Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 CrAccepted-AOC | ₹5.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹5.8 Cr+₹39.1 L (7.27%)Rejected-AOC 62 BALSAMAND ROAD HISAR 125001 | HISAR | HARYANA | 125001 | ₹5.8 Cr+₹39.1 L (7.27%) | L2 | Rejected-AOC L2 |
| 3 | L3₹6.8 Cr+₹1.5 Cr (27.3%)Rejected-AOC | ₹6.8 Cr+₹1.5 Cr (27.3%) | L3 | Rejected-AOC L3 |
| 4 | Rejected-Technical 1804 SECTOR 2 HUDA 124001 | ROHTAK | HARYANA | 124001 | - | - | Rejected-Technical not fulfill thr criteria |
Tender Value
₹5.3 Cr
EMD Value
₹10.6 L
Closing Date
31 Mar 2022, 6:00 pmClosed
Executive Engineer
Sinchai Bhawan Jhajjar
Lying pipeline and installation of submersible pump with solor system in village Beri and Dujana District Jhajjar
2022_HRY_213953_1
Pipeline
Open Tender
Civil Works
Works
304 days
Jhajjar
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,000
₹10.6 L
Yes
Jhajjar W/S Division Jhajjar
14 May 2022
25 Mar 2022
2 Apr 2022
25 Mar 2022
31 Mar 2022
25 Mar 2022
28 Mar 2022
Amount
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressig of sides, rammng of bottoms, depth up to 1.5 m, including getting out the excavated soil and returning the soil as required in layer not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc and disposing of surplus excavated soil as directed. with in a lead of 50 m. for pipe cables etc exceding 80 mm dia but not exceding 300 mm dia as per HSR 4.16.1.2
Supply and laying pipe and specials of following dia casting along trenches and laying the same in trenches to correct alignment and gradient i/c cartage from store/railway station complete in all respect.
Laying 200 mm dia hdpe pipe as per HSR 21.96.1
Laying 200 mm dia pvc pipe 10kg pressure in borewell
Laying 100 mm dia GI pipe for delivery
Supply, erection, testing and xommissioning of submersible motor pumping set having head 30 m, 7.50 HP along with complete solar system
Boring drilling bore well of 300 mm dia for casing/strainer pipe, by suitable method prescribed in IS 2800(part-1) i/e collecting samples from different strata, preoaring and submitting strata chart/bore log i/c hiring and running charges of all equipments required for the job complete up to 90 m depth below ground level as per HSR 33.6.1.1
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means including getting out and disposal of excavated earth as directed by Engineer-In-charge. as per HSR 4.1.2.1
Providing and laying in position cement concrete 1:4:8 with 8 graded stone aggregate of 40 mm size in foundation and plinth excluding centering and shuttering complete in all respect as per HSR 6.1.6
Providing and laying in position Reinforced cement concrete 1:2:4 ( 1 cement, 2 course sand Zone -III graded stone aggregate of 20mm nominal size ) excluding cost of centering and shuttering, finishing & reinforcement up to plinth level complete as per HSR 6.14.2
Steel reinforcement of TMT bars of graded Fe-500D for RCC work, where not included in the completes rate of RCC i/c straightiening, ctting bending, placing in position, binding, wastage, overlaps and annealed steel wires etc. complete as per HSR 6.33.6 (89 kg /cum)
Air valve 65mm complete assembly HSR 20.14.1 (1 per line)
Providing & fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts & bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge HSR 20.11.4, 20.4.4 & 20.5.5
Providing and fixing of 200 mm dia MS pipe as per EL 267
Providing, lowering, laying in trenches, aligning, fixing in position and jointing at all level/depths Ductile Iron (DI) standard specials plain /flanged/ socketed confirming to IS9523-2000 with rubber ring (EPDM/SBR) joints such as tees, bends, tapers, caps etc. with in trenches in DI pipe line complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. HSR 20.68.1
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 200 MM HSR 22.162.4.1
Krishan Kumar contractor
Electro Products
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .