Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | ₹1.0 Cr Quoted ₹1.1 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.1 Cr+₹2.5 L (2.32%)Rejected-Finance FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | ₹1.1 Cr+₹2.5 L (2.32%) | L2 | Rejected-Finance Other Than Being Lowest |
| 3 | L3₹1.3 Cr+₹21.6 L (19.8%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹1.3 Cr+₹21.6 L (19.8%) | L3 | Rejected-Finance Other Than Being Lowest |
| 4 | L4₹1.4 Cr+₹31.4 L (28.8%)Rejected-Finance | ₹1.4 Cr+₹31.4 L (28.8%) | L4 | Rejected-Finance Other Than Being Lowest |
| 5 | L5₹1.5 Cr+₹36.6 L (33.6%)Rejected-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | ₹1.5 Cr+₹36.6 L (33.6%) | L5 | Rejected-Finance Other Than Being Lowest |
| Sl No | Description | Qty | Unit | SHRI SAI ENTERPRISES L3 | Shetty Construction Co L6 | Chakshu Enterprise L5 | AGRAWAL ASSOCIATES L8 | R J ENTERPRISES L1 | ORIENT ELECTRIC CO L4 | ASHOK ENTERPRISES L9 | Shree Ayyappa Engineering L7 | BRITE INDUSTRIES L10 | Bob Enterprises L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00M&L for detecting leakages in water pipeline of the following sizes and rectifying the same by providing and applying required jointing—run lead joint, spigot & socket joint, flange joint, D-joint, mechanical joint etc.—including jointing material such as lead, flanges, clamps, jute, rubber gaskets, nuts, bolts, washers, grease, socket fittings, etc. Testing of the pipeline after rectification shall be carried out to the satisfaction of the Engineer-in-Charge. Notes: (a) Excavation in any type of soil/strata, cutting of RCC/PCC surface, road cutting, return filling, compaction, T&P and making good the disturbed surfaces is included in the quoted rate. (b) Testing shall be carried out in the presence of the Engineer-in-Charge. (c) The cost of joints, fittings, nuts, bolts, clamps, flanges, rubber packing, welding, D-joint of any size is included in the quoted rate. (d) Defect rectification shall be attended within 24 hours of complaint by JE E/M or Engineer-in-Charge. (e) Delay beyond 24 hours shall attract recovery @ Rs. 500 per hour. | |||||||||||||
| 1.01 | (a) For pipeline upto 25mm dia | 40 | Each Job | 500 ₹20,000 | 1,030 ₹41,200 | 980 ₹39,200 | 1,100 ₹44,000 | 740 ₹29,600 | 500 ₹20,000 | 1,060 ₹42,400 | 1,025 ₹41,000 | 1,500 ₹60,000 | 450 ₹18,000 Lowest |
| 1.02 | (b) For pipeline upto 40mm and 50 mm dia | 35 | Each Job | 1,000 ₹35,000 | 1,287.43 ₹45,060 | 1,245 ₹43,575 | 1,380 ₹48,300 | 930 ₹32,550 | 800 ₹28,000 | 1,325 ₹46,375 | 1,285.71 ₹45,000 | 1,500 ₹52,500 | 700 ₹24,500 Lowest |
| 1.03 | (c) For pipeline upto 65mm to 80 mm dia | 40 | Each Job | 1,500 ₹60,000 | 1,545 ₹61,800 | 1,510 ₹60,400 | 1,660 ₹66,400 | 1,130 ₹45,200 | 1,000 ₹40,000 | 1,595 ₹63,800 | 1,537.5 ₹61,500 | 2,500 ₹1,00,000 | 900 ₹36,000 Lowest |
| 1.04 | (d) For pipeline upto 100mm dia | 35 | Each Job | 1,700 ₹59,500 | 1,854 ₹64,890 | 1,790 ₹62,650 | 2,000 ₹70,000 | 1,340 ₹46,900 | 1,000 ₹35,000 Lowest | 1,910 ₹66,850 | 1,854.29 ₹64,900 | 3,500 ₹1,22,500 | 1,200 ₹42,000 |
| 1.05 | (e) For pipeline upto 150mm dia | 20 | Each Job | 1,900 ₹38,000 | 2,060 ₹41,200 | 1,990 ₹39,800 | 2,220 ₹44,400 | 1,490 ₹29,800 Lowest | 3,000 ₹60,000 | 2,120 ₹42,400 | 2,050 ₹41,000 | 4,500 ₹90,000 | 1,700 ₹34,000 |
| 1.06 | (f) For pipeline upto 200mm dia | 10 | Each Job | 2,000 ₹20,000 | 2,575 ₹25,750 | 2,450 ₹24,500 | 2,770 ₹27,700 | 1,840 ₹18,400 Lowest | 3,100 ₹31,000 | 2,655 ₹26,550 | 2,570 ₹25,700 | 7,500 ₹75,000 | 3,000 ₹30,000 |
| 2.00 | M&L for comprehensive maintenance of pump motors of any capacity/type installed at various locations, including connected LT panels, valves and pipelines of any size/type. Work includes daily visits, fault detection, rectification, cleaning, inspection, electrical disconnection, dismantling, repair/replacement of defective parts, re-alignment, reconnection and testing complete as directed.
Locations:
(a) INS AGNIBAHU
(b) INS ANGRE
Notes:
(1) Major Spare parts shall be measured and paid separately under respective items.
(2) Sufficient manpower for daily servicing and spares replacement (excluding Sundays) shall be part of the comprehensive maintenance schedule. Daily routine maintenance records shall be maintained in the format approved by the Engineer-in-Charge. All faults dectected shall be recorded in a register duly signed by JE, AGE and the contractor
(3) Minor consumables such as gland packing, grease, oil, nuts, bolts, washers, rubber packings, couplings, etc.shall be included in the rate quoted by the bidder
(4) Transportation of pump motors to and from the workshop (if required) shall be included in the rate quoted by the bidder. | 9 | Each job for one month | 18,000 ₹1,62,000 | 15,450 ₹1,39,050 | 14,980 ₹1,34,820 | 16,500 ₹1,48,500 | 11,230 ₹1,01,070 | 9,000 ₹81,000 Lowest | 15,920 ₹1,43,280 | 15,466 ₹1,39,194 | 15,000 ₹1,35,000 | 15,000 ₹1,35,000 |
| 3.00 | M&L for periodic and preventive service of diesel engine-driven pump (45 to 60 HP) installed at various locations, including the following works:
(a) Replacement of oil filters
(b) Replacement of air filter
(c) Replacement of fuel filter
(d) Calibration, servicing & cleaning of fuel injector pump
(e) Replacement of belt drive
(f) Replacement of engine oil and coolant
(g) Repair/service of radiator assembly
(h) Replacement of four vibration pads per diesel pump
Notes:
(1) Any parts/accessories required to make the pump functional are included in the quoted rate unless otherwise specified.
(2) Cost of dismantling and removing the diesel pump for fixing vibration pads and reconnecting with T&P is included. | 4 | Each Job | 5,000 ₹20,000 | 2,575 ₹10,300 | 2,450 ₹9,800 | 2,750 ₹11,000 | 1,840 ₹7,360 Lowest | 8,000 ₹32,000 | 2,655 ₹10,620 | 2,587 ₹10,348 | 15,000 ₹60,000 | 2,400 ₹9,600 |
| 4.00 | Attending complaints of pump motors of any capacity/make by skilled mechanic, including checking/testing of DOL/star-delta starters, relay and timer settings, NO/NC contacts, main power connections, alignment of motor & pump through level indicator, fixing cable joints, providing gland packing of suitable size, rectifying leakages by replacing flange/coupling/rubber packing/nuts/bolts, and cleaning motor to ensure satisfactory running.
Items Included in quoted rate:
(a) Minor spares: lugs, wires for starter, nuts/bolts, washers, flanges, rubber packing, gland packing, cable joints, couplings.
Service level requirement:
(a) Complaints must be attended within 24 hours.
(b) Delay beyond 24 hours shall attract recovery @ Rs. 500 per hour. | 60 | Each job | 2,500 ₹1,50,000 | 1,545 ₹92,700 | 1,495 ₹89,700 | 1,650 ₹99,000 | 1,120 ₹67,200 | 1,500 ₹90,000 | 1,590 ₹95,400 | 1,541 ₹92,460 | 5,000 ₹3,00,000 | 980 ₹58,800 Lowest |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
12 Feb 2026, 6:00 pmClosed
CWE NW MUMBAI
CWE NW MUMBAI
REPAIR/MAINT OF PUMP MOTORS OF WATER SUPPLY INST AND CERTAIN OTHER WORKS AT INS AGNRE, NOORBHOY BLDG, GODFREY CLINIC, INS TRATA WORLI, INS KUNJALI, RAFIYA MANZIL, PCDA (N), INS VAJRABAHU, B CHAWL, NS AGNIBAHU AND NGN DATA CENTRE UNDER GE (NW) KUNJALI
2026_MES_748935_1
8495/E8
Open Tender
Civil Works
Item Wise
300 days
GE NW KUNJALI
AS PER TENDER
7 documents required · 7 mandatory
₹1,000
GE NW KUNJALI
₹2.2 L
Yes
27 Mar 2026
17 Jan 2026
14 Feb 2026
17 Jan 2026
12 Feb 2026
7 Feb 2026
17 Jan 2026 - 31 Jan 2026
M&L for detecting leakages in water pipeline of the following sizes and rectifying the same by providing and applying required jointing—run lead joint, spigot & socket joint, flange joint, D-joint, mechanical joint etc.—including jointing material such as lead, flanges, clamps, jute, rubber gaskets, nuts, bolts, washers, grease, socket fittings, etc. Testing of the pipeline after rectification shall be carried out to the satisfaction of the Engineer-in-Charge. Notes: (a) Excavation in any type of soil/strata, cutting of RCC/PCC surface, road cutting, return filling, compaction, T&P and making good the disturbed surfaces is included in the quoted rate. (b) Testing shall be carried out in the presence of the Engineer-in-Charge. (c) The cost of joints, fittings, nuts, bolts, clamps, flanges, rubber packing, welding, D-joint of any size is included in the quoted rate. (d) Defect rectification shall be attended within 24 hours of complaint by JE E/M or Engineer-in-Charge. (e) Delay beyond 24 hours shall attract recovery @ Rs. 500 per hour.
(a) For pipeline upto 25mm dia
(b) For pipeline upto 40mm and 50 mm dia
(c) For pipeline upto 65mm to 80 mm dia
(d) For pipeline upto 100mm dia
(e) For pipeline upto 150mm dia
(f) For pipeline upto 200mm dia
M&L for comprehensive maintenance of pump motors of any capacity/type installed at various locations, including connected LT panels, valves and pipelines of any size/type. Work includes daily visits, fault detection, rectification, cleaning, inspection, electrical disconnection, dismantling, repair/replacement of defective parts, re-alignment, reconnection and testing complete as directed. Locations: (a) INS AGNIBAHU (b) INS ANGRE Notes: (1) Major Spare parts shall be measured and paid separately under respective items. (2) Sufficient manpower for daily servicing and spares replacement (excluding Sundays) shall be part of the comprehensive maintenance schedule. Daily routine maintenance records shall be maintained in the format approved by the Engineer-in-Charge. All faults dectected shall be recorded in a register duly signed by JE, AGE and the contractor (3) Minor consumables such as gland packing, grease, oil, nuts, bolts, washers, rubber packings, couplings, etc.shall be included in the rate quoted by the bidder (4) Transportation of pump motors to and from the workshop (if required) shall be included in the rate quoted by the bidder.
M&L for periodic and preventive service of diesel engine-driven pump (45 to 60 HP) installed at various locations, including the following works: (a) Replacement of oil filters (b) Replacement of air filter (c) Replacement of fuel filter (d) Calibration, servicing & cleaning of fuel injector pump (e) Replacement of belt drive (f) Replacement of engine oil and coolant (g) Repair/service of radiator assembly (h) Replacement of four vibration pads per diesel pump Notes: (1) Any parts/accessories required to make the pump functional are included in the quoted rate unless otherwise specified. (2) Cost of dismantling and removing the diesel pump for fixing vibration pads and reconnecting with T&P is included.
Attending complaints of pump motors of any capacity/make by skilled mechanic, including checking/testing of DOL/star-delta starters, relay and timer settings, NO/NC contacts, main power connections, alignment of motor & pump through level indicator, fixing cable joints, providing gland packing of suitable size, rectifying leakages by replacing flange/coupling/rubber packing/nuts/bolts, and cleaning motor to ensure satisfactory running. Items Included in quoted rate: (a) Minor spares: lugs, wires for starter, nuts/bolts, washers, flanges, rubber packing, gland packing, cable joints, couplings. Service level requirement: (a) Complaints must be attended within 24 hours. (b) Delay beyond 24 hours shall attract recovery @ Rs. 500 per hour.
Supply and fixing in replacement of LED indicating lamp of dia 16 mm with power consumption < 0.6W,min efficacy 120 Lmn/watt LVGP & surge protection, 64/110 Volts AC/DC / 240 Volts AC, colour Red/Green/ Yellow/Amber/Blue/White, complete all as specified and directed.
Supply and replacement of motor starter timer (suitable range as per site requirement) for pump motor starters of any capacity, complete as directed.
Supply and fixing in repairs of single-phase preventer suitable for motor up to 20 HP, complete all as specified and directed by the Engineer-in-Charge.
M&L for construction of brick masonry valve chamber (internal size 1.2 m × 1.2 m × 1.2 m) above GL by 0.30 m, suitable for installation of sluice valves of any capacity, comprising the following works: (a) 15 cm thick PCC 1:4:8 type D-2 foundation over 15 cm thick broken stone hardcore. (b) 23 cm thick brick masonry in cement mortar 1:4. (c) 15 mm thick internal and external plaster in cement mortar 1:3 including finishing the top surface smooth. (d) 5 mm thick MS plate cover mounted on 50×50×6 mm MS angle frame embedded in PCC 1:2:4 type B-1 coping. (e) Hinged rectangular opening (150 mm × 100 mm) with locking arrangement and holdfasts. (f) One coat of red oxide primer and two coats of synthetic enamel paint on steel surfaces. (g) Earthwork in excavation and return filling in any type of soil including disposal of surplus soil outside MD land. Complete all as specified and directed.
Supply and fixing in replacement a water pressure gauge, 150 mm diameter, range 0–10 kg/cm², including necessary valves, reducers, nipples and fittings to match existing installation, complete all as specified and directed. Note: Rate quoted is deemed to include adopter / ferrule / check-nut or any required accessories for proper installation.
Material and labour for spray painting pump and motor sets up to 50 HP with two coats of synthetic enamel paint over one coat of red oxide primer after complete removal of existing treatment, including writing pump name/capacity with black synthetic enamel paint, complete all as specified and directed. Note: Painting of iron base frame with dark black synthetic enamel paint is to be included in the quoted rate.
Material and labour for spray painting pump and motor sets of capacity 60 HP to 100 HP with two coats of synthetic enamel paint over one coat of red oxide primer after removal of existing treatment, including writing pump name/capacity with black synthetic enamel paint, complete all as specified and directed. Note: Painting of iron base frame with dark black synthetic enamel paint is to be included in the quoted rate.
Supply and fixing in repair of MS coupling suitable for 100 HP pump sets at various installations, complete all as specified and directed.
All as per Item No. 16.00 above but suitable for 60 HP pump sets.
All as per Item No. 16.00 above but suitable for 40 HP pump sets.
All as per Item No. 16.00 above but suitable for 20 HP pump sets.
All as per Item No. 16.00 above but suitable for 10 HP pm10p sets.
M&L for dismantling AC induction motors (single/three phase) of various capacities from the foundation, transporting burnt motor to authorised workshop, and carrying out complete rewinding and overhauling, including: (a) Opening and dismantling rotor and stator assembly. (b) Cutting and removing old burnt copper winding. (c) Cleaning stator slots using carbon tetrachloride solution. (d) Rewinding stator with super-enamelled copper winding wire of suitable gauge as per existing. (e) Applying minimum two coats of insulation varnish. (f) Heating stator assembly in heating chamber for curing and insulation improvement. (g) Assembling motor completely. (h) Transporting back to site. (i) Coupling with pump set, proper alignment. (j) Connecting LT cables, testing and commissioning. Complete all as specified and directed by Engineer-in-Charge for the following motor capacities:
125 HP capacity
100 HP capacity
75 HP Capacity
60 HP Capacity
50 HP Capacity
40 HP Capacity
30 HP Capacity
25 HP Capacity
20 HP Capacity
15 HP Capacity
10 HP Capacity
7.5 HP Capacity
5 HP Capacity
3 HP Capacity
1 HP Capacity
S&F in repair/replacement of main contactor including NO, NC connection blocks, power connectors etc suitable for following capacity of motors including taking down old one :-
75 HP motor, MNX 95, 3 pole, 415V, 50 Hz
60 HP motor,
50 HP motor, MNX 70, 3 pole, 415V, 50 Hz
40 HP motor
30 HP motor,
20 HP motor
15 HP motor,
S&F in repair/replacement of over load relay suitable for following capacity of motors including taking down old one :-
100 HP motor , Relay range (100-160 A) 415V, 50 Hz
60 HP motor , Relay range (75-100A) 415V, 50 Hz
30 HP motor , Relay range (45-70A) 415V, 50 Hz
20 HP motor , Relay range (30-40A) 415V, 50 Hz
15 HP motor , Relay range (10-25A) 415V, 50 Hz
5 HP motor , Relay range (5-10A) 415V, 50 Hz
S&F in repair/replacement of MCCBs fixed in existing panel board including taking down old one of following capacity :-
MCCB 3 Phase (TP) 200A 50Hz, 35 KA. 415V, 50 Hz, thermal magnetic adjustable type
MCCB 3 Phase (TP) 100A 50Hz, 25 KA, 415V, 50 Hz, Thermal magnetic adjustable type
MCCB 3 Phase (TP) 63A 50Hz, 25 KA, 415V, 50 Hz hermal magnetic adjustable type
MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA
MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA
M & L for replacement of unserviceable shaft sleeves for following capacity pump sets :-
Suitable for 50 HP
Suitable for 30 HP
Suitable for 15 HP
Suitable for 10HP
M & L for replacement of unserviceable impeller as per existing make and sample suitable for following capacity pump sets :-
Suitable for 100 HP
Suitable for 75 HP
Suitable for 40 HP
Suitable for 10 HP
Suitable for 30HP
Suitable for 15 HP
Suitable for 5 HP
Supply and fixing in replacement of Direct-On-Line (DOL) starter, 3-phase, 415 V, suitable for pump sets up to 5 HP capacity, complete all as specified and directed by the Engineer-in-Charge.
M&L for replacement of gland packing of suitable size for pump sets from 5 HP to 125 HP, including removing worn-out gland, cleaning, reassembling and testing the pump/motor for smooth operation, complete all as specified and directed. Note: Cost of minor consumables such as nuts, bolts, rubber packing, etc. shall be deemed to be included in the quoted rate.
Supply and fixing in repair/replacement of Star-Delta Starter suitable for 100 HP motor, 415 V, 50 Hz, complete with single phase preventor and timer, all as specified and directed.
Supply and fixing in repair/replacement of Star-Delta Starter suitable for 75 HP motor, 415 V, 50 Hz, complete with single phase preventor and timer, all as specified and directed.
Supply and fix in repair/replacement of Star Delta Starter for 50 HP Motor, 415V, 50 HZ, alongwith single phase preventor and timer complete all as specified and directed.
Supply and fix in repair/replacement of Star Delta Starter for 40 HP Motor, 415V, 50 HZ, alongwith single phase preventor and timer complete all as specified and directed.
Supply and fix in repair/replacement of Star Delta Starter for 30 HP Motor, 415V, 50 HZ alongwith single phase preventor and timer complete all as specified and directed
Supply and fix in repair/replacement of Star Delta Starter for 20 HP Motor, 415V, 50 HZ alongwith single phase preventor and timer complete all as specified and directed
Supply and fix in repair/replacement of Star Delta Starter for 15 HP Motor, 415V, 50 HZ alongwith single phase preventor and timer complete all as specified and directed
Disconnecting all electrical connections of pumpset and dismantling horizontal / vertical split casing centrifugal pump / Submersible pump of any make/model, dismantling and taking out pump shaft assembly complete for replacement of pump bearing DE or NDE, pump gasket including servicing, oiling and greasing the pumpset and assembling after replacment of defective parts and connecting to coupling testing & commissioning complete all as specified and directed for 100 HP capacities of pump motor :- (Note : Cost of transportation of pump of any capacity and make from work site to the workshop and back if required is deemed to be included in the quoted rate.)
Metalling welding, turning cutting, metal filling, preparing the pump shaft upto standard size including hardening smoothing etc and bearing housings NDE and DE side complete on lath machine as per site requirement.
Inter staging rings.(Set of two Nos)
Inter casing rings.(Set of two Nos)
Bushes Gun Metal
Bearing NDE/DE
Motor terminal plate having Nuts and bolts studs. Make TVS
Shaft sleeves mild steel.
Coupling set with nut bolt and washer.
Disconnecting all electrical connections of pumpset and dismantling horizontal / vertical split casing centrifugal pump / Submersible pump of any make/model, dismantling and taking out pump shaft assembly complete for replacement of pump bearing DE or NDE, pump gasket including servicing, oiling and greasing the pumpset and assembling after replacment of defective parts and connecting to coupling testing & commissioning complete all as specified and directed for 60 HP capacities of pump motor :- (Note : Cost of transportation of pump of any capacity and make from work site to the workshop and back if required is deemed to be included in the quoted rate.)
Metalling welding, turning cutting, preparing the pump shaft upto standard size including hardening smoothing etcand bearing housings NDE and DE side complete on lath machine as per site requirement.
Inter staging rings.(Set of two Nos)
Inter casing rings.(Set of two Nos)
Bushes Gun Metal
Bearing NDE/DE
Motor terminal plate having Nuts and bolts studs. Make TVS
Shaft sleeves mild steel.
Coupling set with nut bolt and washer.
Disconnecting all electrical connections of pumpset and dismantling horizontal / vertical split casing centrifugal pump / Submersible pump of any make/model, dismantling and taking out pump shaft assembly complete for replacement of pump bearing DE or NDE, pump gasket including servicing, oiling and greasing the pumpset and assembling after replacment of defective parts and connecting to coupling testing & commissioning complete all as specified and directed for 30 HP capacities of pump motor :- (Note : Cost of transportation of pump of any capacity and make from work site to the workshop and back if required is deemed to be included in the quoted rate.)
Metalling welding, turning cutting, preparing the pump shaft upto standard size including hardening smoothing etcand bearing housings NDE and DE side complete on lath machine as per site requirement.
Inter staging rings.(Set of two Nos)
Inter casing rings.(Set of two Nos)
Bushes Gun Metal
Bearing NDE/DE
Motor terminal plate having Nuts and bolts studs. Make TVS
Shaft sleeves mild steel.
Coupling set with nut bolt and washer.
Disconnecting all electrical connections of pumpset and dismantling horizontal / vertical split casing centrifugal pump / Submersible pump of any make/model, dismantling and taking out pump shaft assembly complete for replacement of pump bearing DE or NDE, pump gasket including servicing, oiling and greasing the pumpset and assembling after replacment of defective parts and connecting to coupling testing & commissioning complete all as specified and directed for 15 HP capacities of pump motor :- (Note : Cost of transportation of pump of any capacity and make from work site to the workshop and back if required is deemed to be included in the quoted rate.)
Metalling welding, turning cutting, preparing the pump shaft upto standard size including hardening smoothing etcand bearing housings NDE and DE side complete on lath machine as per site requirement.
Inter staging rings.(Set of two Nos)
Inter casing rings.(Set of two Nos)
Bushes Gun Metal
Bearing NDE/DE
Motor terminal plate having Nuts and bolts studs. Make TVS
Shaft sleeves mild steel.
Coupling set with nut bolt and washer.
M & L for in repair replacement of rubber coupling of centrifugal pump motor Make : FENNER/ FINOLEX of size as per Existing including testing complete all as specified and directed by Engr-in-Charge.
M & L for run lead joint in repair with pig lead including pumping out accumulated water from the leak site and necessary earth work in any type of soil,to repair the joints for following sizes of pipes :-
200 mm bore
150 mm bore
100 mm bore
S&F in repair heavy duty sluice valves (ISI marked) flanged end, cast iron body, heavy duty flanged and drilled and non rising type brass spindle with nut, long body, class PN 1.6, conforing to IS 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water all as specified and directed.
300 mm bore
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
Taking up or down, steel water tubing, and connection including cleaning for re-fixing or removal from site of work, 100 mm bore, complete all as directed.
All as per item No 43 above but here-in-before but 80 mm dia
All as per item No 43 here-in-before but 50 mm dia
All as per item No 43 here-in-before but 40 mm dia
All as per item No 43 here-in-before but 25 mm dia
All as per item No 43 here-in-before but 20 mm dia
All as per item No 43 here-in-before but 15 mm dia
Supply and fixing in repair/replacement of steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends &,laid in trenches fixed on wall with all fitting including taking down existing rusted pipes for the following sizes all as directed and specified
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
Supply and fix in repairs in existing line, gun metal gate valve (ISI marked) with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified of following sizes :-
40 mm bore
50 mm bore
25 mm bore
20 mm bore
15 mm bore
Supply and fixing in replacement of cast iron pipes with spigot and socket ends centrifugally cast heavy grade class B in any length laid in trenches of following sizes.
300mm bore
200mm bore
150mm bore
100mm bore
80mm bore
Supply and fixing in repair MS plate cover 5 mm thick for valve chamber, underground sump or overhead tank as per site requirement, including necessary fabrication work such as providing hinges, handle, locking arrangement, and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.
Taking down DI/CI specials, corroded MS sections and supplying and fixing angle iron frame of size 50 × 50 × 6 mm for valve chamber, overhead tank or underground sump, including necessary fabrication work using channel, angle or beam sections of any required size, complete all as specified and directed.
Material and labour for preparation of old painted steel/iron surfaces of any description (not otherwise described), including scraping, cleaning and applying one coat of red oxide zinc chromate primer and two coats of synthetic enamel paint of superior quality in any colour up to 150 mm dia components as specified by the user, complete all as specified and directed.
Material and labour for preparation of old painted steel/iron surfaces of any description (not otherwise described), including scraping, cleaning and applying one coat of red oxide zinc chromate primer and two coats of synthetic enamel paint of superior quality in any colour specified by the user, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation/laying of pipe etc and getting out in hard dense soil complete all as specified.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm deep as in soil complete all as specified .
Removing surplus excavated soil to a distance not exceeding 50 m and deposited where directed complete all as specified.
S&F in replacement of PVC water storage tank and fixing in position at any location and making in replacement all incoming & out going connection , provision of new tank fittings & connecting it at existing position complete all as specified and directed of following capacity :-
(a) 5000 Ltr capacity
(b) 3000 Ltr capacity
(c) 2000 Ltr capacity
(d) 1000 Ltr Capacity
(e) 10000 Ltr Capacity
(f) 500 Ltr Capacity
Supply and fix in repairs LT 1100 volts grade submersible cable, flat 6 Sqm 3 core, PVC insulated and seathed copper screen protected with multi stranded copper conductor complete all as specified and directed by Engr-in-charge.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core. laid along pole/wall/duct etc including making connection complete all as directed. Note : 1. The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
All as per item no 57 above but of size 95 sqmm 3.5 core
All as per item no 57 above but of size 50 sqmm 3.5 core
All as per item no 57 above but of size 25 sqmm 3.5 core
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 95 sq mm 3.5 core. laid in duct / along pole/wall etc including making connection complete all as directed. Note : 1. The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 70 sq mm 3.5 core. laid in duct / along pole/wall etc including making connection complete all as directed.lex Note : 1. The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 50 sq mm 3.5 core. laid in duct / along pole/wall etc including making connection complete all as directed. Note : 1. The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Taking down old unserviceable Non return valve (ISI marked), supply and installed, connecting and testing , Non return valve cast iron flanged both end connecting in line with nut bolts, rubber packing etc complete all as specified and directed by Engr- in charge of the following sizes :-
(a) 80 mm dia
(b) 100 mm dia
(c) 150 mm dia
M&L for replacement of heavy-duty brass ball-type foot valve (ISI marked), flanged end, swing-type operation conforming to IS-4038, of the following types, including provision of nuts, bolts, washers and necessary fittings, complete all as specified and directed by the Engineer-in-Charge. Note: The cost of lifting existing pipe of any size/type from the underground sump, and draining out water from the sump as required for replacement of the foot valve, shall be deemed to be included in the quoted rate.
(a) 50 mm bore
(b) 80 mm bore
(c) 100 mm bore
(d) 150 mm Bore
Supply, installation, testing and commissioning in replacement of factory-made, type-tested (CPRI certified) indoor LT feeder pillar (KIOSK) of suitable dimensions (as per Indian Electricity Rules), wall-mounted, suitable for 415 V, 3-phase, 4-wire, 50 Hz AC supply system, consisting of the following features: Bus-bar chamber with insulated copper bus bars of 400 A rating, mounted on porcelain insulators. Panel enclosure fabricated from 2 mm thick stainless steel (SS), dust and vermin proof, protection class IP-65. Double-door shutter with locking arrangement including 65 mm Godrej (Freedom) lock with two keys. Cable entry aprons and internal wiring using PVC insulated, multistranded FRLS copper conductors, IS-694 marked, minimum 4 sqmm.
COMPONENTS INCLUDED Incoming (a) Copper bus bar set, 400 A rating, four-pole (RYB & N) including PVC heat-shrink sleeves – 01 Set (b) MCCB, 4-pole, 200 A, C-curve, 415 V, rupturing capacity 16 kA, thermal-magnetic release – 01 No Outgoing (a) MCCB, 3-pole, 63 A, C-curve, 415 V, rupturing capacity 16 kA, thermal-magnetic release with adjustable overload – 03 Nos (b) MCCB, 3-pole, 40 A, C-curve, 415 V, rupturing capacity 16 kA, thermal-magnetic release with adjustable overload – 01 No (c) MCB, 2-pole, 16 A, C-curve, 10 kA, for building lighting & dosing system – 02 Nos Instrumentation Voltmeter – 03 Nos Ammeter – 03 Nos Star-Delta Starters (d) Star-Delta Starter suitable for 20 HP motor, complete with over-/under-current protection relay and automatic phase changer – 02 Nos (e) Star-Delta Starter suitable for 15 HP motor, complete with over-/under-current protection relay and automatic phase changer – 01 No Notes: Contractor shall obtain GE approval of drawings of LT feeder pillar before fabrication. Location: NMRL, FMU, INS VAJRABAHU, Fleet Office, INWTC.
Supply, fixing and testing in replacement of Entranso 2.5 three-phase sliding gate operator motor complete with electronic control unit and frequency drive suitable for gate weight up to 2500 kg, including the following accessories: (i)Remote control set with receiver (ii) Safety photocell pair (iii)3-way push button (iv)24 V DC LED flashing lamp (v) Required cable & conduit for push button, photocell, and flashing lamp Complete all as specified and directed. Note: Cost of minor spare parts and required cables is deemed to be included in the quoted rate.
Material and labour for disconnecting electric connection and taking down electric motor of capacity 2 HP to 3 HP, induction type (single/three phase), connected with exhaust blower, transporting the burnt motor to authorised workshop and carrying out the following works: (i) Opening and dismantling complete rotor and stator assembly. (ii) Removing old burnt copper winding and cleaning stator slots using carbon tetrachloride solution. (iii) Rewinding stator with super-enamelled copper winding wire of suitable gauge to match existing winding characteristics. (iv) Applying minimum two coats of insulation varnish and curing the stator assembly in heating chamber to improve insulation value. (v) Reassembling the motor, servicing blower fan, and replacing bearings. (vi) Spray painting the motor with dark grey enamel paint. (vii)Transporting back to site, coupling with blower with proper alignment. (viii) Connecting LT cables, testing and commissioning complete all as directed by the Engineer-in-Charge. Note: Cost of replacement of V-belt and other minor spare parts shall be deemed to be included in the quoted rate.
Material and labour for fixing of overhead/building roof mounted PVC tank covers of any size as per site requirement complete all as specified and directed.
Disconnecting all electrical connections of pumpset and dismantling horizontal / vertical split casing pump / Submersible pump of any make/model, dismantling and taking out pump shaft assembly complete for replacement of pump bearing DE or NDE, pump gasket including servicing, oiling and greasing the pumpset and assembling after replacment of defective parts and connecting to coupling testing & commissioning complete all as specified and directed for following sizes / capacities of pump :-
Bearing suitable for pump coupled with 100 HP motor.
Bearing suitable for pump coupled with 75 HP motor.
Bearing suitable for pump coupled with 60 HP motor.
Bearing suitable for pump coupled with 50/40 HP motor.
Bearing suitable for pump coupled with 10/12.5/ 15/ 20/ 25/ 30 HP" motor.
Bearing suitable for pump coupled with 7.5/5 HP motor.
Bearing suitable for pump coupled with any HP motor less than 05 HP
Supply, installation, replacement and testing of DIGITAL WATER LEVEL INDICATOR DEVICE operating on single-phase supply, having 150 mm direct digital display for showing water level in meter/centimeter or gallon for sumps/overhead tanks, with audio alarm for high and low levels and automatic alarm cut-off after 1 minute. The system shall comply with the following: (A) Operating Requirements (I) Device shall operate on 230 V ± 5%, with reliable digital display and alarms for low and high levels. (ii) The electronic circuit shall ensure stable and reliable operation.
(B) Construction (I) Electronic circuit housed in MS CRC sheet box, powder coated. (Ii) Box shall include nylon-moulded terminal strips for cable connections. (iii)The level sensing system shall use a resistance-type transducer unaffected by corrosion in water. (iv)Microswitch-based system only (sensor-type systems not acceptable). (v) Upper and lower level indicators shall use highly sensitive micro switches. (C) Installation Requirements The entire unit shall be mounted at Pump House, properly painted and terminated. Flexible copper control cable 0.5/1.5 sqmm, 3-core from sump/overhead tank to pump house shall be provided for interconnection. Note: GI conduit for protection of copper cable and cost of taking down existing unserviceable water level indicator shall be deemed included in the quoted rate.
Taking down old unserviceable Float valve and Supply and fix ball brass high pressure,ISI mark, with polythene float and fly nut of 50 mm dia complete screwed to iron or brass ferrule
(a) size 40 mm dia
(b) size 25 mm dia
(c) size 20 mm dia
Taking down and dismantling centrifugal pump sets of following capacity installed at various water supply installations for servicing/overhauling , greasing and replacement of worn out parts which shall be measured and paid separately under the relevant items of Sch `A' :-
Material and labour for repairing, metal filling, turning and grinding of pumpset shaft on machine for the following capacity pump sets complete all as specified and directed.
40 HP Pump set
30 HP Pump set
15 HP Pump set
20 HP Pump set
7.5/10 HP Pump set
S&F in repair for replacement of DE (Drive End) and NDE (Non-Drive End) bearing set of electric motor coupled with pump, including necessary cleaning, greasing, reassembling of motor, connecting, testing and commissioning, complete all as specified and directed, for the following capacities of motors:
Motor capacity 100 HP bearing suitable
Motor capacity 60/75/ 50/40" HP bearing
Motor capacity 15/20/25/30 HP" bearing
Motor capacity with 12.5/10/7.5/5 HP bearing
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_838730.xls
BOQ • 3.49 MB
8495.rar
Tender Documents • 3.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .