Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
6 Aug 2020, 6:00 pmClosed
MR ARJUN PATRO
GE U ELECTRIC SUPPLY DELHI CANTT-10
Repair replacement and maintenance of LT Panels MCCB ACB change over switch earthing at CVD Piru Vihar DIPAC HQ TG Vikram Batra Line CMP Line Chitral Line,Basantar Line EME Unit Line Kabul Line Baird Place Kotwali Line DEDZ Office Area Account Offi
2020_MES_359553_1
GE ELECT/D-52/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹98,000
Yes
11 Aug 2020
17 Jul 2020
8 Aug 2020
18 Jul 2020
6 Aug 2020
1 Aug 2020
Amount
OUTGOINGS:- (i) MCCB 4 pole, 250 Amps, 50 Hz, 415 Volts, 36 KA Adjustable Thermal and Adjustable Magnetic setting- 2 Nos (ii) MCCB 4 pole, 100 Amps, 50 Hz, 415 Volts, 35 KA Adjustable Thermo and Fixed Magnetic setting - 1 No (iii) MCCB 4 pole, 400 Amps, 50 Hz, 415 volts, 36 KA, adjustable therma setting-02 Nos. Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. Note :- (i) Location- Near Mother Dairy Kabul line transformer, near SF Qtrs transformer (ii) Location cannot be changed without permission of GE, approval of GE is mandatory for any changing in location.
(b) OUTGOINGS (i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 250 Amps, 35 KA , Adjustable Thermal and Fixed Magnetic setting - 02 Nos. (ii) MCCB 100 Amps 4 pole - 01 No. (iii) MCCB 4 pole, 315 Amps, 50 Hz, 415 volts, 36 KA, adjustable thermal setting-01 Nos. Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. Note :- Location - Behind GE (C), near Gopinath circle (ii) Location cannot be changed without permission of GE, approval of GE is mandatory for any changing in location.
(b) Outgoing :-(i) MCCB 4 pole, 415 Volts, 50 Hz AC of capacity 250 Amps rating 36 KA , Adjustable Thermal and Adjustable Magnetic setting - 02 Nos” (i) MCCB 4 pole, 415 Volts, 50 Hz AC of capacity 100 Amps rating 36 KA rupturing capacity Adjustable Thermal and Fixed Magnetic setting - 2 Nos” Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. Note :- (i) Location-near block No P-51 Kabul line and near block No P-41 Kabul line (ii) Location cannot be changed without permission of GE, approval of GE is mandatory for any changing in location.
(b) Outgoing (i) MCCB 4 pole, 415 Volts, 50 Hz AC of capacity 630 Amps, 36 KA, Adjustable Thermal and Adjustable Magnetic setting- 5 Nos” (ii) MCCB 4 pole, 415 Volts, 50 Hz AC of capacity 100 Amps, 25 KA, Adjustable Thermal and Fixed Magnetic setting - 2 Nos” Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. Note :- (i) Location-near block No P-52 Officer Enclave Baird Place transformer (ii) Location cannot be changed without permission of GE, approval of GE is mandatory for any changing in location.
(b) Outgoing :-(i) MCCB 4 pole, 100 Amps, 50 Hz, 415 Volts, 35 KA , Adjustable Thermal and Fixed Magnetic setting -7 Nos. (ii) Space for MCCB 4 pole, 100 Amps, 50 Hz, 415 Volts, - 1 No Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. Note :- Location -(i)(near CMP Qtrs old chitral line P-01 and near CWE office STP transformer) (ii) Location cannot be changed without permission of GE, approval of GE is mandatory for any changing in location.
(b) Outgoing :(i) MCCB 4 pole, 415 Volts, 50 Hz AC of capacity 320 Amps 36 KA , Adjustable Thermo and Adjustable Magnetic setting- 2 No” (ii) MCCB 4 pole, 415 Volts, 50 Hz AC of capacity 250 Amps rating 36 KA rupturing capacity , Adjustable Thermo and Adjustable Magnetic setting- 01 Nos” (ii) Supply and fixing On load change over switch of capacity 630 Amps, four pole, 415 volts, AC, 50 Hz. - 1 No. (iii) MCCB 4 pole, 100 Amps, 50 Hz, 415 volts, 25 KA, Adjustable thermal setting-01 Nos. Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. Note :- Location-(i) Near Old Baird place officer enclave P-31 and near Kotwali officer enclave P-29) (ii) Location cannot be changed without permission of GE, approval of GE is mandatory for any changing in location.
(b) Outgoing :- (i) MCCB 4 pole, 400 Amps, 50 Hz, 415 Volts, 36 KA , Adjustable Thermal and Adjustable Magnetic setting-1 Nos. (i) MCCB 4 pole, 250 Amps, Adjustable Thermal and Fixed Magnetic setting, 50 Hz, 415 Volts, 35 KA -02 Nos. (ii) MCCB 4 pole, 100 Amps, Adjustable Thermal and Fixed Magnetic setting, 50 Hz, 415 Volts, 35 KA -05 Nos. Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. Note :- (i) Location-near Kabul Line (ii) Location cannot be changed without permission of GE, approval of GE is mandatory for any changing in location.
Outgoing :- (i) MCCB 4 pole, 200 Amps, with Adjustable Thermo and Adjustable Magnetic setting, 50 Hz, 415 Volts, 36 KA -2 Nos. (ii) 3 Phase 4 Wire Electronic Trivector Meter - 1 No Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. Note :- (i) Location -near Syndicate Bank (ii) Location cannot be changed without permission of GE, approval of GE is mandatory for any changing in location.
Supply & fixing in replacement of Air circuit breaker 4 pole 1000 Amps 50 KA with Microprocessor release manual drawout Adjustable type including dismantling & taking out old unserviceable ACB from panels & fabrication works to BUS bar for proper fitting
Supply & fixing in replacement of Air circuit breaker 4 pole 800 Amps 50 KA withwith Microprocessor release manual drawout Adjustable type including dismantling & taking out old unserviceable ACB from panels & fabrication works to BUS bar for proper fitting . Note for item No-09 & 10:- The above quoted rate is included for additional for fixing of new ACBs if required
S&F (in replacement) change over switch 100 Amps ON load (side handle) in sheet enclosure four pole to be fixed on wall with FI 32X6mm, nuts, bolts, washers etc. complete with all electric connection complete all as specified and directed.
S&F (in replacement) change over switch 200 Amps ON load (side handle) in sheet enclosure four pole to be fixed on wall with FI 32X6mm, nuts, bolts, washers etc. complete with all electric connection complete all as specified and directed.
S&F (in replacement) change over switch 400 Amps ON load (side handle) in sheet enclosure four pole to be fixed on wall with FI 32X6mm, nuts, bolts, washers etc. complete with all electric connection complete all as specified and directed.
S&F in replacement of UNSV MCCBs of capacity 630 Amps, TP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as directed
Description all as per ser item No 14 above, but rating of MCCB 400 Amp, 36 KA
Description all as per ser item No 14 above, but rating of MCCB 250 Amp, 36 KA
Description all as per ser item No 14 above, but rating of MCCB 200 Amp, 25 KA
Description all as per ser item No 14 above, but rating of MCCB 160 Amp, 25 KA
Description all as per ser item No 14 above, but rating of MCCB 125 Amp, 25 KA
Description all as per ser item No 14 above but rating of MCCB 100 Amp,25KA
Description all as per ser item No 14 above but rating of MCCB 63 Amp, 25 KA
S&F in replacement of UNSV MCCBs of capacity 630 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as directed
Description all as per ser item No 22 above but rating of MCCB 400 Amp, 36 KA
Description all as per ser item No 22 above but rating of MCCB 320 Amp, 36 KA
Description all as per ser item No 22 above but rating of MCCB 250 Amp, 36 KA
Description all as per ser item No 22 above but rating of MCCB 200 Amp, 25 KA
Description all as per ser item No 22 above but rating of MCCB 160 Amp, 25 KA
Description all as per ser item No 22 above but rating of MCCB 125 Amp, 25 KA
Description all as per ser item No 22 above but rating of MCCB 100 Amp, 25 KA
Description all as per ser item No 22 above but rating of MCCB 63 Amp, 25 KA Note for item No. 14 to 30:- All the MCCBs should be connected to the bus bar directly through expended links.
Material and labour in replacement for ATS 4 pole of capacity 200 Amps complete including fixing arrangement i.e suitable size of MS flat, nuts, bolts, washer, fixing of LT cables of any size with suitable size of lugs all as specified and directed.
Material and labour in replacement for ATS 4 pole of capacity 400 Amps complete including fixing arrangement i.e suitable size of MS flat, nuts, bolts, washer, fixing of LT cables of any size with suitable size of lugs all as specified and directed.
S&F in replacement fabricated steel enclosure made out of 18 SWG Sheet suitable for mounting of MCCBs including MCCB of capacity 200 Amps including clamp made of 40x5mm FI,Nuts,bolts,washers complete all as specified and directed.
Supply and fixing On load change over switch in replacement of capacity 200 Amps, four pole, 415 volts, AC, 50 Hz.
Supply and fixing On load change over switch in replacement of capacity 400 Amps, four pole, 415 volts, AC, 50 Hz.
Material and Labour for disconnecting burnt end or portion of cable removing the cable from loop including necessary excavation & earth work in soft/loose soil relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals including fixing of new lugs for 50 Sqmm 3½ / 4 to 400 Sqmm of LT cable to pole / main switch including taping of XLPE cables complete all as specified and directed.
Material and labour in replacement of Voltmeter 0-500 V digital type as per existing size complete all as per specified and directed.
Material and labour in replacement of Ammeter 0-400/800 Amp digital type per existing size complete all as per specified and directed
Supply and fixing in replacement of indicator lamp for RYB phases complete all as specified and directed.
Supply and fixing in replacement LT current transformer having ratio 1000/5 Amp , 15 VA, Class 0.5. Complete all as specified and directed by Engr-in-Charge
All as per Srl item No.41 herein before but CT ratio 800/5 Amp
All as per Srl item No.41 herein before but CT ratio 400/5 Amp
All as per Srl item No.41 herein before but CT ratio 250/5 Amp
Supplying and fixing in replacement Mild steel sliding door bolts 200 mm long ,plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate
Supply and fixing in replacement of cable gland for LT panel/feeder pilar up to 50 Sqmm cable complete all as specified and directed.
Supply and fixing in replacement of cable gland for LT panel/feeder pilar for 70 sqmm cable to 240 Sqmm cable complete all as specified and directed.
Supply and fixing in replacement of cable gland for LT panel for 300 sqmm cable to 400 Sqmm cable complete all as specified and directed.
Earthing complete in replacement with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in soft/loose soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in soft/loose Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply and fixing in replacement of galvanised iron strip 32 X 6 mm for additional earthing lead beyond 7.5 meter.
Material and labour for painting of LT panel boards out door/in door of size up to 3.00 Sqm floor mounted installed at different locations including preparation of exposed surface by removing old paint from the body, cleaning the surface with thinner and applying two coats of synthetic enamelled smoke grey paint complete all as specified and directed.
Material and labour for painting of LT panel boards out door/in door of size above 3.00 Sqmm floor mounted installed at different locations including preparation of exposed surface by removing old paint from the body, cleaning the surface with thinner and applying two coats of synthetic enamelled smoke grey paint complete all as specified and directed.
M & L for cutting and removing grass, vegetation bushes etc from surrounding of installation/LT Panel/Four Pole structure/Sub Stations and removing all rubbish to a distance not exceeding 50 m as directed.
Material and labour in replacement for CRCA MS sheet of thickness 3.15 mm powder coated finish over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer with apran for cable entry closing locking arrangement including all fixing acessories i.e. suitable size of hinge, nuts, bolts, washers, cutting and welding works etc complete all as specified and directed.
Supply and fixing in replacement of Automatic Light Timer switch with Natural switch Cat No. SWADEEP-02EC12KW3P, infra ray sensor with pre sawn switching off timer, 4-8 hrs, of Maximum load capacity of 4KW per phase. Degree of protection conforms to IP 65 Make- Nature Switch/Schneider/Seimens complete all as specified and directed.
Supply only CRC liquid solution for electrical use, pressure packed in bottle.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge
Vijay Electricals
Rajindera Enterprises
MV Engineers And Contractors
M/s Adhikari construction co.
AVON ELECTRICALS
Buddham Builders
Ridhi engineers and builders
DS CONSTRUCTION
M/s Birja Nand
M/s ELECTROSHINE ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .