Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.8 CrAccepted-AOC G 20 225 SEC 7 ROHINI DELHI 85 | NORTH EAST | DELHI | 110053 | ₹4.8 Cr Quoted ₹4.7 Cr | 1 | Accepted-AOC L-1 |
| 2 | 2₹8.3 Cr+₹3.7 Cr (79.1%)Rejected-Finance 2367 E BAWANA ROAD NARELA DELHI 40 | ₹8.3 Cr+₹3.7 Cr (79.1%) | 2 | Rejected-Finance L2 |
| 3 | 3₹8.5 Cr+₹3.9 Cr (83.3%)Rejected-Finance N A | NA | NA | 121004 | ₹8.5 Cr+₹3.9 Cr (83.3%) | 3 | Rejected-Finance L3 |
| 4 | 4₹8.6 Cr+₹3.9 Cr (83.4%)Rejected-Finance N A | NA | NA | 121004 | ₹8.6 Cr+₹3.9 Cr (83.4%) | 4 | Rejected-Finance L4 |
| 5 | 5₹8.6 Cr+₹4.0 Cr (84.7%)Rejected-Finance N A | NA | NA | 121004 | ₹8.6 Cr+₹4.0 Cr (84.7%) | 5 | Rejected-Finance L5 |
Tender Value
₹6.1 Cr
EMD Value
₹13.5 L
Closing Date
11 Dec 2023, 3:00 pmClosed
EE(Pr.)NGZ
Room NO. 207, Zonal Office Building, Najafgarh
Construction of 6 class rooms, one store room, one computer lab, one office room, one library room, one staff room, one hall (equivalent to 3 rooms) and two toilet blocks in MC Pry. School Ghumanhera (Boys) in NGZ
2023_MCD_176190_1
EE(Pr)NGZ/Plan/2023-24/02/01
Open Tender
Civil Works
Works
365 days
Najafgarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
₹13.5 L
21 Mar 2024
30 Nov 2023
11 Dec 2023
1 Dec 2023
11 Dec 2023
1 Dec 2023
Amount
Part B
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, modular switch,modular plate,suitable GI Box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 A,36KA,FPMCCB
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp switch
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 2 Module (75mm X75mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface / recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connections etc. as required.
Supplying and fixing call bell/buzzer suitable for single phase, 230 V complete as required.
Wiring for light/power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduite along with 1 no 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required..2x2.5 sq.mm +1x2.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required.4x2.5 sq.mm +2x2.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required.2x6 sq.mm +1x6 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required. 2x 4 sq. mm + 1 x 4 sq. mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required.4 x 4 sq. mm + 2 x 4 sq. mm earth wire
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening including makinggood the damage,connection,testing,commissioning etc.as required.(a) Up to 450 mm sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a)Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(b)Double Pole
Modular blanking plate
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. Up to 35 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as required. Up to 35 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq.mm ( Clamped with 1 mm thick saddle )
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
S/F installation of cubical panel board 16 SWG sheet M.S depth 30 cm to 60 cm with A1. bus bar and interconnection suitable for switch gears i/c and making foundation etc as required
Supply of XLPE insulated and PVC sheathed Al. conductor armoured cable 1.1 KV grade confirming to IS 7098 as required.( a ) 2x10 sq.mm
Supply of 15'' (380mm)sweep 1400 rpm exhaust fan heavy duty complete with shutters blades etc as reqd
S.I.T.C LED tube type luminaire 20 watt rating complete with extruted alluminium batten prewired with high efficiency LED with the following specifications.(A) Total system wattage 20 watt+/- 5% ,(B) Luminous efficiency >= 95 Lumens/watt, © Power factor >= 0.95
S.I.T.Cof 150 W LED flood light luminiare fitted with lens made of pressure die cast aluminium housing &toughened glass cover complete with the following specification as required (b)Total system voltage =150 watt +/-5% (c) Luminiare Efficiency =100 Lm/w (d) Power Factor >=0.95( e) Protection Class - IP -66
P & F of Hot Press Sheet Moulded Compound (SMC),fire retardant (Temp. resistanceup to 200 deg.C),IP-55 weatherproof pole box of inner dimension 200 mmx160 mmx98 mm(NS)complete with suitable arrangement for fixing of 2 nos.of 6 to 32 amp single pole MCB &63 A double pole isolator(MCB/Isolator exluded )with neutral link duly shorting on DIN channelwith 2 nos.of clamps with SS back plate of suitable size with danger monogram & SDMC property printed on the cover etc. as required
Supply of 1200mm sweep 50 Watt , Energy Saver ISI Marked BEE 5 Star rating AC Ceiling fan suitable for 230 V, 50 Hz AC supply without regulator with blades,downrod etc. Complete as required
Supply,installation,testing & commissioning of single / three phase monoblock pump set complete with all accessories workable on 240/415 volts,50 Hz AC supply.(a) 1 HP (0.75 KW) Single phase pump set,head from 12-30 mtrmtr,suction and delivery 25X25 mm
Providing & fixing circular/hexagonal cast iron of MS sheet box for ceiling fan clamp of internal dia 140mm,73 mm hight,top lid of 1.5 mm thick MS sheet with its top surface hacked for proper bonding, top lid shall be screwed in to the cast iron /MS sheet box by means of 3.3 mm dia round headed screws,one lock at the corners, clamp shall be made of 12 mm dia MD bar bent to shape as per standard drawing.
S/I/T/C of 2MP fixed lens Bullet IP Camera with following specifications:- Image Sensor: 1/3 2MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better ** Shutter Speed:1/3 – 1/100,000 s Frame Rate:1-25/30 fps or better ** Lens: 2.8 mm fixed. Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (1920x1080) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 30m Operating Temperature: -30 to 50 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL.
S/I/T/C of 2MP DOME IP Camera with following specifications:- Image Sensor: 1/3 2MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better ** Shutter Speed:1/3 – 1/100,000 s Frame Rate:1-25 fps or better ** Lens: 2.8 Fixed Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (1920x1080) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 25m Operating Temperature: -20 to 55 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL.
S/I/T/C of 4MP varifocal lens Bullet IP Camera with following specifications:- Image Sensor: 1/3 4MP CMOS Minimum Illumination: 0..05 lux color, 0 lux with IR or better ** Shutter Speed:1/3 – 1/100,000 s Frame Rate:20 fps or better ** Lens: 3.6 to 10mm Varifocal lens Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (2650x1440) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 30m Operating Temperature: -20 to 55 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL.
S/I/T/C of 32 channel NVR with the following specifications: Camera resolution:upto8MP Interface: 1 HDMI, 1VGA minimum Compression :H.265or better** Network Throughput :200Mbps or better** USB Port: 2 USB port (USB2.0)minimum Hard disk interface: 2 SATA port suitable for 6TB each Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS Operating temp: -10 to 55 deg Cent Safety standard: UL
SITC of 6 TB surveillance HDD
SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch
SITC of On-line UPS with inbuilt isolation transformer suitable for single phase AC input and single phase AC output, Floor mounted type, indicative power backup time of 60 mins through SMF batteries. 3KVA
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supply Installation testing Commissioning of following wall/ standing M.S powder coated rack with glass front door, fan, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U
S/I/T/C of LED Monitor full HD complying to with following specifications: Resolution : Full HD : 1920 x 1080 or better Backlight : LED Brightness : 400 NITS min. Video I/P port a) Min. 02 No HDMI 1920X1080. b)Min 01 No VGA Contrast : 1200 : 1 or better Power supply : 230v + / - 10%, 50 Hz installation at site with connections and along with all accessories of 42 INCHES sizes etc. comp as required with min 3 year onsite warranty.
SITC IP65 box for fixing on pole or wall with suitable arrangement for PoE switch and modular switch socket complete as required.
Supply, fabrication and installation of MS iron 600 mm long angle of 50x50x5 mm dimension,with suitable nut bolts for wall support to stand camera .
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Bidder Name
Amount
m/s naresh rai(GSTN-NA)
SANJEEV ASSOCIATES(GSTN-NA)
N K Construction Company(GSTN-NA)
M/s Aggarwal Const. Co.(GSTN-NA)
R K BUILDERS(GSTN-NA)
J.S. CONST. CO.(GSTN-NA)
Manoharlal(GSTN-NA)
M/s Surender Kishan Gupta & Co(GSTN-NA)
Description of Work / Item(s)
Part C
Dismantling of existing old structure-Reserve price
SANJEEV ASSOCIATES
M/s Aggarwal Const. Co.
Manoharlal
J.S. CONST. CO.
M/s Surender Kishan Gupta & Co
R K BUILDERS
N K Construction Company
SANJEEV ASSOCIATES
J.S. CONST. CO.
M/s Aggarwal Const. Co.
Manoharlal
N K Construction Company
R K BUILDERS
M/s Surender Kishan Gupta & Co
SANJEEV ASSOCIATES
M/s Surender Kishan Gupta & Co
M/s Aggarwal Const. Co.
m/s naresh rai
N K Construction Company
J.S. CONST. CO.
R K BUILDERS
stage.html
html • 0.06 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_192883.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .