| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.9 CrAccepted-AOC | ₹6.9 Cr | L-1 | Accepted-AOC L-1Bidder |
| 2 | L-2₹13.4 Cr+₹6.4 Cr (92.8%)Rejected-Finance | ₹13.4 Cr+₹6.4 Cr (92.8%) | L-2 | Rejected-Finance Other than L-1Bidder |
| 3 | L-3₹14.0 Cr+₹7.0 Cr (101.1%)Rejected-Finance GOKUL APARTMENTS BLOCK C SHIVMANDIR ROAD PUNJABI PARA SILIGURI 734 401 WEST BENGAL | SILIGURI | WEST BENGAL | 734401 | ₹14.0 Cr+₹7.0 Cr (101.1%) | L-3 | Rejected-Finance Other than L-1Bidder |
Tender Value
Refer Docs
EMD Value
₹8.0 L
Closing Date
21 May 2021, 6:00 pmClosed
HQ CE SILIGURI ZONE
HQ CE Siliguri Zone Siliguri, Sevoke Road, PO Salagura Dist Jalpaiguri, West Bengal PIN 734008
REPAIR/RECTIFICATION OF OUTSTANDING DEFECTS IN MAP QTRS (PHASE-II) AT SEVOKE AND SUKNA
2021_MES_427555_1
98714/MAP/SEV/SZ/E8
Open Tender
Civil Works
Item Rate
730 days
GE SEVOKE ROAD AND GE SUKNA
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,000
GE SEVOKE ROAD
₹8.0 L
Yes
3 Jul 2021
3 Mar 2021
24 May 2021
3 Mar 2021
21 May 2021
30 Apr 2021
3 Mar 2021 - 12 Mar 2021
Amount
Demolition of cement concrete (Unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing debries to a distance exc. 250 mtrs and not exc 500 mtrs complete all as specified and as directed.
M&L for 100 mm thick Cement concrete type B2, (1:2:4) (using 40 mm graded stone aggregate) in sub base of flooring complete all as specified and as directed.
M&L for 50 mm thick Cement concrete type B1, (1:2:4) (using 20 mm graded stone aggregate) as in flooring finished even and fair without using extra cement mixedc with WPC as per manufacturers instructions complete all as specified and as directed. Note:- WPC shall be measured and paid seperately under appropiate item.
M&L for Forming 20 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’. complete all as specified and as directed.
Supply only integral water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed.
M&L for 15mm thick plaster of cement mortar (1:4) rendering on other than fair faces of brick work finishing the surface fair and even without using extra cement complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position and removing debries to a distance exc. 250 mtrs and not exc 500 mtrs complete all as specified and as directed.
Demolition of brick work built in cement mortar of any description and removing debries to a distance exc. 250 mtrs and not exc 500 mtrs complete all as specified and as directed.
M&L for brickwork with sub class B bricks straight or curved on plan exc 6mtr mean radius built in cement mortar (1:6) by using old size bricks complete all as specified and as directed.
Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and as directed.
M&L for 12mm thick rendering in cement mortar 1:6 on fair face of brick work or concrete surface finished even & smooth (without using extra cement) complete all as specified and directed.
M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm & 5mm) mixed with water proofing compound in top layer @3% by the weight of cement or as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and as directed. Note:- WPC shall be measured and paid seperately under appropiate item.
M&L for rendering 5mm thick plastering in CM (1:3) on ceiling, soffits of slabs, chajjas, columns and beams etc and finished the plastered surface even and smooth without using extra cement.complete all as specified and as directed.
M&L for Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
M&L for prepartion of newly plastered surfaces of walls and applying two coats of oil bound distemper over 2mm thick of wall care putty and a coat of primer including necessary preperation of surfaces complete all as specified and directed.
M&L for complete removal of existing treated surfaces of walls including cornices, pillasters and other wall feathers etc by washing rubbing down and stopping of distempered and painted surfaces and applying two coats of oil bound distemper over a coat of primer including necessary preperation of surfaces, complete all as specified and directed.
M&L for preparing new Plastered surfaces of walls, Chajja/Fasia etc surfaces and applying two coats of weather proof Acrylic Exterior emulsion paint of approved make and shade over a coat of Acrylic emulsion primer complete all as specified and directed.
M&L for preparing new Plastered surfaces of walls, Chajja/Fasia etc surfaces and applying two coats of weather proof Acrylic Exterior emulsion paint of approved make and shade over 2mm thick of wall care putty and a coat of Acrylic emulsion primer complete all as specified and directed.
M&L for complete removal of existing treated surfaces of walls including cornices, pillasters and other wall feathers etc by washing rubbing down and stopping of painted surfaces, preparing old Plastered surfaces of walls, Chajja/Fasia etc surfaces and applying two coats of weather proof Acrylic Exterior emulsion paint of approved make and shade over a coat of Acrylic emulsion primer complete all as specified and directed.
M&L for complete removal of existing treated surfaces of walls including cornices, pillasters and other wall feathers etc by washing rubbing down and stopping of painted surfaces, preparing old Plastered surfaces of walls, Chajja/Fasia etc surfaces and applying two coats of weather proof Acrylic Exterior emulsion paint of approved make and shade over 2mm thick of wall care putty and a coat of Acrylic emulsion primer complete all as specified and directed.
M&L preparing newly plastered or unplastered surfaces of ceiling and applying three coats of white washing complete all as specified and directed.
M&L for preparartion of old ceiling surfaces and applying one coat of white washing complete all as specified and as directed.
M&L for preparartion of old surfaces of walls and applying two coats of white washing complete all as specified and as directed.
M&L preparing newly plastered or unplastered surfaces of walls and applying three coats of white washing complete all as specified and directed.
M&L for Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over and including 20mm thick screed bed laid in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
M&L for Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over and including 10mm thick screed bed laid in cement mortar 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
M&L for coloured Non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floor etc set and jointed in neat cement slurry over and including 15mm thick screed bed for laying floor finishes in Cement mortar (1:6) complete all as specified and as directed.
M&L for coloured Glazed ceramic tiles 300mm x 200mm x 7mm (Square/rectangular)as in vertical surfaces set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick screed bed for laying floor finishes in Cement mortar (1:4) complete all as specified and as directed.
M&L for sunken floor treatment by roughening of sides and bottom of sunken floor by picking, sweeping clan and washing down with water to remove dust, dirt etc and rendering 6mm thick plaster in cement mortar 1:4 on concrete surfaces (bottom sides of sunken floor) mixed with liquid water proofing compound as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and as directed.
Taking up or down GI 15mm bore concealed pipe and connection complete all as specified and as directed.
Taking up or down GI 20mm steel tubing and connections complete all as specified and as directed.
Taking up or down GI 25mm steel tubing and connections complete all as specified and as directed.
S&F of 15mm bore pipe medium grade galvanised iron water tube with all fittings concealed laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F of 20mm bore pipe medium grade galvanised iron water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F of 25mm bore pipe medium grade galvanised iron water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning the reuseable pipe for refixing (measured overall as fixed along the centre line over fittings and accessories)
S & F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
Fixing only 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints with PVC Solvent glue after necessary cleaning fixed to walls complete all as specified and as directed. Note:- Reuseable pipes obtained from item mentioned here-in-above.
S&F of 110mm dia PVC (SWR) bends of any radius complete all as specified and as directed.
S&F of 110mm dia PVC (SWR) branch piece single (single Y/ T) equal or unequal with acess door complete all as specified and as directed.
S&F of 110mm dia PVC (SWR) vent cowl complete all as specified and as directed.
S&F of 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
Fixing only 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints with PVC Solvent glue after necessary cleaning fixed to walls complete all as specified and as directed. Note:- Reuseable pipes obtained from item mentioned here-in-above.
S&F of 75mm dia PVC (SWR) bends of any radius complete all as specified and as directed.
S&F of 75mm dia PVC (SWR) branch piece single (single Y/ T) equal or unequal with acess door complete all as specified and as directed.
S&F of 75 mm bore PVC (SWR) Vent Cowl complete all as specified and as directed.
M&L for 20mm thick plaster of cement mortar (1:4) rendering on concrete roof surfaces mixed with water proofing compound as per manufacturer's instructions and finishing the surface fair and even without using extra cement complete all as specified and as directed. Note:- WPC shall be measured and paid seperately under appropiate item.
M&L for reinforced Precast cement concrete (1:2:4), type B1 (Using 20 mm graded stone aggregate)as in cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar (1:6) complete all as specified and as directed. Note:- Reinfocements will be measured and paid seperately under appropiate item
M&L for TMT bar 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with screws complete all as specified and as directed.
M&L for 18/19mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work as in cupboard shelves complete all as specified and as directed.
S&F in repair, 100mm aluminum anodised, Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed.
S&F in repairs, Continuous (piano) hinges,30mm Width of flaps (when open) in mm mild steel, bright finish or electrogalvanised complete all as specified and directed
M&L for preparation of old wooden surface of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed.
M&L for Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high complete all as specified and as directed.
S&F in repair 15mm CP brass wall mixer (3 in 1) with provision for fore head shower with long bend pipe, connecting legs and wall flanges with 125mm size hand shower with suitable flexible CP pipe of 1.5 mtrs length and fixed complete all as specified and directed.
M&L for water proofing compound as a plugging compound as per speciication 80cm centre to centre after cleaning of total surface area and make dry and opening of cracked area and drilling upto 25mm depth in walls and floor includng all necessary tools all as manufacturers instructions complete all as specified and as directed.
M&L for injecting and grouting the cement mixed with expending grout, Non Shrink Polymeric Water Proofing Grouting Compound plugg sealed with food grade epoxy putty including all necessary tools and tackless upto overflow of slurry into outside and inside surfaces complete all as specified and as directed.
M&L for applying by brush acrylic polymer modified cementation compound in ratio 1:2 (i.e 1 part chemical and 2 part cement) in two coats at an interval of minimum 8 hours on the wall and floors in tank over area outside and inside includng all necessary tools all as manufacturers instructions complete all as specified and as directed.
M&L for fibre wire mesh 0.56mm nominal dia and average with of apperature 2mm dia aincluding all laps cutting and waste all includng all necessary tools all as manufacturers instructions complete all as specified and as directed.
M&L for 15mm thick cement plaster on internal concrete surfaces of semi undergroung sump in cement mortar (1:3) in two layers (10mm & 5mm) mixed with and including water proofing compound as per manufacturer's instructions and finishing the surface fair and even without using extra cement complete all as specified and as directed.
Taking down shutter of any description exceeding 1 sqm and not exceeding 2 sqm each complete all as specified and as directed.
Taking down chowkat with shutter exceeding 1.5 sqm and not exceeding 4.00sqm each complete all as specified and as directed.
Refixing shutter of any description but exceeding 1 sqm and not exceeding 2 sqm each in same opeining etc complete all as specified and as directed.
Taking down chowkat with shutter not exceeding 1.5 sqm each complete all as specified and as directed.
S&F Solid PVC Door Frame of size 60mm x 50mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as specified in Section 8 of SSR Part II, complete all as specified and directed.
S&F solid PVC profile door shutter of 28mm thick and 71mm wide rail and styles made of solid PVC foam profile with a fine homigeneous cellular structure having smooth surface 3.3mm thick (2.8mm PVC foam sheet is laminated on both side with 0.25mm rigid PVC sheet) extra strength PVC panel, stiles, rails and decorative beading of size 12mm x 12mm are jointed together using solvent cement , all corners of PVC profile are first mitred cut and then welded complete all as specified and as directed.
S&F mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F of pressed steel frames for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc. size of frame 124mm x 45mm complete all as specified and as directed.
M & L for providing plain cement concrete type C-1, (1:3:6), (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
S&F of 100 mm MS steel butt hinges, heavy weight, complete all as specified and as directed.
S&F of aluminium anodised barrel tower bolts of extruded section150mm long complete all as specified and as directed.
M&L for sliding door bolt of 300mm long plate Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F of 150mm size Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed.
M&L for preparation of old steel surfaces of any description over 10cm in width or girth not otherwise described applying one coats of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description not exc 10cm in width or girth not otherwise described applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed.
S&F of 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F in repairs vitreous china wash basin, white, flat back, size 550x400m excluding taps, waste , chain & plug & porcelain stopper including including cutting for and pinning in ends of brackets or erecting stand, brackets complete all as specified and directed
S&F in repair 32 mm bore Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed.
S&F in repair 15mm bore pillar taps, cast copper alloy with capston heads, chromium plated, fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed..
S&F 15 mm bore angle cock brass chromium plated, fancy type with flange complete all as specified and directed.
S&F 15mm bore bib taps, cast copper alloy chromimum plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F in repair 15mm bore basin mixer Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixedcomplete all as specified and as directed.
S&F chromimum plated health faucet with 1/1.5 meter tube and hook complete all as specified and directed.
S&F 15 mm bore two way bib cock, brass chromium plated, fancy type with flange complete all as specified and direcrted.
M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and direcrted.
M&L for Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area exc 400 sqm, Exc 50 mm and not exc 100 mm deep complete all as specified and as directed.
M&L for 150 mm thick (compacted thickness) WBM, with 2 layer of 75 mm thick in each thickness with coarse aggregates of grading 2(63 to 40mm size), spread, rolled and consolidated to gradient and camber required using limestone, sandstone flint or quartzite complete all as specified and as directed.
M&L for preparing un-surfaced water bound macadam by brushing with wire brushes for removing caked mud etc., sweeping with brooms & finally fanning the cleaned surfaces with gunny bags to remove all loose dirts etc. over WBM surface complete all as specified and as directed.
M&L for Applying evenly a priming/tack coat with paving bituminous primer at 10 kg per 10 sq metre complete all as specified and as directed.
M&L for paving bituminous premixed aspheltic semi dense concrete 40mm consolidated thickness (minimum) with 5.5% binder content of paving bitumen (VG-30) by weight of total mix, rolled and compacted, mixed in mechanical hot mix plant and pre-mix material laid with mechanical paver, finished including rolling to required gradient and camber with 8 to 12 tonne power roller to required compaction complete all as specified in the relevant clauses of SSR Part-I (2009) complete all as specified and as directed
Excavation in trenches not exceeding 1.5m wide and n.exc 1.5m in depth for laying of cables etc and getting out hard / dense soil complete all as specified and as directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed.
Refixing of 15 mm old GI steel tubing and connection in new or old position (wall, ceiling, floor etc) complete all as specified and as directed.
M&L for PCC (1:5:10) type E-2 (using 40 mm graded trap stone aggregate) as in sunken portion complete all as specified and as directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in mass concrete complete all as specified and as directed.
M&L for coloured Non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floor etc set and jointed in neat cement slurry over and including 20mm thick screed bed for laying floor finishes in Cement mortar (1:6) complete all as specified and as directed.
M&L for coloured Glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450x 350x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and pointed in white or colour cement to match over and including 10mm thick screed bed for laying floor finishes in Cement mortar (1:3) complete all as specified and as directed.
S&F in repair vitreous china EWC (Pedestal pattern) with tarp white, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc.. complete all as specified and as directed.
S&F in repair PVC seat cover for pedestal pan, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminiumised hanging device complete all as specified and as directed.
S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed.
M&L for Cement concrete (1:3:6) in surface channels and drains , type C2 (Using 40 mm graded stone aggregate) complete all as specified and as directed.
M&L for 100mm bore Concrete bed in cement concrete 1:4:8 Type D2 (40mm graded aggregate) to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and as directed.
M&L for 15mm thick rendering with cement mortar (1:3) on fair faces of brick work finishing the surface fair and even without using extra cement complete all as specified and as directed.
Dismantling/taking out of PVC (SWR) pipes including fittings of any decription from trenches(if required in foul condition) complete all as specified and as directed.
M&L for prepartion of newly plastered surfaces of walls and applying two coats of oil bound distemper over 2mm thick of wall care putty and a coat of primer including necessary preperation of surfaces complete all as specified and directed.
Demolition of cement concrete (Unreinforced) of any description and in any position complete all as specified and as directed.
M&L for PCC (1:3:6) type B-1 (using 20 mm graded stone aggregate) as in mass concrete for pipe encasing at sunken portion/mass concrete complete all as specified and as directed.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in sunken floor complete all as specified and as directed.
M&L for sunken floor and walls treatment by brushing concrete surfaces (bottom sides of sunken floor) with neat cement slurry @ 0.5 Kg/Sqm mixed with arcylic based polymer modified cememt composite pidifin 2K @ 0.5Kg/Sqm complete all as specified and as directed.
M&L for damaged roof treatment after removal of existing treatment including padding, cleaning the surfaces using wire brushes, bromming down and applying the following course of treatment/specification:- (i) Claen the RCC slab surfaces including sides upto 300mm high by wire brushes , raking and cleaning of construction joints if any (ii) Applying a coat of neat cement slurry mixed with approved water proofing compound as per manufacturers instruction over RCC slab and sides upto 300mm high. (iii) Rendering 20mm thick in CM (1:4) on existing roof surface true to level mixed with approved water proofing compound as per manufacturers instruction
M&L for Brickwork with sub class B bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 including provision of 2 Nos 8mm dia TMT bars at every fourth course complete all as specified and as directed.
M&L for coloured Glazed ceramic tiles 300mm x 200mm x 7mm (Square/rectangular)as in vertical surfaces set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick screed bed for laying floor finishes in Cement mortar (1:3) complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M&L for Forming letters, figures etc. by cutting 'V grooves in new lime, cement plaster (per cm of height) complete all as specified and as directed.
M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed.
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10sq mm 4 core complete all as specified and as directed.
M&L for properly termination of street light UG cable using compression type brass cable glands and dowels make lugs with street light junction boxes bus bar and connecting to existing MCB SP 6 Amps with individual pole street light connection wires complete all as specified and as directed.
S&F MCCB 4P with thermal magnetic release, having breaking capacity 25/26 KA of rating 32 Amps including electric connections in existing in street light LT panel complete all as specified and as directed.
S& F modular 24 Hours, multifunctional, digital timmer switches controlling one phase, 12 to 230 volts, AC 50/60Hz, in existing in street light LT panel complete all as specified and as directed.
S&F 3 pole contactor, 32 Amps with intigrated auxilary contacts 2N0 + 2NC having screws terminals complete all as specified and as directed.
Supply, installation, testing and commissioning of totally enclosed dust and vermin proof (IP 54 Ingress Protection) low impedence compact sandwitch type with Aluminum bus bar rated for insulation voltage of 1.1 KV, 4 Nos, 400Amps aluminum conductor (Strip) 3 Phase + 1 neutral having provision of tapping power as required and including the cost of all required acessories like clamps, elbows, end cover flexible connection etc and including the cost of providing 2 Nos 25mm x 6mm GI earth strip for body earthing and including the cost of expansion joint complete all as specified and as directed.
Supply, fix, testing and commisioning of 63 Amps TPN tab off box complete 63 Amps tpn 25 KA MCCB with cable entry box, cable glazed fixing omplete all as specified and as directed.
M&L 50mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
M&L for maintaince/servicing of Solar water heater of capacity 750 liters with cleaning of tanks, refilling of distill water and replacement of PUF insulation, fixing leakages and replacements of unserviceable parts complete all as specified and as directed. Note:- (i) Repair of Solar water heater shall be carried out through authorized agency/OEM of Solar Water Heater (ii) S&F Solar water tank and collector plate will be measured and paid seperately under appropiate item here-in-below (iii) All other minor repair is deemed to be included in Unit quoted rates
M&L for maintaince/servicing of Solar water heater of capacity 600 liters with cleaning of tanks, refilling of distill water and replacement of PUF insulation, fixing leakages and replacements of unserviceable parts complete all as specified and as directed. Note:- Repair of Solar water heater shall be carried out through authorized agency/OEM of Solar Water Heater (ii) S&F Solar water tank and collector plate will be measured and paid seperately under appropiate item here-in-below (iii) All other minor repair is deemed to be included in Unit quoted rates
M&L for maintaince/servicing of Solar water heater of capacity 500 liters with cleaning of tanks, refilling of distill water and replacement of PUF insulation, fixing leakages and replacements of unserviceable parts complete all as specified and as directed. Note:- Repair of Solar water heater shall be carried out through authorized agency/OEM of Solar Water Heater (ii) S&F Solar water tank and collector plate will be measured and paid seperately under appropiate item here-in-below (iii) All other minor repair is deemed to be included in Unit quoted rates
M&L for maintaince/servicing of Solar water heater of capacity 400 liters with cleaning of tanks, refilling of distill water and replacement of PUF insulation, fixing leakages and replacements of unserviceable parts complete all as specified and as directed. Note:- Repair of Solar water heater shall be carried out through authorized agency/OEM of Solar Water Heater (ii) S&F Solar water tank and collector plate will be measured and paid seperately under appropiate item here-in-below (iii) All other minor repair is deemed to be included in Unit quoted rates
M&L for maintaince/servicing of Solar water heater of capacity 350 liters with cleaning of tanks, refilling of distill water and replacement of PUF insulation, fixing leakages and replacements of unserviceable parts complete all as specified and as directed. Note:- Repair of Solar water heater shall be carried out through authorized agency/OEM of Solar Water Heater (ii) S&F Solar water tank and collector plate will be measured and paid seperately under appropiate item here-in-below (iii) All other minor repair is deemed to be included in Unit quoted rates
M&L for maintaince/servicing of Solar water heater capacity 300 liters with cleaning of tanks, refilling of distill water and replacement of PUF insulation, fixing leakages and replacements of unserviceable parts complete all as specified and as directed. Note:- Repair of Solar water heater shall be carried out through authorized agency/OEM of Solar Water Heater (ii) S&F Solar water tank and collector plate will be measured and paid seperately under appropiate item here-in-below (iii) All other minor repair is deemed to be included in Unit quoted rates.
S&F Solar water tank of 750 ltrs capacity complete all as specified and directed.
S&F Solar water tank of 600 ltrs capacity complete all as specified and directed.
S&F Solar water tank of 500 ltrs capacity complete all as specified and directed.
S&F Solar water tank of 400 ltrs capacity complete all as specified and directed.
S&F Solar water tank of 350 ltrs capacity complete all as specified and directed.
S&F collector plate of size 208mm x 1070mm x 100mm including cover plate made out of toughened glass 4mm thick as per existing complete all as specified and directed.
S&F of break Glass open type MS Hose box for wall hung type 16 SWG CRCA sheet of size 750mm x 600mm x 250mm size with double door, front glass door, suitable to accommodate 2 Nos x 15 mtrs hose reels with MS angles stand/brackets complete all as specified and as directed.
Taking out existing 25mm x 3.15mm aluminum strip from the existing position and refixing the same using using insulated saddles and fixing screws upto the test point complete all as specified and as directed.
M&L for Lagging to pipes used in internal hot water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 complete all as specified and as directed.
M&L for Lagging to pipes used in internal hot water supply or plumbing all round with, 20min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 complete all as specified and as directed.
M&L for Lagging to pipes used in internal hot water supply or plumbing all round with, 15min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 complete all as specified and as directed.
Taking out existing surface fitted 5/15 Amps socket box for solar water heater and in lift room and concealing it including fixing connected items with proper surface finish as original one complete all as specified and as directed.
Taking out existing surface mounted point wiring and making it concealed including all connected acessories and making good surfaces complete all as specified and as directed.
Taking out unserviceable items in lift control panel and fixing serviceable items complete including accessories required other than below mentioned items complete all as specified and as directed. Note:- Repair of Lift shall be carried out through authorized agency/OEM of Lift.
Supply only ARD announcement complete all as specified and as directed.
Supply only lift car light complete all as specified and as directed.
Supply only V 7 Charge card complete all as specified and as directed.
Supply only battery 12 volts 17AH complete all as specified and as directed.
Supply only OSG rope complete all as specified and as directed.
Supply only fireman switch glass complete all as specified and as directed.
Repair of leakage of water storage tank of thermosyphonic Solar water heater by brazing/shoulsering as per manufacturers instructions and making joints/cracks leak proof and testing for 300 LPD capacity Solar Water heater complete all as specified and as directed.
Taking down of thermosyphonic Solar water heater of capacity 300 LPD from its existing position of any make duly disconnected inlet/outlet water connection, transporting to repair workshop if required and including opening up solar water heater for replacement of defective parts and refixed on its existing position and including testing complete all as specified and as directed.
Taking down existing GI pipe of 20mm bore and refixing the same after carrying out repairs with all fittings complete all as specified and as directed.
Cleaning of PVC water storage tank of 500ltrs capacity with wire brush, washing with bleaching powder and clean washing with water complete all as specified and as directed.
S&F Solar Flat Plate Collector 300 LPD with existing connection and including testing complete all as specified and as directed.
S&F Solar Flat Hot Water Storage tank 300 LPD with existing connection and including testing complete all as specified and as directed.
M&L in repair PVC pipes 25mm bore, fixed to wall, celings etc including fittings complete all as specified and as directed.
Reparing of broken MS structue of Solar Water heater of capacity 200/300 LPD as per manufacturers instructions of any make including testing complete all as specified and as directed.
M&L for insulation of Solar Hot Water srorage tank 200/300 LPD and distribution pipeline complete all as specified and as directed.
M&L for hot water rubber hose pipe including external connections, hose crimping etc. complete all as specified and as directed.
M&L for make up tank (MT) with air release valve connection to hot water storage tank complete all as specified and as directed.
AKM CONSTRUCTION AND ENGINEERING LLP
M/s KASHMIRA SINGH BARMI AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .