Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹579.2 CrAccepted-AOC | ₹579.2 Cr | 1 | Accepted-AOC L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical Does not satisfy all eligible criteria |
| Sl No | Description | Qty | Unit | Nyati Engineers And Consultants PVT Ltd L1 |
|---|---|---|---|---|
| 1.00 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means | 17,485.58 | Cum | 233 ₹40.7 L |
| 2.00 | Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means | 1,942.84 | Cum | 255 ₹5.0 L |
| 3.00 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum,including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means | 1,924.26 | Cum | 290 ₹5.6 L |
| 4.00 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means | 15,394.1 | Cum | 319 ₹49.1 L |
| 5.00 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means | 1,924.26 | Cum | 589 ₹11.3 L |
| 6.00 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 3.0 to 4.50m.) By Mechanical Means | 8,920.05 | Cum | 380 ₹33.9 L |
| 7.00 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 3.00 m To 4.50 m.) By Mechanical Means | 8,920.05 | Cum | 701 ₹62.5 L |
| 8.00 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 4.50 to 6.00m.) By Mechanical Means | 3,677.1 | Cum | 411 ₹15.1 L |
| 9.00 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 4.50 m To 6.00 m.) By Mechanical Means | 8,579.91 | Cum | 758 ₹65.0 L |
| 10.00 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. | 19,530.78 | sqm | 120 ₹23.4 L |
Tender Value
₹551.6 Cr
EMD Value
₹5.5 Cr
Closing Date
26 Dec 2025, 5:00 pmClosed
CE MSIDC Mumbai
13th Floor BAkhtawar chember Nariman point Nashik
Construction of New Surgical Building at Government Medical College and Hospital , Chhatrapati Sambhajinagar
2025_MSIDC_1259098_1
10
Open Tender
Civil Works
1095 days
Chh Sambhaji Nagar
Please refer Tender documents.
7 documents required · 7 mandatory
₹35,400
Yes
₹5.5 Cr
Yes
CE MSIDC Mumbai
22 Apr 2026
13 Dec 2025
29 Dec 2025
13 Dec 2025
26 Dec 2025
13 Dec 2025
17 Dec 2025
Amount
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum,including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 3.0 to 4.50m.) By Mechanical Means
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 3.00 m To 4.50 m.) By Mechanical Means
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 4.50 to 6.00m.) By Mechanical Means
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 4.50 m To 6.00 m.) By Mechanical Means
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. Complete.
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. Complete.
Disposing of Unwanted/Un Servicable all kind of Material away from Site as Directed by Engineer incharge lead upto 10 Km
Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (To be executed with prior approval of Superintending Engineer)
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Retaining wall in Basement of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite/ quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mixcement concrete M-40 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap / granite/gneiss / quartzite metal for R.C.C. fins of required thickness in position as shown on the drawings or as directed by Engineer-in-charge including steel centering, plywood / steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete.
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) with 2 bars horizontal of 6 mm dia at every 3 layers of course
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it’s components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). Floor Joint of 100 mm gap
Providing and fixing of expansion/ seismic joint system of approved make related with wall joint (internal/External wall to wall/ ceiling to ceiling/ wall to corner/ any angle) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminium base members, self aligning/ centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an expansion joints system suitable for vertical wall to wall/ wall or ceiling at corner/ ceiling application, with no slipping down tendency amongst the components of the joint system. The joint system shall utilize light weight aluminium profiles exhibiting minimal exposed aluminium surfaces mechanically snap locking the multicellular to facilitate movement. No screws shall be visible on centre plate (hidden fasteners). The centre plate can be individually designed to match the adjacent surface and can be printed in same adjacent wall texture. Expansion joint system shall be with all mandatory requirement as per the manufactures design and as approved by Engineer-in-charge. (Material shall conform to ASTM 6063). Rate shall be inclusive of edge preparation, moisture barrier, polyester powder coating (Minimum 50 micron) on aluminium of approved shade and make if required. Expansion joint system shall be as approved for all floor all level including scaffolding etc complete. Internal Wall/ ceiling Joint upto 100 mm gap
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-in-charge. The joints shall be of extruded aluminium base members with, self aligning and self centering arrangement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminium base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). Roof Joint upto 100 mm gap
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm per coat
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc For horizontal surface one coat @1.10 kg per sqm.
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete.
Providing and applying Two coats of wall care Putty on Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete.
Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete.
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.
Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.
Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc.complete.
Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, moulding edges, polishing,cleaning complete. b) Granite
Providing 25 mm to 30 mm thick partition of polished black kadappa stone slab ofapproved quality including giving required size and shape etc. Fixing in cement mortar 1:3 curing and cement etc. complete. a) One side polish for Parking Area, External Gallary etc
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish
Providing and laying Heavy Duty vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete
Providing and laying Heavy Duty vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc.complete.
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurrycleaning curing etc. complete.
Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour to new plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete.
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
Providing and applying one coat of seal cement primer of approved manufacture and shed including scaffolding preparing the surface by cleaning dirt and other foreign matters, scrapping if necessary including scaffolding etc. complete.
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in Two coat including scaffolding, preparing the surfaces. (excluding the primer coat.)etc. complete.
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete
GI LOUVERS (13*75*13): Providing & Fixing of Oculus® 13*75*13mm louvers System manufactured by M/s. Oculus Building Products Pvt. Ltd., or Equivalent of approved exterior grade powder coating (Single side) RAL color consisting of 75mm wide x 0.5mm TCT louvers having 100mm (module) c/c with the clear gap of 250mm, length up to 4 meters. The Panel shall be clipped to a baked enameled GI Panel carrier of 20mm wide x 45mm deep x 0.5 mm thick in standard length of 3 meters. (Vertical Application)
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear)
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete
Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc. including welding grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts, etc. of the required size on the top of the floor of the side of waiste slab with suitable arrangement as per approval of engineer in charge (for payment purpose, only the weight of the stainless steel members shall be considered including fixing accessories such as nut bolts, fasteners etc.). 50mm dia. pipe, 1.5mm thickness and weight 1.92Kilogram/ r. metre
Providing and fixing 40mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate)
Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/ One Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.
Providing and fixing 90 cm x 60 cm Granite plate engraving 10 cm. Height letter, figures including painting the lefters/figures with approved colour and shade complete
Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (Heat Reflective Paint).
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.
Medium Height Partition @ 1800/1200HT TILE BASED PARTITION SYSTEM Tile based Aluminum / GI framing partition system of 1800/1200mm ht. made of 75mm thick aluminum / GI frames having two separate race-ways for laying electrical & computer wiring. The wire management shall be through to the race-way to be fitted at bottom of partition other immediately below of work top with hook on type raceway cover for easy access of wires. Frames to be joined by aluminum connectors with M6 x 16 pan-head machine screw and washer with aluminum post cover. Post cover snap on fashion to be connected on aluminum connector visible aluminium to be in anodized / powdercoated finish. The top exposed sides of the frame and posts should be covered with horizontal/ Vertical trim and caps made of Aluminum in anodized / powdercoated finish in order to enhance its look.Upper tiles on the partition to be in Soft Board or Marker or prelaminated partical board / Pre-Compressed Board/Compressed Board tile of 9mm. thk., prelaminated partical board lower tiles in laminate finish 9mm. thk. on both the sides .Size :- 1200/1800mm (H)
Providing and fixing 1.5 mm thick polyvenyl venyl chloride flooring including leveling the base with white cement including pasting with appropriate material cleaning the surface etc. complete
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
Wall Guard at bottom level Providing and fixing polyamide vinyl wall guard having vinyl snap on cover (lead free) and rubber spacer of 2mm thickness each to absorb the shocks and aluminum retainer of 2mm thickness that shall be fabricated from 6063-T5 aluminum. Dimensions to be of 100mm height x 20mm depth. The polyamide vinyl profile shall resist an impact of 30.2 ft-lbs/inch as per ASTM D-256-90b and shall not support fungal or bacterial growth. Polyamide Vinyl Snap on cover of 2mm thickness shall be extruded from chemical and stain resistant poly vinyl chloride with the addition of impact modifiers. The system shall also conform to class B1 fire rating, chemical and stain resistance. Rate shall be inclusive of all required accessories like corner piece etc complete
Wall Guard at upper level Providing and fixing handrail of having vinyl snapon cover (lead free) of 2mm thickness and aluminum retainer of 2mm thickness that shall be fabricated from 6063-T5 aluminum. Dimensions to be of 145mm height x 85mm width and 38 mm gripping diameter. The system shall resist an impact of 45.5 ft-lbs as per ASTM F-476-84. The polyamide vinyl shall not support fungal or bacterial growth. Polyamide Vinyl Snap on cover of .080" (2mm) thickness shall be extruded from chemical and stain resistant polyvinyl chloride with the addition of impact modifiers. The system shall also conform to class B1 fire rating, chemical and stain resistance.
Corner Guard (internal area) Providing and fixing corner guard having vinyl snap-on cover (lead free) of 2mm thickness and aluminum retainer of minimum 1.4mm thickness that shall be fabricated from 6063-T5 aluminum. Dimensions to be of 76mm x 76mm wings and 90 degrees angle. The polyamide vinyl profile shall resist an impact of 30.2 ft-lbs/inch as per ASTM D-256-90b and shall not support fungal or bacterial growth. Polyamide Vinyl Snap on cover of .080" (2mm) thickness shall be extruded from chemical and stain resistant polyvinyl chloride with the addition of impact modifiers. The system shall also conform to class B1 fire rating ,chemical and stain resistance.
Providing and laying in place 300mm x 300mm x 9.8mm vitrified tactile warning and directional tiles of the approved brand, make and colour inside the buildings at in all corridors and lobbies, level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer including zarri making wherever required and finishing including grouting the joints with white cement with matching pigments etc. up to the satisfaction of the engineer in charge complete.
Providing and laying in place 300mm x 300mm x 16mm cement tactile directional and warning tiles (for a person with visual impairment)of the approved brand and make and specified colour for outdoor floors such as footpath, courtyard, multimodals location etc. laid on 20mm thick base of cement mortar 1:4 (1 cement: 4 coarse sand) in all shapes and patterns including grouting the joints with white cement with matching pigments etc. complete as per direction of engineer in charge
Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 One Numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12mm thick panels shall be used for a roofing height of upto 15 mtrs.
Providing & Fixing of Luxalon Aluminium Aerofoil 200 Plain Fixed Louver manufactured by M/s.Hunter Douglas India Pvt.Ltd. or equivalent make of required length (above 2.0 meter)
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)
Providing and applying 2 Coats of high quality acrylic copolymer matt approved low VOC emulsion paint of approved shadethat gives smooth, flat and washable and durable finishing of approved make. Paint should have good flow levelling property with good colour retention and incan antibacterial property. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC acrylic copolymer based primer sealer that has incan antibacterial property. The work activity should cover all aspects of applying paints from surface preparation, filling to erecting and dismantling of scaffolding, finishing the surface etc as directed by Engineer in charge.
Structural Glazing Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Structural Glazing Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6 mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6 mm thick, spacer tube 12 mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6 mm thick substrate with reflective soft coating on face # 2, + 12 mm Airgap + 6 mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Providing and fixing vision panel made out of 5 mm thick toughen glass of any shape any size in all type of flush doors (for non fire rated door). Glass shall be fixed with superior class teak wood beading on both side the door of required size as shown in drawing and direction of Engineer-in-charge. Rate shall be inclusive of the cost of making opening in door, provision of glass, superior class teak wood beading both side, extra batten support required around periphery of opening, cost of PU polishing etc complete. Installed glass area shall be measured for payment without considering any wastage.
Solid Core Flush door Double leaf Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202– 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter
Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete.
Providing of 120 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at NationalTest House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). a) Door Frame: Supplying & Fixing frames for Fire resistant door shutters 1st classMalaysian Hardwood Frame densified (810 Kilogram/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 mm spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10mm x 4mm affixed in the slit of the Frame for fire and smoke sealing, etc. complete.
Providing of 120 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at NationalTest House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). b)Shutter : Supplying & Fixing of 55mm thick asbestos free criteria checked - fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance - FD 120 as per IS:3614 (part - II) comprising of 2x8mm Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in vaccum pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood, densified to 810 Kilogram/cum) frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128 Kilogram/cum), vermaculite mix faced with 3mm Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush- Type intumescent strip of size 10mmx4mm affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping.
c) Vision Panel: 2 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside the shutter structure with 10 mm inside the shutter on all sides with U- glazing. An additional insulated powdercoated 'Z' channel of 16 swg MS sheet to be fixed for reinforcement of the joints. (Any size 300x200,450x120,600x100mm)
Door Closure: (For 2 Hr fire Rated EN-3 Door Closure) Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors of different size (e.g size -EN-3 for leaf width upto 900mm) CE certified, marked & conforming to EN - 1154 of approved quality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnum etc.) fitted and fixed Complete as per direction &satisfaction of Engineer -in Charge including all taxes & incidental charges.
12"SS Handle: (For 2 Hr fire Rated 12"SS Handle) Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubularHandle with Grade 304, CE certified, marked & conforming to EN - 1154 of approvedquality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnumetc.)as per direction of Eingineer -in Charge fitted and fixed complete including all taxes& incidental charges.
Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening with 5 mm thick float glass etc. complete. a) With colour anodizing Note While arriving at the rate of item of item weight at 6.90 Kilogram/ One Square Metre is considered.
Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick andfor shutter plain glass panes 5 mm thick for top panels and 12mm thick both sidelaminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark, heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy dutyconcealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.
Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint)
Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -10 mm dia 200mm depth
Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -16 mm dia 320mm depth
Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -25mm dia 500mm depth
Providing and wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer-in-charge. Core cutting - Up to 52 mm dia.
Providing and wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer-in-charge. Core cutting - Beyond 52 mm dia. up to 102 mm dia.
Providing and wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer-in-charge. Core cutting - Beyond 102 mm dia. up to 202 mm dia.
Providing in position rigid PVC pipe sleeves of 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam before concreting. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Measurement shall be taken up to two decimal. (minimum 0.01 mt.). Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors/ all levels/ all heights. Location of sleeve shall be approved by Engineer-in-charge. PVC sleeve - 200 mm Diameter
Providing in position rigid PVC pipe sleeves of 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam before concreting. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Measurement shall be taken up to two decimal. (minimum 0.01 mt.). Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors/ all levels/ all heights. Location of sleeve shall be approved by Engineer-in-charge. PVC sleeve - 160 mm Diameter
Providing in position rigid PVC pipe sleeves of 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam before concreting. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Measurement shall be taken up to two decimal. (minimum 0.01 mt.). Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors/ all levels/ all heights. Location of sleeve shall be approved by Engineer-in-charge. PVC sleeve - 110 mm Diameter
Providing in position rigid PVC pipe sleeves of 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam before concreting. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Measurement shall be taken up to two decimal. (minimum 0.01 mt.). Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors/ all levels/ all heights. Location of sleeve shall be approved by Engineer-in-charge. PVC sleeve - 75 mm Diameter
Providing in position rigid PVC pipe sleeves of 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam before concreting. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Measurement shall be taken up to two decimal. (minimum 0.01 mt.). Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors/ all levels/ all heights. Location of sleeve shall be approved by Engineer-in-charge PVC sleeve - 50 mm Diameter
Supply and installation of CEILING HUNG cubicles of width and depth as per specifications/ site drawings. Cubicle height to be 2400 mm. Std Sizes (W x D x H): 900 mm x 1550 mm x 2400 mm, (Height is including 100 mm gap from bottom) Door Width- 600 mmITEM DESCRIPTION Made from solid grade Merino make compact high pressure laminate as per IS:2046 and EN 438 manufactured under high specific pressure > 5 MPa and temperature >120° C, All doors will be of single colour and made of 18 mm thick Merino HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. All intermediate partitions or dividers will be made of 12 mm thick Merino HPL compact laminate panels. Size of panels to be as per drawing. HARDWARE & ACCESSORIES are H shaped (Top) head frame structure made of extruded Aluminum grade 6063 T5-50 micron epoxy powder coated for surface protection. Size to be 125x70x5T. Corner joinery section, Size to be 40x16.5x1.8T. U-Channel Wall joinery section, Size to be 22x16x1.6T. Door stopper section, Size to be 21x12.5x1.6T. Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacor coated.Coat hook with rubber stopper made from Stainless steel grade 304. Surface finish to be matt type. etc complete.
Providing of Lead Lined Door system with 120x60 mm Hardwood Frames, interlayered with 3mm lead and 44mm Solid core flush door shutters conforming to the I.S. specification 2202-1991 (specification for wooden flush door shutter – solid core type), interlayered with 3mm lead with prior approval of concerned Superitending Engineer. a) Door Frame: Providing Frames for Lead Lined door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 mm with 45mm thick two layered 3mm Lead Line Sheets being overlapped from either side, spray quoted with 2 coats of Enamel paint after one coat of white wood primer of minimum 200 micron etc. complete as per direction of Engineer in Charge. with prior approval of concerned Superitending Engineer.
Providing of Lead Lined Door system with 120x60 mm Hardwood Frames, interlayered with 3mm lead and 44mm Solid core flush door shutters conforming to the I.S. specification 2202-1991 (specification for wooden flush door shutter – solid core type), interlayered with 3mm lead with prior approval of concerned Superitending Engineer b) Shutter: Supplying of ' 44mm Solid core flush door shutters conforming to the I.S. specification 2202-1991 (specification for wooden flush door shutter – solid core type). 32mm Wooden structure of 1st class Hardwood or Pinewood of at least 50mm width, top and bottom rails of 75mm width, with filler material without any gap of 1st Class Hardwood, or pine wood, all chemically treated for termite and borer resistance as per IS 401:2001 under minimum 150 PSI pressure, and seasoned as per IS 1141: 1993 upto desired moisture level as per IS 287, with one side 3mm HDF & other side 3mm lead & 6mm BWP ply; all hot-pressed with Phenol Formaldehyde resin, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of enamel paint of minimum 300 micron. with prior approval of concerned Superitending Engineer.
Providing sand stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : From Sill Level to Slab Level External
Providing & Fixing in position Acoustical Doors along with 150 x 150 mm teak wood frame, doors made from 50mm Teak wood frame 600 x600 c to c filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides, 12mm waterproof ply & veneer from both sides , including 150mm heavy duty SS hinges (Geze / Dorma or eq.) 4 no each leaf, with Door-closer (Dorma / Geze or eq.) including cost of required Cut-Outs, decorative mouldings / finishing-items / melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects .including all materials labour,finishing etc complete
Providing & Fixing in position, Acoustical Ceiling made from Rigitone 8/18 perforated panels on approved heavy duty G.I. frame, ceiling channels at 300 c to c, & intermediate channels not more than 1200 c to c, suspended with Hangers from Roof, in front of 1000 Gsm synthetic wool 50 mm thick, with Paint, including cost of required Cut-Outs, decorative mouldings / finishing-items & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects including all materials labour,finishingetc complete
Providing & Fixing in position, Acoustical Panelling made from 12mm wp Ply wood & 1.5mm laminate on, 50 x 50 mm Sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 Gsm synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete
Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work)
PRIVIDING AND FIXING ANTIMICROBIAL ACOUSTICAL FALSE CEILING: Bioguard Mineral Fibre Acoustical Suspended Ceiling System with 19mm thick Acoustics Microlook 90 Edge Tiles with 15mm face exposed grid. The tiles shall have smooth bright laminated visual with Humidity Resistance (RH) of 99%, NRC 0.7 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 41db as per ASTM E1414, Light Reflectance ≥87% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of Class 0/1 as per BS 476 Part6/7 and Class A as per ASTM E 84 with 19mm Square Tegular/Microlook 90˚ edge and 8mm drop in module size of 600 x 600mm./ 600x1200mm. The scrim on the face of the tile shall be cleanable, washable up to 500 cycle as per ASTM D-4828 and resistant to disinfectants. The tile shall be treated with Anti Microbial coating on the face of the tile to achieve cleanroom classification of class 5 (Class 100) as per ISO 14644-1 and suitable for zone 4 area having partical emission under normal conditions of ISO 5, Decontamination Class of CP10 and Bacteriological Cleanliness Class B1 for specific strains as per NF S 90-35:2003 The tile shall have a rating of 8 or above (face) for tests conducted for Resistance to growth of Mold in accordance to ASTM D3273. It shall be suitable for Green Building application, with Recycled content of 35% having VOC and Formaldehyde emission rate less than 0.1mg/m2/hr. The tile shall have certifications from GRIHA and GreenPro thereby confirming that it is an environment friendly product. SUSPENSION: The tile shall be laid on 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m.
Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- coated/good quality G.I. level adjustment clips of 35x35x0.8mm spaced @1200, center-to- center along main T all complete at all heights as per the specifications, drawings and as per The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All border cross tee/main beam shall be levelled using perimeter fill. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications above) at 1200mm maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation shall be carried out as per Manufacturer recommended procedure. SUSPENSION SYSTEM accessories supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners).
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
METAL BAFFLE CEILING : Providing & fixing of horizontal level suspended ceiling comprising of Vertical Linear Baffle Ceiling made out of Aluminum Extrusion in Aluminum alloy grade 6063 T5. The baffle blade shall be in size of 100x25x3600 in powder coated to Woodgrain/Plain finish (Red Oak, Cherry, Black & White).. The baffle shall be electrostatically polyester powder coated to a coating thickness of 60-80 micron. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation within a manufacturing batch shall be delta E<1 using Excite/BYK Gardner instrument and gloss level 25±5 at 60˚ as per ASTM D523 (Not applicable of Wood Grain Shade). The baffle blade shall be suspended using Slotted U- profile of 20 x 30 x 3700mm (Thk-1.5mm) having slots in module of 25mm to keep baffles at an on-center spacing in multiples of 25mm. Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps..SUSPENSION: Shall be hanged using baffle hanger from U-profile made of mild steel with powder coating thickness of 60-80 micron. The U – profile to comprise of alternate square & rectangular slots of 6.5x6.5mm & 28x6.5mm respectively on the web for locking the baffle hanger using plugin clip to secure the hanger in perfect position and achieve uniform spacing between baffles. The overall dimension of the U – profile is 20(W) x 30(H) x 3750(L) mm and is rolled form from 1.5mm thick mild steel with a powder coating thickness of 60- 80micron. U- Profile to be connected to each other using U –Profile Splice. The U- profile shall be hanged from the true ceiling using threaded rod using a U- Profile hanger. The Baffle along with suspension system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The supply shall be backed by a Manufacturing Test Certificate.
Providing and fixing 2 hr fire rated 122mm thick double layered dry wall partition system of approved make which includes (on both faces/ elevations) inner layer of tapered edge minimum 12.5mm thick Fire Resistant Gypsum Board having density minimum 790 kg/m3 (conforming to IS 2095 Part 1 : 2011/ EN520::2004, TYPE-F/ ASTM C1396, TYPE X) and outer layer of tapered edge 12.5mm thick calcium sulphate dihydrate encased in high gsm paper liners with glass fibers and other additives for enhanced the fire, acoustics and impact performance, third party EPD Verified as per ISO 14025, having minimum density 900 kg/m3, with maximum allowable point load on single board 25 kg to 30kg without any ply backing, complies with BS EN 520:2004 – Type A, F, D, R, I, Thermal Conductivity: 0.24 w/mºK, Thermal resistance: 0.05 m2K/w. Framing system - GI framing system consists of Close stud/ C stud of size approximate 70 x34x36x 0.5mm confirming to IS 513 having Y/S-minimum 230 Mpa, and Finish - AZ150 (IS 15961). Stud shall be placed at 600mm c/c in 72x32x32x0.5mm (approx.) floor channel and 72X32x32x0.5 mm ceiling channel. Floor & Ceiling channel is anchored to the floor & ceiling using zinc coated Rawl plug of size Ø8x45mm and having Pull out Load -7.5 kN/ anchor fasteners of required capacity as per manufacturer's specification at 600mm c/c. Floor channel to be wrapped with 70µ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. Noggin channel of 70x40x0.5mm has to be provided at the horizontal joints of the two boards and top of the board in case the top is not going up to the ceiling channel. All frame members shall be connected to each other by using metal screws. 50mm Rock wool slab of density 24kg/m³ shall be placed in metal framework. Glass wool holding clip should be used to hold Glass wool slab in its position.
Providing and fixing in position frames/ shutter for any type of aluminium work like aluminium door, composite door-window, window (sliding, openable, side hung, top hung, fixed etc.), casement window, aluminium partition, aluminium fixed louvers, fixed window with any type of aluminium sections of make Jindal/ Indal/ Hindalco as per approved make having minimum 50 micron pure polyester powder coating of approved shade, texture & colour of approved make for all floors/ all levels/ all heights/ all shapes/ all sizes including cutting, bending, crimping, fabricating in best workmanship manner etc as per the drawing, specification and as directed by Architect or Engineer-in-Charge. Rate shall be inclusive of providing aluminium sections (conventional and/ or Euro-profile sections), cutting, fabrication, errection and fixing to the best workmanship manner, including 1) Sheet metal screws and casted solid aluminum corner cleats fixed with external byttins with a spring for rapid and secure joint assembly for casement and sliding shutter and frame; 2) Glazing clips for receiving infill panel; 3) Best quality wool pile where ever shutter touches the frame and compatible microwave cured EPDM rubber; 4) Dash Anchor fasteners of HILTI or equivalent for fixing the frame assembly to the RCC or masonry surfaces. Minimum 1 anchor fastener shall be used for every 600 mm length of section for stability of frame. 5) 10mm GI tie rod for connecting vertical stile at top and bottom for aluminum door shutter and 4mm thick solid aluminium corner cleat of full thickness of section for connecting style and horizontal rails; 6) providing and fixing packing at every 600mm c/c of average 6 mm compact sheet of width (equal to section width less 30mm for backer rod and sealant); 7) Filling the gap between wall and frame on both sides (outside and inside) with polyethylene baker rod of avg. 10 mm thickness of approved make and color and then sealing the remaining gap with neutral grade G/M (Glazed & Metal) weather silicon sealant of approved make and color. 8) Termite treated seasoned teak wood as infill material to installe hardware in door shutter and frame as and when required but excluding. 1) necessary hardware; 2) Glazing or panelling material and shutter. Shop drawing shall be prepared and get approved from the consultants before procurement of material by the contractor. Work shall carried out as per the approved shop drawings and approved sample. Actual weight of installed Aluminium sections which are visible shall only be measured and shall be considered for the payment. Contractor shall provide guarantee for stability, water tightness etc for 12 months after defects liability period.
EXTERNAL WORK Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.
Providing earth work in embankment with approved materials obtained from departmental land upto lead of 50m. including all lifts, laying in layers of 20cm. to 30cm. thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller to achieve not less than 97 % of standard proctor density etc. complete ( Material obtained from departmental Land)
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.
Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader/ Paver on prepared surface, mixing by mix in placemethod with rotavator at OMC, and compacting with vibratory roller to achieve thedesired density, complete as per clause 401 -- By Mix in Place Method and Grading - III Material
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand)conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing and including preparation of sub- grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.
Providing and laying in-situ M35 Grade unreinforced plain cement concrete pavement with max 20% fly Ash ( Fly-ash upto 20% by weight of Cement) over a prepared sub basewith 43 grade cement , coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a Tilting type Concrete Mixer as per approved mix design, admixtures, spreading, laying compacting and finished in a continuous operation without paver machine, finishing to lines and grades as directed by Engineer-in charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.
Providing and fixing factory made Hydraulically pressed Mechanically vibrated and compacted precast inter locking cement concrete paving blocks 100MM thick in M-50 grade of approved size and shape for City streets and roads with high volume/ heavy traffice as specified and as per IS 15658:2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, unloading and stacking as directed, laying paving blocks in position over prepared bed of natural sand / crushed sand of 50 mm thickness including necessary excavation in all stratas, spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibrator etc. complete.
Supplying and fixing of Swareflex or equivalent Metal Road studs with shank, made of Die-cast Aluminum alloy molded body with the size of 100*100*19.8 mm, shank size 50mm, having reflective panels of 34 glass reflective elements embedded in plastic and 19 degrees tilted to provide the highest reflectivity having reflective panels in yellow, red and white plastic with yellow, red, white or green glass elements. The weight of Aluminum stud should be not less than 370 grams. The studs shall have a compressive strength test certificate of 40 tons in accordance with ASTDM D 4280-04 and successfully passing retro reflectivity test as per EN 1463 part 1 & part 2, from a reputed international laboratory . The bidder shall attach a product warranty certificate against Breakage and loss of reflectivity from the manufacturer for 3 years from installation. The fixing of road studs shall be done by using a recommended Two Component Epoxy after drilling 60 mm hole on the road for the shank to go inside.
Providing and applying Cold plastic paint two component rolled on surfacing material solvent free,high build two pack seamless,tough,skid resistant,material with has property of attaining 2.00mm thickness in single coat application white(or as required colour )based on glass and colour retaining acralic cross linking resin system for coloured road surfacing including surface cleaning and cost of all material etc. complete. (All inclusive on bitumen or concrete surface) work shall carried out as per IRC 35-2015 clause 2.2)
Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering with sprinkler and maintenance for 30 days or more till t
Preparation and plantation of required variety of trees including excavation pit size 0.6 x0.60 x0.60, supplying on-site fresh Garden soil and well decomposed Farm Yard Manure FYM, mixing garden soil & manure, Filing fresh garden soil and manure in excavated area with maintenance of newly planted trees for the period 36 months till well established including mortality of plant materials, material supply on site must be approved by Horticulturist / Garden in charge & should be certified by competent authority. etc complete.(RA No. 1)
Supply of following capacity (continous loading) BEE 4 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI Marked and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 35 dg.C for oil and 40 dg. C up to 200 KVA and 40 dg.C for oil and 45 dg. C for above 200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shallbe used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminum/ stainless steel material securely fixed on the outer body, easily accessible,as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked. Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c)Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o)Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652– 2006 having 2.5 mm thickness up to 11 kV
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(UE), 3 x 185 sq. mm. aluminium conductor laid in provided trench / pipe
Providing and erecting Heat shrinkable indoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification
Providing and erecting Heat shrinkable outdoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification
Providing and erecting Heat shrinkable straight through joint kit for 11 kV (UE)/22 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification
Supplying, erecting and commissioning of diesel generating set with alternator of 2000 kVA input continuous rating, 3 phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722- 2001 with voltage regulation +/- 5 %. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising of meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level upto 75 dB at 1.0 m, provided with first filling of oil, diesel day tank, exaust piping with support upto the terrace, control cabling etc. and obtaining necessary approval from Electrical inspector / MPCB as per specification.
Supply & installation of suitable Exhaust pipe, B class, 12" MS ERW pipe (as per IS 3589) including all bends, etc.
Supply & installation of Insulation of Exhaust pipe with 24 gauge Al sheet with 100kg/m3 rockwool density , 50mm thk for 8" pipe.
Supply & Installation of insulation for silencer with 24 gauge Al sheet with 100kg/m3 rockwool density , 50mm.
Supply & installation of S.S BELLOW 12'' with required mounting accessories.
Supply & installation of MS structure for exhaust pipe, silencer, Fuel tank, Fuel pipe, cable tray etc. (Painting with one coat of Primer and 2 coats of Enamel aluminium Paint is applicable only on MS structure).
Supply, installation, Testing and Commissioning of ISOLATER PANEL I/C- 3200A 4P MP, 50kA. ACB - 1 Nos , 3200A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control (Cabling provision for BMS to be considered), CT for metering, control wiring. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM..
Supply, installation, Testing and Commissioning of ATS PANEL 3200A 4P SOLENOID DRAW OUT TYPE ATS - 1 Nos , 3200A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB. The Panel shall complying to latest IEC standards & It should be verified by OEM..
Supply, installation, Testing and Commissioning of MAIN LT PANEL-1. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. MAIN LT PANEL-1 I/C 3200A, 4P, 50kA, EDO, LSIG ACB - 3 No 4000A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. BUSCOUPLER of 3200A, 4P, 50kA, EDO, LSIG ACB - 2 No with on/off/trip indication lamp O/G- 3200A, 4P, 50kA, EDO, LSIG ACB - 05 No 1600A, 4P, 50kA, EDO, LSIG ACB - 03 No 1250A, 4P, 50kA, EDO, LSIG ACB - 03 No 1000A, 4P, 50kA, EDO, LSIG ACB - 01 No 800A, 4P, 50kA, EDO, LSIG ACB - 01 No 630A, 4P, 50kA,MP,MCCB - 01 No 200A, 4P, 50kA, MP- MCCB -01 No 100A, 4P, 50kA, MP, MCCB - 01 No
Supply, installation, Testing and Commissioning of MAIN LT PANEL-2. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. MAIN LT PANEL-2 I/C 3200A, 4P, 50kA, EDO, LSIG ACB - 3 No 4000A 50kA TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. BUSCOUPLER of 3200A, 4P, 50kA, EDO, LSIG ACB - 2 No with on/off/trip indication lamp O/G-3200A, 4P, 50kA, EDO, LSIG ACB - 05 No 2500A, 4P, 50kA, EDO, LSIG ACB - 01 No 1600A, 4P, 50kA, EDO, LSIG ACB - 01 No 1250A, 4P, 50kA, EDO, LSIG ACB - 04 No 800A, 4P, 50kA, EDO, LSIG ACB - 02 No 630A, 4P,50kA, TM, MCCB - 01 No 400A, 4P, 50kA, TM,MCCB - 01 No 200A, 4P, 50kA,TM, MCCB - 01 No 100A, 4P, 50kA,TM,MCCB- 01 No
Supply, installation, Testing and Commissioning of EMERGENCY PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS control (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. EMERGENCY PANEL- I/C- 2500A 4P MP, 50kA,ACB - 1 Nos & 1000A 4P MP, 50kA,ACB - 1 Nos with Electrical & Mechanical Interlocking 2500A 50kA TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. BUSCOUPLER of 2500A, 4P, 50kA, EDO, LSIG ACB - 1 No with on/off/trip indication lamp O/G- 630A FP MCCB 36kA TM BASED - 04 Nos 400A FP MCCB 36kA TM BASED - 04 Nos 200A FP MCCB 36kA TM BASED - 01 Nos 100A FP MCCB 36kA TM BASED - 01 Nos
Supply, installation, Testing and Commissioning of LIFT PANEL-1&2. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below. LIFT PANEL- 1 & 2 I/C- 400A 4P MP, 36kA. MCCB - 1 Nos 400A 36kA TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 63A FP MCB 10kA - 15 Nos 100A FP MCCB 25kA - 01Nos
Supply, installation, Testing and Commissioning of STACK PARKING PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below. STACK PARKING PANEL- I/C- 630A 4P MP, 36kA. MCCB - 1 Nos 630A 36kA TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 400A FP 36kA TM BASED MCCB - 13 Nos
Supply, installation, Testing and Commissioning of EV CHARGING PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below. EV CHARGING PANEL- I/C-630A 4P MP, 36kA. MCCB - 1 Nos 630A 36kA TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G-100A FP MCCB 25kA - 11 Nos
Supply, installation, Testing and Commissioning of BASEMENT VENTILATION FAN DISTRIBUTION PANEL. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below. BASEMENT VENTILATION FAN DISTRIBUTION PANEL- I/C- 630A 4P MP, 36kA. MCCB - 1 Nos 630A 36kA TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 200A FP 25kA TM BASED MCCB-07 Nos
Supply, installation, Testing and Commissioning of 700 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection as per specification no CP-ED/APFC
Supply, installation, Testing and Commissioning of BASEMENT FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. BASEMENT FLOOR -L & P PANEL- BLOCK-A I/C- 100A 4P MP, 25kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 100A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 63A FP MCB 10KA - 10 Nos
Supply, installation, Testing and Commissioning of BASEMENT FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. BASEMENT FLOOR -L & P PANEL- BLOCK-B I/C- 100A 4P MP, 25kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 100A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 63A FP MCB 10KA - 10 Nos
Supply, installation, Testing and Commissioning of GROUND FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. GROUND FLOOR -L & P PANEL- BLOCK-A I/C- 800A 4P MP, 25KA. ACB - 2 Nos with Electrical & Mechanical Interlocking 800A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 250A FP MCCB 16kA TM BASED - 02 Nos 100A FP MCCB 25kA TM BASED MCCB - 05 Nos 63A FP MCB 10KA - 06 Nos
Supply, installation, Testing and Commissioning of GROUND FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. GROUND FLOOR -L & P PANEL- BLOCK-B I/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 200A FP MCCB 25kA TM BASED MCCB - 02 Nos 100A FP MCCB 25kA TM BASED MCCB - 04 Nos 63A FP MCB 10KA - 08 Nos
Supply, installation, Testing and Commissioning of FIRST FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. FIRST FLOOR -L & P PANEL- BLOCK-A I/C- 400A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP MCCB 25kA TM BASED MCCB - 05 Nos 63A FP MCB 10KA - 05 Nos
Supply, installation, Testing and Commissioning of FIRST FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. FIRST FLOOR -L & P PANEL- BLOCK-B I/C- 400A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 400A FP MCCB 25KA TM BASED MCCB - 02 Nos 100A FP MCCB 16kA TM BASED MCCB - 05 Nos 63A FP MCB 10KA - 05 Nos
Supply, installation, Testing and Commissioning of SECOND FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. SECOND FLOOR -L & P PANEL- BLOCK-A I/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP MCCB 25kA TM BASED MCCB - 06 Nos 63A FP MCB 10KA - 04 Nos
Supply, installation, Testing and Commissioning of SECOND FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. SECOND FLOOR -L & P PANEL- BLOCK-B I/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 200A FP MCCB 25kA TM BASED MCCB - 02 Nos 100A FP MCCB 25kA TM BASED MCCB - 06 Nos 63A FP MCB 10KA - 03 Nos
Supply, installation, Testing and Commissioning of THIRD FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. THIRD FLOOR -L & P PANEL- BLOCK-A I/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP MCCB 25kA TM BASED MCCB - 05 Nos 63A FP MCB 10KA - 05 Nos
Supply, installation, Testing and Commissioning of THIRD FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. THIRD FLOOR -L & P PANEL- BLOCK-B I/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP MCCB 25kA TM BASED MCCB - 07 Nos 63A FP MCB 10KA - 04 Nos
Supply, installation, Testing and Commissioning of FOURTH, FIFTH, SIXTH, & SEVENTH FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. FOURTH, FIFTH, SIXTH, & SEVENTH FLOOR -L & P PANEL- BLOCK-A I/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 200A FP MCCB 25kA TM BASED MCCB - 02 Nos 63A FP MCB 10KA - 10 Nos
Supply, installation, Testing and Commissioning of FOURTH, FIFTH, SIXTH, & SEVENTH FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. FOURTH, FIFTH, SIXTH, & SEVENTH FLOOR -L & P PANEL- BLOCK-B I/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 200A FP MCCB 25kA TM BASED MCCB - 02 Nos 100A FP MCCB 25kA TM BASED MCCB - 01 Nos 63A FP MCB 10KA - 08 Nos
Supply, installation, Testing and Commissioning of EIGTH FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. EIGHTH FLOOR -L & P PANEL- BLOCK-A I/C-800A 4P MP, 25KA. ACB - 2 Nos with Electrical & Mechanical Interlocking 800A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP MCCB 25kA TM BASED MCCB - 08 Nos 63A FP MCB 10KA - 06 Nos
Supply, installation, Testing and Commissioning of EIGTH FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. EIGHTH FLOOR -L & P PANEL- BLOCK-B I/C-800A 4P MP, 25KA. ACB - 2 Nos with Electrical & Mechanical Interlocking 800A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP MCCB 25kA TM BASED MCCB - 06 Nos 200A FP MCCB 25kA TM BASED MCCB - 01 Nos 63A FP MCB 10KA - 07 Nos
Supply, installation, Testing and Commissioning of NINTH FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. NINTH FLOOR -L & P PANEL- BLOCK-A I/C- 400A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 200A FP MCCB 25kA TM BASED MCCB - 03 Nos 100A FP MCCB 25kA TM BASED MCCB - 02 Nos 63A FP MCB 10KA - 07 Nos
Supply, installation, Testing and Commissioning of NINTH FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. NINTH FLOOR -L & P PANEL- BLOCK-B I/C- 400A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 200A FP MCCB 25kA TM BASED MCCB - 02 Nos 100A FP MCCB 25kA TM BASED MCCB - 03 Nos 63A FP MCB 10KA - 05 Nos
Supply, installation, Testing and Commissioning of TENTH FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. TENTH FLOOR -L & P PANEL- BLOCK-A I/C- 200A 4P MP, 25kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 200A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 63A FP MCB 10KA - 10 Nos 100A FP MCCB 25kA TM BASED MCCB - 01 Nos 200A FP MCCB 25kA TM BASED MCCB - 01 Nos
Supply, installation, Testing and Commissioning of TENTH FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. TENTH FLOOR -L & P PANEL- BLOCK-B I/C- 250A 4P MP, 25kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 250A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 63A FP MCB 10KA - 08 Nos 100A FP MCCB 25kA TM BASED MCCB - 02 Nos 200A FP MCCB 25kA TM BASED MCCB - 02 Nos
Supply, installation, Testing and Commissioning of ELEVENTH FLOOR -L & P PANEL- BLOCK-A & B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. ELEVENTH FLOOR -L & P PANEL- BLOCK-A & BLOCK-B I/C- 400A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 200A FP MCCB 25kA TM BASED MCCB - 03 Nos 100A FP MCCB 25kA TM BASED MCCB - 01 Nos 63A FP MCB 10KA - 08 Nos
Supply, installation, Testing and Commissioning of TWELFTH FLOOR -L & P PANEL- BLOCK-A. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. TWELFTH FLOOR -L & P PANEL- BLOCK-A I/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP MCCB 25kA TM BASED MCCB - 01 Nos 63A FP MCB 10KA - 14 Nos
Supply, installation, Testing and Commissioning of TWELFTH FLOOR -L & P PANEL- BLOCK-B. All incomer & outgoing shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. TWELFTH FLOOR -L & P PANEL- BLOCK-B I/C- 630A 4P MP, 25KA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP MCCB 25kA TM BASED MCCB - 01 Nos 200A FP MCCB 25kA TM BASED MCCB - 03 Nos 63A FP MCB 10KA - 10 Nos
Supply, installation, Testing and Commissioning of GROUND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. GROUND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A - I/C- 200A 4P MP, 25kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking. 200A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 200A FP MCCB 25kA TM BASED - 02 Nos 100A FP MCCB 25kA TM BASED - 07 Nos All outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp.
Supply, installation, Testing and Commissioning of GROUND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. GROUND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B - I/C- 1600A 4P MP, 25KA. ACB - 2 Nos with Electrical & Mechanical Interlocking. 1600A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 630A FP MCCB 25KA TM BASED - 02 Nos 400A FP MCCB 25KA TM BASED - 04 Nos 200A FP MCCB 25kA TM BASED - 05 Nos 100A FP MCCB 25kA TM BASED - 03 Nos All outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp.
Supply, installation, Testing and Commissioning of FIRST FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. FIRST FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A-I/C- 1600A 4P MP, 25KA. ACB - 2 Nos with Electrical & Mechanical Interlocking 1600A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 630A FP MCCB 25KA TM BASED - 02 Nos 400A FP MCCB 25KA TM BASED - 04 Nos 200A FP MCCB 25kA TM BASED - 05 Nos 100A FP MCCB 25kA TM BASED - 03 Nos All outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp.
Supply, installation, Testing and Commissioning of FIRST FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. FIRST FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B - I/C- 1600A 4P MP, 25KA. ACB - 2 Nos with Electrical & Mechanical Interlocking . 1600A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 630A FP MCCB 25KA TM BASED - 02 Nos 400A FP MCCB 25KA TM BASED - 04 Nos 200A FP MCCB 25kA TM BASED - 05 Nos 100A FP MCCB 25kA TM BASED - 03 Nos All outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp.
Supply, installation, Testing and Commissioning of SECOND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. SECOND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A- I/C- 630A 4P MP, 25KA.MCCB - 2 Nos with Electrical & Mechanical Interlocking 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 200A FP MCCB 25kA TM BASED - 04 Nos 100A FP MCCB 25kA TM BASED - 06 Nos All outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp.
Supply, installation, Testing and Commissioning of SECOND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. SECOND FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B - I/C- 400A 4P MP, 25KA.MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 200A FP MCCB 25kA TM BASED - 02 Nos 100A FP MCCB 25kA TM BASED - 05 Nos All outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp.
Supply, installation, Testing and Commissioning of THIRD FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. THIRD FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A - I/C- 200A 4P MP, 25kA.MCCB - 2 Nos with Electrical & Mechanical Interlocking 200A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP MCCB 25kA TM BASED - 05 Nos All outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp.
Supply, installation, Testing and Commissioning of NINTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. NINTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A - I/C- 400A 4P MP, 25KA.MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP MCCB 25kA TM BASED - 11 Nos All outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp.
Supply, installation, Testing and Commissioning of NINTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. NINTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B I/C- 400A 4P MP, 25KA.MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP MCCB 25kA TM BASED - 11 Nos All outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp.
Supply, installation, Testing and Commissioning of ELEVENTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. ELEVENTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-A- I/C- 400A 4P MP, 25KA.MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP MCCB 25kA TM BASED - 11 Nos All outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp.
Supply, installation, Testing and Commissioning of ELEVENTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 25KA and consist of the switchgear as mentioned below. ELEVENTH FLOOR -MEDICAL EQUIPMENT PANEL- BLOCK-B - I/C- 400A 4P MP, 25KA.MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP MCCB 25kA TM BASED - 11 Nos All outgoing shall have on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp.
Supply, installation, Testing and Commissioning of AHU PANEL. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below. AHU PANEL- BLOCK- A & BLOCK- B - I/C-400A 4P MP, 36kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP 25kA TM BASED MCCB-12 Nos All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB.
Supply, installation, Testing and Commissioning of AHU PANEL. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below. AHU PANEL- BLOCK- A & BLOCK- B - I/C- 250A 4P MP, 36kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 250A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP 25kA TM BASED MCCB-12 Nos All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB.
Supply, installation, Testing and Commissioning of AHU PANEL. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below. AHU PANEL- BLOCK- A & BLOCK- B - I/C- 100A 4P MP, 25kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 100A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 63A FP 25kA TM BASED MCCB-12 Nos All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB.
Supply, installation, Testing and Commissioning of AHU PANEL. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below. AHU PANEL- BLOCK- A & BLOCK- B - I/C- 200A 4P MP, 25kA. MCCB - 2 Nos with Electrical & Mechanical Interlocking 200A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 100A FP 25kA TM BASED MCCB-8 Nos All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB.
Supply, installation, Testing and Commissioning of PLUMBING PANEL. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below. PLUMBING PANEL- I/C- 200A 4P MP, 25kA. MCCB - 1 Nos 200A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 16 nos of MCCB/MPCB wih starter SUITABLE FOR 10HP MOTOR as per type 2 Coordination chart + 3 SPARE of same rating (Provision only) All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB.
Supply, installation, Testing and Commissioning of BASEMENT VENTILATION PANEL. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below. BASEMENT VENTILATION PANEL- I/C- 400A 4P MP, 36kA. MCCB - 1 Nos 400A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 6 nos of MCCB/MPCB with starter SUITABLE FOR 20HP MOTOR + 2 SPARE for same rating (Provision only) & 5 nos of MCCB/MPCB with starter SUITABLE FOR 4HP MOTOR as per type 2 Coordination chart + 2 SPARE for same rating (Provision only) All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB.
Supply, installation, Testing and Commissioning of STAIRCASE LIFT PRESSURISATION PANEL. All incomer shall have RYB phase indicator lamp with MCB, on / off / trip indicator lamp with MCB, Digital MFM compatible for BMS contro (Cabling provision for BMS to be considered), CT for metering, control wiring. All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB. The panel shall consist of IP42 rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and colour coded with Heat shri shrinkable sleeves. The Panel shall TTA complying to latest IEC standards of 61439 & It should be verified by OEM.. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below. STAIRCASE LIFT PRESSURISATION PANEL- I/C- 630A 4P MP, 36kA. MCCB - 1 Nos 630A TPN AL BUSBAR. BUSBAR SHALL BE TIN PLATED WITH SILVER CONTACTS. O/G- 4 nos of MCCB/MPCB with starter SUITABLE FOR 40HP MOTOR + 1 SPARE (Provision only), 3 nos of MCCB/MPCB with starter SUITABLE FOR 20HP MOTOR + 1 SPARE (Provision only), 12 nos of MCCB/MPCB with starter SUITABLE FOR 7HP Motor & 2 nos of MCCB/MPCB with starter SUITABLE FOR 16HP Motor as per type 2 Coordination chart + 1 SPARE (Provision only) All MCB outgoings shall have ON indication lamp. All MCCB outgoings shall have on / off / trip indicator lamp with MCB.
Supply, installation, testing & commissioning of VFDs.VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-65 enclosure (for outdoor applications) & IP-20 enclosure (for indoor applications) for use on AHU fans. The display should be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. VFD’s shall have built-in harmonic filters with THDI less than 5%. No. VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption. No. VFD shall be installed in a dedicated external/internal enclosure and the inter connecting wires between driver and MCC shall be included. Necessary transformer, power adapters, sensors, relay etc. as required for satisfactory operation shall be in the scope of VFD supplier. It should be BMS Compatible. 10.0 HP/ 7.5 KW
Supply, installation, testing & commissioning of VFDs.VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-65 enclosure (for outdoor applications) & IP-20 enclosure (for indoor applications) for use on AHU fans. The display should be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. VFD’s shall have built-in harmonic filters with THDI less than 5%. No. VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption. No. VFD shall be installed in a dedicated external/internal enclosure and the inter connecting wires between driver and MCC shall be included. Necessary transformer, power adapters, sensors, relay etc. as required for satisfactory operation shall be in the scope of VFD supplier. It should be BMS Compatible. 7.5 HP/ 5.6 KW
Supply, installation, testing & commissioning of VFDs.VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-65 enclosure (for outdoor applications) & IP-20 enclosure (for indoor applications) for use on AHU fans. The display should be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. VFD’s shall have built-in harmonic filters with THDI less than 5%. No. VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption. No. VFD shall be installed in a dedicated external/internal enclosure and the inter connecting wires between driver and MCC shall be included. Necessary transformer, power adapters, sensors, relay etc. as required for satisfactory operation shall be in the scope of VFD supplier. It should be BMS Compatible. 5.0 HP/ 3.73 KW
Supply, installation, testing & commissioning of VFDs.VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-65 enclosure (for outdoor applications) & IP-20 enclosure (for indoor applications) for use on AHU fans. The display should be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. VFD’s shall have built-in harmonic filters with THDI less than 5%. No. VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption. No. VFD shall be installed in a dedicated external/internal enclosure and the inter connecting wires between driver and MCC shall be included. Necessary transformer, power adapters, sensors, relay etc. as required for satisfactory operation shall be in the scope of VFD supplier. It should be BMS Compatible. 3.0 HP/ 2.2 KW and below rating
Supplying, installing, testing and commissioning air circuit breaker manual drawout type, 650V, 1250A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA (Ics=Icu=Icw for 1s),with standard accessories with ready to close, individual fault trip, alarm and trip indications, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB
Supplying, installing, testing and commissioning air circuit breaker manual drawout type, 650V, 1000A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA (Ics=Icu=Icw for 1s),with standard accessories with ready to close indication, individual fault trip indication, indications for alarm and trip, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB
Supplying, installing, testing and commissioning air circuit breaker manual drawout type, 650V, up to 800A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection), 50 kA (Ics=Icu=Icw for 1s),with standard accessories and with ready to close, individual fault trip, alarm and trip indication, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-OffTrip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB
Providing & erecting 3 Pole MCCB 415V, 630A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no.
Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting terminal spreaders suitable for 4 pole, above 100A up to 250A MCCB (Set of 8)
Supplying and erecting terminal spreaders suitable for 4 pole, above 250A up to 400A MCCB (Set of 8)
Supplying and erecting terminal spreaders suitable for 4 pole, above 400A up to 630A MCCB (Set of 8)
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc. For On/Off /Trip.
Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP BB
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supply, installation, testing and commissioning of Aluminum 250A 40kA SC for 1 sec Air Insulated type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 250A 40kA Air Insulated type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 250A 40kA Air Insulated type BBT.
Supply, installation, testing and commissioning of End Feed Unit as per design requirement & site condition suitable for Aluminum 250A 40kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 250A 40kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 250A 40kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 250A 40kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Aluminum 400A 40kA SC for 1 sec Air Insulated type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 400A 40kA Air Insulated type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 400A 40kA Air Insulated type BBT.
Supply, installation, testing and commissioning of End Feed Unit as per design requirement & site condition suitable for Aluminum 400A 40kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 400A 40kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 400A 40kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 400A 40kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Aluminum 800A 40kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 800A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 800A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of End Feed Unit as per design requirement & site condition suitable for Aluminum 800A 40kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 800A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 800A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 800A 40kA Sandwich type BBT.
Supply, installation, testing and commissioning of Aluminum 1000A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 1000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 1000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of End Feed Unit as per design requirement & site condition suitable for Aluminum 1000A 50kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 1000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 1000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 1000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Aluminum 1250A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 1250A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 1250A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of End Feed Unit as per design requirement & site condition suitable for Aluminum 1250A 50kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 1250A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 1250A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 1250A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Aluminum 1600A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 1600A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 1600A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of End Feed Unit as per design requirement & site condition suitable for Aluminum 1600A 50kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 1600A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 1600A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 1600A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Aluminum 2000A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 2000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 2000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of End Feed Unit as per design requirement & site condition suitable for Aluminum 2000A 50kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 2000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 2000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 2000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Aluminum 2500A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers / end caps as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 2500A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 2500A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of End Feed Unit as per design requirement & site condition suitable for Aluminum 2500A 50kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 2000A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 2500A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 2500A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Aluminum 3200A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 54 indoor. The total bus bar assembly & installaion at site must comply Seismic zone 4. Straight length of feeder / plug in type with hanging brackets, end covers as per design requirement & site condition
Supply, installation, testing and commissioning of Aluminum3200A 50kA SC for 1 sec Sandwich type BBT. The BBT should be totally type tested as per IEC 61439-6. The Bus bar trunking must be with Copper/ Bimetal Contact, with Tin plated Aluminium (3L+N+PE) 100% N with 50% Integral / Internal Earth. The BBT must be of insulation Class F & operating voltage = 1000V,Impulse withstand of 8kV & Housing of minimum 1.5mm Electro-galvanized steel. The housing enclosure must be electrostatic powder coated of suitable shade. The BBT must of IP 65 for outdoor with canopy. The total bus bar assembly & installaion at site must comply Seismic zone 4 or above. Straight length of feeder / plug in type with hanging brackets, end covers as per design requirement & site condition
Supply, installation, testing and commissioning of Flange end with Adaptor box, Copper flexibles as per design requirement & site condition suitable for Aluminum 3200A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of 90 Degree Elbow / T Elbow as per design requirement & site condition suitable for Aluminum 3200A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of End Feed Unit as per design requirement & site condition suitable for Aluminum 3200A 50kA Air Insulated type BBT.
Supply, installation, testing and commissioning of Phase cross over/ expansion joint as per design requirement & site condition suitable for Aluminum 3200A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Support hanger as per site condition suitable for vertical Aluminum 3200A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Fabrication Support & hardware suitable for Aluminum 3200A 50kA Sandwich type BBT.
Supply, installation, testing and commissioning of Tap off box tested as per IEC 61439-6 of 100 A Tap off box (IP-54) made of 1.6mm thick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4P LSI with earthing connection point & safelty interlock
Supply, installation, testing and commissioning of Tap off box tested as per IEC 61439-6 of 200 A Tap off box (IP-54) made of 1.6mm thick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4P LSI with earthing connection point & safelty interlock
Supply, installation, testing and commissioning of Tap off box tested as per IEC 61439-6 of 250 A Tap off box (IP-54) made of 1.6mm thick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4P LSI with earthing connection point & safelty interlock
Supply, installation, testing and commissioning of Tap off box tested as per IEC 61439-6 of 400 A Tap off box (IP-54) made of 1.6mm thick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4P LSI with earthing connection point & safelty interlock
Supply, installation, testing and commissioning of Tap off box tested as per IEC 61439-6 of 630 A Tap off box (IP-54) made of 1.6mm thick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4P LSI with earthing connection point & safelty interlock
Supply, installation, testing and commissioning of Tap off box tested as per IEC 61439-6 of 800 A Tap off box (IP-54) made of 1.6mm thick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4P LSI with earthing connection point & safelty interlock
Supply, installation, testing and commissioning of Tap off box tested as per IEC 61439-6 of 1600 A Tap off box (IP-54) made of 1.6mm thick sheet steel enclosure duly powder coating on existing rising mains complete with 4P MCCB, 36kA 4P LSI with earthing connection point & safelty interlock
Supply, installation, Testing & commissioning of 10KVA UPS . as per IS 13314 & IS 11260 having following capacity & features:- Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output. UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quoted price shall be inclusive of required rating single core copper conductor cable including terminations,connections of UPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge.
Supply, installation, Testing & commissioning of 15KVA UPS . as per IS 13314 & IS 11260 having following capacity & features:- Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output. UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quoted price shall be inclusive of required rating single core copper conductor cable including terminations,connections of UPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge.
Supply, installation, Testing & commissioning of 20KVA UPS . as per IS 13314 & IS 11260 having following capacity & features:- Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output. UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quoted price shall be inclusive of required rating single core copper conductor cable including terminations,connections of UPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge.
Supply, installation, Testing & commissioning of 30KVA UPS . as per IS 13314 & IS 11260 having following capacity & features:- Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output. UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quoted price shall be inclusive of required rating single core copper conductor cable including terminations,connections of UPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge.
Supply, installation, Testing & commissioning of 40KVA UPS . as per IS 13314 & IS 11260 having following capacity & features:- Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output. UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quoted price shall be inclusive of required rating single core copper conductor cable including terminations,connections of UPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge.
Supply, installation, Testing & commissioning of 60KVA UPS . as per IS 13314 & IS 11260 having following capacity & features:- Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output. UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quoted price shall be inclusive of required rating single core copper conductor cable including terminations,connections of UPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge.
Supply, installation, Testing & commissioning of 80KVA UPS . as per IS 13314 & IS 11260 having following capacity & features:- Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output. UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quoted price shall be inclusive of required rating single core copper conductor cable including terminations,connections of UPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge.
Supply, installation, Testing & commissioning of 120KVA UPS . as per IS 13314 & IS 11260 having following capacity & features:- Load 0.8 PF, Full wave / pure sine wave IGBT base rectifier, Isolator Transformer Input THDI < 5% & Input Power factor @ 0.99 With Automatic Internal Static Bypass switch. The static switches shall be rated for 125% continuous Load & should take care of Current imbalance due to power cable impedance. This should provide High availability for system, Manual maintenance switch at input & output. UPS shall sustain input voltage variations from + 20 % & +20% without switching over to batteries and providing output voltage with +/- 1 % regulation, UPS shall be able to sustain input frequency variation of +/- 6 % (Min), The Maximum waveform distortion (THD) of output voltage shall not exceed 3 % RMS for Linear Loads and 5 % RMS for non linear Loads, Output Frequency – 50 Hz ( Mains Synchronized) , +/-0.1 % Free Running. Quoted price shall be inclusive of required rating single core copper conductor cable including terminations,connections of UPS to batteries, battery rack etc complete in all respect and as per direction of Engineer in Charge.
Supplying and erecting 12V/42Ah SMF battery with battery terminal wire,duly charged with 24 months warranty complete
Supplying and erecting 12V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 400 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 3 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 3 core 10 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 4 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No.CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No.CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification No.CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material as per specification No. CB-JT/LT
Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 25 to 50 sq mm., with necessary material as per specification No. CB-JT/LT
Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 70 to 95 sq mm., with necessary material as per specification No. CB-JT/LT
Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 120 to 185 sq. mm., with necessary material as per specification No. CB-JT/LT
Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 240 sq.mm., with necessary material as per specification No. CB-JT/LT
Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 300 sq mm., with necessary material as per specification No. CB-JT/LT
Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 400 sq mm., with necessary material as per specification No. CB-JT/LT
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material as per specification No. CB-JT/LT
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 25 to 50 sq mm., with necessary material as per specification No. CB-JT/LT
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 70 to 120 sq mm., with necessary material as per specification No. CB-JT/LT
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 150 to 185 sq mm., with necessary material as per specification No. CB-JT/LT
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 240 to 300 sq mm., with necessary material as per specification no. CB-JT/LT
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 400 sq mm., with necessary material as per specification No. CB-JT/LT
Providing & erecting hot dipped galvanised perforated type cable tray manufactured from16SWG GI sheet of 150mm width & 75mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised perforated type cable tray manufactured from16 SWG GI sheet of 200mm width & 75mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised perforated type cable tray manufactured from 16SWG GI sheet of 300mm width & 75mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised perforated type cable tray manufactured from16SWG GI sheet of 500mm width &75mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 200 mm width & 20 mm height complete with necessary hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 500 mm width & 20 mm height complete with necessary hardware.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16SWG GI sheet of 200mm width & 100mm height with required standard accessories.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16SWG GI sheet of 400mm width & 100mm heightwith required standard accessories.
8 WAY SPN DB Supplying and erecting single pole and neutral distribution board (SPNDB) surface/flush mounted with 2 poles for incoming and 6 poles for outgoing SP MCB‟s on iron/ GI frame as per specification no. SW-SWR/MCBDB
12 WAY SPN DB Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 poles for incoming and 10 poles for outgoing SP MCB‟s on iron/ GI frame as per specification no. SW-SWR/MCBDB
4 WAY TPN DB Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 12 poles, on iron /GI frame (horizontal busbar type) as per specification no.SW-SWR/MCBDB
8 WAY TPN DB Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 24 poles, on iron/ GI frame/wooden board.(horizontal busbar type) as perspecification no. SW-SWR/MCBDB
12 WAY TPN DB Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 36 poles on iron/ GI frame (horizontal busbar type) as per specification no.SW-SWR/MCBDB
4 WAY VTPN DB Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted SP/TP MCBs of 12 poles/4 ways on iron / GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
8 WAY VTPN DB Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted SP / TP of 24 poles/ 8 ways on iron / GI frame (vertical busbar type) as per specificationno. SW-SWR/MCBDB
12 WAY VTPN DB Supplying & erecting triple pole and neutral distribution board(TPNDB) surface/ flush mounted SP / TP MCB of 36 poles/12ways on iron / GI frame (vertical busbar type) as per specificationno. SW-SWR/MCBDB
Supplying, erecting & marking SPMCB 6A to 32A, C-series (formotor / power) in provided distribution board as per specificationno. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/MCB
Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 6A to 32A, with rated short- circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short- circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, fixing and commissioning 2 pole,RCBO (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 6/10/16/20/25A, as per specification no SWRCCB/RCBO
Supplying, fixing and commissioning 2 pole RCBO (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 32A/40A as per specification no SW-RCCB/RCBO
Supplying, fixing and commissioning 2 pole RCBO (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 63A, as per specification no SW-RCCB/RCBO
Supplying, fixing and commissioning 4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 32A/40A as per specification no SW-RCCB/RCBO
Supplying, fixing and commissioning 4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 63A as per specification no SW-RCCB/RCBO
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ HW. Average Length 6M.
Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW. Average Length 8M.
Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW. Average Length 10M.
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit / trunking / insidepole / Busbars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 3x4sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking /insidepole / Busbars or anyother places as per specification No: WG-MA/BW
Supplying and erecting mains with 3x6sq.mm FRLSH copper PVC insulated wire laid in provided conduit / trunking/ insidepole / Busbars or anyother places as per specification No: WG-MA/BW
Supplying and erecting mains with 3x10sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Busbars or any other places as per specification No: WG-MA/BW
Concealing of provided G.I. pipe/H.G. screwed conduit/PVC pipe in wall/floor/false ceiling complete as per specification No: WG-PW/CW
Supplying and erectingHMS PVC conduit FRLSgrade 20mmdia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 25mm dia.with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erectingHMSPVCconduit FRLSgrade 32mmdia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Wiring for plug on board with modular Switch socket concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
Supplying and erecting modular type switch 6A/10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting lumiNous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230V A.C. supply with resetting arrangement complete erected on double wooden/ sunmica board
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background..
Supplying and erecting unbreakable concealed type modular switch box withdouble mounting plate for 2 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box withdouble mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box withdouble mounting plate for 12 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting CRCA /die-cast aluminium powder coated housing Bottom Opening Clean Room LED Luminaries 24 W with provision for plane front frame with translucent cover fixed to the housing complete.(indirect light)
Supplying and erecting CRCA /die-cast aluminium powder coated housing Bottom Opening Clean Room LED Luminaries 36 W with provision for plane front frame with translucent cover fixed to the housing complete.(indirect light)
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty
Supplying & erecting UV Fly killer/ bug catcher Light Fitting having 2 x 20W UV Tube Lights to cover min. area of 500 sq.ft with powdered coated M.S./ steel body suitable to work on 230V, AC Supply having top mounting arrangement with SS chain complete and 3 core 1 mtr. flexible wire with 1 year warranty
Supplying and erecting regular / standard model ceiling fan of 900/1050mm. sweep complete erected in position as per specification no. FG-FN/CF
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Supplying and erecting regular/standard model ceiling fan of 1400mm sweep complete erected in position as per specification no. FG-FN/CF
Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan.
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia.or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and within any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting „B‟ class G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting cabin fan of A.C. 230 V. 50 cycles 250 mm. /300 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc
Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF
Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification no. OHPL/ OPL
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OHPL/ PBKT
Supplying and erecting integrated LED street light fitting 160-170W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 19000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140 270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG ODF/FLS2.
Supplying & erecting water tight terminal box of 1.6 mm (16 gauge) CRCA sheet of size 150 x 100 x 100 mm complete on pole as per specification no. CB-SB with Bakelite connector.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles)
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/30A single pole MCB having rated short- circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame.
Supplying, erecting, testing and commissioning selfcontained water cooler 230/250 V 50 cycles nominal cooling capacity of 80 litres/hr and storage capacity 120 litres with partially stainless steel body complete. specification no. AP-WCR/WC
Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water 0.33 litre/min with activated carbon filter and softener operating on 230 V single phase A.C. supply with UV fail & filter change indication system.(FOR TDS more than 200)
Supply and erecting of Occupancy sensor light switch having a coverage of min. 6 metre dia at 3.6 metre with site adjustable off timing and instant ON / OFF.
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification No. EA-EP
Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. Specification No. EA-MOBI
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bitumiNous paint in an approved manner with joints required. As per specification No. EA-EP.
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bitumiNous paint in an approved manner with joints required. As per specification No EA-EP.
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
Supplying, erecting & terminating XLPE unarmoured cable 1 core 25 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE unarmoured cable 1 core 50 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CB-LT/CU
Air-termination Rod having height- 1000 mm, to be mounted on side walls. It is of Material- AlMgSi, of Diameter Ø 16 mm , & Complied as per Standard EN 62561-2. Part No. IVANAH EL-IV-1111604
Side Wall Clamp to fix Air Termination Rod on side walls. Material : SS. Complied as per Standard. EN 62561-2. Part No. IVANAH EL-IV-1229001
ATR Clamp cum Connector, to mount on Air Terminator Rod & to connect two conductors on roof. Material : Al , Complied as per Standard EN - 62561-2 Part No. IVANAH EL-IV-1119001
Roof Conductor / Mesh / Down Conductors, of Diameter Ø8 mm, Cross-section- 50 Sq.mm, of Material- AlMgSi & Complied as per Standard EN 62561-2 Part No. IVANAH EL-IV-1210801
Press to Fit type Conductor Holder, 20 mm clearance height. Holding Range 8 -10 mm. Matl.: S.S. Complied as per Standard EN 62561-1. Part No. IVANAH EL-IV-1222001
Extension Pieces, connected by straight connector. Material - Al MgSi, Dimension Ø8 mm having Length app. 395 mm & Complied as per Standard EN 62561-2. Part No. IVANAH EL-IV-1219001
Splicer / Straight Connector which is used to connect the end points of two conductors of size 8-10 mm. Complied as per Standard EN 62561-2. Part No. IVANAH EL-IV-1219002
Multi Clamp / MV clamp, to conduct two conductors, round to round, which are laid acrooss. Material- Steel, with clamping range Rd 8-10 mm, & Complied as per Standard EN 62561-1. Part No. IVANAH EL-IV-1229002
Cross Connector Round to Round type,to conduct two conductors, which are laid acrooss. Also to hold down conductors connected from roof conductors. Material- SS, with clamping range Rd 8-10 mm, & Complied as per Standard EN 62561-1. Part No. IVANAH EL-IV-1329011
Horizontal Ring Conductors, of Diameter Ø8 mm, Cross-section- 50 Sq.mm, of Material- AlMgSi & Complied as per Standard EN 62561-2. Part No. IVANAH EL-IV-1210801
Press to Fit type Conductor Holder, 20 mm clearance height. Holding Range 8 -10 mm. Matl.: S.S. Complied as per Standard EN 62561-1.
Strike Pad is fixed on connected M8 - Stud. The M8 - Stud has been connected by MV Clamp to the concealed horizontal conductor ring of size Dia10 mm SS round bar. This is Complied as per EN 62561-2.
Down Conductors, of Diameter Ø8 mm, Cross-section- 50 Sq.mm, of Material- AlMgSi & Complied as per Standard EN 62561-2
Press to Fit type Conductor Holder, 20 mm clearance height. Holding Range 8 -10 mm. Matl.: S.S. Complied as per Standard EN 62561-1.
Splicer / Straight Connector which is used to connect the end points of two conductors of size 8-10 mm. Complied as per Standard EN 62561-2.
Lightning Flash Counter / Lightning Strike Counter IVANAH make - 6 digit,Working electro mechanically without any power supply. Equipment should count lightning strokes of 0.4KA to 100 KA at the 8/20us standard.
Disconnecting clamp, Round to Flat type, for connecting/disconnecting, suitable for Round Conductor of dia 8 mm & flat size upto 30mm conductor. Material : SS. Complied as per EN 62561-1.
Holder to hold Flat Conductor of Size 25X6 mm, which is a Link to Earth Grid Ring. Material : S.S.
GI Flat Conductor as Link to Earth Grid Ring, of size 25 X 6 , Cross-section- 150 Sq.mm, of Material- GI,. Coating of 80 microns. Complied as per Standard
Cross Connector,Flat to Flat type, to connect two conductors which are laid acrooss. Material- Steel, with clamping range Flat size of 25X6 mm & Flat size of 25X6 mm & Complied as per Standard EN 62561-1.
GI Flat Conductor as Earth Grid Ring, of size 25 X 6 , Cross-section- 150 Sq.mm, of Material- GI,. Coating of 80 microns. Complied as per Standard EN 62561-2.
Copper bonded Earthing Electrode is of low carbon Steel Rod and high tensile strength.The copper bonding is of min 250 microns /copper plating. on the outer surface of Diameter 17.2 mm, having Length- 3 meters. Its Terminal Plate of size 50X5X100 mm length. Complied as per EN 62561-2. Earth Electrode has been tested at CPRI for short time withstand current 18kA rms for 1 Sec. & Peak withstand current 45kA test and found OK. Advance Conductive Backfill Compound, ECO friendly, Non Corrosive, Hydroscopic based, ability to absorb moisture from surrounding Soil, low resistivity Ground Enhancement material 20 Kg Bags, to fill around any Earthing Electrode. Part No. IVANAH EL-IV4000001 Earthing Chamber Cover - Square, Material : Black Colour HDPE, Corrosion resistant, Tested for 5 Tons of Weight. Size - 300 X 300, Ht is 260 mm.
Supplying and erecting three phase 10 to 60 A net meter DLMS compliance of accuracy class 1.0, 3 x 240V, 50 Hz, with backlit LCD display, optical port and RJ 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh,V, I, kW, 6 months history of energy) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
Supplying, installing, testing and commissioning of 100 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 300 Nos.) and Solar ON-GRID Inverter of similar capacity (THD(THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter Installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contractas per Specification no. ESD-RT-ONG
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
FIRE FIGHTING SYSTEM ( HYDRANT & SPRINKLER) Supplying and erecting ABC powder type fire extinguisher as per IS : 15683 of 6 kg capacity with necessary clamp for erection on wall.
Supplying and erecting Carbon Dioxide (Co2) type Fire Extinguisher of 4.5 Kg capacity cartridge type con. to IS: 15683 complete erected with necessary clamp made from 50 mm x 6 mm M.S.flat with nut and bolts grouted in wall complete. CSR 22-23 (13-15-1)
Providing floor mounting stand for keeping 4 Nos. of Fire Buckets 1500 mm in length, 900 mm in height frame made out of 30x30x4 mm. angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint.
Providing round bottom Fire bucket of 9 Litres capacity as per IS: 2546 made out of 24 guage G.I. sheet with extra handle at bottom duly painted white inside and red outside with Fire mark , on provided stand/wall hook .
Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 140 to 120 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 93kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single/multi stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, CSR 22-23(13-1-7)
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2850 LPM at 110 m head driven by 110 HP or suitable HP capacity diesel engine at required working speed suitable for automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete,CSR 22-23 (13-4-3)
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 140 to 110 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 15 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Suitable kW Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP CSR 22-23(13-2-4)
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/B CSR 22-23 (13-3-2).
Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings,
Supplying and erecting G.I.pipe ‘C’class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP CSR 22-23 (13-6-8 )
Supplying and erecting G.I.pipe ‘C’class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP CSR 22-23 ( 13-6-7 )
Providing coating of bitumen paint & 4mm thick wrapping for under ground 150 mm ring main of fire fighting system.CSR 22-23 (13-6-10)
Supplying and erecting G.I.pipe ‘C’class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP CSR 22-23 (13-6-6)
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP CSR 22-23 (13-6-5 )
Supplying and erecting G.I.pipe ‘C’ class ERW 65mm dia with necessary fittings complete as per specification no. FF-PP CSR 22-23 (13-6-4)
Supplying and erecting G.I.pipe ‘C’ class ERW 50mm dia with necessary fittings complete as per specification no. FF-PP CSR 22-23 (13-6-3)
Supplying and erecting ISI mark GI pipe 40mm.dia‘C” class at position with accessories complete. Specification no. CW-PLB/GP.CSR 22-23 (16-5-11)
Supplying and erecting ISI mark GI pipe 32mm.dia‘C” class at position with accessories complete. Specification no. CW-PLB/GP.CSR 22-23 (16-5-10)
Supplying and erecting G.I.pipe ‘C’ class ERW 25mm dia with necessary fittings complete as per specification no. FF-PP CSR 22-23 ( 13-6-2 )
Excavating soft Murum/Soil roadby chiseling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. CSR 22-23 (16-1-7 )
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG CSR 22-23 (13-8-14)
Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS CSR 22-23 (13-8-15)
Supplying and erecting cast iron double flange NRV of size 200 mm dia complete with PN16 pressure rating, as per specification no. FF-VL/NRV (CSR 22-23)-13-7-26
Supplying and erecting cast iron double flange NRV of size 150 mm diacomplete with PN16 pressure rating, as per specification no. FF-VL/NRV (CSR 22-23)-13-7-25
Supplying and erecting cast iron double flange NRV of size 100 mm dia complete with PN16 pressure rating, as per specification no. FF-VL/NRV (CSR 22-23)-13-7-24
Supplying and erecting cast iron double flange NRV of size 80mm dia complete with PN16 pressure rating, as per specification no. FF-VL/NRV (CSR 22-23)-13-7-23
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV (CSR 22-23)-13-7-21
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV (CSR 22-23)-13-7-20
Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV (CSR 22-23)-13-7-18
Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV (CSR 22-23)-13-7-17
Supplying and erecting 200 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV (CSR 22-23)-13-7-16
Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV (CSR 22-23)-13-7-15
Supplying and erecting 80 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV (CSR 22-23)-13-7-14
Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS (CSR 22-23)-13-7-7
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS (CSR 22-23)-13-7-6
Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS (CSR 22-23)-13-7-5
Supplying and erecting stainless steel Double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV (CSR 22-23)-13-7-37
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV (CSR 22-23)-13-7-35
Supplying SS Branch Pipes of 63 mm dia. fitted with 20 mm dia detachable hexagonal multipurpose nozzle as per specification FF-FFA/NZ (CSR 22-23)-13-8-8
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL (CSR 22-23)-13-8-4
Supplying and installing wall mounted swinging Hose Reel Drum fitted with 19 mm dia 30 mtr long high pressure polypropylene (polyhose) pipe fitted with necessary accessories complete as per specification no. FF-FFA/HRD (CSR 22-23)-13-8-2
Supplying and erecting M.S./CRCA cabinet for housing Hydrant valve, hose pipe and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour. (CSR 22-23)-13-8-20
Supplying and erecting 25 mm dia GM Air Release Cock with necessary GI coupling to be fitted on top of air vessel or on wet riser as per specification FF-FFA/ARV. (CSR 22-23)-13-8-13
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT . (CSR 22-23)-13-8-12
Supplying and erecting one no. Brass orifice plate having 6 mm thickness, 160 mm outer dia at every single outlet hydrant valve as per specification No. FF- FFA/OP (CSR 22-23)-13-8-17
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV (CSR 22-23)-13-7-32
Supplying and erecting 15 mm (½") dia. NBCM Body chrome finished (pendent / Upright type) quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction as per specification No. FF-SPR (CSR 22-23)-13-12-1
Providing,fixing,testing & commissioning of 15mm dia quartzoid bulb type sprinkler of rating 68 deg.centigrade with required accessories Horizontal side wall sprinkler (CPWD DSR 2022)-18.21.3
Sprinkler flexible drops stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer,nipple, 2 side brackets,center bracket,stockbar of following sizes complete as required.1500 mm-(CPWD DSR 2022)-18.25.4
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.(CPWD DSR 2022)-18.29
Providing, installation, testing & commissioning of water curtain nozzle 15mm dia nickel chrome plated brass, BSPT, K-factor as per design consideration complete as required.(CPWD DSR 2022)-18.27
supplying,installation,testing & commissioning of deluge valve (to be used for water curtains) UL Isted With wel Pies vate with assembly for DVA with test and alarm, drip and drain valve with water motor gong complete as required. 100 mm dia (CPWD DSR 2022)-18.26.3
Providing, installation, testing & commissioning of electric release trim assembly for deluge wall with two way solelnoid valve, weather proof operation on 24 volts DC supply complete as required (CPWD DSR 2022)-18.28
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).(CSR 22-23)-16-3-5
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU CSR 22-23 ( 7-2-16)
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU CSR 22-23 (13-9-10 )
Supplying, installing, testing and commissioning FR, XLPE armoured cable 12 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU CSR 22-23 ( 13-9-13)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL CSR 22-23 (7-1-18)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU CSR 22-23 (7-2-17)
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riserisprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required 150mm dia (CPWD DSR 2022)-18.24.3
Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes CSR22-23( 3-12-3)
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.CSR 22-23 (13-13-1)
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. CSR 22-23(6-1-19)
Supply, Installation, Testing & Commissioning of Intelligent Addressable type multisensor detector with base, with Microprocessor inbuilt, for use as heat (Fixed + Rate of Rise or individual ) or smoke or combined both with automatic electronic addressing, microprocessor type and must have integrated short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each detector). The detector shall have IP 42 /IP 44 or better protection catagory & ambient temperature -20⁰C to + 60⁰C, the base shal have no electronics only dry contact terminals. The quoted item shall completely comply to the technical specification.Shall be Vds approved according to EN 54-5, 54-7, 54-17, 54-29 or UL& FM approved as per Latest standards
Supply, Installation, Testing & Commissioning of Intelligent Addressable type optical smoke detector with base, with Microprocessor inbuilt with automatic electronic addressing, microprocessor type and must have integrated short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each detector). The detector shall have IP 42 / IP 44 or better protection catagory & ambient temperature -20⁰C to + 60⁰C, the base shal have no electronics only dry contact terminals. The quoted item shall completely comply to the technical specification.Shall be Vds approved according to EN 54-5, 54-7, 54-17, 54-29 or UL& FM approved as per Latest standards
Supply, Installation, Testing & Commissioning of Intelligent Addressable type thermal/heat detector with rate of rise cum fixed temperature thermistor with base, with Microprocessor inbuilt with automatic electronic addressing, microprocessor type and must have integrated short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each detector). The detector shall have IP 44 protection catagory & ambient temperature -20⁰C to + 60⁰C, the base shal have no electronics only dry contact terminals. The quoted item shall completely comply to the technical specification.Shall be Vds approved according to EN 54-5, 54-7, 54-17, 54-29 or UL& FM approved as per Latest standards
Supply, Installation, Testing & Commissioning of Addressable manual call point which is used for manually trigger a fire alarm suitable for interconnecting to the loop technology directly. This must have inbuilt short circuit isolator,. The ambient temperature range shall be -20⁰C to +50⁰C. The quoted item shall completely comply to the technical specification.shall be Vds approved or UL& FM approved as per Latest standards
Supply, Installation, Testing & Commissioning of Addressable Loop Powered multi tone sounder with integrated short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each loop powered sounder) & having operating temperature -10⁰C to + 55⁰C, Volume 89 dB (99 dB) ±3 dB(A)/m at 24 V DC, IP 21 and shall be Vds approved
Supply, Installation, Testing & Commissioning of Addressable loop powered flashing light for visual notification of a fire alarm in interior areas, should have inbuilt fault isolator. The operating Temprature should be -10⁰C to + 55⁰C, Luminous intensity: approx. 1 cd, IP 21 and shall be Vds approved or UL& FM approved as per Latest standards
Supply, Installation, Testing & Commissioning of Active Repeater Panel including a case, membrane keypad, minimum 800 character LCD display with 10 configurable soft buttons and 10 configurable LED's. Repeater panel shall not require separate power supply & battery. Vds approved Panel or UL& FM approved as per Latest standards
Supply, Installation , Testing & Commissioning of Linear Smoke detector consists of a transmitter receiver and reflector which are mounted opposite each other at a distance of between 5 and 120 m.The module must be VDS approved or UL& FM approved as per Latest standards
Supply, Installation , Testing & Commissioning of Vds approved Analogue Addressable Input / Output module with IP66 casing for conventional beam detector with in-built short citcuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each monitor module), it must be VdS approved and as per EN-54 standard. The ambient temperature range shall be -20⁰C to +60⁰C.The quoted item shall completely comply to the technical specification.
Supply, Installation, Testing & Commissioning of 32-bit dual core microprocessor based Fail Safe Intelligent Addressable Fire Alarm Control panel with 12 loop with inbuilt Bluetooth. The FACP should have Capacity of Peer to Peer Networking of Panels, The control panel shall be Vds approved and as per EN-54 standard or UL& FM approved as per Latest standards. The panel should be modular, decentralized, with redundancy in cpu/master control unit, fail safe in loop cards, relay and interface card by means of duplicated electronics . The panel shall consisting with minimum 800 character LCD display with 10 configurable soft buttons and 10 configurable LED's. Panel should be able to record atleast minimum 15000 events history or more. Each loop should be capable to have atleast 250 elements / devices out of which min. 200 nos. shall be detectors. The Panel Shall have on board TCP/IP Lan port to facilate remote operation of the panel.The system should be Vds approved It is possible to Commissioning the System through LAN Network.
Supply, Installation , Testing & Commissioning of Vds approved or UL& FM approved as per Latest standardsAnalogue Addressable Output module with IP66 casing containing one Relay Output with in-built short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each monitor module), it must be VdS approved and as per EN-54 standard. The ambient temperature range shall be -20⁰C to +60⁰C.The quoted item shall completely comply to the technical specification.
Supply, Installation , Testing & Commissioning of Vds approved or UL& FM approved as per Latest standardsAnalogue Addressable Input Module with IP66 casing containing 1 inputs for monitored quering of potential free contacts with in-built short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each monitor module), it must be VdS approved and as per EN-54 standard. The ambient temperature range shall be -20⁰C to +60⁰C.The quoted item shall completely comply to the technical specification.
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU CSR 22-23 ( 13-9-10 )
Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5- 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI CSR 22-23 (13-9-9 )
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. (CPWD DSR 2022)-17.2.17
Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol I.e. supplying communication links between building management system and fire alarm control panel complete as required. (CPWD DSR 2022)-17.2.18
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. (CPWD DSR 2022)-17.2.19
Design, supply, installation, testing and commissioning of Windows based Central Monitoring & Control Software with 8 Licenses and expandable to 32, shall be capable to perform paging and message playing to all zones of devices over LAN. Unicast/multicast, Routing, Message Playing, Scheduler, Text to speech and volume control, shall be capable to monitor all the system components, Monitoring device status such as Offline/online or line-occupied/line available to Support TCP, UDP, SIP, RTP and IGMP protocol. The Server shall have user friendly to configuration and flexibility in button design. inclusive of required software & license.
Supply, installation, testing and commissioning of Intel Core i5 Quad Core @ 3.3 GHz or Latest, 16GB dual channel DDR3 1333/1600,Graphics NVIDIA (2 GB dedicated) With DVI/HMI output with 2TB 7.5K rpm SATA hard disk, PS/2 / USB Compatible, Dual Gigabit Ethernet, power supply provisions Cost should be With Life time license for Windows 8 enterprise/professional or latest software compatible MacAfee /Symantec Anti virus, with 24 Inch LED Display Monitor & All other related software such MS office with liscesenced. The required operation & PA software etc. & Workstation should be FCC & UL listed.
Supply, Installation, Testing & Commissioning of controller unit which is programmable with the software on each specific system configuration, with automatic and permanent monitoring of the system controller and the system components according to EN 50849, BS5839, NEN2575 and EN54-16. Programmable over network interface with code protected access to the processing unit and other components in the system. (modules , amplifiers and paging stations). It should have following features • Monitored according to standard EN 54-16 • 4 Channel Audio Player • 8 programmable buttons / LEDs • DSP for all analog and digital inputs / outputs • 2 MC LINK inputs for serial microphone consoles • 4 analog inputs -60 to 0 dBu • 2 analog outputs 0 dBu • 8 digtial monitored inputs • 4 digital potential-free change-over contacts • APS network functions (optional software package ) • Web server for operating and display units (optional software package) • Embedded hardware firewall to separate VA and PA functions • Various interfaces (optional software package) for connection to control centres and building management systems
Supply, installation, testing and commissioning of Digital Zone monitoring controller according to EN 54-16 It should contain line monitoring with DSP technology for uninterrupted, permanent (even with music mode) automatic monitoring of up to 32 speaker zones for short circuit, open circuit, short to ground and impedance change, by means of High-precision error detection with DSP technology by load measurement, measurement of the phase shift between current and voltage. LED indication on front-side per speaker line. It should have rotary knob and Integrated LCD display for menu-guided operation Like -deactivation of zones, Lists detailed error analysis , Automatic calibration of each individual zone, Individual adjustment of the measuring tolerance for each individual zone . Further it must have features: - Fault memory in an error list in accordance with EN 54-16 - Automatic isolation of the defective speaker line in short-circuit - Recognition of the re- functioning speaker line without a device reset - Permanent monitoring of each line without additional modules (eg end-of -line) - No interruption of the line for voice announcements or background music with high-quality DSP technology. CE Conformity: EN 54-16 Electromagnetic. Immunity: to EN 55024 / EN 301 489 Emission standard: according to EN 55022 / EN 300220-1
Supply, installation, testing and commissioning of Digital Class-D power amplifier 500 watts, 100 volts Digital, fully monitored, convection cooled power amplifier, with a continuous power of 100 watts especially according to EN 54-16. It should have a micro-controller including digital disaster management and emergency charging electronics for standards-compliant, optional redundant supply of emergency battery power unit. It should also have programmable 5 x 4 matrix, the 4 internal and the external digital, analog AF - bus can be set system-specific in the software on each amplifier channel. It should have protection circuits against overload, short circuit, open circuit, overvoltage, power failure, battery failure, data communications failure, thermal overload. Also, it should be activatable as a standby mode. Features: Electronically balanced audio input via XLR jacks Output power: 100W (Maximum) : 100W RMS Controlling: Microprocessor Power supply: 230 VAC + / - 10 % Frequency response: 50 Hz to 20 kHz (-3 dB) Emergency power supply: 48 VDC Signal to noise ratio:> 94 dB CE Conformity: EN 54 -16: 2008 Electromagnetic. Immunity: to EN 55024 / EN 301 489 Emission standard: according to EN 55022 / EN 300220-1
Supply, installation, testing and commissioning of Digital Class-D power amplifier 4 x 250 watts, 100 volts Digital, fully monitored, convection cooled power amplifier, with a continuous power of 4 x 250 watts especially according to EN 54-16. It should have a micro-controller including digital disaster management and emergency charging electronics for standards-compliant, optional redundant supply of emergency battery power unit. It should also have programmable 6 x 4 matrix, the 4 internal and the 2 external digital, analog AF - bus can be set system-specific in the software on each amplifier channel. It should have protection circuits against overload, short circuit, open circuit, overvoltage, power failure, battery failure, data communications failure, thermal overload. Also, it should be activatable as a standby mode Features: 4 Electronically balanced audio input via XLR jacks Output power: 4 x 250W (Maximum) : 4 x 200W RMS Controlling: DSP Microprocessor Power supply: 230 VAC + / - 10 % Frequency response: 50 Hz to 20 kHz (-3 dB) Emergency power supply: 48 VDC Signal to noise ratio:> 94 dB CE Conformity: EN 54 -16: 2008 Electromagnetic. Immunity: to EN 55024 / EN 301 489 Emission standard: according to EN 55022 / EN 300220-1
Supply, installation, testing and commissioning of Digital Class-D power amplifier 2 x 250 watts, 100 volts Digital, fully monitored, convection cooled power amplifier, with a continuous power of 2 x 250 watts especially according to EN 54-16. It should have a micro-controller including digital disaster management and emergency charging electronics for standards-compliant, optional redundant supply of emergency battery power unit. It should also have programmable 6 x 4 matrix, the 4 internal and the external digital, analog AF - bus can be set system-specific in the software on each amplifier channel. It should have protection circuits against overload, short circuit, open circuit, overvoltage, power failure, battery failure, data communications failure, thermal overload. Also, it should be activatable as a standby mode Features: 2 Electronically balanced audio input via XLR jacks Output power: 2 x 250W RMS : 2 x 200W RMS Controlling: Microprocessor Power supply: 230 VAC + / - 10 % Frequency response: 50 Hz to 20 kHz (-3 dB) Emergency power supply: 48 VDC Signal to noise ratio:> 94 dB CE Conformity: EN 54 -16: 2008 Electromagnetic. Immunity: to EN 55024 / EN 301 489 Emission standard: according to EN 55022 / EN 300220-1
Supply, installation, testing and commissioning of EN 54-24 certified 6W rectangular wall mounted speaker with maximum SPL of 103 db @6W/1m and magnet 10'500 Gs. It must have sensitivity of Sensitivity (1 W/ 1 m) 95.7 dB. The speaker should have 1.5W/ 3W/ 6W tapping. It should be of EV-Version with ceramic terminal and thermal fuse and with IP 44 protection. The speaker must be with metal enclosure.
Supply, installation, testing and commissioning of EN 54-24 certified 6W Ceiling speaker with maximum SPL of 101.6 db @6W/1m and magnet 4000 Gs. It must have sensitivity of Sensitivity (1 W/ 1 m) 93.8 dB. The speaker should have 1.5W/3W/6W tapping. It should be of EV-Version with ceramic terminal and thermal fuse and with IP 44 protection. The speaker must be with metal dome.
Supply, installation, testing and commissioning of EN 54-24 certified 20W Horn 360 deg speaker with maximum SPL of 118.8 db @20W/1m. It must have sensitivity of Sensitivity (1 W/ 1 m) 105.8 dB. The speaker should have 2.5W / 5W / 10W / 20W tapping. It should be of EV-Version with IP 65 protection. The speaker must be with metal enclosure canopy.
Supply, installation, testing and commissioning of 40W Horn 360 deg speaker with maximum SPL of 128.5 db @40W/1m. It must have sensitivity of Sensitivity (1 W/ 1 m) 112.5 dB. The speaker should have 5W / 10W / 20W / 30W / 40W tapping. It should be of IP 66 protection.
Supply, installation, testing and commissioning of EN 54-24 certified 15W 2 way Ceiling speaker with maximum SPL of 106 db @15W/1m. It must have sensitivity of Sensitivity (1 W/ 1 m) 94.5 dB. It should be of EV-Version with ceramic terminal and thermal fuse and with IP 44 protection. The speaker must be with metal dome.
Supply, installation, testing and commissioning of EN 54-24 certified 12 W double sided design Sound projector speaker with maximum SPL of 88 db @1xW/1m. It must have sensitivity of (1 W/ 4 m) 76 dB. The speaker should have 12 / 6 / 3 W tapping. It should be of EV-Version with ceramic terminal and thermal fuse and with IP 65 protection. The speaker must be with metel enclosure.
Supply, Installation, Testing & Commissioning of modular type 36W volume control units with override mechanism suitable including front plate and anodised GI box in concealed manner of adequate sizes, including all fixing accessories.
Supply & fixing of Relay contact with standard connectivity accessories & hardware
Supply & fixing of warning light with relay contactor
Supply and wiring of 2C - 1 sq. mm. FRLS insulated twisted pair multistranded copper conductor armoured cable in existing PVC/ GI conduit or direct on ceiling surface with clamp, complete as required.
Supply and wiring of 4C - 1.5 sq. mm. FRLS insulated multistranded copper conductor armoured cable in existing PVC/ GI conduit or direct on ceiling surface with clamp, complete as required.
Supplying and fixing 42 U floor mount server Rack (Dimension-DxW – 800x1000 x2070mm) as per specification No. WG-NAS/RAK
LIFT WORK SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with Rated capacity :- 20 Passenger/1360Kg Floors :- B+ G+12 floor (14 Stops/14 Landings) Travel :- 55 mtrs Appx. Location of Lift Machine:- MR/MRL Rated speed :- 1.5mps VS Car/Landing door clear opening of 1200 mm wide x 2000 mm Clear Car size of 1300 mm wide x 2600 mm deep x 2250mm high Lift shaft available having clear size of 2400 mm wide x 3000 mm deep, 1600 mm Pit depth,4800 mm Overhead. Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. ARD complete with necessary SMF VRLA batteries. Fireman controller having fireman switch at fire Landing. CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. "Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. Lift shaft available having clear size of 2350 mm wide x 3000 mm deep, 1600 mm Pit depth, aprox.4500 mm Overhead. (Lifts with Triplex Control) Notes:- 1. General: - Job includes entire procedure of obtaining all necessary erection permissions & ""License to Work the Lift"" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. 2. Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule. Amount as given in maintenance schedule will be deducted and kept aside as Security deposit for 3 years AMC period. "
SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with Rated capacity :- 20 Passenger/1360Kg Floors :- G+12 floor (13 Stops/13 Landings) Travel :- 50 mtrs Appx. Location of Lift Machine:- MR/MRL Rated speed :- 1.5mps VS Car/Landing door clear opening of 1200 mm wide x 2000 mm Clear Car size of 1300 mm wide x 2600 mm deep x 2250mm high Lift shaft available having clear size of 2400 mm wide x 3000 mm deep, 1600 mm Pit depth,4800 mm Overhead. Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. ARD complete with necessary SMF VRLA batteries. Fireman controller having fireman switch at fire Landing. CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. "Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. Lift shaft available having clear size of 2350 mm wide x 3000 mm deep, 1600 mm Pit depth, aprox.4500 mm Overhead. (Lifts with Triplex Control) Notes:- 1. General: - Job includes entire procedure of obtaining all necessary erection permissions & ""License to Work the Lift"" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. 2. Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule. Amount as given in maintenance schedule will be deducted and kept aside as Security deposit for 3 years AMC period. "
SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete.
SITC of Triplex Lift control system for three nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete.
HVAC SYSTEM Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 400mm dia. (75 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 350mm dia. (75 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 300mm dia. (75 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 250mm dia. (75 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 200mm dia. (75 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 150mm dia. (75 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 125mm dia. (50 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 100 mm dia. (50 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 80 mm dia. (50 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 65 mm dia. (50 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.50 mm dia. (50 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above 40 mm dia. (50 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.32 mm dia. (50 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type, grade 1 roofing feltstrip(as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 25 mm dia. (50 mm thick insulation)
Supply,fixing,testing and commissioning of butterfly valve(manual) with CI body SS Disc,Nitrile Rubber seal & O Ring PN 16 Pressure rating for chilled water/hot water circulation as specified. 150 mm Dia
Supply,fixing,testing and commissioning of butterfly valve(manual) with CI body SS Disc,Nitrile Rubber seal & O Ring PN 16 Pressure rating for chilled water/hot water circulation as specified. 125 mm Dia
Supply,fixing,testing and commissioning of butterfly valve(manual) with CI body SS Disc,Nitrile Rubber seal & O Ring PN 16 Pressure rating for chilled water/hot water circulation as specified. 100 mm Dia
Supply,fixing,testing and commissioning of butterfly valve(manual) with CI body SS Disc,Nitrile Rubber seal & O Ring PN 16 Pressure rating for chilled water/hot water circulation as specified. 80 mm Dia
Supply,fixing,testing and commissioning of butterfly valve(manual) with CI body SS Disc,Nitrile Rubber seal & O Ring PN 16 Pressure rating for chilled water/hot water circulation as specified. 65 mm Dia
Supply,fixing,testing and commissioning of butterfly valve(manual) with CI body SS Disc,Nitrile Rubber seal & O Ring PN 16 Pressure rating for chilled water/hot water circulation as specified. 50 mm Dia
Supply,fixing,testing and commissioning of butterfly valve(manual) with CI body SS Disc,Nitrile Rubber seal & O Ring PN 16 Pressure rating for chilled water/hot water circulation as specified. 40 mm Dia
Supply,fixing,testing and commissioning of Y- Strainer of Ductile Ci Body flanged ends with SS strainer for chilled/ hot water circulation including insulation as specified. 80 mm Dia
Supply,fixing,testing and commissioning of Y- Strainer of Ductile Ci Body flanged ends with SS strainer for chilled/ hot water circulation including insulation as specified. 65 mm Dia
Supply,fixing,testing and commissioning of Y- Strainer of Ductile Ci Body flanged ends with SS strainer for chilled/ hot water circulation including insulation as specified. 50 mm Dia
Supply,fixing,testing and commissioning of Y- Strainer of Ductile Ci Body flanged ends with SS strainer for chilled/ hot water circulation including insulation as specified. 40 mm Dia
Supplying and erecting GI pipe 50 mm dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
Supplying and erecting GI pipe 40 mm dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
Supplying and erecting GI pipe 32 mm dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
Supplying and erecting GI pipe 25 mmdia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 28 mm for solar water heater/AC system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 42 mm for solar water heater/AC system.
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.80 mm Dia
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.65 mm Dia
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 50 mm Dia
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 40 mm Dia
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.32 mm Dia
Supplying and erecting GI sheet 0.6 mm (24 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting GI sheet 0.8 mm (22 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting GI sheet 1 mm (20 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting GI sheet 1.25 mm (18 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supply,installation ,testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets,nuts,bolts, screw linkages,flanges etc as per specifications
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control Dampers as per specifications
Supplying & fixing of powder coats extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.(
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC2017.
Providing and applying of acoustic insulation for air ducts with 25mm thick, 48 kg/cu.m fiber glass faced with RP tissue and covered with 26 SWG perforated aluminium sheets complete.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
CCTV AND LAN SYSTEM Supply, installation, testing & commissioning of IP Fixed Dome camera (Indoor) with 1/2.8" CCD/CMOS, 5MP, 3.5-10 mm motorized varifocal, P/DC- Iris lens Progressive/De-interlace, High Definition resolution (2592 x 1944), min. Quad streaming, Shutter speed - 1/1,00,000/sec, First & Second Stream should be 30 FPS @ 1920X1080, H.264/H.265 & JMPEG compression support, 0.1 lux @ Built-in IR illuminators, effective up to 30 meters, Motion detection, Tamper detection,3D DNR, Wide dynamic Range, PoE power input, 40 Mtr IR AWB, AGC, BLC, 1/1 Alarm in/out, 1/1 audio in/out, Should have a compulsory Reset button audio -In & Out Port, RJ 45 Port, SD card 256 GB, 40 Mtr IR Range, Metal Body, Support ONVIF(S,G,T), PoE, CE, FCC ,IP67, NDAA, NEMA-4X, STQC certified. No GB/T 28181, Cybersecurity certification required (NDAA/UL/GDPR/NIST/TPM/ISO 27032/Indian Govt.). All Required Mounting Accessories and Hardware should be included.
Supply, installation, testing & commissioning of Outdoor IP Bullet camera with 1/2.8" CMOS or better, Progressive Scan, 5MP, Day/Night, 3.5 to 10 mm motorised zoom lens with Autofocus,Remote Focus,Shutter speed - 1/1,00,000/sec, Support H.264/H.265 & MJPEG, First & Secound Stream should be 30 FPS @ 2592X1944, Quad streaming, Motion detection, video tampering, Tamper detection, Digital WDR 120 dB, Day/ Night (ICR), 3D DNR, AWB, AGC, BLC, 1/1 Alarm in/out, 1/1 audio in/out, Should have a compulsory Reset button audio -In & Out Port, RJ 45 Port, 60 Mtr IR Range,SD card 256 GB, Support ONVIF, IP67,IK10,PoE, CE, FCC, NDAA, NEMA-4X, STQC certified. No GB/T 28181, Cybersecurity certification required (NDAA/UL/GDPR/NIST/TPM/ISO 27032/Indian Govt.). All Required Mouting Accessories and Hardware should be incluided.
Supply, installation, testing & commissioning of Outdoor PTZ IP Camera of 4K, 8 MP PTZ DOME STARLIGHT CAMERA; vandal-proof IP66; integral 1/1.8" day/night camera with 6.5-230 mm 35X zoom lens; 1312 ft (400 m) Range, IR; speed dry; 71 W max, requires 90 W power injector; NDAA/GSA/TAA/HTQC compliant. All Required Mounting Accessories and Hardware should be included.
Supply, installation, testing & commissioning of Outdoor PTZ IP Camera of 5 MP PTZ DOME STARLIGHT CAMERA; vandal-proof IP66; integral 1/2.8" day/night camera with 4.25-170 mm 40X zoom lens; up to 250m Range IR; speed dry; 71 W max, requires 90 W power injector (VPOE-INJ-90BT-A/equivalent); NDAA/GSA/TAA compliant. All Required Mouting Accessories and Hardware should be incluided.
Supply, installation, testing & commissioning of WALL MOUNT; medium; for use with Roughneck multi-sensor, domes and PTZ cameras. All Required Mouting Accessories and Hardware should be incluided.
Supply, installation, testing & commissioning of Controller, IP system keyboard with LED Display to control PTZ. It should be as per Technical Specification.
Supply, installation, testing & commissioning of 64 Channel Network Video Recorder (NVR) with neccessary monitoring software - 19" rack mounted, Network Video Recorder 64 Channel Connect Up to 64 IP Cameras,HDMI1/ VGA1 and HDMI2/ VGA2 outputs provided, NVR Supports two HDMI port one with 4K resolution and other with 1920x1080p, atleast one VGA output with output upto 1920 × 1080, Support H.265, H.264, MJPEG, Supports RAID0/ RAID1/ RAID5/ RAID6 , Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces and capacity of each HDD upto 8TB, RS-232; RS-485, Alarm I/O 16/4, atleast 2 RJ-45 10 /100 Mbps Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. All Required Mouting Accessories and Hardware should be incluided.
Supply, installation, testing & commissioning of 10TB SURVELLAINCE Hard Disk (Minimum 30 days with 25/30 FPS, recording- motion Based, H.265 Compression Technique)
Supply, installation, testing & commissioning of Application server for VMS: 1U Server / Tower, Processor: Intel Xeon E-2400 series processor with up to 8 cores, RAM: 32 GB DDR5 RAM, OS Storage: OS DRIVE: 2X 480GB M.2 SSD/NVMe BOSS (RAID 1), Network Port: 2 x 1GbE RJ45, Power Supply: Dual, hot-swappable, redundant power supply units (PSUs)., OS: Microsoft Windows 11 loT LTSC, HDD: 6Gbps SATA 7200RPM 3.5in, Storage: 50 TB Usable. All Required Mouting Accessories and Hardware should be incluided.
Supply, installation, testing & commissioning of Remote Viewing Workstation for CCTV : Intel i7 Processor, min 32 GB high speed DDR 4 RAM, 1TB SSD,4TB HDD Pre Loaded with Windows 11 or Higher OS as per OEM recomendation, Firewall and Antivirus, DVD RQ and with Additional Graphics Card with 8GB Video RAM and Dual Monitor Display Output on HDMI/ VGA Interface, with PC Speakers, wireless mouse & keyboard etc.& Workstation shall operate for 24x7 operation. All Required Mouting Accessories and Hardware should be incluided.
Supply, installation, testing & commissioning of Main Viewing Screens for above mentioned Remote Viewing Work station large wall mount LED screens, no less than 50'' with HDMI, PC inputs. Screen should be suitable for 24X 7 operation.It shall come with remote control and shall have various picture mode options for data representation with all necessary Fixing accessiories for viewing, The Monitor should be FCC & UL listed All Required Mouting Accessories and Hardware should be incluided.
Supply, installation, testing & commissioning of Video Management software system & required no. of Channel License per camera. STQC certified, ONVIF S,G,T.
Supply, installation, testing & commissioning of adjustable wall Mounting MS stands for outdoor cameras,made out of 5mm thick, 80mm dia pipe with zinc chromite primer & powder coating of suitable shade. All Required Mouting Accessories and Hardware should be incluided.
Supply, installation, testing & commissioning of Weather Proof Junction Box for Camera End with required all Mouting Accessories and Hardware etc. All Required Mouting Accessories and Hardware should be incluided.
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC
Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected along with 1 no of tool-less Information Outlet (Ethernet) flush type in provided modular box as per specification no.WG-NAS/IO (Item no.1-6-26 Rs.124.00 + 1-12-2 Rs.506.00 = Rs.630.00)
Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module complete duly erected along with 2 no of tool-less Information Outlet (Ethernet) flush type in provided modular box as per specification no.WG-NAS/IO (Item no.1-6-27 Rs.128.00 + 1-12-2 Rs.506.00 x 2 nos = Rs.1140.00)
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module complete duly erected along with 4 nos of tool-less Information Outlet (Ethernet) flush type in provided modular box as per specification no.WG-NAS/IO) (Item no.1-6-29 Rs.172.00 + 1-14-2 Rs.448.00 x 3 nos = Rs.1748.00)
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module complete duly erected along with 4 nos of tool-less Information Outlet (Ethernet) flush type in provided modular box as per specification no.WG-NAS/IO) (Item no.1-6-29 Rs.172.00 + 1-14-2 Rs.448.00 x 4 nos = Rs.2196.00)
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and fixing Cat-6 24 port Patch panel with Tool-less keystone jacks in provided U Rack complele as per specification no WG-NAS/PP
Suppying and fixing 1 meter length, UTP patch cord of Cat 6 type in position as per specificationNo WG-COC/PC
Supplying and fixing 2 m UTP patch cord of cat 6 type in position as per specification No. WG-COC/PC
Supplying, Installing & Testing UTP Connector (RJ-45) as per specification No WG,NAS/UTPC
Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, with core dia 50/125 Lm (OM4) suitable for 1 gbps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC
Supplying and erecting LSZH armoured multimode optical fibre cable with 24 fibres, core dia 50/125 μm (OM3), suitable up to 10 GBPS ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC
Supplying and fixing Rack mounted type 12 Ports, Light guide unloaded Interconnect Unit with adapter Panel for termination of Optical fibre cables on wall/ provided U Rack complete as per specification no. WG-NAS/ LIU
Supplying and fixing 24 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fibre cables in provided U rack complete as per specification no. WG-NAS/ LIU
Supplying and fixing SC/LC type multimode duplex adapter to couple two connectors between OFC & Fibre switch/Fibre module as per specification no. WG-NAS/MMA
Supplying and plugging 3 m fibre patch cord LC-SC MM (50) OM4 LSZH duplex complete as per specification no. WG-COC/FPC
Supplying and plugging 3 m fibre patch cord LC-LC MM (50) OM4 LSZH duplex complete as per specification no. WG-COC/FPC
Supplying and fixing SC/LC type multimode pigtails (OM4) as per specification complete. WG-NAS/LIU2
Supplying & erecting Jelly filled armoured telephone cable 20 pair with 0.5 mm dia. laid in provided trench as per specification No. WGTW
Supplying & erecting Jelly filled armoured telephone cable 50 pair with 0.5 mm dia. laid in provided trench as per specification No. WGTW
Supplying & erecting Jelly filled armoured telephone cable 100 pair with 0.5 mm dia. laid in provided trench as per specification No. WGTW
Supplying & erecting Jumper wire with 0.5 mm dia as per specification No. WG-TW
Supplying, erecting & commissioning 50 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying, erecting & commissioning MDF Box 200x200 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying, erecting & commissioning MDF Box 400x400 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying, erecting & commissioning MDF Box 800x800 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW
Supplying and erecting PVC box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification No: GMA/ BOX .
Supplying and erecting PVC box trunking of size 50x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX.
Concealing of provided G.I. pipe/H.G. screwed conduit/PVC pipe in wall/floor/false ceiling complete as per specification No:WG-PW/CW
Supplying & erecting HMS P.V.C. conduit 25 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-ncapping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and fixing 42U floor mount server rack (Dimension-DxWxH – 800x600x1866 mm) as per specification No. WG-NAS/RAK
Supplying and fixing 42 U floor mount server Rack (Dimension-DxW – 800x1000 x2070mm) as per specification No. WG-NAS/RAK
Supplying and fixing 15U wall mount rack (Dimension-DxWxH – 500x600x767 mm) as per specification No. WG-NAS/RAK
Supplying and fixing 12U wall mount rack (Dimension-DxWxH – 500x600x635 mm) as per specification No. WG-NAS/RAK
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK
Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete.
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS.
Supplying, fixing, and configuring 20 SFP ports + 4 Combo SFP 10/100/1000 Base-T erected in provided rack complete.
Supplying, fixing, and configuring 20 Ports+4G Combo, Managed Layer 2, POE Switch erected in provided rack complete.
Supplying, fixing, and configuring 1-port mini-GBIC SX MM fibre transceiver (up to 550m, support 3.3V power) erected in provided rack complete
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
WATER SUPPLY & SANITARY WORKS Providing and fixing sink cock with regular swinging spout (Wall / floor Mounted Model) with wall flange having flow rate up to 6.0 Litr/Minute of Jaquar/Cera/Hindware/Perryware or equivalent make incluidng other necessary fitting, etc. complete as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
Providing and fixing Hand shower (health faucet) with 8mm dia. 1m long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in Charge.
Providing and fixing divertor with overhead shower,shower arm,spout,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)
Providing and fixing wall mixer with overhead shower,shower arm,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.
Providing and fixing Table top white wash basin of size 120x635x405mm rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge.
Providing and fixing white Opal series European type wall-hung, of size 400 mm x 370 mm x 575mm with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.
Providing and fixing Orissa Pan of size 580x445x260 mm with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100mm dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge.
Providing and fixing C.P. a 2-Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
Providing and fixing white glazed urinal of size 710x460x300mm with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete.
Providing and fixing 15mm di ameter PVC Aqua kraft type of approved makesuper jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc complete
Providing and fixing wall-hung white wash basin of size 470x575x190mm of approved make half pedestal, pillar cock, C.P. Angular stop cock, long thread continental including S.S. bottle trap of having necessary pipe connections up to the outside face of the wall.etc complete.
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.
Providing and fixing partition with kadappa stone of all sizes and 25 mm thick polished on both side and edges to original including fixing in position in cement mortor 1:4 curing polishing, cleaning etc complete.
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete.
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm including coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.
Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providing T.W.gutties etc. complete
Providing and fixing on walls/ ceiling/ floor 15mm dia.CPVC pipe with necessary fittings,remaking good the demolished portion etc.complete.Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 20mm dia.CPVC pipe with necessary fittings,remaking good the demolished portion etc.complete.Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 25mm dia.CPVC pipe with necessary fittings,remaking good the demolished portion etc.complete.Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 32mm dia.CPVC pipe with necessary fittings,remaking good the demolished portion etc.complete.Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 40mm dia.CPVC pipe with necessary fittings,remaking good the demolished portion etc.complete.Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 50 mm dia.CPVC pipe with necessary fittings,remaking good the demolished portion etc.complete.Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Supplying and erecting ISI mark GI pipe 65mm.dia‘C”class position with accessories complete. Specification no. CW-PLB/GP-(CSR 22-23)
Supplying and erecting ISI mark GI pipe 80 mm.dia‘C”class position with accessories complete. Specification no. CW-PLB/GP (CSR 22-23)
Supplying and erecting ISI mark GI pipe 100mm.dia‘C”class position with accessories complete. Specification no. CW-PLB/GP (CSR 22-23)
Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete
Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete
Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete
Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete
Ball cock for 15mm dia.
Ball cock for 25mm dia.
Ball cock for 32 mm dia.
Ball cock for 40 mm dia.
Providing and fixing 50mm diameter water meter with non-return valve including strainer,sockets/ union nut and including water meter box making locking arrangement and lock. [without chamber]
Providing and fixing 100mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock.[Without chamber].
Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV (CSR 22-23)
Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV (CSR 22-23)
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV (CSR 22-23)
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV (CSR 22-23)
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV .(CSR 22-23)
Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV .(CSR 22-23)
Supplying and erecting non return valve 65 mm dia in position made of gun metal complete.(CSR 22-23)
Supplying and erecting non return valve 80 mm dia in position made of gun metal complete.(CSR 22-23)
Supplying and erecting non return valve 100 mm dia in position made of gun metal complete(CSR 22-23)
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete.
Providing and making ISI Mark ferrule connection of 25mm dia.to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete.
Providing and making ISI Mark ferrule connection of 50mm dia.to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete.
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV.(CSR 22-23)
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS .(CSR 22-23)
Supplying and erecting 12/16 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 1.7 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPV.(CSR 22-23)
Supplying and erecting 16/20 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 2.0 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPV.(CSR 22-23)
Supplying and erecting 20/25 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 2.6 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPV.(CSR 22-23)
Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPV.(CSR 22-23)
Supplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPV.(CSR 22-23)
Supplying and erecting 40/50 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPV.(CSR 22-23)
Providing and fixing on walls /ceiling/ floor 40mmdia. uPVC pipe with necessary fittings,remaking good the demolished portion etc.complete.Including removing existing pipe line if necessary and conveying and stacking the samein PWD chowky or as directed etc. complete.
Providing and laying cast iron pipes of B class of 150mm diameter with sockets and spiget ends/ flanges and cast centrifugally/ vertically including specials, laying pipes and back filling the trench complete including excavation.
Providing and making flanged connection for the 150mm diameter cast iron pipe line including painting rubber insertion, nuts and bolts etc. complete.
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc.complete
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc.complete
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, including fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. Complete.
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, including fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. Complete.
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogram with frame etc complete.
Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover medium duty 140 Kilogram. etc complete
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm With R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight with 75 mm thick R.C.C. cover medium duty 140Kilogram etc. Complete.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and constructing Ductile Iron circular manhole 45 cm dia. At top 90 cm at bottom up to 1.80 meter to 2.70 meter depth including excavation, laying 1:4:8 cement concrete bedding 15 cm thick burnt brick mansonry with 1:1 cement mortar plaster 25 mm thick inside and outside 20 mm (1:3) ductile iron heavy type cover with ring 125Kilogramin weight. High strength. More life and Durability, Good Antiskid Grip, Suitable to heavy theatric loading, Light weight casting after cost benefits for Transportation Refilling etc. as per requirement. with prior approval of concerned Superitending Engineer
C.I. Steps for Manhole
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.(CSR 22-23)
Providing and fixing 8 cm rigid PVC Nahani trap including PVC grating ,bend, connecting piece of UPVC pipe up to the outside face of wall ,making the good damaged surfaceandtestingetc.complete(Prior approval of sample and brandbyEx.Engr is necessary before use).
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend, connecting piece of UPVC pipe up to the outside face of wall ,making the good damaged surfaceandtestingetc.complete(Prior approval of sample and brandbyEx. Engr. is necessary before use)
Providing and fixing 10 cm PVC nahani trap with grating etc. complete.
Providing and fixing Hot dipped Galvanized Iron Puddle flange, both side flanged ends, to be inserted in RCC Tank as per Consultants drawing, with required welding with reinforcement steel, for all leads and lifts, testing etc. 50mm pipe
Providing and fixing Hot dipped Galvanized Iron Puddle flange, both side flanged ends, to be inserted in RCC Tank as per Consultants drawing, with required welding with reinforcement steel, for all leads and lifts, testing etc. 80mm pipe
Providing and fixing Hot dipped Galvanized Iron Puddle flange, both side flanged ends, to be inserted in RCC Tank as per Consultants drawing, with required welding with reinforcement steel, for all leads and lifts, testing etc. 150mm pipe
Providing and fixing Hot dipped Galvanized Iron Puddle flange, both side flanged ends, to be inserted in RCC Tank as per Consultants drawing, with required welding with reinforcement steel, for all leads and lifts, testing etc. 200mm pipe
Chemical Bolt M8 Packet of 20
Liquid Limit & Plastic Limit for Plinth Filling
Standard Consistancy, Fineness, Specific Gravity, Setting Time (Initial and Final), Compressive Strength, Soundness Test for Cement
Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Artificial Sand
Sieve Analysis Test for Metal below 40 milimetre
Water Absorption, Specific Gravity, Impact Value, Crushing Value Test for Metal below 40 milimetre
Compressive Strength of Cement Concrete Cube
Concrete Mix Design (with all tests on basic materials) for Grade M-40
Concrete Mix Design (with all tests on basic materials) for Grade M-20
Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Sand
Crushing Value / Compressive Strength, Water Absorption, Specific Gravity Test for Stone / Rubble
Tensile Strength, Percent Elongation, Yield Stress, Weight per Metre, Bend /Rebend Test, Proof Stress (Steel Bar upto 16 milimetre)
Tensile Strength, Percent Elongation, Yield Stress, Weight per Metre, Bend /Rebend Test, Proof Stress (Steel Bar above 16 milimetre)
Water Absorption, Compressive Strength, Efflorescence Test for Burnt Bricks
Compressive Strength of Cement Mortar
Density, Moisture Content for Wood
Thickness, Mass per Running Metre of Aluminium Section
Water Absorption, Modulus of Rupture Test for Ceramic / Vitrified Tiles
Sieve Analysis Test for Hard Murrm
Liquid Limit and Plastic Limit for Hard murum
Granular Sub-Base Mix Design
Compaction Test (Proctor Density) for earth work
Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Metal below 40 milimetre
Concrete Mix Design (with all tests on basic materials) for Grade M-35
Compressive Strength, Water Absorption Test for Paving Blocks - 80 milimetre thick, 300 Kilogram per Square Centimetre Strength
Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Sand
(A) Royalty charges (Filling in plinth & floors with contractors)
(B) Royalty charges (Supplying hard murum/ kankar at the road site)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Tendernotice_1.pdf
PDF • 0.46 MB
RFP.pdf
Tender Documents • 12.10 MB
BasementPlan.pdf
Tender Documents • 0.34 MB
GroundFloorPlan.pdf
Tender Documents • 1.80 MB
SecondFloorPlan.pdf
Tender Documents • 1.69 MB
FirstFloorPlan.pdf
Tender Documents • 2.07 MB
BOQ_2170121.xls
BOQ • 1.20 MB
SitePlan.pdf
Tender Documents • 1.19 MB
8thFloorPlan.pdf
Tender Documents • 1.21 MB
10th11thFloorPlan.pdf
Tender Documents • 1.48 MB
7thFloorPlan.pdf
Tender Documents • 1.39 MB
Typical4th5th6thFloorPlan.pdf
Tender Documents • 1.41 MB
12thFloorPlan.pdf
Tender Documents • 2.08 MB
NinthFloorPlan.pdf
Tender Documents • 1.23 MB
SectionBB.pdf
Tender Documents • 0.27 MB
ElevationSectionAA.pdf
Tender Documents • 0.52 MB
ThirdFloorPlan.pdf
Tender Documents • 1.11 MB
CSD.pdf
Tender Documents • 1.03 MB
19ElectricalSLD.pdf
Tender Documents • 4.08 MB
FrontElevation.pdf
Tender Documents • 0.58 MB
Download all tender documents and submit your bid