| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹42.1 L+₹1.9 L (4.60%)Rejected-Finance 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹42.5 L+₹2.2 L (5.50%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹45.3 L+₹5.0 L (12.5%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
12 Jun 2023, 6:00 pmClosed
MAJ SRINATH PL
GE I Kanpur Cariappa Road Cantt Kanpur 208004
PROVN OF 85 GEYSERS AND 63 KVA TRANSFORMERS IN CERTAIN UNITS UNDER GE (I) KANPUR CANTT.
2023_MES_596256_1
GE(I)/KAN/T-23 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE(I) KANPUR
₹58,000
Yes
12 Sept 2023
17 May 2023
17 Jun 2023
17 May 2023
12 Jun 2023
30 May 2023
Amount
Supply and fixing electric water heater, stoarge type made of ultra thick super cold rolled steel plates, feroglass dry powder coat-ing technology inner tank and heating element heavy duty mag-nesium anode rod with steel core to protect enamelled tank from rust and corrosion upto 2 kW Capacity, 230 Volt, 1 Phase AC, 50 Hz, 25 Ltrs, BEE 5 Star, Energy saving high density PUF insulation, glass coated heating performance and resistance to oxidation and carbonation at high tempratures rated complete with all accessories such as safety valve, thermostat, NRV, connection piece and writing MES no. in black synthetic enemael paint/engraving tool etc complete all as specified & directed.
M & L for sub main wiring with two single core of 4 sqmm copper conductor FRLS, PVC insulated and unsheathed multi-stranded cable including PVC conduit medium grade of 25 mm dia, concealed in / surface on walls for sub main connection and 1.5 sqmm FRLS, PVC insulated and unsheathed multi-stranded green colour copper conductor cable as an earth wire to common earth and connected to earth dolly complete all as specified and directed
S&F Stainless steel heavy duty of suitable length for hot water supply with two nos nut adapter ISI marked complete all as specified and directed
Supply & fixing in replacement of angle valve chromium plated brass screwed down high pressure with crutch handle screwed both ends for GI pipe 15 mm dia bore with suitable accessories complete all as directed.
Supply & Laying, jointing and leakage testing GI tubing medium grade 15 mm Bore with all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches/floor/walls/roofs and making good the disturbed surface to match with existing surface as (PCC work in 1:2:4 using 20 mm graded stone aggregate/ plastering in CM 1:4 and applying finishing coat of existing treatment) complete all as specified and as directed at site
S&F Single pole neutral Enclosure with a two pin and earth plug and socket complete withj one single pole MCB 20 Amp complete all as specified & directed.
S & F VTPN distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link, confirming to complete with one MCCB 3 pole 415 Volts 100 Amps, 4 pole rating with rupturing cap 26 KA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed.
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
M&L for MCB single pole 240 volts 6 to 25 amps, with rupturing capacity 10 KA using thimbles of required size.
M&L MCB single pole & neutral 240 volts 30 to 63 amps,with rupturing capacity 10 KA using thimbles of required size.
M&L for submain wiring with three single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 2.5 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 1.5 Sqmm as earth lead in & including concealed PVC conduit medium grade 32mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces and paiting same as existing to match with existing specification of walls all as required at site or directed by Engr-in- charge.
M&L for RCCB ,double pole,single phase 240 volts , rated current 25 amp, sensitivity 30 mA, 10 kA complete using thimbles of required size complete as per directed by Enginer-in-charge.Make: Legrand/Havells/Schneider
S&F Bib tap standard of casted brass with chromium plated quarter turn spindle suitable for GI pipe 15 mm dia with all accessories as per directed.
Supply and laying in trenches XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 70 Sqmm 3.5 core complete.Make of cable Havells/kalinga/Polycab.
Supply, installing, testing and commissioning of out door type, floor mounted step down transformer, 11 kV/6.6 kV/433 Volts (at no load) AC 3 phase 50 Hz, 63 kVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural-Air Natural (ON AN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at +5% to -10%in steps of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 35 degree celsius in oil and 40 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius. Perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS 1180 (Part-I) : 2014, Energy Efficient Level -II as per latest amendment IS-1180(Pt-I) and shall comprise of the following :- NOTE: 1. One cable box on HT side (primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception 95 sqmm x 3 core, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete all as specified and directed. 2. One cable box on LT side (Secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable size/rating of cable complete. 3. Oil conservator with filter type drain valve and oil level guage. 4. De-hydrating breather with first fill of dehydrating agent (silica gel). 5. Explosive vent, Thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs, Oil filling hole with cap / plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers 6. One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. 7. Two earthing terminals on tank cover to facilitate fixing of earth strip for earthing of body 8. Rating plate and terminal marking plate. 9. Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral. 10. First fill of new and unused transformer oil, IS-335 marked, filtered and tested upto 50 KV die-lectric strength at 2.5 mm air gap between testing electrodes. 11. Provn the angle iron channel for floor mounted outdoor type transfomer as per site requirement. 12. Providing adequate size and nos of channels, embeded in platform floor, for movement of transformer. 13. Unidirectional roller wheel. 14. Other accessories as per manufacturer design. 15. Offr for Factory inspection will be detailed by Accepting Offr.
Supplying, installation, testing & commissioning of outdoor 11 kV, extensible 630 Amps, 21kA IP54 Outdoor type SF6 gas insulated 630 Amp Copper busbar RMU comprising of manual 4 Load Break Switch . The LBS shall be enclosed in robotically welded minimum 2.5 mm thick non magnetic, non ferrite Stainless Steel tank filled with SF6 with IP class IP67 , leak rate less than 0.1% and HT tank tested for internal arc fault of 21kA upto 01-second as per latest IEC 62271-200. The unit shall have front/side/rear cable entry for ease of installation. Fault Passage Indicator in all LBS. The outer enclosure shall cover the full length of the switch gear, to ensure IP54 protection for full door covering of complete switchgear Cable bushings shall be site replaceable type for repair of RMU at site. (Inspection of RMU to be done at above manufacturer's factory) 1.Load break switch module - 4 Nos. 2-Manual operated 12 kV, 630A Load Break switch and Earthing Switch with making capacity. 3- “Live Cable” LED Indicators through Capacitor Voltage Dividers mounted on the bushings. 4-Earth fault passage indicator in incoming LBS. 5-Mechanical ON/OFF/EARTH Indication. 6-Cable boxes suitable for 1x3Cx120 sq mm XLPE Cable with right angle Cable Termination Protectors, situated towards side of RMU. 7-Cable Door should be arc proof and interlocked with respective Earthing Switches. For safety of operator it should not be possible to open the cable Door unless the earth Switch is ON. 8- Cable box should be arc proof with bolted door and interlocked with respective earthing switches. (i) The contractor will produce drawing of load break switch (LBS) for according approval before the ordering of material. 9. Offr for Factory inspection will be detailed by Accepting Offr.
M & L for Construction of Platform for installatiom of Transformer of size 3mX2.5mX1.2m with brick work in cement mortar 1:6 earth filling,300 mm thick PCC 1:6:10 type E2, 100 mm thick PCC 1:2:4 type B1 using 20 mm crushed stone aggregate in florring , including XPM fencing (weight not less than 4 kg/sqm) with support of angle iron frame 50 x 50 x 6 mm at four corners with gate with locking arrangements and all steel surfacces well treated with two coats of synethic enamel paint over a coat of red oxide primer complete all as per Drg in CA No CELZ/Kan-03/19-20 of CELZ
M & L for LT panel, Installation, commissioning and testing of new LT panel cubical type suitable for outdoor installation factory made CPRI approved of suitable size,dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron frame of siuitable size fixed on RCC/PCC block fixed with grounded bolts & nuts and washers including rating copper bus bar not less than 40X3 mm suitable for 250 Amps for 3 phase 4 wire mounted on epoxy based post insulators with suitable size of CTs,LED indicator lamp set type RYB (indicator lamps should display colour of phase as well as phase volatge complete) of make AE/Legrand/L&T, complete internal wiring with suitable size of copper conductor PVC insulated and sheathed cable front and rear openable double door with locking arrangement, angle iron frame made out from suitable size and making good all disturbed surfaces of floor/wall using RCC/PCC work as required at site complete all as required at site or directed. Makes : As approved by CELZ Note: All MCCBs should have adjustble thermal and fixed magnetic setting and Ics =100% Icu INCOMMER (i) MCCB 3 Phase, 4 Pole 160 Amps,35/36kA rupturing cap,415 volts 50 Hz AC supply - 01 Nos (ii) Digital VIF meter-01 Nos Make : ABB/L&T/AE (iii) Phase indicating lamp RYB with indicating voltage in digital LED format ( set of three) - 01 Set OUTGOING (i) MCCB 3 Phase, 4 Pole,100 Amps,25 kA,415 volts 50 HZ AC supply - 01 Nos (ii) MCCB 3 Phase, 4 Pole,63 Amps,25 kA,415 volts 50 HZ AC supply - 02 Nos
Supply and fix cable jointing kit for 11 kV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 Sqmm complete all as specified
M & L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 25 x 4mm thick for earthing lead fixed by means of nuts,bolt,washers etc.of copper / brass connected to earth test point complete all as specified in electrical plate NO 3 of SSR 1996 part 1 ,including necessary excavation and earth work in any strata of soil,GI water pipe with 20mm dia.funnel &wire mesh PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- All the joints shall be made with welding to get proper conductivity.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded,galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm.
Supply and laying in trenches or fixing to wall/pole or passing through pipe in replacement of XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 50 Sqmm 3.5 core complete including taking out old unsv cable of any type,make & cap.Make of cable Havells/Grandlay/kalinga/Polycab. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
S & F of Distribution board iron clad, double door with IP-43 ,IK-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, complete with one MCCB 3 pole 415 Volts 125 Amps rating with rupturing cap 16 kA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface and complete all as specified and directed.
Dismantling unserviceable insulators any type and taking down ACSR conductor, incl GI wire for neutral any size from HT/LT over head lines complete and remove from site all as specified and as directed by Engineer in charge.
Dismantling unsv insulators of any type complete and remove from site all as specified and as directed by Engineer in charge.
Dismantling unsv cross-arms of M.S. channel or angle sections etc.and remove from site complete all as specified and as directed by Engineer in charge. .
Dismantling unserviceable stay assembly complete and remove from site all as specified and as directed by Engineer in charge.
Dismantling unserviceable steel/PCC LT poles of any type complete and remove from site all as specified and directed by Engineer in charge.
Supply, erecting and installation of steel tubular, swaged, pole of overall length 9 meter having maximum tensile strength 42 Kgf/mm2 of type 410 SP-31 conforming to IS-2713-1980, single swan neck made out of 50 mm dia MS pipe 1.5 mtr long to be jointed on top of LT pole incl fabrication work for fixing street light. A through hole of 14 mm dia shall be provided at height of 2.5 mtr from base plate for inserting 2 core cable from junction box to top of the pole and top portion shall be fabricated for fixing street light fittings including earth work complete with cast iron base plate, having suitable dia of hole through the pole with nuts & bolts for earthing arrangement, bottom portion of tubular steel pole having 165.10 mm outer dia in 5 meter length, 4.5 mm wall thickness, middle portion having 139.70 mm outer dia in 2 metre length 4.5 mm wall thickness and top portion having 114.30 mm outer dia in 2 meter length, 3.65 mm wall thickness of pole wall, respectively, bottom MS square plate duly painted with two coat of black bituminous paint throughout, internally and externally up to planting depth and painting remaining portion of pole with two coats of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making / pasting three nos circular strips each of 100 mm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking / stencil writing of pole numbers with black paint including necessary excavation & earth work, removing excavated soil from site complete all as specified & directed. Note :- Necessary Excavation and earth work, PCC Work for foundation / erection of pole assembly will be measured & paid separately.
M & L for painting of steel pole (swan neck type or straight type) up to 9 mtr height with cross arms, clamp,bracket of any length and shape for LT overhead line / for street light with two coat of aluminium paint after scraping out old paint, cleaning and existing surface rust free, preparation of the existing surface, including marking pole numbers in a 20 cm dia yellow circle with number writting with black syenthic paint & painting strips in alternate from bottom to top with three strips of black syenthatic paint & two strips of yellow fluorescent paint (up to 1.5 mtr height) through out the circumference of pole (width of each strip shall be of 30 cm), complete all as specified and directed.
S & F street light bracket made out of GI tubing, light grade, 25/32/40mm bore, 1000mm long, bent to shape at 120 degree, fixed on pole by providing two sets of MS clamp made up of flat iron 40 x 6mm including bolts, nuts and washer of suitable size including painting the bracket & clamp with two coats of aluminium paint over a coat of primer complete all as specified and directed.
Supply, fixing, testing and comissioning of automatic street light switch of capacity 5-8 kW in three phase using nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals enclosed in pole / wall mounted enclosure Make : Hensel/GE confirming to IP66 enclosure box ,rust proof, electric shock proof, termite proof , including mounting arrangement with suitable size of FI clamps 02 Nos with complete acessories as under including taking down old street light switch complete all as specified and directed. Make : Healer Enterprises model : swadeep -66-5kW3P or technocommertially equivalent in Bajaj/Hensel (i) Contactor rating (AC3) three phase, 160amp per phase Amp : [Make : BCH/L&T/Schneider] (ii) MCB 32 Amps per phase ,10 KA, 240 volts: [Make : Schinder/ Legrand/ L&T] (iii) NATURESWITCH-01 [Make: HEALER (Model No. SWADEEP - 02EC8kW1P) or equivalent to Bajaj/Hensal]
S&F weatherproof junction box of size not less than 240 x 130 x 110 mm outdoor type made out of thermo polycarbonat to accmmodated 04 Nos aluminium bus bar of size 25x6 mm rating 200 Amps and MCB SP 20 Amps IP-55 with hinged door and triangular locks water proof, shocked proof, rust proof, corrosion free, acid resistance/fire retardent and self extinguishing UV resistance complete fixed on pole with flat iron clamps of size 25 x 3mm, nuts, bolts, washers etc., including two coats of synthetic enamel paint over a coat of redoxide zinc chrome primer on iron/steel parts complete incl taking down old one all as specified and as directed. Make: Sintex/ Hansel/Hager
Supply & fix cable PVC insulated flexible aluminium conductor cable of size 2.5 Sqmm three core cut to pieces all as required for connection with proper thimbles, drawn in existing GI/PVC conduit pipe fixed on wal/pole, on steel pole and bracket from junction box to street light all as directed.(Rates of 20 mm PVC condiut pipe and AL/MS wire to fasten the Conduit pipe with poles are included) Make of Cable : Havells/Plaza/Anchor
S&F of High power LED street light 120 watt IP 66 with minimum 100 lm/W, Energy saving & environmental friendly long life Versatile pressure die-cast aluminium roadway luminaire with high power LEDs as light source and electronic driver fixed on pole/wall incl electric connections complete all as spfd. Make : Havells/ Wipro/ Philips
S&F of High power LED street light 45 watt IP 66 with minimum 100 lm/W,Energy saving & environmental friendly long life Versatile pressure die-cast aluminium roadway luminaire with high power LEDs as light source and electronic driver fixed on pole/wall incl electric connections complete all as spfd. Make : Havells/ Wipro/ Philips
M & L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to galvanised earth lead wire 4.0mm dia by means of nuts,bolt,washers etc.of copper / brass connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,GI water pipe with 20mm dia.funnel &wire mesh PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- All the joints shall be made with welding to get proper conductivity.
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, foundation filling of poles or stays and for rerouting of cables.
All as per item No-39 but depth exc 1.5 mtr but not exc 3.00 mtr and complete all as specified and directed.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable
M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
M&L for pre cast cement concrete ( 1:4:8) type D2 using 40mm graded stone aggregate for oundation filling of poles as mass concrete.
M&L for pre cast cement concrete ( 1:3:6) type D2 using 40mm graded stone aggregate for foundation filling of stays.
M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable bore for cable protection pipe upto 80 mm bore complete all as specified and as directed. Note: Depth of bore shall not be more than 1 Mtr from original ground level.
Supply and laying in trenches or fixing to wall/pole or passing through pipe PVC insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core.Make of cable: Havells/ Plaza/ Polycab/ Finolex. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
All as per srl item No-48 but cable of size 35 Sqmm 3.5 core and complete all as specified and directed.
All as per srl item No-48 but cable of size 70 Sqmm 3.5 core and complete all as specified and directed.
Supply and fix in replecement bus bar chambers 300 mm long iron clad with 4 Nos 200 Amp rated copper strips complete fixed on Suitable size of Angle iron and with PCC and making good the disturbed wall surfaces all as a required at site or directed.
Point wiring for one 05 Amps socket on indipendent board controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FR with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 25mm dia with all fittings (ISI Marked) controlled by one switch including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
M&L for switch piano flush button single pole one way 5/6 amps 240 volts.
M&L for socket 5 amps 5 pin flush type, 230 volts.
All as per srl item No-2 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl PVC conduit.
M&L for switch piano flush button single pole one way 15/16 amps 230 Volts.
Supply, installation, testing, commissioning of desert cooler of capacity 5000 CFM made out of 0.8 mm thick galvanized steel sheet with complete fully exhaust fan 450 mm sweep, 1400 rpm motor of copper winding and suitable capacity submersible pump and wood wool fitted in frame made from size MS Wire mesh net of 14swg dia fitted on both sides for supporting wood wool cabinet size not less than 92cmx74cmx66cm water tank of capacity 75Liters made of GI sheet ,1000 watts speed control electronic regulator, suitable size connection cable 3 core with copper conductor with moulded plug top, fan blade and all fixing accessories complete all as specified and as directed Note:- All electrical equipments shall be of ISI Marks.
M&L for fixing MS angle iron support for fixing of desert cooler incl nut, bolt, painting and grounting of angle iron in wall after that making good all disturbed surfaces of wall including PCC 1:2:4 type B-1 and painting as exist all as spdf and directed.
Supply & Fix exhaust Fan steel body AC single phase 300 mm sweep with blades ,and frame and louvers complete all as specified and directed.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage 80 ltr and nominal cooling capacity of 40 ltr complete all as specified & directed.
Supply & Fixed Gun metal Gate valve with iron wheel head conforming to IS : 778/ 1984, Class-1, Screwed both end as per IS: 554 Parallel, ISI marked including taking out the worn out/ old gate valve any typecomplete all as specified and directed suitable for following bore of pipes
M/s Anupam Construction Co.
santosh electronics
SUSHMANAND ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .