding over porous slab or concrete area with low viscosity high molecular weight thermoset polymer grout Monopol 250 H or equivalent to improve the micro structure of concrete, including mixing material components part a and part b in required quantities as per mfg instruction by weigh batching spreading on area by broom brush at a rate of 1kg/sqm. Monitor leakages through other side of the member and seal them as per the requirement. Broadcast quartz sand over tacky surfaces to ensure mechanical keys for subsequent coating. Allowing the system to cure etc. complete. Test the system for pull out at 3 locations. Complete as directed by engineer in charge.
Repairing damaged concrete areas using non shrink, free flow and corrosion inhibiting micro concrete (not exceeding to depth 50 mm ). Rebuilding the section of damaged RCC elements to its original size or as per consultants recommendations by providing and casting with micro concrete of grade M40 all lead lift, mixing, placing, levelling the surface by grinding off cementitious slurry or construction joint differences if any to satisfaction of Engineer in charge, curing etc. complete. Ensure the quality of water by testing water as per IS 456 and document the same. Ensure temperature at time of mixing should be between 25 to 40 degree Celsius by electronic temperature gauge Complete as directed by the engineer in charge.
Providing, Supplying, transporting materials, drilling holes by rotary hammer drill, dust removing, batching, mixing of resin and hardener Hilti HY 200, inserting & anchoring rebars of 8 mm dia rebar in 12 mm dia holes and 110 mm deep using HY 200dia. in existing concrete surfaces using resin based anchoring grout and necessary rebaring of reinforcement steel (steel rebars to be paid separately) complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for rendering 10 mm thick as backing coat in cement mortar 1:4 to receive skirting tiles/stone slab complete all as specified and as directed.
M&L for 20mm thick screed bed or bedding layer of mortar for laying tiles in cement mortar 1:6 complete all as specified and as directed.
M&L for glazed coloured ceramic tiles in vertical surface 350x250x7mm/ 450x350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with colour tiles complete all as specified and as directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick area of each tiles exc 0.18 sqm but n exc 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white cement or coloured cement to match complete all as specified and as directed.
M&L for vitrified ceramic tiles light shed 10 mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 sqm but in floors etc set & jointed in neat cement slurry & pointed in white or coloured cement with pigment to match including 15 mm thick screed bed (1:4) in cement mortar complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20-25mm thick cement screed base over & including 10mm thick rendering (bedding layer) in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for machine cut kota stone slab of 18 to 20mm thick, in riser of steps, skirting, dado etc. over & including 10mm thick rendering (bedding layer) in cement mortar 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror finished complete all as specified and as directed.
M&L for green marble work 15 to18 mm thick (table rubbed and polished) in steps, jambs, pillars, windowsills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and as directed.
Taking up or down 15 mm steel tubing and connections, fixed to wall /floor complete all as specified and as directed.
Taking up or down 20mm steel tubing and connections, fixed to wall /floor complete all as specified and as directed.
Taking up or down 25 mm steel tubing and connections, fixed to wall /floor complete all as specified and as directed.
Supplying and laying of 15 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of 25 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) n.exc 1.50 sqm each complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) .exc 1.50 sqm but n exc 4 sqm each complete all as specified and as directed.
S&F Powder coated aluminium window/ventilators shutter including frame, any type sliding or openable with frame, & other similar work etc. fabricated by using the approved standard section including necessary arrangements to receive 4mm thick glass or wire mesh with aluminium channel beading & stainless steel screws including the cost of rubber gasket/rubber beading etc. complete including necessary handles, roller wheels, hinges etc complete all as specified and as directed. Note :- Weight of aluminium section shall be measured exclusive of all fittings fixtures, hinges, handle, bolts, rubber gasket/rubber beading and locking arrangements.
S&F of powder coated anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m ncluding necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed.
S&F Aluminum powder coated deco grill make DG 104 (10 mm thick section) with frame of section not less than 0.136 kg/rm complete all as specified and as directed.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 05 sqm in each pane complete all as specified and as directed.
S&F aluminium alloy anodised wire mesh of size 1.5 mm x 3 mm mesh 20 Gauge thick of approved make complete all as specified and as directed.
M&L for filling the gap between window& wall with silicon sealant over cement mortar 1:1 and complete all as specified and as directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube complete all as specified and as directed.
S&F Solid PVC moulded door shutter with particle board core, 28 to 30mm thick ( stiles) with 2 raised panels designed with 2mm thick moulded PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face complete all as specified and as directed.
S&F 2nd class hard wood plain solid straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S&F 30 mm thick 2nd class hard plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed.
M&L for preparation for new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
S&F Butt hinges, 100mm long, medium weight, stainless steel complete all as specified and as directed.
S&F Aluminium handles, cast type, anodised 150 mm long complete all as specified and as directed.
S&F Aluminium, anodised barrel tower bolts 150mm long of extruded section and fixed complete all as specified and as directed.
S&F Aluminium alloy anodised sliding door bolt 300mm long with hasp, staple and fixing clips of sheet, cast or extruded sections and fixing bolts complete all as specified and as directed.
Dismantling water tanks and removing to store of capacity exc 500 and not exc 1000 ltr complete all as specified and as directed.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, for 500 ltrs capacity complete all as specified and as directed.
S&F 20 mm dia ball brass valve, high pressure with polythene float and fly-nut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed.
S&F in repairs vitreous china wash down water closet pan semi-pedestal pattern (Anglo-Indian Type) white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and as directed.
S&F PVC valveless, symphonic action type, flushing cistern, 10 liters, low level, white, with inlet, ball valve, float and handle including brackets and connections to pipes and fixing of chain and pull, or level, if any fixed in repairs including flush pipe complete all as specified and as directed.
S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed.
S&F Stainless steel soap dish standard size heavy complete all as specified and as directed.
M&L for 100 mm dia Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
S&F in repairs flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern complete all as specified and as directed.
S&F in repairs vitreous china wash basin, white, ovel shaped back, size 630x450mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and as directed.
S&F Pillar taps, 15mm dia, cast copper alloy, fancy type with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed in repairs complete all as specified and as directed.
S&F Concealed CP stop cock/angle cock 15mm dia, fancy type with capstone heads screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and as directed.
S&F Bib taps, 15mm dia, cast copper alloy, fancy type, with capstone head, screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs complete all as specified and as directed.
S&F Swivel shower of C P Brass any colour for fixing with 15mm pipe .(Minimum weight 40gms) fixed in repair complete all as specified and as directed.
S&F Shower arm 15mm size,195mm long with bend of 45degree with flange of CP brass any colour. (Minimum weight 40gms) fixed in repair complete all as specified and as directed.
S&F Towel Rail 600mm long of CP brass fixed with and including Chromium plated brass screws and wooden/plastic cleats .(Minimum weight 190gms) fixed in repair complete all as specified and as directed.
S&F PVC connections 15 mm size with PTMT nuts of length 600m fixed in repair complete all as specified and as directed.
M&L for cleaning of roof tops including removing the existing treatment by brooming down with steel wire brushing scrapping down with steel scrapper and roughening the existing surfaces to receive plaster complete all as specified and as directed by Engineer-in-Charge. Note: The debris out the cleaning/removing/ scraping shall be removed out MD Land complete all as specified and as directed.
M&L for providing 10mm thick cement plaster over roof slab (over the area of dismantled roof treatment ) in cement mortar 1:3 finished even and smooth without using extra cement with WPC complete all as specified and as directed. Note:WPC shall be measured and paid separately)
Supply & Laying water proofing treatment using 4mm thick APP modified membrane and as per manufacturers instructions with features as specified , weighing not less than 4.0 kg per Sqm laid over a coat of cold applied bituminous primer @ 0.20 Kg per sqm by torching the membrane including sealing the overlap while torching with 100mm on length side and 100mm wide side as per manufacturer instructions including joints and changes in direction the curved with cement mortar 1:3 mixed with SBR latex @ 200 Ml/bag of cement cured well before laying of membrane all as per manufacturer instructions and to the satisfaction of Engineer -in-charge including two coats of bituminous aluminium paint all as specified and directed. Note (i) irrespective of lap the net covered area will only be measured for payment. (ii) The quoted rate is deemed to be inclusive of primer APP membrane & SBR Latex.
Demolition of cement concrete (reinforced) of any description and any position complete all as specified and as directed.
M&L for RCC type B-1, 1:2:4 (using 20 mm graded aggregate) as in landings, cover slabs (for drains, man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and as directed.
M&L for CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Taking down steel doors exc 1.5 sqm not exc 4 sqm each (without taking off shutters from the frame) complete all as specified and as directed.
S&F Steel rolling shutters (Thickness of laths in 1.25) mm, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type but gear operated type with chain wheel and hand chain complete all as specified and as directed.
M&L for preparation of new untreated steel surfaces of any description and applying two coats of aluminium paint over a coat of primer complete all as specified and as directed.
Demolition cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for 75 mm thick plain cement concrete type C2 1:3:6 (40 mm graded aggregate) as in plinth protection, without using extra cement for finishing complete all as specified and as directed.
M&L for plain cement concrete 1:3:6,Type C2 (using 40 mm graded stone aggregate), 100mm thick as in sub base all and finished to an even and fair surface as without using extra cement complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor finish cement mortar 1:4 complete all as specified and as directed.
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick,set, jointed and pointed in neat cement slurry in floors with Grey cement and pigment complete all as specified and as directed.
Removing building materials etc. to a distance of 2.00 km, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed.
Dismantling of cast iron drain pipe 100mm dia jointed in cement mortar and taking out of trenches/wall/floor etc incl fitting in foul condition complete all as specified and as directed.
S&F PVC (SWR) pipes 110 mm single socketed in any length with rubber ring joints fixed to walls in foul condition complete all as specified and as directed.
S&F PVC (SWR) pipes 75 mm single socketed in any length with rubber ring joints fixed to walls in foul condition incl complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
M & L for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; handmade sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed.
Schedule 'A' -Part II (Internal Electrification)
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed
M&L for point wiring complete with 1100 volts grade PVC insulated and unsheathed multi stranded 1.5 Sq mm FRLS single core copper conductor cable drawn through and including PVC casing and casing (surface) ISI marked with all accessories, & sunken pressed steel terminal boxes made out of 2 mm thick MS sheet concealed in walls with 3 mm thick laminated Hylem sheet top cover fixed with brass screws for housing switches, socket, regulator etc including 1.5 Sq mm PVC insulated and unsheathed multi stranded copper conductor cable as earth continuity wire all as specified for one light, fan, socket outlet etc and making good disturbed surface of walls and floors to match with existing surfaces complete all as specified and as directed
All as per item No 106 here in above but for One light point controlled by two Nos two way switches complete all as specified and as directed
All as per item No 106 here-in-before but one 5 pin switch socket outlet 5 Amps on independent board controlled by one switch complete all as specified and as directed
All as per item No 106 here-in-before but one 6 pin socket outlet 15 Amps independent/metal plug and socket with cables 4 sq mm size copper PVC insulated cable multi stranded and 4 sq mm cable conductor complete all as specified and as directed
S& F Switch piano flush button single pole one way 05 Amps complete all as specified and as directed
S&F Switch piano flush type single pole, two way 5 Amp complete all as specified and as directed
S & F Switch socket combination 2 in 1, 3/5 pin 5 Amp flush type universal complete all as specified and as directed
S&F Switch socket combination 2 in 1, 3/5 pin 15 Amp flush type universal complete all as specified and as directed
S&F Stepped type electronic fan regulator electronic flush type 300 watt on existing phenolic laminated sheet etc including removal of old complete all as specified and as directed
Taking down carefully existing ceiling fan of any sweep & make, complete with down rod and opening greasing, oiling including replacement of nut bolt, washer, rubber bush, pin replacement of PVC flexible wire not less than 1 m from the ceiling rose to fan complete & refixing complete all as specified and as directed
S&F 25W 4ft long LED batten light fitting with 2.5 KV voltage surge protection ,PF >0.9 complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size .(note : if 25 W LED T/L fitting not available than next higher wattage will be provided by the contractor without any extra cost) complete all as specified and as directed
S&F 10 Watts LED Batten fitting 2ft long ,integrated type ,plastic body with white acrylic cover complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including removal of old unserviceable one complete all as specified and as directed
S&F in repairs exhaust fan 300 mm sweep plastic body, 230 volts including making hole in wall suitable as per new ext fan size complete all as specified and as directed
M&L for sub main wiring with single core 1100 V grade conforming to relevant IS, PVC insulated unsheathed cables two run of 4 Sq mm multi stranded copper conductor drawn through and including suitable size non metallic PVC caping casing incl all accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 4 sqmm copper wire earth continuity conductor connecting to existing main switch board \ Distribution Board and testing on completion etc including taking down old submain wiring of any type with conduit/capping casing and making good disturbed surfaces to match existing complete all as specified and as directed. Note : Three runs of 4 sqmm cable and one run of PVC Capping casing not less shall be measured as one run.
M&L for sub main wiring (single phase) with single core 1100 V grade conforming to relevant IS, PVC insulated unsheathed cables two runs of 6 Sq mm multi stranded copper conductor drawn through and including suitable size non metallic PVC caping casing incl all accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 6 sqmm copper wire earth continuity conductor connecting to existing main switch board \ Distribution Board and testing on completion etc including taking down old submain wiring of any type with conduit/cpaing casing and making good disturbed surfaces to match existing all as specified and directed. Note : Three runs of 6 sqmm cable and one run of PVC Caping casing suitable size shall be measured as one run.
S&F Sheet metal enclosure (DB) for MCBs, 4 way, triple pole and neutral, 415 Volts, double door with 200 Amps rated bus bars with IP 43- IK 09 complete complete all as specified and as directed
S&F Sheet metal enclosure (DB) for MCB's, 8 way, single pole and neutral, 240 volts, double door with 100 Amp rated Copper bus bar with IP 43- IK 09 complete all as specified and as directed
S&F MCB, Triple pole and neutral , 63 Amp, 415 Volts, 'C' series 10 KA complete all as specified and as directed
S&F MCB, single pole & Neutral, 6-32 Amp, 240 Volts, 'C' Curve 10KA complete all as specified and as directed
S&F MCB, single pole, 6-32 Amp, 240 Volts, 'C' Curve 10KA complete all as specified and as directed
M&L for earthing complete with GI steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including necessary earth work and excavation of in any type of strata, PCC 1:3:6 type C-2 GI tubing 20 mm dia for watering and 15mm dia GI tubing for protection of wire etc all as per electrical plate No.3 of SSR part I including connecting to electrical equipments and testing on completion. Note:Gi wire 4 mm up to 7.5 m length is deemed to be included under quoted rate.
S&F GI tubing (light grade) with all fittings, laid in trenches/floors or fixed along with walls /poles bore of pipe 50mm complete all as specified and as directed
S & F Ceiling rose, 3 phase/ PVC / polycarbonate, isolated body complete all as specified and as directed.
S & F LED Bldg Security Street light 30W ,IP 65 with 10KV surge protection including suitable size of GI pipe 1.2 m long bent to required shape, clamps, nut ,bolts and making electrical connection to the fitting with Suitable size of service wire complete all as specified and as directed
S&F Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with and including one single pole MCB 20 Amps, C series 240 Volts complete all as specified and as directed
Schedule 'A' -Part III (Lightning Protection)
M&L for earthing complete with copper plate earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top connected to Copper earth strip 20 x 3mm by means of bolts, nuts, check nuts and washers of brass and earth lead connected to main DB panel /meter box panel with including necessary and earth work and excavation including PCC chamber 1:3:6 and CI cover all as specified and or shown in electric plate No 3 of SSR-I. and testing on completion complete all as specified and as directed. Note: Copper earth strip 20 x 3 mm upto 7.5 RM is included in the unit rate quoted
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm copper strip complete all as specified and as directed.
M&L for test point terminal block made out of gun metal 75 mm x 75 mm x 25 mm drilled and screwed including three Nos 8mm dia 25 mm long hexagonal head screws and including provision of suitable MS box made out of 3 mm thick MS sheet to accommodate the terminal block all as specified and directed by Engr-in-Charge.
M&L for laying GI pipe 40mm dia light grade use for the protection of copper strip including taking down of old u/s pipes complete all as specified and as directed.
S&F Copper strip 20 x 3.15mm fix on porcelain insulator with necessary fastening items for roof conductors and down conductors above ground level as lighting conductor (including insulator) for building /store shed all as directed including removing the old Uunserviceable strips complete all as specified and as directed.
S&F Air termination, single pointed copper rod 12mm dia and 300 mm long including taking down of old termination strip complete all as specified and as directed.
M&L for preparation of old PCC 1:3:6 type C-1 using 20mm grade broken stone aggregate in coping including necessary form work complete all as specified and as directed.
M/S. M M S ENTERPRISES
M/s RAJ CONSTRUCTION
K M SUBHANAIAH
Tara Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .