Extension of Existing Pit No. 04 with associated infrastructural facilities for maintenance of 24 LHB coaches in rake at Chitpur.
ELEG-GSU-OT-22-2026-27
ELEG-GSU-OT-22-2026-27
Open
12 Months
Tapi, Gujarat
₹0
₹3.7 L
2 Jul 2026
2 Jul 2026
13 Jul 2026
I-(Non Schedule - Cabling and Wiring Works)
Supply of ISI marked XLPE insulated PVC outer sheathed, FR-LSH, armoured with aluminium conductor cable 1100V grade of size 4 core 35sq.mm as per IS no.7098 (part-1) 1988 or with latest amendment as per General Specification. (Cable Make:Havells/Gloster/Polycab/RR Kabel/ KEI/ Mescab)
Supply of ISI marked XLPE insulated PVC outer sheathed, FR-LSH, armoured with aluminium conductor cable1100V grade of size 4 core 70sq.mm as per IS no.7098 (part-1) 1988 or with latest amendment as per General Specification. (Cable Make:Havells/Gloster/Polycab/RR Kabel/ KEI/ Mescab)
Supply of ISI marked XLPE insulated armoured PVC outer sheathed, FR-LSH, Aluminium conductor cable1100V grade of size 4 core 240 sq.mm as per IS no.7098 (part-1) 1988 or with latest amendment as per General Specification. (Cable Make:Havells/Gloster/Polycab/RR Kabel/ KEI/ Mescab)
Supply of ISI marked XLPE insulated PVC outer sheathed, FR-LSH, armoured with aluminium conductor cable1100V grade of size 4 core 300 sq.mm as per IS no.7098 (part-1) 1988 or with latest amendment as per General Specification. (Cable Make:Havells/Gloster/Polycab/RR Kabel/ KEI/ Mescab)
Supply of HT XLPE insulated aluminium cable armoured of size 3 x 120mm2, 11KV. (Cable Make:Havells/Gloster/Polycab/RR Kabel/ KEI/ Mescab)
Trenching and laying of cable underground by soil cutting through suitable dia HDPE pipe, without sand and 6 bricks including refilling of trench by excavated soil and make good of surface as its original condition, (The cable trench should be of minimum 1000 mm depth). (HDPE Pipe Make: Skipper/ Capital Polyplast/Chaika Polymers/ Utkarsh/ Ashirvad/Arpan/Ori Plast)
Cable trenching, laying, refilling with bricks & sand, rising, jointing, socketing where necessary as per General Specification. (The cable trench should be of minimum 1000 mm depth)
Cable laying through 3" dia. GI Pipe along with supply of GI Pipe as per General Specification. (G.I. Pipe Make: TATA/ Jindal / Bansal )
Cable laying through 4" dia. GI Pipe along with supply of GI Pipe as per General Specification. (G.I. Pipe Make: TATA/ Jindal / Bansal )
Drawing of L.T. cable through PF wall / Structure by cleating / clamping etc as per General Specification.
Cable laying through pucca duct and refilling with sand and covering the duct as per General Specification.
Cable laying upon existing/supplied cable tray with necessary binding/clamps etc.
Construction of driving and reception pits to laying of 160mm dia HDPE pipes (PE80,PN6,IS:4984-1995)(with 13 supply of HDPE pipe) by Micro- tunneling method under the road, footpath, rail track etc. As per required depth to laying and inserting LT XLPE cable through HDPE pipes. (HDPE Pipe Make: Skipper/ Capital Polyplast/Chaika Polymers/ Utkarsh/ Ashirvad/Arpan/Ori Plast)
Supply of heat shrinkable type indoor end jointing kit suitable for XLPE insulated stranded Al. Conductor cable of size 3 core x 120mm2 1100V grade complete with all accessories along with jointing of the HT cable by License holder cable jointer only. (Kit Make: Raychem RPG/Yamuna Densons/ 3M / Polycab)
Wiring of Light, Fan and call bell points with 1.5 sq.mm., PVC insulated 1100V grade FRLSH single core, 15 M/Strand copper wire through suitable size (ISI marked) PVC conduit pipe/casing/concealed way along with ECC of 1no. 1.5 sq.mm. , PVC insulated single core, M/Strand FRLSH copper wire as per General specification of IE Rule. (PVC wire Make:Havells/Gloster/Polycab/RR Kabel/KEI/Mescab) (Switch & Plug Socket Make: Panasonic/ Anchor/ GMModular/ Legrand/Crabtree/ Havells/Hager)
Wiring of 6 Amp plug board consisting with one 6A plug socket and one 6 amp switch by 2 nos. single core FRLSH grade, PVC insulated, copper conductor wire of size 1.5 mm2, 1100V grade for phase and neutral alongwith 1 no. 16 single core FRLSH grade, PVC insulated, copper conductor wire of size 1.5 mm2, 1100V grade for Earth Continuty Conductor (ECC) through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way as per General specification of IE Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab) (Switch & Plug Socket Make: Panasonic/ Anchor/ GMModular/ Legrand/Crabtree/ Havells/Hager)
Wiring of 16 Amp./ 6 pin plug board consisting with one 16A plug socket and one 16 amp switch by 2 nos. single core FRLSH grade, PVC insulated, copper conductor wire of size 4 mm2, 1100V grade for phase and neutral alongwith 17 1 no. single core FRLSH grade, PVC insulated, copper conductor wire of size 2.5 mm2, 1100V grade for Earth Continuty Conductor (ECC) through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way as per General specification of IE Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab) (Switch & Plug Socket Make: Panasonic/ Anchor/ GMModular/ Legrand/Crabtree/ Havells/Hager)
Supply, laying, and termination of sub-main wiring comprising 2 run of 4mm² single-core copper conductor 18 PVC FRLSH insulated wires, along with one run of 2.5mm² copper Earth Continuity Conductor (ECC), through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way as per General specification of IE Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab)
Supply, laying, and termination of main/sub-main wiring comprising 2 run of 6mm² multi-stranded single- 19 core copper conductor PVC FRLSH insulated wires, along with one run of 2.5mm² copper Earth Continuity Conductor (ECC), through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way as per General specification of IE Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab)
Supply, laying, and termination of sub-main wiring comprising 3 run of 4mm² single-core copper conductor PVC FRLSH insulated wires, along with one run of 2.5mm² copper Earth Continuity Conductor (ECC), through G.I. conduit pipe, for shed etc. as per General specification of IE Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab)
Wiring of Sub-main with 4sqmm, 3 core flat PVC insulated 1100V grade as per IS: 694:1990 through suitable size PVC conduit pipe in RCC structure as per General specification of IE Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab)
Supply and laying of copper flexible single core cable of size 185 sq.mm. (Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab)
Supply and laying of copper flexible single core cable of size 70 sq.mm. (Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab)
Supply and fixing of 3 pin, 5 amp, ceiling rose on the supplied metal box of size (75 mm x 75mm x 60 mm deep) on surface or in recess with suitable size of phenolic laminated sheet cover in front, painting etc. as required including 24 electrical connection for Light & Fan points with 2 nos. 1.5 sq.mm, 1100V grade Copper PVC FRLSH, Single core, Multi-strand wire(for phase and neutral) along with 1 no. single core FRLSH PVC insulated copper wire of size 1.5 sq.mm, 1100V grade for ECC through flexible PVC conduit from ceiling rose connected with Sub-main as per General specification of IE Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab) Unit
II-(Non Schedule - LED LUMINARIES) (LED luminaries should cover a warranty of 60 Above/
Design of mounting layout ,Supply, installation for LED street light luminaires of approximately 90W rating, 1 having a minimum luminous efficacy of 120lm/W. The luminaires shall be housed in pressure die-cast aluminium enclosures and conform to minimum IP65 protection rating or higher as per General Specification. Installation/fixing of street light fitting should be made with existing/supplied arm bracket of G.I. pole / Rail pole. (LED Luminaries Make - Bajaj/ Philips/ Havells/Crompton/ Panasonic/ Orient/ Signify/Ecolink)
Design of mounting layout ,Supply, installation for LED street light luminaires of approximately 60W rating, 2 having a minimum luminous efficacy of 120lm/W. The luminaires shall be housed in pressure die-cast aluminium enclosures and conform to minimum IP65 protection rating or higher as per General Specification. Installation/fixing of street light fitting should be made with suitable dia. G. I. bend pipe with G. I. clamps made of G. I. Flat of suitable size & G. I. Nut, bolts etc. (LED Luminaries Make - Bajaj/ Philips/ Havells/Crompton/ Panasonic/ Orient/ Signify/Ecolink)
Design of mounting layout ,Supply, installation of LED Flood light Luminaire 400W(approx), luminaire 3 efficacy>= 130lm/W with high pressure die cast housing complete with all accessories and conform to minimum IP66 protection rating or higher as per General Specification. Installation/fixing should be made with lantern carriage of High Mast Tower/ structure of fabricated Flood light tower / building wall etc. by suitable clamping arrangement etc. (LED Luminaries Make - Bajaj/ Philips/ Havells/Crompton/ Panasonic/ Orient/ Signify/Ecolink)
Design,Supply, installation and mounting layout for integrated LED TUBE LIGHT 4ft. luminaires 1 X 20W (approx.) (Extruded Aluminium LED Batten) (IP:20) (indoor type) as per General Specification including fixing with G. I. clamps made of G. I. Flat of suitable size & G. I. Nut, bolts etc. (LED Luminaries Make - Bajaj/ Philips/ Havells/Crompton/ Panasonic/ Orient/ Signify/Ecolink)
Designing of mounting layout, Supply, installation, connection and commissioning of LED luminaire 4ft., 5 2X18W or above (min. IP:20, indoor type) as per General Specification including batten complete with all accessories including fixing with G. I. clamps made of G. I. Flat of suitable size & G. I. Nut, bolts etc. (LED Luminaries Make - Bajaj/ Philips/ Havells/Crompton/ Panasonic/ Orient/ Signify/Ecolink)
Designing of mounting layout, Supply, installation, connection and commissioning of Bulk Head Luminaire 6 10W with pressure die cast aluminium housing complete with all accessories.(LED luminaire should conform to min:IP:65) as per General Specification including fixing with G. I. clamps made of G. I. Flat of suitable size & G. I. Nut, bolts etc. (LED Luminaries Make - Bajaj/ Philips/ Havells/Crompton/ Panasonic/ Orient/ Signify/Ecolink)
Design,Supply, installation and mounting layout for integrated LED TUBE LIGHT 2ft. luminaires 1 X 20W 7 (approx.) (Extruded PC LED Batten) (IP:65) (indoor type) as per General Specification including fixing with G. I. clamps made of G. I. Flat of suitable size & G. I. Nut, bolts etc. (LED Luminaries Make - Bajaj/ Philips/ Havells/Crompton/ Panasonic/ Orient/ Signify/Ecolink)
Supply, installation, testing & Commissioning of energy efficient, maintenance free Diamond Boards with imported translucent Fibre material 3mm acrylic outdoor material 28 gauge GI sheet with spray print LED fittings, ACP sheet 3mm, 1"X 1" MS pipe with red oxide complete square Signage with all accessories. Unit Above/
III-(Non Schedule - GENERAL ELECTRICAL WORKS)
Supply of wire-mesh cable tray hot deep galvanized of size mm (55HX200WX3000L). (Make: OBO/Legrand/Profab)
Supply of Joint Connector/Corner Connector. (Make: OBO/Legrand/Profab)
Installation of Wire Mess Cable tray by suitable G.I fixtures.
Supply and Fixing of thermoplastic fabricated cable end box, 4 way. As per Sr. DEE/G/SDAH's Drg no.- SDAH/G/4/2024, Dt.- 13.09.2024. Scale: N.T.S (Make: Grasp/Legrand/Hensel/CAPE)
Design, fabrication, supply including transportation, loading/unloading & foundation, erection & 5 commissioning and testing of 20 mtr. high mast tower of polygonal shape suitable for fitment of 16/12 nos. led light fittings, having suitable control circuit ,lightening arrester complete with all integral power tool, control panel navigation light, earthing etc. as per General Specification. (High Mast Tower Make- Transrail/ Crompton/ Bajaj/ Utkarsh/B.P.Project)
Supply and fixing of Wire-mesh Guard of size 29"x6", duly painted, made from 3/4" x 3/4" MS angle and guarded by 10SWG wire duly welded along with 06 Nos fixing flat clamps by necessary GI fixtures.
Supply, fixing, testing and commissioning of star rated BLDC Ceiling fan, 1200mm sweep, 3 blade (Blade 7 material :High grade Aluminium alloy),Service value:Minimum 7.5, 230V, 50 c/s, and all other accessories (With Remote) including fixing of ceiling fan with suitable clamping arrangement &'S' hook etc. as per General Specification.(Make: Havells/ Usha/ Anchor/ Orient/ Crompton/Bajaj/Atomberg)
Supply, Fixing, connection & commissioning of A.C. Exhaust Fan, 300 mm sweep, 230V, 50 c/s complete with all accessories including fixing with G. I. clamps made of G. I. flat of suitable size & G. I. Nut, Bolts alongwith necessary Masonry works. (Make: Havells/ Usha/ Anchor/ Orient/ Crompton/Bajaj)
Supply, Fixing with suitable G.I clamping arrangement, connection and commissioning of AC Wall Bracket Fan,3 blades, 400mm sweep, approx 55W, 230V, 50Hz complete with all accessories. (Make: Havells/ Usha/ Anchor/ Orient/ Crompton/ Bajaj/ Atomberg)
Supply and fixing of 3'' X 3'' PVC Junction Box, Ceiling Rose with Sub main Wiring and necessary connection of Ceiling Rose .
Supply, installation, testing, and commissioning of 3-phase, 4-way TP&N vertical type distribution board 11 (metal double door enclosure, IP:43 rated), comprising the following components: a) 1 No. MCCB, 4-pole, 50-63A, breaking capacity 25kA b) 12 Nos. MCB, single-pole, 16-32A, breaking capacity 10kA The distribution board shall be fixed using suitable ISI-marked G.I. fixtures and accessories, complete in all respects as per site conditions and conforming to relevant IS/IEC standards. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/Havells/Legrand/ Hager)
Supply, installation, testing, and commissioning of SPN 8-way (IP:43) MCB distribution board 12 (surface/concealed mounting type), comprising the following components: a) 1 No. MCB DP 63A, B/cap:10KA, (incoming) b) 6 Nos. MCB SP 10/20A B/cap - 10 KA (outgoing) Work shall include complete wiring terminations, provision of all necessary mounting hardware, accessories, and interconnections, executed as per site conditions and in compliance with IS/IEC standards. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/Havells/Legrand/ Hager)
Supply, installation, testing, and commissioning of single-phase 8-way MCB distribution board (surface/concealed mounting type), comprising the following components: a) 1 No. Double Pole MCB, 32A, 10kA breaking capacity (incoming) b) 6 Nos. Single Pole MCB, 10A, 10kA breaking capacity (outgoing) Work shall include complete incoming and outgoing wiring terminations, provision of all necessary mounting hardware, accessories, and interconnections, executed as per site conditions and in compliance with IS/IEC standards. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/Havells/Legrand/ Hager)
Supply & fixing of Electro Mechanical Timer Switch with Contactor unit of cap. 32A for Half Light & Full Light system for Time Switch complete within enclosure along with connection and testing of the same. (Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/Havells/Legrand/ Hager)
Supply and fixing of multi-plug board for Computer power points with hylam sheet cover consisting of a) Plug Socket 5Pin/6Amp. - 3 nos. b) Piano Switch 6 Amp - 3 nos. c) Plug Socket 6 Pin /16 Amp. - 1 no. d) Piano Switch, 16 Amp - 1 15 no. e) MCB SP 16Amp,B/cap:10KA. - 1 no. f) LED indication lamp - 1no. including wiring with 2.5 mm2 single core, multi strand, PVC FRLS Cu wire through suitable size (ISI marked) PVC conduit pipe/ casing/ concealed way and along with copper ECC of size 1.5mm2 as per General Specification of IE Rule. (PVC Wire Make: Havells/ Gloster/ Polycab/ RR Kabel/KEI/Mescab) (Switch & Plug Socket Make: Panasonic/ Anchor/ GM Modular/ Legrand/Crabtree/Havells/Hager) (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager)
Supply and fixing of Mobile Charging points with hylam sheet cover consisting of a) Plug Socket 5Pin/6Amp. - 3 nos. b) Piano Switch 6 Amp - 3 nos. c) MCB SP 6Amp, B/cap10KA. - 1 no. d) LED indication lamp - 1no, including wiring with 16 2.5 mm2 single core, multi strand, PVC FRLS Cu wire through suitable size (ISI marked) PVC conduit pipe/ casing/ concealed way and along with copper ECC of size 1.5 mm2 as per General Specification of IE Rule. (PVC Wire Make: Havells/ Gloster/ Polycab/ RR Kabel/KEI/Mescab) (Switch & Plug Socket Make: Panasonic/ Anchor/ GM Modular/ Legrand/Crabtree/Havells/Hager) (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager)
Supply of Storage Water Cooler cum purifier with inbuilt UV purification system, Floor mounted, inbuilt 17 stainless steel tank of storage capacity 120 Litre (approx.), having cooling capacity 80 Litre per Hour (approx.) suitable for operation on 1 Phase, 230- 240 Volt, 50 Hz supply system including freight, installation, testing and commissioning as per General Specification. (Make: Eureka Forbes/ Blue Star/Voltas/Kent)
Supply & fixing of AC power unit in enclosure with MCB DP 32A/25A, Starter rating G/H/J or equivalent. (Make: North West/ Lauritz Knudsen /ABB/ Siemens/ Crabtree/Hager)
Design, Supply, Installation, testing and commissioning of MS fabricated wall/floor mounted, hinged type cubicle panel board made of (14 SWG) MS sheet duly powder coated, comprising with the following :- a) MCCB, 320-400A, 4 19 Pole, 415V,B/Cap:36kA - 2 nos., b) MCCB, 250-320A, 4 Pole, 415V,B/Cap:36kA - 2 nos., c) MCCB, 80-100A, 4 Pole, 415V, B/Cap:25kA - 2 nos. d) Copper Busbar 4 bar type, 600A - 1 set including internal electrical connections with suitable size of wire / bar and provision of digital type LT CT operated multifunction energy meter,3 ph,4 wire: 2 nos. ;Digital Ammeters with CT and modular LED indicators etc. along with transportation charges. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager) (Meter Make: Selec/Secure/Lauritz Knudsen/ HPL/Schneider)
Design, Supply, Installation, testing and commissioning of MS fabricated wall/floor mounted, hinged type cubicle panel board made of (14 SWG) MS sheet duly powder coated, comprising with the following :- a) MCCB, 100-125A, 4 20 Pole, 415V,B/Cap:36kA - 2 nos., b) MCCB, 50-63A, 4 Pole, 415V,B/Cap:25kA - 4 nos., c) MCCB, 32-40A, 4 Pole, 415V, B/Cap:25kA - 2 nos. d) Copper Busbar 4 bar type, 200A - 1 set including internal electrical connections with suitable size of wire / bar and provision of digital type voltmeter and Ammeters with CT and modular LED indicators etc. along with transportation charges. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager) (Meter Make: Selec/Secure/Lauritz Knudsen/ HPL/Schneider)
Design, Supply, Installation, testing and commissioning of MS fabricated pillar box (12 SWG) MS sheet duly powder coated, comprising with the following :- a) MCCB 320-400A,4Pole ,B/cap - 36 kA, 415 V, 50 Hz - 02 nos, b) MCCB 250- 21 320A , 4 Pole, B/Cap -36 kA, 415V, 50 Hz -04 nos. c) MCCB 160-200 A , 4 Pole, B/Cap -25 kA, 415V, 50 Hz -02 nos. c) MCCB 80-100 A , 4 Pole, B/Cap -25 kA, 415V, 50 Hz -02 nos. d) Copper Busbar,4bar type, 600A-1set, including internal electrical connection with suitable wires/bars MS Pillar box completed with 4 legs and RCC foundation including LED indication lamp etc. along with transportation charges. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager)
Supply, fabrication, installation, commissioning and testing of Wall mounted outdoor type Glass Fiber Reinforced polyester Enclosure including locking arrangements for providing power supply to AC Coach Precooling arrangements consisting with the following (1)125A, 5-pin, 3-phase, 50Hz industrial plug socket assembly - 01 set (2) MCCB 22 125A, 4-pole, B/Cap-36 KA-01 No (3) 20A, 3-pin, 1- phase, 50Hz. industrial plug socket assembly - 01 Set iv) MCB DP 20A-01 No Industrial Plug Socket Assembly made of PA 6 material confirming to IS/IEC 60309 1 & 2,IP Rating IP 44 and IP 67. Along with internal connection by 50 mm of copper wire, socketing etc. and provision of power Cable (120 mm2 PVC XLPE Armoured Cable) loop in and loop out arrangement with proper rated grommets. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager) (Panel Make: CAPE/ Hensel/ Legrand/ Grasp/ VSMPlast/ Pepperl+Fuchs)
Supply, installation, testing, and commissioning of 4-pole MCCB rated for 80-100A, 415V, with a breaking 23 capacity of 25kA, housed in a suitable sheet steel enclosure. Work shall includes all mounting accessories, terminations, and enclosure fixing as per site conditions, conforming to IS/IEC standards. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager)
Supply, installation, testing, and commissioning of 4-pole MCCB rated for 320-400A, 415V, with a breaking 24 capacity of 36kA, housed in a suitable sheet steel enclosure. Work shall includes all mounting accessories, terminations, and enclosure fixing as per site conditions, conforming to IS/IEC standards. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager)
Shifting of CSS with booster transformer after dismantling including plinth construction along with new 25 construction of iron shed structure with transparent sheet top cover and MS grill structure duly painted at four sides of CSS and Transformer.
Supply, installation, testing and commissioning of FEEDER PILLAR BOX: 630A, 4 pole, 70 KA, MCCB (02 nos) 26 and Microprocessor Based release for O/L, S/C Protection- 02 nos. for 750V LT supply system, alongwith provision of metering arrangement of volt, Amp, KWh, frequency with R-Y-B indication with proper C.T. arrangement (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager)
Dismantling of ZS coupler box and deposited to consignee store.
Dismantling of FEEDER PILLAR BOX of 750 Volt with 01 no 630A MCCB and deposited to consignee store.
Supply, fixing, testing and commissioning of Busbar chamber of 800 Amp., 750 Volt, (4 bar type) suitable for 10 nos LT 4C x 300 mm2 cables. (Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager/Standard)
Supply, fixing & commissioning of portable type water proof ZS coupler box 600 A, 750V by 3 mm CRC sheet, powder coating (Siemens grey paint) of size (600 x 600 x 500 mm) which will be hanged from catwalk with suitable clamping arrangement. (ZS Coupler will be supplied by Rly.)
Supply & Fixing of 75 mm dia PVC flame proof special type flexible black pipe.
Supply & Fixing of flame proof special type pvc coupler for the above PVC pipe of size 75mm dia.
Supply, fixing and commissioning of heavy duty copper flat type socket with the copper cable of size 185 sq.mm. and PVC tape paste etc. by crimping method.
Supply, fixing and commissioning of heavy duty copper flat type socket with the copper cable of size 70 sq.mm. and PVC tape paste etc. by crimping method .
Dismantling of 4 core X 300 sq.mm XLPE cable from Pucca duct and deposited to consignee store.
Supply & connection of LT cable socketting & connection with gland for 4 core 300 sq. min cable
Supply of Digital LT Megger, 500V, 1000 Mega Ohm. (Make: Shanti/Rishabh/Megger/Meco/Fluke)
Supply of Digital HT Megger, 2500V, 5000 Mega Ohm (Make: Shanti/Rishabh/Megger/Meco/Fluke)
Supply of 4 digit Backlit LCD hand held True RMS clamp meter of voltage range 1000V, complete with all accessories. (Make: Metravi/Bosch/Megger/Fluke/Meco/Stanley)
Supply of 4 digit LCD display Auto ranging Digital Earth Resistance Meter, complete with all accessories. (Make: Metravi/Bosch/Megger/Fluke/Meco/Stanley/HTC)
Supply of laser distance meter 100 meter range , complete with all accessories. (Make: Metravi/Bosch/Megger/Fluke/Meco/Stanley/De-walt)
Supply and installation of medium duty GI Earth Pipe of 50 mm dia., 3 Mtr. long, including proper connection with 8 SWG GI wire using suitable clamps and fasteners etc., complete with testing, commissioning, and in conformity with relevant IS codes, electrical safety standards. (G.I.Pipe Make: Tata/Jindal/Bansal)
Supply and installation of G.I. strip of size 25 mm x 3 mm (thick), fixed along walls by grouting suitable size 43 bolts with nuts at 450 mm intervals for earthing, including provision of necessary connections. The G.I. strip shall be separated from the wall using suitable size insulators with the bolts. The work shall be completed with testing and commissioning, strictly in accordance with relevant IS codes, electrical safety standards.
Supply and installation of G.I. strip of size 40 mm x 6 mm (thick), fixed along walls by grouting suitable size 44 bolts with nuts at 450 mm intervals for earthing, including provision of necessary connections. The G.I. strip shall be separated from the wall using suitable size insulators with the bolts. The work shall be completed with testing and commissioning, strictly in accordance with relevant IS codes, electrical safety standards.
Supply and installation of GI Standard Earth pipe, 40 mm dia, 2000 mm long, medium gauge complete with 45 provision of Earth pit and there connection with 4 SWG GI wire complete with testing and commissioning, strictly in accordance with relevant IS codes, electrical safety standards.as per Sr. DEE(G)/SDAH's Drg. No. SDAH/G/MISC/47 dt.21.11.2008(Alt-1). (G.I.Pipe Make: Tata/Jindal/Bansal)
Supply, erection, testing & commissioning of Earthing System with provision of 03 nos. GI standard Earth 46 pipe of heavy gauge 2 inch dia, 2500 mm long complete with 01 no. earth pit, masonry work for Earth pit, pit cover, clamping connection of earth spikes as per Sr. DEE(G)/SDAH's Drg. no. SDAH/G/SS/113 dt. 06.03.09. (G.I.Pipe Make: Tata/Jindal/Bansal)
Earthing work using two Nos. of 50 mm dia., 2.5 Mtr. long heavy gauge GI Pipe, including construction of 47 earth pit with all associated works, along with providing and fixing necessary earth connections from pit using 25 mm x 4 mm GI flat with GI nuts & bolts etc., complete with testing and commissioning, strictly in accordance with relevant IS codes, electrical safety standards. (G.I.Pipe Make: Tata/Jindal/Bansal)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf
ATTACHMENT
LEDluminariesSpecifications.pdf
ATTACHMENT
FormatofGuaranteeBond_1.pdf
ATTACHMENT
LTHTElectricalBooklet_1.pdf
ATTACHMENT
GCC-April-2022_1.pdf
ATTACHMENT
2022_CE-I_CT_GCC-2022Policy14_07_20221_1.pdf
ATTACHMENT
OpenTenderDocument_2.pdf
ATTACHMENT
OpenTenderDocument_1.pdf
ATTACHMENT
Download all tender documents and submit your bid